Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Micromachines (Basel) ; 14(11)2023 Oct 30.
Article in English | MEDLINE | ID: mdl-38004883

ABSTRACT

Tunable fiber lasers have the advantages of good beam quality, high integration, and adjustable output wavelength, and they are widely used in fields such as optical fiber communication and optical fiber sensing. The fiber filter is one of the key components of tunable fiber lasers. Among the various filters currently used, multimode interference filters have the advantages of simple structure, convenient implementation, flexible tuning methods, and convenient spectral range design. The structures of multimode interference filters based on multimode fibers, no-core fibers, multi-core fibers, tapered fibers, and other special fibers are introduced in this paper. The working principles and tuning methods are analyzed and the research progress of tunable fiber lasers based on these filters is summarized. Finally, the development trend of tunable fiber lasers based on multimode interference filters is discussed. The rapid development and applications of multimode interference filters can help improve the performance of continuous and pulse lasers as well as promote the practicality of tunable fiber lasers.

2.
Sensors (Basel) ; 23(6)2023 Mar 09.
Article in English | MEDLINE | ID: mdl-36991701

ABSTRACT

In this study, we developed a glucose fiber sensor incorporating heterodyne interferometry to measure the phase difference produced by the chemical reaction between glucose and glucose oxidase (GOx). Both theoretical and experimental results showed that the amount of phase variation is inversely proportional to glucose concentration. The proposed method provided a linear measurement range of the glucose concentration from 10 mg/dL to 550 mg/dL. The experimental results indicated that the sensitivity is proportional to the length of the enzymatic glucose sensor, and the optimum resolution can be obtained at a sensor length of 3 cm. The optimum resolution of the proposed method is better than 0.6 mg/dL. Moreover, the proposed sensor demonstrates good repeatability and reliability. The average relative standard deviation (RSD) is better than 10% and satisfied the minimum requirement for point-of-care devices.


Subject(s)
Glucose , Optical Fibers , Reproducibility of Results , Interferometry , Glucose Oxidase
3.
Materials (Basel) ; 15(21)2022 Oct 24.
Article in English | MEDLINE | ID: mdl-36363041

ABSTRACT

The measurement of pH has received great attention in diverse fields, such as clinical diagnostics, environmental protection, and food safety. Optical fiber sensors are widely used for pH sensing because of their great advantages. In this work, an optical fiber pH sensor is fabricated, by combining the merits of the multimode interference configuration and pH-sensitive polyaniline/polyacrylic acid (PAni/PAA) coatings, which was successfully in situ deposited on the no-core fiber (NCF) by the layer-by-layer (LBL) self-assembly method. The sensors' performance was experimentally characterized when used for pH detection. It has a high sensitivity of 0.985 nm/pH and a great linear response in a universal pH range of 2-12. The response time and recovery time is measured to be less than 10 s. In addition, its temperature sensitivity is tested to be about 0.01 nm/°C with a low temperature crosstalk effect, which makes it promising for detecting pH in the liquid phase with temperature variation. The sensors also demonstrated easy fabrication, good stability, and repeatability, which are adapted to pH detection in most practical applications.

4.
Mikrochim Acta ; 189(9): 321, 2022 08 06.
Article in English | MEDLINE | ID: mdl-35932379

ABSTRACT

The label-free detection of SARS-CoV-2 spike protein is demonstrated by using slightly tapered no-core fiber (ST-NCF) functionalized with ACE2. In the fabricated sensor head, abrupt changes in the mode-field diameter at the interfaces between single-mode fiber and no-core fiber excite multi-guided modes and facilitate multi-mode interference (MMI). Its slightly tapered region causes the MMI to be more sensitive to the refractive index (RI) modulation of the surrounding medium. The transmission minimum of the MMI spectrum was selected as a sensor indicator. The sensor surface was functionalized with ACE2 bioreceptors through the pretreatment process. The ACE2-immobilized ST-NCF sensor head was exposed to the samples of SARS-CoV-2 spike protein with concentrations ranging from 1 to 104 ng/mL. With increasing sample concentration, we observed that the indicator dip moved towards a longer wavelength region. The observed spectral shifts are attributed to localized RI modulations at the sensor surface, which are induced by selective bioaffinity binding between ACE2 and SARS-CoV-2 spike protein. Also, we confirmed the capability of the sensor head as an effective and simple optical probe for detecting antigen protein samples by applying saliva solution used as a measurement buffer. Moreover, we compared its detection sensitivity to SARS-CoV-2 and MERS-CoV spike protein to examine its cross-reactivity. In particular, we proved the reproducibility of the bioassay protocol adopted here by employing the ST-NCF sensor head reconstructed with ACE2. Our ST-NCF transducer is expected to be beneficially utilized as a low-cost and portable biosensing platform for the rapid detection of SARS-CoV-2 spike protein.


Subject(s)
COVID-19 , Spike Glycoprotein, Coronavirus , Angiotensin-Converting Enzyme 2 , COVID-19/diagnosis , Humans , Reproducibility of Results , SARS-CoV-2 , Spike Glycoprotein, Coronavirus/metabolism , Transducers
5.
Sensors (Basel) ; 22(12)2022 Jun 14.
Article in English | MEDLINE | ID: mdl-35746262

ABSTRACT

Liquid-level sensors are required in modern industrial and medical fields. Optical liquid-level sensors can solve the safety problems of traditional electrical sensors, which have attracted extensive attention in both academia and industry. We propose a distributed liquid-level sensor based on optical frequency domain reflectometry and with no-core fiber. The sensing mechanism uses optical frequency domain reflectometry to capture the strong reflection of the evanescent field of the no-core fiber at the liquid-air interface. The experimental results show that the proposed method can achieve a high resolution of 0.1 mm, stability of ±15 µm, a relatively large measurement range of 175 mm, and a high signal-to-noise ratio of 30 dB. The sensing length can be extended to 1.25 m with a weakened signal-to-noise ratio of 10 dB. The proposed method has broad development prospects in the field of intelligent industry and extreme environments.

6.
Sensors (Basel) ; 19(7)2019 Apr 10.
Article in English | MEDLINE | ID: mdl-30974912

ABSTRACT

We have proposed a novel tapered-single mode-no core-single mode (TSNS) fiber refractometer based on multimode interference. The TSNS structure exhibits a high contrast ratio (>15 dB) and a uniform interference fringe. The influence of different lengths and diameters of the TSNS on the refractive index unit (RIU) sensitivity was investigated. The experimental investigations indicated a maximum sensitivity of 1517.28 nm/RIU for a refractive index of 1.417 and low-temperature sensitivity (<10 pm/ºC). The experimental and simulation results are also in good agreement.

7.
Sensors (Basel) ; 17(10)2017 Oct 16.
Article in English | MEDLINE | ID: mdl-29035290

ABSTRACT

A relative humidity (RH) sensor based on single-mode-no-core-single-mode fiber (SNCS) structure is proposed and experimentally demonstrated. The agarose gel is coated on the no-core fiber (NCF) as the cladding, and multimode interference (MMI) occurs in the SNCS structure. The transmission spectrum of the sensor is modulated at different ambient relative humidities due to the tunable refractive index property of the agarose gel film. The relative humidity can be measured by the wavelength shift and intensity variation of the dip in the transmission spectra. The humidity response of the sensors, coated with different concentrations and coating numbers of the agarose solution, were experimentally investigated. The wavelength and intensity sensitivity is obtained as -149 pm/%RH and -0.075 dB/%RH in the range of 30% RH to 75% RH, respectively. The rise and fall time is tested to be 4.8 s and 7.1 s, respectively. The proposed sensor has a great potential in real-time RH monitoring.

8.
Sensors (Basel) ; 17(9)2017 Sep 18.
Article in English | MEDLINE | ID: mdl-28926998

ABSTRACT

This paper presents a new hydrogen sensor based on a single mode-no core-single mode (SNS) fiber interferometer structure. The surface of the no core fiber (NCF) was coated by Pd/WO3 film to detect the variation of hydrogen concentration. If the hydrogen concentration changes, the refractive index of the Pd/WO3 film as well as the boundary condition for light propagating in the NCF will all be changed, which will then cause a shift into the resonant wavelength of interferometer. Therefore, the hydrogen concentration can be deduced by measuring the shift of the resonant wavelength. Experimental results demonstrated that this proposed sensor had a high detection sensitivity of 1.26857 nm/%, with good linearity and high accuracy (maximum 0.0055% hydrogen volume error). Besides, it also possessed the advantages of simple structure, low cost, good stability, and repeatability.

9.
Sensors (Basel) ; 17(6)2017 Jun 16.
Article in English | MEDLINE | ID: mdl-28621742

ABSTRACT

A high sensitivity refractive index sensor based on a single mode-small diameter no core fiber structure is proposed. In this structure, a small diameter no core fiber (SDNCF) used as a sensor probe, was fusion spliced to the end face of a traditional single mode fiber (SMF) and the end face of the SDNCF was coated with a thin film of gold to provide reflective light. The influence of SDNCF diameter and length on the refractive index sensitivity of the sensor has been investigated by both simulations and experiments, where results show that the diameter of SDNCF has significant influence. However, SDNCF length has limited influence on the sensitivity. Experimental results show that a sensitivity of 327 nm/RIU (refractive index unit) has been achieved for refractive indices ranging from 1.33 to 1.38, which agrees well with the simulated results with a sensitivity of 349.5 nm/RIU at refractive indices ranging from 1.33 to 1.38.

SELECTION OF CITATIONS
SEARCH DETAIL