Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 8.614
Filter
1.
BMC Cardiovasc Disord ; 24(1): 347, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38977958

ABSTRACT

BACKGROUND: CHA2DS2-VASc score-related differences have been reported in atrial fibrotic remodeling and prognosis of atrial fibrillation (AF) patients after ablation. There are currently no data on the efficacy of low voltage zone (LVZ)-guided ablation in persistent AF patients according to CHA2DS2-VASc score. We assessed in a cohort of persistent AF patients the extent of LVZ, the regional distribution of LA voltage and the outcome of LA voltage-guided substrate ablation in addition to PVI according to CHA2DS2-VASc score. METHODS: 138 consecutive persistent AF patients undergoing a first voltage-guided catheter ablation were enrolled. 58 patients with CHAD2DS2-VASc score ≥ 3 and 80 patients with CHAD2DS2-VASc score ≤ 2 were included. LA voltage maps were obtained using 3D-electroanatomical mapping system in sinus rhythm. LVZ was defined as < 0.5 mV. RESULTS: In the high CHAD2DS2-VASc score group, LA voltage was lower (1.5 [1.1-2.5] vs. 2.3 [1.5-2.8] mV, p = 0.02) and LVZs were more frequently identified (40% vs. 18%), p < 0.01). Female with CHA2DS2-VASc score ≥ 3 (p = 0.031), LA indexed volume (p = 0.009) and P-wave duration ≥ 150 ms (p = 0.001) were predictors of LVZ. After a 36-month follow-up, atrial arrhythmia-free survival was similar between the two groups (logrank test, P = 0.676). CONCLUSIONS: AF patients with CHAD2DS2-VASc score ≥ 3 display more LA substrate remodeling with lower voltage and more LVZs compared with those with CHAD2DS2-VASc score ≤ 2. Despite this atrial remodeling, they had similar and favorable 36 months results after one single procedure. Unlike male with CHAD2DS2-VASc score ≥ 3, female with CHAD2DS2-VASc score ≥ 3 was predictor of LVZ occurrence.


Subject(s)
Action Potentials , Atrial Fibrillation , Atrial Function, Left , Atrial Remodeling , Catheter Ablation , Predictive Value of Tests , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/mortality , Female , Male , Catheter Ablation/adverse effects , Middle Aged , Aged , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Heart Atria/physiopathology , Heart Atria/surgery , Heart Rate , Decision Support Techniques , Electrophysiologic Techniques, Cardiac , Recurrence , Retrospective Studies
2.
Europace ; 26(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38864730

ABSTRACT

AIMS: Patients with structural heart disease (SHD) undergoing catheter ablation (CA) for ventricular tachycardia (VT) are at considerable risk of periprocedural complications, including acute haemodynamic decompensation (AHD). The PAINESD score was proposed to predict the risk of AHD. The goal of this study was to validate the PAINESD score using the retrospective analysis of data from a large-volume heart centre. METHODS AND RESULTS: Patients who had their first radiofrequency CA for SHD-related VT between August 2006 and December 2020 were included in the study. Procedures were mainly performed under conscious sedation. Substrate mapping/ablation was performed primarily during spontaneous rhythm or right ventricular pacing. A purposely established institutional registry for complications of invasive procedures was used to collect all periprocedural complications that were subsequently adjudicated using the source medical records. Acute haemodynamic decompensation triggered by CA procedure was defined as intraprocedural or early post-procedural (<12 h) development of acute pulmonary oedema or refractory hypotension requiring urgent intervention. The study cohort consisted of 1124 patients (age, 63 ± 13 years; males, 87%; ischaemic cardiomyopathy, 67%; electrical storm, 25%; New York Heart Association Class, 2.0 ± 1.0; left ventricular ejection fraction, 34 ± 12%; diabetes mellitus, 31%; chronic obstructive pulmonary disease, 12%). Their PAINESD score was 11.4 ± 6.6 (median, 12; interquartile range, 6-17). Acute haemodynamic decompensation complicated the CA procedure in 13/1124 = 1.2% patients and was not predicted by PAINESD score with AHD rates of 0.3, 1.8, and 1.1% in subgroups by previously published PAINESD terciles (<9, 9-14, and >14). However, the PAINESD score strongly predicted mortality during the follow-up. CONCLUSION: Primarily substrate-based CA of SHD-related VT performed under conscious sedation is associated with a substantially lower rate of AHD than previously reported. The PAINESD score did not predict these events. The application of the PAINESD score to the selection of patients for pre-emptive mechanical circulatory support should be reconsidered.


Subject(s)
Catheter Ablation , Hemodynamics , Tachycardia, Ventricular , Humans , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/diagnosis , Male , Female , Middle Aged , Catheter Ablation/adverse effects , Retrospective Studies , Cicatrix/physiopathology , Aged , Hypotension/etiology , Hypotension/physiopathology , Hypotension/diagnosis , Pulmonary Edema/etiology , Pulmonary Edema/diagnosis , Pulmonary Edema/physiopathology , Postoperative Complications/etiology , Postoperative Complications/diagnosis , Risk Factors
3.
J Am Heart Assoc ; 13(12): e033969, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38879457

ABSTRACT

BACKGROUND: A lower serum eicosapentaenoic acid (EPA) to arachidonic acid (AA) ratio (EPA/AA) level correlates with cardiovascular events. Nevertheless, elevated serum EPA levels increase the risk of new-onset atrial fibrillation (AF) in older patients. The relationship between the EPA/AA and outcomes post-AF ablation remains unclear. This study investigated the impact of the EPA/AA on AF recurrence and cardiovascular events after AF ablation in older patients. METHODS AND RESULTS: This retrospective cohort study examined consecutive patients with AF aged ≥65 years who underwent a first-time AF ablation. We compared the 3-year AF recurrence and 5-year major adverse cardiovascular event (MACE) rates between patients divided into high and low EPA/AA levels defined as above and below the median EPA/AA value before ablation. MACE was defined as heart failure hospitalizations, strokes, coronary artery disease, major bleeding, and cardiovascular death. Among the 673 included patients, the median EPA/AA value was 0.35. Compared with the low EPA/AA group, the high EPA/AA group had a significantly higher cumulative incidence of AF recurrence (39.3% versus 27.6%; log-rank P=0.004) and lower cumulative incidence of MACE (13.8% versus 25.5%, log-rank P=0.021). A high EPA/AA level was determined as an independent predictor of AF recurrence (hazard ratio [HR], 1.75 95% CI, 1.24-2.49; P=0.002) and MACE (HR, 0.60 [95% CI, 0.36-0.99]; P=0.046). CONCLUSIONS: The EPA/AA was associated with AF recurrence and MACE after ablation in patients with AF aged ≥65 years.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Eicosapentaenoic Acid , Recurrence , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/blood , Eicosapentaenoic Acid/blood , Male , Female , Aged , Retrospective Studies , Catheter Ablation/adverse effects , Treatment Outcome , Arachidonic Acid/blood , Risk Factors , Age Factors , Time Factors , Biomarkers/blood , Aged, 80 and over
4.
BMC Cardiovasc Disord ; 24(1): 321, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38918704

ABSTRACT

BACKGROUND: Catheter ablation and antiarrhythmic drug therapy are utilized for rhythm control in atrial fibrillation (AF), but their comparative effectiveness, especially with contemporary treatment modalities, remains undefined. We conducted a systematic review and meta-analysis contrasting current ablation techniques against antiarrhythmic medications for AF. METHODS: We searched PubMed, SCOPUS, Cochrane CENTRAL, and Web of Science until November 2023 for randomized trials comparing AF catheter ablation with antiarrhythmics, against antiarrhythmic drug therapy alone, reporting outcomes for > 6 months. Four investigators extracted data and appraised risk of bias (ROB) with ROB 2 tool. Meta-analyses estimated pooled efficacy and safety outcomes using R software. RESULTS: Twelve trials (n = 3977) met the inclusion criteria. Catheter ablation was associated with lower AF recurrence (relative risk (RR) = 0.44, 95%CI (0.33, 0.59), P ˂ 0.0001) and hospitalizations (RR = 0.44, 95%CI (0.23, 0.82), P = 0.009) than antiarrhythmic medications. Catheter ablation also improved the physical quality of life component score (assessed by a 36-item Short Form survey) by 7.61 points (95%CI -0.70-15.92, P = 0.07); but, due to high heterogeneity, it was not statistically significant. Ablation was significantly associated with higher procedural-related complications [RR = 15.70, 95%CI (4.53, 54.38), P < 0.0001] and cardiac tamponade [RR = 9.22, 95%CI (2.16, 39.40), P = 0.0027]. All-cause mortality was similar between the two groups. CONCLUSIONS: For symptomatic AF, upfront catheter ablation reduces arrhythmia and hospitalizations better than continued medical therapy alone, albeit with moderately more adverse events. Careful patient selection and risk-benefit assessment are warranted regarding the timing of ablation.


Subject(s)
Anti-Arrhythmia Agents , Atrial Fibrillation , Catheter Ablation , Recurrence , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/drug therapy , Atrial Fibrillation/mortality , Atrial Fibrillation/therapy , Catheter Ablation/adverse effects , Anti-Arrhythmia Agents/therapeutic use , Anti-Arrhythmia Agents/adverse effects , Treatment Outcome , Risk Factors , Middle Aged , Female , Male , Heart Rate/drug effects , Aged , Quality of Life , Time Factors , Risk Assessment , Randomized Controlled Trials as Topic
5.
J Cardiothorac Surg ; 19(1): 344, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38907311

ABSTRACT

BACKGROUND: In this study we investigated the impact of ABC stroke score on the recurrence of paroxysmal atrial fibrillation (PAF) following radiofrequency catheter ablation (RFCA). METHODS: A total of 132 patients with PAF who underwent RFCA from October 2018 to September 2019 were included in this study. During the first phase of this study the patients were categorized into two groups based on late recurrence of atrial fibrillation after RFCA. In the second phase, the patients were further divided into two groups based on whether their ABC stroke score was ≥ 6.5. RESULT: The univariate analysis indicated that the risk factors for late recurrence of PAF included early recurrence, ABC stroke score, CHA2DS2-VASc score, and NT-proBNP (P < 0.05). Cox multivariate regression analysis revealed that ABC stroke score (P = 0.006) and early recurrence (P = 0.000) were independent predictors of late recurrence, and ABC stroke score ≥ 6.5 was a risk for predicting recurrence of PAF after RFCA with a sensitivity of 66.7% and specificity of 65.7%. After the completion of the 1:1 matching, the univariate Cox analysis indicated that an elevated score of ABC stroke (≥ 6.5) was an independent predictor of late recurrence of PAF (HR = 2.687, 95% CI: 1.036-6.971, P = 0.042). However, using an ABC stroke score cut off at 6.4 predicted the recurrence of atrial tachyarrhythmia with 85% sensitivity and 58.5% specificity. CONCLUSION: An ABC stroke score ≥ 6.4 is a predictor for late recurrence of PAF after RFCA.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Recurrence , Stroke , Humans , Atrial Fibrillation/surgery , Male , Female , Catheter Ablation/adverse effects , Middle Aged , Stroke/etiology , Risk Factors , Retrospective Studies , Aged , Risk Assessment/methods , Postoperative Complications/diagnosis , Postoperative Complications/etiology
6.
BMC Cardiovasc Disord ; 24(1): 316, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38910261

ABSTRACT

BACKGROUND AND AIMS: Electrophysiological characteristics and radiofrequency catheter ablation (RFCA) of premature ventricular contractions (PVCs) originating from the superior septal left ventricle (SSLV) have not yet been fully characterized. METHODS AND RESULTS: This study included 247 patients who underwent RFCA for PVCs arising from the ventricular outflow tract between February 2020 and August 2022. The successful ablation site was on the SSLV in 37 of the 247 patients. In 12 (32.4%) of those 37 patients, a low amplitude and high frequency spiky potential (SP) was recognized. Five patients showed a narrow QRS duration (86.8 ± 4.6 ms), with a discrete SP observed in PVCs and sinus rhythm, which showed an isoelectric line with the ventricular electrogram at the earliest activation site. Seven patients showed a wide QRS duration (131.6 ± 4.5 ms), with SP observed in PVCs without an isoelectric line with the ventricular electrogram. RFCA was successful at the site of the earliest SP in all 12 patients. The time from SP onset at the successful ablation site to the QRS onset (local activation time) was 30 ± 12 ms, which differed significantly from that for the remaining 25 patients withoutSP(22.1 ± 7.1 ms, P < 0.05). CONCLUSIONS: SPs were recorded in 12 (32.4%) of the 37 patients with PVCs originating from the SSLV. The morphology of the PVCs may show a narrow or wide QRS duration and the target site for successful ablation should be identified by the earliest SP.


Subject(s)
Action Potentials , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Heart Rate , Ventricular Premature Complexes , Humans , Catheter Ablation/adverse effects , Ventricular Premature Complexes/physiopathology , Ventricular Premature Complexes/surgery , Ventricular Premature Complexes/diagnosis , Male , Female , Middle Aged , Treatment Outcome , Adult , Time Factors , Retrospective Studies , Aged , Electrocardiography
7.
Europace ; 26(7)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38912887

ABSTRACT

AIMS: Pulsed field ablation (PFA) is an emerging non-thermal ablative modality demonstrating considerable promise for catheter ablation of atrial fibrillation (AF). However, these PFA trials have almost universally included only Caucasian populations, with little data on its effect on other races/ethnicities. The PLEASE-AF trial sought to study the 12-month efficacy and the safety of a multi-electrode hexaspline PFA catheter in treating a predominantly Asian/Chinese population of patients with drug-refractory paroxysmal AF. METHODS AND RESULTS: Patients underwent pulmonary vein (PV) isolation (PVI) by delivering different pulse intensities at the PV ostium (1800 V) and atrium (2000 V). Acute success was defined as no PV potentials and entrance/exit conduction block of all PVs after a 20-min waiting period. Follow-up at 3, 6, and 12 months included 12-lead electrocardiogram and 24-h Holter examinations. The primary efficacy endpoint was 12-month freedom from any atrial arrhythmias lasting at least 30 s. The cohort included 143 patients from 12 hospitals treated by 28 operators: age 60.2 ± 10.0 years, 65.7% male, Asian/Chinese 100%, and left atrial diameter 36.6 ± 4.9 mm. All PVs (565/565, 100%) were successfully isolated. The total procedure, catheter dwell, total PFA application, and total fluoroscopy times were 123.5 ± 38.8 min, 63.0 ± 30.7 min, 169.7 ± 34.6 s, and 27.3 ± 10.1 min, respectively. The primary endpoint was observed in 124 of 143 patients (86.7%). One patient (0.7%) developed a small pericardial effusion 1-month post-procedure, not requiring intervention. CONCLUSION: The novel hexaspline PFA catheter demonstrated universal acute PVI with an excellent safety profile and promising 12-month freedom from recurrent atrial arrhythmias in an Asian/Chinese population with paroxysmal AF. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05114954.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Male , Female , Middle Aged , Catheter Ablation/methods , Catheter Ablation/adverse effects , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Aged , Treatment Outcome , Asian People , China , Cardiac Catheters , Recurrence , Electrocardiography, Ambulatory , Time Factors , Equipment Design , Heart Rate , Action Potentials
8.
Lakartidningen ; 1212024 Jun 04.
Article in Swedish | MEDLINE | ID: mdl-38832571

ABSTRACT

Ventricular tachycardia (VT) in patients with structural heart disease is potentially life threatening, and most patients have an indication for an implantable cardioverter-defibrillator (ICD). Catheter ablation is an effective therapeutic strategy to reduce the risk of VT recurrence and subsequent ICD therapies. However, VT ablation is a technically complex procedure with significant risks and should be performed in experienced centers with appropriate resources. While several reports on outcome and procedural risks have been published, there is currently no data from Sweden. In addition to this literature review, we have analyzed VT ablation outcome data from our center. In 2021 and 2022, 68 VT ablations were performed in 60 patients with structural heart disease. After a median follow-up of 20 months, 18 percent had recurrent VT and there were 2 major adverse events (stroke and complete atrioventricular block). Seven patients died from non-arrhythmia related causes during follow-up. A large proportion (68 percent) were subacute procedures which are associated with a higher periprocedural risk. Referral for VT ablation earlier in the course of disease progression may likely further improve outcomes.


Subject(s)
Catheter Ablation , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Catheter Ablation/methods , Catheter Ablation/adverse effects , Tachycardia, Ventricular/surgery , Defibrillators, Implantable/adverse effects , Treatment Outcome , Recurrence , Male , Female , Aged , Sweden , Middle Aged , Postoperative Complications/etiology
11.
Europace ; 26(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38934242

ABSTRACT

AIMS: Wild-type transthyretin amyloid cardiomyopathy (ATTRwt-CM) is often accompanied by atrial fibrillation (AF), atrial flutter (AFL), and atrial tachycardia (AT), which are difficult to control because beta-blockers and antiarrhythmic drugs can worsen heart failure (HF). This study aimed to investigate the outcomes of catheter ablation (CA) for AF/AFL/AT in patients with ATTRwt-CM and propose a treatment strategy for CA. METHODS AND RESULTS: A cohort study was conducted on 233 patients diagnosed with ATTRwt-CM, including 54 who underwent CA for AF/AFL/AT. The background of each arrhythmia and the details of the CA and its outcomes were investigated. The recurrence-free rate of AF/AFL/AT overall in ATTRwt-CM patients with multiple CA was 70.1% at 1-year, 57.6% at 2-year, and 44.0% at 5-year follow-up, but CA significantly reduced all-cause mortality [hazard ratio (HR): 0.342, 95% confidence interval (CI): 0.133-0.876, P = 0.025], cardiovascular mortality (HR: 0.378, 95% CI: 0.146-0.981, P = 0.045), and HF hospitalization (HR: 0.488, 95% CI: 0.269-0.889, P = 0.019) compared with those without CA. There was no recurrence of the cavotricuspid isthmus (CTI)-dependent AFL, non-CTI-dependent simple AFL terminated by one linear ablation, and focal AT originating from the atrioventricular (AV) annulus or crista terminalis eventually. Twelve of 13 patients with paroxysmal AF and 27 of 29 patients with persistent AF did not have recurrence as AF. However, all three patients with non-CTI-dependent complex AFL not terminated by a single linear ablation and 10 of 13 cases with focal AT or multiple focal ATs originating beyond the AV annulus or crista terminalis recurred even after multiple CA. CONCLUSION: The outcomes of CA for ATTRwt-CM were acceptable, except for multiple focal AT and complex AFL. Catheter ablation may be aggressively considered as a treatment strategy with the expectation of improving mortality and hospitalization for HF.


Subject(s)
Amyloid Neuropathies, Familial , Atrial Fibrillation , Atrial Flutter , Cardiomyopathies , Catheter Ablation , Humans , Catheter Ablation/adverse effects , Male , Atrial Flutter/surgery , Atrial Flutter/etiology , Female , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Aged , Amyloid Neuropathies, Familial/surgery , Amyloid Neuropathies, Familial/complications , Amyloid Neuropathies, Familial/mortality , Cardiomyopathies/mortality , Cardiomyopathies/therapy , Treatment Outcome , Middle Aged , Recurrence , Tachycardia, Supraventricular/surgery , Tachycardia, Supraventricular/etiology , Tachycardia, Supraventricular/physiopathology , Tachycardia, Supraventricular/diagnosis , Retrospective Studies , Prealbumin/genetics , Prealbumin/metabolism
12.
BMC Cardiovasc Disord ; 24(1): 246, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38730404

ABSTRACT

BACKGROUND: Clinical outcomes after catheter ablation (CA) or pacemaker (PM) implantation for the tachycardia-bradycardia syndrome (TBS) has not been evaluated adequately. We tried to compare the efficacy and safety outcomes of CA and PM implantation as an initial treatment option for TBS in paroxysmal atrial fibrillation (AF) patients. METHODS: Sixty-eight patients with paroxysmal AF and TBS (mean 63.7 years, 63.2% male) were randomized, and received CA (n = 35) or PM (n = 33) as initial treatments. The primary outcomes were unexpected emergency room visits or hospitalizations attributed to cardiovascular causes. RESULTS: In the intention-to-treatment analysis, the rates of primary outcomes were not significantly different between the two groups at the 2-year follow-up (19.8% vs. 25.9%; hazard ratio (HR) 0.73, 95% confidence interval (CI) 0.25-2.20, P = 0.584), irrespective of whether the results were adjusted for age (HR 1.12, 95% CI 0.34-3.64, P = 0.852). The 2-year rate of recurrent AF was significantly lower in the CA group compared to the PM group (33.9% vs. 56.8%, P = 0.038). Four patients (11.4%) in the CA group finally received PMs after CA owing to recurrent syncope episodes. The rate of major or minor procedure related complications was not significantly different between the two groups. CONCLUSION: CA had a similar efficacy and safety profile with that of PM and a higher sinus rhythm maintenance rate. CA could be considered as a preferable initial treatment option over PM implantation in patients with paroxysmal AF and TBS. TRIAL REGISTRATION: KCT0000155.


Subject(s)
Atrial Fibrillation , Bradycardia , Cardiac Pacing, Artificial , Catheter Ablation , Heart Rate , Pacemaker, Artificial , Recurrence , Humans , Male , Female , Middle Aged , Catheter Ablation/adverse effects , Prospective Studies , Treatment Outcome , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Atrial Fibrillation/therapy , Atrial Fibrillation/surgery , Bradycardia/diagnosis , Bradycardia/therapy , Bradycardia/physiopathology , Cardiac Pacing, Artificial/adverse effects , Time Factors , Risk Factors , Syndrome , Tachycardia/physiopathology , Tachycardia/diagnosis , Tachycardia/therapy , Tachycardia/surgery
14.
Europace ; 26(7)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38801673

ABSTRACT

AIMS: Radiofrequency ablation is used as a first-line therapy for accessory pathways (APs). However, data regarding the effects of pulsed field ablation (PFA) on APs are limited. We sought to evaluate the acute procedural and 6-month success and safety of PFA in a cohort of patients with APs. METHODS AND RESULTS: A focal contact force-sensing PFA catheter was used for patients with APs. Pulsed field ablation generator generated a bipolar and biphasic waveform (±1000 V) with a duration of 100 ms from the tip of the PFA catheter. A 100% acute procedural success was achieved in 10 conscious patients with APs (7 left anterolateral, 2 left inferolateral, and 1 right posteroseptal APs) including 6 (60%) patients after an initial application. The average total ablation time was 6.3 ± 4.9 s for 4.7 ± 1.8 ablation sites (ASs), including 3.1 ± 2.4 s at targets and 3.2 ± 2.9 s at 3.2 ± 2 bolus ASs. The mean skin-to-skin time was 59.3 ± 15.5 min, and PFA catheter dwell time was 29.4 ± 7.8 min. One patient encountered transient sinus arrest during PFA due to parasympathetic overexcitation. Sinus rhythm was restored in all patients without any significant adverse events during the short-term follow-up. CONCLUSION: Pulsed field ablation of APs was feasible, effective, and safe. Its efficiency was remarkable for its ultrarapid termination of AP conduction. Further studies are warranted to prove whether utilization of PFA with current parameters can extend to manifold AP ablation.


Subject(s)
Accessory Atrioventricular Bundle , Catheter Ablation , Humans , Pilot Projects , Female , Male , Accessory Atrioventricular Bundle/surgery , Accessory Atrioventricular Bundle/physiopathology , Treatment Outcome , Adult , Catheter Ablation/methods , Catheter Ablation/adverse effects , Middle Aged , Young Adult , Time Factors , Heart Rate , Adolescent , Cardiac Catheters
15.
Circ Arrhythm Electrophysiol ; 17(6): e012523, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38690665

ABSTRACT

BACKGROUND: In the PARTITA trial (Does Timing of Ventricular Tachycardia Ablation Affect Prognosis in Patients With an Implantable Cardioverter Defibrillator?), antitachycardia pacing (ATP) predicted the occurrence of implantable cardioverter defibrillator (ICD) shocks. Catheter ablation of ventricular tachycardia after the first shock reduced the risk of death or worsening heart failure. A threshold of ATPs that might warrant an ablation procedure before ICD shocks is unknown. Our aim was to identify a threshold of ATPs and clinical features that predict the occurrence of shocks and cardiovascular events. METHODS: We analyzed data from 517 patients in phase A of the PARTITA study. We used classification and regression tree analysis to develop and test a risk stratification model based on arrhythmia patterns and clinical data to predict ICD shocks. Secondary end points were worsening heart failure and cardiovascular hospitalization. RESULTS: Classification and regression tree classified patients into 6 leaves by increasing shock probability. Patients treated with ≥5 ATPs in 6 months (active arrhythmia pattern) had the highest risk of ICD shocks (93% and 86%, training and testing samples, respectively). Patients without ATPs had the lowest (1% and 2%). Other predictors included left ventricle ejection fraction<35%, age of <60 years, and obesity. Survival analysis revealed a higher risk of worsening heart failure (hazard ratio, 5.45 [95% CI, 1.62-18.4]; P=0.006) and cardiovascular hospitalization (hazard ratio, 7.29 [95% CI, 3.66-14.5]; P<0.001) for patients with an active arrhythmia pattern compared with those without ATPs. CONCLUSIONS: Patients with an active arrhythmia pattern (≥5 ATPs in 6 months) are associated with an increased risk of ICD shocks, as well as heart failure hospitalization and cardiovascular hospitalization. These data suggest that additional treatments may be helpful to this high-risk group as a preventive strategy to reduce the incidence of major events. Further prospective randomized trials are needed to confirm the benefits of early ventricular tachycardia ablation in this setting.


Subject(s)
Defibrillators, Implantable , Electric Countershock , Heart Failure , Tachycardia, Ventricular , Humans , Female , Male , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/therapy , Tachycardia, Ventricular/mortality , Middle Aged , Aged , Risk Factors , Risk Assessment , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Heart Failure/physiopathology , Heart Failure/therapy , Heart Failure/diagnosis , Heart Failure/mortality , Catheter Ablation/adverse effects , Time Factors , Treatment Outcome , Cardiac Pacing, Artificial/adverse effects
16.
Circ Arrhythm Electrophysiol ; 17(6): e012635, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38804141

ABSTRACT

BACKGROUND: Irrigated radiofrequency ablation with half-normal saline can potentially increase lesion size but may increase the risk of steam pops with the risk of emboli or perforation. We hypothesized that pops would be preceded by intracardiac echocardiography (ICE) findings as well as a large impedance fall. METHODS: In 100 consecutive patients undergoing endocardial ventricular arrhythmia radiofrequency ablation with half-normal saline, we attempted to observe the ablation site with ICE. Radiofrequency ablation power was titrated to a 15 to 20 Ohm impedance fall and could be adjusted for tissue whitening and increasing bubble formation on ICE. Steam pops were defined as audible or a sudden explosion of microbubbles on ICE. RESULTS: Of 2190 ablation applications in 100 patients (82% cardiomyopathy, 50% sustained ventricular tachycardia), pops occurred during 43 (2.0%) applications. Sites with pops had greater impedance decreases of 18 [14, 21]% versus 13 [10, 17]% (P<0.001). ICE visualized 1308 (59.7%) radiofrequency sites, and fewer pops occurred when ICE visualized the radiofrequency ablation site (1.4%) compared with without ICE visualization (2.8%; P=0.016). Of the 18 ICE-visible pops, 7 (39%) were silent but recognized as an explosion of bubbles on ICE. With ICE, 89% of pops were preceded by either tissue whitening or a sudden increase in bubbles. In a multivariable model, tissue whitening and a sudden increase in bubbles were associated with steam pops (odds ratio, 7.186; P=0.004, and odds ratio, 29.93; P<0.001, respectively), independent of impedance fall and power. There were no pericardial effusions or embolic events with steam pops. CONCLUSIONS: Steam pops occurred in 2% of half-normal saline radiofrequency applications titrated to an impedance fall and are likely under-recognized without ICE. On ICE, steam pops are usually preceded by tissue whitening or a sudden increase in bubble formation, which can potentially be used to adjust radiofrequency application to help reduce pops.


Subject(s)
Catheter Ablation , Echocardiography , Saline Solution , Steam , Tachycardia, Ventricular , Therapeutic Irrigation , Humans , Male , Female , Saline Solution/administration & dosage , Middle Aged , Catheter Ablation/adverse effects , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/diagnostic imaging , Aged , Embolism, Air/prevention & control , Embolism, Air/etiology , Embolism, Air/diagnostic imaging , Treatment Outcome , Risk Factors , Predictive Value of Tests , Electric Impedance
17.
Clin Transl Gastroenterol ; 15(6): e00717, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38752627

ABSTRACT

INTRODUCTION: Gastroesophageal reflux disease (GERD) has been associated with increased incidence/recurrence of atrial fibrillation (AF). However, the impact of GERD and proton pump inhibitor (PPI) therapy on outcomes of AF catheter ablation remains unclear. We aimed to assess the association between the presence of GERD and risk of repeat AF ablation, stratified by PPI therapy. METHODS: A retrospective cohort study was conducted on patients with paroxysmal/persistent AF undergoing initial ablation in January 2011-September 2015. GERD was defined by endoscopic findings, objective reflux testing, or clinical symptoms. The association between GERD/PPI use and time to repeat ablation was evaluated by time-to-event analysis with censoring at the last clinic follow-up within 1 year. RESULTS: Three hundred eighty-one subjects were included. Patients with GERD (n = 80) had a higher 1-year repeat ablation rate compared with those with no GERD (25% vs 11.3%, P = 0.0034). Stratifying by PPI use, patients with untreated GERD (37.5%) more likely needed repeat ablation compared with reflux-free (11.3%, P = 0.0003) and treated GERD (16.7%, P = 0.035) subjects. On multivariable Cox regression analyses, GERD was an independent risk factor of repeat ablation (hazard ratio [HR] 3.30, confidence interval [CI] 1.79-6.08, P = 0.0001). Specifically, untreated GERD was associated with earlier repeat ablation compared with no GERD (HR 4.02, CI 1.62-12.05, P = 0.0013). However, no significant difference in repeat ablation risk was noted between reflux-free and PPI-treated GERD groups. DISCUSSION: GERD was an independent predictor for risk of repeat AF ablation within 1 year, even after controlling for major cardiovascular comorbidities and confounders. PPI therapy modulated this risk, as repeat ablation-free survival for PPI-treated GERD was noninferior to reflux-free patients.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Gastroesophageal Reflux , Proton Pump Inhibitors , Recurrence , Humans , Gastroesophageal Reflux/drug therapy , Gastroesophageal Reflux/surgery , Gastroesophageal Reflux/complications , Proton Pump Inhibitors/therapeutic use , Proton Pump Inhibitors/adverse effects , Atrial Fibrillation/surgery , Atrial Fibrillation/drug therapy , Male , Female , Retrospective Studies , Middle Aged , Catheter Ablation/adverse effects , Aged , Risk Factors , Reoperation/statistics & numerical data , Treatment Outcome
18.
Eur J Surg Oncol ; 50(7): 108366, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38692100

ABSTRACT

INTRODUCTION: Despite limited evidence, technique efficacy and complications may be important short-term outcomes after ablation for hepatocellular carcinoma (HCC). We aimed to report these outcomes after ablation as the first surgical intervention for HCC. METHODS: This nationwide cohort study was based on data from the Danish Liver and Biliary Duct Cancer Database and medical records. Variables associated with outcomes were investigated using logistic regression. RESULTS: From 2013 to 2023, 433 patients were included of which 79% were male, 73% had one tumor, and 90% had cirrhosis. Complete ablation was achieved after percutaneous, laparoscopic, and open approach in 84%, 100%, and 96% of the procedures, respectively. Most patients did not experience complications (76%). Open ablation compared with percutaneous was associated with higher risk of complications in multivariable adjusted analysis (Clavien-Dindo grade 2-5 (odds ratio 5.34, 95% confidence interval [2.36; 12.08]) and 3B-5 (5.70, [2.03; 16.01]), and lower risk of incomplete ablation (0.19 [0.05; 0.65]). Number of tumors ≥3 was associated with a higher risk of incomplete ablation (3.88, [1.45; 10.41]). Tumor diameter ≥3 cm was associated with increased risk of complications grade 2-5 (2.84, [1.29; 6.26]) and 3B-5 (4.44, [1.62; 12.13]). Performance status ≥2 was associated with risk of complications grade 3B-5 (5.98, [1.58; 22.69]). Tumor diameter was not associated with technique efficacy. CONCLUSION: Open ablation had a higher rate of complete ablation compared with percutaneous but was associated with a higher risk of complications. Tumor diameter ≥3 cm and performance status ≥2 were associated with a higher risk of complications.


Subject(s)
Carcinoma, Hepatocellular , Liver Neoplasms , Postoperative Complications , Humans , Carcinoma, Hepatocellular/surgery , Carcinoma, Hepatocellular/pathology , Male , Liver Neoplasms/surgery , Liver Neoplasms/pathology , Female , Aged , Postoperative Complications/epidemiology , Denmark/epidemiology , Middle Aged , Databases, Factual , Catheter Ablation/methods , Catheter Ablation/adverse effects , Laparoscopy , Treatment Outcome
20.
BMC Cardiovasc Disord ; 24(1): 255, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38755595

ABSTRACT

BACKGROUND: Ventricular tachycardia (VT) is the primary cause of sudden cardiac death in patients with hypertrophic cardiomyopathy (HCM). However, the strategy for VT treatment in HCM patients remains unclear. This study is aimed to compare the effectiveness of catheter ablation versus antiarrhythmic drug (AAD) therapy for sustained VT in patients with HCM. METHODS: A total of 28 HCM patients with sustained VT at 4 different centers between December 2012 and December 2021 were enrolled. Twelve underwent catheter ablation (ablation group) and sixteen received AAD therapy (AAD group). The primary outcome was VT recurrence during follow-up. RESULTS: Baseline characteristics were comparable between two groups. After a mean follow-up of 31.4 ± 17.5 months, the primary outcome occurred in 35.7% of the ablation group and 90.6% of the AAD group (hazard ratio [HR], 0.29 [95%CI, 0.10-0.89]; P = 0.021). No differences in hospital admission due to cardiovascular cause (25.0% vs. 71.0%; P = 0.138) and cardiovascular cause-related mortality/heart transplantation (9.1% vs. 50.6%; P = 0.551) were observed. However, there was a significant reduction in the composite endpoint of VT recurrence, hospital admission due to cardiovascular cause, cardiovascular cause-related mortality, or heart transplantation in ablation group as compared to that of AAD group (42.9% vs. 93.7%; HR, 0.34 [95% CI, 0.12-0.95]; P = 0.029). CONCLUSIONS: In HCM patients with sustained VT, catheter ablation reduced the VT recurrence, and the composite endpoint of VT recurrence, hospital admission due to cardiovascular cause, cardiovascular cause-related mortality, or heart transplantation as compared to AAD.


Subject(s)
Anti-Arrhythmia Agents , Cardiomyopathy, Hypertrophic , Catheter Ablation , Recurrence , Tachycardia, Ventricular , Humans , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/mortality , Tachycardia, Ventricular/therapy , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/surgery , Anti-Arrhythmia Agents/therapeutic use , Anti-Arrhythmia Agents/adverse effects , Catheter Ablation/adverse effects , Catheter Ablation/mortality , Male , Female , Middle Aged , Cardiomyopathy, Hypertrophic/mortality , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/diagnosis , Cardiomyopathy, Hypertrophic/physiopathology , Cardiomyopathy, Hypertrophic/surgery , Cardiomyopathy, Hypertrophic/therapy , Treatment Outcome , Time Factors , Adult , Retrospective Studies , Risk Factors , Aged , Heart Rate , China
SELECTION OF CITATIONS
SEARCH DETAIL
...