Results 1 - 20 de 15.992
Filter
1.
J Mater Chem B ; 12(25): 6190-6202, 2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38832839

ABSTRACT

Metal organic frameworks (MOFs) have garnered significant attention in the development of stretchable and wearable conductive hydrogels for flexible transducers. However, MOFs used in hydrogel networks have been hampered by low mechanical performance and poor dispersibility in aqueous solutions, which affect the performance of hydrogels, including low toughness, limited self-recovery, short working ranges, low conductivity, and prolonged response-recovery times. To address these shortcomings, a novel approach was adopted in which micelle co-polymerization was used for the ex situ synthesis of Zn-MOF-based hydrogels with exceptional stretchability, robust toughness, anti-fatigue properties, and commendable conductivity. This breakthrough involved the ex situ integration of Zn-MOFs into hydrophobically cross-linked polymer chains. Here the micelles of EHDDAB had two functions, first they uniformly dispersed the Zn-MOFs and secondly they dynamically cross-linked the polymer chains, profoundly influencing the mechanical characteristics of the hydrogels. The non-covalent synergistic interactions introduced by Zn-MOFs endowed the hydrogels with the capacity for high stretchability, high stress, rapid self-recovery, anti-fatigue properties, and conductivity, all achieved without external stimuli. Furthermore, hydrogels based on Zn-MOFs can serve as durable and highly sensitive flexible transducers, adept at detecting diverse mechanical deformations with swift response-recovery times and high gauge factor values. Consequently, these hydrogels can be tailored to function as wearable strain sensors capable of sensing significant human joint movements, such as wrist bending, and motions involving the wrist, fingers, and elbows. Similarly, they excel at monitoring subtle human motions, such as speech pronunciation, distinguishing between different words, as well as detecting swallowing and larynx vibrations during various activities. Beyond these applications, the hydrogels exhibit proficiency in distinguishing and reproducing various written words with reliability. The Zn-MOF-based hydrogels hold promising potential for development in electronic skin, medical monitoring, soft robotics, and flexible touch panels.


Subject(s)
Electric Conductivity , Hydrogels , Metal-Organic Frameworks , Wearable Electronic Devices , Hydrogels/chemistry , Humans , Metal-Organic Frameworks/chemistry , Zinc/chemistry , Transducers
2.
Sensors (Basel) ; 24(11)2024 May 27.
Article in English | MEDLINE | ID: mdl-38894228

ABSTRACT

Piezoelectric effects were first discovered more than a hundred years ago and, since then, have been widely used across various fields [...].


Subject(s)
Transducers , Humans , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods
3.
PLoS One ; 19(6): e0304489, 2024.
Article in English | MEDLINE | ID: mdl-38857262

ABSTRACT

Flow-induced vibrations (FIV) were considered as unwanted vibrations analogous to noise. However, in a recent trend, the energy of these vibrations can be harvested and converted to electrical power. In this study, the potential of FIV as a source of renewable energy is highlighted through experimental and numerical analyses. The experimental study was conducted on an elastically mounted circular cylinder using helical and leaf springs in the wind tunnel. The Reynolds number (Re) varied between 2300-16000. The motion of the cylinder was restricted in all directions except the transverse direction. The micro-electromechanical system (MEMS) was mounted on the leaf spring to harvest the mechanical energy. Numerical simulations were also performed with SST k-ω turbulence model to supplement the experiments and were found to be in good agreement with the experimental results. The flow separation and vortex shedding induce aerodynamic forces in the cylinder causing it to vibrate. 2S vortex shedding pattern was observed in all of the cases in this study. The maximum dimensionless amplitude of vibration (A/D) obtained was 0.084 and 0.068 experimentally and numerically, respectively. The results showed that the region of interest is the lock-in region where maximum amplitude of vibration is observed and, therefore, the maximum power output. The piezoelectric voltage and power output were recorded for different reduced velocities (Ur = 1-10) at different resistance values in the circuit. It was observed that as the amplitude of oscillation of the cylinder increases, the voltage and power output of the MEMS increases due to high strain in piezoelectric transducer. The maximum output voltage of 0.6V was observed at Ur = 4.95 for an open circuit, i.e., for a circuit with the resistance value of infinity. As the resistance value reduced, a drop in voltage output was observed. Maximum power of 10.5µW was recorded at Ur = 4.95 for a circuit resistance of 100Ω.


Subject(s)
Transducers , Vibration , Models, Theoretical , Renewable Energy , Micro-Electrical-Mechanical Systems/instrumentation , Computer Simulation
4.
Nat Commun ; 15(1): 4601, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38834558

ABSTRACT

Precise neurostimulation can revolutionize therapies for neurological disorders. Electrode-based stimulation devices face challenges in achieving precise and consistent targeting due to the immune response and the limited penetration of electrical fields. Ultrasound can aid in energy propagation, but transcranial ultrasound stimulation in the deep brain has limited spatial resolution caused by bone and tissue scattering. Here, we report an implantable piezoelectric ultrasound stimulator (ImPULS) that generates an ultrasonic focal pressure of 100 kPa to modulate the activity of neurons. ImPULS is a fully-encapsulated, flexible piezoelectric micromachined ultrasound transducer that incorporates a biocompatible piezoceramic, potassium sodium niobate [(K,Na)NbO3]. The absence of electrochemically active elements poses a new strategy for achieving long-term stability. We demonstrated that ImPULS can i) excite neurons in a mouse hippocampal slice ex vivo, ii) activate cells in the hippocampus of an anesthetized mouse to induce expression of activity-dependent gene c-Fos, and iii) stimulate dopaminergic neurons in the substantia nigra pars compacta to elicit time-locked modulation of nigrostriatal dopamine release. This work introduces a non-genetic ultrasound platform for spatially-localized neural stimulation and exploration of basic functions in the deep brain.


Subject(s)
Deep Brain Stimulation , Hippocampus , Ultrasonic Waves , Animals , Deep Brain Stimulation/instrumentation , Deep Brain Stimulation/methods , Mice , Mice, Inbred C57BL , Dopaminergic Neurons , Male , Dopamine/metabolism , Proto-Oncogene Proteins c-fos/metabolism , Substantia Nigra , Neurons/physiology , Transducers
5.
ACS Nano ; 18(24): 15607-15616, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38838347

ABSTRACT

Photothermal modulation of neural activity offers a promising approach for understanding brain circuits and developing therapies for neurological disorders. However, the low neuron selectivity and inefficient light-to-heat conversion of existing photothermal nanomaterials significantly limit their potential for neuromodulation. Here, we report that graphdiyne (GDY) can be developed into an efficient neuron-targeted photothermal transducer for in vivo modulation of neuronal activity through rational surface functionalization. We functionalize GDY with polyethylene glycol (PEG) through noncovalent hydrophobic interactions, followed by antibody conjugation to specifically target the temperature-sensitive transient receptor potential cation channel subfamily V member 1 (TRPV1) on the surface of neural cells. The nanotransducer not only exhibits high photothermal conversion efficiency in the near-infrared region but also shows great TRPV1-targeting capability. This enables photothermal activation of TRPV1, leading to neurotransmitter release in cells and modulation of neural firing in living mice. With its precision and selectivity, the GDY-based transducer provides an innovative avenue for understanding brain function and developing therapeutic strategies for neurodegenerative diseases.


Subject(s)
Neurons , TRPV Cation Channels , Animals , TRPV Cation Channels/metabolism , Neurons/metabolism , Mice , Humans , Graphite/chemistry , Graphite/pharmacology , Polyethylene Glycols/chemistry , Transducers
6.
Opt Lett ; 49(11): 3054-3057, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38824326

ABSTRACT

Photoacoustic imaging (PAI) utilizes the photoacoustic effect to record both vascular and functional characteristics of a biological tissue. Photoacoustic signals have typically low amplitude that cannot be read efficiently by data acquisition systems. This necessitates the use of one or more amplifiers. These amplifiers are somewhat bulky (e.g., the ZFL-500LN+, Mini-Circuits, USA, or 351A-3-50-NI, Analog Modules Inc., USA). Here, we describe the fabrication and development process of a transducer with a built-in low-noise preamplifier that is encased within the transducer housing. This new, to the best of our knowledge, design could be advantageous for applications where a compact transducer + preamplifier is required. We demonstrate the performance of this compact detection unit in a laser scanning photoacoustic microscopy system by imaging a rat ear ex vivo and a rat brain vasculature in vivo.


Subject(s)
Equipment Design , Photoacoustic Techniques , Transducers , Photoacoustic Techniques/instrumentation , Photoacoustic Techniques/methods , Animals , Rats , Miniaturization , Brain/diagnostic imaging , Brain/blood supply , Ear/diagnostic imaging , Ear/blood supply , Amplifiers, Electronic
7.
Ultrasound Med Biol ; 50(8): 1178-1182, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38705784

ABSTRACT

OBJECTIVE: Although hand-held ultrasound devices (HHUSDs) are currently used for a diverse range of diagnostic and interventional applications the imaging performance of such scanners is rarely considered. The aim of this study was to assess the imaging performance of a wide-range of HHUSDs and compare their imaging performance to cart-based systems utilized for the same clinical applications. METHODS: The grayscale imaging performances of 19 HHUSDs from eight different manufacturers, manufactured between 2016 and 2021, were measured using a figure-of-merit known as the resolution integral. The imaging performance of the HHUSDs were compared to 142 cart-based ultrasound scanners. RESULTS: The HHUSD with the overall highest resolution integral (66) was a Butterfly (Burlington, MA, USA) wired phased array for small parts applications, followed by a Philips (Bothell, WA, USA) Lumify wired curvilinear transducer (57) for abdominal applications, a Butterfly wired phased array (56) for abdominal applications, a GE (Freiburg, Baden-Wurttemberg, Germany) VScan Air wireless linear array (56) for small parts applications, and a Healcerion (Seoul, Korea) Sonon 300L wireless linear array (56) for small parts applications. A GE VScan Extend wired phased array had the highest resolution integral (44) for cardiac applications. CONCLUSIONS: The Butterfly phased array had the highest resolution integral of all the 19 HHUSDs, although this value is still less than the majority of cart-based cardiac and abdominal ultrasound scanners manufactured from 2010 to 2017. Clinical users of HHUSDs should be mindful of the limitations in imaging performance of hand-held ultrasound devices.


Subject(s)
Equipment Design , Phantoms, Imaging , Ultrasonography , Ultrasonography/instrumentation , Ultrasonography/methods , Transducers
8.
Aliment Pharmacol Ther ; 60(1): 70-82, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38693718

ABSTRACT

BACKGROUND: Obesity impacts the diagnostic accuracy of shear wave elastography (SWE). A deep abdominal ultrasound transducer (DAX) capable of point (pSWE) and two-dimensional (2D)-SWE has recently been introduced to address this issue. METHODS: We performed a prospective study in a cohort of mostly patients with obesity undergoing liver biopsy with a high prevalence of metabolic dysfunction-associate steatotic liver disease (MASLD). Liver stiffness measurement (LSM) was measured using vibration-controlled transient elastography (VCTE), as well as pSWE and 2D SWE on the standard (5C1) and the DAX transducers. RESULTS: We included 129 patients with paired LSM and liver biopsy: median age 44.0 years, 82 (63.6%) women, median BMI: 43.2 kg/m2. Histologic fibrosis stages: F0: N = 55 (42.6%), F1: N = 14 (10.9%), F2: N = 50 (38.8%), F3: N = 2 (1.6%), F4: N = 8 (6.2%). VCTE-LSM failed (N = 13) or were unreliable (IQR/median ≤30% in ≥7.1 kPa, N = 14) in 20.9% of patients. The Pearson correlation of reliable VCTE-LSM with both pSWE and 2D SWE was strong (all >0.78). The diagnostic accuracy for all LSM techniques was poor for significant fibrosis (≥F2, AUC: 0.54-0.63); however, it was good to excellent for advanced fibrosis (≥F3, AUC: 0.87-0.99) and cirrhosis (F4, AUC: 0.86-1.00). In intention-to-diagnose analysis, pSWE on DAX was significantly superior to VCTE-LSM. CONCLUSIONS: pSWE- and 2D-SWE enable the non-invasive identification of advanced fibrosis and cirrhosis in patients with obese MASLD. The use of the DAX transducer for acoustic radiation force imaging (ARFI)-LSM avoids technical failures in an obese population and subsequently offers advantages over VCTE-LSM for the evaluation of fibrosis in an obese MASLD population at risk for fibrosis.


Subject(s)
Elasticity Imaging Techniques , Liver Cirrhosis , Obesity , Humans , Elasticity Imaging Techniques/methods , Female , Male , Prospective Studies , Liver Cirrhosis/diagnostic imaging , Adult , Middle Aged , Obesity/complications , Biopsy/methods , Liver/diagnostic imaging , Liver/pathology , Transducers
9.
PLoS One ; 19(5): e0301007, 2024.
Article in English | MEDLINE | ID: mdl-38758827

ABSTRACT

Building on the Fano resonance observation, a new refractive index transducer structure at the nanoscale is proposed in this article, which is a refractive index transducer consisting of a metal-insulator-metal (MIM) waveguide structure coupled with a ring cavity internally connected to an h-shaped structure (RCIhS). Using an analytical method based on COMSOL software and finite element method (FEM), the effect of different geometric parameters of the structure on the trans-mission characteristics of the system is simulated and analyzed, which in turn illustrates the effect of the structural parameters on the output Fano curves. As simulation results show, the internally connected h-shaped structure is an influential component in the Fano resonance. By optimizing the geometrical parameters of the structure, the system finally accomplishes a sensitivity (S) of 2400 nm/RIU and a figure of merit (FOM) of 68.57. The sensor has also been demonstrated in the realm of temperature detection, having tremendous potential for utilization in future nano-sensing and optically integrated systems.


Subject(s)
Refractometry , Transducers , Finite Element Analysis , Equipment Design , Nanotechnology , Temperature
10.
Clin Oral Investig ; 28(5): 294, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38698252

ABSTRACT

OBJECTIVES: To compare ultrasonic scaler prototypes based on a planar piezoelectric transducer with different working frequencies featuring a titanium (Ti-20, Ti-28, and Ti-40) or stainless steel (SS-28) instrument, with a commercially available scaler (com-29) in terms of biofilm removal and reformation, dentine surface roughness and adhesion of periodontal fibroblasts. MATERIALS AND METHODS: A periodontal multi-species biofilm was formed on specimens with dentine slices. Thereafter specimens were instrumented with scalers in a periodontal pocket model or left untreated (control). The remaining biofilms were quantified and allowed to reform on instrumented dentine slices. In addition, fibroblasts were seeded for attachment evaluation after 72 h of incubation. Dentine surface roughness was analyzed before and after instrumentation. RESULTS: All tested instruments reduced the colony-forming unit (cfu) counts by about 3 to 4 log10 and the biofilm quantity (each p < 0.01 vs. control), but with no statistically significant difference between the instrumented groups. After 24-hour biofilm reformation, no differences in cfu counts were observed between any groups, but the biofilm quantity was about 50% in all instrumented groups compared to the control. The attachment of fibroblasts on instrumented dentine was significantly higher than on untreated dentine (p < 0.05), with the exception of Ti-20. The dentine surface roughness was not affected by any instrumentation. CONCLUSIONS: The planar piezoelectric scaler prototypes are able to efficiently remove biofilm without dentine surface alterations, regardless of the operating frequency or instrument material. CLINICAL RELEVANCE: Ultrasonic scalers based on a planar piezoelectric transducer might be an alternative to currently available ultrasonic scalers.


Subject(s)
Biofilms , Dental Scaling , Dentin , Fibroblasts , Periodontal Ligament , Surface Properties , Titanium , Humans , Dental Scaling/instrumentation , In Vitro Techniques , Dentin/microbiology , Periodontal Ligament/cytology , Transducers , Cell Adhesion , Stainless Steel , Equipment Design , Ultrasonic Therapy/instrumentation
11.
Sensors (Basel) ; 24(9)2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38732804

ABSTRACT

In general, it is difficult to visualize internal ocular structure and detect a lesion such as a cataract or glaucoma using the current ultrasound brightness-mode (B-mode) imaging. This is because the internal structure of the eye is rich in moisture, resulting in a lack of contrast between tissues in the B-mode image, and the penetration depth is low due to the attenuation of the ultrasound wave. In this study, the entire internal ocular structure of a bovine eye was visualized in an ex vivo environment using the compound acoustic radiation force impulse (CARFI) imaging scheme based on the phase-inverted ultrasound transducer (PIUT). In the proposed method, the aperture of the PIUT is divided into four sections, and the PIUT is driven by the out-of-phase input signal capable of generating split-focusing at the same time. Subsequently, the compound imaging technique was employed to increase signal-to-noise ratio (SNR) and to reduce displacement error. The experimental results demonstrated that the proposed technique could provide an acoustic radiation force impulse (ARFI) image of the bovine eye with a broader depth-of-field (DOF) and about 80% increased SNR compared to the conventional ARFI image obtained using the in-phase input signal. Therefore, the proposed technique can be one of the useful techniques capable of providing the image of the entire ocular structure to diagnose various eye diseases.


Subject(s)
Elasticity Imaging Techniques , Eye , Signal-To-Noise Ratio , Transducers , Animals , Cattle , Eye/diagnostic imaging , Elasticity Imaging Techniques/methods , Ultrasonography/methods
12.
Sensors (Basel) ; 24(9)2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38732775

ABSTRACT

Photoacoustic imaging (PAI) is a rapidly developing emerging non-invasive biomedical imaging technique that combines the strong contrast from optical absorption imaging and the high resolution from acoustic imaging. Abnormal biological tissues (such as tumors and inflammation) generate different levels of thermal expansion after absorbing optical energy, producing distinct acoustic signals from normal tissues. This technique can detect small tissue lesions in biological tissues and has demonstrated significant potential for applications in tumor research, melanoma detection, and cardiovascular disease diagnosis. During the process of collecting photoacoustic signals in a PAI system, various factors can influence the signals, such as absorption, scattering, and attenuation in biological tissues. A single ultrasound transducer cannot provide sufficient information to reconstruct high-precision photoacoustic images. To obtain more accurate and clear image reconstruction results, PAI systems typically use a large number of ultrasound transducers to collect multi-channel signals from different angles and positions, thereby acquiring more information about the photoacoustic signals. Therefore, to reconstruct high-quality photoacoustic images, PAI systems require a significant number of measurement signals, which can result in substantial hardware and time costs. Compressed sensing is an algorithm that breaks through the Nyquist sampling theorem and can reconstruct the original signal with a small number of measurement signals. PAI based on compressed sensing has made breakthroughs over the past decade, enabling the reconstruction of low artifacts and high-quality images with a small number of photoacoustic measurement signals, improving time efficiency, and reducing hardware costs. This article provides a detailed introduction to PAI based on compressed sensing, such as the physical transmission model-based compressed sensing method, two-stage reconstruction-based compressed sensing method, and single-pixel camera-based compressed sensing method. Challenges and future perspectives of compressed sensing-based PAI are also discussed.


Subject(s)
Algorithms , Photoacoustic Techniques , Photoacoustic Techniques/methods , Humans , Image Processing, Computer-Assisted/methods , Diagnostic Imaging/methods , Transducers
13.
Nat Commun ; 15(1): 4017, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38740759

ABSTRACT

Ultrasound-driven bioelectronics could offer a wireless scheme with sustainable power supply; however, current ultrasound implantable systems present critical challenges in biocompatibility and harvesting performance related to lead/lead-free piezoelectric materials and devices. Here, we report a lead-free dual-frequency ultrasound implants for wireless, biphasic deep brain stimulation, which integrates two developed lead-free sandwich porous 1-3-type piezoelectric composite elements with enhanced harvesting performance in a flexible printed circuit board. The implant is ultrasonically powered through a portable external dual-frequency transducer and generates programmable biphasic stimulus pulses in clinically relevant frequencies. Furthermore, we demonstrate ultrasound-driven implants for long-term biosafety therapy in deep brain stimulation through an epileptic rodent model. With biocompatibility and improved electrical performance, the lead-free materials and devices presented here could provide a promising platform for developing implantable ultrasonic electronics in the future.


Subject(s)
Deep Brain Stimulation , Wireless Technology , Deep Brain Stimulation/instrumentation , Deep Brain Stimulation/methods , Animals , Wireless Technology/instrumentation , Rats , Electrodes, Implanted , Epilepsy/therapy , Male , Prostheses and Implants , Rats, Sprague-Dawley , Transducers , Equipment Design , Ultrasonic Waves
14.
Article in English | MEDLINE | ID: mdl-38635378

ABSTRACT

Thin-film piezoelectric micromachined ultrasound transducers (PMUTs) are an increasingly relevant and well-researched field, and their biomedical importance has been growing as the technology continues to mature. This review article briefly discusses their history in biomedical use, provides a simple explanation of their principles for newer readers, and sheds light on the materials selection for these devices. Primarily, it discusses the significant applications of PMUTs in the biomedical industry and showcases recent progress that has been made in each application. The biomedical applications covered include common historical uses of ultrasound such as ultrasound imaging, ultrasound therapy, and fluid sensing, but additionally new and upcoming applications such as drug delivery, photoacoustic imaging, thermoacoustic imaging, biometrics, and intrabody communication. By including a device comparison chart for different applications, this review aims to assist microelectromechanical systems (MEMS) designers that work with PMUTs by providing a benchmark for recent research works. Furthermore, it puts forth a discussion on the current challenges being faced by PMUTs in the biomedical field, current and likely future research trends, and opportunities for PMUT development areas, as well as sharing the opinions and predictions of the authors on the state of this technology as a whole. The review aims to be a comprehensive introduction to these topics without diving excessively deep into existing literature.


Subject(s)
Equipment Design , Transducers , Ultrasonography , Ultrasonography/instrumentation , Ultrasonography/methods , Humans , Micro-Electrical-Mechanical Systems/instrumentation , Microtechnology/instrumentation
15.
Sci Adv ; 10(16): eadj0268, 2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38640247

ABSTRACT

Continuous monitoring of biomarkers at locations adjacent to targeted internal organs can provide actionable information about postoperative status beyond conventional diagnostic methods. As an example, changes in pH in the intra-abdominal space after gastric surgeries can serve as direct indicators of potentially life-threatening leakage events, in contrast to symptomatic reactions that may delay treatment. Here, we report a bioresorbable, wireless, passive sensor that addresses this clinical need, designed to locally monitor pH for early detection of gastric leakage. A pH-responsive hydrogel serves as a transducer that couples to a mechanically optimized inductor-capacitor circuit for wireless readout. This platform enables real-time monitoring of pH with fast response time (within 1 hour) over a clinically relevant period (up to 7 days) and timely detection of simulated gastric leaks in animal models. These concepts have broad potential applications for temporary sensing of relevant biomarkers during critical risk periods following diverse types of surgeries.


Subject(s)
Absorbable Implants , Transducers , Animals , Wireless Technology , Hydrogen-Ion Concentration , Biomarkers
16.
Anal Chim Acta ; 1305: 342590, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38677844

ABSTRACT

Monitoring extracellular calcium ion (Ca2+) chemical signals in neurons is crucial for tracking physiological and pathological changes associated with brain diseases in live animals. Potentiometry based solid-state ion-selective electrodes (ISEs) with the assist of functional carbon nanomaterials as ideal solid-contact layer could realize the potential response for in vitro and in vivo analysis. Herein, we employ a kind of biomass derived porous carbon as a transducing layer to prompt efficient ion to electron transduction while stabilizes the potential drift. The eco-friendly porous carbon after activation (APB) displays a high specific area with inherit macropores, micropores, and large specific capacitance. When employed as transducer in ISEs, a stable potential response, minimized potential drift can be obtained. Benefiting from these excellent properties, a solid-state Ca2+ selective carbon fiber electrodes (CFEs) with a sandwich structure is constructed and employed for real time sensing of Ca2+ under electrical stimulation. This study presents a new approach to develop sustainable and versatile transducers in solid-state ISEs, a crucial way for in vivo sensing.


Subject(s)
Calcium , Carbon , Nanostructures , Calcium/chemistry , Calcium/analysis , Carbon/chemistry , Nanostructures/chemistry , Ion-Selective Electrodes , Animals , Porosity , Transducers , Electrochemical Techniques/instrumentation
17.
Ultrason Imaging ; 46(3): 186-196, 2024 May.
Article in English | MEDLINE | ID: mdl-38647142

ABSTRACT

Conventional B-mode ultrasound imaging has difficulty in delineating homogeneous soft tissues with similar acoustic impedances, as the reflectivity depends on the acoustic impedance at the interface. As a quantitative imaging biomarker sensitive to alteration of biomechanical properties, speed-of-sound (SoS) holds promising potential for tissue and disease differentiation such as delineation of different breast tissue types with similar acoustic impedance. Compared to two-dimensional (2D) SoS images, three-dimensional (3D) volumetric SoS images achieved through a full-angle ultrasound scan can reveal more intricate morphological structures of tissues; however, they generally require a ring transducer. In this study, we introduce a 3D SoS reconstruction system that utilizes hand-held linear arrays instead. This system employs a passive reflector positioned opposite the linear arrays, serving as an echogenic reference for time-of-flight (ToF) measurements, and a high-definition camera to track the location corresponding to each group of transmit-receive data. To merge these two streams of ToF measurements and location tracking, a voxel-based reconstruction algorithm is implemented. Experimental results with gelatin phantom and ex vivo tissue have demonstrated the stability of our proposed method. Moreover, the results underscore the potential of this system as a complementary diagnostic modality, particularly in the context of diseases such as breast cancer.


Subject(s)
Imaging, Three-Dimensional , Phantoms, Imaging , Ultrasonography , Ultrasonography/methods , Imaging, Three-Dimensional/methods , Animals , Algorithms , Transducers , Equipment Design , Humans , Female
18.
Comput Methods Programs Biomed ; 250: 108169, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38643604

ABSTRACT

BACKGROUND AND OBJECTIVE: Computational Ultrasound Imaging (CUI) has become increasingly popular in the medical ultrasound community, facilitated by free simulation software. These tools enable the design and exploration of transmit sequences, transducer arrays, and signal processing. We recently introduced SIMUS, a frequency-based ultrasound simulator within the open-source MUST toolbox, which offers numerical advantages and allows easy consideration of frequency-dependent factors. In response to the growing interest in simulating ultrasound imaging with 2-D matrix arrays, we present 3-D versions, PFIELD3 and SIMUS3. METHOD: The linear acoustic equations driving these functions are described, with theoretical assumptions reviewed for user guidance. RESULTS: Comparative analyses with Field II, using a 32×32 element 3-MHz matrix array, highlight the performance of PFIELD3 and SIMUS3 under various transmission conditions. CONCLUSIONS: This work extends the capabilities of existing CUI tools and provides researchers with valuable resources for advanced ultrasound simulations.


Subject(s)
Computer Simulation , Imaging, Three-Dimensional , Software , Ultrasonography , Ultrasonography/methods , Humans , Transducers , Algorithms , Phantoms, Imaging
19.
Phys Med Biol ; 69(9)2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38518377

ABSTRACT

Objective.Histotripsy is a noninvasive focused ultrasound therapy that mechanically disintegrates tissue by acoustic cavitation clouds. In this study, we investigate a mechanism limiting the density of bubbles that can nucleate during a histotripsy pulse. In this mechanism, the pressure generated by the initial bubble expansion effectively negates the incident pressure in the vicinity of the bubble. From this effect, the immediately adjacent tissue is prevented from experiencing the transient tension to nucleate bubbles. Approach.A Keller-Miksis-type single-bubble model was employed to evaluate the dependency of this effect on ultrasound pressure amplitude and frequency, viscoelastic medium properties, bubble nucleus size, and transducer geometric focusing. This model was further combined with a spatial propagation model to predict the peak negative pressure field as a function of position from a cavitating bubble.Main results. The single-bubble model showed the peak negative pressure near the bubble surface is limited to the inertial cavitation threshold. The predicted bubble density increased with increasing frequency, tissue viscosity, and transducer focusing angle. The simulated results were consistent with the trends observed experimentally in prior studies, including changes in density with ultrasound frequency and transducerF-number.Significance.The efficacy of the therapy is dependent on several factors, including the density of bubbles nucleated within the cavitation cloud formed at the focus. These results provide insight into controlling the density of nucleated bubbles during histotripsy and the therapeutic efficacy.


Subject(s)
High-Energy Shock Waves , High-Intensity Focused Ultrasound Ablation , Lithotripsy , High-Intensity Focused Ultrasound Ablation/methods , Lithotripsy/methods , Ultrasonography , Transducers
20.
Ultrasound Med Biol ; 50(6): 775-778, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38485533

ABSTRACT

The COVID-19 pandemic highlighted the importance of infection prevention and control measures for all medical procedures, including ultrasound examinations. As the use of ultrasound increases across more medical modalities, including point-of-care ultrasound, so does the risk of possible transmission from equipment to patients and patients to patients. This is particularly relevant for endocavity transducers, such as trans-vaginal, trans-rectal and trans-oesophageal, which could be contaminated with organisms from blood, mucosal, genital or rectal secretions. This article proports to update the WFUMB 2017 guidelines which focussed on the cleaning and disinfection of trans-vaginal ultrasound transducers between patients.


Subject(s)
COVID-19 , Disinfection , Equipment Contamination , Transducers , Ultrasonography , Humans , COVID-19/transmission , COVID-19/prevention & control , Disinfection/methods , Equipment Contamination/prevention & control , Infection Control/methods , Infection Control/standards , Point-of-Care Systems , Practice Guidelines as Topic , SARS-CoV-2 , Ultrasonography/methods , Ultrasonography/instrumentation