Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters











Database
Language
Publication year range
1.
Nanotechnology ; 35(42)2024 Aug 02.
Article in English | MEDLINE | ID: mdl-39059417

ABSTRACT

The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), etiological agent for the coronavirus disease 2019 (COVID-19), has resulted in over 775 million global infections. Early diagnosis remains pivotal for effective epidemiological surveillance despite the availability of vaccines. Antigen-based assays are advantageous for early COVID-19 detection due to their simplicity, cost-effectiveness, and suitability for point-of-care testing (PoCT). This study introduces a graphene field-effect transistor-based biosensor designed for high sensitivity and rapid response to the SARS-CoV-2 spike protein. By functionalizing graphene with monoclonal antibodies and applying short-duration gate voltage pulses, we achieve selective detection of the viral spike protein in human serum within 100 µs and at concentrations as low as 1 fg ml-1, equivalent to 8 antigen molecules perµl of blood. Furthermore, the biosensor estimates spike protein concentrations in serum from COVID-19 patients. Our platform demonstrates potential for next-generation PoCT antigen assays, promising fast and sensitive diagnostics for COVID-19 and other infectious diseases.


Subject(s)
Biosensing Techniques , COVID-19 , Graphite , SARS-CoV-2 , Spike Glycoprotein, Coronavirus , Transistors, Electronic , Spike Glycoprotein, Coronavirus/analysis , Spike Glycoprotein, Coronavirus/immunology , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Graphite/chemistry , Humans , SARS-CoV-2/isolation & purification , SARS-CoV-2/immunology , COVID-19/diagnosis , COVID-19/blood , COVID-19/virology , Sensitivity and Specificity , Antibodies, Monoclonal/immunology , Antibodies, Monoclonal/chemistry
2.
Nanomaterials (Basel) ; 12(18)2022 Sep 16.
Article in English | MEDLINE | ID: mdl-36145010

ABSTRACT

Graphene field-effect transistors (GFETs) exhibit unique switch and sensing features. In this article, GFETs are investigated within the tight-binding formalism, including quantum capacitance correction, where the graphene ribbons with reconstructed armchair edges are mapped into a set of independent dual channels through a unitary transformation. A new transfer matrix method is further developed to analyze the electron transport in each dual channel under a back gate voltage, while the electronic density of states of graphene ribbons with transversal dislocations are calculated using the retarded Green's function and a novel real-space renormalization method. The Landauer electrical conductance obtained from these transfer matrices was confirmed by the Kubo-Greenwood formula, and the numerical results for the limiting cases were verified on the basis of analytical results. Finally, the size- and gate-voltage-dependent source-drain currents in GFETs are calculated, whose results are compared with the experimental data.

3.
Mikrochim Acta ; 189(3): 127, 2022 03 01.
Article in English | MEDLINE | ID: mdl-35233646

ABSTRACT

Smart electronic devices based on micro-controllers, also referred to as fashion electronics, have raised wearable technology. These devices may process physiological information to facilitate the wearer's immediate biofeedback in close contact with the body surface. Standard market wearable devices detect observable features as gestures or skin conductivity. In contrast, the technology based on electrochemical biosensors requires a biomarker in close contact with both a biorecognition element and an electrode surface, where electron transfer phenomena occur. The noninvasiveness is pivotal for wearable technology; thus, one of the most common target tissues for real-time monitoring is the skin. Noninvasive biosensors formats may not be available for all analytes, such as several proteins and hormones, especially when devices are installed cutaneously to measure in the sweat. Processes like cutaneous transcytosis, the paracellular cell-cell unions, or even reuptake highly regulate the solutes content of the sweat. This review discusses recent advances on wearable devices based on electrochemical biosensors for biomarkers with a complex blood-to-sweat partition like proteins and some hormones, considering the commented release regulation mechanisms to the sweat. It highlights the challenges of wearable epidermal biosensors (WEBs) design and the possible solutions. Finally, it charts the path of future developments in the WEBs arena in converging/emerging digital technologies.


Subject(s)
Biosensing Techniques , Wearable Electronic Devices , Biomarkers/analysis , Hormones/analysis , Sweat/chemistry
4.
Biosens Bioelectron ; 157: 112167, 2020 Jun 01.
Article in English | MEDLINE | ID: mdl-32250937

ABSTRACT

Graphene-based transistors are promising devices in the evaluation of carrier density in biological analytes. We report on the design and fabrication of a graphene-based field-effect transistor for monitoring and assessing the interaction between the coagulation factors based on the charge carrier density in a blood sample. When biochemical reactions occurred during the coagulation cascade process, a dopant effect was noticed on the graphene surface by the change in Dirac point voltage values. Additional experiments were performed using blood samples treated with activators (vitamin K, calcium chloride, and thromboplastin reagent) and inhibitors (heparin drugs) to evaluate the selectivity of the graphene field-effect transistor devices. Since the transfer characteristic curves presented divergent behaviours for different levels of procoagulants and anticoagulants, the measurements showed that the devices can assess changes in the concentrations of factors that inhibit or accelerate the cascade process when using untreated and treated samples. Reproducibility was verified by testing samples from different sources. To the best of our knowledge, this study is the first to demonstrate the potential of graphene in monitoring the hemostasis process through the analysis of the electrical properties of human whole blood.


Subject(s)
Biosensing Techniques/instrumentation , Blood Coagulation , Graphite/chemistry , Transistors, Electronic , Anticoagulants/pharmacology , Blood Coagulation/drug effects , Blood Coagulation Tests/instrumentation , Coagulants/pharmacology , Equipment Design , Hemostasis/drug effects , Humans
5.
Nano Lett ; 17(10): 5938-5949, 2017 10 11.
Article in English | MEDLINE | ID: mdl-28895736

ABSTRACT

Electrically active field-effect transistors (FET) based biosensors are of paramount importance in life science applications, as they offer direct, fast, and highly sensitive label-free detection capabilities of several biomolecules of specific interest. In this work, we report a detailed investigation on surface functionalization and covalent immobilization of biomarkers using biocompatible ethanolamine and poly(ethylene glycol) derivate coatings, as compared to the conventional approaches using silica monoliths, in order to substantially increase both the sensitivity and molecular selectivity of nanowire-based FET biosensor platforms. Quantitative fluorescence, atomic and Kelvin probe force microscopy allowed detailed investigation of the homogeneity and density of immobilized biomarkers on different biofunctionalized surfaces. Significantly enhanced binding specificity, biomarker density, and target biomolecule capture efficiency were thus achieved for DNA as well as for proteins from pathogens. This optimized functionalization methodology was applied to InP nanowires that due to their low surface recombination rates were used as new active transducers for biosensors. The developed devices provide ultrahigh label-free detection sensitivities ∼1 fM for specific DNA sequences, measured via the net change in device electrical resistance. Similar levels of ultrasensitive detection of ∼6 fM were achieved for a Chagas Disease protein marker (IBMP8-1). The developed InP nanowire biosensor provides thus a qualified tool for detection of the chronic infection stage of this disease, leading to improved diagnosis and control of spread. These methodological developments are expected to substantially enhance the chemical robustness, diagnostic reliability, detection sensitivity, and biomarker selectivity for current and future biosensing devices.


Subject(s)
Antigens, Protozoan/analysis , Biosensing Techniques/instrumentation , Chagas Disease/diagnosis , Nanowires/chemistry , Trypanosoma cruzi/isolation & purification , Antibodies, Immobilized/chemistry , Antigens, Protozoan/genetics , Biomarkers/analysis , Biosensing Techniques/methods , Chagas Disease/parasitology , DNA/analysis , DNA/genetics , Equipment Design , Humans , Indium/chemistry , Models, Molecular , Phosphines/chemistry , Surface Properties , Transistors, Electronic , Trypanosoma cruzi/genetics
6.
Sensors (Basel) ; 11(10): 9442-9, 2011.
Article in English | MEDLINE | ID: mdl-22163704

ABSTRACT

Separative extended gate field effect transistor (SEGFET) type devices have been used as an ion sensor or biosensor as an alternative to traditional ion sensitive field effect transistors (ISFETs) due to their robustness, ease of fabrication, low cost and possibility of FET isolation from the chemical environment. The layer-by-layer technique allows the combination of different materials with suitable properties for enzyme immobilization on simple platforms such as the extended gate of SEGFET devices enabling the fabrication of biosensors. Here, glucose biosensors based on dendrimers and metallophthalocyanines (MPcs) in the form of layer-by-layer (LbL) films, assembled on indium tin oxide (ITO) as separative extended gate material, has been produced. NH(3)(+) groups in the dendrimer allow electrostatic interactions or covalent bonds with the enzyme (glucose oxidase). Relevant parameters such as optimum pH, buffer concentration and presence of serum bovine albumin (BSA) in the immobilization process were analyzed. The relationship between the output voltage and glucose concentration shows that upon detection of a specific analyte, the sub-products of the enzymatic reaction change the pH locally, affecting the output signal of the FET transducer. In addition, dendritic layers offer a nanoporous environment, which may be permeable to H(+) ions, improving the sensibility as modified electrodes for glucose biosensing.


Subject(s)
Biosensing Techniques/instrumentation , Dendrimers/chemistry , Glucose/analysis , Indoles/chemistry , Nickel/chemistry , Transistors, Electronic , Aspergillus niger/enzymology , Aziridines/chemistry , Buffers , Glucose Oxidase/metabolism , Hydrogen-Ion Concentration , Isoindoles , Recycling
SELECTION OF CITATIONS
SEARCH DETAIL