Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Structure ; 2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38889721

ABSTRACT

Protein dynamics are essential to biological function, and methods to determine such structural rearrangements constitute a frontier in structural biology. Synchrotron radiation can track real-time protein dynamics, but accessibility to dedicated high-flux single X-ray pulse time-resolved beamlines is scarce and protein targets amendable to such characterization are limited. These limitations can be alleviated by triggering the reaction by laser-induced activation of a caged compound and probing the structural dynamics by fast-readout detectors. In this work, we established time-resolved X-ray solution scattering (TR-XSS) at the CoSAXS beamline at the MAX IV Laboratory synchrotron. Laser-induced activation of caged ATP initiated phosphoryl transfer in the adenylate kinase (AdK) enzyme, and the reaction was monitored up to 50 ms with a 2-ms temporal resolution achieved by the detector readout. The time-resolved structural signal of the protein showed minimal radiation damage effects and excellent agreement to data collected by a single X-ray pulse approach.

2.
J Appl Crystallogr ; 56(Pt 4): 967-975, 2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37555219

ABSTRACT

Characterization of the mechanical response of polymers and composite materials relies heavily on the macroscopic stress-strain response in uniaxial tensile configurations. To provide representative information, the deformation process must be homogeneous within the gauge length, which is a condition that is rarely achieved due to stress concentration or inhomogeneities within the specimen. In this work, the development of a biaxial mechanical testing device at the CoSAXS beamline at MAX IV Laboratory is presented. The design facilitates simultaneous measurement of small- and wide-angle X-ray scattering (SAXS/WAXS), allowing assessment of the microstructural configuration before, after and during the continuous deformation process at multiple length scales. The construction also supports multiple deformation conditions, while guaranteeing stability even at high loads. Furthermore, the mechanical experiments can be complemented with spatially resolved mesoscopic surface deformation measurements using 3D-surface digital image correlation (DIC). Polycarbonate (PC) was used to demonstrate the varied material response to multi-axial deformation, as PC is isotropic with a high glass transition temperature (∼150°) and high strength. As a result, a clear correlation between full-field methods and the microstructural information determined from WAXS measurements is demonstrated. When a uniaxial load is applied, homogeneous strain regions could be observed extending perpendicular to the applied load. When a secondary axial load was added (biaxial mode), it was observed that high strain domains were created near the centre of the sample and at the boundaries after yield. With increased strain, the deformation in the main deformation direction also increases. Mechanical reliability was demonstrated by carrying out static loading of polyacrylonitrile-based carbon fibre (CF) bundles. As a result, the nonlinear stiffening behaviour typically observed in CFs was seen, while no evidence of the creation of new voids during loading was observed. The results support the reliability and broad applicability of the developed technique.

3.
J Synchrotron Radiat ; 27(Pt 5): 1415-1429, 2020 Sep 01.
Article in English | MEDLINE | ID: mdl-32876619

ABSTRACT

BioMAX is the first macromolecular crystallography beamline at the MAX IV Laboratory 3 GeV storage ring, which is the first operational multi-bend achromat storage ring. Due to the low-emittance storage ring, BioMAX has a parallel, high-intensity X-ray beam, even when focused down to 20 µm × 5 µm using the bendable focusing mirrors. The beam is tunable in the energy range 5-25 keV using the in-vacuum undulator and the horizontally deflecting double-crystal monochromator. BioMAX is equipped with an MD3 diffractometer, an ISARA high-capacity sample changer and an EIGER 16M hybrid pixel detector. Data collection at BioMAX is controlled using the newly developed MXCuBE3 graphical user interface, and sample tracking is handled by ISPyB. The computing infrastructure includes data storage and processing both at MAX IV and the Lund University supercomputing center LUNARC. With state-of-the-art instrumentation, a high degree of automation, a user-friendly control system interface and remote operation, BioMAX provides an excellent facility for most macromolecular crystallography experiments. Serial crystallography using either a high-viscosity extruder injector or the MD3 as a fixed-target scanner is already implemented. The serial crystallography activities at MAX IV Laboratory will be further developed at the microfocus beamline MicroMAX, when it comes into operation in 2022. MicroMAX will have a 1 µm × 1 µm beam focus and a flux up to 1015 photons s-1 with main applications in serial crystallography, room-temperature structure determinations and time-resolved experiments.

4.
J Appl Crystallogr ; 52(Pt 2): 378-386, 2019 Apr 01.
Article in English | MEDLINE | ID: mdl-30996717

ABSTRACT

The X-ray crystallography station I911-2 at MAXLab II (Lund, Sweden) has been adapted to enable difference small- and wide-angle X-ray scattering (SAXS/WAXS) data to be recorded. Modifications to the beamline included a customized flow cell, a motorized flow cell holder, a helium cone, a beam stop, a sample stage and a sample delivery system. This setup incorporated external devices such as infrared lasers, LEDs and reaction mixers to induce conformational changes in macromolecules. This platform was evaluated through proof-of-principle experiments capturing light-induced conformational changes in phytochromes. A difference WAXS signature of conformational changes in a plant aqua-porin was also demonstrated using caged calcium.

5.
J Phys Chem Lett ; 6(17): 3379-83, 2015 Sep 03.
Article in English | MEDLINE | ID: mdl-26275765

ABSTRACT

The phytochrome family of light-switchable proteins has long been studied by biochemical, spectroscopic and crystallographic means, while a direct probe for global conformational signal propagation has been lacking. Using solution X-ray scattering, we find that the photosensory cores of several bacterial phytochromes undergo similar large-scale structural changes upon red-light excitation. The data establish that phytochromes with ordinary and inverted photocycles share a structural signaling mechanism and that a particular conserved histidine, previously proposed to be involved in signal propagation, in fact tunes photoresponse.


Subject(s)
Bacteria/chemistry , Phytochrome/chemistry , Signal Transduction
6.
J Synchrotron Radiat ; 20(Pt 4): 648-53, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23765310

ABSTRACT

The macromolecular crystallography beamline I911-3, part of the Cassiopeia/I911 suite of beamlines, is based on a superconducting wiggler at the MAX II ring of the MAX IV Laboratory in Lund, Sweden. The beamline is energy-tunable within a range between 6 and 18 keV. I911-3 opened for users in 2005. In 2010-2011 the experimental station was completely rebuilt and refurbished such that it has become a state-of-the-art experimental station with better possibilities for rapid throughput, crystal screening and work with smaller samples. This paper describes the complete I911-3 beamline and how it is embedded in the Cassiopeia suite of beamlines.

7.
Phys Rev Lett ; 110(7): 074802, 2013 Feb 15.
Article in English | MEDLINE | ID: mdl-25166376

ABSTRACT

The longitudinal electron beam properties are of crucial importance for many types of frontier accelerators, from storage rings to free electron lasers and energy recovery linacs. For the online control of the machine and its stable operation, nondestructive shot by shot bunch length measurements are needed. Among the various instrumentations proposed and installed in accelerators worldwide, the ones based on the measurement of the coherent radiation power represent the simplest and the more robust tools for operational control. The major limitation of these systems is that they usually can provide only relative bunch length estimation. In this Letter we present a novel experimental methodology to self-calibrate a simple equipment based on diffraction radiation from a gap providing a measurement of the second order moment of the longitudinal distribution. We present the theoretical basis of the proposed approach and validate it through a detailed campaign of measurements.

SELECTION OF CITATIONS
SEARCH DETAIL
...