1 - 20 de 7.591
1.
Molecules ; 29(11)2024 May 29.
Article En | MEDLINE | ID: mdl-38893435

This work describes the development of a reusable 2D detector based on radiochromic reaction for radiotherapy dosimetric measurements. It consists of a radiochromic gel dosimeter in a cuboidal plastic container, scanning with a flatbed scanner, and data processing using a dedicated software package. This tool is assessed using the example of the application of the coincidence test of radiation and mechanical isocenters for a medical accelerator. The following were examined: scanning repeatability and image homogeneity, the impact of image processing on data processing in coincidence tests, and irradiation conditions-monitor units per radiation beam and irradiation field are selected. Optimal conditions for carrying out the test are chosen: (i) the multi-leaf collimator gap should preferably be 5 mm for 2D star shot irradiation, (ii) it is recommended to apply ≥2500-≤5000 MU per beam to obtain a strong signal enabling easy data processing, (iii) Mean filter can be applied to the images to improve calculations. An approach to dosimeter reuse with the goal of reducing costs is presented; the number of reuses is related to the MUs per beam, which, in this study, is about 5-57 for 30,000-2500 MU per beam (four fields). The proposed reusable system was successfully applied to the coincidence tests, confirming its suitability as a new potential quality assurance tool in radiotherapy.


Radiation, Ionizing , Radiometry/methods , Radiometry/instrumentation , Gels/chemistry , Radiotherapy/methods , Radiotherapy Dosage , Radiation Dosimeters , Particle Accelerators
2.
Biomed Phys Eng Express ; 10(4)2024 Jun 20.
Article En | MEDLINE | ID: mdl-38861949

Laminated barriers incorporating metal sheets provide effective protection for space-restricted radiotherapy centers. This study aimed to assess photoneutron contamination in smaller vaults protected by different compositions of multilayer barriers during simulated pelvic radiotherapy with 18 MV photon beams. Monte Carlo Simulations of 18 MV LINAC (Varian 2100 C/D) and Medical Internal Radiation Dose (MIRD) phantom were used to assess photoneutron contamination within reconstructed vaults incorporating different combinations of metal sheet and borated polyethylene (BPE) during pelvic radiotherapy. The findings highlight a 3.27 and 2.91 times increase in ambient neutron doseHn*(10) along the maze of reconstructed vaults that use lead and steel sheets, respectively, compared to concrete. TheHn*(10) outside the treatment room increased after incorporating a metal sheet, but it remained within the permissible limit of 20µSv/week for uncontrolled areas adjacent to the LINAC bunker, even with a workload of 1000Gy/week. Neutron equivalent doses in the patient's organs ranged from 0.22 to 0.96 mSv Gy-1. There is no notable distinction in the organ's neutron equivalent dose, fatal cancer risk, secondary radiation-induced cancer risk, and cancer mortality for various laminated barrier compositions. Furthermore, the use of metal sheets for vault wall reconstruction keeps the variation in cancer risk induced by photoneutrons below 6%, while risks of fatal cancer and cancer mortality vary less than 11%. While the metal portion of the laminated barrier raises the neutron dose, the addition of a BPE plate reduces concerns of increased effective dose and secondary malignancy risk.


Monte Carlo Method , Neutrons , Phantoms, Imaging , Radiotherapy Dosage , Humans , Photons/therapeutic use , Particle Accelerators , Computer Simulation , Polyethylene/chemistry , Radiation Protection/methods , Radiation Dosage , Radiotherapy/methods
3.
Asian Pac J Cancer Prev ; 25(6): 2105-2112, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38918673

PURPOSE: The aim of this study was to investigate the detector size effect on small-field dosimetry and compare the performance of 6MV WFF/FFF techniques. METHODS: We investigated the detector size effect on small-field dosimetry and compared the performance of 6MV WFF/FFF techniques. PDD, profile curves, and absorbed dose were measured in water under reference conditions with 6MV (WFF/FFF) techniques. We employed Farmer FC65-P, CC13, CC01, and IBA Razor diode, with Versa Lineac. Subsequently, we replicated this assessment for small-fields under 5cmx5cm dimensions. RESULTS: For both 6MV WFF/FFF, significant dose differences (Dmax=1.47cm), were ±4.55%, ±6.7, ±12.75% and ±33.3% for 4cmx4cm, 3cmx3cm, 2cmx2cm, and 1cmx1cm, respectively. The average difference relative to D10 was observed to be ±4.66%, ±5.73%, ±6.58%, and ±8.75% for the previous field sizes. Differences between WFF/FFF are neglected values at all field sizes>2.3%, also, the output of the largest detector FC65-P is lower at 55% in the smallest field size. Variation in the profile doesn't exceed a difference of >5% in flatness between WFF/FFF at depth10cm, across all fields, while symmetry is >1%, but radiation output is considerably lower at 55% for FC65-P chamber in 2cmx2cm, 1cmx1cm compared to the CC01 chamber and Razor diode. Significant differences in 1cmx1cm, where FC65-P chamber exhibits around 49% difference compared to Razor diode with 6MV (WFF/FFF).  Conclusions: Significant differences were observed in doses with various detectors. Detector-size influences the dose. WFF/FFF techniques show no major differences in small-fields dosimetry. Utilize some situations the advantage of FFF boasting a higher dose rate, consequently reducing treatment time to half.


Radiometry , Humans , Radiometry/methods , Radiotherapy Dosage , Particle Accelerators/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Phantoms, Imaging
4.
Asian Pac J Cancer Prev ; 25(6): 2177-2184, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38918681

OBJECTIVE: The goal of this study is to determine the accuracy of the PTW Beamscan program in determining the inflection point from Flattening Filter Free Beam Profile utilizing Multiple Detectors. METHODS: True Beam Linear Accelerator with 6FFF and 10FFF Photon Energies and 10 cm, 15 cm and 20 cm Field Sizes were used for this study. Profile measurements were taken with PTW's 729, 1,500, and 1,600 and the Starcheck system, the Pinpoint 3D with Beamscan system, and Linac's EPID. The first-order derivative was utilized in both the Excel spreadsheet and Beamscan software to analyse raw measured data to locate inflection point and the FWHM was calculated. The accuracy of inflection points and FWHM between the Excel sheet calculation and the software program were investigated. RESULTS: For 10X10 cm2 in the 729 Array, the greatest differences in FWHM were 5.16 mm and 5.04 mm for the X6 FFF and X10 FFF Energies, respectively. The largest difference was 2.26 mm for 1,600 SRS arrays with a 15×15 cm2 field size. The difference in FWHM between Manual and software analysis for 10X10 cm2 and 20X20 cm2 Field Sizes is in decreasing order for detectors from 729, 1,500, 1,600 SRS, Starcheck, Pinpoint 3D, and EPID. In contrast, there is no climbing or declining pattern detected in the difference in Field Width for the 15×15 cm2 Field Size. Similarly, for all detectors except the 1,600 SRS array, the peak of the first-order derivative occurs at the chamber position for a 15X15 cm2 field size. CONCLUSION: The higher resolution of measurement yields more accuracy in inflection point and the FWHM. Irrespective of measurement resolution, the Beamscan software provided the FWHM closer to the respective nominal Field Size. Out of all detectors, results obtained with Excel Starcheck and EPID are good in agreement with values obtained by the software analysis. Thus, it is shown that Beamscan software is so accurate in determining inflection point of a FFF beam profile and used for routine profile analysis.


Particle Accelerators , Radiotherapy Planning, Computer-Assisted , Software , Particle Accelerators/instrumentation , Humans , Radiotherapy Planning, Computer-Assisted/methods , Photons , Radiotherapy Dosage , Radiometry/methods , Radiometry/instrumentation , Algorithms
5.
Opt Lett ; 49(9): 2425-2428, 2024 May 01.
Article En | MEDLINE | ID: mdl-38691735

Cherenkov imaging is an ideal tool for real-time in vivo verification of a radiation therapy dose. Given that radiation is pulsed from a medical linear accelerator (LINAC) together with weak Cherenkov emissions, time-gated high-sensitivity imaging is required for robust measurements. Instead of using an expensive camera system with limited efficiency of detection in each pixel, a single-pixel imaging (SPI) approach that maintains promising sensitivity over the entire spectral band could be used to provide a low-cost and viable alternative. A prototype SPI system was developed and demonstrated here in Cherenkov imaging of LINAC dose delivery to a water tank. Validation experiments were performed using four regular fields and an intensity-modulated radiotherapy (IMRT) delivery plan. The Cherenkov image-based projection percent depth dose curves (pPDDs) were compared to pPDDs simulated by the treatment planning system (TPS), with an overall average error of 0.48, 0.42, 0.65, and 1.08% for the 3, 5, 7, and 9 cm square beams, respectively. The composite image of the IMRT plan achieved a 85.9% pass rate using 3%/3 mm gamma index criteria, in comparing Cherenkov intensity and TPS dose. This study validates the feasibility of applying SPI to the Cherenkov imaging of radiotherapy dose for the first time to our knowledge.


Particle Accelerators , Time Factors , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Dosage
6.
Sci Rep ; 14(1): 10719, 2024 05 10.
Article En | MEDLINE | ID: mdl-38729975

The shielding parameters can vary depending on the geometrical structure of the linear accelerators (LINAC), treatment techniques, and beam energies. Recently, the introduction of O-ring type linear accelerators is increasing. The objective of this study is to evaluate the shielding parameters of new type of linac using a dedicated program developed by us named ORSE (O-ring type Radiation therapy equipment Shielding Evaluation). The shielding evaluation was conducted for a total of four treatment rooms including Elekta Unity, Varian Halcyon, and Accuray Tomotherapy. The developed program possesses the capability to calculate transmitted dose, maximum treatable patient capacity, and shielding wall thickness based on patient data. The doses were measured for five days using glass dosimeters to compare with the results of program. The IMRT factors and use factors obtained from patient data showed differences of up to 65.0% and 33.8%, respectively, compared to safety management report. The shielding evaluation conducted in each treatment room showed that the transmitted dose at every location was below 1% of the dose limit. The results of program and measurements showed a maximum difference of 0.003 mSv/week in transmitted dose. The ORSE program allows for the shielding evaluation results to the clinical environment of each institution based on patient data.


Particle Accelerators , Radiation Protection , Particle Accelerators/instrumentation , Radiation Protection/instrumentation , Radiation Protection/methods , Humans , Radiotherapy, Intensity-Modulated/methods , Radiation Dosage
7.
Biomed Phys Eng Express ; 10(4)2024 May 22.
Article En | MEDLINE | ID: mdl-38744248

Evaluating neutron output is important to ensure proper dose delivery for patients in boron neutron capture therapy (BNCT). It requires efficient quality assurance (QA) and quality control (QC) while maintaining measurement accuracy. This study investigated the optimal measurement conditions for QA/QC of activation measurements using a high-purity germanium (HP-Ge) detector in an accelerator-based boron neutron capture therapy (AB-BNCT) system employing a lithium target. The QA/QC uncertainty of the activation measurement was evaluated based on counts, reproducibility, and standard radiation source uncertainties. Measurements in a polymethyl methacrylate (PMMA) cylindrical phantom using aluminum-manganese (Al-Mn) foils and aluminum-gold (Al-Au) foils and measurements in a water phantom using gold wire with and without cadmium cover were performed to determine the optimal measurement conditions. The QA/QC uncertainties of the activation measurements were 4.5% for Au and 4.6% for Mn. The optimum irradiation proton charge and measurement time were determined to be 36 C and 900 s for measurements in a PMMA cylindrical phantom, 7.0 C and 900 s for gold wire measurements in a water phantom, and 54 C and 900 s at 0-2.2 cm depth and 3,600 s at deeper depths for gold wire measurements with cadmium cover. Our results serve as a reference for determining measurement conditions when performing QA/QC of activation measurements using HP-Ge detectors at an AB-BNCT employing a lithium target.


Boron Neutron Capture Therapy , Lithium , Particle Accelerators , Phantoms, Imaging , Quality Control , Lithium/chemistry , Boron Neutron Capture Therapy/methods , Humans , Particle Accelerators/instrumentation , Reproducibility of Results , Polymethyl Methacrylate/chemistry , Neutrons , Gold/chemistry , Aluminum/chemistry , Water/chemistry , Radiometry/methods , Radiometry/instrumentation , Radiotherapy Dosage
8.
Asian Pac J Cancer Prev ; 25(5): 1529-1538, 2024 May 01.
Article En | MEDLINE | ID: mdl-38809624

AIM: To evaluate the out-of-field dose associated with flattened (FF) and flattening filter-free (FFF) 6 and 10 MV X-ray beams in a TrueBeam linear accelerator (Linac). MATERIALS AND METHODS: Measurements were taken in a slab phantom using the metal oxide semiconductor field effect transistor (MOSFET) detector at varying depths (dmax, 5 cm, and 10 cm) for clinically relevant field sizes and up to 30 cm from the field edges for 6 and 10 MV FF and FFF beams in TrueBeam Linac. Dose calculation accuracy of the analytic anisotropic algorithm (AAA) and Acuros algorithm was investigated in the out-of-field region. Similarly, the out-of-field dose associated with volumetric modulated arc therapy (VMAT) head-and-neck plan delivered to a body phantom was evaluated. RESULTS: The out-of-field dose for both FF and FFF photon beams (6 and 10 MV) decreased with increasing distance from the field boundary and size. Furthermore, regardless of FF in the field, higher-energy photon beams were associated with lower out-of-field dose. Both algorithms underestimated the dose in the out-of-field region, with AAA failing to calculate the out-of-field dose at 15 cm from the field edge and Acuros failing to calculate out-of-field radiation at 20 cm. At 5 cm from the field edge, an average of 50% underestimation was observed, and at 10 cm, an average of 60% underestimation was observed for both FF and FFF (6 and 10 MV) beams. The VMAT head-and-neck plan performed with the FFF beam resulted in a lower out-of-field dose than the FF beam for a comparable dose distribution. CONCLUSION: Compared with flattened beams, the FFF modes on TrueBeam Linac exhibited a clinically relevant reduction in the out-of-field dose. Further dosimetric studies are warranted to determine the significant benefit of FFF beams across different cancer sites.


Algorithms , Particle Accelerators , Phantoms, Imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Particle Accelerators/instrumentation , Humans , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , X-Rays , Head and Neck Neoplasms/radiotherapy , Photons/therapeutic use
9.
Asian Pac J Cancer Prev ; 25(5): 1715-1723, 2024 May 01.
Article En | MEDLINE | ID: mdl-38809644

AIM: To assess the precision of dose calculations for Volumetric Modulated Arc Therapy (VMAT) using megavoltage (MV) photon beams, we validated the accuracy of two algorithms: AUROS XB and Analytical Anisotropic Algorithm (AAA). This validation will encompass both flattening filter (FF) and flattening filter-free beam (FFF) modes, using AAPM Medical Physics Practice Guideline (MPPG 5b). MATERIALS AND METHODS: VMAT validation tests were generated for 6 MV FF and 6 MV FFF beams using the AAA and AXB algorithms in the Eclipse V.15.1 treatment planning system (TPS). Corresponding measurements were performed on a linear accelerator using a diode detector and a radiation field analyzer. Point dose (PD) and in-vivo measurements were conducted using an A1SL ion chamber and (TLD) from Thermofisher, respectively. The Rando Phantom was employed for end-to-end (E2E) tests. RESULTS: The mean difference (MD) between the TPS-calculated values and the measured values for the PDD and output factors were within 1% and 0.5%, respectively, for both 6 MV FF and 6 MV FFF. In the TG 119 sets, the MD for PD with both AAA and AXB was <0.9%. For the TG 244 sets, the minimum, maximum, and mean deviations in PD for both 6 MV FF and 6 MV FFF beams were 0.3%, 1.4% and 0.8% respectively. In the E2E test, using the Rando Phantom, the MD between the TLD dose and the TPS dose was within 0.08% for both 6 MV FF (p=1.0) and 6 MV FFF (0.018) beams. CONCLUSION: The accuracy of the TPS and its algorithms (AAA and AXB) has been successfully validated. The recommended tests included in the VMAT/IMRT validation section proved invaluable for verifying the PDD, output factors, and the feasibility of complex clinical cases. E2E tests were instrumental in validating the entire workflow from CT simulation to treatment delivery.


Algorithms , Phantoms, Imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy, Intensity-Modulated/methods , Radiotherapy, Intensity-Modulated/standards , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Planning, Computer-Assisted/standards , Particle Accelerators , Practice Guidelines as Topic/standards , Radiometry/methods , Neoplasms/radiotherapy , Health Physics
10.
Sci Rep ; 14(1): 11253, 2024 05 16.
Article En | MEDLINE | ID: mdl-38755333

Accelerator-based boron neutron capture therapy (BNCT) systems employing a solid-state lithium target indicated the reduction of neutron flux over the lifetime of a target, and its reduction could represent the neutron flux model. This study proposes a novel compensatory approach for delivering the required neutron fluence and validates its clinical applicability. The proposed approach relies on the neutron flux model and the cumulative sum of real-time measurements of proton charges. The accuracy of delivering the required neutron fluence for BNCT using the proposed approach was examined in five Li targets. With the proposed approach, the required neutron fluence could be delivered within 3.0%, and within 1.0% in most cases. However, those without using the proposed approach exceeded 3.0% in some cases. The proposed approach can consider the neutron flux reduction adequately and decrease the effect of uncertainty in neutron measurements. Therefore, the proposed approach can improve the accuracy of delivering the required fluence for BNCT even if a neutron flux reduction is expected during treatment and over the lifetime of the Li target. Additionally, by adequately revising the approach, it may apply to other type of BNCT systems employing a Li target, furthering research in this direction.


Boron Neutron Capture Therapy , Lithium , Neutrons , Boron Neutron Capture Therapy/methods , Lithium/chemistry , Humans , Particle Accelerators , Radiotherapy Dosage
11.
Sci Rep ; 14(1): 11120, 2024 05 15.
Article En | MEDLINE | ID: mdl-38750131

Very High Energy Electron (VHEE) beams are a promising alternative to conventional radiotherapy due to their highly penetrating nature and their applicability as a modality for FLASH (ultra-high dose-rate) radiotherapy. The dose distributions due to VHEE need to be optimised; one option is through the use of quadrupole magnets to focus the beam, reducing the dose to healthy tissue and allowing for targeted dose delivery at conventional or FLASH dose-rates. This paper presents an in depth exploration of the focusing achievable at the current CLEAR (CERN Linear Electron Accelerator for Research) facility, for beam energies >200 MeV. A shorter, more optimal quadrupole setup was also investigated using the TOPAS code in Monte Carlo simulations, with dimensions and beam parameters more appropriate to a clinical situation. This work provides insight into how a focused VHEE radiotherapy beam delivery system might be achieved.


Electrons , Monte Carlo Method , Radiotherapy Dosage , Humans , Particle Accelerators/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy/methods , Radiotherapy, High-Energy/methods , Radiotherapy, High-Energy/instrumentation
12.
Sci Rep ; 14(1): 10957, 2024 05 13.
Article En | MEDLINE | ID: mdl-38740830

Very high energy electrons (VHEE) are a potential candidate for radiotherapy applications. This includes tumours in inhomogeneous regions such as lung and prostate cancers, due to the insensitivity of VHEE to inhomogeneities. This study explores how electrons in the VHEE range can be used to perform successful in vitro radiobiological studies. The ARES (accelerator research experiment at SINBAD) facility at DESY, Hamburg, Germany was used to deliver 154 MeV electrons to both prostate (PC3) and lung (A549) cancer cells in suspension. Dose was delivered to samples with repeatability and uniformity, quantified with Gafchromic film. Cell survival in response to VHEE was measured using the clonogenic assay to determine the biological effectiveness of VHEE in cancer cells for the first time using this method. Equivalent experiments were performed using 300 kVp X-rays, to enable VHEE irradiated cells to be compared with conventional photons. VHEE irradiated cancer cell survival was fitted to the linear quadratic (LQ) model (R2 = 0.96-0.97). The damage from VHEE and X-ray irradiated cells at doses between 1.41 and 6.33 Gy are comparable, suggesting similar relative biological effectiveness (RBE) between the two modalities. This suggests VHEE is as damaging as photon radiotherapy and therefore could be used to successfully damage cancer cells during radiotherapy. The RBE of VHEE was quantified as the relative doses required for 50% (D0.5) and 10% (D0.1) cell survival. Using these values, VHEE RBE was measured as 0.93 (D0.5) and 0.99 (D0.1) for A549 and 0.74 (D0.5) and 0.93 (D0.1) for PC3 cell lines respectively. For the first time, this study has shown that 154 MeV electrons can be used to effectively kill lung and prostate cancer cells, suggesting that VHEE would be a viable radiotherapy modality. Several studies have shown that VHEE has characteristics that would offer significant improvements over conventional photon radiotherapy for example, electrons are relatively easy to steer and can be used to deliver dose rapidly and with high efficiency. Studies have shown improved dose distribution with VHEE in treatment plans, in comparison to VMAT, indicating that VHEE can offer improved and safer treatment plans with reduced side effects. The biological response of cancer cells to VHEE has not been sufficiently studied as of yet, however this initial study provides some initial insights into cell damage. VHEE offers significant benefits over photon radiotherapy and therefore more studies are required to fully understand the biological effectiveness of VHEE.


Cell Survival , Lung Neoplasms , Prostatic Neoplasms , Relative Biological Effectiveness , Humans , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/pathology , Male , Lung Neoplasms/radiotherapy , Lung Neoplasms/pathology , Cell Survival/radiation effects , Electrons/therapeutic use , Particle Accelerators , PC-3 Cells , Cell Line, Tumor , A549 Cells
13.
Sci Data ; 11(1): 487, 2024 May 11.
Article En | MEDLINE | ID: mdl-38734679

Radiation therapy (RT) is a crucial treatment for head and neck squamous cell carcinoma (HNSCC); however, it can have adverse effects on patients' long-term function and quality of life. Biomarkers that can predict tumor response to RT are being explored to personalize treatment and improve outcomes. While tissue and blood biomarkers have limitations, imaging biomarkers derived from magnetic resonance imaging (MRI) offer detailed information. The integration of MRI and a linear accelerator in the MR-Linac system allows for MR-guided radiation therapy (MRgRT), offering precise visualization and treatment delivery. This data descriptor offers a valuable repository for weekly intra-treatment diffusion-weighted imaging (DWI) data obtained from head and neck cancer patients. By analyzing the sequential DWI changes and their correlation with treatment response, as well as oncological and survival outcomes, the study provides valuable insights into the clinical implications of DWI in HNSCC.


Diffusion Magnetic Resonance Imaging , Head and Neck Neoplasms , Humans , Head and Neck Neoplasms/diagnostic imaging , Head and Neck Neoplasms/radiotherapy , Radiotherapy, Image-Guided , Squamous Cell Carcinoma of Head and Neck/diagnostic imaging , Squamous Cell Carcinoma of Head and Neck/radiotherapy , Particle Accelerators
14.
Radiat Prot Dosimetry ; 200(8): 779-790, 2024 Jun 03.
Article En | MEDLINE | ID: mdl-38767288

Photon energy is higher than the (γ,n) threshold, allowing it to interact with the nuclei of materials with high z properties and liberate fast neutrons. This represents a potentially harmful source of radiation for humans and the environment. This study validated the Monte Carlo simulation, using the particle and heavy-ion transport code system (PHITS) on a TrueBeam 10-MV linear particle accelerator's head shielding model and then used this PHITS code to simulate a photo-neutron spectrum for the transport of the beam. The results showed that, when comparing the simulated to measured PDD and crosslines, 100% of the γ-indexes were <1 (γ3%/3mm) for both simulations, for both phase-space data source and a mono energy source. Neutron spectra were recorded in all parts of the TrueBeam's head, as well as photon neutron spectra at three points on the beamline.


Computer Simulation , Monte Carlo Method , Neutrons , Particle Accelerators , Photons , Particle Accelerators/instrumentation , Humans , Radiation Protection/methods , Heavy Ions , Radiation Dosage , Head/radiation effects , Radiometry/methods
15.
J Appl Clin Med Phys ; 25(6): e14388, 2024 Jun.
Article En | MEDLINE | ID: mdl-38762906

BACKGROUND: The ZAP-X system is a novel gyroscopic radiosurgical system based on a 3 MV linear accelerator and collimator cones with a diameter between 4 and 25 mm. Advances in imaging modalities to detect small and early-stage pathologies allow for an early and less invasive treatment, where a smaller collimator matching the anatomical target could provide better sparing of surrounding healthy tissue. PURPOSE: A novel 3 mm collimator cone for the ZAP-X was developed. This study aims to investigate the usability of a commercial diode detector (microSilicon) for the dosimetric characterization of this small collimator cone; and to investigate the underlying small field perturbation effects. METHODS: Profile measurements in five depths as well as PDD and output ratio measurements were performed with a microSilicon detector and radiochromic EBT3 films. In addition, comprehensive Monte Carlo simulations were performed to validate the measurement observations and to quantify the perturbation effects of the microSilicon detector in these extremely small field conditions. RESULTS: It is shown that the microSilicon detector enables an accurate dosimetric characterization of the 3 mm beam. The profile parameters, such as the FWHM and 20%-80% penumbra width, agree within 0.1 to 0.2 mm between film and detector measurements. The output ratios agree within the measurement uncertainty between microSilicon detector and films, whereas the comparisons of the PDD results show good agreement with the Monte Carlo simulations. The analysis of the perturbation factors of the microSilicon detector reveals a small field correction factor of approximately 3% for the 3 mm circular beam and a correction factor smaller than 1.5% for field diameters above 3 mm. CONCLUSIONS: It could be shown that the microSilicon detector is well-suitable for the characterization of the new 3 mm circular beam of the ZAP-X system.


Monte Carlo Method , Particle Accelerators , Phantoms, Imaging , Radiosurgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiosurgery/methods , Radiosurgery/instrumentation , Humans , Particle Accelerators/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Radiometry/methods , Radiometry/instrumentation , Computer Simulation , Radiotherapy, Intensity-Modulated/methods , Silicon/chemistry
16.
Appl Radiat Isot ; 210: 111359, 2024 Aug.
Article En | MEDLINE | ID: mdl-38772121

This study aimed to identify the optimal conditions for delivering sufficient doses to deep-seated lesions within short irradiation times for two boron carriers of different T/N ratios. The therapeutic depth and irradiation time of a neutron beam for beam shaping assemblies (BSAs) with a Li or Be target and a MgF2 or CaF2 moderator were examined with the fast-neutron dose per epithermal neutron (FNR) as a parameter. When T/N = 3.61, the therapeutic depth was almost saturated at an FNR of about 10 × 10-13 Gy cm2; when the FNR value was about 10 × 10-13 Gy cm2, the therapeutic depth of the neutron beam for the BSA with a Be target and a MgF2 moderator was almost identical to that for the neutron beam for the BSA with a Be target and a CaF2 moderator, and slightly greater than those for the neutron beams for the BSAs with a Li target and a MgF2 or CaF2 moderator; moreover, the irradiation time of the neutron beam for the BSA with a Be target and a MgF2 moderator was shorter than that for the neutron beam for the BSA with a Be target and a CaF2 moderator. When T/N = 100, the therapeutic depths of the neutron beams for the BSAs varied greatly depending on the FNR, and were greater than the corresponding values for T/N = 3.61. We therefore concluded that the BSA with a Be target and a MgF2 moderator that produced a neutron beam with an FNR of about 10 × 10-13 Gy cm2 is optimal for delivering sufficient doses to deep-seated lesions in short irradiation times when T/N = 3.61, and stricter control over FNR is required when T/N = 100.


Boron Neutron Capture Therapy , Radiotherapy Dosage , Boron Neutron Capture Therapy/methods , Humans , Neutrons/therapeutic use , Proton Therapy/methods , Particle Accelerators
17.
J Appl Clin Med Phys ; 25(6): e14407, 2024 Jun.
Article En | MEDLINE | ID: mdl-38775807

BACKGROUND: With the ever-increasing requirements of accuracy and personalization of radiotherapy treatments, stereotactic radiotherapy (SRT) with volumetric modulated arc therapy (VMAT) on O-ring Halcyon radiotherapy system could potentially provide a fast, safe, and feasible treatment option. PURPOSE: The purpose of this study was to assess the delivery of Halcyon VMAT plans for small targets. METHODS: Well-defined VMAT-SRT plans were created on Halcyon radiotherapy system with the stacked and staggered dual-layer MLC design for the film measurement set-up and the target sizes and shapes designed to emulate the targets of the stereotactic treatments. The planar dose distributions were acquired with film measurements and compared to a current clinical reference dose calculation with AcurosXB (v18.0, Varian Medical Systems) and to Monte Carlo simulations. With the collapsed arc versions of the VMAT-SRT plans, the uncertainty in dose delivery due to the multileaf collimator (MLC) without the gantry rotation could be separated and analyzed. RESULTS: The target size was mainly limited by the resolution originated from the design of the MLC leaves. The results of the collapsed arc versions of the plans show good consistency among measured, calculated, and simulated dose distributions. With the full VMAT plans, the agreement between calculated and simulated dose distributions was consistent with the collapsed arc versions. The measured dose distribution agreed with the calculated and simulated dose distributions within the target regions, but considerable local differences were observed in the margins of the target. The largest differences located in the steep gradient regions presumably originating from the deviation of the isocenter. CONCLUSIONS: The potential of the Halcyon radiotherapy system for VMAT-SRT delivery was evaluated and the study revealed valuable insights on the machine characteristics with the delivery.


Monte Carlo Method , Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Radiotherapy Planning, Computer-Assisted/methods , Humans , Radiotherapy, Intensity-Modulated/methods , Organs at Risk/radiation effects , Phantoms, Imaging , Particle Accelerators/instrumentation , Neoplasms/radiotherapy , Radiosurgery/methods
18.
J Appl Clin Med Phys ; 25(6): e14387, 2024 Jun.
Article En | MEDLINE | ID: mdl-38778567

INTRODUCTION: Radiation dose measurement is an essential part of radiotherapy to verify the correct delivery of doses to patients and ensure patient safety. Recent advancements in radiotherapy technology have highlighted the need for fast and precise dosimeters. Technologies like FLASH radiotherapy and magnetic-resonance linear accelerators (MR-LINAC) demand dosimeters that can meet their unique requirements. One promising solution is the plastic scintillator-based dosimeter with high spatial resolution and real-time dose output. This study explores the feasibility of using the LuSy dosimeter, an in-house developed plastic scintillator dosimeter for dose verification across various radiotherapy techniques, including conformal radiotherapy (CRT), intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT), and stereotactic radiosurgery (SRS). MATERIALS AND METHODS: A new dosimetry system, comprising a new plastic scintillator as the sensing material, was developed and characterized for radiotherapy beams. Treatment plans were created for conformal radiotherapy, IMRT, VMAT, and SRS and delivered to a phantom. LuSy dosimeter was used to measure the delivered dose for each plan on the surface of the phantom and inside the target volumes. Then, LuSy measurements were compared against an ionization chamber, MOSFET dosimeter, radiochromic films, and dose calculated using the treatment planning system (TPS). RESULTS: For CRT, surface dose measurement by LuSy dosimeter showed a deviation of -5.5% and -5.4% for breast and abdomen treatment from the TPS, respectively. When measuring inside the target volume for IMRT, VMAT, and SRS, the LuSy dosimeter produced a mean deviation of -3.0% from the TPS. Surface dose measurement resulted in higher TPS discrepancies where the deviations for IMRT, VMAT, and SRS were -2.0%, -19.5%, and 16.1%, respectively. CONCLUSION: The LuSy dosimeter was feasible for measuring radiotherapy doses for various treatment techniques. Treatment delivery verification enables early error detection, allowing for safe treatment delivery for radiotherapy patients.


Feasibility Studies , Particle Accelerators , Phantoms, Imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Particle Accelerators/instrumentation , Radiosurgery/methods , Radiation Dosimeters , Radiotherapy, Conformal/methods , Radiotherapy, Conformal/instrumentation , Radiometry/methods , Radiometry/instrumentation , Organs at Risk/radiation effects , Neoplasms/radiotherapy
19.
Phys Med ; 122: 103387, 2024 Jun.
Article En | MEDLINE | ID: mdl-38797025

OBJECTIVE: To study the effect of beam complexity on VMAT delivery accuracy evaluated by means of a transmission detector, together with the possibility of scoring plan complexity. METHODS: 43 clinical VMAT plans delivered by a TrueBeam linear accelerator to both Delta4 Discover and Delta4 Phantom+ for patient-specific quality assurance were evaluated. Global Dose-γ analysis, MLC-γ analysis, percentage of leaves with a deviation between planned and measured leaf tip position lower than 1 mm (LD) were computed. Modulation complexity score (MCSv), average leaf travel (LT), a multiplicative combination of LT and MCSv (LTMCS), percentage of leaves with speed lower than 5 mm/s (LS), from 5 to 20 mm/s (MS), higher than 20 mm/s (HS) and the average value of leaf speed (MLCSav) were evaluated by means of an home-made Matlab script. RESULTS: Dose-γ passing rate showed a moderate correlation with MCSv, LT, MLCSav, LS and HS, while a stronger positive correlation was found with LTMCS. A strong correlation was observed between LD and both LT and leaves speed, while a weak correlation was observed with MCSv. A correlation between MLC-γ pass rate and plan complexity parameters was found except for MCSv; a moderate correlation with LS was observed, while all other parameters showed weak correlations. CONCLUSIONS: The study confirmed the possibility to establish correlations between plan complexity indices versus dose distribution and MLC parameters measured by a transmissive detector. Further investigation is necessary to define specific values of the complexity indices to evaluate whether a VMAT plan is deliverable as intended.


Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Radiotherapy, Intensity-Modulated/methods , Radiotherapy, Intensity-Modulated/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Humans , Radiotherapy Dosage , Particle Accelerators
20.
Phys Med Biol ; 69(12)2024 Jun 12.
Article En | MEDLINE | ID: mdl-38810634

Objective. The purpose of this study was to assess a method of accelerating Monte Carlo simulations for modeling depth dose distributions from megavoltage x-ray beams by fitting them to an empirically-derived function.Approach. Using Geant4, multiple simulations of a typical medical linear accelerator beam in water and in water with an air cavity were conducted with varying numbers of initial electrons. The resulting percent depth dose curves were compared to published data from actual linear accelerator measurements. Two methods were employed to reduce computation time for this modeling process. First, an empirical function derived from measurements at a particular linear accelerator energy, source-to-surface distance, and field size was used to directly fit the simulated data. Second, a linear regression was performed to predict the empirical function's parameters for simulations with more initial electrons.Main results. Fitting simulated depth dose curves with the empirical function yielded significant improvements in either accuracy or computation time, corresponding to the two methods described. When compared to published measurements, the maximum error for the largest simulation was 5.58%, which was reduced to 2.01% with the best fit of the function. Fitting the empirical function around the air cavity heterogeneity resulted in errors less than 2.5% at the interfaces. The linear regression prediction modestly improved the same simulation with a maximum error of 4.22%, while reducing the required computation time from 66.53 h to 43.75 h.Significance. This study demonstrates the effective use of empirical functions to expedite Monte Carlo simulations for a range of applications from radiation protection to food sterilization. These results are particularly impactful in radiation therapy treatment planning, where time and accuracy are especially valuable. Employing these methods may improve patient outcomes by ensuring that dose delivery more accurately matches the prescription or by shortening the preparation time before treatment in Monte Carlo-based treatment planning systems.


Monte Carlo Method , Water , Radiation Dosage , X-Rays , Radiotherapy Dosage , Radiometry/methods , Particle Accelerators , Radiotherapy Planning, Computer-Assisted/methods , Time Factors
...