1.
J Robot Surg ; 18(1): 273, 2024 Jun 29.
Article in English | MEDLINE | ID: mdl-38949665

ABSTRACT

Robotic assistance for total hip arthroplasty (THA) has been demonstrated to improve accuracy of acetabular cup placement relative to manual, unassisted technique. The purpose of this investigation was to compare the accuracy and precision between a fluoroscopy-based robotic total hip arthroplasty platform (FL-RTHA) and a computerized tomography-based (CT-RTHA) platform. The study included 98 consecutive FL-RTHA and 159 CT-RTHA procedures performed via direct anterior approach (DAA). All cases were performed for a pre-operative diagnosis of osteoarthritis, avascular necrosis, or rheumatoid arthritis. Primary outcome variables included cup implantation accuracy and precision (variance). Implantation accuracy was calculated as the absolute value of the difference between pre-operative target cup angles (inclination and anteversion) and the same post-operative angles. Percentage placement in the Lewinnek safe zone was also measured for both cohorts. The FL-RTHA and CT-RTHA cohorts demonstrated a 1.2° difference in absolute values for cup inclination accuracy (4.6° ± 3.6 vs. 3.4 ± 2.7; p = 0.005), and no difference in absolute values for cup anteversion accuracy (4.7° ± 4.1 vs. 4.6 ± 3.4; p = 0.991). Cohorts demonstrated similar precision for cup inclination and anteversion placement parameters, as well as equivalent Lewinnek safe zone placement. The use of a fluoroscopy-based robotic assistance platform for primary DAA THA resulted in similar accuracy and precision of acetabular cup placement when compared to a CT-based robotic assistance system.


Subject(s)
Arthroplasty, Replacement, Hip , Robotic Surgical Procedures , Tomography, X-Ray Computed , Humans , Arthroplasty, Replacement, Hip/methods , Robotic Surgical Procedures/methods , Fluoroscopy/methods , Tomography, X-Ray Computed/methods , Female , Male , Middle Aged , Aged , Hip Prosthesis , Acetabulum/surgery , Acetabulum/diagnostic imaging , Surgery, Computer-Assisted/methods
2.
Sci Rep ; 14(1): 15458, 2024 07 04.
Article in English | MEDLINE | ID: mdl-38965266

ABSTRACT

In total hip arthroplasty (THA), determining the center of rotation (COR) and diameter of the hip joint (acetabulum and femoral head) is essential to restore patient biomechanics. This study investigates on-the-fly determination of hip COR and size, using off-the-shelf augmented reality (AR) hardware. An AR head-mounted device (HMD) was configured with inside-out infrared tracking enabling the determination of surface coordinates using a handheld stylus. Two investigators examined 10 prosthetic femoral heads and cups, and 10 human femurs. The HMD calculated the diameter and COR through sphere fitting. Results were compared to data obtained from either verified prosthetic geometry or post-hoc CT analysis. Repeated single-observer measurements showed a mean diameter error of 0.63 mm ± 0.48 mm for the prosthetic heads and 0.54 mm ± 0.39 mm for the cups. Inter-observer comparison yielded mean diameter errors of 0.28 mm ± 0.71 mm and 1.82 mm ± 1.42 mm for the heads and cups, respectively. Cadaver testing found a mean COR error of 3.09 mm ± 1.18 mm and a diameter error of 1.10 mm ± 0.90 mm. Intra- and inter-observer reliability averaged below 2 mm. AR-based surface mapping using HMD proved accurate and reliable in determining the diameter of THA components with promise in identifying COR and diameter of osteoarthritic femoral heads.


Subject(s)
Arthroplasty, Replacement, Hip , Augmented Reality , Femur Head , Hip Prosthesis , Humans , Femur Head/surgery , Femur Head/diagnostic imaging , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Tomography, X-Ray Computed , Rotation , Male , Hip Joint/surgery , Hip Joint/diagnostic imaging , Female
3.
J Orthop Surg Res ; 19(1): 385, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38951850

ABSTRACT

BACKGROUND: In recent years, the use of tapered-wedge short stems has increased due to their ability to preserve bones and tendons. Surgical techniques occasionally result in a varus position of the stem, which is particularly pronounced in short stems. Although the varus position is not clinically problematic, there are reports of an increased incidence of stress shielding and cortical hypertrophy. Thus, we evaluated and examined the acceptable range of varus angles using finite element analysis. METHODS: Patients diagnosed with osteoarthritis of the hip joint who had undergone arthroplasty were selected and classified into three types [champagne-flute (type A), intermediate (type B), and stovepipe (type C)]. Finite element analysis was performed using Mechanical Finder. The model was created using a Taperloc microplasty stem with the varus angle increased by 1° from 0° to 5° from the bone axis and classified into seven zones based on Gruen's zone classification under loading conditions in a one-leg standing position. The volume of interest was set, the mean equivalent stress for each zone was calculated. RESULTS: A significant decrease in stress was observed in zone 2, and increased stress was observed in zones 3 and 4, suggesting the emergence of a distal periosteal reaction, similar to the results of previous studies. In zone 2, there was a significant decrease in stress in all groups at a varus angle ≥ 3°. In zone 3, stress increased from ≥ 3° in type B and ≥ 4° in type C. In zone 4, there was a significant increase in stress at varus angles of ≥ 2° in types A and B and at ≥ 3° in type C. CONCLUSION: In zone 2, the varus angle at which stress shielding above Engh classification grade 3 may appear is expected to be ≥ 3°. Distal cortical hypertrophy may appear in zones 3 and 4; the narrower the medullary cavity shape, the smaller the allowable angle of internal recession, and the wider the medullary cavity shape, the wider the allowable range. Long-term follow-up is required in patients with varus angles > 3°.


Subject(s)
Arthroplasty, Replacement, Hip , Finite Element Analysis , Hip Prosthesis , Stress, Mechanical , Humans , Arthroplasty, Replacement, Hip/methods , Male , Female , Prosthesis Design , Aged , Osteoarthritis, Hip/surgery , Osteoarthritis, Hip/diagnostic imaging , Middle Aged
4.
BMC Musculoskelet Disord ; 25(1): 510, 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38961446

ABSTRACT

PURPOSE: Crowe IV developmental dysplasia of the hip (DDH) is a catastrophic hip disease. Moreover, obtaining ideal clinical efficacy in conventional total hip arthroplasty (THA) is often difficult. In this study, we aimed to assess the mid-term clinical results of THA with porous tantalum trabecular metal (TM) pads for acetabular reconstruction in the treatment of Crowe IV DDH. METHODS: A cohort of 28 patients (32 hips) diagnosed with Crowe type IV DDH who underwent acetabular reconstruction during THA using TM pads with scheduled follow-up between 2011 and 2018, were included in this study. Eight cases were men and 24 were women, with a mean age of 48.4 years (range, 36-72 years) and a mean follow-up was 74.3 months (range, 42-132 months). All patients underwent acetabular reconstruction using TM pads and total hip replacement with subtrochanteric osteotomy. RESULTS: At the final follow-up, 28 hips (87.5%) demonstrated mild or no postoperative limping. The Harris Hip Score improved from 58.4 ± 10.6 preoperatively to 85.6 ± 8.9. The mean pain, stiffness, and function scores on the Western Ontario and McMaster University Osteoarthritis index were 86.5 ± 10.2, 87.3 ± 12.4 and 85.4 ± 11.6 respectively. The mean score of patient satisfaction was 90.4 ± 7.6. Additionally, the SF-12 physical summary score was 41.8 ± 5.6 and the SF-12 mental summary score was 51.6 ± 5.4. TM construct survivorship due to all-cause failure was 90.6% at 5 years with 3 hips at risk, 87.5% at 10 years with 4 hips at risk. The survivorship due to failure from aseptic loosening was 96.9% at 5 years with 1hips at risk and 93.75% at 10 years with 2 hips at risk. CONCLUSION: This study demonstrated satisfactory mid-term clinical and radiological results with the application of TM pads for acetabular reconstruction combined with THA in patients with Crowe IV DDH. TRIAL REGISTRATION NUMBER: ChiCTR1800014526, Date: 18/01/2018.


Subject(s)
Arthroplasty, Replacement, Hip , Developmental Dysplasia of the Hip , Hip Prosthesis , Tantalum , Humans , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Middle Aged , Female , Male , Aged , Adult , Follow-Up Studies , Developmental Dysplasia of the Hip/surgery , Developmental Dysplasia of the Hip/diagnostic imaging , Treatment Outcome , Acetabulum/surgery , Acetabulum/diagnostic imaging , Prosthesis Design , Retrospective Studies , Porosity
6.
JBJS Case Connect ; 14(2)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38870321

ABSTRACT

CASE: A 70-year-old man with a year-long history of arthritic pain in his left hip presented to our clinic. He had a left intertrochanteric hip fracture 6 years ago, fixed with an open reduction internal fixation with a cephalomedullary nail. He underwent a conversion Birmingham Hip Resurfacing (BHR) with removal of the proximal helicoidal blade and retention of the intramedullary nail. At 7-year follow-up, the patient reported satisfactory clinical outcomes and excellent radiographic fixation. CONCLUSION: This case highlights using conversion BHR in patients with post-traumatic arthritis with retained femoral hardware as an alternative to conventional total hip arthroplasty.


Subject(s)
Arthroplasty, Replacement, Hip , Humans , Male , Aged , Arthroplasty, Replacement, Hip/instrumentation , Osteoarthritis, Hip/surgery , Hip Fractures/surgery , Hip Prosthesis
7.
Eur J Radiol ; 176: 111524, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38851014

ABSTRACT

PURPOSE: To assess the accuracy of 0.55 T MRI in diagnosing periprosthetic joint infection (PJI) in patients with symptomatic total hip arthroplasty (THA). MATERIAL AND METHODS: 0.55 T MRI of patients with THA PJI (Group A) and noninfected THA (Group B), including aseptic loosening (Group C, subgroup of B) performed between May 2021 and July 2023 were analysed retrospectively. Two musculoskeletal fellowship-trained radiologists independently identified MRI bone and soft tissue changes including: marrow oedema, periosteal reaction, osteolysis, joint effusion, capsule oedema and thickening, fluid collections, muscle oedema, bursitis, inguinal adenopathy, and muscle tears. The diagnostic performance of MRI discriminators of PJI was evaluated using Fisher's exact test (p < 0.05) and interrater reliability was determined. 61 MRI scans from 60 THA patients (34 female, median age 68, range 41-93 years) in Group A (n = 9; female 4; median age 69, range 56-82 years), B (n = 51; 30; 67.5, 41-93 years), and C (10; 6; 67; 41-82 years) were included. RESULTS: Capsule oedema (sensitivity 89 %, specificity 92 %,), intramuscular oedema (89 %, 82 %) and joint effusion (89 %, 73 %) were the best performing discriminators for PJI diagnosis (p ≤ 0.001), when viewed individually and had combined 70 % sensitivity and 100 % specificity for PJI diagnosis in parallel testing. For the differentiation between PJI and aseptic loosening, intramuscular oedema (89 %, 80 %) and capsule oedema (89 %, 80 %) were significant discriminators (p ≤ 0.001) with combined 64 % sensitivity and 96 % specificity for PJI. CONCLUSIONS: New generation 0.55 T MRI may aid in the detection of PJI in symptomatic patients. Oedema of the joint capsule, adjacent muscles as well as joint effusion were indicative of the presence of PJI.


Subject(s)
Magnetic Resonance Imaging , Prosthesis-Related Infections , Sensitivity and Specificity , Humans , Female , Male , Aged , Magnetic Resonance Imaging/methods , Prosthesis-Related Infections/diagnostic imaging , Middle Aged , Aged, 80 and over , Adult , Reproducibility of Results , Retrospective Studies , Arthroplasty, Replacement, Hip/adverse effects , Hip Prosthesis/adverse effects , Hip Joint/diagnostic imaging
8.
Tunis Med ; 102(6): 354-359, 2024 Jun 05.
Article in French | MEDLINE | ID: mdl-38864199

ABSTRACT

INTRODUCTION: The increase in hip arthroplasties predicts a rise in periprosthetic fractures in Morocco, posing challenges for orthopedic surgeons. Therapeutic strategies vary considerably, highlighting the absence of a universally accepted treatment protocol. AIM: To analyze the management of per-prosthetic hip fractures, while addressing the challenges associated with them. METHODS: This was a retrospective study, conducted in the trauma-orthopedics department between December 2015 and November 2022. Nineteen patients who presented to the hospital with fractures around a hip prosthesis were included. RESULT: Nineteen periprosthetic fractures were observed. The majority of patients (68%) were women, with an average age of 68. The Vancouver classification showed that 52.6% of the fractures were type B1, and 21.1% type C, while the other fracture types were distributed differently. These fractures were mainly associated with diagnoses such as femoral neck fracture (63.2%) and coxarthrosis (31.6%). We observed variations in treatment recommendations and results between the different series analyzed. We noted discrepancies with certain series concerning fracture types and therapeutic choices. However, in our series, we achieved satisfactory results, with successful consolidation and the absence of complications in all patients. CONCLUSION: These results underline the importance of an individualized approach to fracture management, taking into account the specificities of each case.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Fractures , Hospitals, University , Periprosthetic Fractures , Humans , Female , Retrospective Studies , Periprosthetic Fractures/epidemiology , Periprosthetic Fractures/therapy , Periprosthetic Fractures/surgery , Periprosthetic Fractures/etiology , Periprosthetic Fractures/diagnosis , Male , Morocco/epidemiology , Aged , Middle Aged , Arthroplasty, Replacement, Hip/statistics & numerical data , Arthroplasty, Replacement, Hip/methods , Hospitals, University/statistics & numerical data , Hip Fractures/epidemiology , Hip Fractures/surgery , Hip Fractures/therapy , Aged, 80 and over , Traumatology/standards , Traumatology/methods , Orthopedics/statistics & numerical data , Hip Prosthesis/statistics & numerical data , Adult
10.
Eur J Med Res ; 29(1): 314, 2024 Jun 08.
Article in English | MEDLINE | ID: mdl-38849967

ABSTRACT

Conventional radiography is regularly used to evaluate complications after total hip arthroplasty. In various recent consensus meetings, however, plain radiographs of a potentially infected hip joint have been judged as being only relevant to exclude diagnoses other than infection. Solid data on radiographic presentations of periprosthetic joint infection (PJI) are scarce. As a result, the prognostic value of radiological features in low-grade PJI remains uncertain. The present review article aims to present an overview of the available literature and to develop ideas on future perspectives to define the diagnostic possibilities of radiography in PJIs of the hip. The primary outcome of interest of this systematic review was the radiologic presentation of periprosthetic joint infections of the hip. As secondary outcome of interest served the sensitivity and specificity of the radiologic presentation of periprosthetic joint infections. Of the included articles, 26 were reviews, essays, or case reports and only 18 were clinical studies. Typical radiologic abnormalities of PJI were a periosteal reaction, a wide band of radiolucency at the cement-bone or metal-bone interface, patchy osteolysis, implant loosening, bone resorption around the implant, and transcortical sinus tracts. The frequency of their occurrence is still inadequately defined. A deeper understanding of the underlying causes and the relation between microorganisms to radiologic abnormalities can probably help clinicians in the future to diagnose a PJI. This is why further research shall focus on the radiographic features of PJI.


Subject(s)
Arthroplasty, Replacement, Hip , Prosthesis-Related Infections , Humans , Prosthesis-Related Infections/diagnostic imaging , Prognosis , Arthroplasty, Replacement, Hip/adverse effects , Radiography/methods , Hip Joint/diagnostic imaging , Hip Joint/pathology , Hip Prosthesis/adverse effects
11.
Orthop Surg ; 16(7): 1642-1647, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38837297

ABSTRACT

OBJECTIVE: Management of extensive acetabular bone defects in total hip arthroplasty (THA) remains challenging. This study aims to investigate the feasibility and preliminary outcomes of 3D-printed personalized porous acetabular components for the reconstruction of acetabular defects in primary THA. METHODS: This retrospective study involved seven patients who received 3D-printed acetabular components in primary THA between July 2018 and March 2021. Preoperatively, acetabular bone defects were evaluated by referencing the Paprosky classification. There were two "Paprosky type IIIA" defects and five "Paprosky type IIIB" defects. The acetabular components were custom-made for each patient to reconstruct the extensive acetabular defects. The hip function was assessed according to the Harris hip score (HHS). Clinical and radiographic outcomes were assessed. RESULTS: The average follow-up period was 40 months, ranging from 26 to 57 months. There were no patients lost to follow-up. The HHS improved from 44 (range: 33-53) before the operation to 88 (range: 79-93) at the final follow-up. Postoperative X-rays showed that the 3D-printed personalized components were properly fitted with the acetabulum. The average center of rotation (COR) discrepancy was 2.3 mm horizontally and 2.1 mm vertically, respectively. Tomosynthesis-Shimadzu metal artifact reduction technology images showed that the implant was in close contact with the host bone. Moreover, no complications were observed during the follow-up period, including loosening, dislocation, or component protrusion. CONCLUSION: The implantation of 3D-printed personalized acetabular components showed accurate reconstruction, stable mechanical support, and favorable function at short-term follow-up. This may be a viable alternative method for reconstructing extensive acetabular defects in THA.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip , Hip Prosthesis , Printing, Three-Dimensional , Prosthesis Design , Humans , Arthroplasty, Replacement, Hip/methods , Acetabulum/surgery , Retrospective Studies , Female , Male , Middle Aged , Aged , Adult , Porosity , Feasibility Studies
12.
J Vis Exp ; (206)2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38709053

ABSTRACT

Hip dysplasia causes major disability in dogs. Treatment options are limited to palliative treatment (e.g., pain relief, physical exercise, lifestyle changes, and weight control) or invasive surgeries such as pelvic osteotomies and total hip arthroplasty. Hence, a strong unmet need exists for an effective and dog-friendly solution that enhances the quality of life of man's best friend. We fill this treatment gap by offering a minimally traumatic and extraarticular, dog-specific, 3-dimensional-printed, hip implant (3DHIP) that restores hip joint stability. The surgical treatment using a 3DHIP implant is less invasive than osteotomies and can be performed bilaterally in one surgical session. The 3DHIP implant extends the dorsal acetabular rim of the dysplastic hip joint thereby increasing coverage of the femoral head and inhibiting joint subluxation with fast recovery. Sufficient access to the dorsal acetabular rim and ventral border of the iliac body together with optimal fitting and fixation of the implant are key steps for a successful 3DHIP implantation and imply the need for a specific approach. The present article aims to showcase this innovative surgical technique with tips and tricks as a surgical manual for implantation of the 3DHIP implant in dogs affected by hip dysplasia.


Subject(s)
Hip Dysplasia, Canine , Hip Prosthesis , Printing, Three-Dimensional , Dogs , Animals , Hip Dysplasia, Canine/surgery
17.
BMC Vet Res ; 20(1): 222, 2024 May 24.
Article in English | MEDLINE | ID: mdl-38783269

ABSTRACT

BACKGROUND: Biomedtrix BFX® cementless total hip replacement (THR) requires the use of femoral broaches to prepare a press-fit envelope within the femur for subsequent stem insertion. Current broaches contain teeth that crush and remove cancellous bone; however, they are not particularly well-suited for broaching sclerotic (corticalized) cancellous bone. In this study, three tooth designs [Control, TG1 (additional V-grooves), TG2 (diamond tooth pattern)] were evaluated with a quasi-static testing protocol and polyurethane test blocks simulating normal and sclerotic bone. To mimic clinical broaching, a series of five sequential broach insertions were used to determine cumulative broaching energy (J) and peak loads during broach insertion. To determine the effect of broach tooth design on THR stem insertion, a BFX® stem was inserted into prepared test blocks and insertion and subsidence energy and peak loads were determined. RESULTS: Broach tooth design led to significant differences in broaching energy and peak broaching loads in test blocks of both densities. In low density test blocks, TG1 required the lowest cumulative broaching energy (10.76 ±0.29 J), followed by Control (12.18 ±1.20 J) and TG2 (16.66 ±0.78 J) broaches. In high density test blocks, TG1 required the lowest cumulative broaching energy (32.60 ±2.54 J) as compared to Control (33.25 ±2.16 J) and TG2 (59.97 ±3.07 J).  During stem insertion and subsidence testing, stem insertion energy for high density test blocks prepared with Control broaches was 14.53 ± 0.81 J, which was significantly lower than blocks prepared with TG1 (22.53 ± 1.04 J) or TG2 (19.38 ± 3.00 J) broaches. For stem subsidence testing in high density blocks, TG1 prepared blocks required the highest amount of energy to undergo subsidence (14.49 ± 0.49 J), which was significantly greater than test blocks prepared with Control (11.09 ±0.09 J) or TG2 (12.57 ± 0.81 J) broaches. CONCLUSIONS: The additional V-grooves in TG1 broaches demonstrated improved broaching performance while also generating press-fit envelopes that were more resistant to stem insertion and subsidence. TG1 broaches may prove useful in the clinical setting; however additional studies that more closely simulate clinical broach impaction are necessary prior to making widespread changes to THR broaches.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Hip/veterinary , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Animals , Dogs/surgery , Hip Prosthesis/veterinary , Biomechanical Phenomena , Femur/surgery
18.
Arch Orthop Trauma Surg ; 144(6): 2831-2838, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38722364

ABSTRACT

INTRODUCTION: Cemented hemiarthroplasty (HA) is preferred in treating dislocated femoral neck fractures in elderly, osteoporotic patients, since uncemented HA was associated with mechanical complications more frequently. Cementation can conversely cause cardiopulmonary complications, leading to demand on safe, uncemented implants addressing osteoporosis. This study is set up as a retrospective feasibility study on the use of an uncemented, collared wedge implant (Actis®, DePuy Synthes, Warsaw, IN), for HA in elderly patients, focusing on complication rate. MATERIALS AND METHODS: From 1,194 patients, treated with HA in two study centers between 2017-2022, 188 received Actis® uncemented stem with bipolar head. Complete follow-up were retrospectively collected in all patients. RESULTS: In 188 patients (f: 64.9%; age: 83.1 ± 7.7a) included, no case of intra-operative mortality was recorded. 2 day mortality was 1.1%, 30 day mortality was 7.4% and 1 year mortality was 28.2%. 2 (1.1%) intra-operative fractures did not receive surgical revision, 3 (1.6%) post-operative periprosthetic fractures caused separate admission and revision. 2 cases (1.1%) of early infection required surgical revision. CONCLUSION: Our data provide proof of concept, that Actis® Stem allows an alternative, uncemented treatment option for displaced femoral neck fractures with HA. In case of preoperative or intraoperative medial cortical bone defects, stability of this implant is deteriorated.


Subject(s)
Femoral Neck Fractures , Hemiarthroplasty , Hip Prosthesis , Postoperative Complications , Humans , Femoral Neck Fractures/surgery , Femoral Neck Fractures/complications , Female , Male , Hemiarthroplasty/methods , Hemiarthroplasty/adverse effects , Retrospective Studies , Aged, 80 and over , Aged , Hip Prosthesis/adverse effects , Postoperative Complications/epidemiology , Feasibility Studies , Prosthesis Design , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/adverse effects
19.
Arch Orthop Trauma Surg ; 144(6): 2873-2879, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38762654

ABSTRACT

INTRODUCTION: Aseptic loosening and periprosthetic fractures are main reasons for revision after THA. Quite different from most other stem systems, Corail cementless hip stems show better survival rates than their cemented counterpart, which can possibly be explained by the use of a collar. The study aimed to investigate primary stability with standard and undersized hip stems both collared and collarless. MATERIALS AND METHODS: Primary stability of cementless, collared and collarless, femoral stems was measured in artificial bones using both undersized and standard size. After preconditioning, 3D micromotion was measured under cyclic loading at the bone-implant interface. RESULTS: The use of a collar resulted in higher micromotion within the same stem size but showed no statistically significant difference for both standard and undersized hip stems. The collared and collarless undersized stems showed no significant differences in 3D micromotion at the upper measuring positions compared to the standard stem size. Micromotion was significantly higher in the distal measuring positions, with and without collar, for the undersized stems (vs. standard collarless stem size). CONCLUSION: The key finding is that the collarless and collared Corail hip stems, within one stem size, showed no significant differences in primary stability. Undersized stems showed significantly higher micromotion in the distal area both with and without collar.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Prosthesis Design , Biomechanical Phenomena , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/instrumentation , Humans , Prosthesis Failure
20.
Arch Orthop Trauma Surg ; 144(6): 2865-2872, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38753013

ABSTRACT

INTRODUCTION: The accuracy of acetabular cup placement using conventional portable imageless navigation systems in total hip arthroplasty (THA) in the lateral decubitus position remains challenging. Several novel portable imageless navigation systems have been developed recently to improve cup placement accuracy in THA. This study compared the accuracy of acetabular cup placement using a conventional accelerometer-based portable navigation (c-APN) system and a novel accelerometer-based portable navigation (n-APN) system during THA in the lateral decubitus position. MATERIALS AND METHODS: This retrospective cohort study compared 45 THAs using the c-APN and 45 THAs using the n-APN system. The primary outcomes were the absolute errors between the intraoperative and postoperative values of acetabular cup radiographic inclination and anteversion angles and the percentage of cases with absolute errors within 5°. Intraoperative values were shown on navigation systems, and postoperative measurements were conducted using computed tomography images. RESULTS: The median absolute errors of the cup inclination angles were significantly smaller in the n-APN group than in the c-APN group (3.9° [interquartile range 2.2°-6.0°] versus 2.2° [interquartile range 1.0°-3.3°]; P = 0.002). Additionally, the median absolute errors of the cup anteversion angles were significantly smaller in the n-APN group than in the c-APN group (4.4° [interquartile range 2.4°-6.5°] versus 1.9° [interquartile range 0.8°-2.7°]; P < 0.001). Significant differences were observed in the percentage of cases with absolute errors within 5° of inclination (c-APN group 67% versus n-APN group 84%; P = 0.049) and anteversion angles (c-APN group 62% versus n-APN group 91%; P = 0.001). CONCLUSIONS: The n-APN system improved the accuracy of the cup placement compared to the c-APN system for THA in the lateral decubitus position.


Subject(s)
Accelerometry , Acetabulum , Arthroplasty, Replacement, Hip , Surgical Navigation Systems , Humans , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/instrumentation , Retrospective Studies , Acetabulum/surgery , Acetabulum/diagnostic imaging , Male , Female , Aged , Middle Aged , Accelerometry/methods , Accelerometry/instrumentation , Patient Positioning/methods , Surgery, Computer-Assisted/methods , Surgery, Computer-Assisted/instrumentation , Hip Prosthesis , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS