Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.027
Filter
1.
Acta Biomater ; 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39097126

ABSTRACT

Reactive oxygen species (ROS) are widely considered to the effective therapeutics for fighting bacterial infections especially those associated with biofilm. However, biofilm microenvironments including hypoxia, limited H2O2, and high glutathione (GSH) level seriously limit the therapeutic efficacy of ROS-based strategies. Herein, we have developed an acidic biofilm microenvironment-responsive antibacterial nanoplatform consisting of copper-dopped bovine serum albumin (CBSA) loaded with copper peroxide (CuO2) synthesized in situ and indocyanine green (ICG). The three-in-one nanotherapeutics (CuO2/ICG@CBSA) are capable of releasing Cu2+ and H2O2 in a slightly acidic environment, where Cu2+ catalyzes the conversion of H2O2 into hydroxyl radical (•OH) and consumes the highly expressed GSH to disrupt the redox homeostasis. With the assistance of an 808 nm laser, the loaded ICG not only triggers the production of singlet oxygen (1O2) by a photodynamic process, but also provides photonic hyperpyrexia that further promotes the Fenton-like reaction for enhancing •OH production and induces thermal decomposition of CuO2 for the O2-self-supplying 1O2 generation. The CuO2/ICG@CBSA with laser irradiation demonstrates photothermal-augmented multi-mode synergistic bactericidal effect and is capable of inhibiting biofilm formation and eradicating the biofilm bacteria. Further in vivo experiments suggest that the CuO2/ICG@CBSA can effectively eliminate wound infections and accelerate wound healing. The proposed three-in-one nanotherapeutics with O2/H2O2-self-supplied ROS generating capability show great potential in treating biofilm-associated bacterial infections. STATEMENT OF SIGNIFICANCE: Here, we have developed an acidic biofilm microenvironment-responsive nanoplatform consisting of copper-dopped bovine serum albumin (CBSA) loaded with copper peroxide (CuO2) synthesized in situ and indocyanine green (ICG). The nanotherapeutics (CuO2/ICG@CBSA) are capable of releasing Cu2+ and H2O2 in an acidic environment, where Cu2+ catalyzes the conversion of H2O2 into •OH and consumes the overexpressed GSH to improve oxidative stress. With the aid of an 808 nm laser, ICG provides photonic hyperpyrexia for enhancing •OH production, and triggers O2-self-supplying 1O2 generation. CuO2/ICG@CBSA with laser irradiation displays photothermal-augmented multi-mode antibacterial and antibiofilm effect. Further in vivo experiments prove that CuO2/ICG@CBSA effectively eliminates wound infection and accelerates wound healing. The proposed three-in-one nanotherapeutics show great potential in treating biofilm-associated bacterial infections.

2.
JPRAS Open ; 41: 203-214, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39050743

ABSTRACT

Introduction: Intraoperative indocyanine green fluorescence angiography (ICGFA) perfusion assessment has been demonstrated to reduce complications in reconstructive surgery. This study sought to advance ICGFA flap perfusion assessment via quantification methodologies. Method: Patients undergoing pedicled and free flap reconstruction were subjected to intraoperative ICGFA flap perfusion assessment using either an open or endoscopic system. Patient demographics, clinical impact of ICGFA and outcomes were documented. From the ICGFA recordings, fluorescence signal quality, as well as inflow/outflow milestones for the flap and surrounding (control) tissue were computationally quantified post hoc and compared on a region of interest (ROI) level. Further software development intended full flap quantification, metric computation and heatmap generation. Results: Fifteen patients underwent ICGFA assessment at reconstruction (8 head and neck, 6 breast and 1 perineum) including 10 free and 5 pedicled flaps. Visual ICGFA interpretation altered on-table management in 33.3% of cases, with flap edges trimmed in 4 and a re-anastomosis in 1 patient. One patient suffered post-operative flap dehiscence. Laparoscopic camera use proved feasible but recorded a lower quality signal than the open system.Using established and novel metrics, objective ICGFA signal ROI quantification permitted perfusion comparisons between the flap and surrounding tissue. Full flap assessment feasibility was demonstrated by computing all pixels and subsequent outputs summarisation as heatmaps. Conclusion: This trial demonstrated the feasibility and potential for ICGFA with operator based and quantitative flap perfusion assessment across several reconstructive applications. Further development and implementation of these computational methods requires technique and device standardisation.

3.
ACS Appl Mater Interfaces ; 16(28): 36142-36156, 2024 Jul 17.
Article in English | MEDLINE | ID: mdl-38968001

ABSTRACT

There is an urgent need to develop phototherapeutic agents with imaging capabilities to assess the treatment process and efficacy in real-time during cancer phototherapy for precision cancer therapy. The safe near-infrared (NIR) fluorescent dyes have garnered significant attention and are desirable for theranostics agents. However, until now, achieving excellent photostability and fluorescence (FL) imaging capability in aggregation-caused quenching (ACQ) dyes remains a big challenge. Here, for the only FDA-approved NIR dye, indocyanine green (ICG), we developed a dual-ferrocene (Fc) chimeric nanonetwork ICG@HFFC based on the rigid-flexible strategy through one-step self-assembly, which uses rigid Fc-modified hyaluronic acid (HA) copolymer (HA-Fc) and flexible octadecylamine (ODA) bonded Fc (Fc-C18) as the delivery system. HA-Fc reserved the ability of HA to target the CD44 receptor of the tumor cell surface, and the dual-Fc region provided a rigid space for securely binding ICG through metal-ligand interaction and π-π conjugation, ensuring excellent photostability. Additionally, the alkyl chain provided flexible confinement for the remaining ICG through hydrophobic forces, preserving its FL. Thereby, a balance is achieved between outstanding photostability and FL imaging capability. In vitro studies showed improved photobleaching resistance, enhanced FL stability, and increased singlet oxygen (1O2) production efficiency in ICG@HFFC. Further in vivo results display that ICG@HFFC had good tumor tracing ability and significant tumor inhibition which also exhibited good biocompatibility.. Therefore, ICG@HFFC provides an encouraging strategy to realize simultaneous enhanced tumor tracing and photothermal/photodynamic therapy (PTT/PDT) and offers a novel approach to address the limitations of ACQ dyes.


Subject(s)
Ferrous Compounds , Hyaluronic Acid , Indocyanine Green , Metallocenes , Photochemotherapy , Ferrous Compounds/chemistry , Humans , Metallocenes/chemistry , Animals , Mice , Indocyanine Green/chemistry , Indocyanine Green/therapeutic use , Indocyanine Green/pharmacology , Hyaluronic Acid/chemistry , Photothermal Therapy , Female , Fluorescent Dyes/chemistry , Fluorescent Dyes/pharmacology , Mice, Inbred BALB C , Photosensitizing Agents/chemistry , Photosensitizing Agents/pharmacology , Photosensitizing Agents/therapeutic use , Mice, Nude , Cell Line, Tumor , Neoplasms/diagnostic imaging , Neoplasms/drug therapy , Neoplasms/therapy , Neoplasms/pathology , Antineoplastic Agents/chemistry , Antineoplastic Agents/pharmacology , Antineoplastic Agents/therapeutic use , Nanoparticles/chemistry , Nanoparticles/therapeutic use
4.
Gland Surg ; 13(6): 1031-1044, 2024 Jun 30.
Article in English | MEDLINE | ID: mdl-39015719

ABSTRACT

Background: Fluorescence-guided surgery (FGS) is a cutting-edge technology that uses near-infrared (NIR) fluorescence imaging to guide surgeons in surgery. Indocyanine green (ICG) is a fluorescent dye, which can be used for in vivo imaging of tumor cells. We aimed to explore the use of ICG fluorescence-guided technology as a rapid intraoperative margin assessment method for breast cancer surgery. In addition, we also compared the dose selection of ICG. Methods: This was a non-randomized prospective cohort study. Data were collected between August 2021 and October 2022 in the Division of Breast Surgery, Department of General Surgery, Nanjing Drum Tower Hospital, the Affiliated Hospital of Medical School, Nanjing University. Upon specimen removal, tumor margins were immediately analyzed by ICG fluorescence detection and then sent to the pathology department for intraoperative frozen section analysis and subsequent routine pathological examination. Abnormal margin rates were calculated and compared using intraoperative frozen section analysis and under the guidance of ICG fluorescence. Results: The study included 69 cases of breast cancer patients who underwent tumor resection assisted by ICG fluorescence-guided technology, including 18 patients with a 0.5 mg/kg dose and 51 patients with a 1.0 mg/kg dose. According to the study findings, the ICG test achieved a sensitivity of 81.82% and a specificity of 75.82%. At a dose of 0.5 mg/kg, the sensitivity was 66.67% whereas the specificity was 93.33%. At the dose of 1 mg/kg, the sensitivity was 87.5%, and the specificity was 74.42%. Similarly, for intraoperative frozen section analysis, the sensitivity was 81.82%, but the specificity was enhanced to 94.83%. Positive surgical cut margin was not identified in 2/69 by ICG fluorescence and frozen section analysis respectively. Conclusions: The sensitivity of ICG fluorescence detection is comparable to that of frozen section analysis, but the specificity is poor. The sensitivity increased and the specificity decreased at 1 mg/kg compared to the 0.5 mg/kg dose. ICG fluorescence can be used as a supplementary tool for frozen section analysis. These findings support further development and clinical performance assessment of ICG fluorescence.

5.
Adv Tech Stand Neurosurg ; 52: 21-28, 2024.
Article in English | MEDLINE | ID: mdl-39017784

ABSTRACT

The complexity of intracranial anatomy and pathologies warrants the optimization of multimodal techniques to ensure safe and effective surgical treatment. Endoscopy is being more widely implemented in intracranial procedures as an important visualization tool, as it can offer panoramic views of deep structures while reducing the invasiveness of approaches. Fluorophores are frequently utilized to augment the identification of intracranial anatomic landmarks and pathologies. This chapter discusses the integration of these two surgical adjuncts, highlighting the key fluorophores used in endoscopic neurosurgery and their clinical applications.


Subject(s)
Fluorescent Dyes , Neuroendoscopy , Neurosurgical Procedures , Humans , Neuroendoscopy/methods , Neurosurgical Procedures/methods
6.
Khirurgiia (Mosk) ; (7): 115-123, 2024.
Article in Russian | MEDLINE | ID: mdl-39008705

ABSTRACT

OBJECTIVE: To examine the specific characteristics of ICG-angiography during various bariatric interventions. MATERIAL AND METHODS: The study included 329 patients, with 105 (32%) undergoing sleeve gastrectomy (LSG), 98 (30%) undergoing mini-gastricbypass (MGB), 126 (38%) undergoing Roux-en-Y gastric bypass (RGB). Intraoperative ICG angiography was perfomed on all patients at 'control points', the perfusion of the gastric stump was qualitatively and quantitatively assessed. RESULTS: Intraoperative ICG angiography shows that during LSG the angioarchitectonics in the area of the His angle are crucial. The presence of the posterior gastric artery of the gastric main type is a prognostically unfavorable risk factor for the development of ischemic complications. Therefore, to expand the gastric stump it is necessary to suture a 40Fr nasogastric tube and perform peritonization of the staple line. Statistical difference in blood supply at three points were found between and within the two groups of patients (Gis angle area, gastric body, pyloric region) with a p-value <0.001. During MGB, one of the important stages is applying the first (transverse) stapler cassette between the branches of the right and left gastric arteries. This maintains blood supply in anastomosis area, preventing immediate complications such as GEA failure, as well as long-term complications like atrophic gastritis, peptic ulcers, and GEA stenosis. CONCLUSION: ICG angiography is a useful method for intraoperative assessment of angioarchitecture and perfusion of the gastric stump during bariatric surgery. This helps prevent tissue ischemia and reduce the risk of early and late postoperative complications.


Subject(s)
Angiography , Bariatric Surgery , Indocyanine Green , Humans , Male , Female , Adult , Bariatric Surgery/methods , Bariatric Surgery/adverse effects , Middle Aged , Angiography/methods , Indocyanine Green/administration & dosage , Indocyanine Green/pharmacology , Gastrectomy/methods , Gastrectomy/adverse effects , Obesity, Morbid/surgery , Postoperative Complications/prevention & control , Postoperative Complications/etiology , Stomach/blood supply , Stomach/surgery , Stomach/diagnostic imaging , Gastric Artery/surgery , Monitoring, Intraoperative/methods
7.
Khirurgiia (Mosk) ; (7): 111-114, 2024.
Article in Russian | MEDLINE | ID: mdl-39008704

ABSTRACT

OBJECTIVE: To evaluate the possibility of using the method of sentinel lymph nodes (SLN) detection with indocyanine green (ICG) in patients with early breast cancer and its informativeness. MATERIAL AND METHODS: A «Determination of sentinel lymph nodes by fluorescence method intraoperatively with the use of indocyanine green¼ study, in which 168 patients are currently included, is being conducted in the clinic of the N.N. Petrov NMRC of Oncology from 2017 through the present. All patients who underwent biopsy of sentinel lymph nodes (BSLN) were primary with a T1-2N0M0 stage of process. RESULTS: The average number of axillary lymph nodes removed in BSLN was 3 (1-5). Accumulation of ICG was found in 147 (88%) patients, accumulation of labeled radiocolloid - in 137 (82%), in combination of ICG/radiocolloid - in 167 (99%) based on the results of imaging. CONCLUSION: The obtained results prove that the informativeness and relative simplicity of this method use allow its application in any hospital where breast cancer is surgically treated, as well as in the absence of radioisotopic equipment.


Subject(s)
Breast Neoplasms , Indocyanine Green , Sentinel Lymph Node Biopsy , Humans , Breast Neoplasms/surgery , Breast Neoplasms/diagnosis , Breast Neoplasms/pathology , Female , Indocyanine Green/administration & dosage , Middle Aged , Sentinel Lymph Node Biopsy/methods , Sentinel Lymph Node/pathology , Sentinel Lymph Node/surgery , Neoplasm Staging , Lymphatic Metastasis , Aged , Axilla , Adult , Lymph Node Excision/methods
8.
J Fish Dis ; : e14000, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39010687

ABSTRACT

The Strep Easy Kit, a bio-enrichment dual ICG-strip test, is a diagnostic tool designed for the detection of Streptococcus agalactiae, an important pathogenic bacterium in tilapia farming. The kit can simultaneously identify two different serotypes of S. agalactiae, serotype Ia and serotype III. This capability is crucial for the collection of valuable epidemiological data and facilitates strategic planning for effective vaccine development and deployment. The Strep Easy Kit consists of two main steps: pathogen enrichment and pathogen detection. The enrichment step increases the concentration of bacteria so that the bacterial load is raised to the level reliably detectable by the subsequent ICG strip test. This is achieved by incubating the fish samples in a suitable liquid medium under specified temperature and time conditions. The second step involves the use of the dual-ICG strip test. This strip test consists of two monoclonal antibodies and one polyclonal antibody that are specific to S. agalactiae and can distinguish between S. agalactiae serotype Ia and S. agalactiae serotype III. This dual capability enables the ICG strip test to simultaneously detect both serotypes of S. agalactiae in a single test kit. The detection limit of the test kit, which consists of a dual ICG-Strip test combined with an enrichment step, is 100 CFU/mL. The kit can be used to detect S. agalactiae in both live and dead fish samples, making it versatile for various testing scenarios. The test results obtained using the Strep Easy Kit have shown a 94.4% correlation with the standard method (Thai Agricultural Standard; TAS 10453-2010), with 90.2% sensitivity and 100% specificity. Significant advantages of the Strep Easy Kit lie in its simplicity and portability, allowing farmers to perform the test by themselves and on-site. This makes it a practical and accessible tool for the tilapia farming industry.

9.
Best Pract Res Clin Obstet Gynaecol ; : 102505, 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38964989

ABSTRACT

This literature review summarises the investigation into using Indocyanine Green (ICG) in the surgical management of endometriosis, focusing mainly on its application in Deep Endometriosis (DE). The study reviews the development, fluorescence characteristics, and clinical usage of ICG in enhancing the precision of identifying endometrial lesions during surgery. Emphasizing the technology's contribution to improved lesion visualisation, the paper discusses how ICG facilitates increased diagnostic accuracy, potentially reducing recurrence rates and the necessity for subsequent interventions. Additionally, it explores ICG's role in minimizing the risk of iatrogenic injuries, especially in ureteral endometriosis, and its utility in surgical decision-making for rectosigmoid endometriosis by evaluating bowel perfusion. Conclusively, while acknowledging the clear benefits of ICG integration in endometriosis surgical procedures, the abstract calls for more extensive research to validate its efficacy and cost-efficiency in the broader context of endometriosis treatment.

10.
Acta Biomater ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38969080

ABSTRACT

The immune system plays an important role in fracture healing, by modulating the pro-inflammatory and anti-inflammatory responses occurring instantly upon injury. An imbalance in these responses can lead to adverse outcomes, such as non-union of fractures. Implants are used to support and stabilize complex fractures. Biodegradable metallic implants offer the potential to avoid a second surgery for implant removal, unlike non-degradable implants. However, considering our dynamic immune system it is important to conduct in-depth studies on the immune response to these implants in living systems. In this study, we investigated the immune response to Mg and Mg-10Gd in vivo in a rat femur fracture model with external fixation. In vivo imaging using liposomal formulations was used to monitor the fluorescence-related inflammation over time. We combine ex vivo methods with our in vivo study to evaluate and understand the systemic and local effects of the implants on the immune response. We observed no significant local or systemic effects in the Mg-10Gd implanted group compared to the SHAM and Mg implanted groups over time. Our findings suggest that Mg-10Gd is a more compatible implant material than Mg, with no adverse effects observed in the early phase of fracture healing during our 4-week study. STATEMENT OF SIGNIFICANCE: Degradable metallic implants in form of Mg and Mg-10Gd intramedullary pins were assessed in a rat femur fracture model, alongside a non-implanted SHAM group with special respect to the potential to induce an inflammatory response. This pre-clinical study combines innovative non-invasive in vivo imaging techniques associated with multimodal, ex vivo cellular and molecular analytics. The study contributes to the development and evaluation of degradable biometals and their clinical application potential. The study results indicate that Mg-10Gd did not exhibit any significant harmful effects compared to the SHAM and Mg groups.

11.
Cancers (Basel) ; 16(14)2024 Jul 12.
Article in English | MEDLINE | ID: mdl-39061163

ABSTRACT

The standard of care approach to identify sentinel lymph nodes (SLNs) in clinically non-metastatic cutaneous melanoma patients is technetium (Tc)-based lymphoscintigraphy. This technique is associated with radiation exposure, a long intervention time, high costs, and limited availability. Indocyanine green (ICG)-based near-infrared fluorescence imaging offers a potential alternative if proven to be of comparable diagnostic accuracy. While several clinical cohorts have compared these modalities, no systematic review exists that provides a quantitative analysis of their results. Hence, a systematic literature review was conducted in December 2023 considering clinical studies comparing the diagnostic accuracy of ICG and Tc for sentinel lymph node biopsy in cutaneous melanoma patients. Three hundred nineteen studies were identified and further screened in accordance with the PRISMA 2020 guidelines, resulting in seven studies being included in the final meta-analysis. Tc identified a significantly higher number of SLNs and metastatic SLNs in prospective studies only. However, in the overall meta-analysis of all included comparative studies, no significant differences were found regarding the identification of metastatic patients or the false negative rate (FNR). ICG may be a non-inferior alternative to Tc for intraoperative guidance in sentinel lymph node biopsy in cutaneous melanoma patients. Future randomized controlled trials are needed, especially regarding the preoperative, transcutaneous identification of the affected lymph node basin.

12.
Cureus ; 16(5): e61336, 2024 May.
Article in English | MEDLINE | ID: mdl-38947581

ABSTRACT

BACKGROUND: Cervical cancer is the fourth most common cause of malignant tumor-related deaths among women in developing nations. Cervical cancer has been estimated to cause 527.600 new cases and 265.700 deaths globally per year. OBJECTIVES: This study aimed to evaluate patients with cervical cancer by ultrastaging all the lymph nodes (LN), sentinel LN (SLN) and non-SLN, to increase the sensitivity of the detection of LN metastases and the diagnostic accuracy in cervical cancer with a five-year follow-up. MATERIALS AND METHODS: This is a retrospective study of 14 cervical cancer cases from 2017 to 2019 at the Municipal Emergency Clinical Hospital of Timisoara, Romania. The cases were selected based on their high risk of LN involvement but negative intraoperative pathologic LN. After re-evaluating all paraffin block biopsy samples from 29 cases, 14 cases were included in the study, which met all criteria for ultrastaging on surgical biopsy samples. RESULTS: Patients' ages included in the study ranged from 43 to 70 years (median: 57.14 years). According to the International Federation of Gynecology and Obstetrics (FIGO) staging, the majority of the patients were in stage IB: seven cases (50%). The study revealed a positive correlation between patient age and FIGO staging, with Pearson's correlation coefficient of 0.707 and a p-value of less than 0.05, indicating that older patients were more likely to be diagnosed with a higher FIGO stage. The mean follow-up was 34.5 months, and the median follow-up was 36 months (range: 6-60 months). We obtained 167 nodes, with a mean of 11.92 nodes/case. Twenty-one LN were found to be positive with the ultrastaging method. We detected 11 LN with macrometastases (MAC) (52.38%), seven with micrometastasis (MIC) (33.3%), and three with tumor cell islets (14.4%). That would be 13% of newly diagnosed ultrastaging cases as positive nodes. This ultrastaging method detected nodal MIC in eight (57.1%) out of the 14 patients, who initially tested negative for LN involvement using the routine Hematoxylin and Eosin (HE) method. The detection of micrometastases in these patients underscored the superior sensitivity of ultrastaging, which was further highlighted by the subsequent relapse of four (28.57%) out of these eight patients. The study also found no correlation between the FIGO standardization and the number of MIC found in these patients. CONCLUSIONS: Predicting cervical LN metastasis (LNM) is crucial for improving survival rates and reducing recurrence. Very few small cohort studies used an ultrastaging method to assess non-SLNs; most of them only assessed SLNs. We showed in our study that the ultrastaging method, both in the case of SLN and non-SLN, is superior compared with H&E analysis, with a 13% rate of new positive nodule diagnosis. Metastatic involvement of non-SLN was found in over 50% of all cases (8/14) according to the ultrastaging method. Additionally, our study confirms that the sensitivity of SLN ultrastaging is high for the presence of both MIC and MAC in SLN pelvic LN. As a result, we feel that ultrastaging is the most effective method for SLN analysis in patients with early-stage cervical cancer, and bilateral detection is preferable, significantly reducing false-negative results. The routine use of SLN along with ultrastaging would lead to more accurate surgical staging and better oncological follow-up of cases.

13.
Ann Gastroenterol Surg ; 8(4): 691-700, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38957559

ABSTRACT

Aim: Laparoscopic segmentectomy (LS) using indocyanine green (ICG) fluorescence navigation with negative staining method has potential for performing accurate and safe anatomical excision. This study aimed to evaluate the significance of LS using ICG fluorescence navigation compared with open segmentectomy (OS). Methods: Eighty-seven patients who underwent anatomical segmentectomies were evaluated for OS (n = 44) and LS (n = 43). The Glissonean pedicle approach was performed using either extra- or intrahepatic method, depending on the location of segment in LS. After clamping pedicle, negative staining method was performed. Liver transection was done along intersegmental plane visualizing by overlay mode of ICG camera. Surgical outcomes were compared between two groups. Correlation between predicted resecting liver volume (PRLV) calculated using volumetry and actual resected liver volume (ARLV) was assessed in two groups. Results: Patients who underwent LS showed better outcomes in operative time, blood loss, and length of hospital stay. There were significantly fewer Grade II and Grade III or higher postoperative complications in LS group. Both values of AST (p < 0.001) and ALT (p < 0.001) on postoperative day 1 were significantly lower in LS group than in OS group. PRLV and ARLV were more strongly correlated in LS (r = 0.896) than in OS (r = 0.773). The difference between PRLV and ARLV was significantly lower in LS group than in OS group (p = 0.022), and this trend was particularly noticeable in posterosuperior segment (p = 0.008) than in anterolateral segment (p = 0.811). Conclusion: LS using ICG navigation allows precise resection and may contribute to safer short-term outcomes than OS, particularly in posterosuperior segment.

14.
Acta Biomater ; 2024 Jul 23.
Article in English | MEDLINE | ID: mdl-39053816

ABSTRACT

Indocyanine green (ICG), the only near-infrared (NIR) dye approved for clinical use, has received increasing attention as a theranostic agent wherein diagnosis (fluorescence) is combined with therapy (phototherapy), but suffers rapid hepatic clearance, poor photostability, and limited accumulation at tumor sites. Here we report that dimerized ICG can self-assemble to form zwitterionic nanoparticles (ZN-dICG), which generate fluorescence self-quenching but exhibit superior photothermal and photodynamic properties over ICG. The zwitterionic moieties confer ZN-dICG an ultralow critical micelle concentration and high colloidal stability with low non-specific binding in vivo. In addition, ZN-dICG can respond to the over-generated reactive oxygen species (ROSs) and dissociate to restore NIR fluorescence of ICG, amplifying the sensitivity via albumin binding for low-background imaging of tumors. Following systemic administration, ZN-dICG accumulated in tumors of xenograft-bearing mice for imaging primary and metastatic tumors, and induced tumor ablation under laser irradiation. The discovery of ZN-dICG would contribute to the design of translational phototheranostic platform with high biocompatibility. STATEMENT OF SIGNIFICANCE: Indocyanine green (ICG) has been extensively studied as a phototheranostic agent that combines imaging with phototherapies, but it suffers from rapid hepatic clearance, poor photostability, and limited accumulation at tumor sites. Here, we report a strategy to construct ICG dimers (ICG-tk-ICG) by conjugating two ICG molecules via a thioketal bond, which can self-assemble into zwitterionic nanoparticles (ZN-dICG) at ultralow critical micelle concentrations, exhibiting superior photothermal and photodynamic properties over ICG. ZN-dICG responds to the over-generated ROS in tumors and dissociates to restore the NIR fluorescence of ICG, enhancing the sensitivity via albumin binding for low-background imaging of tumors. This study offers a supramolecular strategy that may potentiate the clinical translation of ICG in imaging-guided cancer phototherapy.

15.
Int J Pharm ; 661: 124456, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38986962

ABSTRACT

Indocyanine green is an FDA-approved fluorescent imaging dye used for determining cardiac output, hepatic function, liver blood flow, and retinal perfusion. It has been investigated preclinically in photoacoustic imaging and photothermal therapy (PTT); however, ICG photodegradation limits its biomedical applications. An aggregated form of ICG, known as J-aggregate (IJA), exhibits superior photoacoustic signals and thermal stability than the monomeric ICG. Nevertheless, IJA still suffers from low stability in the biological milieu, and short in vivo blood circulation. To address these limitations, a range of nanocarriers have been developed to enhance IJA stability and performance. This review focuses on IJA potentials and limitations, besides the recent development of IJA-loaded nanocarriers, particularly for cancer imaging and therapy.


Subject(s)
Indocyanine Green , Theranostic Nanomedicine , Indocyanine Green/administration & dosage , Humans , Animals , Theranostic Nanomedicine/methods , Neoplasms/therapy , Neoplasms/drug therapy , Neoplasms/diagnostic imaging , Nanoparticles , Fluorescent Dyes/chemistry , Fluorescent Dyes/administration & dosage , Photoacoustic Techniques/methods , Drug Carriers/chemistry
17.
Chirurgie (Heidelb) ; 2024 Jun 11.
Article in German | MEDLINE | ID: mdl-38862785

ABSTRACT

After decades of bilateral "subtotal" and later "total" thyroidectomy, the extent of resection is now determined individually depending on the dominant thyroid condition. The leading indication by far in the study, documentation and quality center (StuDoQ) register of the Surgical Working Group Endocrinology (CAEK) is currently the suspicion of malignancy, which is followed by benign symptomatic nodular goiter, functional disorders and confirmed malignancy. The decision for an intervention as well as the extent of resection must be rigorously established. Aids for intraoperative nerve monitoring, vessel-sealing and parathyroid autofluorescence increase the safety of thyroid resections but also the complexity. The surgical technique of lobectomy using modern devices for vessel sealing is an intricate process in which the positioning, access to the neck and a modified sequence of dissection steps are equally important. While the usefulness of neuromonitoring is nowadays no longer in doubt, this is not yet so clear for other technologies. Above all, however, modern thyroid surgery is characterized by the knowledge of one's own results and a clear positioning to follow-ups. The selection of any surgical aid should be based on this knowledge.

18.
Surg Oncol ; 55: 102091, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38833894

ABSTRACT

BACKGROUND: Benign bone and soft tissue tumours encompass a broad, heterogenous range of tumours with varying clinical characteristics. These are often managed surgically with either curettage or marginal excision, but unfortunately have high rates of local recurrence. Indocyanine green (ICG) is a fluorescent dye which can be used to identify solid malignancies intraoperatively but its use is not yet established in benign bone and soft tissue tumours. This study aims to assess whether these tumours fluoresce when administered with ICG pre-operatively and whether this helps surgeons to identify tumour intra-operatively. PATIENTS AND METHODS: Patients with locally aggressive benign bone and soft tissue tumours were administered with 25-75 mg of ICG preoperatively at the induction of anaesthesia. Fluorescence was imaged intraoperatively using the Stryker SPY-PHI camera. RESULTS: Of the 12 patients included, 11 tumours fluoresced. The surgeons felt the fluorescence guided the procedure in 7 out of the 11 cases which fluoresced. It was felt to be particularly useful in the curettage of bone tumours, in which curettage could be repeated until the absence of fluorescence on imaging. After 12 months, no patients had local recurrence of the tumour. There were no adverse events recorded in this study and surgeons found the technology acceptable. CONCLUSIONS: The use of ICG for fluorescence guided surgery is a promising technology to improve outcomes of surgery for benign bone and soft tissue tumours. Further, longer term, study with a control arm is needed to identify whether it results in a reduction in the local recurrence rate.

19.
Hepatobiliary Surg Nutr ; 13(3): 494-499, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38911193

ABSTRACT

Laparoscopic anatomical hepatectomy (LAH) for patients with hepatocellular carcinoma (HCC) has been advocated by many surgeons in the hope of producing better oncological outcomes. Two recent techniques, 3D laparoscopic system and 2D real-time indocyanine green fluorescence imaging (r-ICG) guidance, are benefit for improving the operative precision of LAH in different aspects. However, these two techniques cannot be applied concomitantly because of the technical limitation. Although a new modern laparoscopic system with both 3D and indocyanine green (ICG) imaging mode has been designed, it has not been listed in many countries including China. Thus, we design a new procedure to perform the 3D LAH with 2D r-ICG guidance for HCCs with conventional laparoscopic systems. In this procedure, both 3D and 2D laparoscopic systems were used. A total of 11 patients with HCC received 3D laparoscopic right posterior sectionectomy (LRPS) with 2D r-ICG guidance. The right posterior Glissonian pedicle was clamped under the 3D vision. Then ICG solution was then intravenously administrated. The liver parenchyma was transected under the 3D vision and guided by 2D ICG vision simultaneously. There was no severe complications (Clavien-Dindo ≥III) and operation related death. The 90-day mortality was also nil. By using this procedure, the advantages of two techniques, 3D laparoscopic system and 2D r-ICG guidance, were combined so that LAH could be performed with more precision. However, it should be validated in more studies.

SELECTION OF CITATIONS
SEARCH DETAIL