ABSTRACT
BACKGROUND: In vitro bioequivalence studies are strictly limited to the comparison of dissolution performance to a reference drug. These studies are performed without considering the chemical similarity between the generic and reference drug formulations. This work has focused on developing a groundbreaking method based on the laser-induced breakdown spectroscopy (LIBS) technique for the in vitro bioequivalence determination of immediate-release solid oral dosage form generic drugs and as an alternative method for establishing the biowaiver of in vivo generic drug studies. RESULTS: The novel LIBS-based methodology to determine in vitro bioequivalence is fast, easy to perform, and can be carried out without the requirement of tedious and complicated sample pre-treatment, nor expensive instrumentals and reagents, almost directly on the drug samples. Furthermore, the proposed methodology demonstrated that it is enough to identify the spectrochemical similarity of the formulation between generic drugs to a reference drug through the chemometric study of their LIBS spectra, based on the determination of the differentiation and similarity factors, f1 and f2, respectively, used in the pharmaceutical industry in this purpose. After analysing their LIBS spectra, the generic drugs selected for this work have all been shown to be in vitro bioequivalent, given their f1 values of less than 15 and f2 values greater than 50, according to the technical regulations on which the American and European medicines agencies are based for the approval of registration for generic immediate-release solid oral dosage form drugs. This has been evidenced even for drugs from Class III and Class IV of the biopharmaceutical classification system, whose active principle nominal concentration is very low as 0.1 and 0.25 mg/tablet, respectively. SIGNIFICANCE: for the first time the LIBS technique has been successfully used in an advanced application for the pharmaceutical industry. The proposed method constitutes a reliable and specialized methodology for the establishment of formulation similarity between two drugs, without the requirement of separate identification of each of their components, which is a new and potential tool to determine the in vitro bioequivalence for generic immediate-release solid oral dosage form drugs.
Subject(s)
Drugs, Generic , Lasers , Spectrum Analysis , Therapeutic Equivalency , Drugs, Generic/pharmacokinetics , Drugs, Generic/analysis , Spectrum Analysis/methodsABSTRACT
OBJECTIVE: To assess the effectiveness of the REFIX technology in the remineralization process of initial caries simulated on bovine enamel. The assessment involved the analysis of backscatter intensity, which was determined from laser speckle images. METHOD: Twenty-one bovine teeth were divided into three groups: G1 and G7 were submitted to treatment with the REFIX technology for 1 and 7 days, respectively. The control group was treated with deionized water. RESULTS: A significant difference in backscatter was found between the carious and sound areas in all groups (p = 0.0038, p < 0.0001, and p = 0.0002 for the control group, G1, and G7, respectively). The intergroup comparison revealed no significant difference among the groups studied. CONCLUSION: REFIX technology did not alter the optical properties of the samples of bovine teeth with simulated initial caries lesions after 1 and 7 days of treatment.
Subject(s)
Dental Caries , Dental Enamel , Lasers , Tooth Remineralization , Cattle , Animals , Dental Caries/diagnostic imaging , Dental Caries/therapy , Dental Enamel/drug effects , Dental Enamel/diagnostic imagingABSTRACT
Laser scribing is a promising technology for the rapid and large-scale production of low-cost electrochemical sensors from diverse substrates. Polyimide has been the most popular so far because of its low cost, flexibility and capability of generating high-quality porous graphene films, known as laser-induced graphene (LIG). Herein we report the electrochemistry of chloramphenicol (CAP) on LIG electrodes and its determination in honey samples. LIG electrodes were fabricated by the photothermal conversion of sp3 carbon within the polymeric matrix into sp2 carbon using a CO2 laser cutter. The LIG electrode associated with differential pulse voltammetry (DPV) showed good linearity (R2 > 0.99) in the range from 10 to 160 µmol L-1 with a limit of detection of 1.0 µmol L-1 and good precision (RSD < 5%) for the electrochemical reduction of CAP species. Detection was possible free from the interference of other antibiotics, such as amoxicillin, tetracycline, sulfanilamide, and sulfamethoxazole. Spiked honey samples were analyzed by the standard-addition method and recovery values between 86 and 109% were obtained, which confirmed the absence of sample matrix effects. Therefore, the proposed sensor is an alternative, feasible, low-cost, and powerful analytical tool for the determination of CAP in honey.
Subject(s)
Chloramphenicol , Electrochemical Techniques , Electrodes , Graphite , Honey , Honey/analysis , Graphite/chemistry , Chloramphenicol/analysis , Chloramphenicol/chemistry , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Lasers , Anti-Bacterial Agents/analysis , Anti-Bacterial Agents/chemistry , Limit of DetectionABSTRACT
In the current biopharmaceutical scenario, constant bioprocess monitoring is crucial for the quality and integrity of final products. Thus, process analytical techniques, such as those based on Raman spectroscopy, have been used as multiparameter tracking methods in pharma bioprocesses, which can be combined with chemometric tools, like Partial Least Squares (PLS) and Artificial Neural Networks (ANN). In some cases, applying spectra pre-processing techniques before modeling can improve the accuracy of chemometric model fittings to observed values. One of the biological applications of these techniques could have as a target the virus-like particles (VLP), a vaccine production platform for viral diseases. A disease that has drawn attention in recent years is Zika, with large-scale production sometimes challenging without an appropriate monitoring approach. This work aimed to define global models for Zika VLP upstream production monitoring with Raman considering different laser intensities (200 mW and 495 mW), sample clarification (with or without cells), spectra pre-processing approaches, and PLS and ANN modeling techniques. Six experiments were performed in a benchtop bioreactor to collect the Raman spectral and biochemical datasets for modeling calibration. The best models generated presented a mean absolute error and mean relative error respectively of 3.46 × 105 cell/mL and 35 % for viable cell density (Xv); 4.1 % and 5 % for cell viability (CV); 0.245 g/L and 3 % for glucose (Glc); 0.006 g/L and 18 % for lactate (Lac); 0.115 g/L and 26 % for glutamine (Gln); 0.132 g/L and 18 % for glutamate (Glu); 0.0029 g/L and 3 % for ammonium (NH4+); and 0.0103 g/L and 2 % for potassium (K+). Sample without conditioning (with cells) improved the models' adequacy, except for Glutamine. ANN better predicted CV, Gln, Glu, and K+, while Xv, Glc, Lac, and NH4+ presented no statistical difference between the chemometric tools. For most of the assessed experimental parameters, there was no statistical need for spectra pre-filtering, for which the models based on the raw spectra were selected as the best ones. Laser intensity impacts quality model predictions in some parameters, Xv, Gln, and K+ had a better performance with 200 mW of intensity (for PLS, ANN, and ANN, respectively), for CV the 495 mW laser intensity was better (for PLS), and for the other biochemical variables, the use of 200 or 495 mW did not impact model fitting adequacy.
Subject(s)
Spectrum Analysis, Raman , Zika Virus , Spectrum Analysis, Raman/methods , Bioreactors , Least-Squares Analysis , Neural Networks, Computer , Lasers , Humans , Zika Virus Infection/virology , AnimalsABSTRACT
In the quest to uncover biological cues that help explain organic changes brought on by an external stimulus, like stress, new technologies have become necessary. The Laser Speckle Contrast Analysis (LASCA) approach is one of these technologies that may be used to analyze biological data, including respiratory rate (RR) intervals, and then use the results to determine heart rate variability (HRV Thus, to evaluate the stress brought on by physical activity, this study used the LASCA approach. A stress induction procedure involving physical exertion was employed, and the results were compared to other established techniques (cortisol analysis and ECG signal) to verify the LASCA methodology as a tool for measuring HRV and stress. The study sample comprised 27 willing participants. The technique involving LASCA allowed for the non-invasive (non-contact) acquisition of HRV and the study of stress. Furthermore, it made it possible to gather pertinent data, such as recognizing modifications to the thermoregulation, peripheral vasomotor tonus, and renin-angiotensin-aldosterone systems that were brought on by elevated stress and, as a result, variations in HRV readings.
Subject(s)
Heart Rate , Stress, Physiological , Humans , Heart Rate/physiology , Pilot Projects , Male , Adult , Female , Stress, Physiological/physiology , Young Adult , Electrocardiography/methods , Lasers , Hydrocortisone , Respiratory Rate/physiologyABSTRACT
Advanced Oxidation Processes (AOPs) offer promising methods for disinfection by generating radical species like hydroxyl radicals, superoxide anion radicals, and hydroxy peroxyl, which can induce oxidative stress and deactivate bacterial cells. Photocatalysis, a subset of AOPs, activates a semiconductor using specific electromagnetic wavelengths. A novel material, Cu/Cu2O/CuO nanoparticles (NPs), was synthesized via a laser ablation protocol (using a 1064 nm wavelength laser with water as a solvent, with energy ranges of 25, 50, and 80 mJ for 10 min). The target was sintered from 100 °C to 800 °C at rates of 1.6, 1.1, and 1 °C/min. The composite phases of Cu, CuO, and Cu2O showed enhanced photocatalytic activity under visible-light excitation at 368 nm. The size of Cu/Cu2O/CuO NPs facilitates penetration into microorganisms, thereby improving the disinfection effect. This study contributes to synthesizing mixed copper oxides and exploring their activation as photocatalysts for cleaner surfaces. The electronic and electrochemical properties have potential applications in other fields, such as capacitor materials. The laser ablation method allowed for modification of the band gap absorption and enhancement of the catalytic properties in Cu/Cu2O/CuO NPs compared to precursors. The disinfection of E. coli with Cu/Cu2O/CuO systems serves as a case study demonstrating the methodology's versatility for various applications, including disinfection against different microorganisms, both Gram-positive and Gram-negative.
Subject(s)
Copper , Escherichia coli , Copper/chemistry , Escherichia coli/drug effects , Catalysis , Metal Nanoparticles/chemistry , Lasers , Oxidation-Reduction , Disinfection/methods , LightABSTRACT
The ivermectin (IVM), as a broad-spectrum antiparasitic drug, was widely prescribed to treat COVID-19 during the pandemic, despite lacking proven efficacy in combating this disease. Therefore, it is important to establish affordable devices in laboratories with minimal infrastructure. The laser engraving technology has been revolutionary in sensor manufacturing, primarily attributed to the diversity of substrates that can be employed and the freedom it provides in creating sensor models. In this work, electrochemical sensors based on graphene were developed using the laser engraving technology for IVM sensing. Through, the studies that used the techniques of cyclic voltammetry and differential pulse voltammetry, following parameter optimization, for the laser-induced graphene electrode demonstrated a mass transport governed by adsorption of the species and exhibited a linear working range of 10-100 (µmol L-1), a limit of detection (LOD) of 1.6 × 10-6 (mol L-1), a limit of quantification (LOQ) of 4.8 × 10-6 (mol L-1), and a sensitivity of 0.139 (µA µmol L-1). The developed method was successfully applied to direct analysis of pharmaceutical tablets, tap water (recovery of 94%) and synthetic urine samples (recovery between 97% and 113%). These results demonstrate the feasibility of the method for routine analyses involving environmental samples.
Subject(s)
Electrochemical Techniques , Graphite , Ivermectin , Lasers , Ivermectin/analysis , Ivermectin/chemistry , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Graphite/chemistry , Humans , Limit of Detection , Antiparasitic Agents/urine , Antiparasitic Agents/analysis , Antiparasitic Agents/chemistry , Electrodes , COVID-19 , SARS-CoV-2ABSTRACT
OBJECTIVES: To evaluate the potential of laser-microtextured abutments (LMAs) compared to machined abutments (MAs) in peri-implant clinical and radiographic outcomes. MATERIALS AND METHODS: Eligible studies consisted of randomized clinical trials (RCTs) retrieved from MEDLINE, Web of Science, Scopus, and Embase databases. The study adhered to the PRISMA statement, and the protocol was registered at the PROSPERO (registration number CRD42023443112). The risk of bias was evaluated according to version 2 of the Cochrane risk of bias tool (RoB 2). Meta-analyses were performed using random effect models. Afterward, the GRADE approach was used to determine the certainty of evidence. RESULTS: Four RCTs were included from a total of 2,876 studies. LMAs had lower peri-implant sulcus depth at 6-8 weeks (WMD: -0.69 mm; 95% CI: -0.97, -0.40; p = 0.15, I2 = 53%) and at one year (WMD: -0.75 mm; 95% CI: -1.41, -0.09; p = 0.09, I2 = 65%), but the certainty of evidence was low. In addition, the marginal bone loss favored the LMAs group (WMD: -0.29 mm; 95% CI: -0.36, -0.21; p = 0.69, I2 = 0%) with moderate evidence. There were fewer sites with bleeding on probing in the LMAs group (WMD: -1.10; 95% CI: -1.43, -0.77; p = 0.88, i2 = 0%). There was no statistical difference between groups for the modified gingival index and modified plaque index. Furthermore, all studies were classified as having some concerns risk of bias. CONCLUSIONS: There was low to moderate certainty evidence that LMAs can favor peri-implant clinical and radiographic parameters compared to MAs. CLINICAL RELEVANCE: Laser-microtextured abutments may benefit peri-implant clinical and radiographic outcomes.
Subject(s)
Dental Abutments , Lasers , Humans , Dental Implant-Abutment Design , Randomized Controlled Trials as TopicABSTRACT
OBJECTIVE: To evaluate the effect of the association of potassium iodide to antimicrobial photodynamic therapy on human carious dentin produced with a microcosm biofilm model. METHODS: A microcosm biofilm model was used to generate a caries lesion on human dentin. Pooled human saliva diluted with glycerol was used as an inoculum on specimens immersed on McBain artificial saliva enriched with 1 % sucrose (24 h at 37 °C in 5 % CO2). After refreshing culture media for 7 days, the dentin specimens were divided in 5 groups (3 specimens per group, in triplicate; n = 9): C (NaCl 0.9 %), CX (2 % chlorhexidine), PKI (0.01 % methylene blue photosensitizer+50 mM KI), L (laser at 15 J, 180 s, 22.7 J/cm2), and PKIL (methylene blue + KI + Laser). After the treatments, dentin was collected, and a 10-fold serial dilution was performed. The number of total microorganisms, total lactobacilli, total streptococci, and Streptococcus mutans was analyzed by microbial counts (CFU/mL). After normality and homoscedasticity analysis, the Welch's ANOVA and Dunnett's tests were used for CFU. All tests used a 5 % significance level. RESULTS: CX and PKIL groups showed significant bacterial decontamination of dentin, compared to group C (p < 0.05) reaching reductions up to 3.8 log10 for CX for all microorganisms' groups and PKIL showed 0.93, 1.30, 1.45, and 1.22 log10 for total microorganisms, total lactobacilli, total streptococci, and S. mutans, respectively. CONCLUSION: aPDT mediated by the association of KI and methylene blue with red laser reduced the viability of microorganisms from carious dentin and could be a promising option for cavity decontamination.
Subject(s)
Biofilms , Dental Caries , Dentin , Methylene Blue , Photochemotherapy , Photosensitizing Agents , Potassium Iodide , Streptococcus mutans , Humans , Methylene Blue/pharmacology , Methylene Blue/therapeutic use , Photochemotherapy/methods , Dental Caries/microbiology , Dental Caries/drug therapy , Dental Caries/therapy , Dentin/microbiology , Dentin/drug effects , Potassium Iodide/pharmacology , Potassium Iodide/therapeutic use , Biofilms/drug effects , Streptococcus mutans/drug effects , Photosensitizing Agents/therapeutic use , Photosensitizing Agents/pharmacology , Saliva/microbiology , Lactobacillus/drug effects , Streptococcus/drug effects , Chlorhexidine/pharmacology , Chlorhexidine/therapeutic use , In Vitro Techniques , Colony Count, Microbial , Saliva, Artificial , LasersABSTRACT
A significant modification in photoinduced energy transfer in cancer cells is reported by the assistance of a dynamic modulation of the beam size of laser irradiation. Human lung epithelial cancer cells in monolayer form were studied. In contrast to the quantum and thermal ablation effect promoted by a standard focused Gaussian beam, a spatially modulated beam can caused around 15% of decrease in the ablation threshold and formation of a ring-shaped distribution of the photothermal transfer effect. Optical irradiation was conducted in A549 cells by a 532 nm single-beam emerging from a Nd:YVO4 system. Ablation effects derived from spatially modulated convergent waves were controlled by an electrically focus-tunable lens. The proposed chaotic behavior of the spatial modulation followed an Arneodo chaotic oscillator. Fractional dynamic thermal transport was analyzed in order to describe photoenergy in propagation through the samples. Immediate applications of chaos theory for developing phototechnology devices driving biological functions or phototherapy treatments can be considered.
Subject(s)
Lung Neoplasms , Nonlinear Dynamics , Humans , Lung Neoplasms/radiotherapy , Lung Neoplasms/pathology , A549 Cells , Lasers , Epithelial Cells/radiation effects , Epithelial Cells/metabolism , Laser Therapy/methods , Cell Line, TumorABSTRACT
Parallel laser photogrammetry (PLP), which consists of attaching two or three parallel laser beams at a known inter-beam distance to a camera, can be used to collect morphological measurements of organisms noninvasively. The lasers project onto the photo being taken, and because the inter-beam distance is known, they act as a scale for image analysis programs like ImageJ. Traditionally, this method has been used to measure larger morphological traits (e.g., limb length, crown-rump length) to serve as proxies for overall body size, whereas applications to smaller anatomical features remain limited. To that end, we used PLP to measure the testes of 18 free-living mantled howler monkeys (Alouatta palliata) at La Selva Biological Station, Costa Rica. We tested whether this method could reliably measure this relatively small and globular morphology, and whether it could detect differences among individuals. We tested reliability in three ways: within-photo (coefficient of variation [CV] = 4.7%), between-photo (CV = 5.5%), and interobserver (intraclass correlation = 0.92). We found an average volume of 36.2 cm3 and a range of 16.4-54.4 cm3, indicating variation in testes size between individuals. Furthermore, these sizes are consistent with a previous study that collected measurements by hand, suggesting that PLP is a useful method for making noninvasive measurements of testes.
Subject(s)
Alouatta , Lasers , Photogrammetry , Testis , Animals , Alouatta/anatomy & histology , Alouatta/physiology , Male , Testis/anatomy & histology , Photogrammetry/methods , Costa Rica , Reproducibility of ResultsABSTRACT
BACKGROUND AND OBJECTIVES: Laser ablation is increasingly used to treat atrial fibrillation (AF). However, atrioesophageal injury remains a potentially serious complication. While proactive esophageal cooling (PEC) reduces esophageal injury during radiofrequency ablation, the effects of PEC during laser ablation have not previously been determined. We aimed to evaluate the protective effects of PEC during laser ablation of AF by means of a theoretical study based on computer modeling. METHODS: Three-dimensional mathematical models were built for 20 different cases including a fragment of atrial wall (myocardium), epicardial fat (adipose tissue), connective tissue, and esophageal wall. The esophagus was considered with and without PEC. Laser-tissue interaction was modeled using Beer-Lambert's law, Pennes' Bioheat equation was used to compute the resultant heating, and the Arrhenius equation was used to estimate the fraction of tissue damage (FOD), assuming a threshold of 63% to assess induced necrosis. We modeled laser irradiation power of 8.5 W over 20 s. Thermal simulations extended up to 250 s to account for thermal latency. RESULTS: PEC significantly altered the temperature distribution around the cooling device, resulting in lower temperatures (around 22°C less in the esophagus and 9°C in the atrial wall) compared to the case without PEC. This thermal reduction translated into the absence of transmural lesions in the esophagus. The esophagus was thermally damaged only in the cases without PEC and with a distance equal to or shorter than 3.5 mm between the esophagus and endocardium (inner boundary of the atrial wall). Furthermore, PEC demonstrated minimal impact on the lesion created across the atrial wall, either in terms of maximum temperature or FOD. CONCLUSIONS: PEC reduces the potential for esophageal injury without degrading the intended cardiac lesions for a variety of different tissue thicknesses. Thermal latency may influence lesion formation during laser ablation and may play a part in any collateral damage.
Subject(s)
Atrial Fibrillation , Catheter Ablation , Laser Therapy , Humans , Esophagus/surgery , Esophagus/injuries , Esophagus/pathology , Heart Atria/surgery , Atrial Fibrillation/surgery , Lasers , Computers , Catheter Ablation/methodsABSTRACT
The complex nature and structure of biomolecules and nanoparticles and their interactions make it challenging to achieve a deeper understanding of the dynamics at the nano-bio interface of enzymes and plasmonic nanoparticles subjected to light excitation. In this study, circular dichroism (CD) and Raman spectroscopic experiments and molecular dynamics (MD) simulations were used to investigate the potential changes at the nano-bio interface upon plasmonic excitation. Our data showed that photothermal and thermal heating induced distinct changes in the secondary structure of a model nanobioconjugate composed of lipase fromCandida antarcticafraction B (CALB) and gold nanoparticles (AuNPs). The use of a green laser led to a substantial decrease in the α-helix content of the lipase from 66% to 13% and an increase in the ß-sheet content from 5% to 31% compared to the initial conformation of the nanobioconjugate. In contrast, the differences under similar thermal heating conditions were only 55% and 11%, respectively. This study revealed important differences related to the enzyme secondary structure, enzyme-nanoparticle interactions, and the stability of the enzyme catalytic triad (Ser105-Asp187-His224), influenced by the instantaneous local temperature increase generated from photothermal heating compared to the slower rate of thermal heating of the bulk. These results provide valuable insights into the interactions between biomolecules and plasmonic nanoparticles induced by photothermal heating, advancing plasmonic biocatalysis and related fields.
Subject(s)
Gold , Metal Nanoparticles , Gold/chemistry , Lipase , Metal Nanoparticles/chemistry , Light , LasersABSTRACT
OBJECTIVE: To determine whether intra-mucosal injection of injectable platelet-rich fibrin (i-PRF) can promote healing after Diode Laser Gingival Depigmentation (DLGD). METHODOLOGY: A total of 20 arch sites of hyperpigmented gingiva of 10 patients underwent DLGD. For each patient, two arch sites were randomly assigned for either intra-mucosal injection of i-PRF (G1-i-PRF) (n=10 sites) or no treatment (G2-Control): (n=10 sites). Wound Healing Score (WHS), patient satisfaction, and Pigmentation Index (DOPI) were measured at 1 week and 1 and 3 months postoperatively. Histological assessment of tissue specimens was performed at baseline and 1 week. RESULTS: The percentage change in WHS at 1 week was significantly higher in G1 (58.34±15.43) compared to G2 (37.50±11.79). At day 1, 50% of patients in G1 were pain free compared with 75% in G2, who had mild pain. Mean DOPI decreased significantly at 3 months in both groups (P-value <0.001), without significant differences between groups. G1 specimens showed significantly higher epithelial thickness (P-value <0.001), as well as a higher number of blood vessels and less percentage of inflammatory cells. CONCLUSIONS: i-PRF demonstrated better clinical and histological healing potential and less patient discomfort compared to sites without treatment after DLGD. Registered at https://clinicaltrials.gov/ as (NCT05283668).
Subject(s)
Gingiva , Platelet-Rich Fibrin , Humans , Gingiva/pathology , Wound Healing , Face , LasersABSTRACT
Aluminum in its Al3+ form is a metal that inhibits plant growth, especially in acidic soils (pH < 5.5). Rapid and accurate quantitative detection of Al3+ in agricultural soils is critical for the timely implementation of remediation strategies. However, detecting metal ions requires time-consuming preparation of samples, using expensive instrumentation and non-portable spectroscopic techniques. As an alternative, electrochemical sensors offer a cost-effective and minimally invasive approach for in situ quantification of metal ions. Here, we developed and validated an electrochemical sensor based on bismuth-modified laser-induced graphene (LIG) electrodes for Al3+ quantitative detection in a range relevant to agriculture (1-300 ppm). Our results show a linear Al3+ detection range of 1.07-300 ppm with a variation coefficient of 5.3%, even in the presence of other metal ions (Pb2+, Cd2+, and Cu2+). The sensor offers a limit of detection (LOD) of 0.34 ppm and a limit of quantification (LOQ) of 1.07 ppm. We compared its accuracy for soil samples with pH < 4.8 to within 89-98% of spectroscopic methods (ICP-OES) and potentiometric titration. This technology's portability, easy to use, and cost-effectiveness make it a promising candidate for in situ quantification and remediation of Al3+ in agricultural soils and other complex matrices.
Subject(s)
Graphite , Soil , Aluminum , Bismuth , Ions/chemistry , Lasers , Electrochemical TechniquesABSTRACT
Photobiomodulation (PBM) induced by non-ionizing radiations emitted from low-power lasers and light-emitting diodes (LEDs) has been used for various therapeutic purposes due to its molecular, cellular, and systemic effects. At the molecular level, experimental data have suggested that PBM modulates base excision repair (BER), which is responsible for restoring DNA damage. There is a relationship between the misfunction of the BER DNA repair pathway and the development of tumors, including breast cancer. However, the effects of PBM on cancer cells have been controversial. Breast cancer (BC) is the main public health problem in the world and is the most diagnosed type of cancer among women worldwide. Therefore, the evaluation of new strategies, such as PBM, could increase knowledge about BC and improve therapies against BC. Thus, this work aims to evaluate the effects of low-power red laser (658 nm) and blue LED (470 nm) on the mRNA levels from BER genes in human breast cancer cells. MCF-7 and MDA-MB-231 cells were irradiated with a low-power red laser (69 J cm-2, 0.77 W cm-2) and blue LED (482 J cm-2, 5.35 W cm-2), alone or in combination, and the relative mRNA levels of the APTX, PolB, and PCNA genes were assessed by reverse transcription-quantitative polymerase chain reaction. The results suggested that exposure to low-power red laser and blue LED decreased the mRNA levels from APTX, PolB, and PCNA genes in human breast cancer cells. Our research shows that photobiomodulation induced by low-power red laser and blue LED decreases the mRNA levels of repair genes from the base excision repair pathway in MCF-7 and MDA-MB-231 cells.
Subject(s)
Breast Neoplasms , Low-Level Light Therapy , Humans , Female , RNA, Messenger/genetics , RNA, Messenger/metabolism , Breast Neoplasms/genetics , Breast Neoplasms/radiotherapy , Proliferating Cell Nuclear Antigen/metabolism , Lasers , DNA Repair/genetics , Low-Level Light Therapy/methodsABSTRACT
Objective: Investigating the effect of different parameters of photobiomodulation (PBM) with low-power laser on multi-potent mesenchymal stem cells (MSCs) derived from adipose tissue in terms of proliferation and cell death. Methods: MSCs were submitted to PBM applications with combinations of the following physical parameters: control group (no intervention), wavelengths of 660 and 830 nm; energy of 0.5, 2, and 4 J; and power of 40 and 100 mW. MSC analysis was performed using MetaXpress® software at 24, 48, and 72 h. Results: Irradiation promoted a significant increase in cell proliferation (p < 0.05), with 830 nm laser, 100 mW, with energy of 0.5, 2, and 4 J in relation to the control group at all times. PBM with 660 nm, power of 40 mW, and energy of 0.5, 2, and 4 J produced greater cell death at 24 h compared with the control group. At the time of 72 h, there was no significant difference concerning cell death. Conclusions: According to the results found, we can conclude that both wavelengths were effective; however, the 830 nm laser was more effective in terms of cell proliferation compared with the 660 nm laser. The 660 nm wavelength showed a significant increase in cell death when compared with the 830 nm laser.
Subject(s)
Low-Level Light Therapy , Mesenchymal Stem Cells , Low-Level Light Therapy/methods , Cells, Cultured , Mesenchymal Stem Cells/physiology , Mesenchymal Stem Cells/radiation effects , Lasers , Adipose TissueABSTRACT
To evaluate the osteogenic potential of platelet-rich fibrin (PRF) and low-level laser therapy (LLLT) on human stem cells from the apical papilla (SCAP) we isolated, characterized, and then cultured in an osteogenic medium cells with PRF and/or LLLT (660 nm, 6 J/m2-irradiation). Osteogenic differentiation was assessed by bone nodule formation and expression of bone morphogenetic proteins (BMP-2 and BMP-4), whereas the molecular mechanisms were achieved by qRT-PCR and RNA-seq analysis. Statistical analysis was performed by ANOVA and Tukey's post hoc tests (p < 0.05* and p < 0.01**). Although PRF and LLLT increased bone nodule formation after 7 days and peaked at 21 days, the combination of PRF + LLLT led to the uppermost nodule formation. This was supported by increased levels of BMP-2 and -4 osteogenic proteins (p < 0.005). Furthermore, the PRF + LLLT relative expression of specific genes involved in osteogenesis, such as osteocalcin, was 2.4- (p = 0.03) and 28.3- (p = 0.001) fold higher compared to the PRF and LLLT groups, and osteopontin was 22.9- and 1.23-fold higher, respectively (p < 0.05), after 7 days of interaction. The transcriptomic profile revealed that the combination of PRF + LLLT induces MSX1, TGFB1, and SMAD1 expression, after 21 days of osteogenic differentiation conditions exposition. More studies are required to understand the complete cellular and molecular mechanisms of PRF plus LLLT on stem cells. Overall, we demonstrated for the first time that the combination of PRF and LLLT would be an excellent therapeutic tool that can be employed for dental, oral, and craniofacial repair and other tissue engineering applications.
Subject(s)
Osteogenesis , Platelet-Rich Fibrin , Humans , Platelet-Rich Fibrin/metabolism , Cell Proliferation , Cells, Cultured , Stem Cells , Cell Differentiation , LasersABSTRACT
Matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) based on micro/nanostructured materials with different natures has received increasing attention for the analysis of a wide variety of analytes. However, up to now, only a few studies have shown the application of simple platforms in MALDI-MS for the identification of intact proteins. The present work reports on the application of copper oxide particles (Cu2O PS), obtained by a greener route, in combination with low amounts of 2,5-dihydroxybenzoic acid (DHB) as a novel hybrid platform. The combined Cu2O PS@DHB matrix, containing only 2.5 mg mL-1 of particles and 10 mg mL-1 of DHB, was easily applicable in MALDI-MS without surface modification of target plates. Under optimal conditions, the analysis of intact proteins up to 150,000 Da was possible, including immunoglobulin G, bovine serum albumin, and cytochrome C with adequate spot-to-spot signal reproducibility (RSD < 10%). In addition, the analysis of glycopeptides from IgG digests was carried out to prove the multipurpose application of the Cu2O PS@DHB platform in the low m/z range (2500-3000 Da). From the obtained results, it can be concluded that the optical and surface properties of as-synthesized Cu2O PS are likely to be responsible for the superior performance of Cu2O PS@DHB in comparison with conventional matrices. In this sense, the proposed user-friendly methodology opens up the prospect for possible implementation in bioanalysis and diagnostic research.
Subject(s)
Copper , Glycopeptides , Hydroxybenzoates , Reproducibility of Results , Gentisates/chemistry , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Proteins/analysis , Lasers , OxidesABSTRACT
This study was dedicated to developing analytical methods for determining macronutrients (Ca, K, and Mg) in soy leaf samples with and without petioles. The study's primary purpose was to present Laser-induced breakdown spectroscopy (LIBS) as a viable alternative for directly analyzing leaf samples using chemometric tools to interpret the data obtained. The instrumental condition chosen for LIBS was 70â mJ of laser pulse energy, 1.0â µs of delay time, and 100â µm of spot size, which was applied to 896 samples: 305 of soy without petioles and 591 of soy with petioles. The reference values of the analytes for the proposition of calibration models were obtained using inductively coupled plasma optical emission spectroscopy (ICP-OES) technique. Twelve normalization modes and two calibration strategies were tested to minimize signal variations and sample matrix microheterogeneity. The following were studied: multivariate calibration using partial least squares and univariate calibration using the area and height of several selected emission lines. The notable normalization mode for most models was the Euclidean norm. No analyte showed promising results for univariate calibrations. Micronutrients, P and S, were also tested, and no multivariate models presented satisfactory results. The models obtained for Ca, K, and Mg showed good results. The standard error of calibration ranged from 2.3â g/kg for Ca in soy leaves without petioles with two latent variables to 5.0â g/kg for K in soy leaves with petioles with two latent variables.