Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
Add more filters











Publication year range
1.
Materials (Basel) ; 17(6)2024 Mar 08.
Article in English | MEDLINE | ID: mdl-38541399

ABSTRACT

The aim of this study was to compare the influence of heat treatment on fracture resistance (FR) of different ceramic materials used for CAD/CAM systems. METHODS: Eighty monolithic restorations were designed using the same parameters and milled with a CAD/CAM system (CEREC SW 5.0, PrimeMill, Dentsply-Sirona™, Bensheim, Germany), forming five study groups: Group 1 (n = 10), CEREC Tessera (Dentsply-Sirona™, Bensheim, Germany) crystallized (CCT), Group 2 (n = 10), CEREC Tessera uncrystallized (UCT), Group 3 (n = 20), Emax-CAD (Ivoclar Vivadent, Schaan, Liechtenstein) (CEC), Group 4 (n = 20), Vita Suprinity (Vita Zahnfabrik, Bad Säckingen, Germany) (CVS), and Group 5 (n = 20) Cameo (Aidite, Qinhuangdao, China) (CC). RESULTS: The average FR was similar for CCT, CC, and CEC at above 400 N, while CVS and UCT had the lowest values at 389,677 N and 343,212 N, respectively. CONCLUSION: Among the three ceramic materials that exhibited an FR above 400 N, CCT was considered the first recommended choice for CAD/CAM systems. This material not only demonstrated the highest FR but also exhibited outstanding consistency in the related measurements without the presence of outliers. Although the CC material showed high FR, its high dispersion revealed inconsistencies in the repetitions, suggesting caution in its use.

2.
Polymers (Basel) ; 15(5)2023 Mar 01.
Article in English | MEDLINE | ID: mdl-36904492

ABSTRACT

Additive manufacturing of composite materials is progressing in the world of 3D printing technologies; composite materials allow the combination of the physical and mechanical properties of two or more constituents to create a new material that meets the required properties of several applications. In this research, the impact of adding Kevlar® reinforcement rings on the tensile and flexural properties of the Onyx™ (nylon with carbon fibers) matrix was analyzed. Parameters such as infill type, infill density and fiber volume percentage were controlled to determine the mechanical response in tensile and flexural tests of the additive manufactured composites. The tested composites showed an increment of four times the tensile modulus and 1.4 times the flexural modulus of pure Onyx™ matrix when compared with that of the Onyx™-Kevlar®. The experimental measurements demonstrated that Kevlar® reinforcement rings can increase the tensile and flexural modulus of Onyx™-Kevlar® composites using low fiber volume percentages (lower than 19% in both samples) and 50% of rectangular infill density. However, the appearance of some defects, such as delamination, was observed and should be further analyzed to obtain products that are errorless and can be reliable for real functions as in automotive or aeronautical industries.

3.
Polymers (Basel) ; 14(20)2022 Oct 14.
Article in English | MEDLINE | ID: mdl-36297905

ABSTRACT

In this research, a three-dimensional auxetic configuration based on a known re-entrant cell is proposed. The 3D auxetic cell is configured from a new design parameter that produces an internal rotation angle to its re-entrant elements to study elastic properties in its three orthogonal directions. Through a topological analysis using Timoshenko beam theory, the bending of its re-entrant struts is modeled as a function of the new design parameter to manipulate Poisson's ratio and Young's modulus. Experimental samples were fabricated using a fused filament fabrication system using ABS and subsequently tested under quasi-static compression and bending tests. Additionally, an orthotropy factor is applied that allows for measuring the deviation between the mechanical properties of each structure. The experimental results validate the theoretical design and show that this new unit cell can transmit an orthotropic mechanical behavior to the macrostructure. In addition, the proposed structure can provide a different bending stiffness behavior in up to three working directions, which allows the application under different conditions of external forces, such as a prosthetic ankle.

4.
Materials (Basel) ; 15(5)2022 Mar 01.
Article in English | MEDLINE | ID: mdl-35269072

ABSTRACT

A three-dimensional auxetic structure based on a known planar configuration including a design parameter producing asymmetry is proposed in this study. The auxetic cell is designed by topology analysis using classical Timoshenko beam theory in order to obtain the required orthotropic elastic properties. Samples of the structure are fabricated using the ABSplus fused filament technique and subsequently tested under quasi-static compression to statistically determine the Poisson's ratio and Young's modulus. The experimental results show good agreement with the topological analysis and reveal that the proposed structure can adequately provide different elastic properties in its three orthogonal directions. In addition, three point bending tests were carried out to determine the mechanical behavior of this cellular structure. The results show that this auxetic cell influences the macrostructure to exhibit different stiffness behavior in three working directions.

5.
Heliyon ; 6(11): e05262, 2020 Nov.
Article in English | MEDLINE | ID: mdl-33204867

ABSTRACT

Some physical properties of spider silks, including mechanical strength and toughness, have been studied in many laboratories worldwide. Given that this silk is organic in nature, composed of protein, and has similar properties to metal wires or polymers, it has the potential for application in medicine, nanoelectronics, and other related areas. In this study, we worked on spider silk from the Nephila clavipes species collected from the wild and kept it in the nursery of the Autonomous University of the West, Cali, Colombia, to determine its physical, thermal, and mechanical properties, seeking possible applications in the medical and industrial sectors and comparing the material properties of the silk from the species from southwestern Colombia with those of the previously studied species from other regions. The mechanical characterization of the material was performed using a universal testing machine; thermal behavior was captured by a thermogravimetric analysis, differential scanning calorimetry, and mass spectrometry; and structural characterization was performed using diffraction X-rays. The results of the thermal characterization demonstrate that the spider silk loses 10 % of water content at 150 °C with significant changes at 400 °C, while the mechanical characterization indicates that the spider silk is much tougher than Kevlar 49 and Nylon 6 since it is capable of absorbing more energy before rupture.

6.
Materials (Basel) ; 13(22)2020 Nov 17.
Article in English | MEDLINE | ID: mdl-33213023

ABSTRACT

This work presents an elastoplastic characterization of a rolled C11000-H2 99.90% pure copper sheet considering the orthotropic non-associated Hill-48 criterion together with a modified Voce hardening law. One of the main features of this material is the necking formation at small strains levels causing the early development of non-homogeneous stress and strain patterns in the tested samples. Due to this fact, a robust inverse calibration approach, based on an experimental-analytical-numerical iterative predictor-corrector methodology, is proposed to obtain the constitutive material parameters. This fitting procedure, which uses tensile test measurements where the strains are obtained via digital image correlation (DIC), consists of three steps aimed at, respectively, determining (a) the parameters of the hardening model, (b) a first prediction of the Hill-48 parameters based on the Lankford coefficients and, (c) corrected parameters of the yield and flow potential functions that minimize the experimental-numerical error of the material response. Finally, this study shows that the mechanical characterization carried out in this context is capable of adequately predicting the behavior of the material in the bulge test.

7.
Carbohydr Polym ; 240: 116268, 2020 Jul 15.
Article in English | MEDLINE | ID: mdl-32475558

ABSTRACT

Poloxamer 407 (polox407) is widely studied as thermogelling polymer, transitioning to a gel state when warmed Polox407 forms weak hydrogels with rapid dissolution in excess solvent. This study reports the development of binary systems composed of polox407 and hydroxypropyl methylcellulose (HPMC) or sodium carboxymethylcellulose (NaCMC) aiming to improve the rheological and mechanical properties of the hydrogel. The interaction between polox407 and cellulose derivatives was studied, and their interaction with biological surfaces predicted. The carbohydrates affected the mechanical and rheological behavior of polox407 in different ways, dependent on polymer type, concentration, and temperature. Tsol/gel and rheological interaction parameters were useful to select the most suitable formulations for topical or local application. Most of the binary systems exhibited plastic behavior, thixotropy and viscoelastic properties. Appropriate formulations were identified for local application, such as 17.5/3; 17.5/4; 20/3 and 20/4 (%, w/w) for polox407/HPMC; and 17.5/1; 17.5/1.5; 20/1 and 20/1.5 (%, w/w) for polox407/NaCMC.


Subject(s)
Carboxymethylcellulose Sodium/chemistry , Hydrogels/chemistry , Hypromellose Derivatives/chemistry , Poloxamer/chemistry , Adhesiveness , Elasticity , Rheology , Temperature
8.
Polymers (Basel) ; 12(4)2020 Apr 09.
Article in English | MEDLINE | ID: mdl-32283753

ABSTRACT

The main objective of this work was to investigate the effect of hybridization on the mechanical and thermal properties of intralaminar natural fiber-reinforced hybrid composites based on sisal. Ramie, sisal and curauá fibers were selected as natural fiber reinforcements for the epoxy matrix based composites, which were produced by the hand lay-up technique. Tensile, flexural and impact tests were carried out according to American society for testing and materials (ASTM) standards to characterize the hybrid composites, while differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) were used to evaluate the thermal properties. It was found that the mechanical properties are improved by hybridization of sisal based composites. The thermal analysis showed that the hybridization did not significantly affect the thermal stability of the composites. A scanning electron microscopy (SEM) was used to examine the fracture surface of the tested specimens. The SEM images showed a brittle fracture of the matrix and fiber breakage near the matrix.

9.
Materials (Basel) ; 12(19)2019 Sep 29.
Article in English | MEDLINE | ID: mdl-31569574

ABSTRACT

This work presents an experimental and numerical analysis of the mechanical behavior of a fixed-end SAE 1045 steel cylindrical specimen during the torsion test. To this end, an iterative numerical-experimental methodology is firstly proposed to assess the material response in the tensile test using a large strain elastoplasticity-based model solved in the context of the finite element method. Then, a 3D numerical simulation of the deformation process of the torsion test is tackled with this previously characterized model that proves to be able to predict the development of a high and localized triaxial stress and strain fields caused by the presence of high levels of angular deformation. Finally, the obtained numerical results are analytically studied with the cylindrical components of the Green-Lagrange strain tensor and experimentally validated with the measurements of shear strains via Digital Image Correlation (DIC) and the corresponding torque - twist angle curve.

10.
Materials (Basel) ; 12(6)2019 Mar 18.
Article in English | MEDLINE | ID: mdl-30889796

ABSTRACT

The increase in accessibility of fused filament fabrication (FFF) machines has inspired the scientific community to work towards the understanding of the structural performance of components fabricated with this technology. Numerous attempts to characterize and to estimate the mechanical properties of structures fabricated with FFF have been reported in the literature. Experimental characterization of printed components has been reported extensively. However, few attempts have been made to predict properties of printed structures with computational models, and a lot less work with analytical approximations. As a result, a thorough review of reported experimental characterization and predictive models is presented with the aim of summarizing applicability and limitations of those approaches. Finally, recommendations on practices for characterizing printed materials are given and areas that deserve further research are proposed.

11.
Mater Sci Eng C Mater Biol Appl ; 80: 45-53, 2017 Nov 01.
Article in English | MEDLINE | ID: mdl-28866187

ABSTRACT

Hydroxyapatite-based materials have been used for dental and biomedical applications. They are commonly studied due to their favorable response presented when used for replacement of bone tissue. Those materials should be porous enough to allow cell penetration, internal tissue growth, vascular incursion and nutrient supply. Furthermore, their morphology should be designed to guide the growth of new bone tissue in anatomically applicable ways. In this work, the mechanical performance and 3D X-ray microtomography (X-ray µCT) study of a biomimetic, organic-inorganic composite material, based on hydroxyapatite, with physicochemical, structural, morphological and mechanical properties very similar to those of natural bone tissue is reported. Ceramic pieces in different shapes and several porous sizes were produced using a Modified Gel Casting Method. Pieces with a controlled and 3D hierarchical interconnected porous structure were molded by adding polymethylmethacrylate microspheres. Subsequently, they were subject to a thermal treatment to remove polymers and to promote a sinterization of the ceramic particles, obtaining a HAp scaffold with controlled porosity. Then, two different organic phases were used to generate an organic-inorganic composite material, so gelatin and collagen, which was extracted from bovine tail, were used. The biomimetic organic-inorganic composite material was characterized by Scanning Electron Microscopy, Energy Dispersive X-ray Spectroscopy, X-ray Diffraction, Fourier Transform Infrared Spectroscopy and 3D X-ray microtomography techniques. Mechanical properties were characterized in compression tests, obtaining a dramatic and synergic increment in the mechanical properties due to the chemical and physical interactions between the two phases and to the open-cell cellular behavior of the final composite material; the maximum compressive strength obtained corresponds to about 3 times higher than that reported for natural cancellous bone. The pore size distribution obtained could be capable to allow cell penetration, internal tissue in-growth, vascular incursion and nutrient supply and this material has tremendous potential for use as a replacement of bone tissue or in the manufacture and molding of prosthesis with desired shapes.


Subject(s)
Biomimetics , Animals , Biomimetic Materials , Cattle , Durapatite , Microscopy, Electron, Scanning , Porosity , Spectroscopy, Fourier Transform Infrared , Tissue Engineering , Tissue Scaffolds , X-Ray Diffraction , X-Ray Microtomography
12.
Arch. cardiol. Méx ; Arch. cardiol. Méx;86(3): 260-270, jul.-sep. 2016. tab, graf
Article in Spanish | LILACS | ID: biblio-838383

ABSTRACT

Resumen Objetivo Tras las evidencias acumuladas mediante el uso de técnicas de angioplastia con stents, surge la polémica sobre los factores que inciden en la respuesta final, ya que hay estudios que reportan reestenosis de la luz en el 30-40% alrededor de 6 meses luego de ser implantados, vinculándose como una de las causas al diseño del dispositivo. Este artículo propone la caracterización funcional de stents endovasculares, analizando su influencia mecánica en el sistema vascular y prediciendo los factores de trauma implícitos en el lecho de los vasos. Métodos Utilizando modelos computacionales de prótesis endovasculares tipo stents, mediante técnicas Finite Elements Analysis, se procedió al análisis estructural de dichos dispositivos con el fin de predecir el comportamiento mecánico y el trauma vascular. Para ello, las prótesis fueron consideradas estructuras tubulares compuestas por múltiples eslabones que están sometidos a cargas de presión, que se reflejan como concentradores de esfuerzos. Resultados El estudio permitió visualizar cómo se ajusta la geometría del stent a las diferentes cargas, obteniéndose una aproximación a la respuesta de interacción "sólido-sólido" entre el stent y la pared arterial. Así, se caracterizó el patrón de esfuerzos y se planteó un modelo conceptual que explica su incidencia mecánica en la interacción stent-vaso, para inferir en la funcionalidad del diseño del dispositivo. Conclusiones El modelo conceptual planteado permite determinar la relación entre las condiciones de interacción mecánicas del stent, y advierte sobre los efectos en lo que sería la operación del dispositivo en el ambiente vascular.


Abstract Objective The accumulated evidence on angioplasty techniques with stents has raised a controversy about the factors that influence the final vascular response. Indeed, several studies have shown there might be re-stenosis between 30% to 40% about 6 months after placement, relating to the design of the device as one of the main causes. This paper proposes the functional characterization of endovascular stents, analyzing its mechanical influence in the vascular system and predicting implicit traumatic factors in the vessel. Methods A structural analysis was made for several computational models of endovascular stents using Finite Element Analysis in order to predict the mechanical behavior and the vascular trauma. In this way, the stents were considered as tubular devices composed of multiple links under radial pressure loads, reflecting stress concentration effects. Results The analysis allowed to visualize how the geometry of stents is adjusted under several load conditions, in order to obtain the response of "solid-solid" interaction between the stent and the arterial wall. Thus, an analysis was performed in order to calculate stress, and a conceptual model that explains its mechanical impact on the stent-vessel interaction, was raised, to infer on the functionality from the design of the devices. Conclusions The proposed conceptual model allows to determine the relationship between the conditions of mechanical interaction of the stents, and warns about the effects in what would be the operation of the device on the vascular environment.


Subject(s)
Humans , Blood Vessels/injuries , Stents/adverse effects , Finite Element Analysis , Models, Cardiovascular , Biomechanical Phenomena
13.
Arch Cardiol Mex ; 86(3): 260-70, 2016.
Article in Spanish | MEDLINE | ID: mdl-27238950

ABSTRACT

OBJECTIVE: The accumulated evidence on angioplasty techniques with stents has raised a controversy about the factors that influence the final vascular response. Indeed, several studies have shown there might be re-stenosis between 30% to 40% about 6 months after placement, relating to the design of the device as one of the main causes. This paper proposes the functional characterization of endovascular stents, analyzing its mechanical influence in the vascular system and predicting implicit traumatic factors in the vessel. METHODS: A structural analysis was made for several computational models of endovascular stents using Finite Element Analysis in order to predict the mechanical behavior and the vascular trauma. In this way, the stents were considered as tubular devices composed of multiple links under radial pressure loads, reflecting stress concentration effects. RESULTS: The analysis allowed to visualize how the geometry of stents is adjusted under several load conditions, in order to obtain the response of "solid-solid" interaction between the stent and the arterial wall. Thus, an analysis was performed in order to calculate stress, and a conceptual model that explains its mechanical impact on the stent-vessel interaction, was raised, to infer on the functionality from the design of the devices. CONCLUSIONS: The proposed conceptual model allows to determine the relationship between the conditions of mechanical interaction of the stents, and warns about the effects in what would be the operation of the device on the vascular environment.


Subject(s)
Blood Vessels/injuries , Finite Element Analysis , Models, Cardiovascular , Stents/adverse effects , Biomechanical Phenomena , Humans
14.
J Mech Behav Biomed Mater ; 61: 36-44, 2016 08.
Article in English | MEDLINE | ID: mdl-26826765

ABSTRACT

This work presents the modeling and simulation of the mechanical response of a Dacron graft in the pressurization test and its clinical application in the analysis of an end-to-end anastomosis. Both problems are studied via an anisotropic constitutive model that was calibrated by means of previously reported uniaxial tensile tests. First, the simulation of the pressurization test allows the validation of the experimental material characterization that included tests carried out for different levels of axial stretching. Then, the analysis of an end-to-end anastomosis under an idealized geometry is proposed. This case consists in evaluating the mechanical performance of the graft together with the stresses and deformations in the neighborhood of the Dacron with the artery. This research contributes important data to understand the functioning of the graft and the possibility of extending the analysis to complex numerical cases like its insertion in the aortic arch.


Subject(s)
Blood Vessel Prosthesis , Polyethylene Terephthalates/chemistry , Stress, Mechanical , Anastomosis, Surgical , Anisotropy , Aorta, Thoracic , Biomechanical Phenomena , Computer Simulation , Humans
SELECTION OF CITATIONS
SEARCH DETAIL