Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 9.507
1.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Article En | MEDLINE | ID: mdl-38866455

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Aortic Valve Stenosis , Aortic Valve , Cardiac Pacing, Artificial , Heart Valve Prosthesis , Pacemaker, Artificial , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Male , Female , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Risk Factors , Aged , Time Factors , Aged, 80 and over , Treatment Outcome , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Risk Assessment , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/mortality , United States/epidemiology
4.
Comput Methods Programs Biomed ; 253: 108239, 2024 Aug.
Article En | MEDLINE | ID: mdl-38823116

BACKGROUND: The excitable gap (EG), defined as the excitable tissue between two subsequent wavefronts of depolarization, is critical for maintaining reentry that underlies deadly ventricular arrhythmias. EG in the His-Purkinje Network (HPN) plays an important role in the maintenance of electrical wave reentry that underlies these arrhythmias. OBJECTIVE: To determine if rapid His bundle pacing (HBP) during reentry reduces the amount of EG in the HPN and ventricular myocardium to suppress reentry maintenance and/or improve defibrillation efficacy. METHODS: In a virtual human biventricular model, reentry was initiated with rapid line pacing followed by HBP delivered for 3, 6, or 9 s at pacing cycle lengths (PCLs) ranging from 10 to 300 ms (n=30). EG was calculated independently for the HPN and myocardium over each PCL. Defibrillation efficacy was assessed for each PCL by stimulating myocardial surface EG with delays ranging from 0.25 to 9 s (increments of 0.25 s, n=36) after the start of HBP. Defibrillation was successful if reentry terminated within 1 s after EG stimulation. This defibrillation protocol was repeated without HBP. To test the approach under different pathological conditions, all protocols were repeated in the model with right (RBBB) or left (LBBB) bundle branch block. RESULTS: Compared to without pacing, HBP for >3 seconds reduced average EG in the HPN and myocardium across a broad range of PCLs for the default, RBBB, and LBBB models. HBP >6 seconds terminated reentrant arrhythmia by converting HPN activation to a sinus rhythm behavior in the default (6/30 PCLs) and RBBB (7/30 PCLs) models. Myocardial EG stimulation during HBP increased the number of successful defibrillation attempts by 3%-19% for 30/30 PCLs in the default model, 3%-6% for 14/30 PCLs in the RBBB model, and 3%-11% for 27/30 PCLs in the LBBB model. CONCLUSION: HBP can reduce the amount of excitable gap and suppress reentry maintenance in the HPN and myocardium. HBP can also improve the efficacy of low-energy defibrillation approaches targeting excitable myocardium. HBP during reentrant arrhythmias is a promising anti-arrhythmic and defibrillation strategy.


Bundle of His , Humans , Bundle of His/physiopathology , Arrhythmias, Cardiac/therapy , Cardiac Pacing, Artificial/methods , Electric Countershock/methods , Heart Ventricles/physiopathology , Models, Cardiovascular
5.
Adv Exp Med Biol ; 1441: 1023-1031, 2024.
Article En | MEDLINE | ID: mdl-38884767

The electrocardiogram (ECG) is one of the cornerstones of diagnostic investigations in pediatric or adult cardiology. The standard ECG includes 12 leads; there are 6 leads that are derived from electrodes from the arms and legs (Einthoven and Goldberger leads) and 6 precordial leads (Wilson leads).


Arrhythmias, Cardiac , Electrocardiography , Humans , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/physiopathology , Electrocardiography/methods , Child , Adult
6.
Europace ; 26(6)2024 Jun 03.
Article En | MEDLINE | ID: mdl-38848447

Pulsed field ablation (PFA) is an innovative approach in the field of cardiac electrophysiology aimed at treating cardiac arrhythmias. Unlike traditional catheter ablation energies, which use radiofrequency or cryothermal energy to create lesions in the heart, PFA utilizes pulsed electric fields to induce irreversible electroporation, leading to targeted tissue destruction. This state-of-the-art review summarizes biophysical principles and clinical applications of PFA, highlighting its potential advantages over conventional ablation methods. Clinical data of contemporary PFA devices are discussed, which combine predictable procedural outcomes and a reduced risk of thermal collateral damage. Overall, these technological developments have propelled the rapid evolution of contemporary PFA catheters, with future advancements potentially impacting patient care.


Arrhythmias, Cardiac , Humans , Arrhythmias, Cardiac/surgery , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnosis , Electroporation/trends , Electroporation/methods , Treatment Outcome , Forecasting , Catheter Ablation/trends , Catheter Ablation/methods , Ablation Techniques/trends , Cardiac Catheters , Animals
7.
Medicina (Kaunas) ; 60(5)2024 May 16.
Article En | MEDLINE | ID: mdl-38793002

Over the past decade, remote monitoring (RM) has become an increasingly popular way to improve healthcare and health outcomes. Modern cardiac implantable electronic devices (CIEDs) are capable of recording an increasing amount of data related to CIED function, arrhythmias, physiological status and hemodynamic parameters, providing in-depth and updated information on patient cardiovascular function. The extensive use of RM for patients with CIED allows for early diagnosis and rapid assessment of relevant issues, both clinical and technical, as well as replacing outpatient follow-up improving overall management without compromise safety. This approach is recommended by current guidelines for all eligible patients affected by different chronic cardiac conditions including either brady- and tachy-arrhythmias and heart failure. Beyond to clinical advantages, RM has demonstrated cost-effectiveness and is associated with elevated levels of patient satisfaction. Future perspectives include improving security, interoperability and diagnostic power as well as to engage patients with digital health technology. This review aims to update existing data concerning clinical outcomes in patients managed with RM in the wide spectrum of cardiac arrhythmias and Hear Failure (HF), disclosing also about safety, effectiveness, patient satisfaction and cost-saving.


Heart Failure , Humans , Heart Failure/therapy , Heart Failure/diagnosis , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Monitoring, Physiologic/methods , Telemedicine/trends , Defibrillators, Implantable/standards
8.
J Am Coll Cardiol ; 83(22): 2214-2232, 2024 Jun 04.
Article En | MEDLINE | ID: mdl-38811098

Arrhythmias frequently accompany heart failure and left ventricular dysfunction. Tachycardias, atrial fibrillation, and premature ventricular contractions can induce a reversible form of dilated cardiomyopathy (CM) known as arrhythmia-induced CM (AiCM). The intriguing question is why certain individuals are more susceptible to AiCM, despite similar arrhythmia burdens. The primary challenge is determining the extent of arrhythmias' contribution to left ventricular systolic dysfunction. AiCM should be considered in patients with a mean heart rate of >100 beats/min, atrial fibrillation, or a PVC burden of >10%. Confirmation of AiCM occurs when CM reverses upon eliminating the responsible arrhythmia. Therapy choice depends on the specific arrhythmia, patient comorbidities, and preferences. After left ventricular function is restored, ongoing follow-up is essential if an abnormal myocardial substrate persists. Accurate diagnosis and treatment of AiCM have the potential to enhance patients' quality of life, improve clinical outcomes, and reduce hospital admissions and overall health care costs.


Arrhythmias, Cardiac , Humans , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/physiopathology , Cardiomyopathies/etiology , Cardiomyopathies/therapy , Cardiomyopathies/physiopathology , Cardiomyopathies/diagnosis , Cardiomyopathy, Dilated/therapy , Cardiomyopathy, Dilated/physiopathology , Cardiomyopathy, Dilated/etiology
10.
Europace ; 26(5)2024 May 02.
Article En | MEDLINE | ID: mdl-38696701

AIMS: Women have been historically underrepresented in implantable cardioverter-defibrillator (ICD) trials. No data on sex differences regarding subcutaneous ICDs (S-ICD) carriers have been described. Aim of our study was to investigate sex-related differences among unselected S-ICD recipients. METHODS AND RESULTS: Consecutive patients enrolled in the multicentre, international i-SUSI registry were analysed. Comparisons between sexes were performed using a 1:1 propensity matching adjusted analysis for age, body mass index (BMI), left ventricular function, and substrate. The primary outcome was the rate of appropriate shocks during follow-up. Inappropriate shocks and other device-related complications were deemed secondary outcomes. A total of 1698 patients were extracted from the i-SUSI registry; 399 (23.5%) were females. After propensity matching, two cohorts of 374 patients presenting similar baseline characteristics were analysed. Despite similar periprocedural characteristics and a matched BMI, women resulted at lower risk of conversion failure as per PRAETORIAN score (73.4% vs. 81.3%, P = 0.049). Over a median follow-up time of 26.5 [12.7-42.5] months, appropriate shocks were more common in the male cohort (rate/year 3.4% vs. 1.7%; log-rank P = 0.049), while no significant differences in device-related complications (rate/year: 6.3% vs. 5.8%; log-rank P = 0.595) and inappropriate shocks (rate/year: 4.3% vs. 3.1%; log-rank P = 0.375) were observed. After controlling for confounders, sex remained significantly associated with the primary outcome (aHR 1.648; CI 0.999-2.655, P = 0.048), while not resulting predictor of inappropriate shocks and device-related complications. CONCLUSION: In a propensity-matched cohort of S-ICD recipients, women are less likely to experience appropriate ICD therapy, while not showing higher risk of device-related complications. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT0473876.


Defibrillators, Implantable , Electric Countershock , Propensity Score , Registries , Humans , Female , Male , Middle Aged , Aged , Sex Factors , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Risk Factors , Treatment Outcome , Arrhythmias, Cardiac/therapy , Risk Assessment , Europe , Time Factors , Death, Sudden, Cardiac/prevention & control
11.
J Am Heart Assoc ; 13(11): e031632, 2024 Jun 04.
Article En | MEDLINE | ID: mdl-38804208

BACKGROUND: Pregnancy in patients with pulmonary hypertension (PH) is associated with a heightened risk of medical complications including right heart failure, pulmonary edema, and arrhythmias. Our study investigated the association between PH and these complications during delivery. METHODS AND RESULTS: The National Inpatient Sample was used to identify delivery hospitalizations from 2011 to 2020. Multivariable logistic regression was performed to study the association of PH with the primary outcomes of in-hospital medical and obstetric complications. A total of 37 482 207 delivery hospitalizations in women ≥18 years of age were identified, of which 9593 patients had PH. Pregnant patients with PH had higher incidence of complications during delivery including preeclampsia/eclampsia, arrhythmias, and pulmonary edema among others, compared with those without PH. Pregnant patients with PH also had a higher incidence of in-hospital mortality compared with those without PH (0.51% versus 0.007%). In propensity-matched analyses, PH was still significantly associated with a higher risk of in-hospital mortality (odds ratio [OR], 5.02 [95% CI, 1.82-13.90]; P=0.001), pulmonary edema (OR, 9.11 [95% CI, 6.34-13.10]; P<0.001), peripartum cardiomyopathy (OR, 1.85 [95% CI, 1.37-2.50]; P<0.001), venous thromboembolism (OR, 12.60 [95% CI, 6.04-26.10]; P<0.001), cardiac arrhythmias (OR, 6.11 [95% CI, 4.97-7.53]; P<0.001), acute kidney injury (OR, 3.72 [95% CI, 2.86-4.84]; P<0.001), preeclampsia/eclampsia (OR, 2.24 [95% CI, 1.95-2.58]; P<0.001), and acute coronary syndrome (OR, 2.01 [95% CI, 1.06-3.80]; P=0.03), compared with pregnant patients without PH. CONCLUSIONS: Delivery hospitalizations in patients with PH are associated with a high risk of mortality, pulmonary edema, peripartum cardiomyopathy, venous thromboembolism, arrhythmias, acute kidney injury, preeclampsia/eclampsia, and acute coronary syndrome.


Hospital Mortality , Hospitalization , Hypertension, Pulmonary , Pregnancy Complications, Cardiovascular , Humans , Female , Pregnancy , Hypertension, Pulmonary/epidemiology , Hypertension, Pulmonary/mortality , Hypertension, Pulmonary/therapy , Adult , United States/epidemiology , Hospitalization/statistics & numerical data , Hospitalization/trends , Pregnancy Complications, Cardiovascular/epidemiology , Pregnancy Complications, Cardiovascular/therapy , Hospital Mortality/trends , Incidence , Young Adult , Risk Factors , Retrospective Studies , Delivery, Obstetric/statistics & numerical data , Delivery, Obstetric/adverse effects , Pulmonary Edema/epidemiology , Pulmonary Edema/etiology , Pulmonary Edema/mortality , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/mortality , Risk Assessment
12.
J Am Heart Assoc ; 13(11): e032465, 2024 Jun 04.
Article En | MEDLINE | ID: mdl-38804218

BACKGROUND: New methods to identify patients who benefit from a primary prophylactic implantable cardioverter-defibrillator (ICD) are needed. T-wave alternans (TWA) has been shown to associate with arrhythmogenesis of the heart and sudden cardiac death. We hypothesized that TWA might be associated with benefit from ICD implantation in primary prevention. METHODS AND RESULTS: In the EU-CERT-ICD (European Comparative Effectiveness Research to Assess the Use of Primary Prophylactic Implantable Cardioverter-Defibrillators) study, we prospectively enrolled 2327 candidates for primary prophylactic ICD. A 24-hour Holter monitor reading was taken from all recruited patients at enrollment. TWA was assessed from Holter monitoring using the modified moving average method. Study outcomes were all-cause death, appropriate shock, and survival benefit. TWA was assessed both as a contiguous variable and as a dichotomized variable with cutoff points <47 µV and <60 µV. The final cohort included 1734 valid T-wave alternans samples, 1211 patients with ICD, and 523 control patients with conservative treatment, with a mean follow-up time of 2.3 years. TWA ≥60 µV was a predicter for a higher all-cause death in patients with an ICD on the basis of a univariate Cox regression model (hazard ratio, 1.484 [95% CI, 1.024-2.151]; P=0.0374; concordance statistic, 0.51). In multivariable models, TWA was not prognostic of death or appropriate shocks in patients with an ICD. In addition, TWA was not prognostic of death in control patients. In a propensity score-adjusted Cox regression model, TWA was not a predictor of ICD benefit. CONCLUSIONS: T-wave alternans is poorly prognostic in patients with a primary prophylactic ICD. Although it may be prognostic of life-threatening arrhythmias and sudden cardiac death in several patient populations, it does not seem to be useful in assessing benefit from ICD therapy in primary prevention among patients with an ejection fraction of ≤35%.


Death, Sudden, Cardiac , Defibrillators, Implantable , Electrocardiography, Ambulatory , Primary Prevention , Humans , Primary Prevention/methods , Male , Female , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Middle Aged , Aged , Prospective Studies , Electrocardiography, Ambulatory/methods , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Risk Assessment/methods , Risk Factors , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/prevention & control , Arrhythmias, Cardiac/mortality , Treatment Outcome , Predictive Value of Tests , Time Factors , Europe/epidemiology , Prognosis , Heart Rate/physiology
17.
Pacing Clin Electrophysiol ; 47(6): 789-801, 2024 Jun.
Article En | MEDLINE | ID: mdl-38712484

The rapid growth in computational power, sensor technology, and wearable devices has provided a solid foundation for all aspects of cardiac arrhythmia care. Artificial intelligence (AI) has been instrumental in bringing about significant changes in the prevention, risk assessment, diagnosis, and treatment of arrhythmia. This review examines the current state of AI in the diagnosis and treatment of atrial fibrillation, supraventricular arrhythmia, ventricular arrhythmia, hereditary channelopathies, and cardiac pacing. Furthermore, ChatGPT, which has gained attention recently, is addressed in this paper along with its potential applications in the field of arrhythmia. Additionally, the accuracy of arrhythmia diagnosis can be improved by identifying electrode misplacement or erroneous swapping of electrode position using AI. Remote monitoring has expanded greatly due to the emergence of contactless monitoring technology as wearable devices continue to develop and flourish. Parallel advances in AI computing power, ChatGPT, availability of large data sets, and more have greatly expanded applications in arrhythmia diagnosis, risk assessment, and treatment. More precise algorithms based on big data, personalized risk assessment, telemedicine and mobile health, smart hardware and wearables, and the exploration of rare or complex types of arrhythmia are the future direction.


Arrhythmias, Cardiac , Artificial Intelligence , Humans , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Risk Assessment
20.
Ther Umsch ; 81(2): 54-59, 2024 Apr.
Article De | MEDLINE | ID: mdl-38780211

INTRODUCTION: Arrhythmias manifest frequently in individuals with heart failure, posing a notable threat of mortality and morbidity. While the prevention of sudden cardiac death through ICD therapy remains pivotal, accurate risk stratification remains a challenging task even in 2024. Recent data underscore the early consideration of catheter ablation for ventricular tachycardias. Although antiarrhythmic drug therapy serves as an ancillary measure for symptomatic patients, it does not confer prognostic advantages. The holistic management of arrhythmias in heart failure necessitates a systematic, multidimensional approach that initiates with evidence-based medical therapy for heart failure and integrates device-based and interventional therapies. Noteworthy clinical studies have illustrated the positive prognostic impact of early rhythm control strategies, particularly catheter ablation, in individuals managing heart failure and atrial fibrillation.


Catheter Ablation , Heart Failure , Heart Failure/therapy , Heart Failure/diagnosis , Humans , Catheter Ablation/methods , Anti-Arrhythmia Agents/therapeutic use , Defibrillators, Implantable , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Prognosis , Combined Modality Therapy , Atrial Fibrillation/therapy , Atrial Fibrillation/diagnosis , Atrial Fibrillation/complications , Evidence-Based Medicine , Tachycardia, Ventricular/therapy , Tachycardia, Ventricular/diagnosis
...