Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 19.213
Filter
1.
Physiother Res Int ; 29(4): e2127, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39234855

ABSTRACT

BACKGROUND AND PURPOSE: Diabetic polyneuropathy is a long-standing microvascular complication of diabetes that affects the postural control and functional mobility of patients. There are other microvascular complications, including pulmonary complications that reduce lung function. Multifactorial Inspiratory Muscle Training (IMT) can act as a home-based technique targeted to affect both these complications. This study aims to determine the effects of IMT on respiratory and functional parameters in diabetic polyneuropathy patients. METHODS: This is a Pre-Test Post-Test Randomized Controlled Trial (NCT#04947163) with 62 diabetic polyneuropathy patients. Each was randomly assigned to the IMT or sham-IMT group. Both the groups performed OTAGO exercises , with the sham-IMT group performing IMT at 15% of baseline maximal inspiratory pressure (MIP), whereas IMT were trained at 50% of baseline MIP as an initial intensity, which was increased as per the tolerance of patients. Both groups performed training for 12 weeks. The study investigated diaphragmatic strength, pulmonary function, functional capacity through 6MWT, 30s sit to stand test and anterior trunk muscle endurance tested through sit up test as outcome variables. Data was analysed on SPSS v26 at the significance level of 0.0.5. RESULTS: The IMT group significantly improved diaphragmatic strength, pulmonary function, 6MWT and anterior trunk muscle endurance when compared to the sham-IMT group. CONCLUSION: The study concluded that home-based IMT can improve pulmonary parameters including diaphragmatic strength and lung function as well as functional parameters including functional capacity in patients with diabetic polyneuropathy. The study was registered at ClinicalTrials.gov, NCT#04947163.


Subject(s)
Breathing Exercises , Diabetic Neuropathies , Muscle Strength , Respiratory Muscles , Humans , Male , Female , Diabetic Neuropathies/rehabilitation , Diabetic Neuropathies/physiopathology , Middle Aged , Muscle Strength/physiology , Respiratory Muscles/physiopathology , Respiratory Function Tests , Diaphragm/physiopathology , Aged , Adult
2.
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue ; 36(7): 740-744, 2024 Jul.
Article in Chinese | MEDLINE | ID: mdl-39223890

ABSTRACT

OBJECTIVE: To investigate the accuracy and reproducibility of diaphragmatic excursion (DE) measurements through hepato-renal/spleno-renal section as a novel method for assessing diaphragmatic function. METHODS: Twelve healthy participants were recruited. Each participant underwent DE measurements performed by four operators with varying levels of experience using traditional methods (liver/spleen section) and novel methods (hepato-renal/spleno-renal section), respectively. Among them, two experienced operators were critical care clinicians, and diaphragmatic ultrasound was performed in more than 50 cases. The other two inexperienced operators were respiratory therapists, with less than 10 cases of diaphragmatic ultrasound operations, who received a 2-hour theoretical and operational training before the study. Operators initially used the conventional method with a 1.5-6.0 MHz convex probe in M-mode, placing the sampling line perpendicular to the diaphragm at the point of maximum excursion, and the liver/spleen section DE was determined during normal breathing of participant. Then, they used the novel method with a 1.6-4.5 MHz phased array probe to observe diaphragmatic movement cranio-caudally along the mid-axillary line, employing anatomic M-mode with the sampling line placed perpendicular to the diaphragm at the level of the renal midpoint, and the DE of the hepato-renal/spleno-renal section was measured during normal breathing. The liver and hepato-renal sections were used to assess the right diaphragm, and spleen and spleno-renal sections were used to assess the left diaphragm. Correlation analysis of DE measurements from different sections was conducted using the Deming method, while consistency was assessed using the Bland-Altman method. The consistency of clinical acceptability was defined as the absence of fixed and proportional bias, with a difference of two standard deviations less than 40% of the mean measurement value. Percentage consistency limit = two standard deviations of the differences between measurements/mean measurement value×100%. RESULTS: Four operators performed image scans of DE in all four sections for each of the twelve subjects, with a high DE acquisition rate of 100% (48/48) for hepato-renal and spleno-renal sections, followed by the liver section [91.7% (44/48)] and the spleen section [66.7% (32/48)], particularly for the left diaphragm assessment, where the DE acquisition rate of spleno-renal section was significantly higher than that of traditional spleen section (P < 0.01). The overall measurement results showed that no significant difference was found in DE determined via the hepato-renal and spleno-renal sections using the novel method (cm: 1.64±0.10 vs. 1.55±0.14, P > 0.05), and they were significantly higher than those determined via the conventional liver and spleen sections (cm: hepato-renal section vs. liver section was 1.64±0.10 vs. 1.44±0.09, spleno-renal section vs. spleen section was 1.55±0.14 vs. 1.09±0.14, both P < 0.01). Correlation analysis revealed good correlations of DE between hepato-renal section and spleno-renal section, between liver section and hepato-renal section, between liver section and spleno-renal section (r values were 0.62, 0.59, and 0.42, all P < 0.01). Consistency analysis showed that the consistency in DE between hepato-renal section and spleno-renal section, as well as between liver section and hepato-renal section was good (both % consistency limits < 40%). However, the DE measured in the spleen section were not correlated with the other three sections, and there was no inconsistency (all % consistency limits > 40%). There was no statistically significant difference in DE measured by the four operators in the liver, spleen, hepato-renal, and spleno-renal sections (cm: 1.49±0.34, 1.44±0.37, 1.43±0.30, and 1.40±0.27 in liver section; 1.10±0.36, 1.05±0.18, 1.09±0.22, and 1.06±0.26 in spleen section; 1.67±0.43, 1.57±0.34, 1.63±0.32, and 1.66±0.36 in hepato-renal section; 1.45±0.33, 1.48±0.34, 1.50±0.24, and 1.65±0.26 in spleno-renal section; all P > 0.05). According to the clinically acceptable range of consistency limits, the DE measured by the four operators in all four sections showed good consistency (all % consistency limits < 40%). CONCLUSIONS: The novel method of measuring DE through hepato-renal/spleno-renal sections is accurate, highly reproducible, and has a high acquisition rate, serving as a viable alternative to the conventional method involving the liver/spleen section.


Subject(s)
Diaphragm , Spleen , Ultrasonography , Humans , Diaphragm/diagnostic imaging , Diaphragm/physiology , Adult , Male , Ultrasonography/methods , Female , Spleen/diagnostic imaging , Liver/diagnostic imaging , Young Adult , Kidney/diagnostic imaging , Reproducibility of Results
3.
J Transl Med ; 22(1): 732, 2024 Aug 05.
Article in English | MEDLINE | ID: mdl-39103816

ABSTRACT

BACKGROUND: Inspiratory muscle fatigue has been shown to have effects on limbs blood flow and physical performance. This study aimed to evaluate the influence of an inspiratory muscle fatigue protocol on respiratory muscle strength, vertical jump performance and muscle oxygen saturation in healthy youths. METHODS: A randomized and double-blinded controlled clinical trial, was conducted. Twenty-four participants aged 18-45 years, non-smokers and engaged in sports activity at least three times a week for a minimum of one year were enrolled in this investigation. Participants were randomly assigned to three groups: Inspiratory Muscle Fatigue (IMFG), Activation, and Control. Measurements of vertical jump, diaphragmatic ultrasound, muscle oxygen saturation, and maximum inspiratory pressure were taken at two stages: before the intervention (T1) and immediately after treatment (T2). RESULTS: The IMFG showed lower scores in muscle oxygen saturation and cardiorespiratory variables after undergoing the diaphragmatic fatigue intervention compared to the activation and control groups (p < 0.05). For the vertical jump variables, intragroup differences were found (p < 0.01), but no differences were shown between the three groups (p > 0.05). CONCLUSIONS: Inspiratory muscle fatigue appears to negatively impact vertical jump performance, muscle oxygen saturation and inspiratory muscle strength in healthy youths. TRIAL REGISTRATION: ClinicalTrials.gov ID: NCT06271876. Date of registration 02/21/2024. https://clinicaltrials.gov/study/NCT06271876 .


Subject(s)
Inhalation , Muscle Fatigue , Muscle Strength , Respiratory Muscles , Humans , Respiratory Muscles/physiology , Muscle Fatigue/physiology , Muscle Strength/physiology , Male , Adolescent , Young Adult , Female , Adult , Inhalation/physiology , Oxygen Saturation/physiology , Middle Aged , Diaphragm/physiology , Double-Blind Method
4.
Trials ; 25(1): 519, 2024 Aug 02.
Article in English | MEDLINE | ID: mdl-39095923

ABSTRACT

BACKGROUND: In the United States in 2017, there were an estimated 903,745 hospitalizations involving mechanical ventilation (MV). Complications from ventilation can result in longer hospital stays, increased risk of disability, and increased healthcare costs. It has been hypothesized that electrically pacing the diaphragm by phrenic nerve stimulation during mechanical ventilation may minimize or reverse diaphragm dysfunction, resulting in faster weaning. METHODS: The ReInvigorate Trial is a prospective, multicenter, randomized, controlled clinical trial evaluating the safety and efficacy of Stimdia's pdSTIM System for facilitating weaning from MV. The pdSTIM system employs percutaneously placed multipolar electrodes to stimulate the cervical phrenic nerves and activate contraction of the diaphragm bilaterally. Patients who were on mechanical ventilation for at least 96 h and who failed at least one weaning attempt were considered for enrollment in the study. The primary efficacy endpoint was the time to successful liberation from mechanical ventilation (treatment vs. control). Secondary endpoints will include the rapid shallow breathing index and other physiological and system characteristics. Safety will be summarized for both primary and additional analyses. All endpoints will be evaluated at 30 days or at the time of removal of mechanical ventilation, whichever is first. DISCUSSION: This pivotal study is being conducted under an investigational device exception with the U.S. Food and Drug Administration. The technology being studied could provide a first-of-kind therapy for difficult-to-wean patients on mechanical ventilation in an intensive care unit setting. TRIAL REGISTRATION: Clinicaltrials.gov, NCT05998018 , registered August 2023.


Subject(s)
Diaphragm , Multicenter Studies as Topic , Phrenic Nerve , Randomized Controlled Trials as Topic , Ventilator Weaning , Humans , Ventilator Weaning/methods , Diaphragm/innervation , Phrenic Nerve/physiology , Prospective Studies , Time Factors , Treatment Outcome , Respiration, Artificial/adverse effects , Respiration, Artificial/methods , Electric Stimulation Therapy/methods , Electric Stimulation Therapy/adverse effects , Electric Stimulation Therapy/instrumentation
5.
Eur Radiol Exp ; 8(1): 87, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39090324

ABSTRACT

BACKGROUND: Severe chronic obstructive pulmonary disease (COPD) often results in hyperinflation and flattening of the diaphragm. An automated computed tomography (CT)-based tool for quantifying diaphragm configuration, a biomarker for COPD, was developed in-house and tested in a large cohort of COPD patients. METHODS: We used the LungQ platform to extract the lung-diaphragm intersection, as direct diaphragm segmentation is challenging. The tool computed the diaphragm index (surface area/projected surface area) as a measure of diaphragm configuration on inspiratory scans in a COPDGene subcohort. Visual inspection of 250 randomly selected segmentations served as a quality check. Associations between the diaphragm index, Global Initiative for Chronic Obstructive Lung Disease (GOLD) stages, forced expiratory volume in 1 s (FEV1) % predicted, and CT-derived emphysema scores were explored using analysis of variance and Pearson correlation. RESULTS: The tool yielded incomplete segmentation in 9.2% (2.4% major defect, 6.8% minor defect) of 250 randomly selected cases. In 8431 COPDGene subjects (4240 healthy; 4191 COPD), the diaphragm index was increasingly lower with higher GOLD stages (never-smoked 1.83 ± 0.16; GOLD-0 1.79 ± 0.18; GOLD-1 1.71 ± 0.15; GOLD-2: 1.67 ± 0.16; GOLD-3 1.58 ± 0.14; GOLD-4 1.54 ± 0.11) (p < 0.001). Associations were found between the diaphragm index and both FEV1% predicted (r = 0.44, p < 0.001) and emphysema score (r = -0.36, p < 0.001). CONCLUSION: We developed an automated tool to quantify the diaphragm configuration in chest CT. The diaphragm index was associated with COPD severity, FEV1%predicted, and emphysema score. RELEVANCE STATEMENT: Due to the hypothesized relationship between diaphragm dysfunction and diaphragm configuration in COPD patients, automatic quantification of diaphragm configuration may prove useful in evaluating treatment efficacy in terms of lung volume reduction. KEY POINTS: Severe COPD changes diaphragm configuration to a flattened state, impeding function. An automated tool quantified diaphragm configuration on chest-CT providing a diaphragm index. The diaphragm index was correlated to COPD severity and may aid treatment assessment.


Subject(s)
Diaphragm , Pulmonary Disease, Chronic Obstructive , Tomography, X-Ray Computed , Humans , Pulmonary Disease, Chronic Obstructive/diagnostic imaging , Pulmonary Disease, Chronic Obstructive/physiopathology , Diaphragm/diagnostic imaging , Diaphragm/physiopathology , Tomography, X-Ray Computed/methods , Male , Female , Middle Aged , Aged , Forced Expiratory Volume
6.
Phys Med ; 125: 104495, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39098107

ABSTRACT

BACKGROUND: Surface-guided imaging (SGI) is increasingly utilized to monitor patient motion during deep inspiration breath hold (DIBH) in radiotherapy. Understanding the association between surface and internal motion is crucial for effective monitoring. PURPOSE: To investigate the relation between motion detected by SGI using surface-guided radiotherapy (SGRT) and internal motion measured through diaphragm tracking on kV projections acquired with DIBH for online CBCT. METHODS: Both SGI and kV were simultaneously acquired for ten patients over a total of 200 breath holds (BH). Diaphragm tracking was performed using second-degree polynomial curve fitting on the derivative images for each kV projection and high-pass filtering at 1/30 Hz to remove rotational effects. The superior-inferior (SI) and anterior-posterior (AP) motions of SGI were then compared to kV tracking using various statistical measures. RESULTS: The correlation (individuals' median: -0.07 to 0.73) was a suboptimal metric for the BH data. The median and 95th percentile absolute differences between SGI-SI and kV were 0.73 mm and 3.46 mm, respectively, during DIBH. For SGI-AP, the corresponding values were 0.55 mm and 2.80 mm. For inter-BH measurements, the contingency table based on a 3 mm threshold indicated surface/diaphragm motion agreement for SGI-SI/kV and SGI-AP/kV was 61 % and 56 %, respectively. CONCLUSION: Both intra- and inter-BH measurements indicated a limited association between surface and diaphragm motion, with certain constraints noted due to kV tracking and DIBH data. These findings warrant further investigation into the association between surface and internal motion.


Subject(s)
Breath Holding , Diaphragm , Movement , Humans , Diaphragm/diagnostic imaging , Diaphragm/physiology , Cone-Beam Computed Tomography/methods , Inhalation , Radiotherapy, Image-Guided/methods , Male , Image Processing, Computer-Assisted/methods , Female , Middle Aged
7.
BMC Med Imaging ; 24(1): 217, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-39148010

ABSTRACT

BACKGROUND: The ratio (E/Ea) of mitral Doppler inflow velocity to annular tissue Doppler wave velocity by transthoracic echocardiography and diaphragmatic excursion (DE) by diaphragm ultrasound have been confirmed to predict extubation outcomes. However, few studies focused on the predicting value of E/Ea and DE at different positions during a spontaneous breathing trial (SBT), as well as the effects of △E/Ea and △DE (changes in E/Ea and DE during a SBT). METHODS: This study was a reanalysis of the data of 60 difficult-to-wean patients in a previous study published in 2017. All eligible participants were organized into respiratory failure (RF) group and extubation success (ES) group within 48 h after extubation, or re-intubation (RI) group and non-intubation (NI) group within 1 week after extubation. The risk factors for respiratory failure and re-intubation including E/Ea and △E/Ea, DE and △DE at different positions were analyzed by multivariate logistic regression, respectively. The receiver operating characteristic (ROC) curves of E/Ea (septal, lateral, average) and DE (right, left, average) were compared with each other, respectively. RESULTS: Of the 60 patients, 29 cases developed respiratory failure within 48 h, and 14 of those cases required re-intubation within 1 week. Multivariate logistic regression showed that E/Ea were all associated with respiratory failure, while only DE (right) and DE (average) after SBT were related to re-intubation. There were no statistic differences among the ROC curves of E/Ea at different positions, nor between the ROC curves of DE. No statistical differences were shown in △E/Ea between RF and ES groups, while △DE (average) was remarkably higher in NI group than that in RI group. However, multivariate logistic regression analysis showed that △DE (average) was not associated with re-intubation. CONCLUSIONS: E/Ea at different positions during a SBT could predict postextubation respiratory failure with no statistical differences among them. Likewise, only DE (right) and DE (average) after SBT might predict re-intubation with no statistical differences between each other.


Subject(s)
Airway Extubation , Diaphragm , Respiratory Insufficiency , Ventilator Weaning , Humans , Male , Diaphragm/diagnostic imaging , Diaphragm/physiopathology , Female , Retrospective Studies , Respiratory Insufficiency/diagnostic imaging , Respiratory Insufficiency/physiopathology , Aged , Ventilator Weaning/methods , Middle Aged , ROC Curve , Echocardiography/methods , Heart/diagnostic imaging , Risk Factors
8.
Crit Care ; 28(1): 269, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39217380

ABSTRACT

This review explores the complex interactions between sedation and invasive ventilation and examines the potential of volatile anesthetics for lung- and diaphragm-protective sedation. In the early stages of invasive ventilation, many critically ill patients experience insufficient respiratory drive and effort, leading to compromised diaphragm function. Compared with common intravenous agents, inhaled sedation with volatile anesthetics better preserves respiratory drive, potentially helping to maintain diaphragm function during prolonged periods of invasive ventilation. In turn, higher concentrations of volatile anesthetics reduce the size of spontaneously generated tidal volumes, potentially reducing lung stress and strain and with that the risk of self-inflicted lung injury. Taken together, inhaled sedation may allow titration of respiratory drive to maintain inspiratory efforts within lung- and diaphragm-protective ranges. Particularly in patients who are expected to require prolonged invasive ventilation, in whom the restoration of adequate but safe inspiratory effort is crucial for successful weaning, inhaled sedation represents an attractive option for lung- and diaphragm-protective sedation. A technical limitation is ventilatory dead space introduced by volatile anesthetic reflectors, although this impact is minimal and comparable to ventilation with heat and moisture exchangers. Further studies are imperative for a comprehensive understanding of the specific effects of inhaled sedation on respiratory drive and effort and, ultimately, how this translates into patient-centered outcomes in critically ill patients.


Subject(s)
Anesthetics, Inhalation , Diaphragm , Respiration, Artificial , Humans , Diaphragm/drug effects , Anesthetics, Inhalation/administration & dosage , Anesthetics, Inhalation/pharmacology , Respiration, Artificial/methods , Lung/drug effects , Lung/physiology
9.
Int J Mol Sci ; 25(16)2024 Aug 17.
Article in English | MEDLINE | ID: mdl-39201644

ABSTRACT

Age-related impairment of the diaphragm causes respiratory complications. Neuromuscular junction (NMJ) dysfunction can be one of the triggering events in diaphragm weaknesses in old age. Prominent structural and functional alterations in diaphragm NMJs were described in elderly rodents, but NMJ changes in middle age remain unclear. Here, we compared diaphragm muscles from young adult (3 months) and middle-aged (12 months) BALB/c mice. Microelectrode recordings, immunofluorescent staining, electron microscopy, myography, and whole-body plethysmography were used. We revealed presynaptic (i) and postsynaptic (ii) changes. The former (i) included an increase in both action potential propagation velocity and neurotransmitter release evoked by low-, moderate-, and high-frequency activity but a decrease in immunoexpression of synapsin 1 and synaptic vesicle clustering. The latter (ii) consisted of a decrease in currents via nicotinic acetylcholine receptors and the area of their distribution. These NMJ changes correlated with increased contractile responses to moderate- to high-frequency nerve activation. Additionally, we found alterations in the pattern of respiration (an increase in peak inspiratory flow and a tendency of elevation of the tidal volume), which imply increased diaphragm activity in middle-aged mice. We conclude that enhancement of neuromuscular communication (due to presynaptic mechanism) accompanied by improved contractile responses occurs in the diaphragm in early aging.


Subject(s)
Aging , Diaphragm , Mice, Inbred BALB C , Neuromuscular Junction , Animals , Neuromuscular Junction/metabolism , Diaphragm/metabolism , Aging/metabolism , Aging/physiology , Mice , Receptors, Nicotinic/metabolism , Male , Synaptic Transmission/physiology , Action Potentials , Synaptic Vesicles/metabolism , Muscle Contraction/physiology , Synapsins/metabolism
10.
ACS Appl Mater Interfaces ; 16(33): 43199-43211, 2024 Aug 21.
Article in English | MEDLINE | ID: mdl-39120580

ABSTRACT

Spinal cord injury poses considerable challenges, particularly in diaphragm paralysis. To address limitations in existing diaphragm pacing technologies, we report an implantable, self-driven diaphragm pacing system based on a microvibration triboelectric nanogenerator (MV-TENG). Leveraging the efficient MV-TENG, the system harvests micromechanical energy and converts this energy into pulses for phrenic nerve stimulation. In vitro tests confirm a stable MV-TENG output, while subcutaneous implantation of the device in rats results in a constant amplitude over 4 weeks with remarkable energy-harvesting efficacy. The system effectively induces diaphragmatic motor-evoked potentials, triggering contractions of the diaphragm. This proof-of-concept system has potential clinical applications in implantable phrenic nerve stimulation, presenting a novel strategy for advancing next-generation diaphragm pacing devices.


Subject(s)
Diaphragm , Phrenic Nerve , Phrenic Nerve/physiology , Animals , Diaphragm/physiology , Diaphragm/innervation , Rats , Rats, Sprague-Dawley , Nanotechnology/instrumentation , Electric Stimulation Therapy/instrumentation , Male
11.
Respir Physiol Neurobiol ; 328: 104315, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39128767

ABSTRACT

Effects of sequential increase in airway resistance: no, low (5 kPa.s/l), high (24 kPa.s/l), and complete block in the inspiratory or expiratory phase of mechanically induced cough on the cough motor pattern were studied in 16 anesthetized (pentobarbital) spontaneously breathing cats (3.70±0.15 kg, 11♂, 5♀). Esophageal pressure and electromyographic activities of the diaphragm during inspiration and abdominal muscles during expiration were analyzed. No significant changes in the number of coughs occurred. Inspiratory occlusion caused a prolongation of cough inspiratory phase, cough inspiratory diaphragm activity, and all cough-related activity. Inspiratory occlusion along with high resistance increased inspiratory esophageal pressure amplitude, total cough cycle duration and the time between maximum activity of the diaphragm and abdominal muscles. High expiratory resistance and occlusion resulted in increased cough expiratory esophageal pressure amplitude, a longer active portion of cough expiration, and cough abdominal activity. Expiratory occlusion also prolonged cough expiratory phase, all cough activity, and total cough cycle. Significantly increased airway resistance and occlusion induce secondary, in addition to mechanical, changes in cough by significantly modulating the generated cough motor pattern. A certain level of resistance appears to be successfully compensated, resulting in minimal changes in coughing characteristics, including expiratory airflow and the rising time of the airflow. Afferent feedback from the respiratory tract, particularly volume feedback, represents a significant factor in modulating cough, mainly under various pathological conditions in the respiratory system.


Subject(s)
Airway Resistance , Cough , Electromyography , Respiratory Mechanics , Cough/physiopathology , Animals , Male , Cats , Female , Respiratory Mechanics/physiology , Airway Resistance/physiology , Abdominal Muscles/physiopathology , Abdominal Muscles/physiology , Diaphragm/physiopathology , Diaphragm/physiology , Esophagus/physiopathology , Esophagus/physiology
12.
BMC Neurol ; 24(1): 304, 2024 Aug 30.
Article in English | MEDLINE | ID: mdl-39215214

ABSTRACT

BACKGROUND: Diaphragmatic myoclonus is a rare motor disorder that affects muscle tone. It is characterized by involuntary movements of the abdominal wall and rhythmic, repetitive contractions of the accessory or respiratory muscles, all of which are innervated by the cervical nerve roots. CASE DESCRIPTION: We reviewed the case of a 57-year-old male patient who underwent surgery for a left cerebellar hemorrhage. He exhibited persistent myoclonus in the palate, jaw, and thoracoabdominal region. Following treatment, there was a significant reduction in flutter amplitude in these areas. CONCLUSION: The clinical rarity and variability of presentations often make diagnosis challenging and delayed. It is believed that this condition stems from abnormal excitation within the central nervous system or neural pathways that involve the phrenic nerve. Another potential mechanism is the direct irritation of the diaphragm. Ultrasound, chest fluoroscopy, and electromyography (EMG) can support the diagnosis. Various pharmacological and surgical treatments have been tried, yet specific treatment guidelines are still lacking.


Subject(s)
Diaphragm , Myoclonus , Humans , Male , Middle Aged , Myoclonus/etiology , Myoclonus/diagnosis , Myoclonus/physiopathology , Diaphragm/physiopathology , Diaphragm/diagnostic imaging , Diaphragm/innervation , Electromyography/methods , Cerebellar Diseases/diagnosis , Cerebellar Diseases/complications
13.
Respir Physiol Neurobiol ; 330: 104326, 2024 Dec.
Article in English | MEDLINE | ID: mdl-39209015

ABSTRACT

Codeine was microinjected into the area of the Kölliker-Fuse nucleus and the adjacent lateral parabrachial nucleus, within the pontine respiratory group in 8 anesthetized cats. Electromyograms (EMGs) of the diaphragm (DIA) and abdominal muscles (ABD), esophageal pressures (EP), and blood pressure were recorded and analyzed during mechanically induced tracheobronchial cough. Unilateral microinjections of 3.3 mM codeine (3 injections, each 37 ± 1.2 nl) had no significant effect on the cough number. However, the amplitudes of the cough ABD EMG, expiratory EP and, to a lesser extent, DIA EMG were significantly reduced. There were no significant changes in the temporal parameters of the cough. Control microinjections of artificial cerebrospinal fluid in 6 cats did not show a significant effect on cough data compared to those after codeine microinjections. Codeine-sensitive neurons in the rostral dorsolateral pons contribute to controlling cough motor output, likely through the central pattern generator of cough.


Subject(s)
Codeine , Cough , Electromyography , Animals , Cats , Cough/drug therapy , Cough/physiopathology , Codeine/pharmacology , Codeine/administration & dosage , Microinjections , Male , Pons/drug effects , Antitussive Agents/pharmacology , Antitussive Agents/administration & dosage , Female , Blood Pressure/drug effects , Blood Pressure/physiology , Kolliker-Fuse Nucleus/drug effects , Kolliker-Fuse Nucleus/physiology , Diaphragm/drug effects , Diaphragm/physiopathology , Parabrachial Nucleus/drug effects , Parabrachial Nucleus/physiology , Abdominal Muscles/drug effects
14.
Toxicology ; 507: 153890, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39029734

ABSTRACT

In the absence of appropriate medical care, exposure to organophosphorus nerve agents, such as VX, can lead to respiratory failure, and potentially death by asphyxiation. Despite the critical role of respiratory disturbances in organophosphorus-induced toxicity, the nature and underlying mechanisms of respiratory failure remain poorly understood. This study aimed to characterize respiratory alterations by determining their type and duration in mice exposed to a subcutaneous sublethal dose of VX. Respiratory ventilation in Swiss mice was monitored using dual-chamber plethysmography for up to 7 days post-exposure. Cholinesterase activity was assessed via spectrophotometry, and levels of inflammatory biomarkers were quantified using Luminex technology in blood and tissues involved in respiration (diaphragm, lung, and medulla oblongata). Additionally, a histological study was conducted on these tissues to ensure their structural integrity. Ventilatory alterations appeared 20-25 minutes after the injection of 0.9 LD50 VX and increased until the end of the recording, i.e., 40 minutes after intoxication. Concurrent with the occurrence of apnea, increased inspiratory and expiratory times resulted in a significant decrease in respiratory rate in exposed mice compared to controls. Ventilatory amplitude and, consequently, minute volume were reduced, while specific airway resistance significantly increased, indicating bronchoconstriction. These ventilatory effects persisted up to 24 or even 72 hours post-intoxication, resolving on the 7th day. They were correlated with a decrease in acetylcholinesterase activity in the diaphragm, which persisted for up to 72 hours, and with the triggering of an inflammatory reaction in the same tissue. No significant histologic lesions were observed in the examined tissues. The ventilatory alterations observed up to 72 hours post-VX exposure appear to result from a functional failure of the respiratory system rather than tissue damage. This comprehensive characterization contributes to a better understanding of the respiratory effects induced by VX exposure, which is crucial for developing specific medical countermeasures.


Subject(s)
Chemical Warfare Agents , Organothiophosphorus Compounds , Animals , Chemical Warfare Agents/toxicity , Mice , Male , Organothiophosphorus Compounds/toxicity , Acetylcholinesterase/metabolism , Lung/drug effects , Lung/pathology , Diaphragm/drug effects
15.
Transpl Int ; 37: 12897, 2024.
Article in English | MEDLINE | ID: mdl-38979122

ABSTRACT

Mutual interactions between the diaphragm and lung transplantation (LTx) are known to exist. Before LTx, many factors can exert notable impact on the diaphragmatic function, such as the underlying respiratory disease, the comorbidities, and the chronic treatments of the patient. In the post-LTx setting, even the surgical procedure itself can cause a stressful trauma to the diaphragm, potentially leading to morphological and functional alterations. Conversely, the diaphragm can significantly influence various aspects of the LTx process, ranging from graft-to-chest cavity size matching to the long-term postoperative respiratory performance of the recipient. Despite this, there are still no standard criteria for evaluating, defining, and managing diaphragmatic dysfunction in the context of LTx to date. This deficiency hampers the accurate assessment of those factors which affect the diaphragm and its reciprocal influence on LTx outcomes. The objective of this narrative review is to delve into the complex role the diaphragm plays in the different stages of LTx and into the modifications of this muscle following surgery.


Subject(s)
Diaphragm , Lung Transplantation , Humans , Postoperative Complications/etiology
16.
Fitoterapia ; 177: 106127, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39019238

ABSTRACT

Melanin is a dark pigment from the group of phenolic or indole polymers with inherent biocompatibility and antioxidant capacity. In extremophilic lichen Lobaria pulmonaria, melanin is responsible for protective properties against hostile environments. Herein, the ability of melanin extracted from L. pulmonaria to counteract oxidative stress and related damages was studied in the mouse diaphragm, the main respiratory muscle. Initial in vitro experiments demonstrated ultraviolet (UV)-absorbing, antioxidant and metal chelating activities of melanin. This melanin can form nanoparticles and stabile colloidal system at concentration of 5 µg/ml. Pretreatment of the muscle with melanin (5 µg/ml) markedly reduced UV-induced increase in intracellular and extracellular reactive oxygen species (ROS) as well as antimycin A-mediated enhancement in mitochondrial ROS production accompanied by lipid peroxidation and membrane asymmetry loss. In addition, melanin attenuated suppression of neuromuscular transmission and alterations of contractile responses provoked by hydrogen peroxide. Thus, this study shed the light on the perspectives of the application of a lichen melanin as a protective component for treatment of skeletal muscle disorders, which are accompanied with an increased ROS production.


Subject(s)
Antioxidants , Lichens , Melanins , Oxidative Stress , Reactive Oxygen Species , Animals , Melanins/pharmacology , Oxidative Stress/drug effects , Mice , Reactive Oxygen Species/metabolism , Lichens/chemistry , Antioxidants/pharmacology , Antioxidants/isolation & purification , Diaphragm/drug effects , Male , Lipid Peroxidation/drug effects , Muscle, Skeletal/drug effects
17.
Sci Transl Med ; 16(758): eadg3894, 2024 Jul 31.
Article in English | MEDLINE | ID: mdl-39083588

ABSTRACT

Patients receiving mechanical ventilation in the intensive care unit (ICU) frequently develop contractile weakness of the diaphragm. Consequently, they may experience difficulty weaning from mechanical ventilation, which increases mortality and poses a high economic burden. Because of a lack of knowledge regarding the molecular changes in the diaphragm, no treatment is currently available to improve diaphragm contractility. We compared diaphragm biopsies from ventilated ICU patients (N = 54) to those of non-ICU patients undergoing thoracic surgery (N = 27). By integrating data from myofiber force measurements, x-ray diffraction experiments, and biochemical assays with clinical data, we found that in myofibers isolated from the diaphragm of ventilated ICU patients, myosin is trapped in an energy-sparing, super-relaxed state, which impairs the binding of myosin to actin during diaphragm contraction. Studies on quadriceps biopsies of ICU patients and on the diaphragm of previously healthy mechanically ventilated rats suggested that the super-relaxed myosins are specific to the diaphragm and not a result of critical illness. Exposing slow- and fast-twitch myofibers isolated from the diaphragm biopsies to small-molecule compounds activating troponin restored contractile force in vitro. These findings support the continued development of drugs that target sarcomere proteins to increase the calcium sensitivity of myofibers for the treatment of ICU-acquired diaphragm weakness.


Subject(s)
Diaphragm , Muscle Contraction , Myosins , Respiration, Artificial , Respiratory Muscles , Humans , Animals , Myosins/metabolism , Diaphragm/metabolism , Diaphragm/physiopathology , Respiratory Muscles/metabolism , Rats , Male , Intensive Care Units , Middle Aged , Female , Aged , Hibernation/physiology , Actins/metabolism
18.
J Visc Surg ; 161(4): 262-266, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38971628
19.
J Neurophysiol ; 132(3): 678-684, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39052237

ABSTRACT

The diaphragm muscle (DIAm) is the primary inspiratory muscle in mammals. In awake animals, considerable heterogeneity in the electromyographic (EMG) activity of the DIAm reflects varied ventilatory and nonventilatory behaviors. Experiments in awake animals are an essential component to understanding the neuromotor control of breathing, which has especially begun to be appreciated within the last decade. However, insofar as the intent is to study the control of breathing, it is paramount to identify DIAm EMG activity that in fact reflects breathing. Current strategies for doing so in a reproducible, reliable, and efficient fashion are lacking. In the present article, we evaluated DIAm EMG from awake animals using hierarchical clustering across four-dimensional feature space to classify eupneic breathing. Our model, which can be implemented with automated threshold of the clustering dendrogram, successfully identified eupneic breathing with high F1 score (0.92), specificity (0.70), and accuracy (0.88), suggesting that it is a robust and reliable tool for investigating the neural control of breathing.NEW & NOTEWORTHY The heterogeneity of diaphragm muscle (DIAm) activity in awake animals reflects real motor behavior diversity but makes assessments of eupneic breathing challenging. The present article uses an unsupervised machine learning model to identify eupneic breathing amidst a deluge of different DIAm electromyography (EMG) burst patterns in awake rats. This technique offers a scalable and reliable tool that improves efficiency of DIAm EMG analysis and minimizes potential sources of bias.


Subject(s)
Diaphragm , Electromyography , Machine Learning , Respiration , Animals , Diaphragm/physiology , Rats , Male , Rats, Sprague-Dawley
20.
J Ultrasound ; 27(3): 733-737, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39060717

ABSTRACT

BACKGROUND: Recent studies have highlighted the recognition of diaphragmatic dysfunction as a significant factor contributing to respiratory disturbances in severely ill COVID-19 patients. In the field of noninvasive respiratory support, high-flow nasal cannula (HFNC) has shown effectiveness in relieving diaphragm dysfunction. This study aims to investigate the diaphragmatic response to HFNC in patients with COVID-19 pneumonia by utilizing ultrasound. METHODS: This retrospective study was conducted in a medical-surgical intensive care unit (ICU) at a tertiary care center in Buenos Aires, Argentina (Sanatorio de Los Arcos) over a 16-month period (January 2021-June 2022). The study included patients admitted to the ICU with a diagnosis of COVID-19 pneumonia who were deemed suitable candidates for HFNC therapy by the attending physician. Diaphragm ultrasound was conducted, measuring diaphragmatic excursion (DE) both before and during the utilization of HFNC for these patients. RESULTS: A total of 10 patients were included in the study. A statistically significant decrease in respiratory rate was observed with the use of HFNC (p = 0.02), accompanied by a significant increase in DE (p = 0.04). CONCLUSION: HFNC leads to a reduction in respiratory rate and an increase in DE as observed by ultrasound in patients with COVID-19 pneumonia, indicating promising enhancements in respiratory mechanics. However, further research is required to validate these findings.


Subject(s)
COVID-19 , Cannula , Diaphragm , Ultrasonography , Humans , COVID-19/therapy , COVID-19/complications , COVID-19/diagnostic imaging , Diaphragm/diagnostic imaging , Diaphragm/physiopathology , Male , Female , Retrospective Studies , Middle Aged , Ultrasonography/methods , Aged , Proof of Concept Study , SARS-CoV-2 , Oxygen Inhalation Therapy/methods , Intensive Care Units , Noninvasive Ventilation/methods , Adult , Respiratory Rate
SELECTION OF CITATIONS
SEARCH DETAIL