1 - 20 de 7.377
1.
Biomed Microdevices ; 26(3): 28, 2024 Jun 03.
Article En | MEDLINE | ID: mdl-38825594

Microfluidic-based point-of-care diagnostics offer several unique advantages over existing bioanalytical solutions, such as automation, miniaturisation, and integration of sensors to rapidly detect on-site specific biomarkers. It is important to highlight that a microfluidic POC system needs to perform a number of steps, including sample preparation, nucleic acid extraction, amplification, and detection. Each of these stages involves mixing and elution to go from sample to result. To address these complex sample preparation procedures, a vast number of different approaches have been developed to solve the problem of reagent storage and delivery. However, to date, no universal method has been proposed that can be applied as a working solution for all cases. Herein, both current self-contained (stored within the chip) and off-chip (stored in a separate device and brought together at the point of use) are reviewed, and their merits and limitations are discussed. This review focuses on reagent storage devices that could be integrated with microfluidic devices, discussing further issues or merits of these storage solutions in two different sections: direct on-chip storage and external storage with their application devices. Furthermore, the different microvalves and micropumps are considered to provide guidelines for designing appropriate integrated microfluidic point-of-care devices.


Lab-On-A-Chip Devices , Point-of-Care Systems , Humans , Microfluidic Analytical Techniques/instrumentation , Indicators and Reagents/chemistry , Equipment Design
2.
Anal Chim Acta ; 1312: 342742, 2024 Jul 11.
Article En | MEDLINE | ID: mdl-38834261

Hyperuricemia (HUA) has gradually become a public health burden as an independent risk factor for a variety of chronic diseases. Herein, a user-friendly point-of-care (POC) detection system (namely "Smart-HUA-Monitor") based on smartphone-assisted paper-based microfluidic is proposed for colorimetric quantification of HUA urinary markers, including uric acid (UA), creatinine (CR) and pH. The detection limits of UA and CR were 0.0178 and 0.5983 mM, respectively, and the sensitivity of pH were 0.1. The method was successfully validated in artificial urine samples and 100 clinical samples. Bland-Altman plots showed a high consistency between µPAD and the testing instruments (HITACHI 7600 Automatic Analyzer, URIT-500B Urine Analyzer and AU5800B automatic biochemical analyzer) in hospital. Smart-HUA-Monitor provides an accurate quantitative, rapid, low-cost and reliable tool for the monitoring and early diagnosis of HUA urine indicators.


Colorimetry , Hyperuricemia , Paper , Polymers , Uric Acid , Humans , Hyperuricemia/diagnosis , Hyperuricemia/urine , Polymers/chemistry , Uric Acid/urine , Colorimetry/instrumentation , Lab-On-A-Chip Devices , Smartphone , Creatinine/urine , Microfluidic Analytical Techniques/instrumentation , Limit of Detection , Biomarkers/urine , Hydrogen-Ion Concentration
3.
Mikrochim Acta ; 191(6): 362, 2024 06 01.
Article En | MEDLINE | ID: mdl-38822867

Rapid and accurate in situ determination of dopamine is of great significance in the study of neurological diseases. In this work, poly (3,4-ethylenedioxythiophene): poly (styrenesulfonic acid) (PEDOT: PSS)/graphene oxide (GO) fibers were fabricated by an effective method based on microfluidic wet spinning technology. The composite microfibers with stratified and dense arrangement were continuously prepared by injecting PEDOT: PSS and GO dispersion solutions into a microfluidic chip. PEDOT: PSS/GO fiber microelectrodes with high electrochemical activity and enhanced electrochemical oxidation activity of dopamine were constructed by controlling the structure composition of the microfibers with varying flow rate. The fabricated fiber microelectrode had a low detection limit (4.56 nM) and wide detection range (0.01-8.0 µM) for dopamine detection with excellent stability, repeatability, and reproducibility. In addition, the PEDOT: PSS/GO fiber microelectrode prepared was successfully used for the detection of dopamine in human serum and PC12 cells. The strategy for the fabrication of multi-component fiber microelectrodes is a new and effective approach for monitoring the intercellular neurotransmitter dopamine and has high potential as an implantable neural microelectrode.


Dopamine , Graphite , Microelectrodes , Polystyrenes , PC12 Cells , Dopamine/blood , Humans , Rats , Animals , Polystyrenes/chemistry , Graphite/chemistry , Limit of Detection , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Bridged Bicyclo Compounds, Heterocyclic/chemistry , Thiophenes/chemistry , Lab-On-A-Chip Devices , Polymers
4.
PLoS One ; 19(5): e0295849, 2024.
Article En | MEDLINE | ID: mdl-38696491

INTRODUCTION: Microfluidic resistive pulse sensing (MRPS) can determine the concentration and size distribution of extracellular vesicles (EVs) by measuring the electrical resistance of single EVs passing through a pore. To ensure that the sample flows through the pore, the sample needs to contain a wetting agent, such as bovine serum albumin (BSA). BSA leaves EVs intact but occasionally results in unstable MRPS measurements. Here, we aim to find a new wetting agent by evaluating Poloxamer-188 and Tween-20. METHODS: An EV test sample was prepared using an outdated erythrocyte blood bank concentrate. The EV test sample was diluted in Dulbecco's phosphate-buffered saline (DPBS) or DPBS containing 0.10% BSA (w/v), 0.050% Poloxamer-188 (v/v) or 1.00% Tween-20 (v/v). The effect of the wetting agents on the concentration and size distribution of EVs was determined by flow cytometry. To evaluate the precision of sample volume determination with MRPS, the interquartile range (IQR) of the particles transit time through the pore was examined. To validate that DPBS containing Poloxamer-188 yields reliable MRPS measurements, the repeatability of MRPS in measuring blood plasma samples was examined. RESULTS: Flow cytometry results show that the size distribution of EVs in Tween 20, in contrast to Poloxamer-188, differs from the control measurements (DPBS and DPBS containing BSA). MRPS results show that Poloxamer-188 improves the precision of sample volume determination compared to BSA and Tween-20, because the IQR of the transit time of EVs in the test sample is 11 µs, which is lower than 56 µs for BSA and 16 µs for Tween-20. Furthermore, the IQR of the transit time of particles in blood samples with Poloxamer-188 are 14, 16, and 14 µs, which confirms the reliability of MRPS measurements. CONCLUSION: The solution of 0.050% Poloxamer-188 in DPBS does not lyse EVs and results in repeatable and unimpeded MRPS measurements.


Extracellular Vesicles , Poloxamer , Poloxamer/chemistry , Extracellular Vesicles/metabolism , Extracellular Vesicles/chemistry , Humans , Polysorbates/chemistry , Serum Albumin, Bovine/chemistry , Microfluidics/methods , Wettability , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Animals
5.
Biomed Microdevices ; 26(2): 24, 2024 May 06.
Article En | MEDLINE | ID: mdl-38709370

We report the fabrication and characterisation of magnetic liquid beads with a solid magnetic shell and liquid core using microfluidic techniques. The liquid beads consist of a fluorinated oil core and a polymer shell with magnetite particles. The beads are generated in a flow-focusing polydimethylsiloxane (PDMS) device and cured by photo polymerisation. We investigated the response of the liquid beads to an external magnetic field by characterising their motion towards a permanent magnet. Magnetic sorting of liquid beads in a channel was achieved with 90% efficiency. The results show that the liquid beads can be controlled magnetically and have potential applications in digital microfluidics including nucleic acid amplification, drug delivery, cell culture, sensing, and tissue engineering. The present paper also discusses the magnetophoretic behaviour of the liquid bead by varying its mass and magnetite concentration in the shell. We also demonstrated the two-dimensional self-assembly of magnetic liquid beads for potential use in digital polymerase chain reaction and digital loop mediated isothermal amplification.


Dimethylpolysiloxanes , Dimethylpolysiloxanes/chemistry , Microfluidic Analytical Techniques/instrumentation , Magnetic Fields , Microspheres
6.
Anal Chim Acta ; 1307: 342640, 2024 Jun 08.
Article En | MEDLINE | ID: mdl-38719417

BACKGROUND: The analysis of cell membrane permeability plays a crucial role in improving the procedures of cell cryopreservation, which will affect the specific parameter settings in loading, removal and cooling processes. However, existing studies have mostly focused on deriving permeability parameters through osmotic theoretical models and cell volume response analysis, and there is still a lack of the direct experimental evidence and analysis at the single-cell level regarding the migration of cryoprotectants. RESULTS: In this work, a side perfusion microfluidics chips combined with Raman spectroscopy system was built to monitor in situ the Raman spectroscopy of extracellular and intracellular solution during loading and elution process with different cryoprotectant solution systems (single and dual component). And it was found that loading a high concentration cryoprotectant solution system through a single elution cycle may result in significant residual protective agent, which can be mitigated by employing a multi-component formula but multiple elution operations are still necessary. Furthermore, the collected spectral signals were marked and analyzed to was perform preliminary relative quantitative analysis. The results showed that the intracellular concentration changes can be accurately quantified by the Raman spectrum and are closely related to the extracellular solution concentration changes. SIGNIFICANCE AND NOVELTY: By using the method of small flow perfusion (≤20 µL/min) in the side microfluidic chip after the gravity sedimentation of cells, the continuous loading and elution process of different cryoprotectants on chip and the spectral acquisition can be realized. The intracellular and extracellular concentrations can be quantified in situ based on the ratio of spectral peak intensities. These results indicate that spectroscopic analysis can be used to effectively monitor intracellular cryoprotectant residues.


Cryoprotective Agents , Single-Cell Analysis , Spectrum Analysis, Raman , Spectrum Analysis, Raman/methods , Cryoprotective Agents/chemistry , Cryoprotective Agents/pharmacology , Cryoprotective Agents/isolation & purification , Lab-On-A-Chip Devices , Humans , Microfluidic Analytical Techniques/instrumentation , Cryopreservation/methods , Animals
7.
Anal Chim Acta ; 1308: 342575, 2024 Jun 15.
Article En | MEDLINE | ID: mdl-38740448

BACKGROUND: Alzheimer's disease (AD) is a prevalent neurodegenerative disease with no effective treatment. Efficient and rapid detection plays a crucial role in mitigating and managing AD progression. Deep learning-assisted smartphone-based microfluidic paper analysis devices (µPADs) offer the advantages of low cost, good sensitivity, and rapid detection, providing a strategic pathway to address large-scale disease screening in resource-limited areas. However, existing smartphone-based detection platforms usually rely on large devices or cloud servers for data transfer and processing. Additionally, the implementation of automated colorimetric enzyme-linked immunoassay (c-ELISA) on µPADs can further facilitate the realization of smartphone µPADs platforms for efficient disease detection. RESULTS: This paper introduces a new deep learning-assisted offline smartphone platform for early AD screening, offering rapid disease detection in low-resource areas. The proposed platform features a simple mechanical rotating structure controlled by a smartphone, enabling fully automated c-ELISA on µPADs. Our platform successfully applied sandwich c-ELISA for detecting the ß-amyloid peptide 1-42 (Aß 1-42, a crucial AD biomarker) and demonstrated its efficacy in 38 artificial plasma samples (healthy: 19, unhealthy: 19, N = 6). Moreover, we employed the YOLOv5 deep learning model and achieved an impressive 97 % accuracy on a dataset of 1824 images, which is 10.16 % higher than the traditional method of curve-fitting results. The trained YOLOv5 model was seamlessly integrated into the smartphone using the NCNN (Tencent's Neural Network Inference Framework), enabling deep learning-assisted offline detection. A user-friendly smartphone application was developed to control the entire process, realizing a streamlined "samples in, answers out" approach. SIGNIFICANCE: This deep learning-assisted, low-cost, user-friendly, highly stable, and rapid-response automated offline smartphone-based detection platform represents a good advancement in point-of-care testing (POCT). Moreover, our platform provides a feasible approach for efficient AD detection by examining the level of Aß 1-42, particularly in areas with low resources and limited communication infrastructure.


Alzheimer Disease , Amyloid beta-Peptides , Biomarkers , Enzyme-Linked Immunosorbent Assay , Paper , Smartphone , Alzheimer Disease/diagnosis , Alzheimer Disease/blood , Humans , Biomarkers/blood , Biomarkers/analysis , Amyloid beta-Peptides/analysis , Amyloid beta-Peptides/blood , Peptide Fragments/blood , Peptide Fragments/analysis , Lab-On-A-Chip Devices , Deep Learning , Automation , Microfluidic Analytical Techniques/instrumentation
8.
Anal Chim Acta ; 1308: 342639, 2024 Jun 15.
Article En | MEDLINE | ID: mdl-38740452

BACKGROUND: Calcium and magnesium ions are highly abundant and important cations in human body. At the same time, both dyscalcemia and dysmagnesemia are frequently encountered in the clinical practice. As deficiency or excess of Ca(II) or Mg(II) can cause severe symptoms, determining these ions in serum is of great importance. Concentration of these ions in biological samples is typically assayed in clinical laboratories with the use of expensive and specialized equipment. Since those methods cannot be easily adapted for self-diagnosis purposes, there is a great need to develop a convenient tool for reliable determination of calcium and magnesium in serum at the point-of-care. RESULTS: The colorimetric methods employed for calcium and magnesium analysis were o-cresophtalein complexone assay and xylidyl blue assay, respectively. Analytical signal acquisition was accomplished using an ordinary flatbed scanner or smartphone and free software. For increased user-friendliness the device was optimized to perform simultaneous determination of calcium and magnesium ions in only 10 min. In the optimized conditions, the limit of detection for calcium ions was 0.09 mmol L-1, while for magnesium it was 0.04 mmol L-1. Determination of both ions requires only 4 µL of serum sample. The developed paper-based sensors were validated with control human serum samples and the obtained relative errors for majority of samples were below 20 %. SIGNIFICANCE: In this paper, a microfluidic paper-based analytical device for simultaneous determination of calcium and magnesium ions in human serum is reported for the first time. Additionally, this is also the first report on colorimetric determination in serum of any of these ions in paper-based format. Simultaneous detection of both ions allows for fast and user-friendly screening of disturbance in calcium and magnesium homeostasis.


Calcium , Magnesium , Paper , Magnesium/blood , Humans , Calcium/blood , Colorimetry , Lab-On-A-Chip Devices , Microfluidic Analytical Techniques/instrumentation , Limit of Detection
9.
Methods Mol Biol ; 2804: 77-89, 2024.
Article En | MEDLINE | ID: mdl-38753141

Extracellular vesicles (EVs) are secreted by cells and found in biological fluids such as blood, with concentration correlated with oncogenic signals, making them attractive biomarkers for liquid biopsy. The current gold-standard method for EVs isolation requires an ultracentrifugation (UC) step among others. The cost and complexity of this technique are forbiddingly high for many researchers, as well as for routine use in biological laboratories and hospitals. This chapter reports on a simple microfluidic method for EVs isolation, based on a microfluidic size sorting technique named Deterministic Lateral Displacement (DLD). With the design of micrometric DLD array, we demonstrated the potential of our DLD devices for the isolation of nano-biological objects such as EVs, with main population size distribution consistent with UC technique.


Extracellular Vesicles , Lab-On-A-Chip Devices , Extracellular Vesicles/metabolism , Extracellular Vesicles/chemistry , Humans , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Cell Culture Techniques/methods , Ultracentrifugation/methods
10.
Methods Mol Biol ; 2804: 91-100, 2024.
Article En | MEDLINE | ID: mdl-38753142

Circulating tumor cells (CTCs) isolated directly from whole blood opens new perspectives for cancer monitoring and the development of personalized treatments. However, due to their rarity among the multitude of blood cells, it remains a challenge to recover them alive with high level of purity, i.e., with few remaining white blood cells, and in a time frame compatible with the clinical context. Microfluidic chips have emerged as promising tools to address these challenges. We propose a two-step workflow including a pre-enrichment step, performed by a size-based pre-enrichment system, and a purification step, performed by an immunomagnetic chip. Here, we describe the protocol for the fabrication of the immunomagnetic microchip, the preparation of the sample, and the procedure for injection into the microchip allowing the sorting of the CTCs.


Immunomagnetic Separation , Lab-On-A-Chip Devices , Neoplastic Cells, Circulating , Neoplastic Cells, Circulating/pathology , Immunomagnetic Separation/methods , Humans , Cell Separation/methods , Cell Separation/instrumentation , Neoplasms/pathology , Neoplasms/blood , Cell Line, Tumor , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods
11.
Methods Mol Biol ; 2804: 127-138, 2024.
Article En | MEDLINE | ID: mdl-38753145

Within the vast field of medical biotechnology, the biopharmaceutical industry is particularly fast-growing and highly competitive, so reducing time and costs associated to process optimization becomes instrumental to ensure speed to market and, consequently, profitability. The manufacturing of biopharmaceutical products, namely, monoclonal antibodies (mAbs), relies mostly on mammalian cell culture processes, which are highly dynamic and, consequently, difficult to optimize. In this context, there is currently an unmet need of analytical methods that can be integrated at-line in a bioreactor, for systematic monitoring and quantification of key metabolites and proteins. Microfluidic-based assays have been extensively and successfully applied in the field of molecular diagnostics; however, this technology remains largely unexplored for Process Analytical Technology (PAT), despite holding great potential for the at-line measurement of different analytes in bioreactor processes, combining low reagent/molecule consumption with assay sensitivity and rapid turnaround times.Here, the fabrication and handling of a microfluidic cartridge for protein quantification using bead-based affinity assays is described. The device allows geometrical multiplexed immunodetection of specific protein analytes directly from bioreactor samples within 2.5 h and minimal hands-on time. As a proof-of-concept, quantification of Chinese hamster ovary (CHO) host cell proteins (HCP) as key impurities, IgG as product of interest, and lactate dehydrogenase (LDH) as cell viability marker was demonstrated with limits of detection (LoD) in the low ng/mL range. Negligible matrix interference and no cross-reactivity between the different immunoassays on chip were found. The results highlight the potential of the miniaturized analytical method for PAT at reduced cost and complexity in comparison with sophisticated instruments that are currently the state-of-the-art in this context.


Cricetulus , CHO Cells , Animals , Antibodies, Monoclonal/immunology , Bioreactors , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Immunoassay/methods , Immunoassay/instrumentation , Microfluidics/methods , Microfluidics/instrumentation , Cricetinae
12.
Methods Mol Biol ; 2804: 65-75, 2024.
Article En | MEDLINE | ID: mdl-38753140

In recent years, the analysis of circulating cell-free DNA (cfDNA) containing tumor-derived DNA has emerged as a noninvasive means for cancer monitoring and personalized medicine. However, the isolation of cfDNA from peripheral blood has remained a challenge due to the low abundance and high fragmentation of these molecules. Here, we present a dynamic Magnetic ExTRactiOn (METRO) protocol using microfluidic fluidized bed technology to isolate circulating cfDNA from raw biological materials such as undiluted serum. This protocol maximizes the surface area for DNA binding within the chip in order to capture short DNA fragments. It uses only a few µL of sample and reagents. The protocol can be automated, and it is fully compatible with sensitive DNA amplification methods such as droplet-based digital PCR (ddPCR).


Cell-Free Nucleic Acids , Lab-On-A-Chip Devices , Humans , Cell-Free Nucleic Acids/isolation & purification , Cell-Free Nucleic Acids/blood , Cell-Free Nucleic Acids/genetics , Polymerase Chain Reaction/methods , Microfluidic Analytical Techniques/methods , Microfluidic Analytical Techniques/instrumentation , Magnetics/methods , Neoplasms/blood , Neoplasms/genetics , Neoplasms/diagnosis
13.
Methods Mol Biol ; 2804: 141-162, 2024.
Article En | MEDLINE | ID: mdl-38753146

Protein secretion is a key cellular functionality, particularly in immunology, where cells can display large heterogeneity in this crucial activity in addition to binary secretion behavior. However, few methods enable quantitative secretion rate measurements at the single-cell level, and these methods are mostly based on microfluidics systems. Here, we describe such a microfluidic single-cell method for precisely measuring protein secretion rates in detail, building on the published droplet-based microfluidic platform DropMap. We give an updated, detailed guide toward quantifying protein secretion rates, discussing its setup and limitations. We illustrate the protocol on two key immunological analytes, immunoglobulin G, and interferon-γ.


Interferon-gamma , Single-Cell Analysis , Single-Cell Analysis/methods , Humans , Interferon-gamma/metabolism , Immunoglobulin G/metabolism , Proteins/metabolism , Microfluidic Analytical Techniques/methods , Microfluidic Analytical Techniques/instrumentation , Microfluidics/methods , Microfluidics/instrumentation
14.
Methods Mol Biol ; 2804: 103-115, 2024.
Article En | MEDLINE | ID: mdl-38753143

In this chapter, we present the design and fabrication of a device and implementation of a protocol to realize increased efficiency of immunoassays within microtiter plates. The device, WellProbe, is a 3D-structured probe that can be used to deliver precise flows at the bottom of standard well plates to establish concentric areas of shear stress intensities using hydrodynamically confined flows. The protocols involve both operation and data analysis.


Equipment Design , Immunoassay/methods , Immunoassay/instrumentation , Hydrodynamics , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Humans
15.
Methods Mol Biol ; 2804: 179-194, 2024.
Article En | MEDLINE | ID: mdl-38753148

Antibiotic susceptibility testing (AST) is a routine procedure in diagnostic laboratories to determine pathogen resistance profiles toward antibiotics. The need for fast and accurate resistance results is rapidly increasing with a global rise in pathogen antibiotic resistance over the past years. Microfluidic technologies can enable AST with lower volumes, lower cell numbers, and a reduction in the sample-to-result time compared to state-of-the-art systems. We present a protocol to perform AST on a miniaturized nanoliter chamber array platform. The chambers are filled with antibiotic compounds and oxygen-sensing nanoprobes that serve as a viability indicator. The growth of bacterial cells in the presence of different concentrations of antibiotics is monitored; living cells consume oxygen, which can be observed as an increase of a luminesce signal within the growth chambers. Here, we demonstrate the technique using a quality control Escherichia coli strain, ATCC 35218. The AST requires 20 µL of a diluted bacterial suspension (OD600 = 0.02) and provides resistance profiles about 2-3 h after the inoculation. The microfluidic method can be adapted to other aerobic pathogens and is of particular interest for slow-growing strains.


Anti-Bacterial Agents , Escherichia coli , Microbial Sensitivity Tests , Microbial Sensitivity Tests/methods , Microbial Sensitivity Tests/instrumentation , Anti-Bacterial Agents/pharmacology , Escherichia coli/drug effects , Escherichia coli/growth & development , Escherichia coli/metabolism , Oxygen Consumption/drug effects , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Oxygen/metabolism , Lab-On-A-Chip Devices
16.
Methods Mol Biol ; 2804: 223-235, 2024.
Article En | MEDLINE | ID: mdl-38753151

Reliable predictions for the route and accumulation of nanotherapeutics in vivo are limited by the huge gap between the 2D in vitro assays used for drug screening and the 3D physiological in vivo environment. While developing a standard 3D in vitro model for screening nanotherapeutics remains challenging, multi-cellular tumor spheroids (MCTS) are a promising in vitro model for such screening. Here, we present a straightforward and flexible 3D-model microsystem made out of agarose-based micro-wells, which enables the formation of hundreds of reproducible spheroids in a single pipetting. Immunostaining and fluorescent imaging, including live high-resolution optical microscopy, can be done in situ without manipulating spheroids.


Hydrogels , Nanoparticles , Spheroids, Cellular , Humans , Nanoparticles/chemistry , Hydrogels/chemistry , Cell Line, Tumor , Microfluidics/methods , Microfluidics/instrumentation , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Microscopy, Fluorescence/methods
17.
Methods Mol Biol ; 2804: 163-176, 2024.
Article En | MEDLINE | ID: mdl-38753147

Multiomics studies at single-cell level require small volume manipulation, high throughput analysis, and multiplexed detection, characteristics that droplet microfluidics can tackle. However, the initial step of molecule bioseparation remains challenging. Here, we describe a unique magnetic device to trap and extract magnetic particles in sub-nanoliter droplets, for compartmentalisation of detection steps. Relying on electrodeposition of NiFe structures and microfluidic manipulation, the extraction of 1 µm diameter magnetic particles was achieved at high throughput (20 droplets per second) with an efficiency close to 100% in 450 pL droplets. The first demonstration of its adaptability to single-cell analysis is demonstrated with the extraction of mRNA. Using a purified nucleic acid solution, this unique magnetic configuration was able to reach a RNA extraction rate of 72%. This is the first demonstration of a physical separation in droplets at high throughput at single-cell scale.


Single-Cell Analysis , Single-Cell Analysis/methods , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , High-Throughput Screening Assays/methods , Magnetics/methods , RNA, Messenger/genetics , RNA, Messenger/isolation & purification , Humans , Microfluidics/methods , Microfluidics/instrumentation
18.
Methods Mol Biol ; 2804: 237-251, 2024.
Article En | MEDLINE | ID: mdl-38753152

Organ-on-a-chip technology allows researchers to precisely monitor drug efficacy in 3D tissue culture systems that are physiologically more relevant to humans compared to 2D cultures and that allow better control over experimental conditions as compared to animal models. Specifically, the high control over microenvironmental conditions combined with the broad range of direct measurements that can be performed in these systems makes organ-on-a-chip devices a versatile tool to investigate tumor targeting and drug delivery. Here, we describe a detailed protocol for studying the cell-selective targeting of protein drugs to tumor cells on an organ-on-a-chip system using a co-culture consisting of BT-474 cancer cells and C5120 human fibroblasts as an example.


Coculture Techniques , Lab-On-A-Chip Devices , Humans , Coculture Techniques/methods , Cell Line, Tumor , Fibroblasts/metabolism , Tumor Microenvironment , Neoplasms/pathology , Neoplasms/drug therapy , Drug Delivery Systems/methods , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Antineoplastic Agents/pharmacology , Microfluidics/methods , Microfluidics/instrumentation
19.
Methods Mol Biol ; 2804: 209-221, 2024.
Article En | MEDLINE | ID: mdl-38753150

Microfluidic-based cytotoxic assays provide high physiological relevance with the potential to replace conventional animal experiments and two-dimensional (2D) assays. Here, a 3D method utilizing a microfluidic platform for analysis of lymphocyte cytotoxicity is introduced in detail, including platform design, cell culture method, real-time cytotoxic assay setup, and image-based analysis. A 2D experimental method is used for comparison, which effectively demonstrates the advantages of 3D microfluidic platforms in closely recapitulating immune responses within the tumor microenvironment. Moreover, a wide range of experimental possibilities and applications using microfluidic 3D cytotoxic assays is introduced in this chapter, along with their capabilities, limitations, and future outlook.


Microfluidic Analytical Techniques , Humans , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Cell Culture Techniques/methods , Cell Culture Techniques/instrumentation , Cytotoxicity Tests, Immunologic/methods , Microfluidics/methods , Microfluidics/instrumentation , Animals , Lymphocytes/immunology , Lymphocytes/cytology , Tumor Microenvironment/immunology
20.
Biosens Bioelectron ; 258: 116337, 2024 Aug 15.
Article En | MEDLINE | ID: mdl-38703495

Recruiting circulating cells based on interactions between surface receptors and corresponding ligands holds promise for capturing cells with specific adhesive properties. Our study investigates the adhesion of skin cells to specific lectins, particularly focusing on advancements in lectin-based biosensors with diagnostic potential. We explore whether we can successfully capture normal skin (melanocytes and keratinocytes) and melanoma (WM35, WM115, WM266-4) cells in a low-shear flow environment by coating surfaces with lectins. Specifically, we coated surfaces with Dolichos biflorus (DBA) and Maackia Amurensis (MAL) lectins, which were used to detect and capture specific skin cells from the flow of cell mixture. Alterations in glycan expression (confirmed by fluorescent microscopy) demonstrated that DBA binds predominantly to normal skin cells, while MAL interacts strongly with melanoma cells. Assessing adhesion under static and dynamic low-shear stress conditions (up to 30 mPa) underscores the reliability of DBA and MAL as markers for discriminating specific cell type. Melanocytes and keratinocytes adhere to DBA-coated surfaces, while melanoma cells prefer MAL-coated surfaces. A comprehensive analysis encompassing cell shape, cytoskeleton, and focal adhesions shows the independence of our approach from the inherent characteristics of cells, thus demonstrating its robustness. Our results carry practical implications for lectin-biosensor designs, emphasizing the significance of glycan-based discrimination of pathologically altered cells. Combined with microfluidics, it demonstrates the value of cell adhesion as a discriminant of cancer-related changes, with potential applications spanning diagnostics, therapeutic interventions, and advanced biomedical technologies.


Biosensing Techniques , Cell Adhesion , Skin Neoplasms , Humans , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Glycosylation , Skin Neoplasms/pathology , Melanoma/pathology , Melanoma/diagnosis , Keratinocytes/cytology , Skin/pathology , Skin/chemistry , Lectins/chemistry , Lectins/metabolism , Cell Line, Tumor , Melanocytes/cytology , Melanocytes/metabolism , Microfluidics/methods , Microfluidic Analytical Techniques/instrumentation
...