Sensors (Basel) ; 24(13)2024 Jun 23.
Article in English | MEDLINE | ID: mdl-39000857

ABSTRACT

Tactile texture sensors are designed to evaluate the sensations felt when a human touches an object. Prior studies have demonstrated the necessity for these sensors to have compliant ridges on their surfaces that mimic human fingerprints. These features enable the simulation of contact phenomena, especially friction and vibration, between human fingertips and objects, enhancing the tactile sensation evaluation. However, the ridges on tactile sensors are susceptible to abrasion damage from repeated use. To date, the healing function of abraded ridges has not been proposed, and its effectiveness needs to be demonstrated. In this study, we investigated whether the signal detection capabilities of a sensor with abraded epidermal ridges could be restored by healing the ridges using polyvinyl chloride plastisol as the sensor material. We developed a prototype tactile sensor with an embedded strain gauge, which was used to repeatedly scan roughness specimens. After more than 1000 measurements, we observed significant deterioration in the sensor's output signal level. The ridges were then reshaped using a mold with a heating function, allowing the sensor to partially regain its original signal levels. This method shows potential for extending the operational lifespan of tactile texture sensors with compliant ridges.


Subject(s)
Dermatoglyphics , Touch , Humans , Touch/physiology , Fingers/physiology , Surface Properties , Biosensing Techniques/methods , Biosensing Techniques/instrumentation
2.
Sensors (Basel) ; 24(13)2024 Jun 30.
Article in English | MEDLINE | ID: mdl-39001045

ABSTRACT

Nucleic acid tests are key tools for the detection and diagnosis of many diseases. In many cases, the amplification of the nucleic acids is required to reach a detectable level. To make nucleic acid amplification tests more accessible to a point-of-care (POC) setting, isothermal amplification can be performed with a simple heating source. Although these tests are being performed in bulk reactions, the quantification is not as accurate as it would be with digital amplification. Here, we introduce the use of the vibrating sharp-tip capillary for a simple and portable system for tunable on-demand droplet generation. Because of the large range of droplet sizes possible and the tunability of the vibrating sharp-tip capillary, a high dynamic range (~2 to 6000 copies/µL) digital droplet loop-mediated isothermal amplification (ddLAMP) system has been developed. It was also noted that by changing the type of capillary on the vibrating sharp-tip capillary, the same mechanism can be used for simple and portable DNA fragmentation. With the incorporation of these elements, the present work paves the way for achieving digital nucleic acid tests in a POC setting with limited resources.


Subject(s)
Nucleic Acid Amplification Techniques , Nucleic Acid Amplification Techniques/methods , Nucleic Acid Amplification Techniques/instrumentation , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Vibration , Point-of-Care Systems , Humans , Nucleic Acids/analysis , DNA/analysis , DNA/genetics , DNA/chemistry
3.
Sensors (Basel) ; 24(13)2024 Jul 03.
Article in English | MEDLINE | ID: mdl-39001098

ABSTRACT

The quartz tuning fork (QTF) is a promising instrument for biosensor applications due to its advanced properties such as high sensitivity to physical quantities, cost-effectiveness, frequency stability, and high-quality factor. Nevertheless, the fork's small size and difficulty in modifying the prongs' surfaces limit its wide use in experimental research. Our study presents the development of a QTF immunosensor composed of three active layers: biocompatible natural melanin nanoparticles (MNPs), glutaraldehyde (GLU), and anti-IgG layers, for the detection of immunoglobulin G (IgG). Frequency shifts of QTFs after MNP functionalization, GLU activation, and anti-IgG immobilization were measured with an Asensis QTF F-master device. Using QTF immunosensors that had been modified under optimum conditions, the performance of QTF immunosensors for IgG detection was evaluated. Accordingly, a finite element method (FEM)-based model was produced using the COMSOL Multiphysics software program (COMSOL License No. 2102058) to simulate the effect of deposited layers on the QTF resonance frequency. The experimental results, which demonstrated shifts in frequency with each layer during QTF surface functionalization, corroborated the simulation model predictions. A modelling error of 0.05% was observed for the MNP-functionalized QTF biosensor compared to experimental findings. This study validated a simulation model that demonstrates the advantages of a simulation-based approach to optimize QTF biosensors, thereby reducing the need for extensive laboratory work.


Subject(s)
Biosensing Techniques , Immunoglobulin G , Melanins , Nanoparticles , Quartz , Immunoglobulin G/chemistry , Immunoglobulin G/immunology , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Nanoparticles/chemistry , Melanins/chemistry , Quartz/chemistry , Immunoassay/methods , Immunoassay/instrumentation , Computer Simulation , Antibodies, Anti-Idiotypic/immunology , Antibodies, Anti-Idiotypic/chemistry , Humans
4.
Sensors (Basel) ; 24(13)2024 Jul 03.
Article in English | MEDLINE | ID: mdl-39001101

ABSTRACT

With the development of technology, people's demand for pressure sensors with high sensitivity and a wide working range is increasing. An effective way to achieve this goal is simulating human skin. Herein, we propose a facile, low-cost, and reproducible method for preparing a skin-like multi-layer flexible pressure sensor (MFPS) device with high sensitivity (5.51 kPa-1 from 0 to 30 kPa) and wide working pressure range (0-200 kPa) by assembling carbonized fabrics and micro-wrinkle-structured Ag@rGO electrodes layer by layer. In addition, the highly imitated skin structure also provides the device with an extremely short response time (60/90 ms) and stable durability (over 3000 cycles). Importantly, we integrated multiple sensor devices into gloves to monitor finger movements and behaviors. In summary, the skin-like MFPS device has significant potential for real-time monitoring of human activities in the field of flexible wearable electronics and human-machine interaction.


Subject(s)
Cotton Fiber , Pressure , Wearable Electronic Devices , Humans , Cotton Fiber/analysis , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Electrodes , Skin , Textiles , Human Activities
5.
Cell Rep Methods ; 4(7): 100821, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39013362

ABSTRACT

Molecular tension sensors are central tools for mechanobiology studies but have limitations in interpretation. Reporting in Cell Reports Methods, Shoyer et al. discover that fluorescent protein photoswitching in concert with sensor extension may expand the use and interpretation of common force-sensing tools.


Subject(s)
Biosensing Techniques , Humans , Biosensing Techniques/methods , Biosensing Techniques/instrumentation
6.
PLoS One ; 19(6): e0301479, 2024.
Article in English | MEDLINE | ID: mdl-38861572

ABSTRACT

This article provides insights in designing a dielectrically modulated biosensor by adopting high-k stacked gate oxide proposition in a bi-metal hetero-juncture Tunnel Field Effect Transistor (BM-SO-HTFET) with Si0.6Ge0.4 source. The integrated effect of heterojunction and stacked gate oxide leads to enhanced electrical performance of the proposed device in terms of carrier mobility and suppressed leakage current. Nano-cavity engraved beneath the bi-metal gate structure across the source/channel end acts the binding site of the biomolecules to be detected. This Configuration leads to improved control of biomolecules over source/channel tunnelling rate and the same is reflected in the sensing ability of the device while extracting the ON current sensitivity (SON) of the sensor. The reported biosensor is simulated using Silvaco ATLAS calibrated simulation framework. The analysis of the device sensitivity is carried out varying dielectric constants (k) of various biomolecules, both neutral as well as charged. Our study reveals that BM-SO-HTFET with Ge mole fraction composition x = 0.4 exhibits sensitivity as high as 4.1 × 1010 for neutral biomolecules and 3.2 × 1011 for positively charged biomolecules with k = 12. Furthermore, a transient response profile for the drain current with various biomolecules is explored to determine the varying settling time. From the simulation results, it is noted that BM-SO-HTFET exhibits ON current sensitivity of 4.1 × 1010 and 3.2 × 1011 for neutral and charged biomolecules respectively. In addition to this, for highly sensitive and real time detection of biomolecules, the impact of temperature and certain non-ideal factors drifting from ideal case of fully filled cavity have also been considered to analyze its optimum sensing performance.


Subject(s)
Biosensing Techniques , Transistors, Electronic , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Oxides/chemistry , Germanium/chemistry , Silicon/chemistry
7.
Sensors (Basel) ; 24(12)2024 Jun 08.
Article in English | MEDLINE | ID: mdl-38931517

ABSTRACT

This study integrates hollow microneedle arrays (HMNA) with a novel jellyfish-shaped electrochemical sensor for the detection of key biomarkers, including uric acid (UA), glucose, and pH, in artificial interstitial fluid. The jellyfish-shaped sensor displayed linear responses in detecting UA and glucose via differential pulse voltammetry (DPV) and chronoamperometry, respectively. Notably, the open circuit potential (OCP) of the system showed a linear variation with pH changes, validating its pH-sensing capability. The sensor system demonstrates exceptional electrochemical responsiveness within the physiological concentration ranges of these biomarkers in simulated epidermis sensing applications. The detection linear ranges of UA, glucose, and pH were 0~0.8 mM, 0~7 mM, and 4.0~8.0, respectively. These findings highlight the potential of the HMNA-integrated jellyfish-shaped sensors in real-world epidermal applications for comprehensive disease diagnosis and health monitoring.


Subject(s)
Biomarkers , Biosensing Techniques , Electrochemical Techniques , Extracellular Fluid , Needles , Extracellular Fluid/chemistry , Biomarkers/analysis , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Electrochemical Techniques/instrumentation , Electrochemical Techniques/methods , Hydrogen-Ion Concentration , Glucose/analysis , Uric Acid/analysis , Animals , Humans
8.
Toxins (Basel) ; 16(6)2024 May 26.
Article in English | MEDLINE | ID: mdl-38922139

ABSTRACT

Monitoring agricultural toxins such as mycotoxins is crucial for a healthy society. High concentrations of these toxins lead to the cause of several chronic diseases; therefore, developing analytical systems for detecting/monitoring agricultural toxins is essential. These toxins are found in crops such as vegetables, fruits, food, and beverage products. Currently, screening of these toxins is mostly performed with sophisticated instrumentation such as chromatography and spectroscopy techniques. However, these techniques are very expensive and require extensive maintenance, and their availability is limited to metro cities only. Alternatively, electrochemical biomimetic sensing methodologies have progressed hugely during the last decade due to their unique advantages like point-of-care sensing, miniaturized instrumentations, and mobile/personalized monitoring systems. Specifically, affinity-based sensing strategies including immunosensors, aptasensors, and molecular imprinted polymers offer tremendous sensitivity, selectivity, and stability to the sensing system. The current review discusses the principal mechanisms and the recent developments in affinity-based sensing methodologies for the detection and continuous monitoring of mycotoxins and pesticides. The core discussion has mainly focused on the fabrication protocols, advantages, and disadvantages of affinity-based sensing systems and different exploited electrochemical transduction techniques.


Subject(s)
Biosensing Techniques , Electrochemical Techniques , Mycotoxins , Pesticides , Mycotoxins/analysis , Pesticides/analysis , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Biomimetics , Humans , Food Contamination/analysis , Biomimetic Materials/chemistry
9.
ACS Sens ; 9(6): 3296-3306, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38829039

ABSTRACT

As a facile substitute for the invasive technique of blood testing, wearable electrochemical sensors exhibit high potential for the noninvasive and real-time monitoring of biomarkers in human sweat. However, owing to enzyme specificity, the simultaneous detection of multiple biomarkers by enzymatic analysis is challenging. Moreover, sweat accumulation under sensors causes sweat contamination, which hinders real-time biomarker detection from sweat. This study reports the design and fabrication of flexible wearable electrochemical sensors containing a composite comprising Au nanorods (AuNRs) and poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) for the nonenzymatic detection of levodopa (LD) and uric acid (UA) in sweat. Each sensor was integrated with a flexible three-electrode system and a microfluidic patch for sweat sampling. AuNRs immobilized by PEG-doped PEDOT:PSS showed excellent analytical performance for LD and UA at different potentials. Thus, the newly fabricated sensors could detect LD and UA over a broad detection range with high sensitivity and showed a low limit of detection for both species. On-body assessments confirmed the ability of these sensors to simultaneously detect LD and UA in real time. Therefore, this study could open new frontiers in the fabrication of wearable electrochemical sensors for the pharmacokinetic profile tracking of LD and gout management.


Subject(s)
Bridged Bicyclo Compounds, Heterocyclic , Electrochemical Techniques , Gold , Levodopa , Polymers , Polystyrenes , Sweat , Uric Acid , Wearable Electronic Devices , Uric Acid/analysis , Humans , Levodopa/analysis , Levodopa/blood , Sweat/chemistry , Polystyrenes/chemistry , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Gold/chemistry , Bridged Bicyclo Compounds, Heterocyclic/chemistry , Polymers/chemistry , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Nanotubes/chemistry , Limit of Detection
10.
ACS Sens ; 9(6): 2705-2727, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38843307

ABSTRACT

The ultrasensitive recognition of biomarkers plays a crucial role in the precise diagnosis of diseases. Graphene-based field-effect transistors (GFET) are considered the most promising devices among the next generation of biosensors. GFET biosensors possess distinct advantages, including label-free, ease of integration and operation, and the ability to directly detect biomarkers in liquid environments. This review summarized recent advances in GFET biosensors for biomarker detection, with a focus on interface functionalization. Various sensitivity-enhancing strategies have been overviewed for GFET biosensors, from the perspective of optimizing graphene synthesis and transfer methods, refinement of surface functionalization strategies for the channel layer and gate electrode, design of biorecognition elements and reduction of nonspecific adsorption. Further, this review extensively explores GFET biosensors functionalized with antibodies, aptamers, and enzymes. It delves into sensitivity-enhancing strategies employed in the detection of biomarkers for various diseases (such as cancer, cardiovascular diseases, neurodegenerative disorders, infectious viruses, etc.) along with their application in integrated microfluidic systems. Finally, the issues and challenges in strategies for the modulation of biosensing interfaces are faced by GFET biosensors in detecting biomarkers.


Subject(s)
Biomarkers , Biosensing Techniques , Graphite , Transistors, Electronic , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Graphite/chemistry , Biomarkers/analysis , Humans
11.
ACS Sens ; 9(6): 3455-3464, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38875528

ABSTRACT

Even though significant advances have been made, there is still a lack of reliable sensors capable of noninvasively monitoring bilirubin and diagnosing jaundice as the most common neonatal disease, particularly at the point-of-care (POC) where blood sampling from infants is accompanied by serious challenges and concerns. Herein, for the first time, using an easy-to-fabricate/use assay, we demonstrate the capability of curcumin embedded within paper for noninvasive optical monitoring of bilirubin in saliva. The highly selective sensing of the developed sensor toward bilirubin is attributed to bilirubin photoisomerization under blue light exposure, which can selectively restore the bilirubin-induced quenched fluorescence of curcumin. We also fabricated an IoT-enabled hand-held optoelectronic reader to measure and quantify the fluorescence and color signals of our sensor. Clinical analysis on the saliva of 18 jaundiced infants by using our developed smart salivary sensor proved that it is amenable to be widely exploited in POC applications for bilirubin monitoring as there are good correlations between its results with those of reference methods in saliva and blood. Meeting all WHO's REASSURED criteria by our developed sensor makes it a highly promising sensor for smart noninvasive diagnosis and therapeutic monitoring of jaundice, hepatitis, and other bilirubin-induced neurologic diseases at the POC.


Subject(s)
Bilirubin , Curcumin , Jaundice , Point-of-Care Systems , Saliva , Humans , Saliva/chemistry , Bilirubin/analysis , Bilirubin/blood , Jaundice/diagnosis , Jaundice/blood , Curcumin/chemistry , Infant, Newborn , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Infant
12.
ACS Sens ; 9(6): 3017-3026, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38889364

ABSTRACT

Traumatic brain injury (TBI) is widely recognized as a global public health crisis, affecting millions of people each year, leading to permanent neurologic, emotional, and occupational disability, and highlighting the urgent need for rapid, sensitive, and early assessment. Here, we design a novel and simple lithography-free method for preparing dual-channel graphene-based field-effect transistors (G-FETs) and integrating them with microfluidic channels for simultaneously multiplexed detection of key blood TBI biomarkers: neurofilament light chain (NFL) and glial fibrillary acidic protein (GFAP). The G-FET utilizes an ingenious dual-channel electrode array design, where the source is shared between channels and the drains are independent of each other, which is the key to achieving simultaneous output of dual detection signals. At the same time, the microfluidic chip realizes microscale fluidic control and fast sample response time. This integrated detection system shows excellent sensitivity in biological fluids for the TBI biomarkers with detection limits as low as 55.63 fg/mL for NFL and 144.45 fg/mL for GFAP in phosphate-buffered saline (PBS) buffer, respectively. Finally, the clinical sample analysis shows promising performance for TBI detection, with an area under the curve (AUC) of 0.98 for the two biomarkers. And the combined dual-protein assay is also a good predictor of intracranial injury findings on computed tomography (CT) scans (AUC = 0.907). The integrated microfluidic G-FET device with a dual-signal output strategy has important potential for application in clinical practice, providing more comprehensive information for brain injury assessment.


Subject(s)
Biomarkers , Brain Injuries, Traumatic , Glial Fibrillary Acidic Protein , Brain Injuries, Traumatic/blood , Brain Injuries, Traumatic/diagnosis , Biomarkers/blood , Humans , Glial Fibrillary Acidic Protein/blood , Lab-On-A-Chip Devices , Neurofilament Proteins/blood , Neurofilament Proteins/analysis , Transistors, Electronic , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Graphite/chemistry , Limit of Detection , Biosensing Techniques/methods , Biosensing Techniques/instrumentation
13.
Anal Chim Acta ; 1312: 342761, 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38834276

ABSTRACT

BACKGROUND: Diabetes is a significant health threat, with its prevalence and burden increasing worldwide indicating its challenge for global healthcare management. To decrease the disease severity, the diabetic patients are recommended to regularly check their blood glucose levels. The conventional finger-pricking test possesses some drawbacks, including painfulness and infection risk. Nowadays, smartphone has become a part of our lives offering an important benefit in self-health monitoring. Thus, non-invasive wearable sweat glucose sensor connected with a smartphone readout is of interest for real-time glucose detection. RESULTS: Wearable sweat glucose sensing device is fabricated for self-monitoring of diabetes. This device is designed as a body strap consisting of a sensing strip and a portable potentiostat connected with a smartphone readout via Bluetooth. The sensing strip is modified by carbon nanotubes (CNTs)-cellulose nanofibers (CNFs), followed by electrodeposition of Prussian blue. To preserve the activity of glucose oxidase (GOx) immobilized on the modified sensing strip, chitosan is coated on the top layer of the electrode strip. Herein, machine learning is implemented to correlate between the electrochemical results and the nanomaterial content along with deposition cycle of prussian blue, which provide the highest current response signal. The optimized regression models provide an insight, establishing a robust framework for design of high-performance glucose sensor. SIGNIFICANCE: This wearable glucose sensing device connected with a smartphone readout offers a user-friendly platform for real-time sweat glucose monitoring. This device provides a linear range of 0.1-1.5 mM with a detection limit of 0.1 mM that is sufficient enough for distinguishing between normal and diabetes patient with a cut-off level of 0.3 mM. This platform might be an alternative tool for improving health management for diabetes patients.


Subject(s)
Biosensing Techniques , Diabetes Mellitus , Machine Learning , Smartphone , Sweat , Wearable Electronic Devices , Humans , Sweat/chemistry , Biosensing Techniques/instrumentation , Diabetes Mellitus/diagnosis , Glucose/analysis , Nanotubes, Carbon/chemistry , Glucose Oxidase/chemistry , Glucose Oxidase/metabolism , Electrochemical Techniques/instrumentation
14.
Opt Express ; 32(10): 16867-16878, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38858883

ABSTRACT

In this paper, a highly integrated terahertz (THz) biosensor is proposed and implemented, which pioneered the preparation of low-temperature gallium arsenide (LT-GaAs) thin film photoconductive antenna (PCA) on the sensor for direct generation and detection of THz waves, simplifying complex terahertz time-domain spectroscopy (THz-TDS) systems. A latch type metasurface is deposited in the detection region to produce a resonance absorption peak at 0.6 THz that is independent of polarisation. Microfluidics is utilised and automatic injection is incorporated to mitigate the experimental effects of hydrogen bond absorption of THz waves in aqueous-based environment. Additionally, cell damage is minimised by regulating the cell flow rate. The biosensor was utilised to detect the concentration of three distinct sizes of bacteria with successful results. The assay was executed as a proof of concept to detect two distinct types of breast cancer cells. Based on the experimental findings, it has been observed that the amplitude and blueshift of the resonance absorption peaks have the ability to identify and differentiate various cancer cell types. The findings of this study introduce a novel approach for developing microfluidic THz metasurface biosensors that possess exceptional levels of integration, sensitivity, and rapid label-free detection capabilities.


Subject(s)
Arsenicals , Biosensing Techniques , Gallium , Terahertz Spectroscopy , Gallium/chemistry , Arsenicals/chemistry , Biosensing Techniques/instrumentation , Terahertz Spectroscopy/instrumentation , Humans , Equipment Design , Microfluidics/instrumentation
15.
Opt Express ; 32(10): 17239-17254, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38858913

ABSTRACT

Doxorubicin (DOX) is an important drug for cancer treatment, but its clinical application is limited due to its toxicity and side effects. Therefore, detecting the concentration of DOX during treatment is crucial for enhancing efficacy and reducing side effects. In this study, the authors developed a biophotonic fiber sensor based on localized surface plasmon resonance (LSPR) with the multimode fiber (MMF)-four core fiber (FCF)-seven core fiber (SCF)-MMF-based direct-taper and anti-taper structures for the specific detection of DOX. Compared to other detection methods, it has the advantages of high sensitivity, low cost, and strong anti-interference ability. In this experiment, multi-walled carbon nanotubes (MWCNTs), cerium-oxide nanorods (CeO2-NRs), and gold nanoparticles (AuNPs) were immobilized on the probe surface to enhance the sensor's biocompatibility. MWCNTs and CeO2-NRs provided more binding sites for the fixation of AuNPs. By immobilizing AuNPs on the surface, the LSPR was stimulated by the evanescent field to detect DOX. The sensor surface was functionalized with DOX aptamers for specific detection, enhancing its specificity. The experiments demonstrated that within a linear detection range of 0-10 µM, the sensitivity of the sensor is 0.77 nm/µM, and the limit of detection (LoD) is 0.42 µM. Additionally, the probe's repeatability, reproducibility, stability, and selectivity were evaluated, indicating that the probe has high potential for detecting DOX during cancer treatment.


Subject(s)
Doxorubicin , Gold , Metal Nanoparticles , Surface Plasmon Resonance , Doxorubicin/pharmacology , Humans , Surface Plasmon Resonance/instrumentation , Gold/chemistry , Metal Nanoparticles/chemistry , Neoplasms/drug therapy , Nanotubes, Carbon/chemistry , Biosensing Techniques/instrumentation , Optical Fibers , Equipment Design , Antibiotics, Antineoplastic/analysis , Cerium/chemistry , Fiber Optic Technology/instrumentation
16.
Opt Express ; 32(11): 20024-20034, 2024 May 20.
Article in English | MEDLINE | ID: mdl-38859121

ABSTRACT

An optical fiber sensing probe using a composite sensitive film of polyacrylonitrile (PAN) nanofiber membrane and gold nanomembrane is presented for the detection of a carcinoembryonic antigen (CEA), a biomarker associated with colorectal cancer and other diseases. The probe is based on a tilted fiber Bragg grating (TFBG) with a surface plasmon resonance (SPR) gold nanomembrane and a functionalized polyacrylonitrile (PAN) PAN nanofiber coating that selectively binds to CEA molecules. The performance of the probe is evaluated by measuring the spectral shift of the TFBG resonances as a function of CEA concentration in buffer. The probe exhibits a sensitivity of 0.46 dB/(µg/ml), a low limit of detection of 505.4 ng/mL in buffer, and a good selectivity and reproducibility. The proposed probe offers a simple, cost-effective, and a novel method for CEA detection that can be potentially applied for clinical diagnosis and monitoring of CEA-related diseases.


Subject(s)
Acrylic Resins , Carcinoembryonic Antigen , Gold , Nanofibers , Optical Fibers , Surface Plasmon Resonance , Carcinoembryonic Antigen/analysis , Gold/chemistry , Nanofibers/chemistry , Surface Plasmon Resonance/instrumentation , Surface Plasmon Resonance/methods , Acrylic Resins/chemistry , Humans , Biosensing Techniques/instrumentation , Membranes, Artificial , Metal Nanoparticles/chemistry , Reproducibility of Results , Fiber Optic Technology/instrumentation
17.
Opt Express ; 32(8): 13783-13796, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38859339

ABSTRACT

The conical fiber SPR sensor is easy to manufacture and has been used in biochemical detection research, but it has the problem of structural fragility. This article proposes a spiral cone fiber SPR sensor, which introduces a spiral structure on the 76µm fiber coarse cone, achieving good coupling of the core mode into the cladding mode, and improving the physical strength and practicality of the cone-shaped fiber SPR sensor. By modifying the target protein on the surface of the sensor gold film, specific detection of ginsenoside Rg1, an active ingredient of traditional Chinese medicine ginseng, was achieved. The detection sensitivity was 0.138 nm/(µm/ml) and the detection limit was 0.22µm/ml. The proposed spiral cone fiber SPR sensor provides a new scheme for the specific detection of active ingredients in traditional Chinese medicine, which is structurally stable and physically strong.


Subject(s)
Ginsenosides , Surface Plasmon Resonance , Ginsenosides/analysis , Surface Plasmon Resonance/methods , Biosensing Techniques/instrumentation , Equipment Design , Fiber Optic Technology/instrumentation , Limit of Detection
18.
Compr Rev Food Sci Food Saf ; 23(4): e13358, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38923121

ABSTRACT

Low-cost, reliable, and efficient biosensors are crucial in detecting residual heavy metal ions (HMIs) in food products. At present, based on distance-induced localized surface plasmon resonance of noble metal nanoparticles, enzyme-mimetic reaction of nanozymes, and chelation reaction of metal chelators, the constructed optical sensors have attracted wide attention in HMIs detection. Besides, based on the enrichment and signal amplification strategy of nanomaterials on HMIs and the construction of electrochemical aptamer sensing platforms, the developed electrochemical biosensors have overcome the plague of low sensitivity, poor selectivity, and the inability of multiplexed detection in the optical strategy. Moreover, along with an in-depth discussion of these different types of biosensors, a detailed overview of the design and application of innovative devices based on these sensing principles was provided, including microfluidic systems, hydrogel-based platforms, and test strip technologies. Finally, the challenges that hinder commercial application have also been mentioned. Overall, this review aims to establish a theoretical foundation for developing accurate and reliable sensing technologies and devices for HMIs, thereby promoting the widespread application of biosensors in the detection of HMIs in food.


Subject(s)
Biosensing Techniques , Food Contamination , Metals, Heavy , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Metals, Heavy/analysis , Food Contamination/analysis , Food Analysis/methods , Food Analysis/instrumentation
19.
Nanotechnology ; 35(36)2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38838648

ABSTRACT

Ascorbic acid (AA), known as vitamin C, is a vital bioactive compound that plays a crucial role in several metabolic processes, including the synthesis of collagen and neurotransmitters, the removal of harmful free radicals, and the uptake of iron by cells in the human intestines. As a result, there is an absolute need for a highly selective, sensitive, and economically viable sensing platform for AA detection. Herein, we demonstrate a Pt-decorated MoS2for efficient detection of an AA biosensor. MoS2hollow rectangular structures were synthesized using an easy and inexpensive chemical vapor deposition approach to meet the increasing need for a reliable detection platform. The synthesized MoS2hollow rectangular structures are characterized through field effect scanning electron microscopy (FESEM), energy-dispersive spectroscopy elemental mapping, Raman spectroscopy, and x-ray photoelectron spectroscopy. We fabricate a chemiresistive biosensor based on Pt-decorated MoS2that measures AA with great precision and high sensitivity. The experiments were designed to evaluate the response of the Pt-decorated MoS2biosensor in the presence and absence of AA, and selectivity was evaluated for a variety of biomolecules, and it was observed to be very selective towards AA. The Pt-MoS2device had a higher response of 125% against 1 mM concentration of AA biomolecules, when compared to that of all other devices and 2.2 times higher than that of the pristine MoS2device. The outcomes of this study demonstrate the efficacy of Pt-decorated MoS2as a promising material for AA detection. This research contributes to the ongoing efforts to enhance our capabilities in monitoring and detecting AA, fostering advancements in environmental, biomedical, and industrial applications.


Subject(s)
Ascorbic Acid , Biosensing Techniques , Disulfides , Molybdenum , Platinum , Ascorbic Acid/analysis , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Disulfides/chemistry , Molybdenum/chemistry , Platinum/chemistry , Humans , Spectrum Analysis, Raman/methods
20.
Anal Chem ; 96(24): 9780-9789, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38848497

ABSTRACT

Dental caries is one of the most common diseases affecting more than 2 billion people's health worldwide. In a clinical setting, it is challenging to predict and proactively guard against dental cavities prior to receiving a confirmed diagnosis. Streptococcus mutans (S. mutans) in saliva has been recognized as the main causative bacterial agent that causes dental caries. High sensitivity, good selectivity, and a wide detection range are incredibly important factors to affect S. mutans detection in practical applications. In this study, we present a portable saliva biosensor designed for the early detection of S. mutans with the potential to predict the occurrence of dental cavities. The biosensor was fabricated using a S. mutans-specific DNA aptamer and S. mutans-imprinted polymers. Methylene blue was utilized as a redox probe in the sensor to generate current signals for analysis. When S. mutans enters complementarily S. mutans cavities, it blocks electron transfer between methylene blue and the electrode, resulting in decreases in the reduction current signal. The signal variations are associated with S. mutans concentrations that are useful for quantitative analysis. The linear detection range of S. mutans is 102-109 cfu mL-1, which covers the critical concentration of high caries risk. The biosensor exhibited excellent selectivity toward S. mutans in the presence of other common oral bacteria. The biosensor's wide detection range, excellent selectivity, and low limit of detection (2.6 cfu mL-1) are attributed to the synergistic effect of aptamer and S. mutans-imprinted polymers. The sensor demonstrates the potential to prevent dental caries.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Dental Caries , Saliva , Streptococcus mutans , Saliva/microbiology , Saliva/chemistry , Streptococcus mutans/isolation & purification , Biosensing Techniques/instrumentation , Dental Caries/diagnosis , Dental Caries/microbiology , Aptamers, Nucleotide/chemistry , Humans , Methylene Blue/chemistry , Electrochemical Techniques/instrumentation
SELECTION OF CITATIONS