ABSTRACT
This work reports the virucidal properties of nonwoven fibers developed via electrospinning with polycaprolactone (PCL) and chitosan quaternized with phosphonium salt (NPCS), emphasizing the influence of NPCS concentration on the structure of fibers and their performance against the MHV-3 coronavirus. The addition of NPCS enhances solutions conductivity and viscosity, leading to fibers containing a finer porous structure with a more hydrophilic and smoother surface, thereby making them a potent barrier against respiratory particles, which is a key factor for protective face masks. In terms of degradation, NPCS paced-up the process, suggesting potential environmental benefits. PCL/NPCS (90/10) fibers exhibit a 99 % coronavirus inhibition within a five-minute exposure without cellular toxicity, while also meeting breathability standards for medical masks. These findings suggest the use of NPCS as a promising strategy to design materials with remarkable virucidal performance and physical characteristics that reinforce their use in the field of biomaterials engineering.
Subject(s)
Antiviral Agents , Chitosan , Polyesters , Chitosan/chemistry , Chitosan/pharmacology , Polyesters/chemistry , Antiviral Agents/chemistry , Antiviral Agents/pharmacology , Animals , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , HumansABSTRACT
INTRODUCTION: The aim of the study was to evaluate the macular thickness of glaucomatous patients undergoing trabeculectomy (TREC) with mitomycin C (MMC) with or without the use of prostaglandin analog (PA) eye drops. METHODS: In this prospective, comparative clinical trial, patients with glaucoma and indications for TREC with MMC using PA and without previous macular changes were randomized into 2 groups: the study group (SG) and the control group (CG). In the CG, PA was suspended between 30 and 60 days after the preoperative exams. The subjects were evaluated, including optical coherence tomography (OCT) with the Cirrus 4000 macular protocol preoperatively and in the postoperative period on 3 occasions: 1-3 days ("PO1"), 6-9 days ("PO7"), and 27-30 days ("PO30") after surgery. The results were compared between groups. RESULTS: Thirty-five eyes of 35 patients were included (17 in the CG and 18 in the SG). There was no statistically significant difference in age (p = 0.2), the preoperative visual field mean deviation (p = 0.08), or the preoperative intraocular pressure (SG: 24.8 ± 7.8 mm Hg vs. CG: 22.8 ± 6.0 mm Hg, p = 0.4). The preoperative macular OCT parameters were equivalent between the groups (p > 0.05). When comparing the variation of parameters between the groups between preop and PO30 there was equivalence in all of the comparisons evaluated. The presence (or absence) of the lens did not affect the results. CONCLUSION: PA eye drops did not affect macular thickness after TREC with MMC in glaucomatous patients.
Subject(s)
Glaucoma , Intraocular Pressure , Macula Lutea , Mitomycin , Ophthalmic Solutions , Tomography, Optical Coherence , Trabeculectomy , Humans , Trabeculectomy/methods , Prospective Studies , Mitomycin/administration & dosage , Male , Female , Tomography, Optical Coherence/methods , Middle Aged , Intraocular Pressure/physiology , Glaucoma/surgery , Glaucoma/physiopathology , Glaucoma/diagnosis , Macula Lutea/pathology , Macula Lutea/diagnostic imaging , Aged , Prostaglandins, Synthetic/administration & dosage , Prostaglandins, Synthetic/therapeutic use , Visual Acuity , Alkylating Agents/administration & dosage , AdultABSTRACT
ABSTRACT Purpose: To longitudinally compare isolated structural parameters obtained using RTVue optical coherence tomography in patients with glaucoma and suspected glaucoma with stable visual fields. Methods: All patients were required to have a reliable SITA Standard 24-2 Humphrey Visual Field test. Visual field stability was defined as having <5 points with p<5% and/or having no points with p<1% and/or p<0.05% in the glaucoma progression analysis comparison graph. Furthermore, the glaucoma assessment strategy was used in optical coherence tomography. Results: The study included 75 eyes from 75 patients, 43 of which had glaucoma and 32 had suspected glaucoma. The mean visual field intervals were 29.57 ± 9.65 months between the first and third tests. No visual field parameter variations (mean deviation, pattern standard deviation, and visual field index) and no retinal nerve fiber layer or optic disk parameter variations between the first and third tests were observed (p>0.05 for all), and no retinal nerve fiber layer parameter variations throughout the study were observed, except for optic disk parameters presenting with cup volume changes (p=0.004). However, ganglion complex cells presented a progressively decreased average ganglion cell complex parameter, with a variability of -0.98% ± 3.71% (p=0.04) between the first and third tests. By contrast, the global loss volume progressively increased throughout the study, with a variability of 14.71% ± 44.52% (p=0.04) between the first and third tests. The inferior ganglion cell complex parameter was significantly decreased between the first and third tests (p=0.02). Conclusion: The present findings suggest that patients with glaucoma or suspected glaucoma with stable visual fields may present structural ganglion complex cell progression as assessed using RTVue optical coherence tomography.
RESUMO Objetivo: Comparar longitudinalmente os parâmetros estruturais isolados obtidos através da tomografia de coerência óptica RTVue em pacientes glaucomatosos e suspeitos de glaucoma com campos visuais estáveis. Métodos: Todos os incluídos deveriam ter Campimetria Computadorizada Humphrey Sita Standard 24-2 confiáveis. A estabilidade campimétrica foi definida se apresentassem menos de cinco pontos com p<5% e/ou nenhum ponto com p<1% e/ou p<0,05% no gráfico de comparação do Glaucoma Progression Analysis. Para a tomografia de coerência óptica, foi utilizado a estratégia de avaliação para glaucoma. Resultados: Foram incluídos 75 olhos de 75 pacientes: 43 com glaucoma e 32 suspeitos. A média dos intervalos do campo visual entre o 1o e 3o exame, foi de 29,57 ± 9,65 meses. Não houve variação para os parâmetros do campo visual (desvio médio, desvio padrão e índice da função visual) entre o primeiro e o último exame (p>0,05 para todos). Não houve variação dos parâmetros da camada de fibras nervosas da retina ao longo do estudo, enquanto que para os parâmetros do disco óptico, apenas cup volume apresentou mudança (p=0,004). Em relação à camada de células ganglionares da retina, notou-se uma redução progressiva na espessura média da Ganglionar Complex Cells com uma variabilidade entre o primeiro e último exame de -0,98 ± 3,71% (p=0,04). Quanto ao Global loss volume, houve um aumento progressivo ao longo do estudo com uma variabilidade entre o primeiro e último exame de 14,71 ± 44,52% (p=0,04). O parâmetro inferior do Ganglionar Complex Cells também reduziu significativamente entre o 1o e 3o exames (p=0,02). Os demais parâmetros da tomografia de coerência óptica RTVue se mantiveram estáveis entre o 1o e 3o exames. Conclusão: Os presentes achados sugerem que pacientes glaucomatosos ou com suspeita de glaucoma e com campos visuais estáveis, podem apresentar progressão estrutural na camada de células ganglionares da retina avaliada por meio da tomografia de coerência óptica RTVue.
ABSTRACT
BACKGROUND: The purpose of this study was to compare the impact of intravitreal dexamethasone (DEX) implant during a 12-month period in nondiabetic and diabetic patients without diabetic retinopathy (DR) as a treatment for refractory pseudophakic cystoid macular edema (PCME) following prior treatment with topical nepafenac 0.1% and prednisolone 1%. METHODS: Forty-two consecutive medical records of patients diagnosed with PCME after uneventful cataract surgery were included. The outcomes measured included best corrected visual acuity (BCVA) and central foveal thickness (CFT). Linear regression analysis was statistically applied. RESULTS: Following topical treatment, nondiabetic and diabetic subjects presented a mean ± SD gain of - 0.11 ± 0.11 and - 0.18 ± 0.11 BCVA logMAR and a CFT reduction of - 43.42 ± 53.66 µm and - 58.76 ± 36.28 µm, respectively. The mean BCVA gain at month 12 subsequent to DEX implantation was - 0.35 ± 0.17 in nondiabetic (p < 0.001) and - 0.55 ± 0.26 in diabetic patients (p < 0.001), with CFT reductions of - 195.71 ± 93.23 µm (p < 0.001) and - 260.81 ± 198.69 µm (p < 0.001), respectively. Patients who responded with better VA after topical treatment presented better visual outcomes at month 12 following DEX implantation (r2 = 0.46; rho = - 0.71, p < 0.01). CONCLUSION: Nondiabetic and diabetic patients without DR demonstrated similar results after DEX implant after combined topical therapy, suggesting that selected diabetic patients may have a response comparable to that of nondiabetic patients with PCME.
ABSTRACT
Despite the worldwide vaccination effort against COVID-19, the demand for biocidal materials has increased. One promising solution is the chemical modification of polysaccharides, such as chitosan, which can provide antiviral activity through the insertion of cationic terminals. In this study, chitosan was modified with (4-carboxybutyl) triphenylphosphonium bromide to create N-phosphonium chitosan (NPCS), a quaternized derivative. The resulting NPCS samples with three degrees of substitution (15.6 %, 19.8 % and 24.2 %) were characterized and found to have improved solubility in water and alkaline solutions but reduced thermal stability. The particles zeta potential exhibits positive charges and is directly correlated with the degree of substitution of the derivative. In virucidal assays, all NPCS samples were able to inhibit 99.999 % of the MHV-3 coronavirus within 5 min at low concentrations of 0.1 mg/mL, while maintaining low cytotoxicity to L929 cells. In addition to its potential application against current coronavirus strains, NPCS could also be valuable in combating future pandemics caused by other viral pathogens. The antiviral properties of NPCS make it a promising material for use in coating surface and personal protective equipment to limit the spread of disease-causing viruses.
Subject(s)
COVID-19 , Chitosan , Viruses , Humans , Chitosan/chemistry , Antiviral Agents/pharmacologyABSTRACT
ABSTRACT We report the case of a 39-year-old male patient who presented with visual loss in the right eye for 6 weeks. The best-corrected visual acuity was counting fingers in the right eye and 20/30 in the left eye. The fundus examination demonstrated a right retinal detachment inferiorly extending to the fovea and a left macular serous detachment. After multimodal imaging study, the patient was diagnosed as having a bullous variant of central serous chorioretinopathy and treated with oral spironolactone associated with adjuvant laser photocoagulation. The retinal changes resolved after 6 months. The final visual acuity was 20/20 in both eyes.
RESUMO Relatamos o caso de um homem de 39 anos apresentando perda visual no olho direito há seis semanas. A melhor acuidade visual corrigida foi conta-dedos no olho direito e 20/30 no esquerdo. A fundoscopia demonstrou descolamento de retina direito inferiormente com extensão à fóvea e descolamento macular seroso à esquerda. Após estudos de imagem multimodal, o paciente foi diagnosticado com uma variante bolhosa de coriorretinopatia serosa central e tratado com espironolactona oral associada à fotocoagulação a laser adjuvante. As alterações retinianas resolveram após seis meses. A acuidade visual final foi 20/20 em ambos os olhos.
ABSTRACT
Objective: Investigate the prevalence of postural changes and correlate them with body weight and the weight of schoolchildren's backpacks in a school in the city of São João del-Rei-MG. Material and. Methods: The study is an original type, with a cross-sectional design, where 109 schoolchildren of both sexes and mean age of 13 years were evaluated. The New York scale was used for posture analysis, measuring body weight, height, backpack weight, and Body Mass Index (BMI). The ANOVA statistical test and Pearson's correlation test were used, considering a significance level of 0.05. Results: According to the results, the general average of the scores of postural problems was 68.7 points, with a predominance in the head, spine, hips, trunk, and abdomen. The regions of shoulder, feet, and neck presented mean scores below seven. The mean height was 1.61 m, body weight 56.03 kg, backpack weight 4.49 kg and BMI was 21.51 kg/m. Conclusion: Postural alterations are highly prevalent among the evaluated students. The most affected body segments are the head, spine, hips, trunk, and abdomen. However, this finding was not related to the weight of the backpacks or the students' body weight. However, different parameters must be used to analyze the factors that may be related to such findings, such as ergonomic changes, inadequate habits, growth spurt, among others. Evidence Level III,Cross-sectional Observational Study.
Objetivo: Investigar a prevalência de alterações posturais e correlacionar com o peso corporal e o peso das mochilas dos escolares em uma escola no município de São João del-Rei-MG. Métodos: O estudo é do tipo original, com delineamento transversal onde foram avaliados 109 escolares, com média de idade de 13 anos, de ambos os sexos. A escala de Nova Iorque foi utilizada para análise de postura, medição do peso corporal, altura, peso da mochila e Índice de Massa Corporal (IMC). Foi utilizado o teste estatístico ANOVA e o teste de correlação de Pearson, considerando o nível de significância de 0,05. Resultados: De acordo com os resultados, a média geral dos escores dos problemas posturais foi de 68,7 pontos, com predomínio na região da cabeça, coluna, nos quadris, no tronco, e no abdômen. As regiões dos ombros, pés e pescoço apresentaram médias de escores menores que 7. A média da altura foi de 1,61m, do peso corporal de 56,03kg, do peso das mochilas de 4,49 kg e 21,51 kg/m do IMC. Conclusão: Conclui-se que existe uma alta prevalência de alterações posturais entre os escolares avaliados. Sendo que, os segmentos corporais mais comprometidos são, a cabeça, a coluna vertebral, os quadris, o tronco e o abdômen. No entanto, esse achado não foi relacionado ao peso das mochilas ou ao peso corporal dos escolares. Assim, diferentes parâmetros devem ser utilizados para analisar os fatores que podem estar relacionados a tais achados, como alterações ergonômicas, hábitos inadequados, estirão de crescimento, entre outros. Nível de Evidência III, Estudo Transversal Observacional.
ABSTRACT
This study aimed to estimate the risks of adverse infant outcomes in the first year of life related to prenatal Zika virus (ZIKV) exposure. A prospective cohort of pregnant women with rash was recruited in Central-West Brazil in a post-epidemic period (January 2017 to April 2019). We evaluated participants' medical histories and performed ZIKV diagnostic testing using molecular (reverse transcription polymerase chain reaction [RT-PCR]) and serologic (immunoglobulin [Ig]M and plaque reduction neutralization tests [PRNT90]) assays. The ZIKV-positive group included both RT-PCR-confirmed cases as well as IgM and/or PRNT90-positive probable cases. Children were evaluated at birth and in the first 12 months of life. Transfontanellar ultrasound, central nervous system computed tomography, eye fundoscopy and retinography were performed. We estimated the absolute risk and 95% confidence interval (95% CI) of adverse infant outcomes among confirmed prenatally ZIKV-exposed children. Among 81 pregnant women with rash, 43 (53.1%) were ZIKV infected. The absolute risk of microcephaly among offspring of ZIKV-infected pregnant women was 7.0% (95% CI: 1.5-19.1), including the two cases of microcephaly detected prenatally and one detected postnatally. In total, 54.5% (95% CI: 39.8-68.7) of children in the ZIKV-exposed group had at least one ophthalmic abnormality, with the most frequent abnormalities being focal pigmentary mottling and chorioretinal atrophy or scarring. Our findings reinforce the importance of long-term monitoring of prenatally ZIKV-exposed children born apparently asymptomatic for Congenital Zika Syndrome.
Subject(s)
Exanthema , Microcephaly , Pregnancy Complications, Infectious , Zika Virus Infection , Zika Virus , Infant, Newborn , Child , Humans , Pregnancy , Infant , Female , Zika Virus Infection/complications , Zika Virus Infection/diagnosis , Zika Virus Infection/epidemiology , Microcephaly/epidemiology , Microcephaly/etiology , Pregnancy Complications, Infectious/epidemiology , Prospective Studies , Brazil/epidemiology , Parturition , Exanthema/epidemiology , Exanthema/etiologyABSTRACT
PURPOSE: To longitudinally compare isolated structural parameters obtained using RTVue optical coherence tomography in patients with glaucoma and suspected glaucoma with stable visual fields. METHODS: All patients were required to have a reliable SITA Standard 24-2 Humphrey Visual Field test. Visual field stability was defined as having <5 points with p<5% and/or having no points with p<1% and/or p<0.05% in the glaucoma progression analysis comparison graph. Furthermore, the glaucoma assessment strategy was used in optical coherence tomography. RESULTS: The study included 75 eyes from 75 patients, 43 of which had glaucoma and 32 had suspected glaucoma. The mean visual field intervals were 29.57 ± 9.65 months between the first and third tests. No visual field parameter variations (mean deviation, pattern standard deviation, and visual field index) and no retinal nerve fiber layer or optic disk parameter variations between the first and third tests were observed (p>0.05 for all), and no retinal nerve fiber layer parameter variations throughout the study were observed, except for optic disk parameters presenting with cup volume changes (p=0.004). However, ganglion complex cells presented a progressively decreased average ganglion cell complex parameter, with a variability of -0.98% ± 3.71% (p=0.04) between the first and third tests. By contrast, the global loss volume progressively increased throughout the study, with a variability of 14.71% ± 44.52% (p=0.04) between the first and third tests. The inferior ganglion cell complex parameter was significantly decreased between the first and third tests (p=0.02). CONCLUSION: The present findings suggest that patients with glaucoma or suspected glaucoma with stable visual fields may present structural ganglion complex cell progression as assessed using RTVue optical coherence tomography.
ABSTRACT
A poloxamer 407 (P407)-Casein hydrogel was chosen to carry polycaprolactone nanoparticles carrying terbinafine (PCL-TBH-NP). In this study, terbinafine hydrochloride (TBH) was encapsulated into polycaprolactone (PCL) nanoparticles, which were further incorporated into a poloxamer-casein hydrogel in a different addition order to evaluate the effect of gel formation. Nanoparticles were prepared by the nanoprecipitation technique and characterized by evaluating their physicochemical characteristics and morphology. The nanoparticles had a mean diameter of 196.7 ± 0.7 nm, PDI of 0.07, negative ζ potential (-0.713 mV), high encapsulation efficiency (>98%), and did not show cytotoxic effects in primary human keratinocytes. PCL-NP modulated terbinafine was released in artificial sweat. Rheological properties were analyzed by temperature sweep tests at different addition orders of nanoparticles into hydrogel formation. The rheological behavior of nanohybrid hydrogels showed the influence of TBH-PCL nanoparticles addition in the mechanical properties of the hydrogel and a long-term release of the nanoparticles from it.
ABSTRACT
ABSTRACT We describe the case of a 15-year-old girl with decreased visual acuity associated with elevated intraocular pressure in both eyes and angle closure on gonioscopy. She also presented attenuation of retinal vessels and optic disc pallor with large excavation in the left eye. Ultrasound biomicroscopy revealed an anteriorly positioned ciliary body and absence of ciliary sulcus, confirming the plateau iris configuration. Spectral-domain optical coherence tomography revealed a bilateral cystoid macular edema. Genetic screening revealed heterozygous variants of the Crumbs homolog 1 (CRB1) gene (c.2843G>A and c.2506C>A). The patient underwent trabeculectomy for intraocular pressure control and topical treatment for macular edema. This case highlights the importance of performing gonioscopy and evaluating intraocular pressure in patients with a shallow anterior chamber despite young age. In addition, it also shows the importance of genetic screening, when available, in elucidating the diagnosis and providing patients and their families' information on the patient's prognosis and possible therapeutic options.
RESUMO Nós descrevemos um caso de uma paciente de 15 anos com queda de acuidade visual e aumento da pressão intraocular em ambos os olhos, juntamente com fechamento angular no exame de gonioscopia. Na fundoscopia a paciente apresentava atenuação dos vasos retinianos, palidez de disco e aumento de escavação em olho esquerdo. Ao exame da biomicroscopia ultrassônica, foi evidenciado corpo ciliar anteriorizado e ausência de sulco ciliar em ambos os olhos, relevando presença de íris em plateau. Ao exame de tomografia de coerência óptica, visualizamos presença de edema macular cistoide bilateral. O screening genético revelou heterozigose no gene CRB1 (c.2843G>A and c.2506C>A), confirmando o diagnóstico de retinose pigmentar. Este caso reforça a importância do exame de gonioscopia e da avaliação da pressão intraocular em pacientes em câmara rasa, mesmo em pacientes jovens. Além disso, mostra a importância do screening genético como ferramenta útil para elucidação diagnóstica.
Subject(s)
Humans , Adolescent , Glaucoma, Angle-Closure , Retinitis Pigmentosa , Glaucoma, Angle-Closure/surgery , Glaucoma, Angle-Closure/genetics , Retinitis Pigmentosa/complications , Retinitis Pigmentosa/genetics , Eye Proteins/genetics , Membrane Proteins , Nerve Tissue ProteinsABSTRACT
In this study, we aimed to analyze the effect of 5-fluorouracil, triamcinolone, and bevacizumab on scar modulation in an experimental rat model of surgical lesions. Rats (Rattus norvegicus albinus) were divided into four groups: bevacizumab, 5-fluorouracil + triamcinolone, bevacizumab + 5-fluorouracil + triamcinolone, and control (received no medication) groups. A linear, dorsal incision was created and sutured for the first intention wound healing, mimicking the surgical incision of upper blepharoplasty. Treatments were initiated on day 7, and the rats were euthanized on day 14. Only in the 5-fluorouracil + triamcinolone group was there a difference in the number of infiltrated monocytes. There was 56%, 86%, and 85% decrease in the number of neovessels in the bevacizumab, 5-fluorouracil + triamcinolone, and bevacizumab + 5-fluorouracil + triamcinolone groups, respectively, compared with the control. Picrosirius red staining showed higher collagen density and more organized collagen in the treatment groups than in the control group. Scar modulation was observed in all groups, but the 5-fluorouracil + triamcinolone group presented the best results. To our knowledge, this is the first study to evaluate the influence of three medications in combination on healing. When used together, these medications can prevent the development of unsightly scars, and are therefore promising alternatives to corticosteroids.
Subject(s)
Cicatrix, Hypertrophic , Surgical Wound , Rats , Animals , Triamcinolone/pharmacology , Triamcinolone/therapeutic use , Fluorouracil/pharmacology , Fluorouracil/therapeutic use , Bevacizumab/pharmacology , Bevacizumab/therapeutic use , Surgical Wound/drug therapy , Wound Healing , Collagen/therapeutic use , Treatment OutcomeABSTRACT
PURPOSE: Compare 12-month (12 M) safety and efficacy of endoscopic cyclophotocoagulation (ECP) + cataract surgery (Group 1) versus ECP + cataract surgery + iStent inject trabecular micro-bypass implantation (Group 2) in Brazilian patients with open-angle glaucoma (OAG). METHODS: This prospective, multicenter, comparative case series included patients with OAG and cataract who were randomized to receive treatment in Group 1 or Group 2. Outcomes included mean and percent reduction versus preoperative in intraocular pressure (IOP) and number of glaucoma medications; visual acuity; occurrence of adverse events; and rate of secondary surgeries. RESULTS: Preoperatively, Groups 1 and 2 had similar mean IOP (mean ± standard deviation 22.1 ± 3.6 and 22.0 ± 2.5 mmHg, respectively) and mean number of medications (3.3 ± 0.6 and 3.4 ± 0.6 medications, respectively). At all follow-up timepoints through 12 M, both groups achieved significant IOP and medication reductions versus preoperative (IOP p < 0.001 and number of medications p < 0.001 for both groups). At 12 M, IOP reductions were 24.2% (Group 1) and 43.6% (Group 2) (p < 0.001); mean medication reductions were 50.2% and 71.5%, respectively. Mean postoperative IOP and number of medications were higher in Group 1 than Group 2 (IOP p < 0.01 all visits, medication p < 0.01 at 6 M and 12 M). Adverse events were generally mild and infrequent in both groups. CONCLUSION: Both treatment groups (ECP + phacoemulsification, with/without iStent inject implantation) achieved significant and safe reductions in IOP and medications versus preoperative in Brazilian OAG patients. Percent reductions were significantly greater, and mean IOP and medications were significantly lower, in the group receiving iStent inject. CLINICAL TRIAL REGISTRATION (CTR): CAAE project identification #20053019.5.0000.5078. Protocol #3.587.147. Clinical Trial Database of the Federal University of Goiás, Brazil. Registration Date: September 19, 2019.
Subject(s)
Cataract , Glaucoma, Open-Angle , Glaucoma , Phacoemulsification , Humans , Glaucoma, Open-Angle/complications , Glaucoma, Open-Angle/surgery , Glaucoma, Open-Angle/drug therapy , Brazil/epidemiology , Prospective Studies , Glaucoma/surgery , Intraocular Pressure , Cataract/complicationsABSTRACT
We describe the case of a 15-year-old girl with decreased visual acuity associated with elevated intraocular pressure in both eyes and angle closure on gonioscopy. She also presented attenuation of retinal vessels and optic disc pallor with large excavation in the left eye. Ultrasound biomicroscopy revealed an anteriorly positioned ciliary body and absence of ciliary sulcus, confirming the plateau iris configuration. Spectral-domain optical coherence tomography revealed a bilateral cystoid macular edema. Genetic screening revealed heterozygous variants of the Crumbs homolog 1 (CRB1) gene (c.2843G>A and c.2506C>A). The patient underwent trabeculectomy for intraocular pressure control and topical treatment for macular edema. This case highlights the importance of performing gonioscopy and evaluating intraocular pressure in patients with a shallow anterior chamber despite young age. In addition, it also shows the importance of genetic screening, when available, in elucidating the diagnosis and providing patients and their families' information on the patient's prognosis and possible therapeutic options.
Subject(s)
Glaucoma, Angle-Closure , Retinitis Pigmentosa , Humans , Adolescent , Glaucoma, Angle-Closure/genetics , Glaucoma, Angle-Closure/surgery , Retinitis Pigmentosa/complications , Retinitis Pigmentosa/genetics , Eye Proteins/genetics , Membrane Proteins , Nerve Tissue ProteinsABSTRACT
We report the case of a 39-year-old male patient who presented with visual loss in the right eye for 6 weeks. The best-corrected visual acuity was counting fingers in the right eye and 20/30 in the left eye. The fundus examination demonstrated a right retinal detachment inferiorly extending to the fovea and a left macular serous detachment. After multimodal imaging study, the patient was diagnosed as having a bullous variant of central serous chorioretinopathy and treated with oral spironolactone associated with adjuvant laser photocoagulation. The retinal changes resolved after 6 months. The final visual acuity was 20/20 in both eyes.
ABSTRACT
ABSTRACT Objective Investigate the prevalence of postural changes and correlate them with body weight and the weight of schoolchildren's backpacks in a school in the city of São João del-Rei-MG. Material and Methods The study is an original type, with a cross-sectional design, where 109 schoolchildren of both sexes and mean age of 13 years were evaluated. The New York scale was used for posture analysis, measuring body weight, height, backpack weight, and Body Mass Index (BMI). The ANOVA statistical test and Pearson's correlation test were used, considering a significance level of 0.05. Results According to the results, the general average of the scores of postural problems was 68.7 points, with a predominance in the head, spine, hips, trunk, and abdomen. The regions of shoulder, feet, and neck presented mean scores below seven. The mean height was 1.61 m, body weight 56.03 kg, backpack weight 4.49 kg and BMI was 21.51 kg/m. Conclusion Postural alterations are highly prevalent among the evaluated students. The most affected body segments are the head, spine, hips, trunk, and abdomen. However, this finding was not related to the weight of the backpacks or the students' body weight. However, different parameters must be used to analyze the factors that may be related to such findings, such as ergonomic changes, inadequate habits, growth spurt, among others. Evidence Level III,Cross-sectional Observational Study.
RESUMO Objetivo Investigar a prevalência de alterações posturais e correlacionar com o peso corporal e o peso das mochilas dos escolares em uma escola no município de São João del-Rei-MG. Métodos O estudo é do tipo original, com delineamento transversal onde foram avaliados 109 escolares, com média de idade de 13 anos, de ambos os sexos. A escala de Nova Iorque foi utilizada para análise de postura, medição do peso corporal, altura, peso da mochila e Índice de Massa Corporal (IMC). Foi utilizado o teste estatístico ANOVA e o teste de correlação de Pearson, considerando o nível de significância de 0,05. Resultados De acordo com os resultados, a média geral dos escores dos problemas posturais foi de 68,7 pontos, com predomínio na região da cabeça, coluna, nos quadris, no tronco, e no abdômen. As regiões dos ombros, pés e pescoço apresentaram médias de escores menores que 7. A média da altura foi de 1,61m, do peso corporal de 56,03kg, do peso das mochilas de 4,49 kg e 21,51 kg/m do IMC. Conclusão Conclui-se que existe uma alta prevalência de alterações posturais entre os escolares avaliados. Sendo que, os segmentos corporais mais comprometidos são, a cabeça, a coluna vertebral, os quadris, o tronco e o abdômen. No entanto, esse achado não foi relacionado ao peso das mochilas ou ao peso corporal dos escolares. Assim, diferentes parâmetros devem ser utilizados para analisar os fatores que podem estar relacionados a tais achados, como alterações ergonômicas, hábitos inadequados, estirão de crescimento, entre outros. Nível de Evidência III, Estudo Transversal Observacional.
ABSTRACT
Resumen: Introducción: En el siglo XX el parto pasó de ser atendido en casa al ámbito hospitalario. Se adoptaron de forma acrítica intervenciones inapropiadas e innecesarias que condujeron a una deshumanización del parto. Este es el modelo que existe actualmente en la mayoría de los hospitales españoles y que fue cuestionado por la OMS ya en 1996. Objetivo: Describir las diferencias que existen en los resultados obstétricos y neonatales en primíparas en dos modelos distintos de asistencia al parto (biomédico y humanizado). Método: Se llevó a cabo un estudio descriptivo, de corte transversal. Se obtuvo una muestra por conveniencia de 205 primíparas, 110 del modelo biomédico y 95 del humanizado. Se compararon los resultados obstétricos y neonatales en dos hospitales con modelos diferentes de asistencia al parto en España. Resultados: En el modelo humanizado de asistencia al parto se obtuvieron unos mejores resultados obstétricos (inicio espontáneo, parto eutócico, periné íntegro o desgarro de I grado y menos episiotomías) que en el biomédico. No hubo diferencias en los resultados neonatales. Conclusión: Los beneficios de instaurar un modelo humanizado de asistencia al parto deberían ser considerados por los responsables de políticas sanitarias y reflejados en la mujer y su criatura.
Resumo: Introdução: No século XX, o parto deixou de ser realizado em casa para ser realizado no ambiente hospitalar. Intervenções inadequadas e desnecessárias foram adotadas acriticamente, levando a uma desumanização do parto. Este é o modelo que existe atualmente na maioria dos hospitais espanhóis e que foi questionado pela Organização Mundial da Saúde já em 1996. Objetivo: O objetivo principal desse estudo é descrever as diferenças existentes nos resultados obstétricos e neonatais em primíparas em dois modelos distintos de assistência ao parto (biomédico e humanizado). Método: Foi realizado um estudo descritivo, transversal. Obteve-se uma amostra por conveniência de 205 primíparas, 110 do modelo biomédico e 95 do modelo humanizado. Os resultados obstétricos e neonatais foram comparados em dois hospitais com diferentes modelos de assistência ao parto na Espanha. Resultados: No modelo humanizado de assistência ao parto obtiveram-se melhores resultados obstétricos (início espontâneo, parto eutócico, períneo íntegro ou laceração grau I e menos episiotomias) do que no modelo biomédico. Não houve diferença nos resultados neonatais. Conclusão: Os benefícios da implementação de um modelo humanizado de assistência ao parto devem ser considerados pelos formuladores de políticas de saúde e refletidos na mulher e em seu bebê.
Abstract: Introduction: In the 20th century, childbirth went from being attended at home to the hospital setting. Inappropriate and unnecessary interventions were uncritically adopted, leading to a dehumanization of childbirth. This is the model that currently exists in most Spanish hospitals, which has been questioned by the World Health Organization as early as 1996. Objective: The aim is to describe the differences in obstetrical and neonatal results across two different models of maternity care (biomedical model and humanised birth). Method: A correlational descriptive and multicenter study was carried out. A convenience sample of 205 primiparous women, 110 biomedical model and 95 humanised model, were recruited. Obstetrical and neonatal results were compared in two hospitals with different models of maternity care in Spain. Results: The humanised model of maternity care produces better obstetrical outcomes (spontaneous beginning of labour, normal vaginal birth, intact perineum and I degree tear and less episiotomies) than the biomedical model. There were no differences in neonatal outcomes. Conclusion: The benefits of implementing a humanised model of delivery care should be considered by health policy makers and reflected in the woman and her baby.
ABSTRACT
Electrospinning technology was used to produced polyvinylpyrrolidone (PVP)-copper salt composites with structural differences, and their virucidal activity against coronavirus was investigated. The solutions were prepared with 20, 13.3, 10, and 6.6% w/v PVP containing 3, 1.0, 0.6, and 0.2% w/v Cu (II), respectively. The rheological properties and electrical conductivity contributing to the formation of the morphologies of the composite materials were observed by scanning electron microscopy (SEM). SEM images revealed the formation of electrospun PVP-copper salt ultrafine composite fibers (0.80 ± 0.35 µm) and electrosprayed PVP-copper salt composite microparticles (1.50 ± 0.70 µm). Energy-dispersive X-ray spectroscopy (EDS) evidenced the incorporation of copper into the produced composite materials. IR spectra confirmed the chemical composition and showed an interaction of Cu (II) ions with oxygen in the PVP resonant ring. Virucidal composite fibers inactivated 99.999% of coronavirus within 5 min of contact time, with moderate cytotoxicity to L929 cells, whereas the virucidal composite microparticles presented with a virucidal efficiency of 99.999% within 1440 min of exposure, with low cytotoxicity to L929 cells (mouse fibroblast). This produced virucidal composite materials have the potential to be applied in respirators, personal protective equipment, self-cleaning surfaces, and to fabric coat personal protective equipment against SARS-CoV-2, viral outbreaks, or pandemics.
ABSTRACT
Molecularly imprinted membrane of ß-caryophyllene (MIM-ßCP) was fabricated incorporating ß-caryophyllene molecularly imprinted polymer nanoparticles (ßCP-NP) into polycaprolactone (PCL) fibers via electrospinning. The ßCP-NP were synthesized by precipitation polymerization using the ßCP as a template molecule and acrylic acid as a functional monomer in the proportion of 1:4 mol, respectively. Atomic force microscopy images and X-ray diffraction confirmed the nanoparticles' incorporation into MIM-ßCP. MIM-ßCP functionalization was evaluated by gas chromatography. The binding capacity was 1.80 ± 0.05 µmol/cm2, and the selectivity test was performed with a mixing solution of ßCP and caryophyllene oxide, as an analog compound, that extracted 77% of the ßCP in 5 min. The electrospun MIM-ßCP can be used to detect and extract the ßCP, applications in the molecular sieve, and biosensor production and may also contribute as an initial methodology to enhance versatile applications in the future, such as in the treatment of skin diseases, filters for extraction, and detection of ßCP to prevent counterfeiting of commercial products, and smart clothing with insect-repellent properties.
ABSTRACT
Aim: To identify the ideal treatment protocol and success predictors for double-session micropulse transscleral (MP3) laser for glaucoma management. Materials and methods: Patients who underwent double-session MP3, with a minimum follow-up of 6 months, were retrospectively investigated. Logistic regression analysis was used to verify preoperative success predictors. The following comparisons were made: (1) Between eyes that obtained surgical success vs failure, (2) According to the time required for MP3, and (3) Considering only eyes that required retreatment. Results: A total of 191 eyes from 148 patients were included. The preoperative intraocular pressure (IOP) was significantly higher than at last follow-up visit (27.3 ± 6.9 vs 14.6 ± 6.0 mm Hg, p < 0.001). Success was observed in 90.5% of the eyes. On logistic regression analysis with preoperative IOP and MP3 time as independent variables, only previous IOP was identified as a statistically significant factor (p = 0.004), with lower IOP relating to higher success. Eyes that required lower MP3 time underwent more MP3 procedures than those with higher MP3 time (1.2 ± 0.5 vs 1.1 ± 0.3, p = 0.03). In the 36 eyes that underwent retreatment, preoperative IOP was higher (31.6 ± 7.4 vs 26.3 ± 6.4 mm Hg, p < 0.001); eyes with successful IOP treatment had a higher MP3 treatment time at the first surgery than eyes with failed IOP correction (364.1 ± 68.2 vs 330.0 ± 18.0 seconds, p = 0.02). Conclusion: Thus, an ideal double-session MP3 protocol should use a high laser energy at the first surgery, and a high preoperative IOP can be considered as a predictor of surgical failure. Clinical significance: This is the first study to give special attention to the double-session MP3 protocol and success predictors. How to cite this article: Magacho L, Lima FE, Ávila MP. Estimating the Ideal Treatment Protocol and Success Predictors for Double-session Micropulse Transscleral Laser for Glaucoma Management. J Curr Glaucoma Pract 2022;16(2):111-116.