Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 12.310
Filter
2.
Circ Cardiovasc Imaging ; 17(6): e016596, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38868952

ABSTRACT

BACKGROUND: Mental stress-induced myocardial ischemia (MSIMI) is associated with adverse cardiovascular outcomes in individuals with coronary artery disease, but the mechanisms underlying this phenomenon are unknown. We examined the relationship between stress-induced autonomic dysfunction, measured by low heart rate variability (HRV) in response to stress, and MSIMI in patients with stable coronary artery disease. We hypothesized that stress-induced autonomic dysfunction is associated with higher odds of MSIMI. METHODS: In 735 participants with stable coronary artery disease, we measured high- and low-frequency HRV in 5-minute intervals before and during a standardized laboratory-based speech stressor using Holter monitoring. HRV at rest and stress were categorized into low HRV (first quartile) versus high HRV (second to fourth quartiles); the low category was used as an indicator of autonomic dysfunction. Multivariable logistic regression models were used to examine the association of autonomic dysfunction with MSIMI. RESULTS: The mean age was 58 (SD, ±10) years, 35% were women, 44% were Black participants, and 16% developed MSIMI. Compared with high HRV during stress, low HRV during stress (both high and low frequencies) was associated with higher odds of MSIMI after adjusting for demographic and clinical factors (odds ratio for high-frequency HRV, 2.1 [95% CI, 1.3-3.3]; odds ratio for low-frequency HRV, 2.1 [95% CI, 1.3-3.3]). Low-frequency HRV at rest was also associated with MSIMI but with slightly reduced effect estimates. CONCLUSIONS: In individuals with coronary artery disease, mental stress-induced autonomic dysfunction may be a mechanism implicated in the causal pathway of MSIMI.


Subject(s)
Autonomic Nervous System , Coronary Artery Disease , Electrocardiography, Ambulatory , Heart Rate , Myocardial Ischemia , Stress, Psychological , Humans , Female , Male , Middle Aged , Coronary Artery Disease/physiopathology , Coronary Artery Disease/complications , Coronary Artery Disease/psychology , Heart Rate/physiology , Stress, Psychological/complications , Stress, Psychological/physiopathology , Autonomic Nervous System/physiopathology , Myocardial Ischemia/physiopathology , Myocardial Ischemia/complications , Myocardial Ischemia/diagnosis , Aged , Risk Factors , Autonomic Nervous System Diseases/physiopathology , Autonomic Nervous System Diseases/diagnosis , Autonomic Nervous System Diseases/etiology
3.
J Am Heart Assoc ; 13(12): e034893, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38879447

ABSTRACT

BACKGROUND: Advanced atrioventricular block (AVB), that is, higher than second-degree Mobitz-1, is an abnormal finding in athletes. Despite intensive investigation, in several cases the pathogenesis remains unknown, but frequently pacemaker implantation is still indicated. Increasing evidence points to circulating anti-Ro/Sjögren syndrome-related antigen A (SSA) antibodies cross-reacting with L-type calcium channel and inhibiting the related current as an epidemiologically relevant and potentially reversible cause of isolated AVB in adults. The aim of the study was to determine the prevalence of anti-Ro/SSA-associated advanced AVBs in a large sample of young athletes. METHODS AND RESULTS: A total of 2536 consecutive athletes aged <40 years without a history of cardiac diseases/interventions were enrolled in a cross-sectional study. Resting and exercise electrocardiography was performed, and those presenting any AVB were further evaluated by 24-hour Holter ECG. Athletes with second-degree AVBs and their mothers underwent anti-Ro/SSA testing. Moreover, purified immunoglobulin G from subjects with anti-Ro/SSA-positive and anti-Ro/SSA-negative advanced AVB were tested on L-type calcium current and L-type-calcium channel expression using tSA201 cells. The global prevalence of advanced AVB in the overall sample was ≈0.1%, but the risk considerably increased (2%) when intensely trained postpubertal male subjects were selectively considered. While none of the athletes with advanced AVB showed heart abnormalities, in 100% of cases anti-Ro/SSA antibodies were detected. Ex vivo experiments showed that immunoglobulin G from anti-Ro/SSA-positive but not -negative subjects with advanced AVB acutely inhibit L-type calcium current and chronically downregulate L-type-calcium channel expression. CONCLUSIONS: Our study provides evidence that advanced AVB occurs in young athletes, in most cases associated with anti-Ro/SSA antibodies blocking L-type calcium channels. These findings may open new avenues for immunomodulating therapies to reduce the risk of life-threatening events in athletes, avoiding or delaying pacemaker implantation.


Subject(s)
Antibodies, Antinuclear , Athletes , Atrioventricular Block , Calcium Channels, L-Type , Humans , Male , Female , Adult , Cross-Sectional Studies , Atrioventricular Block/immunology , Atrioventricular Block/epidemiology , Atrioventricular Block/diagnosis , Prevalence , Young Adult , Calcium Channels, L-Type/immunology , Antibodies, Antinuclear/blood , Antibodies, Antinuclear/immunology , Adolescent , Electrocardiography, Ambulatory , Ribonucleoproteins/immunology
4.
Ann Noninvasive Electrocardiol ; 29(4): e13132, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38888254

ABSTRACT

OBJECTIVES: This study aimed to retrospectively assess cardiac autonomic activity in children with LQTS, considering genotype, symptoms, sex, age, and beta-blocker therapy (BB) and compare it to healthy controls. METHODS: Heart rate variability (HRV), using power spectrum analysis, was analyzed in 575 Holter recordings from 116 children with LQTS and in 69 healthy children. The data were categorized into four age-groups and four heart rate (HR) ranges. RESULTS: In LQT1 and LQT2, increasing HR corresponded to significantly lower low (LF) and high frequency (HF) compared to controls. Total power (PTOT) was lower in all LQT1 age-groups compared to controls at HR 120-140 bpm (1-15 years: p < .01; 15-18 years: p = .03). At HR 80-100, LQT1 patients aged 1-10 years had lower HF than LQT2 patients (1-5 years: p = .05; 5-10 years: p = .02), and LQT2 patients aged 15-18 years had lower HF than LQT1 patients (p < .01). Symptomatic patients aged 10-15 years had lower PTOT at HR 100-120 bpm than asymptomatic patients (p = .04). LQT1 girls aged 10-15 and 15-18 years had a lower PTOT (10-15 years: p = .04; 15-18 years: p = .02) than boys. CONCLUSION: This study shows a correlation between HR and changes in HRV parameters. At higher HRs, LQTS patients generally had lower HRV values than controls, suggesting an abnormal autonomic response. These results may strengthen the link between physical activity and arrhythmias in LQTS.


Subject(s)
Electrocardiography, Ambulatory , Heart Rate , Long QT Syndrome , Humans , Adolescent , Female , Child , Male , Heart Rate/physiology , Electrocardiography, Ambulatory/methods , Long QT Syndrome/physiopathology , Long QT Syndrome/genetics , Retrospective Studies , Child, Preschool , Infant , Case-Control Studies , Adrenergic beta-Antagonists/therapeutic use
5.
Pflugers Arch ; 476(7): 1145-1154, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38703193

ABSTRACT

Arrhythmia detection is essential when assessing the safety of novel drugs and therapies in preclinical studies. Many short-term arrhythmia monitoring methods exist, including non-invasive ECG and Holter. However, there are no reliable, long-term, non-invasive, or minimally invasive methods for cardiac arrhythmia follow-up in large animals that allows free movement with littermates. A long follow-up time is needed when estimating the impact of long-lasting drugs or therapies, such as gene therapy. We evaluated the feasibility and performance of insertable cardiac monitors (ICMs) in pigs for minimally invasive, long-term monitoring of cardiac arrhythmias that allows free movement and species-specific behavior. Multiple implantation sites were tested to assess signal quality. ICMs recognized reliably many different arrhythmias but failed to detect single extrasystoles. They also over-diagnosed T-waves, resulting in oversensing. Muscle activity and natural startles of the animals caused noise, leading to a heterogeneous signal requiring post-recording evaluation. In spite of these shortcomings, the ICMs showed to be very useful for minimally invasive long-term monitoring of cardiac rhythm in pigs.


Subject(s)
Arrhythmias, Cardiac , Animals , Swine , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Electrocardiography, Ambulatory/instrumentation , Electrocardiography, Ambulatory/methods , Electrocardiography/methods , Electrocardiography/instrumentation , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Monitoring, Physiologic/veterinary
6.
Pediatr Neurol ; 156: 53-58, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38733854

ABSTRACT

BACKGROUND: Breath-holding spells are a benign condition primarily seen in 3% to 5% of healthy children aged between six months and five years. Although no specific treatment is recommended due to its benign nature, iron and piracetam are used in severe or recurrent cases. We planned to compare the heart rate variability (HRV) before and after treatment with 24-hour Holter monitoring in patients receiving iron and piracetam treatment and investigate the treatment's effectiveness. METHODS: Twenty-five patients who applied to the outpatient clinic between 2013 and 2015 due to breath-holding spells were included in the study. The patients who received piracetam and iron therapy and underwent 24-hour rhythm Holter monitoring were evaluated retrospectively. RESULTS: Fourteen (56%) of these patients were evaluated as having cyanotic-type and 11 (44%) patients were assessed as having pale-type breath-holding spells. A significant difference was found only between hourly peak heart rate and total power in the group receiving iron treatment. Significant differences were also found among the minimum heart rate, mean heart rate, the standard deviation of RR intervals, the mean square root of the sum of the squares of their difference between adjacent RR intervals, spectpow, and low frequency before and after the treatment in the patients who started piracetam treatment (P < 0.05). CONCLUSIONS: Our study is critical as it is the first to investigate the effects of treatment options on various HRV in patients with breath-holding spells. There were statistically significant changes in HRV parameters in patients receiving piracetam, and the number of attacks decreased significantly. Piracetam treatment contributes positively to the breath-holding spell with regard to efficacy and HRV, therefore it can be used to treat breath-holding spells.


Subject(s)
Breath Holding , Heart Rate , Piracetam , Humans , Heart Rate/drug effects , Heart Rate/physiology , Breath Holding/drug effects , Male , Female , Child, Preschool , Retrospective Studies , Infant , Piracetam/pharmacology , Piracetam/administration & dosage , Piracetam/therapeutic use , Electrocardiography, Ambulatory/drug effects , Treatment Outcome , Iron/administration & dosage , Iron/pharmacology
7.
J Am Heart Assoc ; 13(11): e032465, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38804218

ABSTRACT

BACKGROUND: New methods to identify patients who benefit from a primary prophylactic implantable cardioverter-defibrillator (ICD) are needed. T-wave alternans (TWA) has been shown to associate with arrhythmogenesis of the heart and sudden cardiac death. We hypothesized that TWA might be associated with benefit from ICD implantation in primary prevention. METHODS AND RESULTS: In the EU-CERT-ICD (European Comparative Effectiveness Research to Assess the Use of Primary Prophylactic Implantable Cardioverter-Defibrillators) study, we prospectively enrolled 2327 candidates for primary prophylactic ICD. A 24-hour Holter monitor reading was taken from all recruited patients at enrollment. TWA was assessed from Holter monitoring using the modified moving average method. Study outcomes were all-cause death, appropriate shock, and survival benefit. TWA was assessed both as a contiguous variable and as a dichotomized variable with cutoff points <47 µV and <60 µV. The final cohort included 1734 valid T-wave alternans samples, 1211 patients with ICD, and 523 control patients with conservative treatment, with a mean follow-up time of 2.3 years. TWA ≥60 µV was a predicter for a higher all-cause death in patients with an ICD on the basis of a univariate Cox regression model (hazard ratio, 1.484 [95% CI, 1.024-2.151]; P=0.0374; concordance statistic, 0.51). In multivariable models, TWA was not prognostic of death or appropriate shocks in patients with an ICD. In addition, TWA was not prognostic of death in control patients. In a propensity score-adjusted Cox regression model, TWA was not a predictor of ICD benefit. CONCLUSIONS: T-wave alternans is poorly prognostic in patients with a primary prophylactic ICD. Although it may be prognostic of life-threatening arrhythmias and sudden cardiac death in several patient populations, it does not seem to be useful in assessing benefit from ICD therapy in primary prevention among patients with an ejection fraction of ≤35%.


Subject(s)
Death, Sudden, Cardiac , Defibrillators, Implantable , Electrocardiography, Ambulatory , Primary Prevention , Humans , Primary Prevention/methods , Male , Female , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Middle Aged , Aged , Prospective Studies , Electrocardiography, Ambulatory/methods , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Risk Assessment/methods , Risk Factors , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/prevention & control , Arrhythmias, Cardiac/mortality , Treatment Outcome , Predictive Value of Tests , Time Factors , Europe/epidemiology , Prognosis , Heart Rate/physiology
8.
BMC Cardiovasc Disord ; 24(1): 257, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38760695

ABSTRACT

BACKGROUND: This study aimed to investigate the potential association between the circadian rhythm of blood pressure and deceleration capacity (DC)/acceleration capacity (AC) in patients with essential hypertension. METHODS: This study included 318 patients with essential hypertension, whether or not they were being treated with anti-hypertensive drugs, who underwent 24-hour ambulatory blood pressure monitoring (ABPM). Patients were categorized into three groups based on the percentage of nocturnal systolic blood pressure (SBP) dipping: the dipper, non-dipper and reverse dipper groups. Baseline demographic characteristics, ambulatory blood pressure monitoring parameters, Holter recordings (including DC and AC), and echocardiographic parameters were collected. RESULTS: In this study, the lowest DC values were observed in the reverse dipper group, followed by the non-dipper and dipper groups (6.46 ± 2.06 vs. 6.65 ± 1.95 vs. 8.07 ± 1.79 ms, P < .001). Additionally, the AC gradually decreased (-6.32 ± 2.02 vs. -6.55 ± 1.95 vs. -7.80 ± 1.73 ms, P < .001). There was a significant association between DC (r = .307, P < .001), AC (r=-.303, P < .001) and nocturnal SBP decline. Furthermore, DC (ß = 0.785, P = .001) was positively associated with nocturnal SBP decline, whereas AC was negatively associated with nocturnal SBP (ß = -0.753, P = .002). By multivariate logistic regression analysis, deceleration capacity [OR (95% CI): 0.705 (0.594-0.836), p < .001], and acceleration capacity [OR (95% CI): 1.357 (1.141-1.614), p = .001] were identified as independent risk factors for blood pressure nondipper status. The analysis of ROC curves revealed that the area under the curve for DC/AC in predicting the circadian rhythm of blood pressure was 0.711/0.697, with a sensitivity of 73.4%/65.1% and specificity of 66.7%/71.2%. CONCLUSIONS: Abnormal DC and AC density were correlated with a blunted decline in nighttime SBP, suggesting a potential association between the circadian rhythm of blood pressure in essential hypertension patients and autonomic nervous dysfunction.


Subject(s)
Antihypertensive Agents , Blood Pressure Monitoring, Ambulatory , Blood Pressure , Circadian Rhythm , Essential Hypertension , Heart Rate , Humans , Male , Female , Middle Aged , Essential Hypertension/physiopathology , Essential Hypertension/diagnosis , Essential Hypertension/drug therapy , Time Factors , Antihypertensive Agents/therapeutic use , Aged , Predictive Value of Tests , Adult , Risk Factors , Electrocardiography, Ambulatory , Acceleration , Deceleration
9.
Arch Cardiovasc Dis ; 117(5): 313-320, 2024 May.
Article in English | MEDLINE | ID: mdl-38704288

ABSTRACT

BACKGROUND: In patients with congenital long QT syndrome (LQTS), the risk of ventricular arrhythmia is correlated with the duration of the corrected QT interval and the changes in the ST-T wave pattern on the 12-lead surface electrocardiogram (12L-ECG). Remote monitoring of these variables could be useful. AIM: To evaluate the abilities of two wearable electrocardiogram devices (Apple Watch and KardiaMobile 6L) to provide reliable electrocardiograms in terms of corrected QT interval and ST-T wave patterns in patients with LQTS. METHODS: In a prospective multicentre study (ClinicalTrials.gov identifier: NCT04728100), a 12L-ECG, a 6-lead KardiaMobile 6L electrocardiogram and two single-lead Apple Watch electrocardiograms were recorded in patients with LQTS. The corrected QT interval and ST-T wave patterns were evaluated manually. RESULTS: Overall, 98 patients with LQTS were included; 12.2% were children and 92.8% had a pathogenic variant in an LQTS gene. The main genotypes were LQTS type 1 (40.8%), LQTS type 2 (36.7%) and LQTS type 3 (7.1%); rarer genotypes were also represented. When comparing the ST-T wave patterns obtained with the 12L-ECG, the level of agreement was moderate with the Apple Watch (k=0.593) and substantial with the KardiaMobile 6L (k=0.651). Regarding the corrected QT interval, the correlation with 12L-ECG was strong for the Apple Watch (r=0.703 in lead II) and moderate for the KardiaMobile 6L (r=0.593). There was a slight overestimation of corrected QT interval with the Apple Watch and a subtle underestimation with the KardiaMobile 6L. CONCLUSIONS: In patients with LQTS, the corrected QT interval and ST-T wave patterns obtained with the Apple Watch and the KardiaMobile 6L correlated with the 12L-ECG. Although wearable electrocardiogram devices cannot replace the 12L-ECG for the follow-up of these patients, they could be interesting additional monitoring tools.


Subject(s)
Heart Rate , Long QT Syndrome , Predictive Value of Tests , Wearable Electronic Devices , Humans , Long QT Syndrome/physiopathology , Long QT Syndrome/diagnosis , Long QT Syndrome/congenital , Long QT Syndrome/genetics , Female , Male , Prospective Studies , Child , Adolescent , Adult , Reproducibility of Results , Young Adult , Electrocardiography, Ambulatory/instrumentation , Action Potentials , Child, Preschool , Equipment Design , Time Factors , Middle Aged , Electrocardiography/instrumentation , Heart Conduction System/physiopathology
10.
Open Heart ; 11(1)2024 May 08.
Article in English | MEDLINE | ID: mdl-38719499

ABSTRACT

OBJECTIVE: Implantable loop recorders (ILRs) are increasingly used for long-term rhythm monitoring after ischaemic and cryptogenic stroke, with the goal of detecting atrial fibrillation (AF) and subsequent initiation of oral anticoagulation to reduce risk of adverse clinical outcomes. There is a need to determine the effectiveness of different rhythm monitoring strategies in this context. METHODS: We conducted a retrospective cohort analysis of individuals with commercial and Medicare Advantage insurance in Optum Labs Data Warehouse who had incident ischaemic or cryptogenic stroke and no prior cardiovascular implantable electronic device from 1 January 2016 to 30 June 2021. Patients were stratified by rhythm monitoring strategy: ILR, long-term continuous external cardiac monitor (>48 hours to 30 days) or Holter monitor (≤48 hours). The primary outcome was risk-adjusted all-cause mortality at 12 months. Secondary outcomes included new diagnosis of AF and oral anticoagulation, bleeding, and costs. RESULTS: Among 48 901 patients with ischaemic or cryptogenic stroke, 9235 received an ILR, 29 103 long-term continuous external monitor and 10 563 Holter monitor only. Mean age was 69.9 (SD 11.9) years and 53.5% were female. During the 12-month follow-up period, patients who received ILRs compared with those who received long-term continuous external monitors had a higher odds of new diagnosis of AF and oral anticoagulant initiation (adjusted OR 2.27, 95% CI 2.09 to 2.48). Compared with patients who received long-term continuous external monitors, those who received ILRs had similar 12-month mortality (HR 1.00; 95% CI 0.89 to 1.12), with approximately $13 000 higher costs at baseline (including monitor cost) and $2500 higher costs during 12-month follow-up. CONCLUSIONS: In this large real-world study of patients with ischaemic or cryptogenic stroke, ILR placement resulted in more diagnosis of AF and initiation of oral anticoagulation, but no difference in mortality compared with long-term continuous external monitors.


Subject(s)
Atrial Fibrillation , Electrocardiography, Ambulatory , Ischemic Stroke , Humans , Female , Male , Aged , Retrospective Studies , Electrocardiography, Ambulatory/instrumentation , Electrocardiography, Ambulatory/economics , Electrocardiography, Ambulatory/methods , Ischemic Stroke/economics , Ischemic Stroke/mortality , Ischemic Stroke/diagnosis , Ischemic Stroke/prevention & control , Ischemic Stroke/etiology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/economics , Atrial Fibrillation/drug therapy , Atrial Fibrillation/complications , Atrial Fibrillation/mortality , United States/epidemiology , Anticoagulants/economics , Anticoagulants/administration & dosage , Time Factors , Middle Aged , Follow-Up Studies , Cost-Benefit Analysis , Aged, 80 and over , Health Care Costs
11.
EuroIntervention ; 20(9): 591-601, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726722

ABSTRACT

BACKGROUND: Little is known about the occurrence of subclinical new-onset atrial fibrillation (NOAF) after transcatheter aortic valve implantation (TAVI). AIMS: We aimed to evaluate the incidence, predictors, and clinical impact of subclinical NOAF after TAVI. METHODS: This was a multicentre study, including patients with aortic stenosis (AS) and no previous atrial fibrillation undergoing TAVI, with continuous ambulatory electrocardiogram (AECG) monitoring after TAVI. RESULTS: A total of 700 patients (79±8 years, 49% female, Society of Thoracic Surgeons score 2.9% [1.9-4.0]) undergoing transarterial TAVI were included (85% balloon-expandable valves). AECG was started 1 (0-1) day after TAVI (monitoring time: 14121314 days). NOAF was detected in 49 patients (7%), with a median duration of 185 (43-421) minutes (atrial fibrillation burden of 0.7% [0.3-2.8]). Anticoagulation was started in 25 NOAF patients (51%). No differences were found in baseline or procedural characteristics, except for a higher AS severity in the NOAF group (peak gradient: no NOAF: 71.9±23.5 mmHg vs NOAF: 85.2±23.8 mmHg; p=0.024; mean gradient: no NOAF: 44.4±14.7 mmHg vs NOAF: 53.8±16.8 mmHg; p=0.004). In the multivariable analysis, the baseline mean transaortic gradient was associated with a higher risk of NOAF after TAVI (odds ratio 1.04, 95% confidence interval: 1.01-1.06 for each mmHg; p=0.006). There were no differences between groups in all-cause mortality (no NOAF: 4.7% vs NOAF: 0%; p=0.122), stroke (no NOAF: 1.4% vs NOAF: 2.0%; p=0.723), or bleeding (no NOAF: 1.9% vs NOAF: 4.1%; p=0.288) from the 30-day to 1-year follow-up. CONCLUSIONS: NOAF detected with AECG occurred in 7% of TAVI recipients and was associated with a higher AS severity. NOAF detection determined the start of anticoagulation therapy in about half of the patients, and it was not associated with an increased risk of clinical events at 1-year follow-up.


Subject(s)
Aortic Valve Stenosis , Atrial Fibrillation , Electrocardiography, Ambulatory , Transcatheter Aortic Valve Replacement , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Female , Male , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Aortic Valve Stenosis/surgery , Aged, 80 and over , Electrocardiography, Ambulatory/methods , Risk Factors , Treatment Outcome
12.
Scand Cardiovasc J ; 58(1): 2353069, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38794854

ABSTRACT

OBJECTIVES: Atrial fibrillation (AF) is a common early arrhythmia after heart valve surgery that limits physical activity. We aimed to evaluate the criterion validity of the Apple Watch Series 5 single-lead electrocardiogram (ECG) for detecting AF in patients after heart valve surgery. DESIGN: We enrolled 105 patients from the University Hospital of North Norway, of whom 93 completed the study. All patients underwent single-lead ECG using the smartwatch three times or more daily on the second to third or third to fourth postoperative day. These results were compared with continuous 2-4 days ECG telemetry monitoring and a 12-lead ECG on the third postoperative day. RESULTS: On comparing the Apple Watch ECGs with the ECG monitoring, the sensitivity and specificity to detect AF were 91% (75, 100) and 96% (91, 99), respectively. The accuracy was 95% (91, 99). On comparing Apple Watch ECG with a 12-lead ECG, the sensitivity was 71% (62, 100) and the specificity was 92% (92, 100). CONCLUSION: The Apple smartwatch single-lead ECG has high sensitivity and specificity, and might be a useful tool for detecting AF in patients after heart valve surgery.


Subject(s)
Atrial Fibrillation , Heart Rate , Predictive Value of Tests , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Male , Prospective Studies , Female , Aged , Middle Aged , Reproducibility of Results , Norway , Time Factors , Mobile Applications , Treatment Outcome , Electrocardiography, Ambulatory/instrumentation , Telemetry/instrumentation , Cardiac Surgical Procedures/adverse effects , Wearable Electronic Devices , Electrocardiography , Heart Valves/surgery , Heart Valves/physiopathology
13.
J Med Syst ; 48(1): 57, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38801649

ABSTRACT

Wearable electronics are increasingly common and useful as health monitoring devices, many of which feature the ability to record a single-lead electrocardiogram (ECG). However, recording the ECG commonly requires the user to touch the device to complete the lead circuit, which prevents continuous data acquisition. An alternative approach to enable continuous monitoring without user initiation is to embed the leads in a garment. This study assessed ECG data obtained from the YouCare device (a novel sensorized garment) via comparison with a conventional Holter monitor. A cohort of thirty patients (age range: 20-82 years; 16 females and 14 males) were enrolled and monitored for twenty-four hours with both the YouCare device and a Holter monitor. ECG data from both devices were qualitatively assessed by a panel of three expert cardiologists and quantitatively analyzed using specialized software. Patients also responded to a survey about the comfort of the YouCare device as compared to the Holter monitor. The YouCare device was assessed to have 70% of its ECG signals as "Good", 12% as "Acceptable", and 18% as "Not Readable". The R-wave, independently recorded by the YouCare device and Holter monitor, were synchronized within measurement error during 99.4% of cardiac cycles. In addition, patients found the YouCare device more comfortable than the Holter monitor (comfortable 22 vs. 5 and uncomfortable 1 vs. 18, respectively). Therefore, the quality of ECG data collected from the garment-based device was comparable to a Holter monitor when the signal was sufficiently acquired, and the garment was also comfortable.


Subject(s)
Electrocardiography, Ambulatory , Electrocardiography , Humans , Female , Male , Middle Aged , Aged , Adult , Electrocardiography, Ambulatory/instrumentation , Electrocardiography, Ambulatory/methods , Aged, 80 and over , Electrocardiography/instrumentation , Electrocardiography/methods , Wearable Electronic Devices , Young Adult , Clothing , Signal Processing, Computer-Assisted/instrumentation
14.
Open Heart ; 11(1)2024 May 07.
Article in English | MEDLINE | ID: mdl-38719497

ABSTRACT

BACKGROUND: The treatment of pulmonary hypertension (PH) has improved rapidly in recent decades. There is increasing evidence to support the role of early intervention and treatment in affecting clinical outcomes in PH. OBJECTIVES: To assess treatment effects before and after the escalation of specific PH treatments using continuous heart monitoring with a Reveal LINQ loop recorder. METHODS: Patients were compared before and after treatment escalation. Treatment escalation was defined as an additional pulmonary arterial hypertension (PAH) drug, pulmonary endarterectomy, percutaneous balloon angioplasty or bilateral lung transplantation. Specifically, changes in heart rate variability (HRV), heart rate (HR) and physical activity were assessed. RESULTS: In this prospective study, 41 patients (27 with PAH and 14 with chronic thromboembolic pulmonary hypertension (CTEPH)) were enrolled. Among them, 15 (36.6%) patients underwent PH treatment escalation. Prior to escalation, patients were monitored for a median of 100 (range: 68-100) days and after therapy escalation for a median duration of 165 (range: 89-308) days. In the escalation group, there was a significant increase in HRV, physical activity indexed by daytime HR and a significant decrease in nighttime HR assessed at baseline and after treatment escalation in both the PAH and CTEPH groups. This was paralleled by significant improvements in WHO functional class, 6-min walking distance and N-terminal pro-b-type natriuretic peptide. CONCLUSIONS: This is the first study to demonstrate an association between specific PH therapies and changes in HRV, HR nighttime and physical activity. This indicates the potential of continuous monitoring in the evaluation of treatment effects in PH.


Subject(s)
Heart Rate , Hypertension, Pulmonary , Humans , Female , Male , Middle Aged , Prospective Studies , Heart Rate/physiology , Hypertension, Pulmonary/physiopathology , Hypertension, Pulmonary/diagnosis , Hypertension, Pulmonary/therapy , Treatment Outcome , Endarterectomy/methods , Aged , Antihypertensive Agents/therapeutic use , Time Factors , Angioplasty, Balloon/methods , Adult , Lung Transplantation , Electrocardiography, Ambulatory/methods , Pulmonary Artery/physiopathology
15.
Circ Arrhythm Electrophysiol ; 17(5): e012697, 2024 May.
Article in English | MEDLINE | ID: mdl-38629286

ABSTRACT

BACKGROUND: Clinically detected atrial fibrillation (AF) is associated with a significant increase in mortality and other adverse cardiovascular events. Since the advent of effective methods for AF rhythm control, investigators have attempted to determine how much these adverse prognostic AF effects could be mitigated by the restoration of sinus rhythm (SR) and whether the method used mattered. METHODS: The CABANA trial (Catheter Ablation versus Antiarrhythmic Drug Therapy for Atrial Fibrillation) randomized 2204 AF patients to ablation versus drug therapy, of which 1240 patients were monitored in follow-up using the CABANA ECG rhythm monitoring system. To assess the prognostic benefits of SR, we performed a prespecified analysis using Cox survival modeling with heart rhythm as a time-dependent variable and randomized treatment group as a stratification factor. RESULTS: In the 1240 patient study cohort, 883 (71.2%) had documented AF at some point during their postblanking follow-up. Among the 883 patients, 671 (76.0%) experienced AF within the first year of postblanking follow-up, and 212 (24.0%) experienced their first AF after ≥1 year of postblanking follow-up. The primary CABANA end point (death, disabling stroke, serious bleeding, or cardiac arrest) occurred in 95 (10.8%) of the 883 patients with documented AF and in 29 (8.1%) of the 357 patients with no AF recorded during follow-up. In multivariable time-dependent analysis, the presence of SR (compared with non-SR) was associated with a significantly reduced risk of the primary end point (adjusted hazard ratio, 0.57 [95% CI, 0.38-0.85]; P=0.006; independent of treatment strategy [ablation versus drugs]). Corresponding results for all-cause mortality were adjusted hazard ratio of 0.59 [95% CI, 0.35-1.01]; P=0.053). CONCLUSIONS: In patients in the CABANA trial with detailed long-term rhythm follow-up, increased time in SR was associated with a clinically consequential decrease in mortality and other adverse prognostic events. The predictive value of SR was independent of the therapeutic approach responsible for reducing the burden of detectable AF. REGISTRATION: URL: https://clinicaltrials.gov; Unique Identifier: NCT00911508.


Subject(s)
Anti-Arrhythmia Agents , Atrial Fibrillation , Catheter Ablation , Heart Rate , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/mortality , Atrial Fibrillation/therapy , Male , Female , Anti-Arrhythmia Agents/therapeutic use , Middle Aged , Aged , Treatment Outcome , Time Factors , Risk Factors , Prognosis , Risk Assessment , Electrocardiography, Ambulatory , Action Potentials
16.
Pacing Clin Electrophysiol ; 47(6): 843-852, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38630938

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is the most common sustained atrial arrhythmia. Accurate detection of the timing and possibility of AF termination is vital for optimizing rhythm and rate control strategies. The present study evaluated whether the ventricular response (VR) in AF offers a distinctive electrocardiographic indicator for predicting AF termination. METHODS: Patients experiencing sustained paroxysmal AF for more than 3 h were observed using 24-h ambulatory Holter monitoring. VR within 5 min before AF termination (VR 0-5 min, BAFT) was compared with VR observed during the 60th to 65th min (VR 60-65 min, BAFT) and the 120th to 125th min (VR 120-125 min, BAFT) before AF termination. Maximum and minimum VRs were calculated on the basis of the average of the highest and lowest VRs across 10 consecutive heartbeats. RESULTS: Data from 37 episodes of paroxysmal AF revealed that the minimum VR0-5 min, BAFT (64 ± 20 bpm) was significantly faster than both the minimum VR120-125 min, BAFT (56 ± 15 bpm) and the minimum VR60-65 min, BAFT (57 ± 16 bpm, p < .05). Similarly, the maximum VR0-5 min, BAFT (158 ± 49 bpm) was significantly faster than the maximum VR120-125 min, BAFT (148 ± 45 bpm, p < .05). In the daytime, the minimum VR0-5 min, BAFT (66 ± 20 bpm) was significantly faster than both the minimum VR60-65 min, BAFT (58 ± 17 bpm) and minimum VR120-125 min, BAFT (57 ± 15 bpm, p < .05). However, the mean and maximum VR0-5 min, BAFT in the daytime were similar to the mean and maximum VR120-125 min in the daytime, respectively. At night, the minimum, mean, and maximum VR0-5 min, BAFT were similar to the minimum, mean, and maximum VR120-125 min, respectively. CONCLUSIONS: Elevated VR rates during AF episodes may be predictors for the termination of AF, especially during the daytime and in patients with nondilated left atria. These findings may guide the development of clinical approaches to rhythm control in AF.


Subject(s)
Atrial Fibrillation , Electrocardiography, Ambulatory , Humans , Atrial Fibrillation/physiopathology , Male , Female , Middle Aged , Aged , Predictive Value of Tests
17.
IEEE J Biomed Health Inform ; 28(6): 3457-3465, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38557616

ABSTRACT

A novel method for tracking the tidal volume (TV) from electrocardiogram (ECG) is presented. The method is based on the amplitude of ECG-derived respiration (EDR) signals. Three different morphology-based EDR signals and three different amplitude estimation methods have been studied, leading to a total of 9 amplitude-EDR (AEDR) signals per ECG channel. The potential of these AEDR signals to track the changes in TV was analyzed. These methods do not need a calibration process. In addition, a personalized-calibration approach for TV estimation is proposed, based on a linear model that uses all AEDR signals from a device. All methods have been validated with two different ECG devices: a commercial Holter monitor, and a custom-made wearable armband. The lowest errors for the personalized-calibration methods, compared to a reference TV, were -3.48% [-17.41% / 12.93%] (median [first quartile / third quartile]) for the Holter monitor, and 0.28% [-10.90% / 17.15%] for the armband. On the other hand, medians of correlations to the reference TV were higher than 0.8 for uncalibrated methods, while they were higher than 0.9 for personal-calibrated methods. These results suggest that TV changes can be tracked from ECG using either a conventional (Holter) setup, or our custom-made wearable armband. These results also suggest that the methods are not as reliable in applications that induce small changes in TV, but they can be potentially useful for detecting large changes in TV, such as sleep apnea/hypopnea and/or exacerbations of a chronic respiratory disease.


Subject(s)
Electrocardiography, Ambulatory , Signal Processing, Computer-Assisted , Tidal Volume , Wearable Electronic Devices , Humans , Electrocardiography, Ambulatory/instrumentation , Electrocardiography, Ambulatory/methods , Tidal Volume/physiology , Male , Adult , Female , Electrocardiography/methods , Electrocardiography/instrumentation , Middle Aged , Young Adult
18.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38584469

ABSTRACT

AIMS: Brugada syndrome (BrS) diagnosis and risk stratification rely on the presence of a spontaneous type 1 (spT1) electrocardiogram (ECG) pattern; however, its spontaneous fluctuations may lead to misdiagnosis and risk underestimation. This study aims to assess the role for repeat high precordial lead (HPL) resting and ambulatory ECG monitoring in identifying a spT1, and evaluate its prognostic role. METHODS AND RESULTS: HPL resting and ambulatory monitoring ECGs of BrS subjects were reviewed retrospectively, and the presence of a spT1 associated with ventricular dysrhythmias and sudden cardiac death (SCD). Three-hundred and fifty-eight subjects (77 with spT1 pattern at presentation, Group 1, and 281 without, Group 2) were included. In total, 1651 resting HPL resting and 621 ambulatory monitoring ECGs were available for review, or adequately described. Over a median follow-up of 72 months (interquartile range - IQR - 75), 42/77 (55%) subjects in Group 1 showed a spT1 in at least one ECG. In Group 2, 36/281 subjects (13%) had a newly detected spT1 (1.9 per 100 person-year) and 23 on an HPL ambulatory recording (8%). Seven previously asymptomatic subjects, five of whom had a spT1 (four at presentation and one at follow-up), experienced arrhythmic events; survival analysis indicated that a spT1, either at presentation or during lifetime, was associated with events. Univariate models showed that a spT1 was consistently associated with increased risk [spT1 at presentation: hazard ratio (HR) 6.3, 95% confidence interval (CI) 1.4-28, P = 0.016; spT1 at follow-up: HR 3.1, 95% CI 1.3-7.2, P = 0.008]. CONCLUSION: Repeated ECG evaluation and HPL ambulatory monitoring are vital in identifying transient spT1 Brugada pattern and its associated risk.


Subject(s)
Brugada Syndrome , Death, Sudden, Cardiac , Electrocardiography, Ambulatory , Humans , Brugada Syndrome/diagnosis , Brugada Syndrome/physiopathology , Male , Female , Electrocardiography, Ambulatory/methods , Middle Aged , Retrospective Studies , Prognosis , Adult , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Risk Assessment , Predictive Value of Tests , Risk Factors , Heart Rate , Aged
19.
Heart ; 110(12): 831-837, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38580434

ABSTRACT

BACKGROUND: Elevated heart rate (HR) predicts cardiovascular disease and mortality, but there are no established normal limits for ambulatory HR. We used data from the Swedish CArdioPulmonary Imaging Study to determine reference ranges for ambulatory HR in a middle-aged population. We also studied clinical correlates of ambulatory HR. METHODS: A 24-hour ECG was registered in 5809 atrial fibrillation-free individuals, aged 50-65 years. A healthy subset (n=3942) was used to establish reference values (excluding persons with beta-blockers, cardiovascular disease, hypertension, heart failure, anaemia, diabetes, sleep apnoea or chronic obstructive pulmonary disease).Minimum HR was defined as the lowest 1-minute HR. Reference ranges are reported as means±SDs and 2.5th-97.5th percentiles. Clinical correlates of ambulatory HR were analysed with multivariable linear regression. RESULTS: The average mean and minimum HRs were 73±9 and 48±7 beats per minute (bpm) in men and 76±8 and 51±7 bpm in women; the reference range for mean ambulatory HR was 57-90 bpm in men and 61-92 bpm in women. Average daytime and night-time HRs are also reported. Clinical correlates, including age, sex, height, body mass index, physical activity, smoking, alcohol intake, diabetes, hypertension, haemoglobin level, use of beta-blockers, estimated glomerular filtration rate, per cent of predicted forced expiratory volume in 1 s and coronary artery calcium score, explained <15% of the interindividual differences in HR. CONCLUSION: Ambulatory HR varies widely in healthy middle-aged individuals, a finding with relevance for the management of patients with a perception of tachycardia. Differences in ambulatory HR between individuals are largely independent of common clinical correlates.


Subject(s)
Electrocardiography, Ambulatory , Heart Rate , Humans , Male , Female , Middle Aged , Heart Rate/physiology , Reference Values , Aged , Electrocardiography, Ambulatory/methods , Sweden/epidemiology , Age Factors
20.
J Cardiovasc Med (Hagerstown) ; 25(6): 429-437, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38625830

ABSTRACT

AIMS: In this study, we investigated a cohort of unselected patients with various indications for an implantable cardiac monitor (ICM). Our main objectives were to determine the incidence of arrhythmic diagnoses, both anticipated and incidental in relation to the ICM indication, and to assess their clinical relevance. METHODS: We examined remote monitoring transmissions from patients with an ICM at four Italian sites to identify occurrences of cardiac arrhythmias. Concurrently, we collected data on medical actions taken in response to arrhythmic findings. RESULTS: The study included 119 patients, with a median follow-up period of 371 days. ICM indications were syncope/presyncope (46.2%), atrial fibrillation management (31.1%), and cryptogenic stroke (22.7%). In the atrial fibrillation management group, atrial fibrillation was the most common finding, with an incidence of 36% [95% confidence interval (CI) 22-55%] at 18 months. Rates of atrial fibrillation were not significantly different between patients with cryptogenic stroke and syncope/presyncope [17% (95% CI 7-40%) vs. 8% (95% CI 3-19%), P  = 0.229].For patients with cryptogenic stroke, the incidence of asystole and bradyarrhythmias at 18 months was 23% (95% CI 11-45%) and 42% (95% CI 24-65%), respectively, similar to estimates obtained for patients implanted for syncope/presyncope ( P  = 0.277 vs. P  = 0.836).Overall, 30 patients (25.2%) required medical intervention following ICM-detected arrhythmias, predominantly involving atrial fibrillation ablation (10.9%) and medication therapy changes (10.1%). CONCLUSION: In a real-life population with heterogeneous insertion indications, approximately 25% of patients received ICM-guided medical interventions within a short timeframe, including treatments for incidental findings. Common incidental arrhythmic diagnoses were bradyarrhythmias in patients with cryptogenic stroke and atrial fibrillation in patients with unexplained syncope.


Subject(s)
Arrhythmias, Cardiac , Atrial Fibrillation , Electrocardiography, Ambulatory , Syncope , Humans , Male , Female , Aged , Middle Aged , Italy/epidemiology , Electrocardiography, Ambulatory/instrumentation , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/physiopathology , Syncope/diagnosis , Syncope/etiology , Syncope/epidemiology , Syncope/therapy , Syncope/physiopathology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/complications , Atrial Fibrillation/therapy , Atrial Fibrillation/physiopathology , Incidence , Incidental Findings , Bradycardia/diagnosis , Bradycardia/epidemiology , Bradycardia/therapy , Bradycardia/physiopathology , Aged, 80 and over , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...