Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 10.132
Filter
1.
BMC Oral Health ; 24(1): 902, 2024 Aug 06.
Article in English | MEDLINE | ID: mdl-39107737

ABSTRACT

BACKGROUND: Long-term success of implant restoration depends on many factors one of them is the sufficient implant stability which is lowered in compromised bone density sites such as the maxilla as it is categorized as type III & IV bone, so searching for a new innovation and updates in implant material and features is very mandatory. So, the aim of this study was to compare between two implant materials (roxolid and traditional titanium) on the primary and secondary stability of implant retained maxillary overdenture. METHODS: Eighteen completely edentulous patients were selected. All patients received maxillary implant-retained overdentures and lower complete dentures; patients were divided equally into two groups according to the type of implant materials. Group A received a total number of 36 implants made of roxolid material and Group B received a total number of 36 implants made of traditional titanium alloys. Implant stability was assessed using ostell device, the primary implant stability was measured at the day of implant installation however, secondary implant stability was measured after six weeks of implant placement. Paired t-test was used to compare between primary and secondary stability in the same group and an independent t-test was used to compare between the two groups with a significant level < 0.05. RESULTS: Independent t-test revealed a significant difference between the two groups with p -value = 0.0141 regarding primary stability and p-value < 0.001 regarding secondary stability, as roxolid implant group was statistically higher stability than titanium group in both. Paired t- test showed a statistically significant difference in roxolid implant group with p-value = 0.0122 however, there was non-statistically significant difference in titanium group with p-value = 0.636. Mann Whitney test showed a significant difference between the two groups regarding amount of change in stability with p value = 0.191. roxolid implant group showed a higher amount of change in stability than the titanium implant group. CONCLUSION: Within the limitation of this study, it could be concluded that: Roxolid implants showed promising results regarding primary and secondary stability compared to conventional Titanium implants and can be a better alternative in implant retained maxillary overdentures. TRIAL REGISTRATION: Retrospectively NCT06334770 at 26-3-2024.


Subject(s)
Dental Prosthesis, Implant-Supported , Denture, Overlay , Maxilla , Titanium , Humans , Male , Female , Maxilla/surgery , Middle Aged , Dental Implants , Dental Alloys/chemistry , Aged , Zirconium , Denture Retention , Dental Materials/chemistry , Alloys
2.
Dent Mater ; 40(9): 1487-1496, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38969574

ABSTRACT

OBJECTIVE: Current standardized in vitro bending experiments for orthodontic archwires cannot capture friction conditions and load sequencing during multi-bracket treatment. This means that clinically relevant forces exerted by superelastic wires cannot be predicted. To address these limitations, this study explored a novel test protocol that estimates clinical load range. METHODS: The correction of a labially displaced maxillary incisor was simulated using an in vitro model with three lingual brackets. Deflection force levels derived from four different protocols were designed to explore the impact of friction and wire load history. These force levels were compared in nickel-titanium (NiTi) archwires with three commonly used diameters. The unloading path varied between protocols, with single or multiple sequences and different load orders and initial conditions. RESULTS: Deflection forces from the new protocol, employing multiple continuous load/unload cycles (CCincr), consistently exceeded those from the conventional protocol using a single continuous unloading path (CUdecr). Mean differences in plateau force ranged from 0.54 N (Ø 0.014" wire) to 1.19 N (Ø 0.016" wire). The CCinr protocol also provided average force range estimates of 0.47 N (Ø 0.012" wire), 0.89 N (Ø 0.014" wire), and 1.15 N (Ø 0.016" wire). SIGNIFICANCE: Clinical orientation towards CUdecr carries a high risk of excessive therapeutic forces because clinical loading situations caused by friction and load history are underestimated. Physiological tooth mobility using NiTi wires contributes decisively to the therapeutic load situation. Therefore, only short unloading sequences starting from the maximum deflection in the load history, as in CCincr, are clinically meaningful.


Subject(s)
Dental Stress Analysis , Elasticity , Materials Testing , Nickel , Orthodontic Wires , Titanium , Nickel/chemistry , Titanium/chemistry , In Vitro Techniques , Incisor , Humans , Orthodontic Appliance Design , Orthodontic Brackets , Dental Alloys/chemistry , Friction , Maxilla
3.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 42(4): 462-469, 2024 Aug 01.
Article in English, Chinese | MEDLINE | ID: mdl-39049633

ABSTRACT

OBJECTIVES: To address the quality problems caused by high porosity in the preparation of dental cobalt-chrome alloy prosthetics based on selective laser melting (SLM) technology, we investigated the influence mechanism of different forming process parameters on the microstructure and properties of the materials. Moreover, the range of forming process parameters that can effectively reduce defects was precisely defined. METHODS: The effects of laser power, scanning speed, and scanning distance on the pore properties, surface roughness, and hardness of dental cobalt-chrome alloy were investigated by adjusting the printing parameters in the process of SLM. Through metallographic analysis, image analysis, and molten pool simulation, the pore formation mechanism was revealed, and the relationship between the porosity and energy density of SLM dental cobalt-chrome alloy was elucidated. RESULTS: When the linear energy density was higher than 0.18 J/mm, the porosity defect easily appeared at the bottom of the molten pool. When the laser energy density was lower than 0.13 J/mm, defects occurred in the gap of the molten pool due to insufficient melting of powder. In particular, when the linear energy density exceeded the threshold of 0.30 J/mm or was below 0.12 J/mm, the porosity increased significantly to more than 1%. In addition, we observed a negative correlation between free surface roughness and energy density and an inverse relationship between macroscopic hardness and porosity. CONCLUSIONS: On the basis of the conditions of raw materials and molding equipment used in this study, the key process parameters of SLM of molding parts with porosity lower than 1% were successfully determined. Specifically, these key parameters included the line energy density, which ranged from 0.13 J/mm to 0.30 J/mm, and the scan spacing should be strictly controlled below 90 µm.


Subject(s)
Chromium Alloys , Hardness , Lasers , Surface Properties , Porosity , Materials Testing , Cobalt/chemistry , Dental Alloys
5.
Indian J Dent Res ; 35(1): 70-75, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38934753

ABSTRACT

INTRODUCTION: The application of direct current can have a significant impact on the rate of tooth movement and surrounding periodontal ligament collagen turnover. This study aims to provide insight into the optimal characteristics of applied current to achieve enhanced tissue response. METHOD: Eighteen male Wistar rats were divided into three groups (I, II, and III). Split mouth design was used, and each side was allocated into an experimental group or control group. Experimental sides of groups I, II, and III received 20, 10, and 15 µA of current (15 min, twice daily for 3 days). Both the experimental and control groups receive an orthodontic force via the NiTi closed coil spring. The amount of tooth movement was determined daily. Immunohistochemistry slides were scored using the immunoreactive scoring (IRS) system for collagen types I and III. One-way Analysis of Variance (ANOVA) and Tukey post hoc test were used to analyse the rate of tooth movement, while Mann-Whitney test was used to analyse IRS distribution between control and experimental groups. RESULTS: Compared with the control group, there was a statistically significant difference in tooth movement in all the experimental groups, with group 3 showing the maximum rate on days 2 and 3. This was supported by immunoreactive scores for both collagen types I and III. CONCLUSIONS: After 72 hours, the expression of collagen types 1 and 3 increased significantly for group III. This finding was in harmony with the rate of tooth movement, which was maximum for group 3 (15 µA) as compared to other groups.


Subject(s)
Collagen Type III , Collagen Type I , Immunohistochemistry , Periodontal Ligament , Rats, Wistar , Tooth Movement Techniques , Animals , Tooth Movement Techniques/methods , Male , Rats , Collagen Type I/analysis , Collagen Type III/analysis , Orthodontic Wires , Dental Alloys/chemistry , Nickel , Stress, Mechanical , Titanium
6.
BMC Oral Health ; 24(1): 710, 2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38902669

ABSTRACT

BACKGROUND: Failure of orthodontic bracket bonds is a common occurrence during orthodontic treatment. This study investigated the impact of Er: YAG laser-based removal of adhesive from the bases of metal and ceramic brackets for re-bonding. METHODS: A total of 168 extracted premolars were collected from patients. 84 metal brackets were used to be bonded on the buccal surface of the premolars in Groups 1, 2, 3 and 4, while 84 ceramic brackets were applied in Groups I, II, III and IV. Group 1/I represented the initial bonding group, with Group 2/II being the re-bonding group with new brackets, while Groups 3/III and 4/ IV received recycled brackets treated by Er: YAG laser or flaming respectively. Both the first and second de-bonding were performed in all samples using a universal testing machine to determine the shear bond strength (SBS). The adhesive remnant index (ARI) was evaluated using a stereo-microscope. The new and the treated bracket bases were evaluated using scanning electron microscopy (SEM). Differences in initial bonding and re-bonding ability were analyzed through one-way ANOVAs, and differences in ARI were assessed with the Kruskal-Wallis test. RESULTS: Greater amounts of adhesive residue were observed on ceramic brackets treated by laser. The SBS values for recycled metal brackets in Group 3 (26.13 MPa) were comparable to Group 1 (23.62 MPa) whereas they differed significantly from Group 4 (12.54 MPa). No significant differences in these values were observed when comparing the 4 groups with ceramic brackets. ARI score in Group 4 (2-3 points) differed significantly from the three other groups (P < 0.05). For Group I, II, III and IV, similar ARI scores were observed (P > 0.05). SEM analysis didn't show apparent damage of bracket bases consisting of either metal or ceramic material treated by Er: YAG laser. CONCLUSIONS: Er: YAG laser treatment was superior to flame treatment as a means of removing adhesive without damaging the brackets. SBS values and ARI scores following Er: YAG laser treatment were similar to those for new brackets, offering further support for Er: YAG laser treatment as a viable means of recycling debonded brackets.


Subject(s)
Ceramics , Dental Bonding , Dental Debonding , Dental Stress Analysis , Lasers, Solid-State , Microscopy, Electron, Scanning , Orthodontic Brackets , Shear Strength , Lasers, Solid-State/therapeutic use , Humans , Dental Bonding/methods , Ceramics/chemistry , Dental Debonding/methods , Materials Testing , Surface Properties , Bicuspid , Dental Alloys/chemistry , Resin Cements/chemistry
7.
BMC Oral Health ; 24(1): 501, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38725023

ABSTRACT

BACKGROUND: Releasing of metal ions might implicate in allergic reaction as a negative subsequent of the corrosion of Stainless Steel (SS304) orthodontic wires. The aim of this study was to evaluate the corrosion resistance of zinc-coated (Zn-coated) SS orthodontic wires. METHODS: Zinc coating was applied on SS wires by PVD method. Electrochemical impedance spectroscopy (EIS), Potentiodynamic polarization tests and Tafel analysis methods were used to predict the corrosion behavior of Zn-coated and uncoated SS wires in both neutral and acidic environments. RESULTS: The values of Ecorr ,icorr and Rct ,which were the electrochemical corrosion characteristics, reported better corrosion behavior of Zn-coated SS wires against uncoated ones in both artificial saliva and fluoride-containing environments. Experimental results of the Tafel plot analyses were consistent with that of electrochemical impedance spectroscopy analyses for both biological solutions. CONCLUSION: Applying Zn coating on bare SS orthodontic wire by PVD method might increase the corrosion resistance of the underlying stainless-steel substrate.


Subject(s)
Dielectric Spectroscopy , Materials Testing , Orthodontic Wires , Saliva, Artificial , Stainless Steel , Zinc , Corrosion , Stainless Steel/chemistry , Zinc/chemistry , Saliva, Artificial/chemistry , Dental Alloys/chemistry , Coated Materials, Biocompatible/chemistry , Fluorides/chemistry , Hydrogen-Ion Concentration , Humans , Surface Properties , Potentiometry
8.
Dental Press J Orthod ; 29(2): e2423282, 2024.
Article in English | MEDLINE | ID: mdl-38775601

ABSTRACT

OBJECTIVE: This study aimed to compare the insertion torque (IT), flexural strength (FS) and surface alterations between stainless steel (SS-MIs) and titanium alloy (Ti-MIs) orthodontic mini-implants. METHODS: Twenty-four MIs (2 x 10 mm; SS-MIs, n = 12; Ti-MIs, n = 12) were inserted on artificial bone blocks of 20 lb/ft3 (20 PCF) and 40 lb/ft3 (40 PCF) density. The maximum IT was recorded using a digital torque meter. FS was evaluated at 2, 3 and 4 mm-deflection. Surface topography and chemical composition of MIs were assessed by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). General linear and mixed models were used to assess the effect of the MI type, bone density and deflection on the evaluated outcomes. RESULTS: The IT of Ti-MIs was 1.1 Ncm greater than that obtained for the SS-MIs (p= 0.018). The IT for MIs inserted in 40 PCF test blocks was 5.4 Ncm greater than that for those inserted in 20 PCF test blocks (p < 0.001). SS-MIs inserted in higher density bone (40 PCF) had significantly higher flexural strength than the other groups, at 2 mm (98.7 ± 5.1 Ncm), 3 mm (112.0 ± 3.9 Ncm) and 4 mm (120.0 ± 3.4 Ncm) of deflection (p< 0.001). SEM evidenced fractures in the Ti-MIs. EDS revealed incorporation of 18% of C and 2.06% of O in the loaded SS-MIs, and 3.91% of C in the loaded Ti-MIs. CONCLUSIONS: Based on the findings of this in vitro study, it seems that SS-MIs offer sufficient stability and exhibit greater mechanical strength, compared to Ti-MIs when inserted into higher density bone.


Subject(s)
Dental Alloys , Dental Implants , Flexural Strength , Materials Testing , Microscopy, Electron, Scanning , Orthodontic Anchorage Procedures , Stainless Steel , Surface Properties , Titanium , Torque , Titanium/chemistry , Stainless Steel/chemistry , Orthodontic Anchorage Procedures/instrumentation , Orthodontic Anchorage Procedures/methods , Dental Alloys/chemistry , In Vitro Techniques , Spectrometry, X-Ray Emission , Dental Stress Analysis , Humans , Stress, Mechanical , Bone Density
9.
Am J Orthod Dentofacial Orthop ; 166(2): 104-111, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38775764

ABSTRACT

INTRODUCTION: This 3-arm parallel, double-blind study aimed to evaluate the alignment efficiency of 3 different diameters of superelastic nickel-titanium (NiTi) archwires during the initial phase of orthodontic treatment. METHODS: Ninety-three patients with nonextraction treatment in the mandibular arch (using 0.022-in Roth prescription brackets) were randomly allocated into 3 groups: 0.012-in NiTi (group 1), 0.014-in NiTi (group 2), and 0.016-in NiTi (group 3). The alignment change was measured using the modified Little's irregularity index before archwire placement and every 4 weeks. The alignment efficiency of the 3 groups was analyzed. RESULTS: Ninety patients were analyzed (group 1: n = 29, group 2: n = 31, and group 3: n = 30; overall mean age, 16.6 years). The overall Wald test analysis revealed that wire type was not statistically significant (P = 0.91), whereas time exhibited significance as expected (P <0.001). Furthermore, the interaction between wire type and time was not significant (P = 0.93). The time-adjusted estimated difference between 0.014-in and 0.012-in was -0.49 (95% confidence interval, -2.83 to 1.85; P = 0.68). The time-adjusted estimated difference between 0.016-in and 0.012-in was -0.45 (95% confidence interval, -2.95 to 2.05; P = 0.72). No harm was observed. CONCLUSIONS: The clinical performance of 3 different sizes of NiTi archwires was similar. In addition, 0.014-in and 0.016-in NiTi archwires demonstrated better performances in aligning any irregularities because of a greater number of wire deformations in the 0.012-in group. REGISTRATION: IR.TBZMED.REC.1395.1039. PROTOCOL: The protocol was not published before trial commencement. FUNDING: None.


Subject(s)
Nickel , Orthodontic Wires , Titanium , Humans , Double-Blind Method , Female , Adolescent , Male , Orthodontic Appliance Design , Young Adult , Tooth Movement Techniques/instrumentation , Tooth Movement Techniques/methods , Dental Alloys/chemistry , Elasticity , Treatment Outcome , Child , Malocclusion/therapy
10.
BMC Oral Health ; 24(1): 564, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38745154

ABSTRACT

BACKGROUND: Alterations in the mechanical properties of the materials utilized in orthodontic appliances could affect the working properties of the appliances, thereby affecting clinical progress and outcome. Numerous studies have confirmed the correlation between alloy corrosion and raised surface roughness, which has a direct impact on the working characteristics of orthodontic archwires. METHODS: Thirty nickel-titanium (NiTi) orthodontic archwires were utilized in this study. Patients were randomly selected and allocated into three groups according to the randomization plan; (The control group): subjects practiced regular oral hygiene; (The fluoride group): subjects used fluoride for intensive prophylaxis; (The chlorhexidine group): subjects used chlorhexidine. Representative samples were evaluated by SEM, and then SEM images with high resolution were examined using Image J software to determine the surface roughness and obtain the results for further statistical analysis. RESULTS: Our findings indicated a significant difference was found between the three groups regarding the anterior and posterior parts between the control and the two other groups and a non-significant difference between NaF and CHX groups. Overall, the p-value for group comparisons was 0.000 for both parts, indicating a highly significant difference especially between the control and NaF groups. CONCLUSION: Mouthwashes containing sodium fluoride demonstrated more significant surface alterations than the control and CHX groups and should be prescribed in accordance with orthodontic materials to reduce side effects.


Subject(s)
Alloys , Chlorhexidine , Dental Alloys , Microscopy, Electron, Scanning , Nickel , Orthodontic Wires , Sodium Fluoride , Surface Properties , Humans , Sodium Fluoride/therapeutic use , Chlorhexidine/therapeutic use , Corrosion , Dental Alloys/chemistry , Nickel/chemistry , Titanium/chemistry , Cariostatic Agents/therapeutic use , Cariostatic Agents/chemistry , Male , Female , Young Adult , Mouthwashes/therapeutic use , Mouthwashes/chemistry , Image Processing, Computer-Assisted/methods , Adolescent , Adult , Oral Hygiene
11.
Clin Exp Dent Res ; 10(3): e893, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38770579

ABSTRACT

OBJECTIVES: The present study reviews the current literature regarding the utilization of the extended finite element method (XFEM) in clinical and experimental endodontic studies and the suitability of XFEM in the assessment of cyclic fatigue in rotary endodontic nickel-titanium (NiTi) instruments. MATERIAL AND METHODS: An electronic literature search was conducted using the appropriate search terms, and the titles and abstracts were screened for relevance. The search yielded 13 hits after duplicates were removed, and four studies met the inclusion criteria for review. RESULTS: No studies to date have utilized XFEM to study cyclic fatigue or crack propagation in rotary endodontic NiTi instruments. Challenges such as modelling material inputs and fatigue criteria could explain the lack of utilization of XFEM in the analysis of mechanical behavior in NiTi instruments. CONCLUSIONS: The review showed that XFEM was seldom employed in endodontic literature. Recent work suggests potential promise in using XFEM for modelling NiTi structures.


Subject(s)
Endodontics , Finite Element Analysis , Nickel , Titanium , Humans , Dental Alloys/chemistry , Dental Instruments , Endodontics/instrumentation , Endodontics/methods , Materials Testing , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Stress, Mechanical
12.
J Endod ; 50(8): 1143-1150, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38762142

ABSTRACT

INTRODUCTION: Nickel-titanium rotary endodontic files have been commercially available for decades, but more recent innovations have introduced heat-treated and surface-treated files. This study investigated the corrosion properties of various nickel-titanium files in normal saline and sodium hypochlorite (NaOCl). METHODS: Ten different file brands of size 40 with a 0.04 taper were subjected to electrochemical testing in 0.9% NaCl (saline) and 5.25% NaOCl at room temperature. The Open Circuit Potential (OCP) was observed for 1 hour followed by a cyclic polarization test from -300 to 700 mV and back to -300 mV (vs OCP). Nonparametric ANOVA and a pairwise comparison (P < .05) were used for statistical analysis of the OCP at 1 hour and the corrosion current (Icorr) obtained via the cyclic polarization test. RESULTS: Significant differences (P < .05) were found between files with respect to OCP and Icorr in both solutions. Nine files exhibited significantly greater (P < .05) Icorrs in NaOCl than in saline. Conversely, pitting corrosion was observed in the saline solution but not NaOCl. Weak and/or moderate correlations existed between OCP and Icorr measures in the 2 solutions. CONCLUSION: Significant differences in electrochemical properties were observed among the 10 brands of files. Overall, there was not a clear trend between conventional, heat-treated, or surface-treated files among OCP or Icorr in either solution.


Subject(s)
Nickel , Root Canal Preparation , Titanium , Nickel/chemistry , Titanium/chemistry , Corrosion , Root Canal Preparation/instrumentation , Sodium Hypochlorite/chemistry , Dental Instruments , Materials Testing , Electrochemistry , Electrochemical Techniques , Dental Alloys/chemistry , Surface Properties
13.
Eur Arch Paediatr Dent ; 25(3): 417-425, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38662172

ABSTRACT

PURPOSE: To investigate the in vitro biocompatibility of human gingival fibroblasts with preformed paediatric crowns and resistance to acid exposure at levels that simulate the oral environment. METHODS: This laboratory study investigated primary HGFs viability, metabolic activity, cytotoxicity, and apoptotic events on preformed metal crown discs, composite resin-coated wells, and monolithic zirconia fragments at 24, 48, and 72 h using the ApoTox-Glo Triplex assay. The PPCs were also immersed in 0.1% lactic acid, 0.2% phosphoric acid, or 10% citric acid for 7 days at 37 °C to reproduce conditions associated with dietary intake or gastric reflux. Samples were then subject to inductively coupled plasma optical emission spectrometry to quantitate the release of ions. RESULTS: The viability of HGFs on stainless steel and CR significantly declined at 48 and 72 h, representing potential cytotoxicity (p < 0.05). Cytotoxicity of HGFs was also higher for stainless steel and ZR compared to control (p < 0.05). PMCs and ZR crowns gave minimal ion release. Meanwhile, significant quantities of metallic ions, including copper (Cu), iron (Fe), nickel (Ni), and zinc (Zn), were present in eluates from veneered-preformed metal crowns. CONCLUSION: As PPCs can be exposed to highly acidic environments for many years, thus the release of metallic ions from V-PMCs should form the further investigation in future studies.


Subject(s)
Biocompatible Materials , Crowns , Fibroblasts , Gingiva , Materials Testing , Stainless Steel , Zirconium , Humans , Fibroblasts/drug effects , Stainless Steel/chemistry , Stainless Steel/toxicity , Gingiva/drug effects , Gingiva/cytology , Composite Resins/toxicity , Composite Resins/chemistry , Cell Survival/drug effects , Child , Zinc , Citric Acid , In Vitro Techniques , Nickel , Copper , Phosphoric Acids , Lactic Acid , Chromium/toxicity , Dental Materials/toxicity , Dental Alloys/toxicity , Dental Alloys/chemistry , Acids , Iron
14.
J World Fed Orthod ; 13(4): 189-196, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38653656

ABSTRACT

Orthodontic uprighting or traction of an impacted mandibular second molar often necessitates invasive interventions. This report aims to illustrate the utilization of nickel-titanium wire segments inserted into small, simple tubes for uprighting mesially impacted mandibular second molars and also for scissor bite correction. The term "simple tube" refers to a tube without a bonding base attached to a tooth surface by covering it with flowable composite resin. Due to the absence of a bonding base, the simple tube is characterized by its diminutive size and minimal profile height, facilitating placement on partially exposed second molars and unconventional positioning to adjust the force geometry. In this case study, mesially-impacted mandibular second molars with scissor bite were uprighted in a 21-year-old male utilizing simple tubes. Simple tubes can be used for molar uprighting and scissor bite correction buccally and lingually.


Subject(s)
Mandible , Molar , Nickel , Orthodontic Wires , Tooth Movement Techniques , Tooth, Impacted , Humans , Male , Young Adult , Tooth Movement Techniques/instrumentation , Tooth Movement Techniques/methods , Tooth, Impacted/therapy , Orthodontic Appliance Design , Titanium , Dental Alloys , Composite Resins
15.
Dent Mater J ; 43(3): 329-337, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38583993

ABSTRACT

The aim of this study was to evaluate how preset torque settings influence the torque, vertical force, and root canal-centering ability of ProGlider and ProTaper NEXT nickel-titanium rotary instruments in canals with different curvature locations. Based on micro-computed tomography, mesial roots of human mandibular molars (25°-40° curvature) were allocated to the apical curvature (apical 1-5 mm) or the middle curvature (apical 5-9 mm) groups, and mandibular incisors (curvature <5°) to the straight canal group. Each group was subjected to automated instrumentation and torque/force measurement with the preset torque of 1, 2.5, or 5 N•cm. Canal-centering ratios were determined with micro-computed tomography. Instrument fracture occurred only in the 2.5 and 5 N•cm groups in curved canals. The preset torque setting and curvature location did not influence canal shaping ability.


Subject(s)
Nickel , Root Canal Preparation , Surface Properties , Titanium , Torque , X-Ray Microtomography , Humans , Titanium/chemistry , Nickel/chemistry , Root Canal Preparation/instrumentation , In Vitro Techniques , Dental Pulp Cavity , Molar , Dental Instruments , Materials Testing , Equipment Design , Dental Alloys/chemistry , Dental Stress Analysis
16.
J Endod ; 50(7): 1011-1016, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38642733

ABSTRACT

INTRODUCTION: The purpose of this study was to evaluate the effect of side flattening of cutting flutes on the cyclic resistance and torsional resistance of nickel-titanium files. METHODS: Both novel flattened Platinum V.EU (PL) and standard nonflattened CC Premium V.EU (CC) rotaries were tested. For cyclic fatigue tests, all the files were rotated in an artificial root canal with a curvature of 45° and a radius of 6.06 mm at 300 rpm (n = 15 in each group). The number of cycles to failure (NCF) was calculated. For torsional tests, the files were rotated at 2 rpm clockwise until fracture occurred. The maximum torque value at fracture was measured and the toughness and distortion angle were computed. Subsequently, 5 fragments were randomly selected in each experiment, the cross-section and longitudinal direction of the fragments were photographed using a scanning electron microscope. An unpaired t-test was performed at a significance level of 95%. RESULTS: There was a statistically significant difference in NCF between CC and PL (P < .05). CC showed higher NCF than PL. There was no statistically significant difference between CC and PL with regards to the parameters related to torsional resistance (distortion angle, ultimate strength, and toughness) (P > .05). CONCLUSION: Within the limitations of this study, side flattening of the file did not improve cyclic resistance or torsional resistance of the files. As side flattening may reduce a file's cyclic resistance, such files should be used with caution in clinical practice.


Subject(s)
Equipment Failure , Nickel , Root Canal Preparation , Titanium , Torsion, Mechanical , Root Canal Preparation/instrumentation , Materials Testing , Equipment Design , Torque , Microscopy, Electron, Scanning , Dental Instruments , Dental Alloys/chemistry
17.
Int J Oral Maxillofac Implants ; 39(2): 320, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38457263

ABSTRACT

PURPOSE: To investigate the biocompatibility of silver nanoparticle (AgNP)-doped Ti-6Al-4V surfaces by evaluating the viability and proliferation rate of human gingival fibroblasts (HGFs)-as the dominant cells of peri-implant soft tissues-seeded on the modified surfaces. MATERIALS AND METHODS: AgNPs (sizes 8 nm and 30 nm) were incorporated onto Ti-6Al-4V specimen surfaces via electrochemical deposition, using colloid silver dispersions with increasing AgNP concentrations of 100 ppm, 200 ppm, and 300 ppm. One control and six experimental groups were included in the study: (1) control (Ti-6Al-4V), (2) 8 nm/100 ppm, (3) 8 nm/200 ppm, (4) 8 nm/300 ppm, (5) 30 nm/100 ppm, (6) 30 nm/200 ppm, and (7) 30 nm/300 ppm. HGF cell primary cultures were isolated from periodontally healthy donor patients and cultured in direct contact with the group specimens for 24 and 72 hours. The cytotoxicity of AgNP-doped Ti-6Al-4V specimens toward HGF was assessed by the MTT (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide) and BrdU (5-bromo-2'-deoxyuridine) assay tests. Calcein AM and ethidium homodimer (EthD-1) fluorescent stains were used to determine the live and dead cells. The morphology and attachment properties of the HGFs were determined via scanning electron microscopy (SEM). RESULTS: Energy dispersive x-ray (EDX) analysis confirmed the presence of AgNPs on the specimens. The MTT test revealed that AgNPs of both sizes and all concentrations presented a decreased cellular metabolic activity compared to the control discs. All concentrations of both sizes of AgNPs affected the cell proliferation rate compared to the control group, as revealed by the BrdU assay. Overall, cytotoxicity of the modified Ti-6Al-4V surfaces depended on cell exposure time. Observation via confocal microscopy confirmed the results of the MTT and BrdU assay tests. Specifically, most cells remained alive throughout the 72-hour culture period. SEM images revealed that adjacent cells form bonds with each other, creating confluent layers of conjugated cells. CONCLUSIONS: The findings of the present study indicate that Ti-6Al-4V surfaces modified with 8 nm and 30 nm AgNPs at concentrations of 100 ppm, 200 ppm, and 300 ppm do not produce any serious cytotoxicity toward HGFs. The initial arrest of the HGF proliferation rate recovered at 72 hours. These results on the antibacterial activity against common periodontal pathogens, in combination with the results found in a previous study by the same research group, suggest that AgNP-doped Ti-6Al-4V surfaces are potential candidates for use in implant abutments for preventing peri-implant diseases.


Subject(s)
Alloys , Cell Proliferation , Cell Survival , Fibroblasts , Gingiva , Metal Nanoparticles , Silver , Surface Properties , Thiazoles , Titanium , Humans , Fibroblasts/drug effects , Titanium/toxicity , Titanium/chemistry , Gingiva/cytology , Gingiva/drug effects , Silver/chemistry , Silver/toxicity , Cell Proliferation/drug effects , Metal Nanoparticles/toxicity , Cell Survival/drug effects , Cells, Cultured , Alloys/toxicity , Materials Testing , Dental Alloys/chemistry , Dental Alloys/toxicity , Microscopy, Electron, Scanning , Coloring Agents , Biocompatible Materials/chemistry , Tetrazolium Salts
18.
Int Orthod ; 22(2): 100866, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38479220

ABSTRACT

INTRODUCTION: The aim of this study was to assess the interaction between a 0.019×0.025-inch (″) stainless steel archwire and two types of passive self-ligating brackets with the same slot height (0.022″) and different slot depths (0.028″ and 0.026″, and to measure the archwire/slot play as well as to compare the torque expression with archwire torsions of 12°, 24°, and 36°. MATERIAL AND METHODS: An experimental device was developed along with a universal testing machine to measure torque expression in two types of brackets with 0.028″ and 0.026″ slot depths. Analysis of variance (ANOVA) and Tukey's test were performed to identify the differences between groups. RESULTS: The 0.026″ slot bracket presented greater archwire/slot play when compared to the 0.028″ bracket. Torque expression with torsions of 24° and 36° were significantly higher in the 0.028″ depth brackets when compared to the 0.026″ depth brackets. CONCLUSION: The 0.022″×0.026″ passive self-ligating brackets attached with a 0.019″×0.025″ stainless steel archwire provided no greater torque control when compared to 0.022″×0.028″ passive self-ligating brackets.


Subject(s)
Dental Stress Analysis , Materials Testing , Orthodontic Appliance Design , Orthodontic Brackets , Orthodontic Wires , Stainless Steel , Torque , Humans , Dental Alloys/chemistry , In Vitro Techniques , Torsion, Mechanical
19.
J Dent ; 144: 104936, 2024 05.
Article in English | MEDLINE | ID: mdl-38492806

ABSTRACT

OBJECTIVE: To evaluate the three-dimensional (3D) stability and accuracy of additively manufactured surgical templates fabricated using two different 3D printers and materials. MATERIALS AND METHODS: Forty surgical templates were designed and printed using two different 3D printers: the resin group (n = 20) used a digital light processing (DLP) 3D printer with photopolymer resin, and the metal group (n = 20) employed a selective laser melting (SLM) 3D printer with titanium alloy. All surgical templates were scanned immediately after production and re-digitalized after one month of storage. Similarly, the implant simulations were performed twice. Three-dimensional congruency between the original design and the manufactured surgical templates was quantified using the root mean square (RMS), and the definitive and planned implant positions were determined and compared. RESULTS: At the postproduction stage, the metal templates exhibited higher accuracy than the resin templates (p < 0.001), and these differences persisted after one month of storage (p < 0.001). The resin templates demonstrated a significant decrease in three-dimensional stability after one month of storage (p < 0.001), whereas the metal templates were not affected (p > 0.05). No significant differences in implant accuracy were found between the two groups. However, the resin templates showed a significant increase in apical and angular deviations after one month of storage (p < 0.001), whereas the metal templates were not affected (p > 0.05). CONCLUSION: Printed metal templates showed higher fabrication accuracy than printed resin templates. The three-dimensional stability and implant accuracy of printed metal templates remained unaffected by one month of storage. CLINICAL SIGNIFICANCE: With superior three-dimensional stability and acceptable implant accuracy, printed metal templates can be considered a viable alternative technique for guided surgery.


Subject(s)
Printing, Three-Dimensional , Titanium , Humans , Titanium/chemistry , Computer-Aided Design , Lasers , Dental Implants , Alloys/chemistry , Imaging, Three-Dimensional/methods , Dental Implantation, Endosseous/instrumentation , Dental Implantation, Endosseous/methods , Dental Materials/chemistry , Dental Alloys/chemistry , Materials Testing
20.
Am J Orthod Dentofacial Orthop ; 165(5): 565-575, 2024 May.
Article in English | MEDLINE | ID: mdl-38372682

ABSTRACT

INTRODUCTION: This study aimed to investigate the surface free energy and surface roughness (SR) of metallic alloys under the influence of acid solutions. METHODS: The experiment involved the use of 270 rectangular wire samples measuring 0.019 × 0.025-in. These samples were sourced from 3 different commercial brands: Dentsply GAC, American Orthodontics, and Orthoclassic. This in vitro study categorized the samples into 3 groups based on the solutions employed: deionized water, citric acid, and phosphoric acid. Each group consisted of 90 samples, with 30 samples representing each type of alloy-stainless steel, nickel-titanium, and titanium molybdenum alloy (TMA). The wire segments were immersed in their respective solutions for 72 hours at a controlled temperature of 37°C, with continuous orbital agitation at 130 rpm. After the immersion period, the study analyzed both surface free energy and SR. The mean values obtained were subjected to an analysis of variance at a significance level of 5%. RESULTS: All alloys displayed hydrophobic behavior, as indicated by interaction free energy values <0. In acidic environments (phosphoric acid and citric acid), significant differences were observed among different brands and alloys, affecting surface energy and interaction free energy. Variations in SR among metallic alloys included steel with the lowest SR variations, followed by nickel-titanium and TMA. Notably, the TMA alloy stood out with significantly higher surface energy compared with that of the other alloys (P <0.001). CONCLUSIONS: In this study, all examined alloys demonstrated a hydrophobic nature, suggesting a limited attraction to water. Notably, TMA exhibited the least hydrophobic behavior among the alloys studied. However, when exposed to citric acid, TMA displayed the most substantial alterations in its surface properties. These results underscored the significance of accounting for the distinctive properties of each alloy and their responses to diverse challenges, such as exposure to acidic solutions, during the selection of orthodontic wires for orthodontics treatment.


Subject(s)
Alloys , Dental Alloys , Materials Testing , Orthodontic Wires , Surface Properties , Corrosion , Dental Alloys/chemistry , Nickel/chemistry , Titanium/chemistry , Citric Acid/chemistry , Stainless Steel/chemistry , Phosphoric Acids/chemistry , Molybdenum/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL