Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 1.926
1.
Mikrochim Acta ; 191(6): 362, 2024 06 01.
Article En | MEDLINE | ID: mdl-38822867

Rapid and accurate in situ determination of dopamine is of great significance in the study of neurological diseases. In this work, poly (3,4-ethylenedioxythiophene): poly (styrenesulfonic acid) (PEDOT: PSS)/graphene oxide (GO) fibers were fabricated by an effective method based on microfluidic wet spinning technology. The composite microfibers with stratified and dense arrangement were continuously prepared by injecting PEDOT: PSS and GO dispersion solutions into a microfluidic chip. PEDOT: PSS/GO fiber microelectrodes with high electrochemical activity and enhanced electrochemical oxidation activity of dopamine were constructed by controlling the structure composition of the microfibers with varying flow rate. The fabricated fiber microelectrode had a low detection limit (4.56 nM) and wide detection range (0.01-8.0 µM) for dopamine detection with excellent stability, repeatability, and reproducibility. In addition, the PEDOT: PSS/GO fiber microelectrode prepared was successfully used for the detection of dopamine in human serum and PC12 cells. The strategy for the fabrication of multi-component fiber microelectrodes is a new and effective approach for monitoring the intercellular neurotransmitter dopamine and has high potential as an implantable neural microelectrode.


Dopamine , Graphite , Microelectrodes , Polystyrenes , PC12 Cells , Dopamine/blood , Humans , Rats , Animals , Polystyrenes/chemistry , Graphite/chemistry , Limit of Detection , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Bridged Bicyclo Compounds, Heterocyclic/chemistry , Thiophenes/chemistry , Lab-On-A-Chip Devices , Polymers
2.
Mikrochim Acta ; 191(7): 365, 2024 06 04.
Article En | MEDLINE | ID: mdl-38831060

Copper-cobalt bimetallic nitrogen-doped carbon-based nanoenzymatic materials (CuCo@NC) were synthesized using a one-step pyrolysis process. A three-channel colorimetric sensor array was constructed for the detection of seven antioxidants, including cysteine (Cys), uric acid (UA), tea polyphenols (TP), lysine (Lys), ascorbic acid (AA), glutathione (GSH), and dopamine (DA). CuCo@NC with peroxidase activity was used to catalyze the oxidation of TMB by H2O2 at three different ratios of metal sites. The ability of various antioxidants to reduce the oxidation products of TMB (ox TMB) varied, leading to distinct absorbance changes. Linear discriminant analysis (LDA) results showed that the sensor array was capable of detecting seven antioxidants in buffer and serum samples. It could successfully discriminate antioxidants with a minimum concentration of 10 nM. Thus, multifunctional sensor arrays based on CuCo@NC bimetallic nanoenzymes not only offer a promising strategy for identifying various antioxidants but also expand their applications in medical diagnostics and environmental analysis of food.


Antioxidants , Carbon , Colorimetry , Copper , Nitrogen , Nitrogen/chemistry , Colorimetry/methods , Carbon/chemistry , Antioxidants/chemistry , Antioxidants/analysis , Copper/chemistry , Cobalt/chemistry , Hydrogen Peroxide/chemistry , Humans , Catalysis , Limit of Detection , Glutathione/chemistry , Glutathione/blood , Dopamine/blood , Dopamine/analysis , Dopamine/chemistry , Benzidines/chemistry , Polyphenols/chemistry , Polyphenols/analysis , Ascorbic Acid/chemistry , Ascorbic Acid/blood , Ascorbic Acid/analysis , Oxidation-Reduction , Uric Acid/blood , Uric Acid/chemistry , Uric Acid/analysis , Cysteine/chemistry , Cysteine/blood
3.
Molecules ; 29(9)2024 Apr 24.
Article En | MEDLINE | ID: mdl-38731427

Dopamine (DA) and uric acid (UA) are essential for many physiological processes in the human body. Abnormal levels of DA and UA can lead to multiple diseases, such as Parkinson's disease and gout. In this work, a three-dimensional reduced graphene oxide-MXene (3D rGO-Ti3C2) composite electrode was prepared using a simple one-step hydrothermal reduction process, which could separate the oxidation potentials of DA and UA, enabling the simultaneous detection of DA and UA. The 3D rGO-Ti3C2 electrode exhibited excellent electrocatalytic activity towards both DA and UA. In 0.01 M PBS solution, the linear range of DA was 0.5-500 µM with a sensitivity of 0.74 µA·µM-1·cm-2 and a detection limit of 0.056 µM (S/N = 3), while the linear range of UA was 0.5-60 µM and 80-450 µM, with sensitivity of 2.96 and 0.81 µA·µM-1·cm-2, respectively, and a detection limit of 0.086 µM (S/N = 3). In 10% fetal bovine serum (FBS) solution, the linear range of DA was 0.5-500 µM with a sensitivity of 0.41 µA·µM-1·cm-2 and a detection limit of 0.091 µM (S/N = 3). The linear range of UA was 2-500 µM with a sensitivity of 0.11 µA·µM-1·cm-2 and a detection limit of 0.6 µM (S/N = 3). The modified electrode exhibited advantages such as high sensitivity, a strong anti-interference capability, and good repeatability. Furthermore, the modified electrode was successfully used for DA measurement in vivo. This could present a simple reliable route for neurotransmitter detection in neuroscience.


Dopamine , Electrochemical Techniques , Electrodes , Graphite , Uric Acid , Graphite/chemistry , Uric Acid/analysis , Uric Acid/blood , Dopamine/analysis , Dopamine/blood , Electrochemical Techniques/methods , Limit of Detection , Oxidation-Reduction , Humans , Titanium/chemistry , Animals
4.
Rev Int Androl ; 22(1): 8-16, 2024 Mar.
Article En | MEDLINE | ID: mdl-38735872

Dopamine and prolactin are the key mediators involved in sexual function in both males and females, but the role of dopamine in female sexual dysfunction (FSD) is still unclear. The aim was to investigate the possible role of dopamine and their relationship with sex steroid hormones (estrogen, progesterone and dehydroepiandrosterone; DHEA) and prolactin levels in Egyptian women suffering from sexual dysfunction. This study included 84 women having sexual dysfunction (FSD group) and 84 normal sexual function (control group). All women were subjected to the questionnaire to assess their demographic and gynecological data as well as female sexual function index (FSFI). Blood samples were collected from all women for measuring serum estradiol, progesterone, DHEA, prolactin and dopamine levels. FSD patients had significantly higher serum progesterone and DHEA and prolactin levels; while significantly lower dopamine and estradiol levels versus controls (p < 0.001). In all women, dopamine level appeared as a predictor of FSD at cut-off point ≤8.8 ng/mL with sensitivity (75%), specificity (92%) and accuracy (83%) (p < 0.001). The low levels of dopamine were associated with significantly higher prevalence in patients with low estradiol (p < 0.001) and high progesterone (p < 0.001), DHEA (p < 0.001) and prolactin (p = 0.004). Also, dopamine was significantly positive correlation with arousal score (r = 0.16, p = 0.04), and negative correlation with age (r = -0.31, p < 0.001), pain score (r = -0.19, p = 0.01), DHEA (r = -0.45, p < 0.001) and prolactin (r = -0.28, p < 0.001). Low serum dopamine level is a potential diagnostic biomarker in women's sexual dysfunction and their association with high prolactin and sex steroid hormones dysfunction.


Biomarkers , Dopamine , Progesterone , Prolactin , Sexual Dysfunction, Physiological , Humans , Female , Dopamine/blood , Biomarkers/blood , Adult , Sexual Dysfunction, Physiological/blood , Sexual Dysfunction, Physiological/diagnosis , Prolactin/blood , Progesterone/blood , Estradiol/blood , Case-Control Studies , Egypt , Sensitivity and Specificity , Surveys and Questionnaires , Young Adult , Middle Aged , Dehydroepiandrosterone/blood , Gonadal Steroid Hormones/blood
5.
ACS Sens ; 9(5): 2684-2694, 2024 May 24.
Article En | MEDLINE | ID: mdl-38693685

Semiconductor-based photoelectrochemical (PEC) test protocols offer a viable solution for developing efficient individual health monitoring by converting light and chemical energy into electrical signals. However, slow reaction kinetics and electron-hole complexation at the interface limit their practical application. Here, we reported a triple-engineered CdS nanohierarchical structures (CdS NHs) modification scheme including morphology, defective states, and heterogeneous structure to achieve precise monitoring of the neurotransmitter dopamine (DA) in plasma and noninvasive body fluids. By precisely manipulating the Cd-S precursor, we achieved precise control over ternary CdS NHs and obtained well-defined layered self-assembled CdS NHs through a surface carbon treatment. The integration of defect states and the thin carbon layer effectively established carrier directional transfer pathways, thereby enhancing interface reaction sites and improving the conversion efficiency. The CdS NHs microelectrode fabricated demonstrated a remarkable negative response toward DA, thereby enabling the development of a miniature self-powered PEC device for precise quantification in human saliva. Additionally, the utilization of density functional theory calculations elucidated the structural characteristics of DA and the defect state of CdS, thus establishing crucial theoretical groundwork for optimizing the polymerization process of DA. The present study offers a potential engineering approach for developing high energy conversion efficiency PEC semiconductors as well as proposing a novel concept for designing sensitive testing strategies.


Cadmium Compounds , Dopamine , Electrochemical Techniques , Nanostructures , Neurotransmitter Agents , Sulfides , Cadmium Compounds/chemistry , Electrochemical Techniques/methods , Dopamine/analysis , Dopamine/blood , Nanostructures/chemistry , Neurotransmitter Agents/analysis , Neurotransmitter Agents/blood , Humans , Sulfides/chemistry , Photochemical Processes , Saliva/chemistry , Density Functional Theory , Biosensing Techniques/methods , Semiconductors , Microelectrodes
6.
Langmuir ; 40(22): 11635-11641, 2024 Jun 04.
Article En | MEDLINE | ID: mdl-38775800

The presence of abnormal dopamine (DA) levels may cause serious neurological disorders, therefore, the quantitative analysis of DA and its related research are of great significance for ensuring health. Herein, the bovine serum albumin (BSA) template method has been proposed for the preparation of catalytically high-performance ruthenium dioxide/multiwalled carbon nanotube (RuO2/MWCNT) nanocomposites. The incorporation of MWCNTs has improved the active surface area and conductivity while effectively preventing the aggregation of RuO2 nanoparticles. The outstanding electrocatalytic performance of RuO2/MWCNTs has promoted the electro-oxidation of DA at neutral pH. The electrochemical sensing platform based on RuO2/MWCNTs has demonstrated a wide linear range (0.5 to 111.1 µM), low detection limit (0.167 µM), excellent selectivity, long-term stability, and good reproducibility for DA detection. The satisfactory recovery range of 94.7% to 103% exhibited by the proposed sensing podium in serum samples signifies its potential for analytical applications. The aforementioned results reveal that RuO2/MWCNT nanostructures hold promising aptitude in the electrochemical sensor to detect DA in real samples, further offering broad prospects in clinical and medical diagnosis.


Biosensing Techniques , Dopamine , Electrochemical Techniques , Nanotubes, Carbon , Ruthenium Compounds , Serum Albumin, Bovine , Nanotubes, Carbon/chemistry , Dopamine/blood , Dopamine/analysis , Dopamine/chemistry , Humans , Biosensing Techniques/methods , Serum Albumin, Bovine/chemistry , Electrochemical Techniques/methods , Ruthenium Compounds/chemistry , Animals , Cattle , Limit of Detection
7.
Talanta ; 276: 126247, 2024 Aug 15.
Article En | MEDLINE | ID: mdl-38759358

This work presents a significant investigation involving both electrochemical experiment and quantum chemical simulation approaches. The objective was to characterize the electrochemical detection of dopamine (DA). The detection was carried out using a modified carbon paste electrode (CPE) incorporating bentonite (Bent) and l-cysteine (CySH) (named as CySH/Bent/CPE). To understand and explain the oxidation mechanism of DA on the CySH/Bent modified electrode surface, the coupling of the two approaches were exploited. The CySH/Bent/CPE showed excellent electroactivity toward DA such as good sensibility, selectivity, stability, and regenerative ability. The developed sensor shows a dynamic linear range from 0.8 to 80 µM with a limit of detection and quantification of 0.5 µM and 1.5 µM, respectively. During the quantitative analysis of DA in presence of ascorbic acid (AA) and uric acid (UA) the electrochemical oxidation signals of AA, DA, and UA distinctly appear as three separate peaks. The potential differences between the peaks are 190 mv, 150 mv, and 340 mV for the AA-DA, DA-UA, and AA-UA oxidation pairs, respectively. These observations stem from square wave voltammetry (SWV) studies, along with the corresponding redox peak potential separations. The developed sensor is simple and accurate to monitor DA in human serum samples. On the other hand, CySH acts as an electrocatalyst on the CySH/Bent/CPE surface by increasing its active electron transfer sites, as suggested by the quantum chemical modeling with analytical results of Fukui. Furthermore, the voltammetric results obtained agree well with the theoretical calculations.


Bentonite , Carbon , Cysteine , Dopamine , Electrochemical Techniques , Electrodes , Dopamine/blood , Dopamine/analysis , Dopamine/chemistry , Cysteine/chemistry , Cysteine/analysis , Cysteine/blood , Carbon/chemistry , Bentonite/chemistry , Electrochemical Techniques/methods , Quantum Theory , Oxidation-Reduction , Limit of Detection , Humans , Uric Acid/blood , Uric Acid/chemistry , Uric Acid/analysis
8.
J Chromatogr A ; 1724: 464910, 2024 Jun 07.
Article En | MEDLINE | ID: mdl-38657316

A simplified approach for preparation of sandwich type molecularly imprinted polymers (PPDA-MIPs) is proposed for simultaneously identify Low-density lipoprotein (LDL) and dispose "bad cholesterol". Porous polydopamine nanosphere (PPDA) is applied as a matrix for immobilization of LDL, and the imprinted layer is formed by dopamine acting as a functional monomer. Since imprinted cavities exhibit shape memory effects in terms of recognizing selectivity, the PPDA-MIPs exhibit excellent selectivity toward LDL and a substantial binding capacity of 550.3 µg mg-1. Meanwhile, six adsorption/desorption cycles later, the adsorption efficiency of 83.09 % is still achieved, indicating the adequate stability and reusability of PPDA-MIPs. Additionally, over 80 % of cholesterol is recovered, indicating the completeness of "bad cholesterol" removal in LDL. Lastly, as demonstrated by gel electrophoresis, PPDA-MIPs performed satisfactory behavior for the removal of LDL from the goat serum sample.


Cholesterol , Indoles , Lipoproteins, LDL , Molecularly Imprinted Polymers , Polymers , Lipoproteins, LDL/blood , Lipoproteins, LDL/chemistry , Lipoproteins, LDL/isolation & purification , Adsorption , Polymers/chemistry , Cholesterol/blood , Cholesterol/chemistry , Indoles/chemistry , Animals , Molecularly Imprinted Polymers/chemistry , Dopamine/blood , Dopamine/chemistry , Dopamine/isolation & purification , Dopamine/analysis , Molecular Imprinting/methods , Goats , Nanospheres/chemistry
9.
Analyst ; 149(9): 2728-2737, 2024 Apr 29.
Article En | MEDLINE | ID: mdl-38525963

This work presents the synthesis and characterization of an innovative F,S-doped carbon dots/CuONPs hybrid nanostructure obtained by a direct mixture between F,S-doped carbon dots obtained electrochemically and copper nitrate alcoholic solution. The hybrid nanostructures synthesized were characterized by absorption spectroscopy in the Ultraviolet region (UV-vis), high-resolution transmission electron microscopy (HRTEM), X-ray photoelectron spectroscopy (XPS), and different electrochemical techniques. The fluoride and sulfur-doped carbon dots/CuONPs nanostructures were used to prepare a non-enzymatic biosensor on a printed carbon electrode, exhibiting excellent electrocatalytic activity for the simultaneous determination of NADH, dopamine, and uric acid in the presence of ascorbic acid with a detection limit of 20, 80, and 400 nmol L-1, respectively. The non-enzymatic biosensors were also used to determine NADH, dopamine, and uric acid in plasma, and they did not suffer significant interference from each other.


Biosensing Techniques , Carbon , Copper , Dopamine , Electrochemical Techniques , Limit of Detection , NAD , Uric Acid , Uric Acid/blood , Uric Acid/chemistry , Biosensing Techniques/methods , Dopamine/blood , Dopamine/analysis , Carbon/chemistry , NAD/chemistry , NAD/blood , Copper/chemistry , Electrochemical Techniques/methods , Humans , Sulfur/chemistry , Fluorides/chemistry , Quantum Dots/chemistry , Nanostructures/chemistry , Electrodes
10.
Probl Endokrinol (Mosk) ; 70(2): 11-22, 2023 Jun 06.
Article Ru | MEDLINE | ID: mdl-38796757

BACKGROUND: Knowledge of the physiological mechanisms of adaptation arising in response to changes in photoperiods is especially important for residents of the European North. In the literature, there is practically no information about photoperiodic dynamics of serum dopamine level, despite its significant role in the regulation of the body's activity. The mutual modulating effect of the dopaminergic and thyroid systems is known. AIM: To show the ratio of dopamine levels and the content of hormones, protines and autoantibodies of the thyroid system, taking into account photoperiod of the year, in practically healthy populations of the European North. MATERIALS AND METHODS: Healthy male population (20 men) of Arkhangelsk was examined in various photoperiods of the year (80 samples): an increase in the length of daylight hours (March), its maximum duration (June), a decrease (September), and a minimum duration (December). The inhabitants of the settlements and the nomadic aboriginal population (100 men) were examined during 2 photoperiods of the year - March and December. The serum levels of iodothyronines, TSH, TG, antibodies to TPO, antibodies to TG and plasma level of dopamine were determined using ELISA methods. RESULTS: Residents of Arkhangelsk in June compared to December have higher levels of dopamine (0.502 and 0.365 nmol/l, p=0.01), T3 (1.09 and 0.94 nmol/l, p=0.003), T4 (113.45 and 99.03 nmol/l, p=0.0002). In September, compared with June, a decrease in dopamine (0.235 nmol/l, p=0.0003), T3 (0.92 nmol/l, p=0.004) was recorded with an increase in T4/T3 ratio from 106.54 to 117.89 units (p=0.006). The nomadic aboriginal population in March compared with December showed a tendency to a higher content of dopamine (0.00 and 0.394 nmol/l, p=0.07) with the decrease in fT4 (15.20 and  13.90, p=0.015), fT4/fT3 ratio from 3.13 to 2.28 units (p=0.006). In December, 67% of nomadic population had undetectable dopamine values (0 nmol/l) and 22% - excess dopamine values, in March 27% - excess values. CONCLUSION: Unidirectional changes in dopamine and thyroid activity in men of the European North were shown with their decrease during periods of decrease and minimum daylight hours and an increase during periods of increase and maximum daylight hours.


Dopamine , Photoperiod , Thyroid Gland , Humans , Male , Dopamine/blood , Adult , Thyroid Gland/physiology , Thyroid Gland/metabolism , Seasons , Russia , Middle Aged
11.
Sci Rep ; 12(1): 2598, 2022 02 16.
Article En | MEDLINE | ID: mdl-35173220

This prospective study determined the effects of hypoglycemic stimulation on vascular endothelial function in non-diabetic patients using reactive hyperemia peripheral arterial tonometry (RH-PAT). The study included non-diabetic patients who were hospitalized for an insulin tolerance test (ITT) for the diagnosis of hypoadrenocorticism or hypopituitarism. Vascular endothelial function was assessed using the reactive hyperemia index (RHI) measured by the RH-PAT. We also measured the levels of anterior pituitary hormone, adrenaline, noradrenaline, and dopamine at the time of hypoglycemia. The primary endpoint was a change in the RHI at 120 min after insulin administration. The study included 27 patients. ITT was associated with significant increases in systolic blood pressure, pulse rate, and the blood levels of adrenocorticotropic hormone, cortisol, growth hormone, adrenaline, noradrenaline, and dopamine. RHI significantly decreased after ITT from 2.24 ± 0.51 to 1.71 ± 0.42. A significant inverse correlation was observed between the change in RHI and change in adrenaline (r = - 0.670, p = 0.012). We concluded that hypoglycemic stimulation altered vascular endothelial function, as measured by RH-PAT, even in patients free of glucose intolerance. The observed deterioration in vascular endothelial function correlated with increases in catecholamine levels during hypoglycemia.Trial registration: UMIN000033244.


Endothelium, Vascular/physiopathology , Hypoglycemia/physiopathology , Manometry/methods , Adult , Aged , Arteries , Dopamine/blood , Epinephrine/blood , Female , Glucose Intolerance , Glucose Tolerance Test , Humans , Hyperemia , Hypoglycemia/blood , Insulin Resistance , Male , Middle Aged , Norepinephrine/blood , Pituitary Hormones, Anterior/blood , Prospective Studies , Systole
12.
Medicine (Baltimore) ; 100(49): e27867, 2021 Dec 10.
Article En | MEDLINE | ID: mdl-34889236

ABSTRACT: This study analyzed the Val158Met polymorphisms of the catechol-O-methyltransferase (COMT) gene and serum concentrations of catecholaminergic neurotransmitters in attention deficit hyperactivity disorder (ADHD) children and adolescents.All the subjects (180 paired ADHD and non-ADHD children and adolescents) were genotyped for the Val158Met polymorphisms of the COMT gene, and determined by the difference of dopamine and noradrenalin from a 1:1 paired case-control study.The frequencies of methionine (A)/A, valine (G)/A, and G/G were 51.67%, 41.11%, and 7.22% in the case group, and 62.22%, 31.11%, and 6.67% in the control group. There was a significant difference in the distribution of all genotypes of the COMT gene between the 2 groups (odds ratio = 1.85, 95% confidence interval: 1.62-2.08; χ2 = 7.80, P < .05). The serum concentrations of dopamine and noradrenalin were 1.42 ±â€Š0.34 ng/mL and 177.70 ±â€Š37.92 pg/mL in the case group, and 1.94 ±â€Š0.42 ng/mL and 206.20 ±â€Š42.45 pg/mL in the control group. There were the significant differences in the levels of dopamine and noradrenalin between the 2 groups (dopamine: t = 4.30, P < .01; noradrenalin: t = 2.24, P < .05).Our study suggested that the Val158Met polymorphisms of the COMT gene and serum concentrations of catecholaminergic neurotransmitters were associated with ADHD children and adolescents.


Attention Deficit Disorder with Hyperactivity/genetics , Catechol O-Methyltransferase/genetics , Dopamine/blood , Neurotransmitter Agents/blood , Adolescent , Case-Control Studies , Child , China , Female , Genotype , Humans , Male
13.
Mikrochim Acta ; 189(1): 12, 2021 12 06.
Article En | MEDLINE | ID: mdl-34866160

Novel Fe3O4@C@MnO2 composites were successfully synthesized for the first time via an interfacial reaction between magnetic porous carbon and KMnO4, in which the magnetic porous carbon was derived from the pyrolysis of Fe-MIL-88A under N2 atmosphere. Interestingly, the obtained Fe3O4@C@MnO2 composites were found to have triple-enzyme mimetic activity including peroxidase-like, catalase-like, and oxidase-like activity. As a peroxidase mimic, Fe3O4@C@MnO2 composites could catalyze the oxidation of TMB into a blue oxidized product by H2O2. As a catalase mimic, Fe3O4@C@MnO2 could catalyze the decomposition of H2O2 to generate O2 and H2O. As an oxidase mimic, Fe3O4@C@MnO2 could catalyze the direct oxidation of TMB to produce a blue oxidized product without H2O2. Reactive oxygen species measurements revealed that the oxidase-like activity originated from 1O2 and O2-∙and little∙OH generated by the dissolved oxygen, which was catalyzed by the Fe3O4@C@MnO2 in the TMB oxidation reaction. The oxidase-like activity of Fe3O4@C@MnO2 was investigated in detail. Under the optimized conditions, a rapid, sensitive, visual colorimetric method for dopamine detection was developed based on the inhibitory effect of dopamine on the oxidase-like activity. The proposed method allows for dopamine detection with a limit of detection of 0.034 µM and a linear range of 0.125-10 µM. This new colorimetric method was successfully used for the determination of dopamine in human blood samples.


Biosensing Techniques/methods , Carbon/chemistry , Dopamine/blood , Magnetite Nanoparticles/chemistry , Manganese Compounds/chemistry , Oxides/chemistry , Benzidines/chemistry , Benzothiazoles/chemistry , Catalysis , Chromogenic Compounds/chemistry , Colorimetry/methods , Dopamine/chemistry , Humans , Hydrogen Peroxide/chemistry , Limit of Detection , Metal-Organic Frameworks/chemistry , Oxidation-Reduction , Phenylenediamines/chemistry , Sulfonic Acids/chemistry
14.
Bull Exp Biol Med ; 171(6): 704-706, 2021 Oct.
Article En | MEDLINE | ID: mdl-34705169

Comparative analysis of blood sera from women with alcohol dependence and depressive disorders or from conditionally healthy women revealed reduced level of antibodies to dopamine, norepinephrine, serotonin, glutamate, and GABA in blood serum in women with dysthymic disorder and a depressive episode and their increased content in women with alcohol dependence in combination with depressive disorders.


Alcoholism/immunology , Autoantibodies/blood , Depressive Disorder/immunology , Dysthymic Disorder/immunology , Alcoholism/blood , Alcoholism/complications , Alcoholism/physiopathology , Case-Control Studies , Depressive Disorder/blood , Depressive Disorder/complications , Depressive Disorder/physiopathology , Dopamine/blood , Dysthymic Disorder/blood , Dysthymic Disorder/complications , Dysthymic Disorder/physiopathology , Female , Glutamic Acid/blood , Humans , Middle Aged , Norepinephrine/blood , Serotonin/blood , gamma-Aminobutyric Acid/blood
15.
Scand J Clin Lab Invest ; 81(7): 564-572, 2021 Nov.
Article En | MEDLINE | ID: mdl-34570657

BACKGROUND: Accurate diagnosis of pheochromocytoma and paraganglioma (PPGLs) is highly dependent on the detection of metanephrines and catecholamines. However, the systematic investigation on influencing factors including specimen (plasma or whole blood), anticoagulant, storage conditions, and interference factors need further confirmation. METHODS: Blood with heparin-lithium or EDTA-K2 were collected, stability of epinephrine (EPI), norepinephrine (NE), dopamine (DA), metanephrine (MN), normetanephrine (NMN), 3-methoxytyramine (3-MT) in whole blood and plasma at room temperature and 4 °C for different storage times, stability of plasma MN, NMN and 3-MT at -20 °C and -80 °C were investigated. Plasma with hemoglobin (1 g/L, 2 g/L, 3 g/L, 4 g/L, 6 g/L), TG (<5 mmol/L, 5-8 mmol/L, >8 mmol/L) were prepared. RESULTS: EPI, NE, DA were prone to degrade at room temperature, samples should be centrifuged at 4 °C. EPI and NE were stable in whole blood at 4 °C for 4 h and in plasma for 2 h. For MN, NMN, 3-MT, plasma can be stable at room temperature and 4 °C for at least 6 h, which is better than whole blood; there was no significant difference when stored at -20 °C and -80 °C for 7 days. Heparin-lithium had a slight advantage over EDTA-K2. EPI, NE, DA should not be performed when Hb > 1 g/L or TG > 5 mmol/L. MN, NMN, 3-MT should not be performed when Hb > 2 g/L, whereas TG had no interference. CONCLUSIONS: According to the actual clinical application scenario, this study provided a reliable basis for the accurate diagnosis of PPGLs.


Adrenal Gland Neoplasms/diagnosis , Catecholamines/blood , Dopamine/analogs & derivatives , Metanephrine/blood , Paraganglioma/diagnosis , Pheochromocytoma/diagnosis , Adrenal Gland Neoplasms/blood , Anticoagulants/pharmacology , Dopamine/blood , Epinephrine/blood , Hemoglobins/analysis , Humans , Metabolome , Norepinephrine/blood , Normetanephrine/blood , Paraganglioma/blood , Pheochromocytoma/blood , Triglycerides/blood
16.
Parkinsonism Relat Disord ; 91: 48-54, 2021 10.
Article En | MEDLINE | ID: mdl-34482194

INTRODUCTION: In dystonia, dopaminergic alterations are considered to be responsible for the motor symptoms. Recent attention for the highly prevalent non-motor symptoms suggest also a role for serotonin in the pathophysiology. In this study we investigated the dopaminergic, serotonergic and noradrenergic metabolism in blood samples of dystonia patients and its relation with (non-)motor manifestations. METHODS: Concentrations of metabolites of dopaminergic, serotonergic and noradrenergic pathways were measured in platelet-rich plasma in 41 myoclonus-dystonia (M-D), 25 dopa-responsive dystonia (DRD), 50 cervical dystonia (CD) patients and 55 healthy individuals. (Non-)motor symptoms were assessed using validated instruments, and correlated with concentrations of metabolites. RESULTS: A significantly higher concentration of 3-methoxytyramine (0.03 vs. 0.02 nmol/L, p < 0.01), a metabolite of dopamine, and a reduced concentration of tryptophan (50 vs. 53 µmol/L, p = 0.03), the precursor of serotonin was found in dystonia patients compared to controls. The dopamine/levodopa ratio was higher in CD patients compared to other dystonia groups (p < 0.01). Surprisingly, relatively high concentrations of levodopa were found in the untreated DRD patients. Low concentrations of levodopa were associated with severity of dystonia (rs = -0.3, p < 0.01), depression (rs = -0.3, p < 0.01) and fatigue (rs = -0.2, p = 0.04). CONCLUSION: This study shows alterations in the dopaminergic and serotonergic metabolism of patients with dystonia, with dystonia subtype specific changes. Low concentrations of levodopa, but not of serotonergic metabolites, were associated with both motor and non-motor symptoms. Further insight into the dopaminergic and serotonergic systems in dystonia with a special attention to the kinetics of enzymes involved in these pathways, might lead to better treatment options.


Dopamine/blood , Dystonic Disorders/blood , Levodopa/blood , Serotonin/blood , Torticollis/blood , Adolescent , Adult , Aged , Aged, 80 and over , Case-Control Studies , Child , Dystonic Disorders/drug therapy , Female , Humans , Levodopa/therapeutic use , Male , Middle Aged , Motor Activity/drug effects , Motor Activity/physiology , Torticollis/drug therapy , Young Adult
17.
Mikrochim Acta ; 188(9): 315, 2021 Aug 30.
Article En | MEDLINE | ID: mdl-34462824

Selective and sensitive dopamine (DPA) sensor was developed using hydrothermally prepared functionalized multi-walled carbon nanotube-coated bismuth molybdate (f-MWCNT@BMO). The f-MWCNT@BMO-reinforced electrode exhibited an outstanding electrocatalytic activity towards DPA oxidation. The nanocomposite-reinforced electrode displayed a rapid response towards DPA sensing and possessed the minimized potential of (Epa + 0.285 V vs Ag/AgCl) in 0.1 M phosphate buffer (PB). The electrochemical results of prepared sensors were analyzed using the differential pulse voltammetry method (DPV). As a result, the f-MWCNT@BMO-reinforced electrode exhibited a widelinear range of 10 nM - 814 µM with a very low detection limit of 3.4 nM towards DPA oxidation. The developed sensor shows excellent selectivity in presence of similar functional group biomolecules. The detection of DPA in real samples was evaluated in human serum, as the results of the proposed sensor possessed good recoveries.


Dopamine/blood , Nanocomposites/chemistry , Nanotubes, Carbon/chemistry , Bismuth/chemistry , Dopamine/chemistry , Electrochemical Techniques/instrumentation , Electrochemical Techniques/methods , Electrodes , Humans , Limit of Detection , Molybdenum/chemistry , Oxidation-Reduction , Reproducibility of Results
18.
Anal Bioanal Chem ; 413(21): 5309-5320, 2021 Sep.
Article En | MEDLINE | ID: mdl-34263347

Although many satisfactory studies have been developed for biomolecule detection, the complexity of biofluids still poses a major challenge to improve the performance of nanomaterials as electrochemical sensors. Herein, unprecedented polyoxometalate-based metal-organic frameworks (POMOFs) with 8-fold meso-helical feature, [Ag5(trz)4]2[PMo12O40] (PAZ), were synthesized and explored as electrochemical sensors to detect dopamine (DA). To improve the conductivity of PAZ and the binding ability with single-walled carbon nanotubes (SWCNTs), the nanocomposite of carboxyl functionalized SWCNTs (SWCNTs-COOH) with nano-PAZ (NPAZ), NPAZ@SWCNTs-COOH, was fabricated, and transmission electron microscopy (TEM) shows that NPAZ can interact stably and uniformly with SWCNTs-COOH, owing to more defect sites on the surface of SWCNTs-COOH. The electrochemical result of NPAZ@SWCNTs-COOH/GCE towards detecting DA shows that the linear range was from 0.05 to 100 µM with a detection limit (LOD) of 8.6 nM (S/N = 3). A new electrochemical biosensing platform by combining 8-fold helical POMOFs with SWCNTs-COOH was developed for enhancing detection of dopamine for the first time, exhibiting the lowest detection limit to date.


Anions/chemistry , Dopamine/blood , Metal-Organic Frameworks/chemistry , Nanotubes, Carbon/chemistry , Polyelectrolytes/chemistry , Dopamine/analysis , Electrochemical Techniques/methods , Humans , Limit of Detection
19.
Sci Rep ; 11(1): 14706, 2021 07 19.
Article En | MEDLINE | ID: mdl-34282182

Diagnosis of pheochromocytomas and paragangliomas in patients receiving hemodialysis is troublesome. The aim of the study was to establish optimal conditions for blood sampling for mass spectrometric measurements of normetanephrine, metanephrine and 3-methoxytyramine in patients on hemodialysis and specific reference intervals for plasma metanephrines under the most optimal sampling conditions. Blood was sampled before and near the end of dialysis, including different sampling sites in 170 patients on hemodialysis. Plasma normetanephrine concentrations were lower (P < 0.0001) and metanephrine concentrations higher (P < 0.0001) in shunt than in venous blood, with no differences for 3-methoxytyramine. Normetanephrine, metanephrine and 3-methoxytyramine concentrations in shunt and venous blood were lower (P < 0.0001) near the end than before hemodialysis. Upper cut-offs for normetanephrine were 34% lower when the blood was drawn from the shunt and near the end of hemodialysis compared to blood drawn before hemodialysis. This study establishes optimal sampling conditions using blood from the dialysis shunt near the end of hemodialysis with optimal reference intervals for plasma metanephrines for the diagnosis of pheochromocytomas/paragangliomas among patients on hemodialysis.


Blood Specimen Collection , Metanephrine/blood , Renal Dialysis , Adrenal Gland Neoplasms/blood , Adrenal Gland Neoplasms/diagnosis , Aged , Aged, 80 and over , Blood Chemical Analysis/methods , Blood Chemical Analysis/standards , Blood Specimen Collection/methods , Blood Specimen Collection/standards , Calibration , Dopamine/analogs & derivatives , Dopamine/analysis , Dopamine/blood , Female , Humans , Male , Metanephrine/analysis , Middle Aged , Paraganglioma/blood , Paraganglioma/diagnosis , Pheochromocytoma/blood , Pheochromocytoma/diagnosis , Poland , Pre-Analytical Phase/methods , Pre-Analytical Phase/standards , Reference Values , Tandem Mass Spectrometry/methods , Tandem Mass Spectrometry/standards
20.
Molecules ; 26(9)2021 May 06.
Article En | MEDLINE | ID: mdl-34066584

The sensitive and selective detection of dopamine (DA) is very important for the early diagnosis of DA-related diseases. In this study, we reported the colorimetric detection of DA using Ganoderma lucidum polysaccharide (GLP) stabilized platinum nanoclusters (Ptn-GLP NCs). When Pt600-GLP NCs was added, 3,3',5,5'-tetramethylbenzidine (TMB) was rapidly catalyzed and oxidized to blue oxTMB, indicating the peroxidase-like activity of Pt600-GLP NCs. The catalytic reaction on the substrate TMB followed the Michaelis-Menton kinetics with the ping-pong mechanism. The mechanism of the colorimetric reaction was mainly due to the formation of hydroxyl radical (•OH). Furthermore, the catalytic reaction of Pt600-GLP NCs was used in the colorimetric detection of DA. The linear range for DA was 1-100 µM and the detection limit was 0.66 µM. The sensitive detection of DA using Pt-GLP NCs with peroxidase-like activity offers a simple and practical method that may have great potential applications in the biotechnology field.


Benzidines/chemistry , Dopamine/analysis , Dopamine/blood , Peroxidase/chemistry , Polysaccharides/chemistry , Reishi/chemistry , Brain Diseases/metabolism , Catalysis , Colorimetry , Humans , Kinetics , Limit of Detection , Molecular Weight , Nanoparticles/chemistry , Oxidoreductases/chemistry , Spectroscopy, Fourier Transform Infrared , Temperature
...