Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.501
Filter
2.
JACC Cardiovasc Interv ; 17(13): 1533-1543, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38986653

ABSTRACT

BACKGROUND: Randomized controlled trials (RCTs) examining the outcomes with limus drug-coated balloons (DCBs) vs paclitaxel DCBs were small and underpowered for clinical endpoints. OBJECTIVES: This study sought to compare the angiographic and clinical outcomes with limus DCBs vs paclitaxel DCBs for percutaneous coronary intervention (PCI). METHODS: An electronic search of Medline, EMBASE, and Cochrane databases was performed through January 2024 for RCTs comparing limus DCBs vs paclitaxel DCBs for PCI. The primary endpoint was clinically driven target lesion revascularization (TLR). The secondary endpoints were late angiographic findings. Summary estimates were constructed using a random effects model. RESULTS: Six RCTs with 821 patients were included; 446 patients received a limus DCB, and 375 patients received a paclitaxel DCB. There was no difference between limus DCBs and paclitaxel DCBs in the incidence of TLR at a mean of 13.4 months (10.3% vs 7.8%; risk ratio [RR]: 1.32; 95% CI: 0.84-2.08). Subgroup analysis suggested no significant interaction among studies for de novo coronary lesions vs in-stent restenosis (Pinteraction = 0.58). There were no differences in the risk of major adverse cardiovascular events, cardiac mortality, or target vessel myocardial infarction between groups. However, limus DCBs were associated with a higher risk of binary restenosis (RR: 1.89; 95% CI: 1.14-3.12), late lumen loss (mean difference = 0.16; 95% CI: 0.03-0.28), and a smaller minimum lumen diameter (mean difference = -0.12; 95% CI: -0.22 to -0.02) at late follow-up. In addition, late lumen enlargement occurred more frequently (50% vs 27.5%; RR: 0.59; 95% CI: 0.45-0.77) with paclitaxel DCBs. CONCLUSIONS: Among patients undergoing DCB-only PCI, there were no differences in the risk of clinically driven TLR and other clinical outcomes between limus DCBs and paclitaxel DCBs. However, paclitaxel DCBs were associated with better late angiographic outcomes. These findings support the need for future trials to establish the role of new-generation limus DCBs for PCI.


Subject(s)
Angioplasty, Balloon, Coronary , Cardiac Catheters , Cardiovascular Agents , Coated Materials, Biocompatible , Coronary Artery Disease , Paclitaxel , Percutaneous Coronary Intervention , Aged , Female , Humans , Male , Middle Aged , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/mortality , Cardiovascular Agents/administration & dosage , Cardiovascular Agents/adverse effects , Coronary Angiography , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Restenosis/etiology , Paclitaxel/administration & dosage , Paclitaxel/adverse effects , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Randomized Controlled Trials as Topic , Risk Factors , Time Factors , Treatment Outcome
6.
EuroIntervention ; 20(13): e818-e825, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38949242

ABSTRACT

BACKGROUND: There are limited data about determinant factors of target lesion failure (TLF) in lesions after percutaneous coronary intervention (PCI) using a drug-coated balloon (DCB) for de novo coronary artery lesions, including optical coherence tomography (OCT) findings. AIMS: The present study aims to investigate the associated factors of TLF in de novo coronary artery lesions with DCB treatment. METHODS: We retrospectively enrolled 328 de novo coronary artery lesions in 328 patients who had undergone PCI with a DCB. All lesions had been treated without a stent, and both pre- and post-PCI OCT had been carried out. Patients were divided into two groups, with or without TLF, which was defined as a composite of culprit lesion-related cardiac death, myocardial infarction, and target lesion revascularisation, and the associated factors of TLF were assessed. RESULTS: At the median follow-up period of 460 days, TLF events occurred in 31 patients (9.5%) and were associated with patients requiring haemodialysis (HD; 29.0% vs 10.8%), with a severely calcified lesion (median maximum calcium arc 215° vs 104°), and with the absence of OCT medial dissection (16.1% vs 60.9%) as opposed to those without TLF events. In Cox multivariable logistic regression analysis, HD (hazard ratio [HR]: 2.26, 95% confidence interval [CI]: 1.00-5.11; p=0.049), maximum calcium arc (per 90°, HR: 1.34, 95% CI: 1.05-1.72; p=0.02), and the absence of post-PCI medial dissection on OCT (HR: 8.24, 95% CI: 3.15-21.6; p<0.001) were independently associated with TLF. CONCLUSIONS: In de novo coronary artery lesions that received DCB treatment, factors associated with TLF were being on HD, the presence of a severely calcified lesion, and the absence of post-PCI medial dissection.


Subject(s)
Coronary Artery Disease , Percutaneous Coronary Intervention , Tomography, Optical Coherence , Humans , Male , Female , Aged , Middle Aged , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Retrospective Studies , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/methods , Risk Factors , Treatment Outcome , Coronary Vessels/diagnostic imaging , Drug-Eluting Stents , Myocardial Infarction/etiology
7.
BMC Cardiovasc Disord ; 24(1): 311, 2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38898393

ABSTRACT

BACKGROUND: Calcified lesions are one of the most challenging cases for PCI, where optimal angiographic results and satisfying outcomes are hard to achieve. METHODS: We evaluated the baseline clinical, procedures characteristics and outcomes of patients with severe coronary artery calcification (CAC) who underwent coronary intravascular lithotripsy (IVL) and rotational atherectomy (RA). RESULTS: Respectively 152 and 238 patients who underwent IVL and RA are enrolled from January 2023 to November 2023. Regarding demographic characteristics, the gender proportion, medical history of PCI and smoke history among groups reach statistical significance. Left anterior descending and right coronary artery were the main vessels treated in both groups. The 2.5 and 3.0 mm IVL balloons and 1.5 mm burr were the most commonly used. 99.3% cases were successfully implanted drug-eluting stents after IVL balloon pre-treatment, which was higher than in the group treated with RA. During hospitalization, there were no serious adverse events in the IVL group, but there were two adverse events in the RA group. Procedural complications were higher in the RA group than the IVL group (5.5% vs. 0.7%, P = 0.027). CONCLUSIONS: IVL appears to be safe and effective for the treatment of severe CAC lesions compared to RA.


Subject(s)
Atherectomy, Coronary , Coronary Artery Disease , Lithotripsy , Severity of Illness Index , Vascular Calcification , Humans , Atherectomy, Coronary/adverse effects , Male , Female , Vascular Calcification/therapy , Vascular Calcification/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Aged , Treatment Outcome , Middle Aged , Retrospective Studies , Risk Factors , Time Factors , Drug-Eluting Stents , Coronary Angiography , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/adverse effects , Aged, 80 and over
8.
BMC Cardiovasc Disord ; 24(1): 324, 2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38918738

ABSTRACT

BACKGROUND: With advancements in chronic total coronary occlusion (CTO) recanalization techniques and concepts, the success rate of recanalization has been steadily increasing. However, the current data are too limited to draw any reliable conclusions about the efficacy and safety of drug-coated balloons (DCBs) in CTO percutaneous coronary intervention (PCI). Herein, we conducted a meta-analysis to confirm the efficacy of DCB in CTO PCI. METHODS: We systematically searched PubMed, Web of Science and Embase from inception to July 25, 2023. The primary outcome was major advent cardiovascular events (MACE), including cardiac death, nonfatal myocardial infarction (MI), target lesion revascularization (TLR), and target vessel revascularization (TVR). The follow-up angiographic endpoints were late lumen enlargement (LLE), reocclusion and restenosis. RESULTS: Five studies with a total of 511 patients were included in the meta-analysis. Across studies, patients were predominantly male (72.9-85.7%) and over fifty years old. The summary estimate rate of MACE was 13.0% (95% CI 10.1%-15.9%, I2 = 0%, p = 0.428). The summary estimate rates of cardiac death and MI were 2.2% (95% CI 0.7%-3.7%, I2 = 0%, p = 0.873) and 1.2% (95% CI -0.2-2.6%, I2 = 13.7%, p = 0.314), respectively. Finally, the pooled incidences of TLR and TVR were 10.1% (95% CI 5.7%-14.5%, I2 = 51.7%, p = 0.082) and 7.1% (95% CI 3.0%-11.2%, I2 = 57.6%, p = 0.070), respectively. Finally, the summary estimate rates of LLE, reocclusion and restenosis were 59.4% (95% CI 53.5-65.3%, I2 = 0%, p = 0.742), 3.3% (95% CI 1.1-5.4%, I2 = 0%, p = 0.865) and 17.5% (95% CI 12.9-22.0%, I2 = 0%, p = 0.623), respectively. CONCLUSION: Accordingly, DCB has the potential to be used as a treatment for CTO in suitable patients.


Subject(s)
Angioplasty, Balloon, Coronary , Cardiac Catheters , Coated Materials, Biocompatible , Coronary Occlusion , Humans , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/mortality , Coronary Occlusion/therapy , Treatment Outcome , Chronic Disease , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/mortality , Risk Factors , Aged , Female , Middle Aged , Male , Cardiovascular Agents/administration & dosage , Cardiovascular Agents/adverse effects , Aged, 80 and over , Risk Assessment , Time Factors , Equipment Design , Coronary Restenosis/etiology , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/mortality
9.
Int J Cardiol ; 412: 132269, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-38880417

ABSTRACT

INTRODUCTION: In-stent restenosis (ISR) is seen in up to 20% of cases and is the primary cause of percutaneous coronary intervention (PCI) failure. With the use of re-stenting with a drug-eluting stent (DES), plain old balloon angioplasty (BA) use is decreasing. We aim to compare the efficacy and safety profile of DES over BA in the management of ISR. METHODS: Electronic databases were searched to identify all randomized controlled trials (RCTs) comparing DES to BA for coronary ISR. The mantel-Haenszel method with a random effects model was used to calculate pooled risk ratios (RR). RESULTS: Four trials comprising 912 patients (543 in DES and 369 in the BA group) were included in the final study. The mean follow-up was 45 months. DES was found to be superior with a lower requirement of target vessel revascularization (TVR) (RR: 0.45, 95% CI: 0.31-0.64, p-value <0.0001), and target lesion revascularization (TLR) (RR: 0.59, 95%CI: 0.44-0.78, p-value 0.0002) compared to BA. However, all-cause mortality, cardiovascular mortality, incidence of myocardial infarction (MI), and target lesion thrombosis were not different between the two intervention arms. CONCLUSION: DES was found to be superior to BA for the management of coronary ISR with a reduction in the risk of TLR and TVR. No difference in mortality, risk of MI, or target lesion thrombosis was observed between the two interventions.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Restenosis , Drug-Eluting Stents , Randomized Controlled Trials as Topic , Humans , Angioplasty, Balloon, Coronary/methods , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/instrumentation , Coronary Restenosis/epidemiology , Coronary Restenosis/etiology , Drug-Eluting Stents/adverse effects , Percutaneous Coronary Intervention/methods , Percutaneous Coronary Intervention/adverse effects , Randomized Controlled Trials as Topic/methods , Treatment Outcome
14.
JACC Cardiovasc Interv ; 17(13): 1519-1528, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38842991

ABSTRACT

BACKGROUND: Drug-coated balloon (DCB) angioplasty seems a safe and effective option for specific de novo coronary lesions. However, the beneficial effect of intravascular ultrasound (IVUS)-guided DCB angioplasty in de novo lesions remains uncertain. OBJECTIVES: This study aimed to assess the benefits of IVUS guidance over angiography guidance during DCB angioplasty in de novo coronary lesions. METHODS: A total of 260 patients with high bleeding risk who had a de novo coronary lesion (reference vessel diameter 2.0-4.0 mm, and lesion length ≤15 mm) were randomly assigned to either an IVUS-guided or an angioplasty-guided DCB angioplasty group. The primary endpoint was in-segment late lumen loss (LLL) at 7 months after procedure. The secondary endpoint was target vessel failure at 6 months. RESULTS: A total of 2 patients in the angiography-guided group and 7 patients in the IVUS-guided group underwent bailout stent implantation (P = 0.172). The primary endpoint of 7-month LLL was 0.03 ± 0.52 mm with angiography guidance vs -0.10 ± 0.34 mm with IVUS guidance (mean difference 0.14 mm; 95% CI: 0.02-0.26; P = 0.025). IVUS guidance was also associated with a larger 7-month minimal lumen diameter (2.06 ± 0.62 mm vs 1.75 ± 0.63 mm; P < 0.001) and a smaller diameter stenosis (28.15% ± 13.88% vs 35.83% ± 17.69%; P = 0.001) compared with angiography guidance. Five target vessel failures occurred at 6 months, with 4 (3.1%) in the angiography-guided group and 1 (0.8%) in the IVUS-guided group (P = 0.370). CONCLUSIONS: This study demonstrated that IVUS-guided DCB angioplasty is associated with a lower LLL in patients with a de novo coronary lesion compared with angiography guidance. (Intravascular Ultrasound Versus Angiography Guided Drug-Coated Balloon [ULTIMATE-III]; NCT04255043).


Subject(s)
Angioplasty, Balloon, Coronary , Cardiac Catheters , Cardiovascular Agents , Coated Materials, Biocompatible , Coronary Angiography , Coronary Artery Disease , Predictive Value of Tests , Ultrasonography, Interventional , Humans , Male , Female , Middle Aged , Aged , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/adverse effects , Treatment Outcome , Time Factors , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Cardiovascular Agents/administration & dosage , Cardiovascular Agents/adverse effects , Prospective Studies , Risk Factors , China
15.
Curr Cardiol Rep ; 26(7): 681-688, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38850397

ABSTRACT

PURPOSE OF REVIEW: This review aims to explain the current advancements in the treatment modalities for small vessel coronary artery disease (SVCAD) and de novo lesions post-percutaneous coronary intervention (PCI), focusing on drug-coated stents (DES) and drug-coated balloons (DCB). Its goal is to address the lack of standards in the management of these lesions and to assess the potential of DCB as a preferential treatment strategy over DES in the long term. RECENT FINDINGS: Technological advancements have improved drug-eluting stents (DES) and drug-coated balloons (DCB) which offer a more promising avenue for managing SVCAD. According to new data, DCBs, initially recognized for their efficacy in preventing restenosis within three to five years of stent placement, may offer superior outcomes compared to DES in certain clinical scenarios. This review shows that DCBs have a favorable therapeutic profile in the treatment of SVCAD, and they could be considered as an alternative to DES. Although the initial data is compelling, definitive conclusions cannot be met without further large-scale, long-term clinical trials. The implication of these findings suggests a shift in the future of SVCAD management and requires additional research to substantiate the long-term benefits of DCB use in SVCAD. Should ongoing and future studies corroborate the current evidence, DCB could emerge as the standard of care for SVCAD, significantly influencing clinical practices and future research.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/methods , Coated Materials, Biocompatible , Coronary Artery Disease/therapy , Coronary Restenosis/prevention & control , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Treatment Outcome
16.
BMC Cardiovasc Disord ; 24(1): 319, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38914951

ABSTRACT

BACKGROUND: Percutaneous coronary intervention (PCI) with primary stenting, which stands for stent implantation regardless of obtaining satisfactory results with balloon angioplasty, has superseded conventional plain old balloon angioplasty with provisional stenting. With drug-coated balloon (DCB), primary DCB angioplasty with provisional stenting has shown non-inferiority to primary stenting for de novo coronary small vessel disease. However, the long-term efficacy and safety of such a strategy to the primary stenting on clinical endpoints in de novo lesions without vessel diameter restrictions remain uncertain. STUDY DESIGN: The REC-CAGEFREE I is an investigator-initiated, multicenter, randomized, open-label trial aimed to enroll 2270 patients with acute or chronic coronary syndrome from 43 interventional cardiology centers in China to evaluate the non-inferiority of primary paclitaxel-coated balloons angioplasty to primary stenting for the treatment of de novo, non-complex lesions without vessel diameter restrictions. Patients who fulfill all the inclusion and exclusion criteria and have achieved a successful lesion pre-dilatation will be randomly assigned to the two arms in a 1:1 ratio. Protocol-guided DCB angioplasty and bailout stenting after unsatisfactory angioplasty are mandatory in the primary DCB angioplasty group. The second-generation sirolimus-eluting stent will be used as a bailout stent in the primary DCB angioplasty group and the treatment device in the primary stenting group. The primary endpoint is the incidence of Device-oriented Composite Endpoint (DoCE) within 24 months after randomization, including cardiac death, target vessel myocardial infarction, and clinically and physiologically indicated target lesion revascularization. DISCUSSION: The ongoing REC-CAGEFREE I trial is the first randomized trial with a clinical endpoint to assess the efficacy and safety of primary DCB angioplasty for the treatment of de novo, non-complex lesions without vessel diameter restrictions. If non-inferiority is shown, PCI with primary DCB angioplasty could be an alternative treatment option to primary stenting. TRIAL REGISTRATION: Registered on clinicaltrial.gov (NCT04561739).


Subject(s)
Angioplasty, Balloon, Coronary , Cardiac Catheters , Cardiovascular Agents , Coated Materials, Biocompatible , Coronary Artery Disease , Paclitaxel , Humans , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/mortality , Treatment Outcome , Cardiovascular Agents/administration & dosage , Cardiovascular Agents/adverse effects , China , Paclitaxel/administration & dosage , Paclitaxel/adverse effects , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Time Factors , Female , Male , Middle Aged , Multicenter Studies as Topic , Stents , Aged , Drug-Eluting Stents , Equivalence Trials as Topic , Randomized Controlled Trials as Topic
17.
Lasers Surg Med ; 56(5): 474-484, 2024 07.
Article in English | MEDLINE | ID: mdl-38738401

ABSTRACT

OBJECTIVES: The aim of this study is to investigate the safety and efficacy of excimer laser coronary angioplasty (ELCA) combined with drug-coated balloons (DCBs) in the treatment of in-stent restenosis (ISR), and to explore whether the contrast injection technique would improve the neointimal tissue ablation of ELCA. METHODS: We studied patients diagnosed with ISR between January 2019 and October 2022 at two medical centers. These patients underwent DCB angioplasty guided by optical coherence tomography (OCT). Based on whether ELCA was performed before DCB treatment, patients were categorized into two groups: the ELCA + DCB group and the DCB group. All patients underwent clinical follow-up 1 year after the procedure. The primary endpoint was the 1-year rate of target lesion revascularization (TLR), which was defined as any repeat percutaneous intervention or bypass surgery on the target vessel conducted to address restenosis or other complications related to the target lesion. The secondary endpoints including immediate luminal gain (ΔMLA, defined as the difference in minimum lumen area before and after the intervention). RESULTS: A total of 85 lesions in 75 patients were included. The mean age of the study population was 64.2 ± 12.0 years, with 81.3% male. Baseline clinical characteristics were well-balanced, and procedural success was 100% in both groups. The ELCA + DCB group (n = 24) exhibited a greater ΔMLA compared to the DCB group (n = 61) (3.57 ± 0.79 mm² vs. 2.50 ± 1.06 mm², [95% confidence interval, CI: 0.57-1.69], p < 0.001), The reduction in 1-year TLR was more frequently observed in patients from the ELCA + DCB group compared to the DCB group (hazard ratio 0.33 [95% CI: 0.11-0.99]; log-rank p = 0.048). The exploratory analysis showed that ELCA with contrast infusion is associated with greater acute lumen gain compared to ELCA with saline infusion (p < 0.001). CONCLUSIONS: The combination of ELCA and DCB is a safe and effective treatment strategy for in-stent stenosis. Additionally, compared with saline injection, ELCA with contrast injection is associated with greater acute lumen gain. However, the optimal contrast agent concentration and long-term outcome of the contrast injection technique need confirmation through larger sample sizes and prospective studies.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Restenosis , Lasers, Excimer , Humans , Male , Middle Aged , Female , Coronary Restenosis/therapy , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Aged , Lasers, Excimer/therapeutic use , Angioplasty, Balloon, Coronary/instrumentation , Treatment Outcome , Retrospective Studies , Drug-Eluting Stents , Tomography, Optical Coherence , Combined Modality Therapy , Angioplasty, Balloon, Laser-Assisted
18.
EuroIntervention ; 20(9): 602-612, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726721

ABSTRACT

BACKGROUND: Late lumen enlargement (LLE) - a positive remodelling phenomenon - after drug-coated balloon (DCB) angioplasty for stable coronary disease contributes to a lower restenosis rate. However, lesion characteristics promoting LLE remain unclear. AIMS: This study aimed to investigate predictive lesion characteristics for LLE using serial optical frequency domain imaging (OFDI) following DCB angioplasty for de novo coronary artery lesions. METHODS: This retrospective, single-centre observational study included patients with angina pectoris who underwent paclitaxel-coated balloon angioplasty without stenting under OFDI guidance as well as follow-up OFDI. OFDI endpoints were lumen volume, plaque phenotype, and procedure-associated dissection. LLE was defined as a ≥10% increase in the lumen volume of the treated lesion at follow-up. RESULTS: Between August 2016 and December 2019, among patients with successful DCB angioplasty, 108 lesions (83 patients) had available follow-up imaging after a median of 6.1 months. LLE was detected in 44 (40.7%) lesions. Fibrous/fibrocalcific and layered plaques had significantly larger lumen volumes at follow-up than immediately after the index procedure, whereas lipid plaques exhibited no significant difference. Medial dissection with an arc >90° revealed an increased lumen volume. Multivariate analysis showed that layered plaques (odds ratio [OR] 8.73, 95% confidence interval [CI]: 1.92-39.7; p=0.005) and medial dissection with an arc >90° (OR 4.65, 95% CI: 1.63-13.3; p=0.004) were independent LLE predictors. CONCLUSIONS: Layered plaques and extensive medial dissection after DCB angioplasty were associated with higher LLE occurrence in de novo coronary lesions. These findings may be clinically applicable to DCB therapeutic strategies based on plaque features.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Artery Disease , Paclitaxel , Humans , Male , Female , Aged , Middle Aged , Retrospective Studies , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/methods , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Paclitaxel/therapeutic use , Paclitaxel/administration & dosage , Coronary Vessels/diagnostic imaging , Treatment Outcome , Coated Materials, Biocompatible , Plaque, Atherosclerotic , Tomography, Optical Coherence , Coronary Angiography
19.
Catheter Cardiovasc Interv ; 104(1): 23-26, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38764302

ABSTRACT

We report two case series in which we encountered the difficulties to retrieve disrupted devices during percutaneous coronary intervention and endovascular treatment. The broken devices were successfully and safely retrieved by the "flower technique" that creates multiple cut and slit in the tip of the guiding catheter. This technique can be easily and safely applied in situations where a balloon catheter or stent has been disrupted and device entrapment has occurred, as the technique simply involves manually placing multiple cuts or slits in the tip of the guiding catheter. Transcatheter interventionists should be familiar with this technique because it can be bailout from device entrapment without additional cost or clinical experience.


Subject(s)
Angioplasty, Balloon, Coronary , Cardiac Catheters , Device Removal , Humans , Male , Treatment Outcome , Angioplasty, Balloon, Coronary/instrumentation , Stents , Aged , Equipment Failure , Middle Aged , Female , Equipment Design
SELECTION OF CITATIONS
SEARCH DETAIL