Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.452
Filter
1.
In Vivo ; 38(4): 2085-2089, 2024.
Article in English | MEDLINE | ID: mdl-38936940

ABSTRACT

BACKGROUND: Robot-assisted partial nephrectomy (RAPN) has become the standard treatment for small renal tumors, including highly complex cases. However, applying RAPN to renal tumors in the horseshoe kidney (HSK) is clinically challenging due to malformations and complex blood supply. Herein, we present two cases of RAPN in patients with HSK treated using selective artery clamping methods. CASE REPORTS: A 61-year-old male with a 15 mm renal tumor located on the upper pole of the right HSK was referred to our Department. The patient underwent RAPN via the transperitoneal approach, following a three-dimensional computed tomography (3D-CT) assessment. Additionally, before surgery, we confirmed which renal arteries would be clamped in surgery by examining the kidney regions supplied by each renal artery. The second patient referred to our Department, a 45-year-old male, had a 46 mm renal tumor located on the isthmus of the HSK. His tumor received blood supply from two renal arteries, with the bilateral collecting systems converging and forming a ureter on 3D-CT. The patient underwent RAPN through an intraperitoneal approach in the semi-lateral position, with port placement lower than in standard RAPN. Pathological examinations revealed clear-cell renal cell carcinoma with negative surgical margins in both cases. Both patients had no recurrences or metastases at 53 and 13 months post-surgery, respectively. CONCLUSION: We present cases successfully treated with RAPN with selective artery clamping methods for HSK using 3D-CT without encountering complications, even in isthmus tumors.


Subject(s)
Carcinoma, Renal Cell , Fused Kidney , Kidney Neoplasms , Nephrectomy , Robotic Surgical Procedures , Humans , Male , Nephrectomy/methods , Middle Aged , Carcinoma, Renal Cell/surgery , Carcinoma, Renal Cell/diagnostic imaging , Carcinoma, Renal Cell/pathology , Robotic Surgical Procedures/methods , Kidney Neoplasms/surgery , Kidney Neoplasms/diagnostic imaging , Kidney Neoplasms/pathology , Fused Kidney/surgery , Fused Kidney/diagnostic imaging , Renal Artery/surgery , Renal Artery/diagnostic imaging , Renal Artery/abnormalities , Tomography, X-Ray Computed , Treatment Outcome , Constriction
2.
Lasers Med Sci ; 39(1): 161, 2024 Jun 22.
Article in English | MEDLINE | ID: mdl-38907065

ABSTRACT

Electrosurgical and ultrasonic devices are used in surgical procedures for hemostatic sealing and bisection of vascular tissues. Previous benchtop studies alternatively demonstrated successful infrared laser sealing and cutting of blood vessels, in a sequential, two-step approach. This study describes a smaller, laparoscopic device compatible design, and simultaneous approach to sealing and bisection of vessels, with potential optical feedback. A 1470-nm infrared diode laser sealed and bisected 40 porcine renal arteries, ex vivo. A reciprocating, side-firing, optical fiber, housed in a transparent square quartz optical chamber (2.7 × 2.7 × 25 mm outer dimensions), delivered laser energy over an 11 mm scan length, with a range of incident powers (41-59 W) and treatment times (5-21 s). Vessel diameters ranged from 2.5 to 4.8 mm. Vessel burst pressure measurements were performed on each cut end (n = 80) with success indicated by pressures exceeding 360 mmHg. All vessel ends were successfully sealed and bisected (80/80). The highest incident power, 59 W, yielded short treatment times of 5-6 s. Peak temperatures on the external chamber surface reached 103 oC. Time to cool down to body temperature measured 37 s. Infrared lasers simultaneously seal and bisect blood vessels, with treatment times comparable to, and temperatures and cooling times lower than reported for conventional devices. Future work will focus on integrating the fiber and chamber into a standard 5-mm-outer-diameter laparoscopic device. Customization of fiber scan length to match vessel size may also reduce laser energy deposition, enabling lower peak temperatures, treatment times, and cooling times.


Subject(s)
Lasers, Semiconductor , Renal Artery , Animals , Lasers, Semiconductor/therapeutic use , Swine , Renal Artery/surgery , Infrared Rays , Hemostasis, Surgical/instrumentation , Hemostasis, Surgical/methods , Laser Therapy/instrumentation , Laser Therapy/methods , Laparoscopy/methods , Laparoscopy/instrumentation
3.
J Robot Surg ; 18(1): 241, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38833079

ABSTRACT

While partial nephrectomy offers oncologic efficacy and preserves renal function for T1 renal tumors, renal artery pseudoaneurysm (RAP) remains a rare but potentially life-threatening complication. This study compared RAP incidence across robotic-assisted (RAPN), laparoscopic (LPN), and open (OPN) partial nephrectomies in a large tertiary oncological center. This retrospective study analyzed 785 patients undergoing partial nephrectomy between 2012 and 2022 (398 RAPN, 122 LPN, 265 OPN). Data included demographics, tumor size/location, surgical type, clinical presentation, treatment, and post-operative outcomes. The primary outcome was RAP incidence, with secondary outcomes including presentation, treatment efficacy, and renal function. Seventeen patients (2.1%) developed RAP, presenting with massive hematuria (100%), hemorrhagic shock (5.8%), and clot retention (23%). The median onset was 12 days postoperatively. RAP occurred in 4 (1%), 4 (3.3%), and 9 (3.4%) patients following RAPN, LPN, and OPN, respectively (p = 0.04). Only operative length and surgical approach were independently associated with RAP. Selective embolization achieved immediate bleeding control in 94%, with one patient requiring a second embolization. No additional surgery or nephrectomy was needed. Estimated GFR at one year was similar across both groups (p = 0.53). RAPN demonstrated a significantly lower RAP incidence compared to LPN and OPN (p = 0.04). Emergency angiographic embolization proved effective, with no long-term renal function impact. This retrospective study lacked randomization and long-term follow-up. Further research with larger datasets and longer follow-ups is warranted. This study suggests that robotic-assisted partial nephrectomy is associated with a significantly lower risk of RAP compared to traditional approaches. Emergency embolization effectively treats RAP without compromising long-term renal function.


Subject(s)
Aneurysm, False , Kidney Neoplasms , Laparoscopy , Nephrectomy , Postoperative Complications , Renal Artery , Robotic Surgical Procedures , Humans , Nephrectomy/methods , Nephrectomy/adverse effects , Aneurysm, False/surgery , Robotic Surgical Procedures/methods , Robotic Surgical Procedures/adverse effects , Male , Female , Middle Aged , Laparoscopy/methods , Laparoscopy/statistics & numerical data , Retrospective Studies , Postoperative Complications/epidemiology , Postoperative Complications/prevention & control , Postoperative Complications/etiology , Aged , Renal Artery/surgery , Kidney Neoplasms/surgery , Incidence , Treatment Outcome , Embolization, Therapeutic/methods
4.
BMC Nephrol ; 25(1): 135, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38622526

ABSTRACT

BACKGROUND: Renal artery variations are clinically significant due to their implications for surgical procedures and renal function. However, data on these variations in Sudanese populations are limited. This study aimed to determine the prevalence and characteristics of renal artery variations in a Sudanese population. METHODS: A cross-sectional retrospective study was conducted in Khartoum state from October 2017 to October 2020. A total of 400 Sudanese participants who underwent abdominal CT scans were included. Data on demographic characteristics, kidney measurements, and renal vasculature were collected and analyzed using descriptive statistics and inferential tests. RESULTS: The mean age of participants was 46.7 ± 18 years, with a nearly equal gender distribution. Overall, renal artery variations were present in 11% of participants, with accessory renal arteries observed in 6% of the study population. Among those with accessory vessels, 50% were on the right side, 29.2% on the left, and 20.8% bilateral, distributed across hilar 29.2%, lower polar 29.2%, and upper polar 41.7% regions. No significant associations were found between accessory renal arteries and age or gender (p-value > 0.05). However, participants with accessory renal arteries exhibited significantly narrower width 5.0 ± 1.4 than those with no with accessory renal arteries 5.8 ± 1.1 (p-value 0.002) Early dividing renal arteries were found in 5% of participants, with nearly half being bilateral. No significant associations were found between the presence of early dividing renal arteries and demographic or renal measurements (p-value > 0.05). CONCLUSION: This study provides valuable insights into the prevalence and characteristics of renal artery variations in a Sudanese population. The findings contribute to our understanding of renal anatomy in this demographic and can inform clinical practice and surgical planning, particularly in renal transplantation and other renal procedures.


Subject(s)
Renal Artery , Vascular Diseases , Humans , Adult , Middle Aged , Renal Artery/diagnostic imaging , Renal Artery/surgery , Prevalence , Retrospective Studies , Kidney/blood supply , Tomography, X-Ray Computed
5.
J Cardiovasc Surg (Torino) ; 65(2): 119-123, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38618696

ABSTRACT

This article summarizes the key findings in literature up to date on the endovascular treatment of complex abdominal aortic aneurysms (AAAs) employing the chimney technique. Additionally, an unexplored pitfall is described regarding the target vessel angulation. Although balloon-expandable covered stents present more favorable configuration in downward-oriented target vessels, transverse and upward-oriented target vessels may benefit from other endovascular techniques imploring careful case planning and further investigation on the topic.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Renal Artery , Stents , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Humans , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Renal Artery/surgery , Renal Artery/diagnostic imaging , Treatment Outcome , Endovascular Procedures/instrumentation , Prosthesis Design , Risk Factors
6.
BMJ Case Rep ; 17(4)2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38663899

ABSTRACT

Renal artery stenosis can complicate the management of heart failure with reduced ejection fraction, as it is a conventional contraindication to the use of ACE inhibitors. We report a case in which bilateral renal artery revascularisation allowed the safe reintroduction of enalapril (and subsequently sacubitril valsartan) in a patient with severe left ventricular systolic dysfunction. There is a role for renal artery angioplasty in selected patients to allow optimal medical therapy for patients with heart failure due to impaired systolic function.


Subject(s)
Enalapril , Heart Failure , Renal Artery Obstruction , Renal Artery , Valsartan , Humans , Renal Artery Obstruction/surgery , Renal Artery Obstruction/complications , Renal Artery Obstruction/therapy , Renal Artery/surgery , Valsartan/therapeutic use , Enalapril/therapeutic use , Male , Tetrazoles/therapeutic use , Drug Combinations , Aminobutyrates/therapeutic use , Ventricular Dysfunction, Left , Biphenyl Compounds , Aged , Angiotensin Receptor Antagonists/therapeutic use
7.
World J Urol ; 42(1): 161, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38488940

ABSTRACT

PURPOSE: Accurate surgical reconstruction of arterial vascular supply is a crucial part of living kidney transplantation (LDKT). The presence of multiple renal arteries (MRA) in grafts can be challenging. In the present study, we investigated the impact of ligation versus anastomosis of small accessory graft arteries on the perioperative outcome. METHODS: Clinical and radiological outcomes of 51 patients with MRA out of a total of 308 patients who underwent LDKT with MRA between 2011 and 2020 were stratified in two groups and analyzed. In group 1 (20 patients), ligation of accessory arteries (ARAs) and group 2 (31 patients) anastomosis of ARAs was performed. RESULTS: Significant differences were observed in the anastomosis-, surgery-, and warm ischemia time (WIT) in favor of group 1. Students t-test showed comparable serum creatinine levels of 2.33 (± 1.75) to 1.68 (± 0.83) mg/dL in group 1 and 2.63 (± 2.47) to 1.50 (± 0.41) mg/dL in group 2, were seen from 1 week to 1 year after transplant. No increased rates of Delayed graft function (DGF), primary transplant dysfunction and transplant rejection were seen, but graft loss and revision rates were slightly higher when the ARAs were ligated. Analysis of Doppler sonography revealed that segmental perfusion deficits tend to regenerate during the clinical course. CONCLUSION: Ligation of smaller accessory renal arteries may not affect the outcome of living kidney transplantation, except for a minor increase in the reoperation rate. Segmental perfusion deficits of the graft seem to regenerate in most cases as seen in Doppler sonography.


Subject(s)
Kidney Transplantation , Humans , Kidney Transplantation/adverse effects , Renal Artery/surgery , Living Donors , Retrospective Studies , Graft Survival , Kidney/diagnostic imaging , Kidney/surgery , Kidney/blood supply , Treatment Outcome
8.
Vasc Endovascular Surg ; 58(6): 683-684, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38509023
9.
BMJ Case Rep ; 17(3)2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38538096

ABSTRACT

Transplant renal artery stenosis (TRAS) represents a significant vascular complication subsequent to renal transplantation. This pathology is associated with grave implications including graft dysfunction and mortality. Early identification and therapeutical intervention are imperative for preserving graft longevity and achieving optimal clinical outcomes. We detail the case of a male in his 20s, following renal transplantation, who encountered recurrent TRAS, aetiologically linked to mechanical arterial kinking. Initial management using endovascular techniques yielded insufficient resolution. Consequently, the persistence of endovascular-resistant stenosis necessitated a surgical bypass intervention using the great saphenous vein, granting a 2-year period devoid of restenosis. The existing literature emphasises the indispensability of discerning the appropriate juncture for transitioning from endovascular to surgical management in TRAS cases. The robustness and durability of bypass grafts present an efficacious therapeutical strategy in contemporaneous practice.


Subject(s)
Endovascular Procedures , Kidney Transplantation , Renal Artery Obstruction , Humans , Male , Endovascular Procedures/adverse effects , Kidney Transplantation/adverse effects , Renal Artery/diagnostic imaging , Renal Artery/surgery , Renal Artery Obstruction/diagnostic imaging , Renal Artery Obstruction/etiology , Renal Artery Obstruction/surgery , Retrospective Studies , Saphenous Vein , Treatment Outcome , Young Adult , Adult
11.
Transplant Proc ; 56(1): 257-259, 2024.
Article in English | MEDLINE | ID: mdl-38195286

ABSTRACT

Renal artery aneurysms (RAAs) may occur in patients with transplanted kidneys, either through de novo development or as a preexisting feature of the donor kidney. How this vascular condition progresses in patients on immunosuppressive therapy after transplantation is poorly understood, and to our knowledge, consensus guidelines for treating transplant patients with RAA have not been developed. We present the case of a kidney allograft recipient on triple immunosuppressive therapy in whom postoperative imaging revealed a 13-mm renal artery aneurysm in the renal hilum not amenable to endovascular intervention. We review systemic influences on aneurysm formation and how matrix metalloproteinases may interact with immunosuppressive medications. Surveillance imaging over 5 years has shown a stable aneurysm, and the patient has maintained stable renal function with adequate creatinine levels and no adverse symptoms.


Subject(s)
Aneurysm , Kidney Diseases , Kidney Transplantation , Humans , Renal Artery/diagnostic imaging , Renal Artery/surgery , Kidney , Aneurysm/diagnostic imaging , Aneurysm/etiology , Aneurysm/surgery , Kidney Transplantation/adverse effects , Treatment Outcome
12.
Vasc Med ; 29(1): 50-57, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38084723

ABSTRACT

INTRODUCTION: Although renal stenting is the standard revascularization method for atherosclerotic renal artery stenosis (RAS) (FMD-RAS), stenting in fibromuscular dysplasia (FMD) RAS is usually limited to periprocedural complications of angioplasty and primary arterial dissection. The main aim of the study was to retrospectively analyze the immediate and long-term results of renal stenting versus angioplasty in patients with FMD. METHODS: Of 343 patients in the ARCADIA-POL registry, 58 patients underwent percutaneous treatment due to FMD-RAS (in 70 arteries). Percutaneous transluminal renal angioplasty (PTRA) was performed as an initial treatment in 61 arteries (PTRA-group), whereas primary stenting was undertaken in nine arteries (stent-group). Stent-related complications were defined as: in-stent restenosis > 50% (ISR); stent fracture; under-expansion; or migration. RESULTS: In the PTRA-group, the initial restenosis rate was 50.8%. A second procedure was then performed in 22 arteries: re-PTRA (12 arteries) or stenting (10 arteries). The incidence of recurrent restenosis after re-PTRA was 41.7%. Complications occurred in seven of 10 (70%) arteries secondarily treated by stenting: two with under-expansion and five with ISR. In the stent-group, stent under-expansion occurred in one case (11.1%) and ISR in three of nine stents (33.3%). In combined analysis of stented arteries, either primarily or secondarily, stent-related complications occurred in 11/19 stenting procedures (57.9%): three due to under-expansion and eight due to ISRs. Finally, despite several revascularization attempts, four of 19 (21%) stented arteries were totally occluded and one was significantly stenosed at follow-up imaging. CONCLUSION: Our study indicates that renal stenting in FMD-RAS may carry a high risk of late complications, including stent occlusion. Further observational data from large-scale registries are required.


Subject(s)
Angioplasty, Balloon , Fibromuscular Dysplasia , Renal Artery Obstruction , Humans , Renal Artery/diagnostic imaging , Renal Artery/surgery , Fibromuscular Dysplasia/complications , Fibromuscular Dysplasia/diagnostic imaging , Fibromuscular Dysplasia/therapy , Angioplasty, Balloon/adverse effects , Retrospective Studies , Treatment Outcome , Renal Artery Obstruction/diagnostic imaging , Renal Artery Obstruction/etiology , Renal Artery Obstruction/therapy , Risk Assessment , Stents/adverse effects
13.
Vasc Endovascular Surg ; 58(4): 399-404, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37962531

ABSTRACT

The double-barrel stenting (DBS) is a technique in which 2 parallel stents are simultaneously deployed through the same reinforced fenestration, into 2 adjacent target vessels. Prior reports describe the application of this technique for the treatment of superior mesenteric artery dissection with aneurysmal degeneration, coronary artery bifurcations, aortic arch branches, and intracranial aneurysms. The DBS technique is particularly useful in the context of fenestrated repair (FEVAR) of complex anatomy aortic aneurysms when the origin of visceral arteries branch off the aorta very close to each other or present early branches. We herein describe a case series including 7 patients who underwent a FEVAR procedure for thoracoabdominal and juxtarenal aortic aneurysms in which the presence of accessory renal arteries (ARA) or early renal branches was the reason for the application of this technique. Technical success was 100% and all stents were patent in the last follow-up CT scan (follow-up range: 1.8-62.8 months). There was only 1 small endoleak from indetermined source potentially related to the DBS, but the aneurysm sac decreased in size during follow-up and no secondary intervention was needed. Therefore, the DBS technique is a viable option for the incorporation of ARA or early renal branches to a fenestrated repair of aortic aneurysms with complex anatomy.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Aneurysm, Thoracic , Aortic Aneurysm , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Renal Artery/diagnostic imaging , Renal Artery/surgery , Endovascular Aneurysm Repair , Treatment Outcome , Risk Factors , Stents , Aortic Aneurysm, Abdominal/surgery , Endovascular Procedures/adverse effects , Prosthesis Design , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery
14.
Am Surg ; 90(4): 748-753, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37885074

ABSTRACT

BACKGROUND: Renal artery aneurysm (RAA) is a rare condition that involves dilation of all layers of the arterial wall of the renal artery. The risk of rupture is rare, but intervention is recommended for larger aneurysms. Surgical decision-making regarding live donor renal transplantation (LDRT) centers around safety for the living donor, and laterality of the donated kidney is based on providing the donor with the best longevity pertaining to the remaining kidney. We looked to review our long-term outcomes surrounding live donor transplants from donors with RAA with ex vivo resection and reconstruction prior to implantation. METHODS: A retrospective review was done of all laparoscopic live donor transplant nephrectomies with ex vivo aneurysm resection, reconstruction, and implantation at a single center. RESULTS: Three pairs of patients underwent successful laparoscopic donor nephrectomy, RAA resection, reconstruction, and transplantation of kidney. 2 males and 1 female ages 47 to 58 years of age underwent transplantation. The donors at 5 years of follow-up were noted to be functioning appropriately with no long-term sequelae of their donation and a mean remanent kidney function of 63 mL/min. DISCUSSION: For potential live donors with asymptomatic, unilateral renal artery aneurysm and no systemic disease, live donation with ex vivo resection and reconstruction can be performed with excellent long-term donor and recipient outcomes.


Subject(s)
Aneurysm , Renal Artery , Male , Humans , Female , Renal Artery/surgery , Kidney , Aneurysm/surgery , Living Donors , Patients
15.
Vasc Endovascular Surg ; 58(3): 308-315, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37919942

ABSTRACT

OBJECTIVE: The optimal management strategy for patients with accessory renal arteries undergoing endovascular aortic repair is unclear. This study aimed to investigate the impact of accessory renal artery (aRA) embolization on postoperative renal deterioration and to identify the predictors of postoperative renal deterioration in patients who underwent endovascular aortic repair (EVAR). METHODS: A retrospective single-centre observational study was conducted at our hospital. Of 331 consecutive patients who underwent endovascular aortic repair between April 2011 and February 2021, 29 patients with an aRA were included in this study. Spearman's rank correlation coefficients of decrease in estimated glomerular filtration rate (eGFR), renal volume reduction rate, infarcted renal volume, and quantity of contrast use for postoperative renal deterioration were analyzed. The correlation coefficients of the correlations between infarcted renal volume, renal volume reduction rate, and decrease in eGFR and the rate of aRA diameter were also analyzed. Multivariable nominal logistic regression analyses were conducted to evaluate the odds of postoperative renal deterioration. RESULTS: The renal volume reduction rate and infarcted renal volume had a significant positive correlation with the decrease in eGFR. Body surface area and preoperative renal volume were significantly but negatively correlated with the decrease in eGFR. The infarcted renal volume, renal volume reduction rate, and decrease in eGFR were significantly and positively correlated with the aRA diameter. The odds ratio for decreased eGFR rate in preoperative renal volume was .96 (95% CI 0.930‒.996, P = .009). CONCLUSIONS: EVAR with aRA embolization impacts postoperative renal deterioration in patients with preoperative low renal volume, and the diameter of the embolized aRA might be a predictor of postoperative renal deterioration.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Kidney Diseases , Humans , Endovascular Aneurysm Repair , Renal Artery/diagnostic imaging , Renal Artery/surgery , Retrospective Studies , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Treatment Outcome , Endovascular Procedures/adverse effects , Risk Factors
16.
Eur J Vasc Endovasc Surg ; 67(3): 417-425, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37926150

ABSTRACT

OBJECTIVE: To investigate outcomes of a novel, off the shelf multibranched endovascular stent graft for the treatment of thoraco-abdominal aortic aneurysm (TAAA) and pararenal abdominal aortic aneurysm (PAAA). METHODS: A prospective, single centre study including 15 patients (mean age, 63.4 ± 10.7 years; 13 male) with TAAA or PAAA treated from October 2019 to March 2021 with a G-Branch endograft (Lifetech Scientific, Shenzhen, China) featuring a mixed multibranch design with two inner and two outer branches for reconstruction of the visceral and bilateral renal arteries, respectively. Follow up assessments were scheduled before discharge and at 30 days, six and 12 months after the index procedure. Annual telephone interviews were performed beyond the initial 12 months. The Kaplan-Meier method was used to estimate cumulative mortality and morbidity rates after endovascular repair. RESULTS: Technical success was achieved in all 15 patients. Nine patients (60%) had TAAA and six (40%) had PAAA (mean maximum aneurysm diameter, 73.7 ± 15.8 mm). The median follow up was 31.4 months (range, 10.1 - 44.0 months). At 30 days, there was no death and 7% morbidity (one case of temporary spinal cord ischaemia on Day 4). At one year, the mortality rate was 7% (one death from stroke at 10 months) and morbidity was 13% (one other case of renal function decline at six months). There were no aneurysm dilatations, re-interventions, or access related complications, and two (13%) persistent type II endoleaks. The one year primary branch patency rate was 100% for the four renovisceral arteries in all 13 patients who underwent computed tomography examinations. One patient died of hepatocellular carcinoma 29 months post-operatively, resulting in an estimated three year mortality rate of 13%. CONCLUSION: The G-Branch endograft yielded high technical success with good early and midterm outcomes for the treatment of TAAA and PAAA. A large multicentre study is warranted.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Male , Middle Aged , Aged , Blood Vessel Prosthesis/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Aneurysm, Thoracic/surgery , Prospective Studies , Treatment Outcome , Postoperative Complications/etiology , Time Factors , Stents/adverse effects , Aortic Aneurysm, Abdominal/surgery , Renal Artery/surgery , Endovascular Procedures/adverse effects , Prosthesis Design
17.
Cardiovasc Intervent Radiol ; 47(1): 26-35, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38030849

ABSTRACT

BACKGROUND: Endovascular treatment of visceral and renal artery aneurysms and pseudoaneurysms is an effective, minimally invasive treatment that has been successfully used since the early 1990s, with refined and expanded techniques and tools currently offering excellent outcomes. Due to increased detection of such lesions in recent years, many of which are asymptomatic, revision of the indications for intervention and the correct endovascular treatment approaches has become essential. PURPOSE: This document will presume that the indication for treatment is clear and approved by the multidisciplinary team and will define the standards required for the performance of each intervention, as well as their relative advantages and limitations. CIRSE Standards of Practice documents are not intended to impose a standard of clinical patient care, but recommend a reasonable approach to, and best practices for, the performance of the endovascular treatment of visceral and renal artery aneurysms and pseudoaneurysms. METHODS: The writing group was established by the CIRSE Standards of Practice Committee and consisted of five clinicians with internationally recognised expertise in endovascular treatments. The writing group reviewed the existing literature on visceral and renal artery aneurysms and pseudoaneurysms, performing an evidence search using PubMed to identify publications in English and relating to human subjects from 1990 to 2022. The final recommendations were formulated through consensus. RESULTS: Endovascular treatment has an established role in the successful management of visceral and renal artery aneurysms and pseudoaneurysms, and this Standards of Practice document provides up-to-date recommendations for its safe performance.


Subject(s)
Aneurysm, False , Aneurysm , Embolization, Therapeutic , Endovascular Procedures , Humans , Aneurysm, False/diagnostic imaging , Aneurysm, False/surgery , Renal Artery/diagnostic imaging , Renal Artery/surgery , Endovascular Procedures/methods , Embolization, Therapeutic/methods , Aneurysm/diagnostic imaging , Aneurysm/surgery , Treatment Outcome
18.
Ann Vasc Surg ; 98: 102-107, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37423328

ABSTRACT

BACKGROUND: Complex open abdominal aortic aneurysm (AAA) repair often necessitates revascularization of renal arteries by either renal artery reimplantation or bypass. This study aims to evaluate the perioperative and short term outcomes between these 2 strategies of renal artery revascularization. METHODS: We performed a retrospective review of patients who underwent open AAA repair from 2004 to 2020 at our own institution. Patients who underwent elective suprarenal, juxtarenal, or type 4 thoracoabdominal aneurysm repair were identified using current procedural terminology (CPT) codes and a retrospectively maintained database of AAA patients. Patients who had symptomatic aneurysm or significant renal artery stenosis before AAA repair were excluded. Patient demographics, intraoperative conditions, renal function, bypass patency, and perioperative and postoperative outcomes at 30 days and 1 year were compared. RESULTS: One hundred and forty-three patients underwent either renal artery reimplantation (n = 86) or bypass (n = 57) during this time period. The mean age was 69.7 years and 76.2% of the patients were male. Median preoperative creatinine was 1.2 mg/dL for the renal bypass group versus 1.06 mg/dL for reimplantation (P = 0.088). Both groups had similar median preoperative glomerular filtration rate (GFR) of >60 mL/min (P = 0.13). Bypass and reimplantation groups had similar perioperative complications including acute kidney injury (51.8% vs. 49.4% P = 0.78), inpatient dialysis (3.6% vs. 1.2% P = 0.56), myocardial infarction (1.8% vs. 2.4% P = 0.99), and death (3.5% vs. 4.7% P = 0.99), respectively. During the 30-day follow-up period, renal artery stenosis was identified in 9.8% of bypasses and 6.7% of reimplantations (P = 0.71). Six point one percent of patients in the bypass group had renal failure requiring dialysis (both acute and permanent) compared to 1.3% in reimplantation group (P = 0.3). For those who had 1-year follow-up, the reimplantation group had higher new incidence of renal artery stenosis compared to bypass group (6 vs. 0 P = 0.16). CONCLUSIONS: Given that there is no significant difference in outcomes between renal artery reimplantation and bypass within 30 days or at 1-year follow-up, both bypass and reimplantation are acceptable means for renal artery revascularization during elective AAA repair.


Subject(s)
Acute Kidney Injury , Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Renal Artery Obstruction , Humans , Male , Aged , Female , Renal Artery/diagnostic imaging , Renal Artery/surgery , Retrospective Studies , Treatment Outcome , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/complications , Acute Kidney Injury/diagnosis , Acute Kidney Injury/etiology , Replantation/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Risk Factors , Postoperative Complications/etiology
19.
Nephrology (Carlton) ; 29(4): 230-234, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38109884

ABSTRACT

Renal artery stenosis is one of the common vascular diseases that cause hypertension in children. However, renal artery aneurysms and abdominal aortic aneurysms, which may be components of mid-aortic syndrome, are rarely associated with renal artery stenosis. Despite its rarity, early diagnosis and treatment are critical to prevent fatal complications. Currently, non-surgical invasive techniques are considered the first choice for treatment, but in some cases, surgery is inevitable. Here, we present a 5-year-old boy with a mid-aortic syndrome. The patient presented with a history of severe headache and epistaxis 5-6 times a day and was diagnosed with hypertension. A 9 × 9 mm saccular aneurysm on the anterior surface of the abdominal aorta at the level of the left renal artery ostium, and a 12 mm aneurysm in the left renal artery after a stenotic segment at the hilum level was detected in the doppler USG and contrast-enhanced imaging techniques. The patient was operated on electively. We used a PTFE patch to repair the abdominal aorta and, saphenous vein which was taken from his father to repair the renal artery. The patient recovered well and was discharged on the 18th day.


Subject(s)
Hypertension , Renal Artery Obstruction , Male , Child , Humans , Child, Preschool , Renal Artery Obstruction/diagnosis , Renal Artery Obstruction/diagnostic imaging , Antihypertensive Agents/therapeutic use , Renal Artery/diagnostic imaging , Renal Artery/surgery , Aorta, Abdominal/diagnostic imaging , Aorta, Abdominal/surgery , Hypertension/complications , Hypertension/diagnosis
SELECTION OF CITATIONS