2.
JACC Heart Fail ; 12(7): 1141-1156, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38960519

ABSTRACT

Heart failure is a clinical syndrome characterized by the inability of the heart to meet the circulatory demands of the body without requiring an increase in intracardiac pressures at rest or with exertion. Hemodynamic parameters can be measured via right heart catheterization, which has an integral role in the full spectrum of heart failure: from ambulatory patients to those in cardiogenic shock, as well as patients being considered for left ventricular device therapy and heart transplantation. Hemodynamic data are critical for prompt recognition of clinical deterioration, assessment of prognosis, and guidance of treatment decisions. This review is a field guide for hemodynamic assessment, troubleshooting, and interpretation for clinicians treating patients with heart failure.


Subject(s)
Cardiac Catheterization , Heart Failure , Hemodynamics , Humans , Heart Failure/physiopathology , Heart Failure/therapy , Heart Failure/diagnosis , Cardiac Catheterization/methods , Hemodynamics/physiology
4.
Ann Card Anaesth ; 27(3): 220-227, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38963356

ABSTRACT

CONTEXT: Left atrial appendage closure (LAAC) was developed as a novel stroke prevention alternative for patients with atrial fibrillation, particularly for those not suitable for long-term oral anticoagulant therapy. Traditionally, general anesthesia (GA) has been more commonly used primarily due to the necessity of transesophageal echocardiography. AIMS: Compare trends of monitored anesthesia care (MAC) versus GA for percutaneous transcatheter LAAC with endocardial implant and assess for independent variables associated with primary anesthetic choice. SETTINGS AND DESIGN: Multi-institutional data collected from across the United States using the National Anesthesia Clinical Outcomes Registry. MATERIAL AND METHODS: Retrospective data analysis from 2017-2021. STATISTICAL ANALYSIS USED: Independent-sample t tests or Mann-Whitney U tests were used for continuous variables and Chi-square tests or Fisher's exact test for categorical variables. Multivariate logistic regression was used to assess patient and hospital characteristics. RESULTS: A total of 19,395 patients underwent the procedure, and 352 patients (1.8%) received MAC. MAC usage trended upward from 2017-2021 (P < 0.0001). MAC patients were more likely to have an American Society of Anesthesiologists (ASA) physical status of≥ 4 (33.6% vs 22.89%) and to have been treated at centers in the South (67.7% vs 44.2%), in rural locations (71% vs 39.5%), and with lower median annual percutaneous transcatheter LAAC volume (102 vs 153 procedures) (all P < 0.0001). In multivariate analysis, patients treated in the West had 85% lower odds of receiving MAC compared to those in the Northeast (AOR: 0.15; 95% CI 0.03-0.80, P = 0.0261). CONCLUSIONS: While GA is the most common anesthetic technique for percutaneous transcatheter closure of the left atrial appendage, a small, statistically significant increase in MAC occurred from 2017-2021. Anesthetic management for LAAC varies with geographic location.


Subject(s)
Anesthesia, General , Atrial Appendage , Atrial Fibrillation , Cardiac Catheterization , Registries , Humans , Atrial Appendage/surgery , Atrial Appendage/diagnostic imaging , Male , Female , Retrospective Studies , Aged , Cardiac Catheterization/methods , Cardiac Catheterization/statistics & numerical data , Atrial Fibrillation/surgery , Anesthesia, General/methods , Anesthesia, General/statistics & numerical data , United States , Aged, 80 and over , Middle Aged , Echocardiography, Transesophageal/methods , Treatment Outcome , Stroke/prevention & control , Stroke/epidemiology
6.
J Cardiothorac Surg ; 19(1): 403, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38943166

ABSTRACT

BACKGROUND: There is limited data on the 2-year outcomes of transapical transcatheter edge-to-edge repair (TA-TEER) using the ValveClamp in patients with severe primary mitral regurgitation (MR) and its impact on myocardial deformation. METHODS: From July 2018 to March 2021, 53 patients with symptomatic severe primary MR underwent TA-TEER were enrolled. The endpoint was the composite of all-cause mortality, recurrent 3 + or 4 + MR, or need for mitral surgery. RESULTS: Among the 53 patients who had successfully ValveClamp implantation, 8(15.1%) reached the composite endpoint. Significant improvement in left ventricular (LV) end-diastolic volume, pulmonary artery systolic pressure, NYHA functional class, and MR severity were observed (P < 0.05 for all). Univariate Cox's regression analysis revealed that LV end-diastolic volume index, LV end-systolic volume index, left atrial volume index, and pulmonary artery systolic pressure were associated with adverse events (P < 0.05 for all). On multivariate Cox regression analysis, left atrial volume index was independently associated with the endpoint (hazard ratio, 1.049; 95% CI, 1.009-1.091; P < 0.001) after adjustment for above echocardiographic parameters. LV global longitudinal strain and apical longitudinal strain in global and regional segments decreased at 30 days, but showed a recovery at 2 years with no significant difference compared to the baseline. CONCLUSION: TA-TEER using the ValveClamp presented favorable safety and efficacy at 2-year. Myocardial deformation impairment was observed at 30 days post-procedure, but did not persist at 2 years.


Subject(s)
Mitral Valve Insufficiency , Mitral Valve , Humans , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Male , Female , Aged , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Middle Aged , Heart Valve Prosthesis Implantation/methods , Treatment Outcome , Echocardiography , Retrospective Studies , Cardiac Catheterization/methods
8.
Clin Res Cardiol ; 113(7): 1081-1091, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38832995

ABSTRACT

BACKGROUND: Despite the recommendation of coronary physiology to guide revascularization in angiographically intermediate stenoses without established correlation to ischemia, its uptake in clinical practice is slow. AIMS: This study aimed to analyze the use of coronary physiology in clinical practice. METHODS: Based on a multicenter registry (Fractional Flow Reserve Fax Registry, F(FR)2, ClinicalTrials.gov identifier NCT03055910), clinical use, consequences, and complications of coronary physiology were systematically analyzed. RESULTS: F(FR)2 enrolled 2,000 patients with 3,378 intracoronary pressure measurements. Most measurements (96.8%) were performed in angiographically intermediate stenoses. Out of 3,238 lesions in which coronary physiology was used to guide revascularization, revascularization was deferred in 2,643 (78.2%) cases. Fractional flow reserve (FFR) was the most common pressure index used (87.6%), with hyperemia induced by an intracoronary bolus of adenosine in 2,556 lesions (86.4%) and intravenous adenosine used for 384 measurements (13.0%). The route of adenosine administration did not influence FFR results (change-in-estimate -3.1% for regression model predicting FFR from diameter stenosis). Agreement with the subsequent revascularization decision was 93.4% for intravenous and 95.0% for intracoronary adenosine (p = 0.261). Coronary artery occlusion caused by the pressure wire was reported in two cases (0.1%) and dissection in three cases (0.2%), which was fatal once (0.1%). CONCLUSIONS: In clinical practice, intracoronary pressure measurements are mostly used to guide revascularization decisions in angiographically intermediate stenoses. Intracoronary and intravenous administration of adenosine seem equally suited. While the rate of serious complications of wire-based intracoronary pressure measurements in clinical practice seems to be low, it is not negligible.


Subject(s)
Coronary Angiography , Coronary Stenosis , Coronary Vessels , Fractional Flow Reserve, Myocardial , Registries , Humans , Fractional Flow Reserve, Myocardial/physiology , Male , Female , Coronary Stenosis/physiopathology , Coronary Stenosis/diagnosis , Middle Aged , Coronary Vessels/physiopathology , Coronary Vessels/diagnostic imaging , Aged , Adenosine/administration & dosage , Myocardial Revascularization/methods , Cardiac Catheterization/methods , Vasodilator Agents/administration & dosage
10.
Interv Cardiol Clin ; 13(3): 385-398, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38839171

ABSTRACT

Congenital heart disease (CHD) is the most common congenital birth defect with an incidence of 1 in 100. Current survival to adulthood is expected in 9 out of 10 children with severe CHD as the diagnostic, interventional, and surgical success improves. The adult CHD (ACHD) population is increasingly diverse, reflecting the broad spectrum of CHD and evolution of surgical techniques to improve survival. Similarly, transcatheter interventions have seen exponential growth and creativity to reduce the need for repeat sternotomies. This article focuses on newer data and evolving techniques for transcatheter interventions specific to certain ACHD populations.


Subject(s)
Cardiac Catheterization , Heart Defects, Congenital , Humans , Heart Defects, Congenital/surgery , Cardiac Catheterization/methods , Adult , Cardiac Surgical Procedures/methods
11.
Interv Cardiol Clin ; 13(3): 369-384, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38839170

ABSTRACT

Over the last 2 decades, experience with transcatheter pulmonary valve replacement (TPVR) has grown significantly and has become an effective and reliable way of treating pulmonary valve regurgitation, right ventricular outflow (RVOT) obstruction, and dysfunctional bioprosthetic valves and conduits. With the introduction of self-expanding valves and prestents, dilated native RVOT can be addressed with the transcatheter approach. In this article, the authors review the current practices, technical challenges, and outcomes of TPVR.


Subject(s)
Cardiac Catheterization , Heart Defects, Congenital , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Humans , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/methods , Pulmonary Valve/surgery , Heart Defects, Congenital/surgery , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/diagnosis , Ventricular Outflow Obstruction/surgery , Prosthesis Design , Bioprosthesis
12.
Interv Cardiol Clin ; 13(3): 355-368, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38839169

ABSTRACT

Transcatheter ductal closure has proven to be safe and effective to occlude the patent ductus arteriosus (PDA) in premature infants. We have developed a robust multidisciplinary PDA program. After gaining experience performing transcatheter ductal closure in the cardiac catheterization laboratory, we transitioned to performing the procedure at the patient's bedside in the neonatal intensive care unit using echocardiographic guidance. The bedside approach has the potential to expand this therapy to patients who currently undergo expectant PDA management because of lack of availability of this therapy, and allow for earlier referral, which will reduce time of exposure to this pathologic shunt.


Subject(s)
Cardiac Catheterization , Ductus Arteriosus, Patent , Infant, Premature , Humans , Ductus Arteriosus, Patent/surgery , Ductus Arteriosus, Patent/diagnosis , Infant, Newborn , Cardiac Catheterization/methods , Septal Occluder Device , Echocardiography/methods
13.
EuroIntervention ; 20(11): e718-e727, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38840576

ABSTRACT

BACKGROUND: Left atrial appendage occlusion (LAAO) is performed increasingly, but long-term follow-up imaging data are lacking. AIMS: The aim of this study was to evaluate the safety and durability of the Amplatzer Amulet device >4 years after LAAO. METHODS: This was a prospective observational cohort study including 52 patients implanted with the Amplatzer Amulet device at Aarhus University Hospital, Denmark. A >4-year follow-up cardiac computed tomography (CT) scan after LAAO was performed and compared with the results from the 2-month and 12-month scans. The primary outcome was left atrial appendage (LAA) sealing based on distal LAA contrast patency and peridevice leakage (PDL), stratified into complete occlusion (grade 0 [G0]) and grade 1-3 leakage (G1-3), respectively. Secondary outcomes were low- and high-grade hypoattenuated thickening (HAT), device-related thrombosis (DRT) and device durability. RESULTS: The median (interquartile range [IQR]) follow-up time from LAAO to the latest CT scan was 5.8 years (4.5; 6.3). At 2-month (n=52), 12-month (n=27) and >4-year CT follow-ups (n=52), rates of both complete occlusion (33%, 37%, 35%) and G2 leaks (52%, 52%, 48%) remained stable. Rates of G1 leaks varied (14%, 4%, 6%) and G3 leaks rose (2%, 7%, 12%) from earliest to latest follow-up. The median left atrial (LA) volume increased from 127 mL (96; 176) to 144 mL (108; 182) and 147 mL (107; 193). No DRT was found. The structural device integrity was preserved. CONCLUSIONS: This study indicates a stable LAA sealing status throughout the follow-up period, emphasising the importance of the procedural result in avoiding PDL. Few patients displayed PDL progression, which might partly be related to LA remodelling with increasing volume. The long-term device durability appears excellent. Larger studies are warranted to confirm these findings.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Septal Occluder Device , Tomography, X-Ray Computed , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Appendage/physiopathology , Male , Female , Aged , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnostic imaging , Prospective Studies , Aged, 80 and over , Treatment Outcome , Follow-Up Studies , Middle Aged , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation
15.
Echocardiography ; 41(6): e15822, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38853621

ABSTRACT

BACKGROUND: Balloon sizing (BS) has been used for device size selection in percutaneous atrial septal defect (ASD) closure. Due to its limitations, alternative imaging techniques like three-dimensional transesophageal echocardiography (3D-TEE) are valuable for guiding ASD device size selection during ASD closure procedures. The purpose of this study was to compare ASD sizing using measurements obtained from 3D-TEE to those utilizing the standard balloon sizing method. METHODS: We identified 53 patients with single secundum type ASD without PFO who underwent percutaneous closure at the Tehran Heart Center between 2019 and 2022. Balloon sizing was performed in all patients with the stop-flow technique, and the choice of device size was determined based on the sizing derived from BS. 3D-TEE imaging was performed before the intervention, and the ASD shape and quality of ASD rims were assessed. RESULTS: Among the 53 patients who underwent single ASD device closure, multiple 3D TEE measurements significantly correlated with balloon sizing results. This included defect area, perimeter, and diameter obtained from 3D-TEE images multi-planar reconstruction. ASD perimeter detected by 3D TEE had the best correlation with BS results. When divided by the shape of ASD, there was no significant difference between our 3D-images data and BS in round or oval-shaped ASDs. CONCLUSION: The 3D-TEE study is reliable for assessing ASD configurational characteristics in percutaneous device closure candidates. 3D-TEE has the potential to accurately determine the appropriate device size and reduce complications, costs, and procedural duration. Further research is needed to validate these findings and establish the role of 3D-TEE measurements in guiding the best treatment decisions for ASD closure.


Subject(s)
Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Heart Septal Defects, Atrial , Septal Occluder Device , Humans , Echocardiography, Transesophageal/methods , Echocardiography, Three-Dimensional/methods , Male , Heart Septal Defects, Atrial/surgery , Heart Septal Defects, Atrial/diagnostic imaging , Female , Adult , Middle Aged , Adolescent , Prosthesis Design , Cardiac Catheterization/methods , Reproducibility of Results , Young Adult
16.
Echocardiography ; 41(6): e15861, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38853674

ABSTRACT

BACKGROUND: Transesophageal echocardiography (TEE) is primarily used to guide transcatheter structural heart interventions, such as tricuspid transcatheter edge-to-edge repair (TEER). Although TEE has a good safety profile, it is still an invasive imaging technique that may be associated with complications, especially when performed during long transcatheter procedures or on frail patients. The aim of this study was to assess TEE-related complications during tricuspid TEER. METHODS: This is a prospective study enrolling 53 patients who underwent tricuspid TEER for severe tricuspid regurgitation (TR). TEE-related complications were assessed clinically and divided into major (life-threatening, major bleeding requiring transfusions or surgery, organ perforation, and persistent dysphagia) and minor (perioral hypesthesia, < 24 h dysphagia/odynophagia, minor intraoral bleeding and hematemesis not requiring transfusion) RESULTS: The median age of the patient population was 79 years; 43.4% had severe, 39.6% massive, and 17.6% torrential TR. 62.3% of patients suffered from upper gastrointestinal disorders. Acute procedural success (APS) was achieved in 88.7% in a median device time of 36 min. A negative association was shown between APS and lead-induced etiology (r = -.284, p = .040), baseline TR grade (r = -.410, p = .002), suboptimal TEE view (r = -.349, p = .012), device time (r = -.234, p = .043), and leaflet detachment (r = -.496, p < .0001). We did not observe any clinical manifest major or minor TEE-related complications during the hospitalization. CONCLUSIONS: Our study reinforces the good safety profile and efficacy of TEE guidance during tricuspid TEER. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious complications. Furthermore, suboptimal intraprocedural TEE views are associated with lower TR reduction rates. HIGHLIGHTS: Transesophageal echocardiography is a crucial and safe technique for guiding transcatheter structural heart interventions. A mix of mid/deep esophageal and trans gastric views, as well as real-time 3D imaging is generally used to guide the procedure. Adequate preoperative management and intraprocedural precautions are mandatory in order to avoid serious problems. A shorter device time is associated with more rarely probe-related complications. Suboptimal intraprocedural TEE views are associated with lower TR reduction rates.


Subject(s)
Echocardiography, Transesophageal , Tricuspid Valve Insufficiency , Tricuspid Valve , Humans , Echocardiography, Transesophageal/methods , Female , Male , Prospective Studies , Tricuspid Valve Insufficiency/surgery , Aged , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects , Treatment Outcome , Aged, 80 and over
17.
J Cardiothorac Surg ; 19(1): 335, 2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38898495

ABSTRACT

BACKGROUND: Perioperative management and cardiac surgery in pregnant women with anti-phospholipid syndrome combined with heart valve disease have been rarely reported. CASE PRESENTATION: We describe a case of transcatheter mitral valve-in-valve replacement in a pregnant woman with bioprosthetic valve failure and anti-phospholipid syndrome at 18 weeks' gestation. The patient underwent a cesarean section delivery at 34 weeks of gestation, resulting in the birth of a healthy baby. CONCLUSIONS: Transapical mitral valve-in-valve surgery resulted in safe maternal and infant outcomes in a pregnant woman with anti-phospholipid syndrome combined with mitral bioprosthetic valve failure. The success of this procedure underscored the importance of multidisciplinary teamwork.


Subject(s)
Antiphospholipid Syndrome , Bioprosthesis , Heart Valve Prosthesis Implantation , Mitral Valve , Pregnancy Complications, Cardiovascular , Humans , Female , Pregnancy , Antiphospholipid Syndrome/complications , Mitral Valve/surgery , Adult , Heart Valve Prosthesis Implantation/methods , Pregnancy Complications, Cardiovascular/surgery , Heart Valve Prosthesis , Cesarean Section , Cardiac Catheterization/methods , Mitral Valve Insufficiency/surgery , Prosthesis Failure
18.
Interv Cardiol Clin ; 13(3): 291-306, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38839164

ABSTRACT

Superior sinus venosus defects (SVD) are interatrial communications located above the confines of the oval fossa, where unroofing of the right upper pulmonary vein leads to its anomalous drainage to the superior venacava. Recent emergence of transcatheter closure of these defects using covered stents is an attractive alternative option especially in adults with additional comorbidities. This article focuses on various aspects of non-surgical closure of SVD, including patient selection, appropriate hardware options, step-by-step procedural details, evolution and modifications in the techniques over the last decade, protocols for follow-up evaluation, and potential complications associated with this intervention.


Subject(s)
Cardiac Catheterization , Stents , Humans , Cardiac Catheterization/methods , Heart Septal Defects, Atrial/surgery , Prosthesis Design , Vena Cava, Superior/abnormalities , Vena Cava, Superior/surgery
19.
Interv Cardiol Clin ; 13(3): 399-408, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38839172

ABSTRACT

Hybrid interventions in congenital heart disease (CHD) embody the inherent collaboration between congenital interventional cardiology and cardiothoracic surgery. Hybrid approaches to complex and common lesions provide the opportunity to circumvent the limitations of patient size, vascular access, severity of illness, and anatomy that would otherwise be prohibitive to surgical and percutaneous techniques alone. This review describes several important hybrid approaches to interventions in CHD.


Subject(s)
Heart Defects, Congenital , Humans , Heart Defects, Congenital/surgery , Cardiac Catheterization/methods , Cardiac Surgical Procedures/methods
20.
Interv Cardiol Clin ; 13(3): 421-430, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38839174

ABSTRACT

Since PDA stenting was first attempted in the early 1990s, significant technical advancements have improved outcomes and some centers have even transitioned to exclusive PDA stenting for all infants with duct-dependent pulmonary circulation. In addition to its use in infants with duct-dependent pulmonary circulation, PDA stenting has also been adapted as a percutaneous palliative option for suprasystemic pulmonary arterial hypertension and as a component of the hybrid procedure. In this article, the authors aim to review indications and outcomes for PDA stenting, describe the procedure, and discuss future directions.


Subject(s)
Ductus Arteriosus, Patent , Stents , Humans , Ductus Arteriosus, Patent/surgery , Cardiac Catheterization/methods , Palliative Care/methods , Treatment Outcome