Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Publication year range
2.
BMC Pregnancy Childbirth ; 17(1): 246, 2017 Jul 26.
Article in English | MEDLINE | ID: mdl-28747164

ABSTRACT

BACKGROUND: To investigate the utility of vaginal placental alpha microglobulin-1 (PAMG-1) protein as a predictor of preterm delivery within 7 days in pregnancies at risk of premature birth. METHODS: This prospective study was performed in women at risk of premature birth. The levels of vaginal PAMG-1 and foetal fibronectin (fFN) and the transvaginal cervical length measurement (CLM) were investigated and compared. RESULTS: Seventy-two pregnant women were included in this study. The sensitivities of PAMG-1, fFN and CLM were 73.3, 73.6%, and 52.9%, respectively, while the specificities of PAMG-1, fFN and CLM were 92.9%, 94.3%, and 90.9%, respectively. The positive predictive values of PAMG-1, fFN and CLM were 73.3%, 82.3%, and 64.2%, respectively, and the negative predictive values of PAMG-1, fFN and CLM were 92.9%, 90.9%, and 86.2%, respectively. CONCLUSION: The diagnostic accuracy of PAMG-1 is similar to that of fFN in terms of preterm labour detection within 7 days.


Subject(s)
Cervical Length Measurement/nursing , Cervix Uteri/metabolism , Fibronectins/analysis , Insulin-Like Growth Factor Binding Protein 1/analysis , Obstetric Labor, Premature/diagnosis , Biomarkers/analysis , Female , Humans , Obstetric Labor, Premature/metabolism , Pregnancy , Prenatal Care/methods , Prospective Studies , Risk Factors
3.
Rev. bras. enferm ; 65(5): 775-779, set.-out. 2012. ilus
Article in Portuguese | LILACS, BDENF - Nursing | ID: lil-662657

ABSTRACT

Estudo longitudinal e prospectivo que procurou quantificar a variabilidade intra e interobservadores da medida da altura uterina (AU) e verificar a contribuição de um curso capacitatório para enfermeiros e graduandos de Enfermagem no viés de aferição da medida. Foram selecionados dois participantes, que realizaram duas medidas em vinte gestantes antes e após o curso. Calculou-se a variabilidade intra e interobservadores, o coeficiente de correlação intraclasse, o erro técnico de medida absoluto e relativo e a fiabilidade da medida. O teste t pareado mostrou redução estatisticamente significante (p=0,0396) no viés de aferição. Conclui-se que a capacitação de enfermeiros e graduandos de Enfermagem na técnica de medição da AU reduz significativamente a variabilidade intraobservador e interobservadores.


A prospective, longitudinal study sought to quantify the intra and inter-observer variability of the uterine height (UH) measurement and verify the contribution of a training course for nurses and nursing students in measurement bias. We selected two participants who performed two measurements in 20 pregnant women before and after the course. We calculated the intra and inter-observer variability, the coefficient of intraclass correlation, the absolute and relative technical error of measurement and the measure reliability. The paired t test showed a statistically significant reduce (p = 0.0396) in the measurement bias. We conclude that the training of nurses and nursing students in the technical measurement of UH significantly reduces intra and inter-observer variability.


Estudio prospectivo, longitudinal tratado de cuantificar la variabilidad intra y inter-observador de medición de el altura uterina (AU) y verificar la contribución de un curso capacitación para enfermeras y estudiantes de enfermería en los sesgos de medición. Fueran seleccionados dos participantes que realizaron dos mediciones de cada 20 mujeres embarazadas antes y después del curso. Se calculó la variabilidad intra y inter-observador, el coeficiente de correlación intraclase, el error técnico de medición absoluta y relativa y la fiabilidad de la medida. El teste t de Student mostró reducción estadísticamente significativa (p=0,0396) en el sesgo. Se concluye que la formación de enfermeras y estudiantes de enfermería en la técnica de medición de la AU redujo significativamente la variabilidad intra y inter-observador.


Subject(s)
Female , Humans , Pregnancy , Cervical Length Measurement/nursing , Cervical Length Measurement/statistics & numerical data , Education, Nursing , Nurses , Observer Variation , Prospective Studies , Students, Nursing
4.
Rev Bras Enferm ; 65(5): 775-9, 2012.
Article in Portuguese | MEDLINE | ID: mdl-23338581

ABSTRACT

A prospective, longitudinal study sought to quantify the intra and inter-observer variability of the uterine height (UH) measurement and verify the contribution of a training course for nurses and nursing students in measurement bias. We selected two participants who performed two measurements in 20 pregnant women before and after the course. We calculated the intra and inter-observer variability, the coefficient of intraclass correlation, the absolute and relative technical error of measurement and the measure reliability. The paired t test showed a statistically significant reduce (p = 0.0396) in the measurement bias. We conclude that the training of nurses and nursing students in the technical measurement of UH significantly reduces intra and inter-observer variability.


Subject(s)
Cervical Length Measurement/nursing , Cervical Length Measurement/statistics & numerical data , Education, Nursing , Female , Humans , Nurses , Observer Variation , Pregnancy , Prospective Studies , Students, Nursing
SELECTION OF CITATIONS
SEARCH DETAIL
...