Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.568
Filter
1.
Mikrochim Acta ; 191(7): 438, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38951285

ABSTRACT

A dual-recognition strategy is reported to construct a one-step washing and highly efficient signal-transduction tag system for high-sensitivity colorimetric detection of Staphylococcus aureus (S. aureus). The porous (gold core)@(platinum shell) nanozymes (Au@PtNEs) as the signal labels show highly efficient peroxidase mimetic activity and are robust. For the sake of simplicity the detection involved the use of a vancomycin-immobilized magnetic bead (MB) and aptamer-functionalized Au@PtNEs for dual-recognition detection in the presence of S. aureus. In addition, we designed a magnetic plate to fit the 96-well microplate to ensure consistent magnetic properties of each well, which can quickly remove unreacted Au@PtNEs and sample matrix while avoiding tedious washing steps. Subsequently, Au@PtNEs catalyze hydrogen peroxide (H2O2) to oxidize 3,3',5,5'-tetramethylbenzidine (TMB) generating a color signal. Finally, the developed Au@PtNEs-based dual-recognition washing-free colorimetric assay displayed a response in the range of S. aureus of 5 × 101-5 × 105 CFU/mL, and the detection limit was 40 CFU/mL within 1.5 h. In addition, S. aureus-fortified samples were analyzed to further evaluate the performance of the proposed method, which yielded average recoveries ranging from 93.66 to 112.44% and coefficients of variation (CVs) within the range 2.72-9.01%. These results furnish a novel horizon for the exploitation of a different mode of recognition and inexpensive enzyme-free assay platforms as an alternative to traditional enzyme-based immunoassays for the detection of other Gram-positive pathogenic bacteria.


Subject(s)
Benzidines , Colorimetry , Gold , Hydrogen Peroxide , Limit of Detection , Platinum , Staphylococcus aureus , Staphylococcus aureus/isolation & purification , Colorimetry/methods , Gold/chemistry , Platinum/chemistry , Porosity , Benzidines/chemistry , Hydrogen Peroxide/chemistry , Aptamers, Nucleotide/chemistry , Metal Nanoparticles/chemistry , Vancomycin/chemistry , Biosensing Techniques/methods , Catalysis , Humans
2.
Biosensors (Basel) ; 14(6)2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38920594

ABSTRACT

Conventional electrochemical sensors use voltammetric and amperometric methods with external power supply and modulation systems, which hinder the flexibility and application of the sensors. To avoid the use of an external power system and to minimize the number of electrochemical cell components, a self-powered electrochemical sensor (SPES) for hydrogen peroxide was investigated here. Iron phthalocyanine, an enzyme mimetic material, and Ni were used as a cathode catalyst and an anode material, respectively. The properties of the iron phthalocyanine catalyst modified by graphene nanoplatelets (GNPs) were investigated. Open circuit potential tests demonstrated the feasibility of this system. The GNP-modulated interface helped to solve the problems of aggregation and poor conductivity of iron phthalocyanine and allowed for the achievement of the best analytical characteristics of the self-powered H2O2 sensor with a low detection limit of 0.6 µM and significantly higher sensitivity of 0.198 A/(M·cm2) due to the enhanced electrochemical properties. The SPES demonstrated the best performance at pH 3.0 compared to pH 7.4 and 12.0. The sensor characteristics under the control of external variable load resistances are discussed and the cell showed the highest power density of 65.9 µW/cm2 with a 20 kOhm resistor. The practical applicability of this method was verified by the determination of H2O2 in blood serum.


Subject(s)
Biosensing Techniques , Electrochemical Techniques , Electrodes , Graphite , Hydrogen Peroxide , Graphite/chemistry , Catalysis , Indoles/chemistry , Limit of Detection , Ferrous Compounds/chemistry , Platinum/chemistry , Nickel/chemistry
3.
Int J Nanomedicine ; 19: 5227-5243, 2024.
Article in English | MEDLINE | ID: mdl-38855734

ABSTRACT

Purpose: This study aimed to construct targeting drug-loading nanocomposites (FA-FePt/DDP nanoliposomes) to explore their potential in ovarian cancer therapy and molecular magnetic resonance imaging (MMRI). Methods: FA-FePt-NPs were prepared by coupling folate (FA) with polyethylene-glycol (PEG)-coated ferroplatinum nanoparticles and characterized. Then cisplatin (DDP) was encapsulated in FA-FePt-NPs to synthesize FA-PEG-FePt/DDP nanoliposomes by thin film-ultrasonic method and high-speed stirring, of which MMRI potential, magnetothermal effect, and the other involved performance were analyzed. The therapeutic effect of FA-FePt/DDP nanoliposomes combined with magnetic fluid hyperthermia (MFH) on ovarian cancer in vitro and in vivo was evaluated. The expression levels of Bax and epithelial-mesenchymal transition related proteins were detected. The biosafety was also preliminarily observed. Results: The average diameter of FA-FePt-NPs was about 30 nm, FA-FePt/DDP nanoliposomes were about 70 nm in hydrated particle size, with drug slow-release and good cell-specific targeted uptake. In an alternating magnetic field (AMF), FA-FePt/DDP nanoliposomes could rapidly reach the ideal tumor hyperthermia temperature (42~44 °C). MRI scan showed that FA-FePt-NPs and FA-FePt/DDP nanoliposomes both could suppress the T2 signal, indicating a good potential for MMRI. The in vitro and in vivo experiments showed that FA-FePt/DDP-NPs in AMF could effectively inhibit the growth of ovarian cancer by inhibiting cancer cell proliferation, invasion, and migration, and inducing cancer cell apoptosis, much better than that of the other individual therapies; molecularly, E-cadherin and Bax proteins in ovarian cancer cells and tissues were significantly increased, while N-cadherin, Vimentin, and Bcl-2 proteins were inhibited, effectively inhibiting the malignant progression of ovarian cancer. In addition, no significant pathological injury and dysfunction was observed in major visceras. Conclusion: We successfully synthesized FA-FePt/DDP nanoliposomes and confirmed their good thermochemotherapeutic effect in AMF and MMRI potential on ovarian cancer, with no obvious side effects, providing a favorable strategy of integrated targeting therapy and diagnosis for ovarian cancer.


Subject(s)
Antineoplastic Agents , Cisplatin , Folic Acid , Liposomes , Magnetic Resonance Imaging , Ovarian Neoplasms , Polyethylene Glycols , Female , Ovarian Neoplasms/diagnostic imaging , Ovarian Neoplasms/therapy , Liposomes/chemistry , Cisplatin/pharmacology , Cisplatin/chemistry , Cisplatin/administration & dosage , Cisplatin/pharmacokinetics , Animals , Folic Acid/chemistry , Folic Acid/pharmacology , Folic Acid/pharmacokinetics , Humans , Magnetic Resonance Imaging/methods , Polyethylene Glycols/chemistry , Cell Line, Tumor , Antineoplastic Agents/chemistry , Antineoplastic Agents/pharmacology , Antineoplastic Agents/administration & dosage , Antineoplastic Agents/pharmacokinetics , Mice , Platinum/chemistry , Platinum/pharmacology , Hyperthermia, Induced/methods , Nanocomposites/chemistry , Mice, Nude , Mice, Inbred BALB C , Metal Nanoparticles/chemistry , Magnetic Fields , Particle Size
4.
Nanotechnology ; 35(36)2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38838648

ABSTRACT

Ascorbic acid (AA), known as vitamin C, is a vital bioactive compound that plays a crucial role in several metabolic processes, including the synthesis of collagen and neurotransmitters, the removal of harmful free radicals, and the uptake of iron by cells in the human intestines. As a result, there is an absolute need for a highly selective, sensitive, and economically viable sensing platform for AA detection. Herein, we demonstrate a Pt-decorated MoS2for efficient detection of an AA biosensor. MoS2hollow rectangular structures were synthesized using an easy and inexpensive chemical vapor deposition approach to meet the increasing need for a reliable detection platform. The synthesized MoS2hollow rectangular structures are characterized through field effect scanning electron microscopy (FESEM), energy-dispersive spectroscopy elemental mapping, Raman spectroscopy, and x-ray photoelectron spectroscopy. We fabricate a chemiresistive biosensor based on Pt-decorated MoS2that measures AA with great precision and high sensitivity. The experiments were designed to evaluate the response of the Pt-decorated MoS2biosensor in the presence and absence of AA, and selectivity was evaluated for a variety of biomolecules, and it was observed to be very selective towards AA. The Pt-MoS2device had a higher response of 125% against 1 mM concentration of AA biomolecules, when compared to that of all other devices and 2.2 times higher than that of the pristine MoS2device. The outcomes of this study demonstrate the efficacy of Pt-decorated MoS2as a promising material for AA detection. This research contributes to the ongoing efforts to enhance our capabilities in monitoring and detecting AA, fostering advancements in environmental, biomedical, and industrial applications.


Subject(s)
Ascorbic Acid , Biosensing Techniques , Disulfides , Molybdenum , Platinum , Ascorbic Acid/analysis , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Disulfides/chemistry , Molybdenum/chemistry , Platinum/chemistry , Humans , Spectrum Analysis, Raman/methods
5.
Anal Chem ; 96(25): 10434-10442, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38866710

ABSTRACT

Plasma protein adsorption on blood-contacting surfaces is the initiating significant event and modulates the subsequent coagulation response. Despite decades of research in this area, Vroman's questions in 1986 "Who gets there first?" and "When does the next protein arrive?" remain unanswered due to the lack of detection techniques with sufficient temporal resolution. In this work, we develop a droplet microfluidic technology to detect protein adsorption sequences on six typical blood-contacting surfaces in milliseconds. Apolipoproteins (Apo) are found to be the first proteins to adsorb onto the surfaces in a plasma droplet, and the specific type of apolipoprotein depends on the surface. Apo CI is the first protein adsorbed on gold, platinum, graphene, stainless steel, and polyvinyl chloride with the adsorption time varying from 0.01 to 1 s, while Apo CIII preferentially reaches the titanium alloy surface within 1 s. Subsequent to the initial adsorption, Apo AI, AII, and other proteins continue to adsorb until albumin arrives. Thus, the adsorption sequence is revealed, and Vroman's questions are answered. Moreover, this finding demonstrates the influence of the initial protein adsorption on subsequent coagulation at the surface, and it offers new insights into the development of anticoagulant surfaces.


Subject(s)
Surface Properties , Adsorption , Humans , Blood Proteins/chemistry , Blood Proteins/metabolism , Gold/chemistry , Stainless Steel/chemistry , Graphite/chemistry , Apolipoproteins/chemistry , Polyvinyl Chloride/chemistry , Platinum/chemistry , Microfluidic Analytical Techniques , Titanium/chemistry
6.
Int J Nanomedicine ; 19: 5045-5056, 2024.
Article in English | MEDLINE | ID: mdl-38832334

ABSTRACT

Background: Chemodynamic therapy (CDT) is a new treatment approach that is triggered by endogenous stimuli in specific intracellular conditions for generating hydroxyl radicals. However, the efficiency of CDT is severely limited by Fenton reaction agents and harsh reaction conditions. Methods: Bimetallic PtMn nanocubes were rationally designed and simply synthesized through a one-step high-temperature pyrolysis process by controlling both the nucleation process and the subsequent crystal growth stage. The polyethylene glycol was modified to enhance biocompatibility. Results: Benefiting from the alloying of Pt nanocubes with Mn doping, the structure of the electron cloud has changed, resulting in different degrees of the shift in electron binding energy, resulting in the increasing of Fenton reaction activity. The PtMn nanocubes could catalyze endogenous hydrogen peroxide to toxic hydroxyl radicals in mild acid. Meanwhile, the intrinsic glutathione (GSH) depletion activity of PtMn nanocubes consumed GSH with the assistance of Mn3+/Mn2+. Upon 808 nm laser irradiation, mild temperature due to the surface plasmon resonance effect of Pt metal can also enhance the Fenton reaction. Conclusion: PtMn nanocubes can not only destroy the antioxidant system via efficient reactive oxygen species generation and continuous GSH consumption but also propose the photothermal effect of noble metal for enhanced Fenton reaction activity.


Subject(s)
Glutathione , Manganese , Platinum , Reactive Oxygen Species , Animals , Platinum/chemistry , Platinum/pharmacology , Reactive Oxygen Species/metabolism , Glutathione/chemistry , Humans , Manganese/chemistry , Manganese/pharmacology , Photothermal Therapy/methods , Mice , Metal Nanoparticles/chemistry , Hydrogen Peroxide/chemistry , Cell Line, Tumor , Hydroxyl Radical/chemistry , Antineoplastic Agents/chemistry , Antineoplastic Agents/pharmacology , Iron/chemistry
7.
Biosens Bioelectron ; 261: 116468, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-38852326

ABSTRACT

Rational design of peroxidase (POD)-like nanozymes with high activity and specificity still faces a great challenge. Besides, the investigations of nanozymes inhibitors commonly focus on inhibition efficiency, the interaction between nanozymes-involved catalytic reactions and inhibitors is rarely reported. In this work, we design a p-block metal Sn-doped Pt (p-d/PtSn) nanozymes with the selective enhancement of POD-like activity. The p-d orbital hybridization interaction between Pt and Sn can effectively optimize the electronic structure of PtSn nanozymes and thus selectively enhance POD-like activity. In addition, the antioxidants as nanozymes inhibitors can effectively inhibit the POD-like activity of p-d/PtSn nanozymes, which results in the fact that antioxidants absorbed on the p-d/PtSn surface can hinder the adsorption of hydrogen peroxide. The inhibition type (glutathione as a model molecule) is reversible mixed-inhibition with inhibition constants (Ki' and Ki) of 0.21 mM and 0.03 mM. Finally, based on the varying inhibition levels of antioxidant molecules, a colorimetric sensor array is constructed to distinguish and simultaneously detect five antioxidants. This work is expected to design highly active and specific nanozymes through p-d orbital hybrid engineering, and also provides insights into the interaction between nanozymes and inhibitors.


Subject(s)
Antioxidants , Biosensing Techniques , Colorimetry , Platinum , Colorimetry/methods , Antioxidants/chemistry , Antioxidants/pharmacology , Antioxidants/analysis , Biosensing Techniques/methods , Platinum/chemistry , Peroxidase/chemistry , Hydrogen Peroxide/chemistry , Hydrogen Peroxide/analysis , Nanostructures/chemistry , Catalysis
8.
Anal Chem ; 96(26): 10686-10695, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38885608

ABSTRACT

Exploiting the multiple properties of nanozymes for the multimode lateral flow assay (LFA) is urgently required to improve the accuracy and versatility. Herein, we developed a novel plasmonic Au nanostar@PtOs nanocluster (Au@PtOs) as a multimode signal tag for LFA detection. Based on the PtOs bimetallic nanocluster doping strategy, Au@PtOs can indicate both excellent SERS enhancement and nanozyme catalytic activity. Meanwhile, Au@PtOs displays a better photothermal effect than that of Au nanostars. Therefore, catalytic colorimetric/SERS/temperature three-mode signals can be read out based on the Au@PtOs nanocomposite. The Au@PtOs was combined with LFA and applied for breast cancer exosome detection. The detection limit for the colorimetric/SERS/temperature mode was 2.6 × 103/4.1 × 101/4.6 × 102 exosomes/µL, respectively, which was much superior to the common Au nanoparticles LFA (∼105 exosomes/µL). Moreover, based on the fingerprint molecular recognition ability of the SERS mode, exosome phenotypes derived from different breast cancer cell lines can be discriminated easily. Based on the convenient visual colorimetric mode and sensitive SERS/temperature quantitative modes, Au@PtOs driven LFA can satisfy the requirements of accurate and flexible multimodal sensing in different application scenarios.


Subject(s)
Biosensing Techniques , Breast Neoplasms , Colorimetry , Exosomes , Gold , Spectrum Analysis, Raman , Humans , Gold/chemistry , Exosomes/chemistry , Biosensing Techniques/methods , Breast Neoplasms/diagnosis , Metal Nanoparticles/chemistry , Platinum/chemistry , Cell Line, Tumor , Limit of Detection , Female
9.
ACS Nano ; 18(26): 16853-16866, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38896491

ABSTRACT

The precise modulation of electrical activity in specific neuronal populations is paramount for rectifying abnormal neurological functions and is a critical element in the therapeutic arsenal for neurological disorders. However, achieving a balance between minimal invasiveness and robust neuroprotection poses a considerable challenge. Herein, we present a nanoneuromodulation strategy integrating neuroprotective features to effectively address epilepsy with minimal invasiveness and enable wireless functionality. Strategically engineered nanotransducer, adorned with platinum (Pt) decoration with titanium disulfide (TiS2) (TiS2/Pt), enables precise modulation of neuronal electrical activity in vitro and in vivo, ensuring exceptional temporal fidelity under millisecond-precision near-infrared (NIR) light pulses irradiation. Concurrently, TiS2/Pt showcase a pronounced enhancement in enzyme-mimicking activity, offering a robust defense against oxidative neurological injury in vitro. Nanotransducer-enabled wireless neuromodulation with biocatalytic neuroprotective capacity is highly effective in alleviating epileptic high-frequency neural activity and diminishing oxidative stress levels, thereby restoring redox equilibrium. This integrated therapeutic approach reduces the severity of epilepsy, demonstrating minimal invasiveness and obviating the requirements for genetic manipulation and optical fiber implantation, while providing an alternative avenue for neurological disorder treatment.


Subject(s)
Epilepsy , Epilepsy/therapy , Animals , Titanium/chemistry , Titanium/pharmacology , Platinum/chemistry , Platinum/pharmacology , Neuroprotective Agents/pharmacology , Neuroprotective Agents/chemistry , Neuroprotection/drug effects , Mice , Disulfides/chemistry , Disulfides/pharmacology , Oxidative Stress/drug effects , Humans , Neurons/drug effects , Neurons/metabolism , Infrared Rays , Rats
10.
Anal Chem ; 96(24): 9909-9916, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38830056

ABSTRACT

The development of the Point-of-Care Testing (POCT) platform that combines convenience and cost-effectiveness is crucial for enabling the visual detection of disease biomarkers. In this work, a POCT platform for the sensitive in situ detection of prostate specific antigen (PSA) with dual-signal output was constructed by functionalizing the Eppendorf (EP) tube. This was achieved through the modification of aptamer hairpin probes (AHPs) on the lid of the EP tube and the assembly of a nanoenzyme hydrogel film on its inner wall. The target could trigger the release of Ag+ by AHP and subsequently activate Ag+-dependent DNAzyme (Ag-DNAzyme). This would initiate the cleavage of the DNA-Au/Pt NP hydrogel network, leading to the release of Au/Pt NPs. The released Au/Pt NPs exhibit both peroxidase (POD)-like and catalase (CAT)-like activity to produce a colorimetric response and induce liquid flow under pressure. Therefore, the target can be measured visually and quantitatively through colorimetric analysis and the measurement of total dissolved solids (TDS) using a pressure-triggered liquid flow device integrated into the platform. The designed platform is distinguished by its simplicity, specificity, cost-effectiveness, and remarkable sensitivity. It allows for the visual detection of PSA within concentration ranges of 0.5-100 ng/L (colorimetric) and 3-100 ng/L (TDS reading), boasting detection limits as low as 0.15 ng/L (colorimetric) and 0.57 ng/L (TDS reading). The strategy of target-triggered nanoenzyme release significantly enhances sensitivity and provides a guiding approach for visual biomarker detection.


Subject(s)
Aptamers, Nucleotide , Colorimetry , DNA, Catalytic , Gold , Metal Nanoparticles , Point-of-Care Testing , Prostate-Specific Antigen , Prostate-Specific Antigen/analysis , Humans , Gold/chemistry , DNA, Catalytic/chemistry , DNA, Catalytic/metabolism , Metal Nanoparticles/chemistry , Aptamers, Nucleotide/chemistry , Platinum/chemistry , Hydrogels/chemistry , Biosensing Techniques , Silver/chemistry , Limit of Detection
11.
Chemosphere ; 361: 142517, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38830464

ABSTRACT

Indoor volatile formaldehyde is a serious health hazard. The development of low-temperature and efficient nonhomogeneous oxidation catalysts is crucial for protecting human health and the environment but is also quite challenging. Single-atom catalysts (SACs) with active centers and coordination environments that are precisely tunable at the atomic level exhibit excellent catalytic activity in many catalytic fields. Among two-dimensional materials, the nonmagnetic monolayer material g-C3N4 may be a good platform for loading single atoms. In this study, the effect of nitrogen defect formation on the charge distribution of g-C3N4 is discussed in detail using density functional theory (DFT) calculations. The effect of nitrogen defects on the activated molecular oxygen of Pt/C3N4 was systematically revealed by DFT calculations in combination with molecular orbital theory. Two typical reaction mechanisms for the catalytic oxidation of formaldehyde were proposed based on the Eley-Rideal (E-R) mechanism. Pt/C3N4-V3N was more advantageous for path 1, as determined by the activation energy barrier of the rate-determining step and product desorption. Finally, the active centers and chemical structures of Pt/C3N4 and Pt/C3N4-V3N were verified to have good stability at 375 K by determination of the migration energy barriers and ab initio molecular dynamics simulations. Therefore, the formation of N defects can effectively anchor single-atom Pt and provide additional active sites, which in turn activate molecular oxygen to efficiently catalyze the oxidation of formaldehyde. This study provides a better understanding of the mechanism of formaldehyde oxidation by single-atom Pt catalysts and a new idea for the development of Pt as well as other metal-based single-atom oxidation catalysts.


Subject(s)
Density Functional Theory , Formaldehyde , Oxidation-Reduction , Platinum , Formaldehyde/chemistry , Catalysis , Platinum/chemistry , Nitrogen Compounds/chemistry , Molecular Dynamics Simulation , Oxygen/chemistry , Graphite
12.
Mikrochim Acta ; 191(7): 407, 2024 06 19.
Article in English | MEDLINE | ID: mdl-38898338

ABSTRACT

A smartphone-based electrochemical aptasensing platform was developed for the point-of-care testing (POCT) of carcinoembryonic antigen (CEA) based on the ferrocene (Fc) and PdPt@PCN-224 dual-signal labeled strategy. The prepared PdPt@PCN-224 nanocomposite showed a strong catalytic property for the reduction of H2O2. Phosphate group-labeled aptamer could capture PdPt@PCN-224 by Zr-O-P bonds to form PdPt@PCN-224-P-Apt. Therefore, a dual signal labeled probe was formed by the hybridization between Fc-DNA and PdPt@PCN-224-P-Apt. The presence of CEA forced PdPt@PCN-224-P-Apt to leave the electrode surface due to the specific affinity, leading to the decrease of the reduction current of H2O2. At the same time, the Fc-DNA strand changed to hairpin structure, which made Fc closer to the electrode and resulted in the increase of the oxidation current of Fc. Thus, CEA can be accurately determined through both signals: the decrease of H2O2 reduction current and the increase of Fc oxidation current, which could avoid the false positive signal. Under the optimal conditions, the prepared aptasensor exhibited a wide linear range from 1 pg·mL-1 to 100 ng·mL-1 and low detection limits of 0.98 pg·mL-1 and 0.27 pg·mL-1 with Fc and PdPt@PCN-224 as signal labels, respectively. The aptasensor developed in this study has successfully demonstrated its capability to detect CEA in real human serum samples. These findings suggest that the proposed sensing platform will hold great potential for clinical tumor diagnosis and monitoring.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Carcinoembryonic Antigen , Electrochemical Techniques , Ferrous Compounds , Hydrogen Peroxide , Limit of Detection , Palladium , Point-of-Care Testing , Smartphone , Carcinoembryonic Antigen/blood , Carcinoembryonic Antigen/analysis , Aptamers, Nucleotide/chemistry , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Humans , Biosensing Techniques/methods , Hydrogen Peroxide/chemistry , Palladium/chemistry , Ferrous Compounds/chemistry , Metallocenes/chemistry , Platinum/chemistry
13.
Int J Mol Sci ; 25(12)2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38928230

ABSTRACT

Monofunctional platinum complexes offer a promising alternative to cisplatin in cancer chemotherapy, showing a unique mechanism of action. Their ability to induce minor helix distortions effectively inhibits DNA transcription. In our study, we synthesized and characterized three monofunctional Pt(II) complexes with the general formula [Pt(en)(L)Cl]NO3, where en = ethylenediamine, and L = pyridine (py), 2-methylpyridine (2-mepy), and 2-phenylpyridine (2-phpy). The hydrolysis rates of [Pt(en)(py)Cl]NO3 (1) and [Pt(en)(2-mepy)Cl]NO3 (2) decrease with the bulkiness of the auxiliary ligand with k(1) = 2.28 ± 0.15 × 10-4 s-1 and k(2) = 8.69 ± 0.98 × 10-5 s-1 at 298 K. The complex [Pt(en)(2-phpy)Cl]Cl (3) demonstrated distinct behavior. Upon hydrolysis, an equilibrium (Keq = 0.385 mM) between the complexes [Pt(en)(2-phpy)Cl]+ and [Pt(en)(2-phpy-H+)]+ was observed with no evidence (NMR or HR-ESI-MS) for the presence of the aquated complex [Pt(en)(2-phpy)(H2O)]2+. Despite the kinetic similarities between phenanthriplatin and (2), complexes (1) and (2) exhibit minimal activity against A549 lung cancer cell line (IC50 > 100 µΜ), whereas complex (3) exhibits notable cytotoxicity (IC50 = 41.11 ± 2.1 µΜ). In examining the DNA binding of (1) and (2) to the DNA model guanosine (guo), we validated their binding through guoN7, which led to an increased population of the C3'-endo sugar conformation, as expected. However, we observed that the rapid transition 2E (C2'-endo) ↔ 3E (C3'-endo), in the case of [Pt(en)(py)(guo)](NO3)2 ([1-guo]), slows down in the case of [Pt(en)(2-mepy)(guo)](NO3)2 ([2-guo]), resulting in separate signals for the two conformers in the 1H NMR spectra. This phenomenon arises from the steric hindrance between the methyl group of pyridine and the sugar moiety of guanosine. Notably, this hindrance is absent in [2-(9-MeG)] (9-MeG = 9-methylguanine), probably due to the absence of a bulky sugar unit in 9-MeG. In the case of (3), where the bulkiness of the substitution on the pyridine is further increased by a phenyl group, we observed a notable proximity between 9-MeGH8 and the phenyl ring of 2-phpy. Considering that only (3) exhibited good cytotoxicity against the A549 cancer cell line, it is suggested that auxiliary ligands, L, with an extended aromatic system and proper orientation in complexes of the type cis-[Pt(en)(L)Cl]NO3, may enhance the cytotoxic activity of such complexes.


Subject(s)
Antineoplastic Agents , DNA , Antineoplastic Agents/pharmacology , Antineoplastic Agents/chemistry , DNA/chemistry , DNA/metabolism , Humans , Ligands , Organoplatinum Compounds/pharmacology , Organoplatinum Compounds/chemistry , Organoplatinum Compounds/chemical synthesis , Cell Line, Tumor , Hydrolysis , Platinum/chemistry , Platinum/pharmacology , A549 Cells
14.
ACS Nano ; 18(25): 16113-16125, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38857428

ABSTRACT

Urinary extracellular vesicles (uEVs) are regarded as highly promising liquid-biopsy biomarkers for the early diagnosis and prognosis of bladder cancer (BC). However, detection of uEVs remains technically challenging owing to their huge heterogeneity and ultralow abundance in real samples. We herein present a choline phosphate-grafted platinum nanozyme (Pt@CP) that acts as a universal EV probe for the construction of a high-throughput and high-sensitivity immunoassay, which allowed multiplex profiling of uEV protein markers for BC detection. With the Pt@CP-based immunoassays, three uEV protein markers (MUC-1, CCDC25, and GLUT1) were identified for BC, by which the BC cases (n = 48), cystitis patients (n = 27), and healthy donors (n = 24) were discriminated with high clinical sensitivity and specificity (area under curve = 98.3%). For the BC cases (n = 9) after surgery, the Pt@CP-based immunoassay could report the postoperative residual tumor that cannot be observed by cystoscopy, which is clinically significant for assessing BC recurrence. This work provides generally high sensitivity for EV detection, facilitating the discovery and clinical use of EV-based biomarkers.


Subject(s)
Biomarkers, Tumor , Extracellular Vesicles , Urinary Bladder Neoplasms , Urinary Bladder Neoplasms/diagnosis , Urinary Bladder Neoplasms/pathology , Humans , Extracellular Vesicles/chemistry , Biomarkers, Tumor/analysis , Phosphorylcholine/chemistry , Immunoassay/methods , Platinum/chemistry , Female
15.
Anal Chem ; 96(25): 10467-10475, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38863336

ABSTRACT

"Signal-off" nanozyme sensing platforms are usually employed to detect analytes (e.g., ascorbic acid (AA) and alkaline phosphatase (ALP)), which are mostly based on oxidase (OXD) nanozymes. However, their drawbacks, like dissolved oxygen-dependent catalysis capability, relatively low enzyme activity, limited amount, and kind, may not favor sensing platforms' optimization. Meanwhile, with the need for sustainable development, a reusable "signal-off" sensing platform is essential for cutting down the cost of the assay, but it is rarely developed in previous studies. Magnetic peroxidase (POD) nanozymes potentially make up the deficiencies and become reusable and better "signal-off" sensing platforms. As a proof of concept, we first construct Fe3O4@polydopamine-supported Pt/Ru alloy nanoparticles (IOP@Pt/Ru) without stabilizers. IOP@Pt/Ru shows high POD activity with Vmax of 83.24 × 10-8 M·s-1 for 3,3',5,5'-Tetramethylbenzidine (TMB) oxidation. Meanwhile, its oxidation rate for TMB is slower than the reduction of oxidized TMB by reducers, favorable for a more significant detection signal. On the other hand, IOP@Pt/Ru possesses great magnet-responsive capability, making itself be recycled and reused for at least 15-round catalysis. When applying IOP@Pt/Ru for AA (ALP) detection, it performs better detectable adaptability, with a linear range of 0.01-0.2 mM (0.1-100 U/L) and a limit of detection of 0.01 mM (0.05 U/L), superior to most of OXD nanozyme-based ALP sensing platform. Finally, IOP@Pt/Ru's reusable assay was demonstrated in real blood samples for ALP assay, which has never been explored in previous studies. Overall, this study develops a reusable "signal-off" nanozyme sensing platform with superior assay capabilities than traditional OXD nanozymes, paves a new way to optimize nanozyme-based "signal-off" sensing platforms, and provides an idea for constructing inexpensive and sustainable sensing platforms.


Subject(s)
Alloys , Peroxidase , Platinum , Platinum/chemistry , Alloys/chemistry , Peroxidase/chemistry , Peroxidase/metabolism , Benzidines/chemistry , Limit of Detection , Oxidation-Reduction , Polymers/chemistry , Humans , Catalysis , Biosensing Techniques/methods , Ascorbic Acid/analysis , Ascorbic Acid/chemistry , Indoles
16.
ACS Sens ; 9(6): 2877-2887, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38779969

ABSTRACT

Precise assessment of wakefulness states during sevoflurane anesthesia and timely arousal are of paramount importance to refine the control of anesthesia. To tackle this issue, a bidirectional implantable microelectrode array (MEA) is designed with the capability to detect electrophysiological signal and perform in situ deep brain stimulation (DBS) within the dorsomedial hypothalamus (DMH) of mice. The MEA, modified with platinum nanoparticles/IrOx nanocomposites, exhibits exceptional characteristics, featuring low impedance, minimal phase delay, substantial charge storage capacity, high double-layer capacitance, and longer in vivo lifetime, thereby enhancing the sensitivity of spike firing detection and electrical stimulation (ES) effectiveness. Using this MEA, sevoflurane-inhibited neurons and sevoflurane-excited neurons, together with changes in the oscillation characteristics of the local field potential within the DMH, are revealed as indicative markers of arousal states. During the arousal period, varying-frequency ESs are applied to the DMH, eliciting distinct arousal effects. Through in situ detection and stimulation, the disparity between these outcomes can be attributed to the influence of DBS on different neurons. These advancements may further our understanding of neural circuits and their potential applications in clinical contexts.


Subject(s)
Deep Brain Stimulation , Microelectrodes , Sevoflurane , Animals , Sevoflurane/pharmacology , Mice , Deep Brain Stimulation/instrumentation , Neurons/drug effects , Neurons/physiology , Male , Anesthetics, Inhalation , Electric Stimulation , Platinum/chemistry , Mice, Inbred C57BL
17.
ACS Sens ; 9(5): 2645-2652, 2024 05 24.
Article in English | MEDLINE | ID: mdl-38709872

ABSTRACT

In this work, we present the development of the first implantable aptamer-based platinum microelectrode for continuous measurement of a nonelectroactive molecule, neuropeptide Y (NPY). The aptamer immobilization was performed via conjugation chemistry and characterized using cyclic voltammetry before and after the surface modification. The redox label, methylene blue (MB), was attached at the end of the aptamer sequence and characterized using square wave voltammetry (SWV). NPY standard solutions in a three-electrode cell were used to test three aptamers in steady-state measurement using SWV for optimization. The aptamer with the best performance in the steady-state measurements was chosen, and continuous measurements were performed in a flow cell system using intermittent pulse amperometry. Dynamic measurements were compared against confounding and similar peptides such as pancreatic polypeptide and peptide YY, as well as somatostatin to determine the selectivity in the same modified microelectrode. Our Pt-microelectrode aptamer-based NPY biosensor provides signals 10 times higher for NPY compared to the confounding molecules. This proof-of-concept shows the first potential implantable microelectrode that is selectively sensitive to NPY concentration changes.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Microelectrodes , Neuropeptide Y , Platinum , Neuropeptide Y/analysis , Biosensing Techniques/methods , Platinum/chemistry , Aptamers, Nucleotide/chemistry , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation
18.
Environ Sci Pollut Res Int ; 31(25): 37746-37756, 2024 May.
Article in English | MEDLINE | ID: mdl-38787474

ABSTRACT

The selective catalytic oxidation (SCO) is an effective method for removing slipped high-concentration ammonia from NH3-fueled engine exhaust gas. Herein a novel bifunctional catalyst was synthesized by mechanically mixing sulfated Ce/ZrO2 (Ce/ZrO2-S) with a small fraction of Pt/Al2O3 (Pt 0.1 wt.%) for SCO of NH3. As expected, the introduction of a small amount of Pt/Al2O3 significantly improved NH3 conversion ability of Ce/ZrO2-S catalysts toward low-temperature direction. When the mass ratio of Pt/Al2O3 to Ce/ZrO2-S was 7.5% (the corresponding mixed catalyst was denoted as P@CZS-7.5), T90 temperature was 312 °C. More importantly, P@CZS-7.5 catalyst exhibited a much better N2 selectivity (> 96%) in a wide temperature range (320 ~ 450 °C). H2-TPR results revealed that the addition of a trace amount of Pt/Al2O3 significantly led to a distinct shift of reduction temperature peak toward low-temperature direction, thereby greatly improved the low-temperature redox performance of mixed catalysts. Furthermore, NH3-TPD and BET results showed that P@CZS-7.5 catalyst exhibited a similar NH3 adsorption capacity to Ce/ZrO2-S catalyst, while the former had a relatively higher specific surface area than the latter. It was considered as a crucial factor for P@CZS-7.5 catalyst maintaining superior N2 selectivity in high-concentration NH3 (5000 ppm) removal processes. In situ DRIFTS results indicated that P@CZS-7.5 catalyst followed the internal selective catalytic reduction (i-SCR) mechanism in NH3-SCO reactions.


Subject(s)
Aluminum Oxide , Ammonia , Oxidation-Reduction , Ammonia/chemistry , Catalysis , Aluminum Oxide/chemistry , Platinum/chemistry , Zirconium/chemistry
19.
Anal Chim Acta ; 1309: 342698, 2024 Jun 22.
Article in English | MEDLINE | ID: mdl-38772661

ABSTRACT

BACKGROUND: The lateral flow immunoassay (LFIA) is widely employed as a point-of-care testing (POCT) technique. However, its limited sensitivity hinders its application in detecting biomarkers with low abundance. Recently, the utilization of nanozymes has been implemented to enhance the sensitivity of LFIA by catalyzing the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB). The catalytic performance of nanozymes plays a crucial role in influencing the sensitivity of LFIA. RESULTS: The Cornus officinalis Sieb. et Zucc-Pd@Pt (CO-Pd@Pt) nanozyme with good peroxidase-like activity was synthesized herein through a facile one-pot method employing Cornus officinalis Sieb. et Zucc extract as a reducing agent. The morphology and composition of the CO-Pd@Pt nanozyme were characterized using TEM, SEM, XRD, and XPS. As a proof of concept, the as-synthesized CO-Pd@Pt nanozyme was utilized in LFIA (CO-Pd@Pt-LFIA) for the detection of human chorionic gonadotropin (hCG). Compared to conventional gold nanoparticles-based LFIA (AuNPs-LFIA), CO-Pd@Pt-LFIA demonstrated a significant enhancement in the limit of detection (LOD, 0.08 mIU/mL), which is approximately 160 times lower than that of AuNPs-LFIA. Furthermore, experiments evaluating accuracy, precision, selectivity, interference, and stability have confirmed the practical applicability of CO-Pd@Pt-LFIA for hCG content determination. SIGNIFICANCE: The present study presents a novel approach for the synthesis of bimetallic nanozymes through environmentally friendly methods, utilizing plant extracts as both protective and reducing agents. Additionally, an easily implementable technique is proposed to enhance signal detection in lateral flow immunoassays.


Subject(s)
Palladium , Platinum , Palladium/chemistry , Platinum/chemistry , Immunoassay/methods , Humans , Metal Nanoparticles/chemistry , Limit of Detection , Peroxidase/chemistry , Peroxidase/metabolism , Benzidines/chemistry , Catalysis , Oxidation-Reduction
20.
ACS Appl Mater Interfaces ; 16(20): 25601-25609, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38727578

ABSTRACT

We report an ultrasensitive sandwich-type electrochemical immunosensor to detect the breast cancer biomarker CA 15-3. Amine-functionalized composite of reduced graphene oxide and Fe3O4 nanoparticles (MRGO-NH2) was used as an electrochemical sensing platform material to modify the electrodes. The nanocomposite comprising Pt and Fe3O4 nanoparticles (NPs) anchored on multiwalled carbon nanotubes (Pt-Fe3O4-MWCNTs-NH2) was utilized as a pseudoenzymatic signal-amplifying label. Compared to reduced graphene oxide, the composite MRGO-NH2 platform material demonstrated a higher electrochemical signal. In the Pt-Fe3O4-MWCNTs-NH2 label, multiwalled carbon nanotubes provided the substratum to anchor abundant catalytic Pt and Fe3O4 NPs. The nanocomposites were thoroughly characterized using transmission electron microscopy, Fourier transform infrared spectroscopy, X-ray diffraction, scanning electron microscopy, and X-ray photoelectron spectroscopy. An electroanalytical study and prevalidation of the immunosensor was carried out. The immunosensor exhibited exceptional capabilities in detecting CA 15-3, offering a wider linear range of 0.0005-100 U mL-1 and a lower detection limit of 0.00008 U mL-1. Moreover, the designed immunosensor showed good specificity, reproducibility, and acceptable stability. The sensor was successfully applied to analyze samples from breast cancer patients, yielding reliable results.


Subject(s)
Biomarkers, Tumor , Breast Neoplasms , Electrochemical Techniques , Nanocomposites , Nanotubes, Carbon , Platinum , Humans , Nanotubes, Carbon/chemistry , Breast Neoplasms/diagnosis , Nanocomposites/chemistry , Electrochemical Techniques/methods , Biomarkers, Tumor/analysis , Biomarkers, Tumor/blood , Female , Platinum/chemistry , Biosensing Techniques/methods , Graphite/chemistry , Amines/chemistry , Mucin-1/analysis , Mucin-1/blood , Immunoassay/methods , Limit of Detection
SELECTION OF CITATIONS
SEARCH DETAIL
...