Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 53.990
Filter
1.
BMC Pregnancy Childbirth ; 24(1): 468, 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38982352

ABSTRACT

PURPOSE: This study evaluates the efficacy of intrauterine hCG perfusion for RIF, as defined by ESHRE 2023 guidelines, highlighting hCG as a cost-effective alternative to other immunotherapies, especially suitable for less developed regions. It aims to clarify treatment guidance amidst previous inconsistencies. METHODS: This meta-analysis, registered with PROSPERO (CRD42024443241) and adhering to PRISMA guidelines, assessed the efficacy and safety of intrauterine hCG perfusion in enhancing implantation and pregnancy outcomes in RIF. Comprehensive literature searches were conducted through December 2023 in major databases including PubMed, Web of Science, Embase, the Cochrane Library, and key Chinese databases, without language restrictions. Inclusion and exclusion criteria were strictly aligned with the 2023 ESHRE recommendations, with exclusions for studies lacking robust control, clear outcomes, or adequate data integrity. The risk of bias was evaluated using the Newcastle-Ottawa Scale, ROBINS-I, and RoB2 tools. Data analysis was performed in R using the 'meta' package, employing both fixed and random effect models to account for study variability. Subgroup analyses by dosage, volume, hCG concentration, timing of administration, and type of embryo transfer were conducted to deepen insights, enhancing the reliability and depth of the meta-analysis in elucidating the role of hCG perfusion in RIF treatments. RESULTS: Data from 13 studies, comprising six retrospective and six prospective studies from single centers, along with one multi-center RCT, totaling 2,157 participants, were synthesized to evaluate the effectiveness of intrauterine hCG perfusion in enhancing implantation and pregnancy outcomes in patients with RIF. Significant improvements were observed in clinical pregnancy and embryo implantation rates across various dosages, timing of administration, and embryo developmental stages, without impacting miscarriage rates. Notably, the most significant efficacy within subgroups occurred with a 500 IU dosage and perfusion parameters of ≤ 500µL volume and ≥ 2 IU/µL concentration. Additionally, a limited number of studies showed no significant increases in ectopic pregnancy or multiple pregnancy rates, and a modest improvement in live birth rates, although the small number of these studies precludes definitive conclusions. CONCLUSIONS: The analysis suggests that intrauterine hCG perfusion probably enhances embryo implantation, clinical pregnancy, and live birth rates slightly in RIF patients. Benefits are indicated with a dosage of 500 IU and a maximum volume of 500µL at concentrations of at least 2 IU/µL. However, substantial heterogeneity from varying study types and the limited number of studies necessitate cautious interpretation. These findings underscore the need for more rigorously designed RCTs to definitively assess the efficacy and safety.


Subject(s)
Chorionic Gonadotropin , Embryo Implantation , Humans , Female , Pregnancy , Chorionic Gonadotropin/administration & dosage , Chorionic Gonadotropin/blood , Perfusion/methods , Practice Guidelines as Topic , Embryo Transfer/methods , Pregnancy Outcome
2.
J Vis Exp ; (208)2024 Jun 28.
Article in English | MEDLINE | ID: mdl-39007610

ABSTRACT

Due to their physiological similarities to humans, pigs are used as experimental models for ex vivo lung perfusion (EVLP). EVLP is a technique that perfuses lungs that are not suitable for transplantation via an extracorporeal circulation pump to improve their function and increase their viability. Existing EVLP protocols are differentiated by the type of perfusion solution and perfusion flow, which varies from 40%-100% of the estimated cardiac output (CO) according to the body surface area (BSA). Devices for measuring CO use simple physical principles and other mathematical models. Thermodilution in animal models continues to be the reference standard for estimating CO because of its simplicity and ease of reproduction. Therefore, the objective of this study was to reproduce the measurement of CO by thermodilution in pigs and compare its precision and accuracy with those obtained by the BSA, weight, and Fick's method, to establish perfusion flow during EVLP. In 23 pigs, a thermodilution catheter was placed in the right jugular vein, and the carotid artery on the same side was cannulated. Blood samples were obtained for gasometry, and CO was estimated by thermodilution, adjusted body surface area, Fick's principle, and per body weight. The CO obtained by the BSA was greater (p = 0.0001, ANOVA, Tukey) than that obtained by the other methods. We conclude that although the methods used in this study to estimate CO are reliable, there are significant differences between them; therefore, each method must be evaluated by the investigator to determine which meets the needs of the protocol.


Subject(s)
Cardiac Output , Lung , Perfusion , Thermodilution , Animals , Swine , Perfusion/methods , Cardiac Output/physiology , Thermodilution/methods , Lung/physiology , Lung/blood supply , Models, Animal
3.
Eur J Med Res ; 29(1): 361, 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38992689

ABSTRACT

BACKGROUND: Liver grafts are frequently declined due to high donor age or age mismatch with the recipient. To improve the outcome of marginal grafts, we aimed to characterize the performance of elderly vs. young liver grafts in a standardized rat model of normothermic ex vivo liver machine perfusion (NMP). METHODS: Livers from Sprague-Dawley rats aged 3 or 12 months were procured and perfused for 6 h using a rat NMP system or collected as a reference group (n = 6/group). Tissue, bile, and perfusate samples were used for biochemical, and proteomic analyses. RESULTS: All livers cleared lactate during perfusion and continued to produce bile after 6 h of perfusion (614 mg/h). Peak urea levels in 12-month-old animals were higher than in younger animals. Arterial and portal venous pressure, bile production and pH did not differ between groups. Proteomic analysis identified a total of 1477 proteins with oxidoreductase and catalytic activity dominating the gene ontology analysis. Proteins such as aldehyde dehydrogenase 1A1 and 2-Hydroxyacid oxidase 2 were significantly more present in livers of older age. CONCLUSIONS: Young and elderly liver grafts exhibited similar viability during NMP, though proteomic analyses indicated that older grafts are less resilient to oxidative stress. Our study is limited by the elderly animal age, which corresponds to mature but not elderly human age typically seen in marginal human livers. Nevertheless, reducing oxidative stress could be a promising therapeutic target in the future.


Subject(s)
Liver Transplantation , Liver , Perfusion , Proteomics , Rats, Sprague-Dawley , Animals , Liver/metabolism , Rats , Perfusion/methods , Liver Transplantation/methods , Proteomics/methods , Male , Organ Preservation/methods , Humans , Oxidative Stress , Aging/metabolism
4.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 55(3): 574-579, 2024 May 20.
Article in Chinese | MEDLINE | ID: mdl-38948297

ABSTRACT

Objective: To investigate the effects of intrauterine perfusion with granulocyte colony-stimulating factor (G-CSF) on the endometrial thickness, volume, and blood flow parameters of patients with thin endometrium and their clinical outcomes. Methods: We designed a prospective non-randomized synchronous controlled trial and recruited patients with thin endometrium who underwent frozen-thawed embryo transfer (FET) at Mianyang Central Hospital between September 1, 2021 and September 1, 2023. They were divided into two groups, an experimental group of patients who received the experimental treatment of intrauterine perfusion with G-CSF and a control group of patients who did not receive the experimental treatment. The general data and the clinical outcomes of the two groups were analyzed and compared. The endometrial thickness, volume and blood flow parameters of patients in the experimental group before and after intrauterine perfusion with G-CSF were analyzed. Results: The clinical data of 83 patients were included in the study. The experimental group included 51 cases, while the control group included 31 cases. There were no significant differences in the baseline data between the two groups. The clinical pregnancy rate of the experimental group (56.86%) was higher than that of the control group (50.00%) and the rate of spontaneous abortion in the experimental group (27.59%) was lower than that in the control group (37.50%), but the differences were not statistically significant (P>0.05). In the experimental group, the postperfusion endometrial thickness ([0.67±0.1] cm) was greater than the preperfusion endometrial thickness ([0.59±0.09] cm), the postperfusion ([1.84±0.81] cm3) was greater than the preperfusion endometrial volume ([1.54±0.69] cm3), and the postperfusion vascularization flow index (VFI) (1.97±2.82) was greater than the preperfusion VFI (0.99±1.04), with all the differences being statistically significant (P<0.05). Conclusion: Intrauterine perfusion with G-CSF can enhance the endometrial thickness, volume, and some blood flow parameters in patients with thin endometrium.


Subject(s)
Embryo Transfer , Endometrium , Granulocyte Colony-Stimulating Factor , Pregnancy Rate , Humans , Female , Endometrium/blood supply , Granulocyte Colony-Stimulating Factor/administration & dosage , Granulocyte Colony-Stimulating Factor/therapeutic use , Granulocyte Colony-Stimulating Factor/pharmacology , Prospective Studies , Pregnancy , Embryo Transfer/methods , Adult , Perfusion
5.
J Vis Exp ; (208)2024 Jun 14.
Article in English | MEDLINE | ID: mdl-38949305

ABSTRACT

Conventional static cold storage (SCS) exacerbates ischemic injury in the DCD liver, leading to severe complications for transplant recipients. To address this issue, clinical application of MP technology for donor liver preservation is underway. Simultaneously, efforts are focused on the development of various MP instruments, validated through relevant animal model experiments. Effective large animal trials play a pivotal role in clinical applications. However, challenges persist in the ex vivo preservation of DCD livers and the transplantation procedure in pigs. These hurdles encompass addressing the prolonged preservation of donor livers, conducting viability tests, alleviating ischemic injuries, and shortening the anhepatic phase. The use of a variable temperature-controlled MP device facilitates the prolonged preservation of DCD livers through sequential Dual Hypothermic Oxygenated Machine Perfusion (DHOPE) and Normothermic Machine Perfusion (NMP) modes. This protocol enhances the porcine OLTx model by improving the quality of DCD livers, optimizing the anastomosis technique, and reducing the duration of the anhepatic phase.


Subject(s)
Liver Transplantation , Liver , Organ Preservation , Perfusion , Animals , Liver Transplantation/methods , Organ Preservation/methods , Swine , Perfusion/methods , Liver/surgery
6.
J Vis Exp ; (208)2024 Jun 14.
Article in English | MEDLINE | ID: mdl-38949317

ABSTRACT

Despite important advancements in the diagnosis and treatment of cardiovascular diseases (CVDs), the field is in urgent need of increased research and scientific advancement. As a result, innovation, improvement and/or repurposing of the available research toolset can provide improved testbeds for research advancement. Langendorff perfusion is an extremely valuable research technique for the field of CVD research that can be modified to accommodate a wide array of experimental needs. This tailoring can be achieved by personalizing a large number of perfusion parameters, including perfusion pressure, flow, perfusate, temperature, etc. This protocol demonstrates the versatility of Langendorff perfusion and the feasibility of achieving longer perfusion times (4 h) without graft function loss by utilizing lower perfusion pressures (30-35 mmHg). Achieving extended perfusion times without graft damage and/or function loss caused by the technique itself has the potential to eliminate confounding elements from experimental results. In effect, in scientific circumstances where longer perfusion times are relevant to the experimental needs (i.e., drug treatments, immunological response analysis, gene editing, graft preservation, etc.), lower perfusion pressures can be key for scientific success.


Subject(s)
Perfusion , Animals , Perfusion/methods , Rats , Heart Transplantation/methods , Isolated Heart Preparation/methods
7.
J Vis Exp ; (208)2024 Jun 14.
Article in English | MEDLINE | ID: mdl-38949382

ABSTRACT

Lung transplantation is hampered by the lack of suitable donors. Previously, donors that were thought to be marginal or inadequate were discarded. However, new and exciting technology, such as ex vivo lung perfusion (EVLP), offers lung transplant providers extended assessment for marginal donor allografts. This dynamic assessment platform has led to an increase in lung transplantation and has allowed providers to use donors that were previously discarded, thus expanding the donor pool. Current perfusion techniques use cellular or acellular perfusates, and both have distinct advantages and disadvantages. Perfusion composition is critical to maintaining a homeostatic environment, providing adequate metabolic support, decreasing inflammation and cellular death, and ultimately improving organ function. Perfusion solutions must contain sufficient protein concentration to maintain appropriate oncotic pressure. However, current perfusion solutions often lead to fluid extravasation through the pulmonary endothelium, resulting in inadvertent pulmonary edema and damage. Thus, it is necessary to develop novel perfusion solutions that prevent excessive damage while maintaining proper cellular homeostasis. Here, we describe the application of a polymerized human hemoglobin (PolyhHb)-based oxygen carrier as a perfusate and the protocol in which this perfusion solution can be tested in a model of rat EVLP. The goal of this study is to provide the lung transplant community with key information in designing and developing novel perfusion solutions, as well as the proper protocols to test them in clinically relevant translational transplant models.


Subject(s)
Hemoglobins , Lung Transplantation , Lung , Perfusion , Animals , Rats , Lung Transplantation/methods , Hemoglobins/chemistry , Perfusion/methods , Lung/metabolism , Humans , Oxygen/metabolism , Blood Substitutes/pharmacology , Blood Substitutes/chemistry , Male , Organ Preservation Solutions/chemistry
8.
Cochrane Database Syst Rev ; 7: CD011671, 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38979743

ABSTRACT

BACKGROUND: Kidney transplantation is the optimal treatment for kidney failure. Donation, transport and transplant of kidney grafts leads to significant ischaemia reperfusion injury. Static cold storage (SCS), whereby the kidney is stored on ice after removal from the donor until the time of implantation, represents the simplest preservation method. However, technology is now available to perfuse or "pump" the kidney during the transport phase ("continuous") or at the recipient centre ("end-ischaemic"). This can be done at a variety of temperatures and using different perfusates. The effectiveness of these treatments manifests as improved kidney function post-transplant. OBJECTIVES: To compare machine perfusion (MP) technologies (hypothermic machine perfusion (HMP) and (sub) normothermic machine perfusion (NMP)) with each other and with standard SCS. SEARCH METHODS: We contacted the information specialist and searched the Cochrane Kidney and Transplant Register of Studies until 15 June 2024 using search terms relevant to this review. Studies in the Register are identified through searches of CENTRAL, MEDLINE, and EMBASE, conference proceedings, the International Clinical Trials Registry Platform (ICTRP) Search Portal, and ClinicalTrials.gov. SELECTION CRITERIA: All randomised controlled trials (RCTs) and quasi-RCTs comparing machine perfusion techniques with each other or versus SCS for deceased donor kidney transplantation were eligible for inclusion. All donor types were included (donor after circulatory death (DCD) and brainstem death (DBD), standard and extended/expanded criteria donors). Both paired and unpaired studies were eligible for inclusion. DATA COLLECTION AND ANALYSIS: The results of the literature search were screened, and a standard data extraction form was used to collect data. Both of these steps were performed by two independent authors. Dichotomous outcome results were expressed as risk ratios (RR) with 95% confidence intervals (CI). Survival analyses (time-to-event) were performed with the generic inverse variance meta-analysis of hazard ratios (HR). Continuous scales of measurement were expressed as a mean difference (MD). Random effects models were used for data analysis. The primary outcome was the incidence of delayed graft function (DGF). Secondary outcomes included graft survival, incidence of primary non-function (PNF), DGF duration, economic implications, graft function, patient survival and incidence of acute rejection. Confidence in the evidence was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. MAIN RESULTS: Twenty-two studies (4007 participants) were included. The risk of bias was generally low across all studies and bias domains. The majority of the evidence compared non-oxygenated HMP with standard SCS (19 studies). The use of non-oxygenated HMP reduces the rate of DGF compared to SCS (16 studies, 3078 participants: RR 0.78, 95% CI 0.69 to 0.88; P < 0.0001; I2 = 31%; high certainty evidence). Subgroup analysis revealed that continuous (from donor hospital to implanting centre) HMP reduces DGF (high certainty evidence). In contrast, this benefit over SCS was not seen when non-oxygenated HMP was not performed continuously (low certainty evidence). Non-oxygenated HMP reduces DGF in both DCD and DBD settings in studies performed in the 'modern era' and when cold ischaemia times (CIT) were short. The number of perfusions required to prevent one episode of DGF was 7.69 and 12.5 in DCD and DBD grafts, respectively. Continuous non-oxygenated HMP versus SCS also improves one-year graft survival (3 studies, 1056 participants: HR 0.46, 0.29 to 0.75; P = 0.002; I2 = 0%; high certainty evidence). Assessing graft survival at maximal follow-up confirmed a benefit of continuous non-oxygenated HMP over SCS (4 studies, 1124 participants (follow-up 1 to 10 years): HR 0.55, 95% CI 0.40 to 0.77; P = 0.0005; I2 = 0%; high certainty evidence). This effect was not seen in studies where HMP was not continuous. The effect of non-oxygenated HMP on our other outcomes (PNF, incidence of acute rejection, patient survival, hospital stay, long-term graft function, duration of DGF) remains uncertain. Studies performing economic analyses suggest that HMP is either cost-saving (USA and European settings) or cost-effective (Brazil). One study investigated continuous oxygenated HMP versus non-oxygenated HMP (low risk of bias in all domains); the simple addition of oxygen during continuous HMP leads to additional benefits over non-oxygenated HMP in DCD donors (> 50 years), including further improvements in graft survival, improved one-year kidney function, and reduced acute rejection. One large, high-quality study investigated end-ischaemic oxygenated HMP versus SCS and found end-ischaemic oxygenated HMP (median machine perfusion time 4.6 hours) demonstrated no benefit compared to SCS. The impact of longer periods of end-ischaemic HMP is unknown. One study investigated NMP versus SCS (low risk of bias in all domains). One hour of end ischaemic NMP did not improve DGF compared with SCS alone. An indirect comparison revealed that continuous non-oxygenated HMP (the most studied intervention) was associated with improved graft survival compared with end-ischaemic NMP (indirect HR 0.31, 95% CI 0.11 to 0.92; P = 0.03). No studies investigated normothermic regional perfusion (NRP) or included any donors undergoing NRP. AUTHORS' CONCLUSIONS: Continuous non-oxygenated HMP is superior to SCS in deceased donor kidney transplantation, reducing DGF, improving graft survival and proving cost-effective. This is true for both DBD and DCD kidneys, both short and long CITs, and remains true in the modern era (studies performed after 2008). In DCD donors (> 50 years), the simple addition of oxygen to continuous HMP further improves graft survival, kidney function and acute rejection rate compared to non-oxygenated HMP. Timing of HMP is important, and benefits have not been demonstrated with short periods (median 4.6 hours) of end-ischaemic HMP. End-ischaemic NMP (one hour) does not confer meaningful benefits over SCS alone and is inferior to continuous HMP in an indirect comparison of graft survival. Further studies assessing NMP for viability assessment and therapeutic delivery are warranted and in progress.


Subject(s)
Graft Survival , Kidney Transplantation , Organ Preservation , Perfusion , Randomized Controlled Trials as Topic , Humans , Cold Temperature , Delayed Graft Function/prevention & control , Kidney , Kidney Transplantation/methods , Organ Preservation/methods , Perfusion/methods , Perfusion/instrumentation , Reperfusion Injury/prevention & control , Temperature , Tissue Donors
9.
J Avian Med Surg ; 38(2): 91-97, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38980818

ABSTRACT

Intravenous regional limb perfusion (IVRLP) has been used in the treatment of pododermatitis and distal limb infections, which are significant causes of morbidity in avian species. This intravenous drug administration technique is designed to achieve high drug tissue concentrations while minimizing systemic toxic effects. Amikacin is commonly used for IVRLP in veterinary medicine, but dosing guidelines have not been established for its use in birds. The current study aimed to determine the tissue concentration of amikacin after a single IVRLP administration in healthy, euhydrated leghorn hen chickens (Gallus gallus domesticus). Chickens received a single IVRLP dose of 10 mg/kg amikacin and were euthanatized posttreatment at 1 hour (n = 6), 12 hours (n = 6), and 24 hours (n = 6) to assess tissue and synovial fluid concentrations of amikacin in the injected leg. Mean tissue concentrations were highest 1 hour post-IVRLP (synovial fluid = 153.0 µg/mL, metatarsal pad tissue = 26.05 µg/mL) before declining at the 12- and 24-hour time points. This indicates that administration of amikacin via IVRLP can reach minimum inhibitory concentrations of common bacterial isolates in tissues after a single treatment with 10 mg/kg amikacin. Regional limb perfusion every 24 hours is recommended, although the minimum days of treatment may be case dependent and vary based on response to therapy.


Subject(s)
Amikacin , Anti-Bacterial Agents , Chickens , Animals , Amikacin/pharmacokinetics , Amikacin/administration & dosage , Anti-Bacterial Agents/pharmacokinetics , Anti-Bacterial Agents/administration & dosage , Synovial Fluid/chemistry , Perfusion/veterinary , Female , Hindlimb/blood supply
10.
Exp Clin Transplant ; 22(5): 351-357, 2024 May.
Article in English | MEDLINE | ID: mdl-38970278

ABSTRACT

OBJECTIVES: With the increase in life expectancy and the aging of the population, chronic kidney disease has become increasingly prevalent in our environment. Kidney transplantation remains the gold standard treatment for end-stage renal disease, but the supply of renal grafts has not been able to keep pace with growing demand. Because of this rationale, organ selection criteria have been extended (expanded criteria donation), and alternative donation types, such as donation after circulatory death, have been evaluated. These approaches aim to increase the pool of potential donors, albeit with organs of potentially lower quality. Various forms of donations, including donation after circulatory death, have also undergone assessment. This approach aims to augment the pool of potential donors, notwithstanding the compromised quality of organs associated with such methods. Diverse strategies have been explored to enhance graft function, with one of the most promising being the utilization of pulsatile machine perfusion. MATERIALS AND METHODS: We conducted a retrospective analysis on 28 transplant recipients who met the inclusion criterion of sharing the same donor, wherein one organ was preserved by cold storage and the other by pulsatile machine perfusion. We performed statistical analysis on posttransplant recovery parameters throughout the patients' hospitalization, including admission and discharge phases. RESULTS: Statistically significant differences were noted in delayed graft function (P = .04), blood transfusions requirements, and Clavien-Dindo complications. Furthermore, an overall trend of improvement in discharge parameters and hospital stay was in favor of the pulsatile machine perfusion group. CONCLUSIONS: The use of pulsatile machine perfusion as a method of renal preservation results in graft optimization, leading to earlier recovery and fewer complications compared with cold storage in the context of donation after circulatory death.


Subject(s)
Delayed Graft Function , Kidney Transplantation , Perfusion , Pulsatile Flow , Recovery of Function , Humans , Kidney Transplantation/adverse effects , Retrospective Studies , Treatment Outcome , Time Factors , Male , Female , Perfusion/methods , Perfusion/adverse effects , Middle Aged , Adult , Delayed Graft Function/etiology , Delayed Graft Function/prevention & control , Risk Factors , Tissue Donors/supply & distribution , Organ Preservation/methods , Organ Preservation/adverse effects , Donor Selection , Heart Arrest/diagnosis , Heart Arrest/physiopathology , Heart Arrest/etiology
11.
Biotechnol J ; 19(7): e2400092, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38987222

ABSTRACT

Continuous manufacturing enables high volumetric productivities of biologics such as monoclonal antibodies. However, it is challenging to maintain both high viable cell densities and productivities at the same time for long culture durations. One of the key controls in a perfusion process is the perfusion rate which determines the nutrient availability and potentially controls the cell metabolism. Cell Specific Perfusion Rate (CSPR) is a feed rate proportional to the viable cell density while Biomass Specific Perfusion Rate (BSPR) is a feed rate proportional to the biomass (cell volume multiply by cell density). In this study, perfusion cultures were run at three BSPRs in the production phase. Low BSPR favored a growth arresting state that led to gradual increase in cell volume, which in turn led to an increase in net perfusion rate proportional to the increase in cell volume. Consequently, at low BSPR, while the cell viability and cell density decreased, high specific productivity of 55 pg per cell per day was achieved. In contrast, the specific productivity was lower in bioreactors operating at a high BSPR. The ability to modulate the cell metabolism by using BSPR was confirmed when the specific productivity increased after lowering the BSPR in one of the bioreactors that was initially operating at a high BSPR. This study demonstrated that BSPR significantly influenced cell growth, metabolism, and productivity in cultures with variable cell volumes.


Subject(s)
Antibodies, Monoclonal , Biomass , Bioreactors , Biosimilar Pharmaceuticals , Cell Culture Techniques , Cricetulus , CHO Cells , Animals , Cell Culture Techniques/methods , Cell Survival/drug effects , Cell Count , Cell Proliferation/drug effects , Perfusion/methods
12.
Front Immunol ; 15: 1404668, 2024.
Article in English | MEDLINE | ID: mdl-38903492

ABSTRACT

Heart transplantation is associated with major hurdles, including the limited number of available organs for transplantation, the risk of rejection due to genetic discrepancies, and the burden of immunosuppression. In this study, we demonstrated the feasibility of permanent genetic engineering of the heart during ex vivo perfusion. Lentiviral vectors encoding for short hairpin RNAs targeting beta2-microglobulin (shß2m) and class II transactivator (shCIITA) were delivered to the graft during two hours of normothermic EVHP. Highly efficient genetic engineering was indicated by stable reporter gene expression in endothelial cells and cardiomyocytes. Remarkably, swine leucocyte antigen (SLA) class I and SLA class II expression levels were decreased by 66% and 76%, respectively, in the vascular endothelium. Evaluation of lactate, troponin T, and LDH levels in the perfusate and histological analysis showed no additional cell injury or tissue damage caused by lentiviral vectors. Moreover, cytokine secretion profiles (IL-6, IL-8, and TNF-α) of non-transduced and lentiviral vector-transduced hearts were comparable. This study demonstrated the ex vivo generation of genetically engineered hearts without compromising tissue integrity. Downregulation of SLA expression may contribute to reduce the immunogenicity of the heart and support graft survival after allogeneic or xenogeneic transplantation.


Subject(s)
Genetic Vectors , Heart Transplantation , Histocompatibility Antigens Class I , Lentivirus , Animals , Lentivirus/genetics , Heart Transplantation/methods , Genetic Vectors/genetics , Swine , Histocompatibility Antigens Class I/genetics , Histocompatibility Antigens Class I/immunology , Histocompatibility Antigens Class I/metabolism , Perfusion/methods , Histocompatibility Antigens Class II/genetics , Histocompatibility Antigens Class II/metabolism , Histocompatibility Antigens Class II/immunology , beta 2-Microglobulin/genetics , Cytokines/metabolism , Genetic Engineering , Myocytes, Cardiac/metabolism , Myocytes, Cardiac/immunology , Humans , RNA, Small Interfering/genetics , Graft Survival/immunology , Graft Survival/genetics , Endothelial Cells/metabolism , Endothelial Cells/immunology , Nuclear Proteins , Trans-Activators
14.
Biofabrication ; 16(4)2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38906132

ABSTRACT

The ability to controllably perfuse kidney organoids would better recapitulate the native tissue microenvironment for applications ranging from drug testing to therapeutic use. Here, we report a perfusable, vascularized kidney organoid on chip model composed of two individually addressable channels embedded in an extracellular matrix (ECM). The channels are respectively seeded with kidney organoids and human umbilical vein endothelial cells that form a confluent endothelium (macrovessel). During perfusion, endogenous endothelial cells present within the kidney organoids migrate through the ECM towards the macrovessel, where they form lumen-on-lumen anastomoses that are supported by stromal-like cells. Once micro-macrovessel integration is achieved, we introduced fluorescently labeled dextran of varying molecular weight and red blood cells into the macrovessel, which are transported through the microvascular network to the glomerular epithelia within the kidney organoids. Our approach for achieving controlled organoid perfusion opens new avenues for generating other perfused human tissues.


Subject(s)
Human Umbilical Vein Endothelial Cells , Kidney , Organoids , Perfusion , Organoids/cytology , Humans , Kidney/cytology , Kidney/blood supply , Lab-On-A-Chip Devices , Animals , Tissue Engineering/methods , Extracellular Matrix/metabolism
15.
J Neurosci Methods ; 408: 110181, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38823594

ABSTRACT

BACKGROUND: Ex vivo cultures of retinal explants are appropriate models for translational research. However, one of the difficult problems of retinal explants ex vivo culture is that their nutrient supply needs cannot be constantly met. NEW METHOD: This study evaluated the effect of perfused culture on the survival of retinal explants, addressing the challenge of insufficient nutrition in static culture. Furthermore, exosomes secreted from retinal organoids (RO-Exos) were stained with PKH26 to track their uptake in retinal explants to mimic the efficacy of exosomal drugs in vivo. RESULTS: We found that the retinal explants cultured with perfusion exhibited significantly higher viability, increased NeuN+ cells, and reduced apoptosis compared to the static culture group at Days Ex Vivo (DEV) 4, 7, and 14. The perfusion-cultured retinal explants exhibited reduced mRNA markers for gliosis and microglial activation, along with lower expression of GFAP and Iba1, as revealed by immunostaining. Additionally, RNA-sequencing analysis showed that perfusion culture mainly upregulated genes associated with visual perception and photoreceptor cell maintenance while downregulating the immune system process and immune response. RO-Exos promoted the uptake of PKH26-labelled exosomes and the growth of retinal explants in perfusion culture. COMPARISON WITH EXISTING METHODS: Our perfusion culture system can provide a continuous supply of culture medium to achieve steady-state equilibrium in retinal explant culture. Compared to traditional static culture, it better preserves the vitality, provides better neuroprotection, and reduces glial activation. CONCLUSIONS: This study provides a promising ex vivo model for further studies on degenerative retinal diseases and drug screening.


Subject(s)
Exosomes , Organoids , Retina , Animals , Organoids/metabolism , Retina/cytology , Retina/metabolism , Exosomes/metabolism , Perfusion/methods , Mice , Mice, Inbred C57BL , Tissue Culture Techniques/methods , Cell Survival/physiology , Cell Survival/drug effects
16.
Trials ; 25(1): 386, 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38886851

ABSTRACT

BACKGROUND: Liver disease is the third leading cause of premature death in the UK. Transplantation is the only successful treatment for end-stage liver disease but is limited by a shortage of suitable donor organs. As a result, up to 20% of patients on liver transplant waiting lists die before receiving a transplant. A third of donated livers are not suitable for transplant, often due to steatosis. Hepatic steatosis, which affects 33% of the UK population, is strongly associated with obesity, an increasing problem in the potential donor pool. We have recently tested defatting interventions during normothermic machine perfusion (NMP) in discarded steatotic human livers that were not transplanted. A combination of therapies including forskolin (NKH477) and L-carnitine to defat liver cells and lipoprotein apheresis filtration were investigated. These interventions resulted in functional improvement during perfusion and reduced the intrahepatocellular triglyceride (IHTG) content. We hypothesise that defatting during NMP will allow more steatotic livers to be transplanted with improved outcomes. METHODS: In the proposed multi-centre clinical trial, we will randomly assign 60 livers from donors with a high-risk of hepatic steatosis to either NMP alone or NMP with defatting interventions. We aim to test the safety and feasibility of the defatting intervention and will explore efficacy by comparing ex-situ and post-reperfusion liver function between the groups. The primary endpoint will be the proportion of livers that achieve predefined functional criteria during perfusion which indicate potential suitability for transplantation. These criteria reflect hepatic metabolism and injury and include lactate clearance, perfusate pH, glucose metabolism, bile composition, vascular flows and transaminase levels. Clinical secondary endpoints will include proportion of livers transplanted in the two arms, graft function; cell-free DNA (cfDNA) at follow-up visits; patient and graft survival; hospital and ITU stay; evidence of ischemia-reperfusion injury (IRI); non-anastomotic biliary strictures and recurrence of steatosis (determined on MRI at 6 months). DISCUSSION: This study explores ex-situ pharmacological optimisation of steatotic donor livers during NMP. If the intervention proves effective, it will allow the safe transplantation of livers that are currently very likely to be discarded, thereby reducing waiting list deaths. TRIAL REGISTRATION: ISRCTN ISRCTN14957538. Registered in October 2022.


Subject(s)
Fatty Liver , Liver Transplantation , Perfusion , Randomized Controlled Trials as Topic , Humans , Liver Transplantation/methods , Perfusion/methods , Fatty Liver/therapy , Tissue Donors/supply & distribution , Liver/pathology , Multicenter Studies as Topic , Organ Preservation/methods , Time Factors , Treatment Outcome
18.
Br J Surg ; 111(6)2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38875136

ABSTRACT

BACKGROUND: Biomarkers with strong predictive capacity towards transplantation outcome for livers undergoing normothermic machine perfusion (NMP) are needed. We investigated lactate clearing capacity as a basic function of liver viability during the first 6 h of NMP. METHODS: A trial conducted in 6 high-volume transplant centres in Europe. All centres applied a back-to-base NMP approach with the OrganOx metra system. Perfusate lactate levels at start, 1, 2, 4 and 6 h of NMP were assessed individually and as area under the curve (AUC) and correlated with EAD (early allograft dysfunction), MEAF (model for early allograft function) and modified L-GrAFT (liver graft assessment following transplantation) scores. RESULTS: A total of 509 livers underwent ≥6 h of NMP before transplantation in 6 centres in the UK, Germany and Austria. The donor age was 53 (40-63) years (median, i.q.r.).The total NMP time was 10.8 (7.9-15.7) h. EAD occurred in 26%, MEAF was 4.72 (3.54-6.05) and L-GrAFT10 -0.96 (-1.52--0.32). Lactate at 1, 2 and 6 h correlated with increasing robustness with MEAF. Rather than a binary assessment with a cut-off value at 2 h, the actual 2 h lactate level correlated with the MEAF (P = 0.0306 versus P = 0.0002, Pearson r = 0.01087 versus r = 0.1734). The absolute lactate concentration at 6 h, the AUC of 0-6 h and 1-6 h (P < 0.0001, r = 0.3176) were the strongest predictors of MEAF. CONCLUSION: Lactate measured 1-6 h and lactate levels at 6 h correlate strongly with risk of liver allograft dysfunction upon transplantation. The robustness of predicting MEAF by lactate increases with perfusion duration. Monitoring lactate levels should be extended to at least 6 h of NMP routinely to improve clinical outcome.


Subject(s)
Lactic Acid , Liver Transplantation , Perfusion , Humans , Middle Aged , Male , Female , Perfusion/methods , Lactic Acid/metabolism , Adult , Biomarkers/metabolism , Organ Preservation/methods , Graft Survival , Predictive Value of Tests , Treatment Outcome
19.
Transpl Int ; 37: 12787, 2024.
Article in English | MEDLINE | ID: mdl-38845758

ABSTRACT

Organ quality can be assessed prior to transplantation, during normothermic machine perfusion (NMP) of the liver. Evaluation of mitochondrial function by high-resolution respirometry (HRR) may serve as a viability assessment concept in this setting. Freshly collected tissue is considered as optimal sample for HRR, but due to technical and personnel requirements, more flexible and schedulable measurements are needed. However, the impact of cold storage following NMP before processing biopsy samples for mitochondrial analysis remains unknown. We aimed at establishing an appropriate storage protocol of liver biopsies for HRR. Wedge biopsies of 5 human livers during NMP were obtained and assessed by HRR. Analysis was performed after 0, 4, 8, and 12 h of hypothermic storage (HTS) in HTK organ preservation solution at 4°C. With HTS up to 4 h, mitochondrial performance did not decrease in HTS samples compared with 0 h (OXPHOS, 44.62 [34.75-60.15] pmol·s-1·mg wet mass-1 vs. 43.73 [40.69-57.71], median [IQR], p > 0.999). However, at HTS beyond 4 h, mitochondrial respiration decreased. We conclude that HTS can be safely applied for extending the biopsy measurement window for up to 4 h to determine organ quality, but also that human liver respiration degrades beyond 4 h HTS following NMP.


Subject(s)
Liver Transplantation , Liver , Organ Preservation , Perfusion , Humans , Organ Preservation/methods , Liver/pathology , Biopsy , Male , Middle Aged , Female , Mitochondria, Liver/metabolism , Organ Preservation Solutions , Aged , Cell Respiration , Adult
20.
Am J Bioeth ; 24(6): 16-26, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38829597

ABSTRACT

Donation after circulatory determination of death (DCDD) is an accepted practice in the United States, but heart procurement under these circumstances has been debated. Although the practice is experiencing a resurgence due to the recently completed trials using ex vivo perfusion systems, interest in thoracoabdominal normothermic regional perfusion (TA-NRP), wherein the organs are reanimated in situ prior to procurement, has raised many ethical questions. We outline practical, ethical, and equity considerations to ensure transplant programs make well-informed decisions about TA-NRP. We present a multidisciplinary analysis of the relevant ethical issues arising from DCDD-NRP heart procurement, including application of the Dead Donor Rule and the Uniform Definition of Death Act, and provide recommendations to facilitate ethical analysis and input from all interested parties. We also recommend informed consent, as distinct from typical "authorization," for cadaveric organ donation using TA-NRP.


Subject(s)
Heart Transplantation , Perfusion , Tissue and Organ Procurement , Humans , Heart Transplantation/ethics , Tissue and Organ Procurement/ethics , Organ Preservation/ethics , United States , Tissue Donors/ethics , Informed Consent/ethics , Death , Cadaver
SELECTION OF CITATIONS
SEARCH DETAIL
...