Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Anal Chem ; 91(18): 11747-11756, 2019 09 17.
Article in English | MEDLINE | ID: mdl-31423767

ABSTRACT

Carbon isotope ratio (CIR) confirmation is one of the most complex and delicate analyses in the doping control field, due to the nature of the molecules to be confirmed, normally present in urinary samples as a consequence of an endogenous production. The requirements for method validation established by the World Anti-Doping Agency (WADA) have been pushing the accredited laboratories to improve their methods. The choice of the method is always a cost benefit ratio involving a hard-working and time-consuming analysis and the guarantee of reporting of reliable results. This work presents the method fully validated by the Brazilian Doping Control Laboratory as part of the preparation for the Rio de Janeiro Summer Olympic and Paralympic Games 2016. Sample preparation encompassed solid-phase extraction, liquid-liquid extraction, enzymatic hydrolysis, acetylation, and purification by preparative high-performance liquid chromatography, and analyses were performed by gas chromatography/combustion/isotope ratio mass spectrometry. This proved to be a robust method to CIR confirmation in a big event, as demonstrated by the analysis of 179 samples during the Games 2016, from clearly negative results and adverse findings for testosterone (T) and related substances, boldenone and its metabolite, 19-norandrosterone and formestane. Two atypical findings were also reported for T and metabolites.


Subject(s)
Carbon Isotopes/urine , Doping in Sports , Gas Chromatography-Mass Spectrometry/methods , Testosterone Congeners/urine , Acetylation , Brazil , Chromatography, High Pressure Liquid , Estranes/urine , Humans , Liquid-Liquid Extraction , Reproducibility of Results , Solid Phase Extraction , Sports , Testosterone/analogs & derivatives , Testosterone/urine
2.
Drug Test Anal ; 10(3): 507-517, 2018 Mar.
Article in English | MEDLINE | ID: mdl-28600878

ABSTRACT

This is a first look at a non-targeted screening method based on Orbitrap gas chromatography-mass spectrometry (GC-MS) technology for a large number of banned compounds in sports found in urine, including exogenous anabolic steroids, ß-agonists, narcotics, stimulants, hormone modulators, and diuretics. A simple sample preparation was processed in four steps: an enzymatic hydrolysis, liquid-liquid extraction, evaporation, and trimethylsilylation. All compounds were able to meet the World Anti-Doping Agency's sensitivity criteria with mass accuracies less than 1 ppm and with sufficient points across the peak by running the Orbitrap GC-MS in full-scan mode. In addition, we discuss our initial findings of using a full-scan selected ion monitoring-tandem mass spectrometry (SIM-MS/MS) approach as a way to obtain lower detection limits and reach desirable selectivity for some exogenous anabolic steroids.


Subject(s)
Anabolic Agents/urine , Gas Chromatography-Mass Spectrometry/methods , Substance Abuse Detection/methods , Testosterone Congeners/urine , Doping in Sports , Humans , Liquid-Liquid Extraction/methods , Tandem Mass Spectrometry/methods
SELECTION OF CITATIONS
SEARCH DETAIL