Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 4.382
Filter
1.
JACC Cardiovasc Interv ; 17(15): 1795-1807, 2024 Aug 12.
Article in English | MEDLINE | ID: mdl-39142756

ABSTRACT

BACKGROUND: The Valve Academic Research Consortium (VARC)-3 definition for neurologic events after transcatheter aortic valve replacement (TAVR) lacks clinical validation. OBJECTIVES: This study sought to determine the incidence, predictors, and clinical impact of neurologic events following TAVR as defined by VARC-3 criteria. METHODS: This was a multicenter study including 2,924 patients with severe aortic stenosis undergoing TAVR. Based on Neurologic Academic Research Consortium (NeuroARC) classification, neurologic events were classified as NeuroARC type 1 (stroke), NeuroARC type 2 (covert central nervous system injury), and NeuroARC type 3 (transient ischemic attack and delirium). Baseline, procedural, and follow-up data were prospectively collected in a dedicated database. RESULTS: After a median follow-up of 13 (7-37) months, neurologic events occurred in 471 patients (16.1%), NeuroARC type 1, 2, and 3 in 37.4%, 4.7%, and 58.0% of cases, respectively, and the majority (58.6%) were periprocedural. Advanced age, chronic kidney disease, atrial fibrillation, major vascular complications, and in-hospital bleeding determined an increased risk of periprocedural events (P < 0.03 for all). Neurologic events occurring during the periprocedural time frame were independently associated with a substantial increase in mortality at 1 year after the intervention (HR: 1.91; 95% CI: 1.23-2.97; P = 0.004). However, although NeuroARC type 1 was associated with an increased mortality risk (IRR: 3.38; 95% CI: 2.30-5.56; P < 0.001 and IRR: 21.7; 95% CI: 9.63-49.1; P < 0.001 for ischemic and hemorrhagic stroke, respectively), the occurrence of NeuroARC type 3 events had no impact on mortality. CONCLUSIONS: Neurologic events after TAVR were associated with poorer short- and long-term survival. This correlation was related to the type of NeuroARC event defined by the VARC-3 criteria. Given the negative impact on clinical outcomes, every attempt should be made to reduce the risk of neurologic complications after TAVR.


Subject(s)
Aortic Valve Stenosis , Ischemic Attack, Transient , Severity of Illness Index , Stroke , Transcatheter Aortic Valve Replacement , Humans , Male , Risk Factors , Female , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Incidence , Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Aged, 80 and over , Time Factors , Risk Assessment , Ischemic Attack, Transient/etiology , Ischemic Attack, Transient/mortality , Ischemic Attack, Transient/epidemiology , Treatment Outcome , Stroke/mortality , Stroke/etiology , Stroke/epidemiology , Delirium/epidemiology , Delirium/etiology , Delirium/diagnosis , Delirium/mortality , Databases, Factual , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging
4.
Circ Cardiovasc Imaging ; 17(8): e016489, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39163368

ABSTRACT

BACKGROUND: Left ventricular (LV) hypertrophy occurs in both aortic stenosis (AS) and systemic hypertension (HTN) in response to wall stress. However, differentiation of hypertrophy due to these 2 etiologies is lacking. The aim was to study the 3-dimensional geometric remodeling pattern in severe AS pre- and postsurgical aortic valve replacement and to compare with HTN and healthy controls. METHODS: Ninety-one subjects (36 severe AS, 19 HTN, and 36 healthy controls) underwent cine cardiac magnetic resonance. Cardiac magnetic resonance was repeated 8 months post-aortic valve replacement (n=18). Principal component analysis was performed on the 3-dimensional meshes reconstructed from 109 cardiac magnetic resonance scans of 91 subjects at end-diastole. Principal component analysis modes were compared across experimental groups together with conventional metrics of shape, strain, and scar. RESULTS: A unique AS signature was identified by wall thickness linked to a LV left-right axis shift and a decrease in short-axis eccentricity. HTN was uniquely linked to increased septal thickness. Combining these 3 features had good discriminative ability between AS and HTN (area under the curve, 0.792). The LV left-right axis shift was not reversible post-aortic valve replacement, did not associate with strain, age, or sex, and was predictive of postoperative LV mass regression (R2=0.339, P=0.014). CONCLUSIONS: Unique remodeling signatures might differentiate the etiology of LV hypertrophy. Preliminary findings suggest that LV axis shift is characteristic in AS, is not reversible post-aortic valve replacement, predicts mass regression, and may be interpreted to be an adaptive mechanism.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Hypertension , Hypertrophy, Left Ventricular , Magnetic Resonance Imaging, Cine , Ventricular Function, Left , Ventricular Remodeling , Humans , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnostic imaging , Female , Male , Magnetic Resonance Imaging, Cine/methods , Middle Aged , Hypertension/physiopathology , Hypertension/complications , Aged , Hypertrophy, Left Ventricular/physiopathology , Hypertrophy, Left Ventricular/etiology , Hypertrophy, Left Ventricular/diagnostic imaging , Ventricular Function, Left/physiology , Case-Control Studies , Predictive Value of Tests , Treatment Outcome , Diagnosis, Differential , Principal Component Analysis , Severity of Illness Index , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/pathology , Time Factors , Imaging, Three-Dimensional
5.
Article in English | MEDLINE | ID: mdl-39198196

ABSTRACT

PURPOSE: Aortic valve neocuspidization (AVNeo) is a relatively recent advancement in surgical AV replacement. Data on its performance beyond the short term are limited. We assessed the mid-term outcomes in patients undergoing AVNeo, focusing on feasibility, perioperative details, and its role in AV pathology treatment. METHODS: Sixty-five consecutive patients underwent AVNeo between December 2016 and February 2018. Clinical data were prospectively collected and retrospectively analyzed. Tricuspid reconstruction with autologous pericardium was performed in all cases. Echocardiographic follow-up was conducted post-discharge, at 6 and 12 months, and annually thereafter. RESULTS: The mean age was 62.6 ± 18.7 years. AVNeo was feasible in all cases. Concomitant procedures were performed in 43 (66.2%) patients. Mean bypass and cross-clamp times were 119.2 ± 30.3 and 87.1 ± 22.9 minutes, respectively. Postoperative transvalvular hemodynamics was excellent. There was one (1.5%) in-hospital death. Follow-up (mean 66.72 ± 12.77 months) was complete in 58 patients (89.2%). There were no detected valve-related or thromboembolic events. Transvalvular hemodynamic parameters were stable during the observation period: peak pressure gradient at discharge and follow-up was 15.3 ± 4.6 mmHg and 15.01 ± 6.3 mmHg, respectively (ρ = 0.346). CONCLUSIONS: AVNeo demonstrated the feasibility and favorable mid-term outcomes. Studies with longer-term observation are warranted to evaluate its durability.


Subject(s)
Aortic Valve , Feasibility Studies , Heart Valve Prosthesis Implantation , Pericardium , Transplantation, Autologous , Humans , Middle Aged , Male , Female , Pericardium/transplantation , Aged , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Treatment Outcome , Retrospective Studies , Time Factors , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Adult , Hemodynamics , Recovery of Function , Postoperative Complications/etiology , Risk Factors , Plastic Surgery Procedures/adverse effects , Plastic Surgery Procedures/methods , Aged, 80 and over
6.
JACC Cardiovasc Interv ; 17(16): 1905-1915, 2024 Aug 26.
Article in English | MEDLINE | ID: mdl-39197989

ABSTRACT

BACKGROUND: Tricuspid regurgitation (TR) is associated with worse clinical outcomes after transcatheter aortic valve replacement (TAVR) and mitral transcatheter edge-to-edge repair (M-TEER), but little is known about its association with health status outcomes. OBJECTIVES: The aims of this study were to explore, using the Society of Thoracic Surgeons and American College of Cardiology TVT (Transcatheter Valve Therapy) Registry, the association between baseline TR and health status after TAVR and M-TEER and to determine if baseline TR was associated with clinical endpoints. METHODS: Health status was assessed using Kansas City Cardiomyopathy Questionnaire overall summary (KCCQ-OS) score in patients enrolled in the TVT Registry who underwent isolated TAVR or M-TEER between January 2019 and June 2021. The association among baseline TR and KCCQ-OS score, being alive and well, and clinical outcomes was examined. RESULTS: In total, 130,097 TAVR patients (13.1% with moderate TR, 2.3% with severe TR) and 19,593 M-TEER patients (33.2% with moderate TR, 14.7% with severe TR) were included. Mean KCCQ-OS scores were lower with severe vs moderate vs none to mild TR at baseline prior to TAVR (39.4 ± 24.2 vs 45.2 ± 24.7 vs 51.3 ± 25.3; P < 0.01) or M-TEER (38.1 ± 23.9 vs 41.9 ± 24.7 vs 45.4 ± 25.2; P < 0.01) and similarly at 30 days and 1 year. The odds of being alive and well at 1 year were lower with moderate or severe TR before TAVR (adjusted OR: 0.79 [95% CI: 0.74-0.85] and adjusted OR: 0.81 [95% CI: 0.70-0.94], respectively) and severe TR before M-TEER (adjusted OR: 0.53; 95% CI: 0.40-0.71). Furthermore, moderate or severe TR before TAVR was associated with higher 1-year mortality and readmission, whereas moderate or severe TR before M-TEER was associated with higher 1-year mortality. CONCLUSIONS: In a large cohort of U.S. patients who underwent TAVR or M-TEER, greater baseline TR was associated with worse health status and clinical outcomes. Understanding adverse outcomes of TR in patients with coexisting valvular abnormalities is important, especially with rapidly evolving transcatheter tricuspid valve interventions.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Health Status , Mitral Valve , Registries , Transcatheter Aortic Valve Replacement , Tricuspid Valve Insufficiency , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Female , Male , Treatment Outcome , Tricuspid Valve Insufficiency/physiopathology , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/mortality , Tricuspid Valve Insufficiency/surgery , Aged , Time Factors , Aged, 80 and over , Risk Factors , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Mitral Valve/surgery , Mitral Valve/physiopathology , Mitral Valve/diagnostic imaging , United States , Risk Assessment , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/mortality , Severity of Illness Index , Recovery of Function , Tricuspid Valve/physiopathology , Tricuspid Valve/surgery , Tricuspid Valve/diagnostic imaging , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Cardiac Catheterization/mortality
7.
JACC Cardiovasc Interv ; 17(16): 1916-1931, 2024 Aug 26.
Article in English | MEDLINE | ID: mdl-39197990

ABSTRACT

BACKGROUND: Tricuspid regurgitation (TR) is highly prevalent in the transcatheter aortic valve replacement (TAVR) population, but clear management guidelines are lacking. OBJECTIVES: The aims of this study were to elucidate the prevalence and consequences of severe TR in patients with aortic stenosis undergoing TAVR and to examine the change in TR post-TAVR, including predictors of improvement and its impact on longer term mortality. METHODS: Using Centers for Medicare and Medicaid Services-linked TVT (Transcatheter Valve Therapy) Registry data, a propensity-matched analysis was performed among patients undergoing TAVR with baseline mild, moderate, or severe TR. Kaplan-Meier estimates were used to assess the impact of TR on 3-year mortality. Multivariable analysis identified predictors of 30-day TR improvement. RESULTS: Of the 312,320 included patients, 84% had mild, 13% moderate, and 3% severe TR. In a propensity-matched cohort, severe baseline TR was associated with higher in-hospital mortality (2.5% vs 2.1% for moderate TR and 1.8% for mild TR; P = 0.009), higher 1-year mortality (24% vs 19.6% for moderate TR and 16.6% for mild TR; P < 0.0001), and 3-year mortality (54.2% vs 48.5% for moderate TR and 43.3% for mild TR; P < 0.0001). Among the patients with severe TR at baseline, 76.4% improved to moderate or less TR 30 days after TAVR. Baseline mitral regurgitation moderate or greater, preserved ejection fraction, higher aortic valve gradient, and better kidney function predicted TR improvement after TAVR. However, severe 30-day residual TR was associated with higher 1-year mortality (27.4% vs 18.7% for moderate TR and 16.8% for mild TR; P < 0.0001). CONCLUSIONS: Severe baseline and 30-day residual TR after TAVR are associated with increased mortality up to 3 years. This analysis identifies a higher risk group that could be evaluated for the recently approved tricuspid interventions.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Balloon Valvuloplasty , Heart Valve Prosthesis , Hospital Mortality , Prosthesis Design , Recovery of Function , Registries , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Tricuspid Valve Insufficiency , Humans , Male , Female , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Aged, 80 and over , Treatment Outcome , Tricuspid Valve Insufficiency/physiopathology , Tricuspid Valve Insufficiency/mortality , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery , Aged , United States/epidemiology , Risk Factors , Time Factors , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Balloon Valvuloplasty/mortality , Balloon Valvuloplasty/adverse effects , Risk Assessment , Prevalence , Tricuspid Valve/physiopathology , Tricuspid Valve/surgery , Tricuspid Valve/diagnostic imaging , Retrospective Studies , Centers for Medicare and Medicaid Services, U.S. , Hemodynamics
8.
BMC Cardiovasc Disord ; 24(1): 448, 2024 Aug 24.
Article in English | MEDLINE | ID: mdl-39182065

ABSTRACT

OBJECTIVE: This study aimed to identify the incidence, risk factors, and outcomes of permanent pacemaker (PPM) implantation after transcatheter aortic valve implantation (TAVI) procedures. METHODS: A retrospective analysis was conducted on 70 patients who underwent TAVI at the Department of Cardiology, Fujian Provincial Hospital, from January 2018 to March 2022. Based on whether a new PPM was implanted after TAVI, all patients were divided into two groups: NEW PPM and NO PPM. Baseline characteristics and clinical data were compared between the two groups. Univariate analysis was used to analyze different variables between the two groups. A binary logistic regression analysis was used to evaluate independent correlates for PPM implantation after TAVI. RESULTS: The mean age of the 70 patients was 73.1 ± 8.8 years. The incidence of PPM implantation was 17.1%. Patients with diabetes and chronic kidney disease were more likely to require PPM (50% vs. 20.7%, p = 0.042, 25% vs. 5.2%, p = 0.042). Our study did not identify any significant differences in the incidence of electrocardiographic conduction disturbances except for the previous right bundle branch block (RBBB) (NO PPM 6.9% vs. NEW PPM 33.3%, p < 0.05). We found that prosthesis size, implantation depth, procedural duration, and length of hospital and intensive care unit (ICU) stays were comparable between the two groups. The leading independent predictors of PPM implantation were previous RBBB (odds ratio 10.129, p = 0.034). CONCLUSION: The previous RBBB was the leading independent predictor of PPM implantation. New PPM was not associated with significantly new-onset left BBB, extended post-procedure hospitalization, ICU stay, or procedural duration.


Subject(s)
Aortic Valve Stenosis , Cardiac Pacing, Artificial , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Transcatheter Aortic Valve Replacement/adverse effects , Retrospective Studies , Risk Factors , Aged , Treatment Outcome , Cardiac Pacing, Artificial/adverse effects , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aged, 80 and over , Time Factors , Risk Assessment , China/epidemiology , Incidence , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/epidemiology
9.
Comput Methods Programs Biomed ; 255: 108369, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39146759

ABSTRACT

BACKGROUND AND OBJECTIVE: The evidence on the role of hemodynamics in aorta pathophysiology has yet to be robustly translated into clinical applications, to improve risk stratification of aortic diseases. Motivated by the need to enrich the current understanding of the pathophysiology of the ascending aorta (AAo), this study evaluates in vivo how large-scale aortic flow coherence is affected by AAo dilation and aortic valve phenotype. METHODS: A complex networks-based approach is applied to 4D flow MRI data to quantify subject-specific AAo flow coherence in terms of correlation between axial velocity waveforms and the aortic flow rate waveform along the cardiac cycle. The anatomical length of persistence of such correlation is quantified using the recently proposed network metric average weighted curvilinear distance (AWCD). The analysis considers 107 subjects selected to allow an ample stratification in terms of aortic valve morphology, absence/presence of AAo dilation and of aortic valve stenosis. RESULTS: The analysis highlights that the presence of AAo dilation as well as of bicuspid aortic valve phenotype breaks the physiological AAo flow coherence, quantified in terms of AWCD. Of notice, it emerges that cycle-average blood flow rate and relative AAo dilation are main determinants of AWCD, playing opposite roles in promoting and hampering the persistence of large-scale flow coherence in AAo, respectively. CONCLUSIONS: The findings of this study can contribute to broaden the current mechanistic link between large-scale blood flow coherence and aortic pathophysiology, with the prospect of enriching the existing tools for the in vivo non-invasive hemodynamic risk assessment for aortic diseases onset and progression.


Subject(s)
Aorta , Aortic Valve , Magnetic Resonance Imaging , Phenotype , Humans , Aorta/diagnostic imaging , Aorta/physiopathology , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Magnetic Resonance Imaging/methods , Male , Female , Middle Aged , Adult , Hemodynamics , Blood Flow Velocity , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aged , Bicuspid Aortic Valve Disease/physiopathology , Bicuspid Aortic Valve Disease/diagnostic imaging
10.
J Am Heart Assoc ; 13(14): e033125, 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-38979804

ABSTRACT

BACKGROUND: Mitral regurgitation (MR) is frequent in patients with aortic stenosis (AS). Although primary MR is an established negative prognostic factor, whether different mechanisms of MR have different effects on outcome is currently unknown. The aim of this study was to evaluate the impact of the MR mechanism in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: This is a retrospective observational study of patients who underwent TAVR for severe aortic stenosis in a high-volume tertiary care center. Echocardiographic comprehensive MR assessment was performed at baseline and within 3 months post TAVR. The study population was divided into 4 groups according to MR mechanism: Group I: fibro-calcific leaflet degeneration; Group II: prolapse/flail; Group III: ventricular secondary MR (functional MR); and Group IV: atrial functional MR. The study end point was a combination of death from cardiovascular cause and heart failure-related hospitalization. The study population included 427 patients (mean age 81.7±6.5 years; 71% primary MR; 62% ≥moderate MR). At 3-year follow-up, survival free from the composite end point significantly differs according to MR mechanism: it was higher in group IV (atrial functional MR, 96.6%) compared with group I (80.4%, P=0.002) and group II patients (60.7%, P=0.001), and group III (84.8%, P=0.037); patients with MR due to leaflet prolapse showed poorer prognosis compared with patients with functional MR (group III, P=0.023 and group IV, P=0.001) and with group I (P=0.040). Overall, severe MR after TAVR identified patients with poorer prognosis and was significantly more frequent in group II (46.4%, P=0.001). CONCLUSIONS: In patients undergoing TAVR, preprocedural identification of MR mechanism and mechanism provides prognostic insights.


Subject(s)
Aortic Valve Stenosis , Mitral Valve Insufficiency , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Male , Female , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/diagnostic imaging , Retrospective Studies , Aged, 80 and over , Aged , Treatment Outcome , Echocardiography , Risk Factors , Time Factors , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology
11.
JACC Cardiovasc Interv ; 17(14): 1631-1651, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39048251

ABSTRACT

Transcatheter aortic valve replacement (TAVR) has become more common than surgical aortic valve replacement since 2016, with over 200,000 procedures globally each year. As patients increasingly outlive their TAVR devices, managing these cases is a growing concern. Treatment options include surgical removal of the old TAVR device (transcatheter aortic valve [TAV] explant) or implantation of a new transcatheter aortic valve (redo TAV). Redo TAV is complex because of the unique designs of TAV devices; compatibility issues; and the need for individualized planning based on factors such as implant depth, shape, and coronary artery relationships. This review serves as a comprehensive guide for redo TAV, detailing the design characteristics of TAV devices, device compatibility, standardized terminology, and a structured approach for computed tomography analysis. It aims to facilitate decision making, risk identification, and achieving optimal outcomes in redo TAV procedures.


Subject(s)
Aortic Valve , Heart Valve Prosthesis , Prosthesis Design , Reoperation , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Treatment Outcome , Risk Factors , Clinical Decision-Making , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Terminology as Topic , Predictive Value of Tests
13.
JACC Cardiovasc Interv ; 17(14): 1667-1675, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39048253

ABSTRACT

BACKGROUND: Outcomes from transcatheter aortic valve replacement (TAVR) in low-surgical risk patients with bicuspid aortic stenosis beyond 2 years are limited. OBJECTIVES: This study aimed to evaluate 3-year clinical and echocardiographic outcomes from the Evolut Low Risk Bicuspid Study. METHODS: The Evolut Low Risk Bicuspid Study is a prospective, multicenter, single-arm study conducted in 25 U.S. CENTERS: Patients with severe aortic stenosis at low surgical risk with bicuspid aortic valve anatomy (all subtypes) underwent TAVR with a self-expanding, supra-annular Evolut R or PRO (Medtronic) bioprosthesis. An independent clinical events committee adjudicated all deaths and endpoint-related adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints. RESULTS: An attempted implant was performed in 150 patients from December 2018 to October 2019. The mean age was 70.3 ± 5.5 years, 48% (72/150) of the patients were women, and the mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 1.3% (Q1-Q3: 0.9%-1.7%). Sievers type 1 was the dominant bicuspid morphology (90.7%, 136/150). The Kaplan-Meier rates of all-cause mortality or disabling stroke were 1.3% (95% CI: 0.3%-5.3%) at 1 year, 3.4% (95% CI: 1.4%-8.1%) at 2 years, and 4.1% (95% CI: 1.6%-10.7%) at 3 years. The incidence of new permanent pacemaker implantation was 19.4% (95% CI: 12.4%-29.6%) at 3 years. There were no instances of moderate or severe paravalvular aortic regurgitation at 2 and 3 years after TAVR. CONCLUSIONS: The 3-year results from the Evolut Low Risk Bicuspid Study demonstrate low rates of all-cause mortality or disabling stroke and favorable hemodynamic performance.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Bicuspid Aortic Valve Disease , Bioprosthesis , Heart Valve Prosthesis , Hemodynamics , Prosthesis Design , Transcatheter Aortic Valve Replacement , Humans , Female , Male , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Risk Factors , Prospective Studies , Time Factors , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/abnormalities , Risk Assessment , Bicuspid Aortic Valve Disease/surgery , Bicuspid Aortic Valve Disease/physiopathology , United States/epidemiology , Severity of Illness Index , Postoperative Complications/mortality , Recovery of Function , Aged, 80 and over , Middle Aged , Heart Valve Diseases/physiopathology , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/surgery , Heart Valve Diseases/mortality
14.
JACC Cardiovasc Interv ; 17(14): 1680-1690, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39048255

ABSTRACT

BACKGROUND: Thromboembolic events, particularly strokes, remain a major complication of transcatheter aortic valve replacement (TAVR). Embolic protection devices have failed to show significant clinical benefit in large randomized clinical trials. Aortic wall thrombus (AWT) is often observed on multidetector computed tomography during TAVR work-up, but its prognostic significance is uncertain. OBJECTIVES: This study sought to evaluate the association between the presence of AWT and the incidence of thromboembolic outcomes in patients undergoing transfemoral (TF) TAVR for severe aortic stenosis. METHODS: This was a prospective cohort study of consecutive patients who underwent TF TAVR for severe aortic stenosis between January 2011 and April 2022. A dedicated scale (range: 0-10) was qualitatively used to assess AWT. The primary outcome was a composite of procedural thromboembolic events defined as ischemic stroke, blue toe syndrome, bowel ischemia, or other solid organ infarction. The secondary endpoints were ischemic strokes and procedural death. RESULTS: Of the 641 patients included, severe AWT (score ≥8) was identified in 73 (11.4%). The presence of severe AWT was strongly associated with an increase in the primary outcome (OR: 8.48; 95% CI: 3.36-21.40; P < 0.001). This relationship persisted following multivariable analysis, which adjusted for comorbidities and procedural characteristics. The presence of severe AWT was also found to be associated with an increased incidence of stroke and procedural death (OR: 5.66; 95% CI: 2.00-15.30; P = 0.002 and OR: 4.66; 95% CI: 1.80-11.30; P = 0.002, respectively). CONCLUSIONS: The presence of severe AWT on preprocedural multidetector computed tomography is strongly associated with thromboembolic complications including stroke and mortality after TF TAVR.


Subject(s)
Aortic Valve Stenosis , Femoral Artery , Severity of Illness Index , Thromboembolism , Thrombosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Female , Male , Aged, 80 and over , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Prospective Studies , Risk Factors , Aged , Femoral Artery/diagnostic imaging , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/mortality , Thrombosis/epidemiology , Treatment Outcome , Thromboembolism/etiology , Thromboembolism/diagnostic imaging , Thromboembolism/mortality , Thromboembolism/prevention & control , Incidence , Risk Assessment , Time Factors , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Multidetector Computed Tomography , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/mortality , Aortic Diseases/diagnostic imaging , Aortic Diseases/mortality , Punctures
18.
Echocardiography ; 41(8): e15892, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39023286

ABSTRACT

PURPOSE: The extraaortic-valvular cardiac damage (EVCD) Stage has shown potential for risk stratification for patients with aortic stenosis (AS). This study aimed to examine the usefulness of the EVCD Stage in risk stratification of patients with moderate AS and reduced left ventricular ejection fraction (LVEF). METHODS: Clinical data from patients with moderate AS (aortic valve area, .60-.85 cm2/m2; peak aortic valve velocity, 2.0-4.0 m/s) and reduced LVEF (LVEF 20%-50%) were analyzed during 2010-2019. Patients were categorized into three groups: EVCD Stages 1 (LV damage), 2 (left atrium and/or mitral valve damage), and 3/4 (pulmonary artery vasculature and/or tricuspid valve damage or right ventricular damage). The primary endpoint included a composite of cardiac death and heart failure hospitalization, with non-cardiac death as a competing risk. RESULTS: The study included 130 patients (mean age 76.4 ± 6.8 years; 62.3% men). They were categorized into three groups: 26 (20.0%) in EVCD Stage 1, 66 (50.8%) in Stage 2, and 48 (29.2%) in Stage 3/4. The endpoint occurred in 54 (41.5%) patients during a median follow-up of 3.2 years (interquartile range, 1.4-5.1). Multivariate analysis indicated EVCD Stage 3/4 was significantly associated with the endpoint (hazard ratio 2.784; 95% confidence interval 1.197-6.476; P = .017) compared to Stage 1, while Stage 2 did not (hazard ratio 1.340; 95% confidence interval .577-3.115; P = .500). CONCLUSION: The EVCD staging system may aid in the risk stratification of patients with moderate AS and reduced LVEF.


Subject(s)
Aortic Valve Stenosis , Stroke Volume , Humans , Male , Female , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/complications , Aged , Stroke Volume/physiology , Prognosis , Echocardiography/methods , Risk Assessment/methods , Retrospective Studies , Severity of Illness Index , Ventricular Function, Left/physiology , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Ventricular Dysfunction, Left/physiopathology , Ventricular Dysfunction, Left/etiology , Ventricular Dysfunction, Left/diagnostic imaging , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology
20.
JACC Cardiovasc Interv ; 17(13): 1597-1606, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38986659

ABSTRACT

BACKGROUND: Severe pure aortic regurgitation (AR) carries a high mortality and morbidity risk, and it is often undertreated because of the inherent surgical risk. Transcatheter heart valves (THVs) have been used off-label in this setting with overall suboptimal results. The dedicated "purpose-built" Jena Valve Trilogy (JVT, JenaValve Technology) showed an encouraging performance, although it has never been compared to other THVs. OBJECTIVES: The aim of our study was to assess the performance of the latest iteration of THVs used off-label in comparison to the purpose-built JVT in inoperable patients with severe AR. METHODS: We performed a multicenter, retrospective registry with 18 participating centers worldwide collecting data on inoperable patients with severe AR of the native valve. A bicuspid aortic valve was the main exclusion criterion. The primary endpoints were technical and device success, 1-year all-cause mortality, and the composite of 1-year mortality and the heart failure rehospitalization rate. RESULTS: Overall, 256 patients were enrolled. THVs used off-label were used in 168 cases (66%), whereas JVT was used in 88 (34%). JVT had higher technical (81% vs 98%; P < 0.001) and device success rates (73% vs 95%; P < 0.001), primarily driven by significantly lower incidences of THV embolization (15% vs 1.1%; P < 0.001), the need for a second valve (11% vs 1.1%; P = 0.004), and moderate residual AR (10% vs 1.1%; P = 0.007). The permanent pacemaker implantation rate was comparable and elevated for both groups (22% vs 24%; P = 0.70). Finally, no significant difference was observed at the 1-year follow-up in terms of mortality (HR: 0.99; P = 0.980) and the composite endpoint (HR: 1.5; P = 0.355). CONCLUSIONS: The JVT platform has a better acute performance than other THVs when used off-label for inoperable patients with severe AR. A longer follow-up is conceivably needed to detect a possible impact on prognosis.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve , Heart Valve Prosthesis , Prosthesis Design , Registries , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Female , Male , Retrospective Studies , Aged , Treatment Outcome , Aged, 80 and over , Risk Factors , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Patient Readmission , Recovery of Function , Europe , Heart Failure/mortality , Heart Failure/therapy , Heart Failure/physiopathology , Heart Failure/diagnosis , Hemodynamics
SELECTION OF CITATIONS
SEARCH DETAIL