Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 116
Filter
1.
Codas ; 36(3): e20230094, 2024.
Article in Portuguese, English | MEDLINE | ID: mdl-38896743

ABSTRACT

PURPOSE: To verify the influence of verbal intellectual-cognitive skills on speech perception in noise, in elderly with sensorineural hearing loss, considering education, age, and degree of hearing loss. METHODS: 36 elderly between 60 and 89 years old with bilateral sensorineural hearing loss participated in the study. After psychological assessment using the Wechsler Intelligence Scale for Adults (WAIS-III), they were grouped into (GI) 24 elderly without cognitive alteration and (GII) 12 elderly with risk of cognitive alteration. They underwent otorhinolaryngological assessment, audiological interview, pure tone audiometry, and assessment of speech perception in noise using the Hearing in Noise Test (HINT-Brazil). The Mann-Whitney U statistical test compared the results between the groups, and the Spearman correlation verified the variable's age, degree of hearing loss, and level of education. RESULTS: There was no difference between the groups in the ability to perceive speech in noise, except in the noise on the left condition, in which GII showed better performance in HINT-Brazil. The degree of hearing loss and level of education influenced the perception of speech in noise. The level of education was correlated with the WAIS-III results. CONCLUSION: The decline in verbal intellectual-cognitive skills did not affect speech perception of noise in the elderly with hearing loss. The degree of hearing loss and level of education influenced the performance of the elderly in the speech perception test in noise. Performance in verbal cognitive skills varied according to the level of education.


OBJETIVO: Verificar a influência das habilidades intelectuais-cognitivas verbais na percepção de fala no ruído, em idosos com perda auditiva sensorioneural, considerando a escolaridade, a idade e o grau da perda auditiva. MÉTODO: Participaram 36 idosos entre 60 e 89 anos com perda auditiva sensorioneural bilateral, que após avaliação psicológica por meio do Wechsler Intelligence Scale for Adults (WAIS III), foram divididos em (GI) 24 idosos sem alteração cognitiva e (GII) 12 idosos com risco de alteração cognitiva. Foram submetidos à avaliação otorrinolaringológica, entrevista audiológica, audiometria tonal liminar e a avaliação da percepção de fala no ruído por meio do Hearing in Noise Test (HINT-Brasil). O teste estatístico U de Mann-Whitney comparou os resultados entre os grupos, e a correlação de Spearman verificou as variáveis idade, grau da perda auditiva e nível de escolaridade. RESULTADOS: Não houve diferença entre os grupos na habilidade de percepção de fala no ruído, exceto na condição ruído à esquerda, no qual o GII apresentou melhor desempenho no HINT-Brasil. O grau da perda auditiva e o nível de escolaridade influenciaram na percepção de fala no ruído. O nível de escolaridade teve correlação com os resultados do WAIS III. CONCLUSÃO: O declínio das habilidades intelectuais-cognitivas verbais não interferiu na percepção de fala no ruído nos idosos com perda auditiva. O grau da perda auditiva e o nível de escolaridade influenciaram no desempenho dos idosos no teste de percepção de fala no ruído. O desempenho nas habilidades cognitivas verbais variou com o nível de escolaridade.


Subject(s)
Hearing Loss, Sensorineural , Noise , Speech Perception , Humans , Speech Perception/physiology , Aged , Middle Aged , Female , Male , Aged, 80 and over , Hearing Loss, Sensorineural/physiopathology , Audiometry, Pure-Tone , Cognitive Dysfunction/physiopathology , Educational Status
2.
Codas ; 36(4): e20230111, 2024.
Article in English | MEDLINE | ID: mdl-38836828

ABSTRACT

PURPOSE: To analyze the effects of auditory stimulation on heart rate variability (HRV) indices in healthy individuals with normal hearing and with hearing loss, regardless of type and/or grade, by means of a systematic review. RESEARCH STRATEGIES: This is a systematic review with a meta-analysis that addresses the following question: in healthy individuals with normal hearing and/or with hearing loss, what are the effects of auditory stimulation on HRV indices in comparison to silence? We consulted the Cochrane Library, Embase, LILACS, PubMed, Web of Science, and Scopus databases and the gray literature (Google Scholar, OpenGrey, and ProQuest). SELECTION CRITERIA: There were no restrictions as to period or language of publication. DATA ANALYSIS: We identified 451 records, an additional 261 in the gray literature, and five studies in a search through the references, resulting in a total of 717 records, with 171 duplicate records. After screening the titles and abstracts of 546 studies, we excluded 490 and considered 56 studies in full to assess their eligibility. RESULTS: Nine of these studies were included in the systematic review, eight of which were suitable for the meta-analysis. CONCLUSION: It is suggested that auditory stimulation may influence the RMSSD, pNN50, SDNN, RRTri and SD2 indices of HRV in healthy adults with normal hearing.


Subject(s)
Acoustic Stimulation , Hearing Loss , Heart Rate , Humans , Heart Rate/physiology , Acoustic Stimulation/methods , Hearing Loss/physiopathology , Hearing/physiology
3.
Codas ; 36(2): e20220273, 2024.
Article in Portuguese, English | MEDLINE | ID: mdl-38477758

ABSTRACT

PURPOSE: To analyze hyperbilirubinemia as an indicator for the definition of risk protocol in newborn hearing screening (NHS) and in auditory monitoring in full-term and preterm neonates. METHODS: This is an observational, cross-sectional and retrospective study. A total of 554 children born in a public maternity hospital were included and divided into two groups: (G1) with 373 full-terms neonates; (G2) with 181 preterm neonates. Data were collected from the participant's medical records to obtain information regarding the result of the NHS, performed by recording the automated auditory brainstem response (AABR), birth conditions, clinical characteristics, interventions performed, and results of the first test of total bilirubin (TB) and indirect bilirubin (IB) as well as the peak of TB and IB. A descriptive statistical analysis of the results was performed, and the level of significance adopted was 5%. RESULTS: On the NHS test, quotes of retest referral rates were smaller in G1 when compared to G2. There was no significant difference between the groups regarding type of delivery, gender, presence of Rh and ABO incompatibility, G6PD enzyme deficiency, and performance of phototherapy. TB and IB levels at the first exam and at peak time did not differ between neonates with "pass" and "fail" results on the NHS test in both groups. CONCLUSION: Bilirubin levels in the neonatal period below the recommended values for indication of exchange transfusion are not directly related to the "fail" result on the NHS tests in term and preterm neonates.


OBJETIVO: Analisar a hiperbilirrubinemia como indicador para a realização do protocolo de risco na triagem auditiva neonatal (TAN) e no monitoramento auditivo em neonatos a termo e prematuros. MÉTODO: Trata-se de um estudo observacional, transversal e retrospectivo. Foram incluídas 554 crianças nascidas em uma maternidade pública, subdivididas em dois grupos: (G1) com 373 recém-nascidos a termo; (G2) com 181 neonatos prematuros. Os dados foram coletados nos prontuários dos participantes, a fim de se obter informações referentes ao resultado da TAN realizada por meio do registro do Potencial Evocado Auditivo de Tronco Encefálico, às condições de nascimento, características clínicas, intervenções realizadas, resultados do primeiro exame de bilirrubina total (BT) e bilirrubina indireta (BI) e do pico de BT e BI. Realizou-se análise estatística descritiva e inferencial dos dados, com adoção do nível de significância de 5%. RESULTADOS: No teste da TAN, foram observadas taxas de encaminhamento para reteste inferiores no G1 em relação ao G2. Não houve diferença entre os grupos quanto à ocorrência do tipo de parto, sexo, presença de incompatibilidade sanguínea Rh e ABO, deficiência de enzima G6PD e realização de fototerapia. Em relação aos níveis de BT e BI no primeiro exame e no momento do pico, não houve diferenças entre os neonatos com resultado "passa" e "falha" na TAN-teste nos dois grupos. CONCLUSÃO: Os níveis de bilirrubina no período neonatal abaixo dos valores recomendados para indicação de exsanguineotransfusão não estão diretamente relacionados ao resultado "falha" na TAN em neonatos a termo e prematuros.


Subject(s)
Bilirubin , Hyperbilirubinemia , Pregnancy , Child , Infant, Newborn , Humans , Female , Cross-Sectional Studies , Retrospective Studies , Hearing , Observational Studies as Topic
4.
Rev. CEFAC ; 26(1): e9223, 2024. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1529404

ABSTRACT

ABSTRACT Purpose: to critically analyze whether the legislation regarding the Personal Frequency-Modulated (FM) System device encompasses most of the students with hearing impairment to facilitate the development of skills required for communication, literacy, and learning. Methods: a legislative analysis of the norms regarding the use of the Personal Frequency-Modulated (FM) System device. Relevant legislations were searched on public databases such as the Planalto and the Ministry of Health portals. Brazilian laws, ordinances, and relevant guidelines were consulted as well. Literature Review: Ordinance n. 1,274 of June 25, 2013, the CONITEC Report on FM in 2020 and GM/MS Ordinance No. 2,465, of September 27, 2021, which regulate the Personal Modulated Frequency System device, were identified. Conclusion: the initial ordinance of 2013, which regulated the Personal Frequency-Modulated (FM) System, was revised and updated, because it did not include children under six years of age, who are in the peak phase of oral language learning.


RESUMO Objetivo: analisar criticamente se a legislação garantidora do dispositivo Sistema de Frequência Modulada Pessoal abrange a população adequada de escolares com deficiência auditiva no critério idade, de forma a favorecer o desenvolvimento das habilidades necessárias para a comunicação, a alfabetização e a aprendizagem dessas crianças. Métodos: trata-se de uma análise legislativa das normas referentes ao uso do dispositivo Sistema de Frequência Modulada Pessoal. Para a busca da legislação pertinente, foram utilizados bancos de dados públicos, tais como: o portal do Planalto e o portal do Ministério da Saúde. Foram consultadas as leis, portarias e diretrizes Brasileiras no que se refere ao uso do Dispositivo Sistema de Frequência Modulada Pessoal. Revisão da Literatura: foram identificadas na Revisão de Literatura a Portaria n. 1.274 de 25 de junho de 2013, o Relatório do CONITEC sobre o FM no ano de 2020 e a Portaria GM/MS Nº 2.465, de 27 de setembro de 2021 que regulamentam o dispositivo Sistema de Frequência Modulada Pessoal. Conclusão: é evidente que a portaria inicial de 2013, a qual regulamentava o fornecimento do Sistema FM, foi revista e atualizada, uma vez que não contemplava crianças menores de 6 anos, em fase de máxima aprendizagem da linguagem oral, pré-alfabetização e letramento, mesmo que estivessem inseridas em instituições escolares.

5.
CoDAS ; 36(1): e20220271, 2024. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1520733

ABSTRACT

RESUMO Objetivo Verificar longitudinalmente a influência dos limiares tonais auditivos obtidos com as próteses auditivas ancoradas no osso transcutâneas e percutâneas na percepção da fala em indivíduos com malformação de orelha externa e/ou média e Otite Média Crônica. Método Estudo observacional, retrospectivo, de seguimento longitudinal de 30 indivíduos usuários unilaterais de sistema Baha® transcutâneo e percutâneo, para coleta de dados secundários dos limiares tonais obtidos por meio da audiometria em campo livre e do limiar de reconhecimento de sentenças no silêncio e no ruído nas condições: sem a prótese; no momento de ativação; no primeiro mês de uso (pós 1); e no terceiro mês (pós 2). Resultados Houve diferença significante entre os limiares tonais obtidos nas frequências de 3 e 4kHz, com melhores resultados para o percutâneo em todos os momentos de avaliação. Para os dois sistemas, observou-se melhor desempenho no reconhecimento de sentenças no silêncio e ruído, com diferença significante na ativação (p<0,001), porém manteve-se estável nos demais momentos de avaliação. O sistema percutâneo mostrou melhor benefício no reconhecimento de sentenças no ruído apenas na ativação (p=0,036), quando comparado ao transcutâneo. Conclusão O sistema percutâneo possibilitou melhor audibilidade para as frequências altas; contudo, tal audibilidade não influenciou no reconhecimento de sentenças na situação de silêncio para ambos os sistemas. Para a situação de ruído, melhores respostas foram observadas no sistema percutâneo; porém, a diferença não se manteve no decorrer do tempo.


ABSTRACT Purpose Longitudinally verify the influence of auditory tonal thresholds obtained with transcutaneous and percutaneous bone-anchored hearing aids on speech perception in individuals with external and/or middle ear malformation and chronic otitis media. Methods Observational, retrospective, longitudinal follow-up study of 30 unilateral users of the transcutaneous and percutaneous Baha® system for the collection of secondary data on pure tone thresholds obtained through free field audiometry and sentence recognition threshold in silence and noise in conditions: without the prosthesis; at the time of activation; in the first month of use (post 1); and in the third month (post 2). Results There was a significant difference between pure tone thresholds obtained at frequencies of 3 and 4kHz with better results for the percutaneous technique at all evaluation moments. For both systems, better performance was observed in sentence recognition in silence and in noise, with a significant difference in activation (p<0.001), but it remained stable during the other evaluation moments. The percutaneous system showed better benefit in recognizing sentences in noise only on activation (p=0.036), when compared to the transcutaneous system. Conclusion The percutaneous system provided better audibility for high frequencies; however, such audibility did not influence sentence recognition in the silent situation for both systems. For the noise situation, better responses were observed in the percutaneous system, however, the difference was not maintained over time.

6.
Audiol., Commun. res ; 29: e2728, 2024. tab
Article in Portuguese | LILACS | ID: biblio-1533840

ABSTRACT

RESUMO Objetivo Descrever o impacto da judicialização na realização da cirurgia de implante coclear no Sistema Único de Saúde do Brasil, incluindo o serviço público e a saúde suplementar. Métodos Foi realizado um levantamento documental de acórdãos de todos os tribunais nacionais e a jurisprudência dominante, voltados à cirurgia do implante coclear no Sistema Único de Saúde, no período de 2007 a 2019, por meio da Plataforma Jusbrasil, utilizando o termo "implante coclear" para realização da busca. Também foi realizado um levantamento na plataforma DATASUS (Departamento de Informação do Sistema Único de Saúde) sobre quantos procedimentos de implante coclear unilateral e bilateral foram realizados no mesmo período. Resultados De acordo com o DATASUS, no período de 2008 a 2019 foram realizados 8.857 procedimentos de cirurgia de implante coclear pelos entes públicos ou pelas operadoras dos planos de saúde no país. Com relação à judicialização para solicitação da cirurgia do implante coclear, unilateral ou bilateral, foram encontrados 216 processos, representando 2,43% dos casos. Conclusão A judicialização da saúde, quando se considera a cirurgia do implante coclear, tem representado uma parcela mínima dos casos, o que demonstra baixo impacto no orçamento público e não tem expressiva ação na organização do Sistema Único de Saúde.


ABSTRACT Purpose To describe the impact of Judicialization on the performance of Cochlear Implant (CI) surgery in the Brazilian Unified Health System (SUS), including the public service and supplementary health. Methods A documentary survey of judgments of all National Courts and the Dominant Jurisprudence focused on CI surgery in the SUS from 2007 to 2019 was carried out through the Jusbrasil Platform using the term "cochlear implant" to carry out the search. A survey was also carried out on the DATASUS platform on how many uni and bilateral CI procedures were performed in the same period. Results According to DATASUS, from 2008 to 2019, 8,857 CI surgery procedures were performed by Public Entities or Health Plan Operators in the country. With regard to Judicialization, for requesting unilateral or bilateral CI surgery, a total of 216 processes were found, representing a total of 2.43% of Judicialization of Cochlear Implant (CI) surgery. Conclusion In view of the data, it is possible to perceive that the Judicialization of Health when we consider the CI surgery has represented a small portion of the cases, which does not demonstrate a large impact on the public budget and does not have an impact on the organization of the SUS.


Subject(s)
Humans , Unified Health System , Cochlear Implantation/legislation & jurisprudence , Cochlear Implantation/statistics & numerical data , Supplemental Health , Health's Judicialization/statistics & numerical data , Brazil
7.
CoDAS ; 36(2): e20220273, 2024. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1550215

ABSTRACT

RESUMO Objetivo Analisar a hiperbilirrubinemia como indicador para a realização do protocolo de risco na triagem auditiva neonatal (TAN) e no monitoramento auditivo em neonatos a termo e prematuros. Método Trata-se de um estudo observacional, transversal e retrospectivo. Foram incluídas 554 crianças nascidas em uma maternidade pública, subdivididas em dois grupos: (G1) com 373 recém-nascidos a termo; (G2) com 181 neonatos prematuros. Os dados foram coletados nos prontuários dos participantes, a fim de se obter informações referentes ao resultado da TAN realizada por meio do registro do Potencial Evocado Auditivo de Tronco Encefálico, às condições de nascimento, características clínicas, intervenções realizadas, resultados do primeiro exame de bilirrubina total (BT) e bilirrubina indireta (BI) e do pico de BT e BI. Realizou-se análise estatística descritiva e inferencial dos dados, com adoção do nível de significância de 5%. Resultados No teste da TAN, foram observadas taxas de encaminhamento para reteste inferiores no G1 em relação ao G2. Não houve diferença entre os grupos quanto à ocorrência do tipo de parto, sexo, presença de incompatibilidade sanguínea Rh e ABO, deficiência de enzima G6PD e realização de fototerapia. Em relação aos níveis de BT e BI no primeiro exame e no momento do pico, não houve diferenças entre os neonatos com resultado "passa" e "falha" na TAN-teste nos dois grupos. Conclusão Os níveis de bilirrubina no período neonatal abaixo dos valores recomendados para indicação de exsanguineotransfusão não estão diretamente relacionados ao resultado "falha" na TAN em neonatos a termo e prematuros.


ABSTRACT Purpose To analyze hyperbilirubinemia as an indicator for the definition of risk protocol in newborn hearing screening (NHS) and in auditory monitoring in full-term and preterm neonates. Methods This is an observational, cross-sectional and retrospective study. A total of 554 children born in a public maternity hospital were included and divided into two groups: (G1) with 373 full-terms neonates; (G2) with 181 preterm neonates. Data were collected from the participant's medical records to obtain information regarding the result of the NHS, performed by recording the automated auditory brainstem response (AABR), birth conditions, clinical characteristics, interventions performed, and results of the first test of total bilirubin (TB) and indirect bilirubin (IB) as well as the peak of TB and IB. A descriptive statistical analysis of the results was performed, and the level of significance adopted was 5%. Results On the NHS test, quotes of retest referral rates were smaller in G1 when compared to G2. There was no significant difference between the groups regarding type of delivery, gender, presence of Rh and ABO incompatibility, G6PD enzyme deficiency, and performance of phototherapy. TB and IB levels at the first exam and at peak time did not differ between neonates with "pass" and "fail" results on the NHS test in both groups. Conclusion Bilirubin levels in the neonatal period below the recommended values for indication of exchange transfusion are not directly related to the "fail" result on the NHS tests in term and preterm neonates.

8.
Auris Nasus Larynx ; 51(3): 569-574, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38129206

ABSTRACT

OBJECTIVES: (1) To calculate the sensitivity and specificity of tympanometry with a 226 Hz probe to identify middle ear condition in children; (2) To propose the intersection range of static compliance and tympanometric peak pressure values obtained in ears with and without middle ear effusion. METHODS: 224 children's ears without middle ear alteration, with a mean age of 1 year and 4 months (GI), and 56 children's ears with middle ear effusion (GII), with a mean age of two years, were analyzed. For analysis, the static compliance and tympanometric peak pressure values obtained in the tympanometry with a 226 Hz probe were considered. RESULTS: In the group with no alteration, the Mann Whitney Test showed no significant difference between the sexes for the static compliance (p = 0.085) and tympanometric peak pressure (p = 0.782). No difference was seen, either, for compliance (p = 0.079) and pressure (p = 0.678) values, according to age. When applying the optimal criterion of the ROC curve, the cutoff value obtained was ≤0.26 ml for static compliance (sensitivity= 83.9 %; specificity= 86.6 %) and ≤-56 daPa for peak pressure (sensitivity= 82.1 %; specificity= 84.8 %). When comparing the values obtained for the two groups, it is noted that the data overlap, that is, they create an inconclusive intersection range between the normal middle ear and the altered one. CONCLUSION: The tympanometry cut-off with greater sensitivity and specificity was, respectively, 83.9 and 86.6 % for static compliance and 82.1 and 84.8 % for tympanometric peak pressure. The ranges from 0.16 to 0.43 ml for static compliance and from -109 to 25 daPa for tympanometric peak pressure do not allow defining the presence or absence of alteration in the middle ear, in children aged 6 to 36 months.


Subject(s)
Acoustic Impedance Tests , Otitis Media with Effusion , Sensitivity and Specificity , Humans , Otitis Media with Effusion/physiopathology , Otitis Media with Effusion/diagnosis , Female , Male , Child, Preschool , Infant , ROC Curve , Child , Case-Control Studies , Compliance , Ear, Middle/physiopathology
9.
CoDAS ; 36(3): e20230094, 2024. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1557604

ABSTRACT

RESUMO Objetivo Verificar a influência das habilidades intelectuais-cognitivas verbais na percepção de fala no ruído, em idosos com perda auditiva sensorioneural, considerando a escolaridade, a idade e o grau da perda auditiva. Método Participaram 36 idosos entre 60 e 89 anos com perda auditiva sensorioneural bilateral, que após avaliação psicológica por meio do Wechsler Intelligence Scale for Adults (WAIS III), foram divididos em (GI) 24 idosos sem alteração cognitiva e (GII) 12 idosos com risco de alteração cognitiva. Foram submetidos à avaliação otorrinolaringológica, entrevista audiológica, audiometria tonal liminar e a avaliação da percepção de fala no ruído por meio do Hearing in Noise Test (HINT-Brasil). O teste estatístico U de Mann-Whitney comparou os resultados entre os grupos, e a correlação de Spearman verificou as variáveis idade, grau da perda auditiva e nível de escolaridade. Resultados Não houve diferença entre os grupos na habilidade de percepção de fala no ruído, exceto na condição ruído à esquerda, no qual o GII apresentou melhor desempenho no HINT-Brasil. O grau da perda auditiva e o nível de escolaridade influenciaram na percepção de fala no ruído. O nível de escolaridade teve correlação com os resultados do WAIS III. Conclusão O declínio das habilidades intelectuais-cognitivas verbais não interferiu na percepção de fala no ruído nos idosos com perda auditiva. O grau da perda auditiva e o nível de escolaridade influenciaram no desempenho dos idosos no teste de percepção de fala no ruído. O desempenho nas habilidades cognitivas verbais variou com o nível de escolaridade.


ABSTRACT Purpose To verify the influence of verbal intellectual-cognitive skills on speech perception in noise, in elderly with sensorineural hearing loss, considering education, age, and degree of hearing loss. Methods 36 elderly between 60 and 89 years old with bilateral sensorineural hearing loss participated in the study. After psychological assessment using the Wechsler Intelligence Scale for Adults (WAIS-III), they were grouped into (GI) 24 elderly without cognitive alteration and (GII) 12 elderly with risk of cognitive alteration. They underwent otorhinolaryngological assessment, audiological interview, pure tone audiometry, and assessment of speech perception in noise using the Hearing in Noise Test (HINT-Brazil). The Mann-Whitney U statistical test compared the results between the groups, and the Spearman correlation verified the variable's age, degree of hearing loss, and level of education. Results There was no difference between the groups in the ability to perceive speech in noise, except in the noise on the left condition, in which GII showed better performance in HINT-Brazil. The degree of hearing loss and level of education influenced the perception of speech in noise. The level of education was correlated with the WAIS-III results. Conclusion The decline in verbal intellectual-cognitive skills did not affect speech perception of noise in the elderly with hearing loss. The degree of hearing loss and level of education influenced the performance of the elderly in the speech perception test in noise. Performance in verbal cognitive skills varied according to the level of education.

10.
CoDAS ; 36(4): e20230111, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1557628

ABSTRACT

ABSTRACT Purpose To analyze the effects of auditory stimulation on heart rate variability (HRV) indices in healthy individuals with normal hearing and with hearing loss, regardless of type and/or grade, by means of a systematic review. Research strategies This is a systematic review with a meta-analysis that addresses the following question: in healthy individuals with normal hearing and/or with hearing loss, what are the effects of auditory stimulation on HRV indices in comparison to silence? We consulted the Cochrane Library, Embase, LILACS, PubMed, Web of Science, and Scopus databases and the gray literature (Google Scholar, OpenGrey, and ProQuest). Selection criteria There were no restrictions as to period or language of publication. Data analysis We identified 451 records, an additional 261 in the gray literature, and five studies in a search through the references, resulting in a total of 717 records, with 171 duplicate records. After screening the titles and abstracts of 546 studies, we excluded 490 and considered 56 studies in full to assess their eligibility. Results Nine of these studies were included in the systematic review, eight of which were suitable for the meta-analysis. Conclusion It is suggested that auditory stimulation may influence the RMSSD, pNN50, SDNN, RRTri and SD2 indices of HRV in healthy adults with normal hearing.

11.
Codas ; 36(1): e20220271, 2023.
Article in Portuguese, English | MEDLINE | ID: mdl-37878957

ABSTRACT

PURPOSE: Longitudinally verify the influence of auditory tonal thresholds obtained with transcutaneous and percutaneous bone-anchored hearing aids on speech perception in individuals with external and/or middle ear malformation and chronic otitis media. METHODS: Observational, retrospective, longitudinal follow-up study of 30 unilateral users of the transcutaneous and percutaneous Baha® system for the collection of secondary data on pure tone thresholds obtained through free field audiometry and sentence recognition threshold in silence and noise in conditions: without the prosthesis; at the time of activation; in the first month of use (post 1); and in the third month (post 2). RESULTS: There was a significant difference between pure tone thresholds obtained at frequencies of 3 and 4kHz with better results for the percutaneous technique at all evaluation moments. For both systems, better performance was observed in sentence recognition in silence and in noise, with a significant difference in activation (p<0.001), but it remained stable during the other evaluation moments. The percutaneous system showed better benefit in recognizing sentences in noise only on activation (p=0.036), when compared to the transcutaneous system. CONCLUSION: The percutaneous system provided better audibility for high frequencies; however, such audibility did not influence sentence recognition in the silent situation for both systems. For the noise situation, better responses were observed in the percutaneous system, however, the difference was not maintained over time.


OBJETIVO: Verificar longitudinalmente a influência dos limiares tonais auditivos obtidos com as próteses auditivas ancoradas no osso transcutâneas e percutâneas na percepção da fala em indivíduos com malformação de orelha externa e/ou média e Otite Média Crônica. MÉTODO: Estudo observacional, retrospectivo, de seguimento longitudinal de 30 indivíduos usuários unilaterais de sistema Baha® transcutâneo e percutâneo, para coleta de dados secundários dos limiares tonais obtidos por meio da audiometria em campo livre e do limiar de reconhecimento de sentenças no silêncio e no ruído nas condições: sem a prótese; no momento de ativação; no primeiro mês de uso (pós 1); e no terceiro mês (pós 2). RESULTADOS: Houve diferença significante entre os limiares tonais obtidos nas frequências de 3 e 4kHz, com melhores resultados para o percutâneo em todos os momentos de avaliação. Para os dois sistemas, observou-se melhor desempenho no reconhecimento de sentenças no silêncio e ruído, com diferença significante na ativação (p<0,001), porém manteve-se estável nos demais momentos de avaliação. O sistema percutâneo mostrou melhor benefício no reconhecimento de sentenças no ruído apenas na ativação (p=0,036), quando comparado ao transcutâneo. CONCLUSÃO: O sistema percutâneo possibilitou melhor audibilidade para as frequências altas; contudo, tal audibilidade não influenciou no reconhecimento de sentenças na situação de silêncio para ambos os sistemas. Para a situação de ruído, melhores respostas foram observadas no sistema percutâneo; porém, a diferença não se manteve no decorrer do tempo.


Subject(s)
Hearing Aids , Speech Perception , Humans , Follow-Up Studies , Retrospective Studies , Hearing , Hearing Tests , Speech Perception/physiology
12.
Codas ; 35(4): e20220149, 2023.
Article in Portuguese, English | MEDLINE | ID: mdl-37729328

ABSTRACT

PURPOSE: To evaluate the usability and satisfaction of users with the interface of the 'Agente Escuta' application, in addition to identifying problems and possibilities for improvement. METHODS: Descriptive exploratory translational study, characterized by a usability test with a quantitative and qualitative approach, subdivided into three stages: (I) prior evaluation of usability by 10 judges, including students, primary care professionals, professors and researchers in Information Technology and Speech Therapy; (II) evaluation of the application by the target audience, that is, community health agents from six municipalities in Rio Grande do Norte; (III) evaluation of the satisfaction of the agents who used the application in their work routine. The System Usability Scale and the Net Promoter Score were used, in addition to a qualitative evaluation of the opinions. RESULTS: Usability was rated as excellent by judges, regardless of category. In the evaluation by community health agents, usability was considered good and there was no effect of the city of origin. It was found that the perception of the judges and the target audience were different, with a lower score for the participants in the second stage. However, most would give positive publicity to the product. The heuristic with the highest score was ease of memorization and participants in the third stage were interested in continuing to use the tool in practice, even after the end of the study. CONCLUSION: The Agente Escuta prototype showed good usability and satisfaction and aspects that could be improved in future solutions were identified.


OBJETIVO: Avaliar a usabilidade e satisfação dos usuários com a interface do aplicativo "Agente Escuta", além de identificar problemas e possibilidades de melhorias. MÉTODO: Estudo translacional exploratório descritivo, caracterizado por um teste de usabilidade com abordagem quanti-qualitativa, subdividido em três etapas: (I) avaliação prévia da usabilidade por 10 juízes, incluindo estudantes, profissionais da atenção primária, docentes e pesquisadores em Tecnologia da Informação e Fonoaudiologia; (II) avaliação do aplicativo pelo público-alvo, agentes comunitários de saúde de seis municípios potiguares; (III) Avaliação da satisfação dos agentes que utilizaram o aplicativo na rotina de trabalho. Utilizou-se o System Usability Scale e pelo Net Promoter Score, além de uma avaliação qualitativa das opiniões. RESULTADOS: A usabilidade foi avaliada como excelente pelos juízes, independentemente da categoria. Na avaliação pelos agentes comunitários de saúde, a usabilidade foi considerada boa e não houve efeito do município de origem. Constatou-se que a percepção dos juízes e do público-alvo foram distintas, com menor escore para os participantes da segunda etapa, no entanto, a maioria dariam publicidade positiva ao produto. A heurística com maior pontuação foi a facilidade de memorização e os participantes da terceira etapa mostraram-se interessados em continuar utilizando a ferramenta na prática, mesmo após o término do estudo. CONCLUSÃO: O protótipo do Agente Escuta apresentou boa usabilidade e satisfação e foram identificados aspectos que poderão ser aprimorados em soluções futuras.


Subject(s)
Public Health , Translational Research, Biomedical , Humans , Speech Therapy , Students
13.
Int J Audiol ; 62(5): 453-461, 2023 05.
Article in English | MEDLINE | ID: mdl-35343871

ABSTRACT

OBJECTIVE: To evaluate the effectiveness of an online continuing education course on infant hearing health for primary care professionals. DESIGN: A prospective longitudinal study with interrupted time series pre-test/post-test design. The effectiveness of the online course was assessed by comparing pre- vs. post-training performance and analysing responses to evaluations of the quality of the course. STUDY SAMPLE: The sample comprised individuals enrolled between September 2018 and August 2019 in a Ministry of Health course, "Actions in primary care for the early identification of hearing impairment" offered on the AVASUS platform. RESULTS: Of the 2908 individuals registered, 1842 (63.3%) completed the course. Their ages ranged from 18 to 77 years, and 67.4% of them were females. Students and doctors were overrepresented among the enrollees. All Brazilian states were included in the sample. Comparisons of pre- and post-training performances showed a significant improvement in knowledge, and 99.3% of the participants provided positive comments regarding the quality of the course. CONCLUSIONS: The course is an effective distance learning tool on infant hearing health for primary care professionals. The online course circumvents the limitations posed by geographical barriers and also facilitates decentralisation.


Subject(s)
Education, Distance , Female , Humans , Infant , Adolescent , Young Adult , Adult , Middle Aged , Aged , Male , Prospective Studies , Longitudinal Studies , Education, Continuing , Hearing , Primary Health Care
14.
CoDAS ; 35(4): e20220149, 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1514003

ABSTRACT

RESUMO Objetivo Avaliar a usabilidade e satisfação dos usuários com a interface do aplicativo "Agente Escuta", além de identificar problemas e possibilidades de melhorias. Método Estudo translacional exploratório descritivo, caracterizado por um teste de usabilidade com abordagem quanti-qualitativa, subdividido em três etapas: (I) avaliação prévia da usabilidade por 10 juízes, incluindo estudantes, profissionais da atenção primária, docentes e pesquisadores em Tecnologia da Informação e Fonoaudiologia; (II) avaliação do aplicativo pelo público-alvo, agentes comunitários de saúde de seis municípios potiguares; (III) Avaliação da satisfação dos agentes que utilizaram o aplicativo na rotina de trabalho. Utilizou-se o System Usability Scale e pelo Net Promoter Score, além de uma avaliação qualitativa das opiniões. Resultados A usabilidade foi avaliada como excelente pelos juízes, independentemente da categoria. Na avaliação pelos agentes comunitários de saúde, a usabilidade foi considerada boa e não houve efeito do município de origem. Constatou-se que a percepção dos juízes e do público-alvo foram distintas, com menor escore para os participantes da segunda etapa, no entanto, a maioria dariam publicidade positiva ao produto. A heurística com maior pontuação foi a facilidade de memorização e os participantes da terceira etapa mostraram-se interessados em continuar utilizando a ferramenta na prática, mesmo após o término do estudo. Conclusão O protótipo do Agente Escuta apresentou boa usabilidade e satisfação e foram identificados aspectos que poderão ser aprimorados em soluções futuras.


ABSTRACT Purpose To evaluate the usability and satisfaction of users with the interface of the 'Agente Escuta' application, in addition to identifying problems and possibilities for improvement. Methods Descriptive exploratory translational study, characterized by a usability test with a quantitative and qualitative approach, subdivided into three stages: (I) prior evaluation of usability by 10 judges, including students, primary care professionals, professors and researchers in Information Technology and Speech Therapy; (II) evaluation of the application by the target audience, that is, community health agents from six municipalities in Rio Grande do Norte; (III) evaluation of the satisfaction of the agents who used the application in their work routine. The System Usability Scale and the Net Promoter Score were used, in addition to a qualitative evaluation of the opinions. Results Usability was rated as excellent by judges, regardless of category. In the evaluation by community health agents, usability was considered good and there was no effect of the city of origin. It was found that the perception of the judges and the target audience were different, with a lower score for the participants in the second stage. However, most would give positive publicity to the product. The heuristic with the highest score was ease of memorization and participants in the third stage were interested in continuing to use the tool in practice, even after the end of the study. Conclusion The Agente Escuta prototype showed good usability and satisfaction and aspects that could be improved in future solutions were identified.

15.
Rev. CEFAC ; 25(1): e8522, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1514752

ABSTRACT

ABSTRACT Purpose: to analyze the implementation and effectiveness of a hearing loss identification and intervention program in the first years of life in primary care. Methods: an experimental study carried out in two Basic Health Units. Twenty-three Community Health Workers participated, trained through an online self-instructional course from the Ministry of Health. Subsequently, they followed the hearing and language of children from zero to two years old, referring them, if necessary, to audiological evaluation. For the analysis of pre and post online course knowledge, the Wilcoxon test was applied, and to compare the performance between the participants of the two Basic Health Units, the Mann Whitney test was used, adopting p<0.05. Additionally, the qualitative perception of participating community workers, the referrals, and the result of the audiological evaluation were analyzed. Results: the online course was effective in improving the knowledge of the participants. A total of 102 children were monitored, 15 of them were referred for evaluation. From these, four underwent hearing screening and 11 underwent a complete hearing assessment, a case of conductive hearing loss being identified. Conclusion: the implementation of a program for the identification and intervention of hearing loss, in the first years of life, in primary care, permeated by community health workers, is feasible.


RESUMO Objetivo: analisar a implantação e a eficácia de um programa de identificação e intervenção da perda auditiva nos primeiros anos de vida na atenção primária. Métodos: estudo experimental realizado em duas Unidades Básicas de Saúde. Participaram 23 agentes comunitários de saúde, capacitados por meio de um curso autoinstrucional online do Ministério da Saúde. Posteriormente, acompanharam a audição e a linguagem das crianças de zero a dois anos, encaminhando-as, se necessário, para avaliação audiológica. Para análise do conhecimento pré e pós curso online foi aplicado o teste de Wilcoxon e para comparação do desempenho entre os participantes das duas Unidades Básicas de Saúde empregou-se o teste de Mann Whitney, com adoção de p<0,05. Adicionalmente, avaliou-se a percepção qualitativa dos agentes comunitários participantes, os encaminhamentos realizados e o resultado da avaliação audiológica. Resultados: o curso online foi eficaz na melhoria do conhecimento dos participantes. Totalizaram-se 102 crianças acompanhadas, 15 delas encaminhadas para avaliação. Destas, quatro realizaram triagem auditiva e 11 realizaram a avaliação auditiva completa, sendo identificado um caso de perda auditiva condutiva. Conclusão: a implantação de um programa de identificação e intervenção da perda auditiva nos primeiros anos de vida na atenção primária, permeada por agentes comunitários de saúde, mostrou-se viável.

16.
Int J Pediatr Otorhinolaryngol ; 162: 111309, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36099781

ABSTRACT

OBJECTIVES: To analyze the feasibility of using wideband absorbance to verify the patency of pressure equalizing tubes (PETs) in clinical practice and to present the response pattern of this measure for ears with patent PET. METHODS: This observational case-control type study evaluated 48 ears of 30 children with severe or profound hearing loss, aged 10-44 months, of both sexes. The subjects were subdivided into two groups: 24 ears with Sheppard type PET (experimental group - EG) and 24 ears with normal middle ear (control group - CG), paired with the EG, according to age, sex, and ear evaluated. To obtain the wideband absorbance, a Middle-Ear Power Analyzer, version 5.0 (Mimosa Acoustics), was used, and absorbance values for pure tone and chirp stimuli were analyzed. RESULTS: There was no influence of ear (right or left) on the measurements obtained. The EG showed higher absorbance values at low frequencies. Although the two stimuli made it possible to identify the difference in acoustic transfer function between the groups studied, compared to pure tone, the chirp stimulus allowed identification of differences in a higher number of frequencies. CONCLUSIONS: Ears with a patent PET present an acoustic transfer pattern that differs from that obtained for normal middle ears, with a higher absorbance at low frequencies. Both pure tone and chirp stimuli can be used to identify such differences, nevertheless, the use of chirp stimulus is recommended, since it allows differentiation over a wider frequency range.


Subject(s)
Acoustic Impedance Tests , Ear, Middle , Acoustics , Case-Control Studies , Child , Ear, Middle/diagnostic imaging , Female , Humans , Male
17.
J Am Acad Audiol ; 32(4): 254-260, 2021 04.
Article in English | MEDLINE | ID: mdl-33962478

ABSTRACT

BACKGROUND: Contralateral noise masking is an important aspect of auditory brainstem response (ABR) measurements. PURPOSE: The primary aim of this study is to determine how contralateral white noise (WN) masking influences the amplitude and the latency of V wave generated during ABR measurements, using tone burst (TB), in adult ears with normal hearing (NH). The secondary aim of this study is to ascertain the need of contralateral masking in ABR measurements with the TB stimuli using a 3A insertion earphone, and to propose the applicability of WN masking in unilateral sensorineural hearing loss (USNHL). RESEARCH DESIGN: It is a cross-sectional observational and descriptive study. STUDY SAMPLE: Experiment 1: Thirty individuals, without any otologic, psychological, or neurological dysfunction, were selected. Experiment 2: Fifteen individuals with previous audiological diagnoses of severe and profound USNHL were considered. INTERVENTION: The study involves ABR TB at specific frequencies of 0.5, 1, 2, and 4 kHz. DATA COLLECTION AND ANALYSIS: Experiment 1: The evaluation was performed at the fixed intensity of 80 dB nHL (decibel normalized hearing level) on the tested ear, followed by the application of simultaneous masking to the nontested ear, intensity ranged from 0 to 80 dB. Experiment 2: ABR threshold measurements were first performed on the ear with hearing loss (HL) at the frequencies of 1, 2, and 4 kHz. The results were subsequently confirmed using contralateral masking. RESULTS: Experiment 1: At any given frequency, there were no statistically significant differences in the amplitude and latency of V wave with increase in the intensities of WN masking. Experiment 2: Cross-hearing was observed at least once in all frequencies analyzed through the occurrence of V wave. CONCLUSION: In conclusion, the contralateral WN masking at the maximum intensity of 80 dB does not affect the amplitude and latency of V wave of the ABR TB at 1, 2, and 4 kHz. Contralateral masking for the ABR TB presented using 3A insertion earphones is necessary at 1, 2, and 4 kHz in individuals with severe or profound degrees of USNHL and at intensities of 15, 20, and 10 dB above the ABR threshold of the nontested ear.


Subject(s)
Evoked Potentials, Auditory, Brain Stem , Hearing Loss, Unilateral , Adult , Auditory Threshold , Cross-Sectional Studies , Hearing , Humans , Noise
18.
Braz. j. otorhinolaryngol. (Impr.) ; 86(1): 91-98, Jan.-Feb. 2020. tab
Article in English | LILACS | ID: biblio-1089364

ABSTRACT

Abstract Introduction The cochlear implant is an effective device for children with severe and/or profound prelingual hearing loss, since it provides considerable improvement in oral language acquisition through the auditory pathway. The use of a cochlear implant contributes to the development of auditory perception, favoring the acquisition of the linguistic processes related to communication skills, which might have a positive effect on other areas of development. Objective The aim of this study was to verify the performance of children using cochlear implants for expressive and receptive oral language. Methods This was a prospective cross-sectional study that used the following tests: Child language test in the phonology, vocabulary, fluency and pragmatics areas, and the Peabody picture vocabulary test. Thirty children participated in this study, of both genders, aged between 36 and 72 months, with severe and/or profound bilateral sensorineural hearing loss, without other impairments and users of unilateral cochlear implant with full electrode insertion for a minimum of 12 months. Results The longer duration of the cochlear implant use, the younger age at surgery and the better performance in the auditory perception of speech influenced the performance in expressive and receptive oral language. Even though when compared to the normative language acquisition process, the results showed that these children had patterns of linguistic skills that are below their chronological age; the results indicate that these children are developing expressive and receptive oral language skills, and this is the outcome that should be taken into account in this study. Conclusion The longer duration of the cochlear implant use, the younger age at surgery and the better performance in the auditory perception of speech influenced the performance in expressive and receptive oral language skills, but not in all the studied semantic categories.


Resumo Introdução O implante coclear é um tratamento eficaz para crianças com deficiência auditiva pré-lingual de grau severo e/ou profundo, uma vez que proporciona melhoria considerável na aquisição da linguagem oral por meio da via auditiva. O uso do implante coclear contribui para o desenvolvimento da percepção auditiva e favorece a aquisição dos processos linguísticos voltados à aquisição de habilidades comunicativas que poderá repercutir positivamente em outras áreas do desenvolvimento. Objetivo Verificar o desempenho de crianças usuárias de implante coclear quanto à linguagem oral expressiva e receptiva. Método Estudo prospectivo transversal onde os seguintes testes foram usados: teste de linguagem infantil nas áreas de fonologia, vocabulário, fluência e pragmática e teste de vocabulário de imagens Peabody. Participaram deste estudo 30 crianças de ambos os sexos de 36 a 72 meses, com deficiência auditiva sensorioneural de grau severo e/ou profundo bilateral, sem outros comprometimentos e usuárias de implante coclear unilateral com inserção total dos eletrodos havia, no mínimo, 12 meses. Resultados O maior tempo de uso do implante coclear, a menor idade na cirurgia e o melhor desempenho na percepção auditiva da fala influenciaram o desempenho na linguagem oral expressiva e receptiva. Embora comparativamente ao processo de aquisição normativo da linguagem os resultados encontrados tenham revelado que essas crianças demonstraram habilidades linguísticas em padrões abaixo de sua idade cronológica, os resultados apontaram que essas crianças estão em evolução da linguagem oral expressiva e receptiva, esse é o resultado que deve ser valorizado neste estudo. Conclusão O maior tempo de uso do implante coclear, a menor idade na cirurgia e o melhor desempenho na percepção auditiva da fala influenciaram o desempenho na linguagem oral expressiva e receptiva, porém não em todas as categorias semânticas estudadas.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Auditory Perception , Cochlear Implants , Hearing Loss/rehabilitation , Language , Language Development , Audiometry , Speech Perception , Time Factors , Vocabulary , Cross-Sectional Studies , Prospective Studies , Age Factors , Language Tests
19.
Codas ; 32(1): e20180280, 2020.
Article in Portuguese, English | MEDLINE | ID: mdl-31994593

ABSTRACT

PURPOSE: To describe unilateral and bilateral asymmetric sensorineural hearing loss in children and its etiological, audiological and demographic characteristics. METHODS: Retrospective cross-sectional study developed in the Seção de Implante Coclear of Hospital de Reabilitação de Anomalias Craniofaciais, through the analysis of medical records. RESULTS: Data from 1152 patients were analyzed: 424 (37%) adolescents, adults or elderly, and 728 (63%) children, of whom 691 (95%) had bilateral symmetrical hearing loss, and 37 (5%) had unilateral hearing loss (n=10) or bilateral asymmetric (n=27) sensorineural hearing loss. The mean age at diagnosis of unilateral sensorineural hearing loss was 33.58±21.69 months, and for asymmetric bilateral it was 33.12±21.69 months, with a prevalence of 1.4% and 3.7%, respectively. The highest risk indicator for hearing loss for both groups was the family history of permanent deafness, which began in childhood. The majority of the relatives of children with unilateral sensorineural hearing loss presented the highest low socioeconomic classification (50%), while children with bilateral asymmetric sensorineural hearing loss were also be subdivided into upper (37%) and lower (37%). CONCLUSION: We observed a greater occurrence of asymmetric bilateral sensorineural hearing loss compared to unilateral hearing loss, as well as the hereditary risk indicator, with a predominance of the deep ear and female preponderance in both groups. Although neonatal hearing screening provides early identification of unilateral sensorineural hearing loss, the age at the audiological diagnosis is still above the recommended level. In addition, the majority of the children's family members presented a low level of income.


OBJETIVO: Descrever a perda auditiva sensorioneural unilateral e bilateral assimétrica em crianças quanto às características etiológicas, audiológicas e demográficas. MÉTODO: Estudo retrospectivo transversal, desenvolvido na Seção de Implante Coclear do Hospital de Reabilitação de Anomalias Craniofaciais, por meio da análise de prontuários. RESULTADOS: Foram analisados os dados de 1152 pacientes, sendo 424 (37%) adolescentes, adultos ou idosos e 728 (63%) crianças, dentre as quais, 691 (95%) apresentavam perda auditiva bilateral simétrica e 37 (5%) perda auditiva sensorioneural unilateral (n=10) ou bilateral assimétrica (n=27). A idade média ao diagnóstico na perda auditiva sensorioneural unilateral foi de 33,58±21,69 meses e na bilateral assimétrica de 33,12±21,69 meses, com prevalência de 1,4% e 3,7%, respectivamente. O indicador de risco para a deficiência auditiva de maior ocorrência para ambos os grupos foi o de antecedente familiar. A maioria dos familiares das crianças com perda auditiva sensorioneural unilateral apresentaram a classificação socioeconômica baixa superior (50%), enquanto que as crianças com perda auditiva sensorioneural bilateral assimétrica se subdividiram igualmente em baixa superior (37%) e média inferior (37%). CONCLUSÃO: Houve uma maior prevalência da perda auditiva sensorioneural bilateral assimétrica em relação à unilateral, bem como do indicador de risco de hereditariedade, com predomínio do grau profundo na pior orelha e preponderância do sexo feminino, em ambos os grupos. Apesar de a triagem auditiva neonatal propiciar a identificação precoce da perda auditiva sensorioneural unilateral, a idade no diagnóstico audiológico ainda se encontra acima do recomendado. Adicionalmente, a maioria dos familiares das crianças apresentou nível de rendimento baixo.


Subject(s)
Hearing Loss, Unilateral/etiology , Adolescent , Adult , Aged , Child , Cross-Sectional Studies , Female , Hearing Loss, Bilateral/diagnosis , Hearing Loss, Bilateral/etiology , Hearing Loss, Unilateral/diagnosis , Hearing Tests , Humans , Infant, Newborn , Male , Neonatal Screening , Retrospective Studies , Risk Factors , Sex Factors , Young Adult
20.
Braz J Otorhinolaryngol ; 86(1): 91-98, 2020.
Article in English | MEDLINE | ID: mdl-30527397

ABSTRACT

INTRODUCTION: The cochlear implant is an effective device for children with severe and/or profound prelingual hearing loss, since it provides considerable improvement in oral language acquisition through the auditory pathway. The use of a cochlear implant contributes to the development of auditory perception, favoring the acquisition of the linguistic processes related to communication skills, which might have a positive effect on other areas of development. OBJECTIVE: The aim of this study was to verify the performance of children using cochlear implants for expressive and receptive oral language. METHODS: This was a prospective cross-sectional study that used the following tests: Child language test in the phonology, vocabulary, fluency and pragmatics areas, and the Peabody picture vocabulary test. Thirty children participated in this study, of both genders, aged between 36 and 72 months, with severe and/or profound bilateral sensorineural hearing loss, without other impairments and users of unilateral cochlear implant with full electrode insertion for a minimum of 12 months. RESULTS: The longer duration of the cochlear implant use, the younger age at surgery and the better performance in the auditory perception of speech influenced the performance in expressive and receptive oral language. Even though when compared to the normative language acquisition process, the results showed that these children had patterns of linguistic skills that are below their chronological age; the results indicate that these children are developing expressive and receptive oral language skills, and this is the outcome that should be taken into account in this study. CONCLUSION: The longer duration of the cochlear implant use, the younger age at surgery and the better performance in the auditory perception of speech influenced the performance in expressive and receptive oral language skills, but not in all the studied semantic categories.


Subject(s)
Auditory Perception , Cochlear Implants , Hearing Loss/rehabilitation , Language Development , Language , Age Factors , Audiometry , Child , Child, Preschool , Cross-Sectional Studies , Female , Humans , Language Tests , Male , Prospective Studies , Speech Perception , Time Factors , Vocabulary
SELECTION OF CITATIONS
SEARCH DETAIL
...