1.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38696675

ABSTRACT

AIMS: Contact force (CF)-sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. METHODS AND RESULTS: Pulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3 mm; an inter-tag distance ≤6 mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72 h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated. CONCLUSION: A DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05752487.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Male , Female , Catheter Ablation/methods , Catheter Ablation/instrumentation , Middle Aged , Treatment Outcome , Aged , Imaging, Three-Dimensional , Cardiac Catheters , Time Factors , Equipment Design , Prospective Studies , Recurrence
2.
Heart Rhythm ; 2024 Mar 16.
Article in English | MEDLINE | ID: mdl-38499129

ABSTRACT

BACKGROUND: Ablation of accessory pathways (APs) is the cornerstone for treatment of patients with Wolff-Parkinson-White syndrome and manifestation of atrioventricular reentrant tachycardia. Pulsed field ablation (PFA) is a new type of nonthermal energy source delivered to the underlying tissue via the ablation catheter and used for ablation of arrhythmic substrates. OBJECTIVE: The purpose of this study was to determine the efficiency and long-term outcome of ablation of APs of different localizations using a focal pulsed electrical field. METHODS: Electrophysiological study was performed in patients with indication for AP ablation. An ablation catheter was used to map the position of AP insertion. Pulsed electric field was delivered through a standard ablation catheter. In left-sided APs, the first ablation attempt was within the coronary sinus (CS). Patient follow-up was scheduled 1-3 months after the ablation. Additional check-up was performed after 6 and 12 months. RESULTS: Fourteen 14 patients (3 pediatric) were treated. Termination of AP conduction was achieved in all procedures. The cohort consisted of 3 right free wall, 3 posteroseptal, and 8 left-sided APs. Ablation through CS was successfully used in 7 of 8 patients with left-sided APs. No complications were reported. Median follow-up was 5.5 months. Conduction recurrence through AP was documented in 1 patient. CONCLUSION: Focal PFA for AP shows promising results in terms of efficacy and safety. A high rate of successful termination of left-sided APs by ablation within CS may represent a new standard approach. The safety and efficacy profile of PFA seems to be transferable to the pediatric population.

3.
Europace ; 25(6)2023 06 02.
Article in English | MEDLINE | ID: mdl-37335976

ABSTRACT

AIMS: Pulsed field ablation (PFA) has emerged as a promising alternative to thermal ablation for treatment of atrial fibrillation (AF). We report performance and safety using the CENTAURI™ System (Galvanize Therapeutics) with three commercial, focal ablation catheters. METHODS AND RESULTS: ECLIPSE AF (NCT04523545) was a prospective, single-arm, multi-centre study evaluating safety and acute and chronic pulmonary vein isolation (PVI) durability using the CENTAURI System in conjunction with the TactiCath SE, StablePoint, and ThermoCool ST ablation catheters. Patients with paroxysmal or persistent AF were treated at two centres. Patients were analysed in five cohorts based upon ablation settings, catheter, and mapping system. Pulsed field ablation was performed in 82 patients (74% male, 42 paroxysmal AF). Pulmonary vein isolation was achieved in 100% of pulmonary veins (322/322) with first-pass isolation in 92.2% (297/322). There were four serious adverse events of interest (three vascular access complications and one lacunar stroke). Eighty patients (98%) underwent invasive remapping. Pulsed field ablation development Cohorts 1 and 2 showed a per-patient isolation rate of 38% and 26% and a per-PV isolation rate of 47% and 53%, respectively. Optimized PFA Cohorts 3-5 showed a per-patient isolation rate of 60%, 73%, and 81% and a per-PV isolation rate of 84%, 90%, and 92%, respectively. CONCLUSION: ECLIPSE AF demonstrated that optimized PFA using the CENTAURI System with three commercial, contact force-sensing, solid-tip focal ablation catheters resulted in transmural lesion formation and high proportion of durable PVI with a favourable safety profile, thus providing a viable treatment option for AF that integrates with contemporary focal ablation workflows.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Male , Female , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Prospective Studies , Focal Adhesions , Treatment Outcome , Catheters , Catheter Ablation/adverse effects , Catheter Ablation/methods , Pulmonary Veins/surgery , Recurrence