1.
J Pers Med ; 11(5)2021 Apr 24.
Article in English | MEDLINE | ID: mdl-33923312

ABSTRACT

Intravenous ports serve as vascular access and are indispensable in cancer treatment. Most studies are not based on a systematic and standardized approach. Hence, the aim of this study was to demonstrate long-term results of port implantation following a standard algorithm. A total of 2950 patients who underwent intravenous port implantation between March 2012 and December 2018 were included. Data of patients managed following a standard algorithm were analyzed for safety and long-term outcomes. The cephalic vein was the predominant choice of entry vessel. In female patients, wire assistance without use of puncture sheath was less likely and echo-guided puncture via internal jugular vein (IJV) with use of puncture sheath was more likely to be performed, compared to male patients (p < 0.0001). The procedure-related complication rate was 0.07%, and no pneumothorax, hematoma, catheter kinking, catheter fracture, or pocket erosion was reported. Catheter implantations by echo-guided puncture via IJV notably declined from 4.67% to 0.99% (p = 0.027). Mean operative time gradually declined from 37.88 min in 2012 to 23.20 min in 2018. The proposed standard algorithm for port implantation reduced the need for IJV echo-guided approach and eliminated procedure-related catastrophic complications. In addition, it shortened operative time and demonstrated good functional results.

2.
J Biomed Mater Res B Appl Biomater ; 106(3): 1017-1027, 2018 04.
Article in English | MEDLINE | ID: mdl-28480604

ABSTRACT

All available conventional ports share a common design, including catheter, locking nut, and port body, and all share two sites of structural weakness. One site is the junction between the locking nut and the proximal end of the catheter. The other site is the catheter fixation site between the locking nut and the protruding stud of the connecting tube. To overcome these shortcomings, we designed a new type of intravenous port which combines the connecting tube into one piece. The aims of this study were to test the mechanical characteristics of the new design and assess its safety in animal study. The prototype of the preattached port was manufactured from biocompatible materials, including PEEK, silicone and polyurethane. All components were assembled with biocompatible glue and mechanical and safety tests were performed to determine the mechanical strength, and tissue reaction of surrounding soft tissue and entry vessels. The mechanical tests showed the new design would not lead to catheter fracture in the oscillation test. The traction test showed significant peak load (18.75 ± 3.29 vs. 26.61 ± 1.75 N; p = 0.036) because of the difference in catheter extension capacity (26.57 ± 4.28 vs. 47.93 ± 2.45 mm; p = 0.012). Significantly smaller endurable injection pressure was identified in the prototype. (90 ± 20 vs. 177.5± 9.48 psi; p = 0.01) The safety test showed good tolerance in beagle dogs and led to no intravascular thrombus and minimal reaction in surrounding tissues. The new prototype preattached port showed good mechanical strength and overcame two potential structural weakness points. The integrated fixation design not only reduced the dimensions of the port device but also provided a greater injection area compared to current designs. It did not cause intravascular thrombosis and produced minimal tissue reaction in surrounding soft tissue, as identified by autopsy. The new design of the fixation device could serve as the basis for the next generation of intravenous ports. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1017-1027, 2018.


Subject(s)
Equipment Design/methods , Vascular Access Devices , Anesthesia/methods , Animals , Blood Vessels/physiology , Catheters , Dogs , Equipment Failure , Injections , Mechanical Phenomena , Pressure , Vascular Access Devices/adverse effects