Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Heart Rhythm O2 ; 3(2): 169-175, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35496451

ABSTRACT

Background: Ipsilateral approach in patients requiring cardiac implantable electronic device (CIED) revision or upgrade may not be feasible, primarily due to vascular occlusion. If a new CIED is implanted on the contralateral side, a common practice is to explant the old CIED to avoid device interaction. Objective: The purpose of this study was to assess a conservative approach of abandoning the old CIED after implanting a new contralateral device. Methods: We used an artificial intelligence algorithm to analyze postimplant chest radiographs to identify those with multiple CIEDs. Outcomes of interest included device interaction, abandoned CIED elective replacement indicator (ERI) behavior, subsequent programming changes, and explant of abandoned CIED. Theoretical risk of infection with removal of abandoned CIED was estimated using a validated scoring system. Results: Among 12,045 patients, we identified 40 patients with multiple CIEDs. Occluded veins were the most common indication for contralateral implantation (n = 27 [67.5%]). Fifteen abandoned CIEDs reached ERI, with 4 reverting to VVI 65. One patient underwent explant due to device interaction, and 2 required device reprogramming. Of 32 patients with an implantable cardioverter-defibrillator, 8 (25%) had treated ventricular arrhythmia. There were no failed or inappropriate therapies due to interaction. Eighteen patients (45%) had hypothetical >1% annual risk of hospitalization for device infection if the abandoned CIED had been explanted. Conclusion: In patients requiring new CIED implant on the contralateral side, abandoning the old device is feasible. This approach may reduce the risk of infection and concerns regarding abandoned leads and magnetic resonance imaging scans. Knowledge of ERI behavior is essential to avoid device interactions.

2.
Cureus ; 12(11): e11417, 2020 Nov 10.
Article in English | MEDLINE | ID: mdl-33312813

ABSTRACT

Amplatzer Atrial Septal Occluder device has been routinely and successfully used as a percutaneous alternative to cardiac surgery for closure of atrial septal defects. It has shown to the safe with a low complication profile. Complications that most commonly occur with atrial septal defect (ASD) closure devices include malposition or embolization, residual shunt, atrial arrhythmias, thrombosis over the vena cava or atrium, erosion and perforation of the heart, and infective endocarditis. The most common complications associated with an ASD occluder device appear to be embolization and malposition with embolization usually occurring in the main pulmonary artery. We present a case in which the ASO device, AmplatzerTM (Abbott, USA), embolized into the left ventricle.

SELECTION OF CITATIONS
SEARCH DETAIL