Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Med Sci Monit ; 30: e944310, 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38840416

ABSTRACT

Prosthodontics is a dental subspecialty that includes the preparation of dental prosthetics for missing or damaged teeth. It increasingly uses computer-assisted technologies for planning and preparing dental prosthetics. This study aims to present the findings from a systematic review of publications on artificial intelligence (AI) in prosthodontics to identify current trends and future opportunities. The review question was "What are the applications of AI in prosthodontics and how good is their performance in prosthodontics?" Electronic searching in the Web of Science, ScienceDirect, PubMed, and Cochrane Library was conducted. The search was limited to full text from January 2012 to January 2024. Quadas-2 was used for assessing quality and potential risk of bias for the selected studies. A total of 1925 studies were identified in the initial search. After removing the duplicates and applying exclusion criteria, a total of 30 studies were selected for this review. Results of the Quadas-2 assessment of included studies found that a total of 18.3% of studies were identified as low risk of bias studies, whereas 52.6% and 28.9% of included studies were identified as studies with high and unclear risk of bias, respectively. Although they are still developing, AI models have already shown promise in the areas of dental charting, tooth shade selection, automated restoration design, mapping the preparation finishing line, manufacturing casting optimization, predicting facial changes in patients wearing removable prostheses, and designing removable partial dentures.


Subject(s)
Artificial Intelligence , Prosthodontics , Artificial Intelligence/trends , Humans , Prosthodontics/methods , Prosthodontics/trends , Dental Prosthesis
2.
Medicina (Kaunas) ; 60(4)2024 Mar 31.
Article in English | MEDLINE | ID: mdl-38674234

ABSTRACT

Background and Objectives: Despite the identified benefits of early implant loading, studies have questioned its advantages compared to delayed loading in edentulous patients. This study aimed to evaluate clinical peri-implant parameters and marginal bone loss around early placed and loaded mandibular implant overdentures with a 60-month follow-up. Materials and Methods: In this prospective cohort study, 43 patients were enrolled to receive 86 early loading sub-crestal dental implants through prosthetic guides. Implant overdentures were supported by two isolated implant locator attachments between two mental foramens. Clinical peri-implant parameters, including plaque index (PI), bleeding index (BI), peri-implant pocket depth (PIPD), and marginal bone loss (MBL) were evaluated using standardized techniques at 1, 12, 24, 36, 48, and 60 months follow-up. At 60 months, complications associated with implant overdentures (IOD's) were noted. The mean comparison of peri-implant clinical parameters was performed through ANOVA test. A p-value of ≤0.05 was taken as significant. Results: Out of the total 43 enrolled patients, 8 patients were lost during follow-up; as a result, 35 patients completed the 5 years follow-up. The mean values of PI, BI, and PIPD increased with no statistical difference (p > 0.05). For marginal bone loss, an increase in the mean values was noted at different time intervals with statistical differences (p < 0.001). The most common complications noted were loosening of the abutment, occlusal adjustment, retentive locator loosening and replacement, and relining of the denture. Conclusions: Early placement of IODs failed to prevent bone loss over time and was associated with complications, predominantly consisting of abutment loosening, occlusal adjustments, broken retentive locator components, relining, and rebasing.


Subject(s)
Alveolar Bone Loss , Denture, Overlay , Mandible , Humans , Female , Male , Prospective Studies , Alveolar Bone Loss/etiology , Middle Aged , Follow-Up Studies , Mandible/surgery , Aged , Dental Prosthesis, Implant-Supported/methods , Dental Prosthesis, Implant-Supported/adverse effects , Dental Implants/adverse effects , Cohort Studies , Adult
3.
Oral Health Prev Dent ; 22: 23-30, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-38223958

ABSTRACT

PURPOSE: To evaluate the peri-implant parameters of immediately placed and loaded mandibular overdentures over a 5-year follow-up period. MATERIALS AND METHODS: All subjects who had been advised and planned for two-implant mandibular overdenture treatment were included in this study. The peri-implant parameters -including plaque index (PI), bleeding index (BI) and peri-implant pocket depth (PIPD) as well as marginal bone loss (MBL) - were assessed. In addition, prosthodontic parameters including abutment-, implant- and denture-related complications were assessed. Patients were evaluated at follow-up visits, scheduled at 1, 12, 24, 36, 48, and 60 months. The data distribution was analysed with the Shapiro-Wilk test. Data within follow-up categories were compared using ANOVA and the Tukey-Kramer test. A p-value < 0.05 was considered statistically significant. RESULTS: Among the 32 participants, 19 were males and 13 were females, with a mean age of 60.5 ± 7.33. The mean plaque index (PI), bleeding index (BI) and peri-implant pocket depth (PIPD) varied over time. However, no statistically significant difference was observed in the plaque index, bleeding index and peri-implant pocket depth over time (p > 0.05). The mean value at baseline was found to be -0.9 ± 0.3. The values increased over time, with the highest value observed at 60 months 2.6 ± 0.7, which was statistically significant (p < 0.001). CONCLUSION: Immediately placed and loaded mandibular implant overdentures using two un-splinted implants with locator attachments showed acceptable PI, BI and PIPD at the 5-year follow-up. Statistically significantly greater marginal bone loss was observed from baseline to follow-up, but it was within acceptable limits. A moderate number of restorative and abutment complications were observed during the follow-up of IODs.


Subject(s)
Alveolar Bone Loss , Dental Implants , Male , Female , Humans , Middle Aged , Aged , Follow-Up Studies , Denture, Overlay , Treatment Outcome , Alveolar Bone Loss/diagnostic imaging , Alveolar Bone Loss/etiology , Mandible
SELECTION OF CITATIONS
SEARCH DETAIL