World J Urol ; 42(1): 391, 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-38985294

ABSTRACT

PURPOSE: To compare the lifespan of first transcorporal cuff (TC) placement of an artificial urinary sphincter (AUS) versus standard placement (SP) in patients with prior radiotherapy (RT) for prostate cancer (PCa). METHODS: We reviewed first (virgin) AUS placements from two high-volume care centers between 1/2011 and 1/2021, including PCa patients with RT history. AUS lifespan was assessed via the hazard ratio of device explantation and/or revision within a ten-year timeframe for the TC vs. SP approaches. Chi-square, Fisher's exact, and t-tests compared clinicodemographic variables. Kaplan-Meier curve compared TC and SP lifespan. RESULTS: 85/314 men with AUS met inclusion criteria, with 38.8% (33/85) in the TC group and 61.2% (52/85) in the SP group. Median ages were 69.8 (IQR = 65.2-73.6) and 67.1 (61.6-72.9), respectively, p = 0.17. Over a median follow up of 51.9 (15.8-86.1) and 80.4 (28.1-128.3) months for the TC and SP, overall, 12 (36.4%) TC devices were removed (four [12.1%] due to mechanical failures; eight [24.2%] erosions, and two [6.1%] infections) vs. 29 (55.8%) in the SP group (14 [26.9%] mechanical failures; 11 [21.1%] erosions, and five [9.6%] infections). No statistically significant differences were observed between the two approaches, with HR = 0.717, 95% CI 0.37-1.44, p = 0.35. The calculated device survival probabilities for the TC vs. SP at one, five, and 10 years were 78.8% vs. 76.9%, 69.3% vs. 58.7%, and 62.1% vs. 46.7%, respectively. CONCLUSIONS: TC cuff insertion for the first AUS implantation in pre-radiated patients showed to be comparable to SP when it comes to device survival, with comparable complication rates. Current guidance for approach selection is primarily based on patient selection and surgeon preference.


Subject(s)
Prostatic Neoplasms , Urinary Sphincter, Artificial , Humans , Male , Aged , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/surgery , Middle Aged , Retrospective Studies , Prosthesis Implantation/methods , Time Factors , Prosthesis Failure
4.
BMC Ophthalmol ; 24(1): 248, 2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38862946

ABSTRACT

BACKGROUND: Ahmed valve implantation demonstrated an increasing proportion in glaucoma surgery, but predicting the successful maintenance of target intraocular pressure remains a challenging task. This study aimed to evaluate the performance of machine learning (ML) in predicting surgical outcomes after Ahmed valve implantation and to assess potential risk factors associated with surgical failure to contribute to improving the success rate. METHODS: This study used preoperative data of patients who underwent Ahmed valve implantation from 2017 to 2021 at Ajou University Hospital. These datasets included demographic and ophthalmic parameters (dataset A), systemic medical records excluding psychiatric records (dataset B), and psychiatric medications (dataset C). Logistic regression, extreme gradient boosting (XGBoost), and support vector machines were first evaluated using only dataset A. The algorithm with the best performance was selected based on the area under the receiver operating characteristics curve (AUROC). Finally, three additional prediction models were developed using the best performance algorithm, incorporating combinations of multiple datasets to predict surgical outcomes at 1 year. RESULTS: Among 153 eyes of 133 patients, 131 (85.6%) and 22 (14.4%) eyes were categorized as the success and failure groups, respectively. The XGBoost was shown as the best-performance model with an AUROC value of 0.684, using only dataset A. The final three further prediction models were developed based on the combination of multiple datasets using the XGBoost model. All datasets combinations demonstrated the best performances in terms of AUROC (dataset A + B: 0.782; A + C: 0.773; A + B + C: 0.801). Furthermore, advancing age was a risk factor associated with a higher surgical failure incidence. CONCLUSIONS: ML provides some predictive value in predicting the outcomes of Ahmed valve implantation at 1 year. ML evaluation revealed advancing age as a common risk factor for surgical failure.


Subject(s)
Glaucoma Drainage Implants , Glaucoma , Intraocular Pressure , Machine Learning , Humans , Female , Male , Glaucoma/surgery , Glaucoma/physiopathology , Intraocular Pressure/physiology , Middle Aged , Aged , Retrospective Studies , ROC Curve , Adult , Prosthesis Implantation/methods , Risk Factors , Visual Acuity/physiology , Treatment Outcome , Aged, 80 and over
5.
BMC Musculoskelet Disord ; 25(1): 474, 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38880911

ABSTRACT

BACKGROUND: The treatment of infected bone defects remains a clinical challenge. With the development of three-dimensional printing technology, three-dimensional printed implants have been used for defect reconstruction. The aim of this study was to investigate the clinical outcomes of three-dimensional printed porous prosthesis in the treatment of femoral defects caused by osteomyelitis. METHODS: Eleven patients with femoral bone defects following osteomyelitis who were treated with 3D-printed porous prosthesis at our institution between May 2017 and July 2021, were included. Eight patients were diagnosed with critical-sized defects, and the other three patients were diagnosed with shape-structural defects. A two-stage procedure was performed for all patients, and the infection was eradicated and bone defects were occupied by polymethylmethacrylate spacer during the first stage. The 3D-printed prosthesis was designed and used for the reconstruction of femoral defects in the second stage. Position of the reconstructed prostheses and bone growth were measured using radiography. The union rate, complications, and functional outcomes at the final follow-up were assessed. RESULTS: The mean length of the bone defect was 14.0 cm, union was achieved in 10 (91%) patients. All patients showed good functional performance at the most recent follow-up. In the critical-sized defect group, one patient developed a deep infection that required additional procedures. Two patients had prosthetic dislocations. Radiography demonstrated good osseous integration of the implant-bone interface in 10 patients. CONCLUSION: The 3D printed prostheses enable rapid anatomical and mechanically stable reconstruction of extreme femur bone defects, effectively shortens treatment time, and achieves satisfactory clinical outcomes.


Subject(s)
Femur , Osteomyelitis , Printing, Three-Dimensional , Prosthesis Design , Titanium , Humans , Osteomyelitis/surgery , Osteomyelitis/etiology , Osteomyelitis/diagnostic imaging , Male , Female , Femur/surgery , Femur/diagnostic imaging , Middle Aged , Adult , Porosity , Treatment Outcome , Prosthesis Implantation/instrumentation , Prosthesis Implantation/methods , Prosthesis Implantation/adverse effects , Retrospective Studies , Aged , Young Adult , Plastic Surgery Procedures/methods , Plastic Surgery Procedures/instrumentation
6.
BMC Ophthalmol ; 24(1): 264, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38902667

ABSTRACT

BACKGROUND: Minimally invasive bleb surgery using the XEN-45 gel stent has not been established for the treatment of normal-tension glaucoma (NTG). The main objective of this study was to evaluate the long-term treatment efficacy and safety of XEN-45 in eyes with uncontrolled NTG. METHODS: A retrospective analysis of patients with NTG who underwent XEN-45 gel stent implantation at university hospital Tuebingen between 2016 and 2021. The primary outcome measure was surgical success after three years defined as lowering of intraocular pressure (IOP) of ≥ 20%, with target IOP between 6 and 15 mmHg. Success was complete without and qualified irrespective of topical antiglaucoma medication use. The need for further glaucoma surgery, except for needling, was regarded as a failure. The secondary outcome measures included changes in mean IOP, number of antiglaucoma medications, and needling and complication rates. RESULTS: Twenty-eight eyes from 23 patients were included in the final analysis. Complete and qualified success rates were 56.5% and 75% after three years, respectively. Mean postoperative IOP ± standard deviation decreased significantly after three years from 19.3 ± 2.0 mmHg at baseline to 13.7 ± 4.2 mmHg (n = 22; p < 0.0001). The median number of antiglaucoma medications decreased from 2 (range 0-4) to 0 after three years (range 0-3; p < 0.0001). Sixteen eyes (57%) required a median of 1 (range 1-3) needling procedures. One eye required further glaucoma surgery. No sight-threatening complications were observed. CONCLUSION: The XEN-45 stent is effective and safe for the long-term treatment of NTG. However, needling was frequently required to improve outcomes.


Subject(s)
Glaucoma Drainage Implants , Intraocular Pressure , Low Tension Glaucoma , Stents , Humans , Male , Female , Retrospective Studies , Intraocular Pressure/physiology , Low Tension Glaucoma/surgery , Low Tension Glaucoma/physiopathology , Aged , Middle Aged , Treatment Outcome , Follow-Up Studies , Visual Acuity/physiology , Prosthesis Design , Prosthesis Implantation/methods , Aged, 80 and over
7.
Int Ophthalmol ; 44(1): 243, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38904834

ABSTRACT

PURPOSE: To describe the outcomes of double implantation of Xen 45 Gel Stent (Xen) using an ab externo approach with closed conjunctiva. METHODS: Retrospective single-centre case series of primary open-angle glaucoma patients with at least six months of follow-up after implantation of a second Xen in the same eye via ab externo technique without conjunctival opening. RESULTS: Eight pseudophakic eyes of 8 patients were included. Intraocular pressure (IOP) dropped from 30 ± 2.6 mmHg pre-operatively to 22.4 ± 2.3 mmHg one month after the first Xen implant (mean difference: -7.6 mmHg [95% confidence interval: -9.4, -5.9 mmHg], p = 0.0092). A second Xen was then implanted to achieve the target IOP. The procedure showed no significant intraoperative or postoperative complications. The IOP dropped to 16.1 ± 2.7 mmHg six months following this second implant (mean difference: -6.3 mmHg [95% confidence interval: -7.2, -5.3 mmHg], p = 0.0183); however, 3 patients needed medical therapy to further reduce the IOP towards the target value. CONCLUSION: Sequential implantation of two Xen 45 Gel Stents using an ab externo approach with closed conjunctiva appears a promising procedure that showed a favorable safety and efficacy profile in this small case series. This pilot data might pave the way for further studies to evaluate the safety and efficacy of the procedure.


Subject(s)
Glaucoma Drainage Implants , Glaucoma, Open-Angle , Intraocular Pressure , Prosthesis Design , Stents , Humans , Glaucoma, Open-Angle/surgery , Glaucoma, Open-Angle/physiopathology , Pilot Projects , Male , Female , Retrospective Studies , Intraocular Pressure/physiology , Aged , Middle Aged , Follow-Up Studies , Treatment Outcome , Prosthesis Implantation/methods , Aged, 80 and over , Visual Acuity
8.
J Robot Surg ; 18(1): 264, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38916783

ABSTRACT

Upper hemi-sternotomy is a common approach for outflow graft anastomosis to the ascending aorta in minimally invasive left-ventricular assist device implantation. Right mini-thoracotomy may also be used, but use of robotic assistance has been reported only anecdotally. The aim of our study was to confirm the feasibility of robotically assisted suturing of the outflow graft anastomosis and to assess performance metrics for the robotic suturing part of the procedure. The procedure was carried out in eight cadaver studies by two surgeons. The assist device pump head was inserted through a left-sided mini-thoracotomy and the outflow graft was passed toward a right-sided second interspace mini-thoracotomy through the pericardium. After placement of a partial occlusion clamp on the ascending aorta, a longitudinal aortotomy was performed and the outflow graft to ascending aorta anastomosis was carried out robotically. The procedure was feasible in all eight attempts. The mean outflow graft anastomotic time was 20.1 (SD 6.8) min and the mean surgeon confidence and comfort levels to complete the anastomoses were 8.3 (SD 2.4) and 6.9 (SD2.2), respectively, on a ten-grade Likert scale. On open inspection of the anastomoses, there was good suture alignment in all cases. We conclude that suturing of a left-ventricular assist device outflow graft to the human ascending aorta is very feasible with good surgeon comfort. Anastomotic times are acceptable and suture placement can be performed with appropriate alignment.


Subject(s)
Anastomosis, Surgical , Cadaver , Feasibility Studies , Heart-Assist Devices , Minimally Invasive Surgical Procedures , Operative Time , Robotic Surgical Procedures , Humans , Robotic Surgical Procedures/methods , Robotic Surgical Procedures/instrumentation , Anastomosis, Surgical/methods , Minimally Invasive Surgical Procedures/methods , Aorta/surgery , Surgeons , Suture Techniques , Prosthesis Implantation/methods , Thoracotomy/methods
9.
Isr Med Assoc J ; 26(5): 278-282, 2024 May.
Article in English | MEDLINE | ID: mdl-38736341

ABSTRACT

BACKGROUND: Long-term support with a HeartMate 3 (HM3) left ventricular assist device (LVAD) has improved outcomes of patients with end-stage heart failure. However, there is a paucity of data on the outcomes of patients who underwent concomitant cardiac surgical procedure (CCSP) during HM3-LVAD implantation. OBJECTIVES: To assess our single-center experience with patients who underwent CCSP during the implantation of an HM3-LVAD. METHODS: From December 2016 until April 2022, 131 adult patients underwent HM3-LVAD implantation. A total of 23 patients underwent CCSP during the HM3-LVAD implantation+CCSP, and 108 underwent only HM3-LVAD implantation (HM3-only). RESULTS: The median age was 59 ± 11 years (range 54-67), 82% (n=108) were male, and 76% (n=100) were implanted as a bridge-to-transplant. The concomitant procedures performed during the implantation included 8 aortic valve repairs/replacements, 14 tricuspid valve repairs, 4 patent foramen ovales or atrial septal defect closures, and 3 other cardiac procedures. The mean cardiopulmonary bypass time was 113 ± 58 minutes for the HM3-only group and 155 ± 47 minutes for the HM3+CCSP group (P = 0.007). The mortality rates at 30 days, 6 months, and 12 months post-implantation were 2 (9%), 5 (22%), and 6 (26%) respectively for the HM3+CCSP group, and 7 (6%), 18 (17%), and 30 (28%) for the HM3-only group (P = 0.658, 0.554, and 1.000). CONCLUSIONS: Our experience demonstrated no significant difference in the 30-day, 6-month, and 12-month mortality rates for patients who underwent a CCSP during HM3-LVAD implantation compared to patients who did not undergo CCSP during HM3-LVAD implantation.


Subject(s)
Cardiac Surgical Procedures , Heart Failure , Heart-Assist Devices , Humans , Heart-Assist Devices/statistics & numerical data , Male , Female , Middle Aged , Heart Failure/surgery , Heart Failure/mortality , Heart Failure/therapy , Aged , Cardiac Surgical Procedures/methods , Retrospective Studies , Treatment Outcome , Prosthesis Implantation/methods
10.
J Orthop Surg Res ; 19(1): 273, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38698477

ABSTRACT

BACKGROUND: Talar malignant tumor is extremely rare. Currently, there are several alternative management options for talus malignant tumor including below-knee amputation, tibio-calcaneal arthrodesis, and homogenous bone transplant while their shortcomings limited the clinical application. Three-dimensional (3D) printed total talus prosthesis in talus lesion was reported as a useful method to reconstruct talus, however, most researches are case reports and its clinical effect remains unclear. Therefore, the current study was to explore the application of 3D printed custom-made modular prosthesis in talus malignant tumor. METHODS: We retrospectively analyzed the patients who received the 3D printed custom-made modular prosthesis treatment due to talus malignant tumor in our hospital from February 2016 to December 2021. The patient's clinical data such as oncology outcome, operation time, and volume of blood loss were recorded. The limb function was evaluated with the Musculoskeletal Tumor Society 93 (MSTS-93) score, The American Orthopedic Foot and Ankle Society (AOFAS) score; the ankle joint ranges of motion as well as the leg length discrepancy were evaluated. Plain radiography and Tomosynthesis-Shimadzu Metal Artefact Reduction Technology (T-SMART) were used to evaluate the position of prosthesis and the osseointegration. Postoperative complications were recorded. RESULTS: The average patients' age and the follow-up period were respectively 31.5 ± 13.1 years; and 54.8 months (range 26-72). The medium operation time was 2.4 ± 0.5 h; the intraoperative blood loss was 131.7 ± 121.4 ml. The mean MSTS-93 and AOFAS score was 26.8 and 88.5 respectively. The average plantar flexion, dorsiflexion, varus, and valgus were 32.5, 9.2, 10.8, and 5.8 degree respectively. One patient had delayed postoperative wound healing. There was no leg length discrepancy observed in any patient and good osseointegration was observed on the interface between the bone and talus prosthesis in all subjects. CONCLUSION: The modular structure of the prosthesis developed in this study seems to be convenient for prosthesis implantation and screws distribution. And the combination of solid and porous structure improves the initial stability and promotes bone integration. Therefore, 3D printed custom-made modular talus prosthesis could be an alternative option for talus reconstruction in talus malignant tumor patients.


Subject(s)
Bone Neoplasms , Printing, Three-Dimensional , Prosthesis Design , Talus , Humans , Talus/surgery , Talus/diagnostic imaging , Male , Adult , Female , Bone Neoplasms/surgery , Bone Neoplasms/diagnostic imaging , Retrospective Studies , Middle Aged , Young Adult , Prosthesis Implantation/methods , Prosthesis Implantation/instrumentation , Adolescent , Ankle Joint/surgery , Ankle Joint/diagnostic imaging , Osseointegration , Treatment Outcome , Range of Motion, Articular , Prostheses and Implants
11.
Arch Orthop Trauma Surg ; 144(6): 2547-2552, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38777907

ABSTRACT

INTRODUCTION: Pathological destruction of the axis vertebra leads to a highly unstable condition in an upper cervical spine. As surgical resection and anatomical reconstruction of the second cervical vertebrae represents a life threatening procedure, less radical approaches are preferred and only few cases of C2 prosthesis are described in literature. CASE DESCRIPTION: The focus of this case report is a 21-year-old man with a pathological fracture of C2 managed primarily surgically with the C1-C3 dorsal fusion. Due to the progression of giant cell tumor and destruction of the axis vertebra, C2 prosthesis through anterior approach and dorsal occipito-cervical fusion C0-C4 were performed. Postoperative infection was managed surgically with a 2-staged dorsal debridement, ostheosynthesis material change and autologous bone graft. After a 4 week-intravenous therapy with the ceftriaxone in combination with the amoxicillin/clavulanate, followed by 12 week per oral therapy with amoxicillin/clavulanate in combination with ciprofloxacin, the complete recovery of the infection was achieved. Radiotherapy was initiated 2 months after the last revision surgery and the patient showed a good clinical outcome with stable construct at a 1 year follow-up. A review of literature of all reported C2 prosthesis cases was performed CONCLUSION: C2 prosthesis allows a more radical resection in pathological processes involving the axis vertebra. Combined with the posterior fusion, immediate stability is achieved. Anterior surgical approach is through a highly unsterile oral environment which presents a high-risk of postoperative infection.


Subject(s)
Spinal Fractures , Spinal Fusion , Humans , Male , Spinal Fusion/methods , Young Adult , Spinal Fractures/surgery , Cervical Vertebrae/surgery , Cervical Vertebrae/injuries , Axis, Cervical Vertebra/surgery , Axis, Cervical Vertebra/injuries , Fractures, Spontaneous/surgery , Fractures, Spontaneous/etiology , Prosthesis Implantation/methods , Spinal Neoplasms/surgery
12.
Article in English | MEDLINE | ID: mdl-38727533

ABSTRACT

Preoperative calculations showed that the 9-mm inlet, 6-mm outlet, 25-cc pump chambers and 65-73 bpm would be optimal for a 5-year-old patient suffering from restrictive cardiomyopathy, with a body surface area of 0.59 m2 (1.5 L/min flow for a cardiac index of 2.5). After re-sternotomy and standard bicaval cannulation for cardiopulmonary bypass, the procedure was performed under normothermic conditions and on the beating heart. Biventricular support was established with the Berlin Heart Excor using biatrial cannulation. For left atrial cannulation, induced ventricular fibrillation was used. The 9-mm inlet cannulas were inserted into the left and right atria, respectively. The 6-mm outlet cannulas were implanted using 8-mm interposition vascular grafts for the aorta and the main pulmonary artery, respectively. Cannulas were tunnelled through the epigastric space, with systems crossing outside of the body. The 25-cc chambers were used for both right ventricular assist device and left ventricular assist device support, which subsequently showed full emptying and filling.


Subject(s)
Cardiomyopathy, Restrictive , Heart-Assist Devices , Humans , Cardiomyopathy, Restrictive/surgery , Cardiomyopathy, Restrictive/diagnosis , Male , Child, Preschool , Heart Atria/surgery , Cardiac Catheterization/methods , Cardiac Catheterization/instrumentation , Heart Failure/surgery , Prosthesis Implantation/methods
13.
Otol Neurotol ; 45(5): 556-563, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38693091

ABSTRACT

OBJECTIVE: To investigate the feasibility of early sound processor loading with two separate bone-anchored hearing aid implants 1 to 2 weeks after implantation. Secondary endpoints included registration of any postoperative complications, skin reactions, and any adverse events. STUDY DESIGN: Prospective, nonrandomized, noncontrolled, multicenter clinical trial. SETTING: Tertiary referral center. PATIENTS: Sixty adult patients, eligible for bone-anchored hearing aid surgery, were enrolled. INTERVENTION: Implantation of the bone-anchored hearing aid implants were done using minimally invasive surgery with tissue preservation. MAIN OUTCOME MEASURE: Implant stability quotient (ISQ) values were recorded using resonance frequency analysis. Follow-ups were scheduled 5 to 12 days, 4 to 8 weeks, 6 months, and 12 months postoperatively. Differences between the lowest ISQ values (ISQ low) over time were analyzed by paired-samples t test with a significance level of 0.05. Skin and soft tissue reactions were assessed according to Holger's classification. RESULTS: Loading time of the Ponto Wide implant was 11.6 ± 1.4 days (SD) in average (median, 12 d; range, 7-19 d). Loading of the Ponto BHX implant was done 9.7 ± 3.5 days (SD) postoperatively (median, 9 d; range, 5-19 d). The implant stability increased significantly during the 12-month study period with both implants. One Ponto BHX implant was lost. Skin and soft tissue reactions were few in both groups. Across all planned follow-up visits, no skin and soft tissue reactions were observed in 86% (Ponto BHX implant) and 85% (Ponto Wide implant). CONCLUSION: Very early loading of sound processors after percutaneous bone-anchored hearing system surgery is safe already 1 to 2 weeks postoperatively.


Subject(s)
Hearing Aids , Humans , Male , Female , Middle Aged , Adult , Aged , Prospective Studies , Treatment Outcome , Suture Anchors , Bone-Anchored Prosthesis , Prosthesis Implantation/methods , Young Adult , Aged, 80 and over
14.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Article in Russian | MEDLINE | ID: mdl-38742501

ABSTRACT

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Subject(s)
Contact Lenses , Keratoconus , Sclera , Visual Acuity , Humans , Keratoconus/surgery , Keratoconus/diagnosis , Keratoconus/physiopathology , Keratoconus/therapy , Female , Male , Adult , Sclera/surgery , Prosthesis Implantation/methods , Prosthesis Implantation/instrumentation , Treatment Outcome , Corneal Topography , Prostheses and Implants , Young Adult , Prosthesis Fitting/methods , Adolescent , Corneal Stroma/surgery
15.
Am J Otolaryngol ; 45(4): 104328, 2024.
Article in English | MEDLINE | ID: mdl-38733715

ABSTRACT

PURPOSE: To evaluate outcomes following explantation of percutaneous or transcutaneous bone conduction implants (pBCIs or tBCIs) and subsequent implantation of transcutaneous active bone conduction hearing devices (BCHDs); to provide guidance regarding staging of surgery and adjunctive procedures. MATERIALS AND METHODS: Retrospective chart review of eight adult subjects (ten ears) with pBCIs or tBCIs who underwent explantation of their device and subsequent implantation with a BCHD [MED-EL BONEBRIDGE™ (n = 7, 70 %) or Cochlear™ Osia® (n = 3, 30 %)]. RESULTS: Reasons for pBCI or tBCI explantation were pain (60 %, 6/10), infection (60 %, 6/10), skin overgrowth (50 %, 5/10), and inability to obtain new processors (20 %, 2/10). Median time between pBCI or tBCI removal and BCHD staged implant was 4.7 (IQR 2.2-8.1) months. Two subjects developed complications following BCHD implantation. One had a persistent wound overlying the osseointegrated screw after removal of the pBCI abutment, requiring removal and temporalis rotational flap. Staged Osia® implantation was performed, but ultimately wound dehiscence developed over the device. The second subject experienced an infection after BONEBRIDGE™ implantation (32 days after pBCI explant), necessitating washout and treatment with intravenous antibiotics. There was subsequent device failure. CONCLUSION: The transition from a pBCI or tBCI to a novel transcutaneous device is nuanced. Staged pBCI or tBCI explantation and novel BCHD implantation with sufficient time for wound healing is vital. Adjunctive procedures to augment soft tissue in cases of prior attenuation may be required to avoid complications with larger internal devices.


Subject(s)
Bone Conduction , Device Removal , Hearing Aids , Humans , Hearing Aids/adverse effects , Retrospective Studies , Male , Female , Middle Aged , Adult , Treatment Outcome , Aged , Bone-Anchored Prosthesis , Prosthesis Implantation/methods , Prosthesis Implantation/adverse effects , Hearing Loss, Conductive/surgery , Hearing Loss, Conductive/etiology
16.
Herzschrittmacherther Elektrophysiol ; 35(2): 155-164, 2024 Jun.
Article in German | MEDLINE | ID: mdl-38748284

ABSTRACT

The implantation of electrodes for cardiac implantable electronic devices (CIED) requires profound technical understanding and precise execution. The positioning of electrodes in the right ventricle and atrium has significant implications for patient safety and the effectiveness of CIED therapy. Particular focus is given to the distinction between apical and septal stimulation in ventricular positioning. Based on current data, this article provides a practice-oriented guide that leads implanters through the individual steps of electrode positioning. The implantation of electrodes for physiological stimulation (cardiac resynchronization therapy, CRT, and conduction system pacing, CSP) is not addressed in this article.


Subject(s)
Cardiac Surgical Procedures , Electrodes, Implanted , Humans , Evidence-Based Medicine , Prosthesis Implantation/methods , Cardiac Surgical Procedures/instrumentation , Cardiac Surgical Procedures/methods
17.
Int J Cardiol ; 407: 132113, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38697398

ABSTRACT

BACKGROUND: Axillary vein puncture (AVP) is a valid alternative to Subclavan vein puncture for leads insertion in cardiac implantable electronic device implantation, that may reduce acute and delayed complications. Very few data are available about ICD recipients. A simplified AVP technique is described. METHODS: All the patients who consecutively underwent "de novo" ICD implantation, from March 2006 to December 2020 at the University of Verona, were considered. Leads insertion was routinely performed through an AVP, according to a simplified technique. Outcome and complications have been retrospectively analyzed. RESULTS: The study population consisted of 1711 consecutive patients. Out of 1711 patients, 38 (2.2%) were excluded because they were implanted with Medtronic Sprint Fidelis lead. Out of 1673 ICD implantations, 963 (57.6%) were ICD plus cardiac resynchronization therapy, 434 (25.9%) were dual-chamber defibrillators, and 276 (16.5%) were single-chamber defibrillators, for a total of 3879 implanted leads. The AVP success rate was 99.4%. Acute complications occurred in 7/1673 (0.42%) patients. Lead failure (LF) occurred in 20/1673 (1.19%) patients. Comparing the group of patients with lead failure with the group without LF, the presence of three leads inside the vein was significantly associated with LF, and the multivariate analysis confirmed three leads in place as an independent predictor of LF. CONCLUSION: AVP, according to our simplified technique, is safe, effective, has a high success rate, and a very low complication rate. The incidence of LF was exceptionally low. The advantages of AVP are maintained over time in a population of ICD recipients.


Subject(s)
Axillary Vein , Defibrillators, Implantable , Punctures , Humans , Defibrillators, Implantable/adverse effects , Male , Female , Retrospective Studies , Aged , Middle Aged , Axillary Vein/diagnostic imaging , Prosthesis Implantation/methods , Prosthesis Implantation/adverse effects , Prosthesis Implantation/instrumentation , Treatment Outcome , Time Factors
18.
Otolaryngol Pol ; 78(3): 1-5, 2024 Jun 30.
Article in English | MEDLINE | ID: mdl-38808636

ABSTRACT

<b><br>Introduction:</b> In an era of wide accessibility to various systems for hearing impairment prosthetics, there exists a broad spectrum of surgical techniques facilitating system implantation.</br> <b><br>Aim:</b> The aim of the study is to present the technique of vertical incision in the implantation of the Baha Attract magnetic system as an alternative incision, maintaining a compromise between optimizing the surgical procedure and preserving the functionality and quality of life of the patient.</br> <b><br>Materials and methods:</b> The vertical incision technique is presented based on 5 patients treated between December 2022 and March 2023 diagnosed with conductive or mixed hearing loss.</br> <b><br>Results:</b> There were no adverse consequences or complications resulting from the performed surgical incision. All patients experienced uncomplicated healing. Patients are using sound processor magnets ranging from 4-5 in strength and Baha<sup></sup> 6 Max sound processors weighing 11.5 g.</br> <b><br>Conclusions:</b> The vertical incision technique serves as an alternative to the C-shaped perimeter incision, allowing for the optimization and standardization of the surgical procedure, resulting in a smooth scar formation and maintaining good audiological and aesthetic outcomes.</br>.


Subject(s)
Hearing Aids , Humans , Female , Male , Adult , Hearing Loss, Conductive/surgery , Middle Aged , Prosthesis Implantation/methods , Treatment Outcome
19.
Arq Bras Oftalmol ; 87(6): e2021, 2024.
Article in English | MEDLINE | ID: mdl-38597522

ABSTRACT

Implantation of glaucoma drainage devices is a valuable therapeutic option, particularly in children with glaucoma refractory to primary surgical treatment. Glaucoma drainage devices are typically used when conjunctival scarring hampers filtration surgery or prior angle procedures are not effective in controlling intraocular pressure. Despite known complications, the use of glaucoma drainage devices in children has increased in recent years, even as the primary surgical option. In this review, we evaluate the results of recent studies involving the implantation of glaucoma drainage devices in children, discussing new advances, and comparing the success rates and complications of different devices.


Subject(s)
Conjunctival Diseases , Glaucoma Drainage Implants , Glaucoma , Child , Humans , Glaucoma Drainage Implants/adverse effects , Glaucoma/surgery , Intraocular Pressure , Prosthesis Implantation/methods , Retrospective Studies , Treatment Outcome
20.
Arch Ital Urol Androl ; 96(1): 12214, 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38572722

ABSTRACT

INTRODUCTION AND OBJECTIVES: Artificial urinary sphincter (AUS) is a treatment option for women with stress urinary incontinence (SUI) after failure of previous surgery or as a primary procedure in severe intrinsic sphincter deficiency (ISD). The aim of the study was to assess the long-term efficacy and risk factors for surgical revision and definitive explantation of AUS laparoscopic implantation in female patients. METHODS: A retrospective review of all women submitted to AUS implantation between April 2005 and March 2023 was conducted. The AUS was implanted via transperitoneal laparoscopic approach, by two experienced surgeons. The primary endpoint was postoperative continence. Continence was defined as no leakage and no pad usage or leakage and/or pad usage with no impact on social life and failure as leakage and/or pad usage impacting social life. As secondary outcomes, clinical predictive factors for AUS revision and definitive explantation were evaluated. RESULTS: In the last 18 years, females with a mean age of 68±12 years-old were submitted to laparoscopic implantation of AUS. Early overall complication rate was 16%, but only one case was Clavien-Dindo ≥3. After a median follow-up of 67 months, 22.2% of the patients needed a device revision, the majority due to mechanical device dysfunction. AUS definitive explantation was performed in 16%, mainly due to urethral/vaginal erosion (9.9%) and infection (6.2%). Patients with age ≥70 years and follow-up ≥10 years significantly predisposed for device revision. At the time of the last follow-up, 72% of the patients were keeping the urinary continency. CONCLUSIONS: Laparoscopic AUS implantation in females is an effective treatment for SUI due to ISD. Meanwhile, adequate patient selection, multidisciplinary evaluation and careful expectation management are essential to achieving good results, concerning their significant complication rate.


Subject(s)
Laparoscopy , Urethral Diseases , Urinary Incontinence, Stress , Urinary Sphincter, Artificial , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Urinary Sphincter, Artificial/adverse effects , Treatment Outcome , Urinary Incontinence, Stress/surgery , Urinary Incontinence, Stress/etiology , Laparoscopy/adverse effects , Urethra/surgery , Urethral Diseases/surgery , Prosthesis Implantation/methods , Retrospective Studies