Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 276
1.
Am J Cardiol ; 220: 84-91, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38604492

Development of functional tricuspid regurgitation (TR) because of chronic mitral disease and subsequent heart failure is common. However, the effect of TR on clinical outcomes after transcatheter mitral valve replacement (TMVR) remains unclear. We aimed to evaluate the impact of baseline TR on outcomes after TMVR. This was a single-center, retrospective analysis of patients who received valve-in-valve or valve-in-ring TMVR between 2012 and 2022. Patients were categorized into none/mild TR and moderate/severe TR based on baseline echocardiography. The primary outcome was 3 years all-cause death and the secondary outcomes were in-hospital events. Of the 135 patients who underwent TMVR, 64 (47%) exhibited none/mild TR at baseline, whereas 71 (53%) demonstrated moderate/severe TR. There were no significant differences in in-hospital events between the groups. At 3 years, the moderate/severe TR group exhibited a significantly increased risk of all-cause death (adjusted hazard ratio 3.37, 95% confidence interval 1.35 to 8.41, p = 0.009). When patients with baseline moderate/severe TR were stratified by echocardiography at 30 days into improved (36%) and nonimproved (64%) TR groups, although limited by small sample size, there was no significant difference in 3-year all-cause mortality (p = 0.48). In conclusion, this study investigating the impact of baseline TR on clinical outcomes revealed that moderate/severe TR is prevalent in those who underwent TMVR and is an independent predictor of 3-year all-cause mortality. Earlier mitral valve intervention before the development of significant TR may play a pivotal role in improving outcomes after TMVR.


Echocardiography , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Tricuspid Valve Insufficiency , Humans , Male , Tricuspid Valve Insufficiency/surgery , Female , Retrospective Studies , Aged , Heart Valve Prosthesis Implantation/methods , Mitral Valve Insufficiency/surgery , Cardiac Catheterization/methods , Severity of Illness Index , Treatment Outcome , Cause of Death/trends , Postoperative Complications/epidemiology , Aged, 80 and over , Mitral Valve/surgery , Mitral Valve/diagnostic imaging
2.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Article En | MEDLINE | ID: mdl-38599690

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Stroke Volume , Treatment Outcome , Ventricular Function, Left , Cardiac Catheterization/methods
3.
Interv Cardiol Clin ; 13(2): 217-225, 2024 Apr.
Article En | MEDLINE | ID: mdl-38432764

Left ventricular outflow tract (LVOT) obstruction is a life-threatening complication of transcatheter mitral valve replacement. In-depth analysis of pre-procedural computed tomography enables accurate prediction of this risk. Several techniques for LVOT modification, including Laceration of the Anterior Mitral leaflet to Prevent Outflow ObtructioN, preemptive alcohol septal ablation, preemptive radiofrequency ablation, and Septal Scoring Along the Midline Endocardium, have been described as effective strategies to mitigate this risk. This review aims to explore the indications, procedural steps, and outcomes associated with these LVOT modification techniques.


Endocardium , Mitral Valve , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Tomography, X-Ray Computed
4.
Circ Cardiovasc Interv ; 17(5): e013898, 2024 May.
Article En | MEDLINE | ID: mdl-38533653

BACKGROUND: Acute aortic regurgitation is life-threatening with few nonsurgical options for immediate stabilization. We propose Trans-Aortic Balloon to Ease Regurgitation Applying Counter-Pulsation (TABERNACL), a simple, on-table temporary valve using commercially available equipment to temporize acute severe aortic regurgitation. METHODS: We hypothesize that an appropriately sized commercial balloon dilatation catheter-straddling the aortic annulus and connected to a counterpulsation console-can serve as a temporizing valve to restore hemodynamic stability in acute aortic regurgitation. We performed benchtop testing of valvuloplasty, angioplasty, and sizing balloons as counterpulsation balloons. TABERNACL was assessed in vivo in a porcine model of acute aortic regurgitation (n=8). We also tested a static undersized, continuously inflated transvalvular balloon as a spacer intended physically to obstruct the regurgitant orifice. RESULTS: Benchtop testing identified that Tyshak II and PTS sizing (NuMed Braun) balloon catheters performed adequately as temporary valves (ie, complete inflation and deflation with each cycle) and resisted fatigue, in contrast to others. When TABERNACL was used in the acute severe regurgitation animals, there was immediate hemodynamic improvement, with a significant 35% increase in diastolic aortic pressure by 16 mm Hg ([95% CI, 7-25] P=0.0056), 34% reduction in left ventricular end-diastolic pressure by -7 mm Hg ([95% CI, -10 to -5] P=0.0006), improvement in the aortic diastolic index by 0.28 ([95% CI, 0.18-0.39] P=0.0009), and reversal of electrocardiographic myocardial ischemia. As an alternative, static balloon inflation across the aortic valve stabilized regurgitation hemodynamics at the expense of a new aortic gradient and caused excessive ectopy from balloon movement in the left ventricular outflow tract. CONCLUSIONS: TABERNACL improves hemodynamics and reduces coronary ischemia by electrocardiography in animals with acute severe aortic regurgitation. TABERNACL valves obstruct the diastolic regurgitant orifice without systolic obstruction. This may prove a lifesaving bridge to definitive valve replacement therapy.


Aortic Valve Insufficiency , Balloon Valvuloplasty , Disease Models, Animal , Hemodynamics , Animals , Hemodynamics/drug effects , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/diagnostic imaging , Sus scrofa , Aortic Valve/physiopathology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Equipment Design , Recovery of Function , Acute Disease , Cardiac Catheters , Time Factors , Severity of Illness Index , Ventricular Function, Left/drug effects
5.
J Am Coll Cardiol ; 83(14): 1257-1272, 2024 Apr 09.
Article En | MEDLINE | ID: mdl-38471643

BACKGROUND: Left ventricular outflow tract (LVOT) obstruction is a source of morbidity in hypertrophic cardiomyopathy (HCM) and a life-threatening complication of transcatheter mitral valve replacement (TMVR) and transcatheter aortic valve replacement (TAVR). Available surgical and transcatheter approaches are limited by high surgical risk, unsuitable septal perforators, and heart block requiring permanent pacemakers. OBJECTIVES: The authors report the initial experience of a novel transcatheter electrosurgical procedure developed to mimic surgical myotomy. METHODS: We used septal scoring along midline endocardium (SESAME) to treat patients, on a compassionate basis, with symptomatic LVOT obstruction or to create space to facilitate TMVR or TAVR. RESULTS: In this single-center retrospective study between 2021 and 2023, 76 patients underwent SESAME. In total, 11 (14%) had classic HCM, and the remainder underwent SESAME to facilitate TMVR or TAVR. All had technically successful SESAME myocardial laceration. Measures to predict post-TMVR LVOT significantly improved (neo-LVOT 42 mm2 [Q1-Q3: 7-117 mm2] to 170 mm2 [Q1-Q3: 95-265 mm2]; P < 0.001; skirt-neo-LVOT 169 mm2 [Q1-Q3: 153-193 mm2] to 214 mm2 [Q1-Q3: 180-262 mm2]; P < 0.001). Among patients with HCM, SESAME significantly decreased invasive LVOT gradients (resting: 54 mm Hg [Q1-Q3: 40-70 mm Hg] to 29 mm Hg [Q1-Q3: 12-36 mm Hg]; P = 0.023; provoked 146 mm Hg [Q1-Q3: 100-180 mm Hg] to 85 mm Hg [Q1-Q3: 40-120 mm Hg]; P = 0.076). A total of 74 (97.4%) survived the procedure. Five experienced 3 of 76 (3.9%) iatrogenic ventricular septal defects that did not require repair and 3 of 76 (3.9%) ventricular free wall perforations. Neither occurred in patients treated for HCM. Permanent pacemakers were required in 4 of 76 (5.3%), including 2 after concomitant TAVR. Lacerations were stable and did not propagate after SESAME (remaining septum: 5.9 ± 3.3 mm to 6.1 ± 3.2 mm; P = 0.8). CONCLUSIONS: With further experience, SESAME may benefit patients requiring septal reduction therapy for obstructive hypertrophic cardiomyopathy as well as those with LVOT obstruction after heart valve replacement, and/or can help facilitate transcatheter valve implantation.


Cardiomyopathy, Hypertrophic , Heart Valve Prosthesis Implantation , Myotomy , Ventricular Outflow Obstruction, Left , Ventricular Outflow Obstruction , Humans , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/methods , Retrospective Studies , Cardiac Catheterization/methods , Ventricular Outflow Obstruction/etiology , Ventricular Outflow Obstruction/surgery , Treatment Outcome , Cardiomyopathy, Hypertrophic/complications , Myotomy/adverse effects
6.
JACC Cardiovasc Interv ; 17(5): 635-644, 2024 Mar 11.
Article En | MEDLINE | ID: mdl-38244000

BACKGROUND: Transcatheter closure of transcatheter heart valve (THV)-related paravalvular leak (PVL) is associated with a high failure rate with available devices due to the complex interaction of THV and aortic/mitral annulus. OBJECTIVES: This study reports on novel transcatheter techniques to treat PVL after THV. METHODS: The authors describe consecutive patients who underwent PVL closure after transcatheter aortic valve replacement (TAVR) or transcatheter mitral valve replacement (TMVR). A covered self-expanding stent (Viabahn) was deployed in the defect to create a seal between the THV and annulus. A vascular plug (Amplatzer Vascular Plug 2 [AVP2] or AVP4) was then deployed inside the covered stent to obliterate PVL. RESULTS: Eight patients with THV-related PVL were treated using this method (aortic [3 SAPIEN, 1 Evolut], mitral [2 SAPIEN-in-MAC (mitral annular calcification), 2 M3 TMVR). Various combinations of stents and plugs were used (5 mm × 2.5 cm Viabahn + 6 mm AVP4 [n = 2], 8 mm × 2.5 cm Viabahn + 10 mm AVP2 [n = 5], and 10 mm × 5.0 cm Viabahn + 12 mm AVP2 [n = 1]). All had technical success with immediate elimination of target PVL, without in-hospital complications. None had signs of postprocedure hemolysis. All patients were discharged alive (median 3.5 days [Q1-Q3: 1.0-4.8 days]). No residual PVL was seen at discharge, except for 1 patient with mild regurgitation due to another untreated PVL location. One patient died before 30 days due to complication of valve-in-MAC TMVR. In remaining patients, none had recurrence of PVL at 30 days. Symptoms decreased to NYHA functional class I/II in 6 patients. NYHA functional class III symptoms remained in 1 patient with mitral regurgitation awaiting subsequent valve replacement procedure. CONCLUSIONS: The technique of sequential deployment of a covered stent and vascular plug may effectively treat THV-related PVL.


Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Heart Valve Prosthesis/adverse effects , Prosthesis Failure , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects , Stents , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery
8.
Ann Biomed Eng ; 52(2): 425-439, 2024 Feb.
Article En | MEDLINE | ID: mdl-37922056

Patient-specific aortic geometry and its influence on the flow in the vicinity of Transcatheter Aortic Valve (TAV) has been highlighted in numerous studies using both in silico and in vitro experiments. However, there has not yet been a detailed Particle Image Velocimetry (PIV) experiment conducted to quantify the relationship between the geometry, flow downstream of TAV, and the flow in the sinus and the neo-sinus. We tested six different patient-specific aorta models with a 26-mm SAPIEN 3 valve (Edwards Lifesciences, Irvine, CA, USA) in a left heart simulator with coronary flow. Velocities in all three cusps and circulation downstream of TAV were computed to evaluate the influence of the ascending aorta curvature on the flow field. The in vitro analysis showed that the patient-specific aortic curvature had positive correlation to the circulation in the ascending aorta (p = 0.036) and circulation had negative correlation to the particle washout time in the cusps (p = 0.011). These results showed that distinct vortical flow patterns in the ascending aorta as the main jet impinges on the aortic wall causes a recirculation region that facilitates the flow back into the sinus and the neo-sinus, thus reducing the risk of flow stagnation and washout time.


Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Blood Flow Velocity , Aorta , Prosthesis Design
9.
Eur Heart J ; 44(46): 4862-4873, 2023 Dec 07.
Article En | MEDLINE | ID: mdl-37930776

BACKGROUND AND AIMS: For patients with symptomatic, severe tricuspid regurgitation (TR), early results of transcatheter tricuspid valve (TV) intervention studies have shown significant improvements in functional status and quality of life associated with right-heart reverse remodelling. Longer-term follow-up is needed to confirm sustained improvements in these outcomes. METHODS: The prospective, single-arm, multicentre TRISCEND study enrolled 176 patients to evaluate the safety and performance of transcatheter TV replacement in patients with ≥moderate, symptomatic TR despite medical therapy. Major adverse events, reduction in TR grade and haemodynamic outcomes by echocardiography, and clinical, functional, and quality-of-life parameters are reported to one year. RESULTS: Enrolled patients were 71.0% female, mean age 78.7 years, 88.0% ≥ severe TR, and 75.4% New York Heart Association classes III-IV. Tricuspid regurgitation was reduced to ≤mild in 97.6% (P < .001), with increases in stroke volume (10.5 ± 16.8 mL, P < .001) and cardiac output (0.6 ± 1.2 L/min, P < .001). New York Heart Association class I or II was achieved in 93.3% (P < .001), Kansas City Cardiomyopathy Questionnaire score increased by 25.7 points (P < .001), and six-minute walk distance increased by 56.2 m (P < .001). All-cause mortality was 9.1%, and 10.2% of patients were hospitalized for heart failure. CONCLUSIONS: In an elderly, highly comorbid population with ≥moderate TR, patients receiving transfemoral EVOQUE transcatheter TV replacement had sustained TR reduction, significant increases in stroke volume and cardiac output, and high survival and low hospitalization rates with improved clinical, functional, and quality-of-life outcomes to one year. Funded by Edwards Lifesciences, TRISCEND ClinicalTrials.gov number, NCT04221490.


Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Female , Aged , Male , Tricuspid Valve Insufficiency/epidemiology , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/methods , Prospective Studies , Quality of Life , Treatment Outcome , Cardiac Catheterization/methods , Severity of Illness Index
10.
N Engl J Med ; 389(21): 1949-1960, 2023 Nov 23.
Article En | MEDLINE | ID: mdl-37874020

BACKGROUND: A previous analysis in this trial showed that among patients with severe, symptomatic aortic stenosis who were at low surgical risk, the rate of the composite end point of death, stroke, or rehospitalization at 1 year was significantly lower with transcatheter aortic-valve replacement (TAVR) than with surgical aortic-valve replacement. Longer-term outcomes are unknown. METHODS: We randomly assigned patients with severe, symptomatic aortic stenosis and low surgical risk to undergo either TAVR or surgery. The first primary end point was a composite of death, stroke, or rehospitalization related to the valve, the procedure, or heart failure. The second primary end point was a hierarchical composite that included death, disabling stroke, nondisabling stroke, and the number of rehospitalization days, analyzed with the use of a win ratio analysis. Clinical, echocardiographic, and health-status outcomes were assessed through 5 years. RESULTS: A total of 1000 patients underwent randomization: 503 patients were assigned to undergo TAVR, and 497 to undergo surgery. A component of the first primary end point occurred in 111 of 496 patients in the TAVR group and in 117 of 454 patients in the surgery group (Kaplan-Meier estimates, 22.8% in the TAVR group and 27.2% in the surgery group; difference, -4.3 percentage points; 95% confidence interval [CI], -9.9 to 1.3; P = 0.07). The win ratio for the second primary end point was 1.17 (95% CI, 0.90 to 1.51; P = 0.25). The Kaplan-Meier estimates for the components of the first primary end point were as follows: death, 10.0% in the TAVR group and 8.2% in the surgery group; stroke, 5.8% and 6.4%, respectively; and rehospitalization, 13.7% and 17.4%. The hemodynamic performance of the valve, assessed according to the mean (±SD) valve gradient, was 12.8±6.5 mm Hg in the TAVR group and 11.7±5.6 mm Hg in the surgery group. Bioprosthetic-valve failure occurred in 3.3% of the patients in the TAVR group and in 3.8% of those in the surgery group. CONCLUSIONS: Among low-risk patients with severe, symptomatic aortic stenosis who underwent TAVR or surgery, there was no significant between-group difference in the two primary composite outcomes. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).


Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Postoperative Complications/etiology , Risk Factors , Stroke/epidemiology , Stroke/etiology , Stroke/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , Follow-Up Studies , Patient Readmission , Heart Failure/etiology
12.
Circ Cardiovasc Interv ; 16(10): e013243, 2023 10.
Article En | MEDLINE | ID: mdl-37732604

BACKGROUND: Postinfarction ventricular septal defect (VSD) is a catastrophic complication of myocardial infarction. Surgical repair still has poor outcomes. This report describes clinical outcomes after a novel hybrid transcatheter/surgical repair in patients with apical VSD. METHODS: Seven patients with postmyocardial infarction apical VSD underwent hybrid transcatheter repair via subxiphoid surgical access. A transcatheter occluder (Amplatzer Septal Occluder) with a trailing premounted suture was deployed through the right ventricular wall and through the ventricular septum into the left ventricular apex. The trailing suture was used to connect an anchor external to the right ventricular wall. Tension on the suture then collapses the right ventricular free wall against the septum and left ventricular occluder, thereby obliterating the VSD. Outcomes were compared with 9 patients who underwent surgical repair using either patch or primary suture closure. RESULTS: All patients had significant left-to-right shunt (Qp:Qs 2.5:1; interquartile range [IQR, 2.1-2.6] hybrid repair versus 2.0:1 [IQR, 2.0-2.5] surgical repair), and elevated right ventricular systolic pressure (62 [IQR, 46-71] versus 49 [IQR, 43-54] mm Hg, respectively). All had severely depressed stroke volume index (22 versus 21 mL/m2) with ≈45% in each group requiring mechanical support preprocedurally. The procedure was done 15 (IQR, 10-50) versus 24 (IQR, 10-134) days postmyocardial infarction, respectively. Both groups of patients underwent repair with technical success and without intraprocedural death. One patient in the hybrid group and 4 in the surgical group developed multiorgan failure. The hybrid group had a higher survival at discharge (86% versus 56%) and at 30 days (71% versus 56%), but similar at 1 year (57% versus 56%). During follow-up, 1 patient in each group required reintervention for residual VSD (hybrid: 9 months versus surgical: 5 days). CONCLUSIONS: Early intervention with a hybrid transcatheter/surgical repair may be a viable alternative to traditional surgery for postinfarction apical VSD.


Anterior Wall Myocardial Infarction , Heart Septal Defects, Ventricular , Myocardial Infarction , Septal Occluder Device , Humans , Treatment Outcome , Cardiac Catheterization , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Septal Defects, Ventricular/etiology , Heart Septal Defects, Ventricular/surgery , Myocardial Infarction/complications , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/therapy
13.
J Cardiovasc Electrophysiol ; 34(11): 2225-2232, 2023 Nov.
Article En | MEDLINE | ID: mdl-37702135

INTRODUCTION: The need for pacemaker is a common complication after transcatheter aortic valve replacement (TAVR). We previously described the Emory Risk Score (ERS) to predict the need for new pacemaker implant (PPM) after TAVR. Metrics included in the score are a history of syncope, pre-existing RBBB, QRS duration ≥140 ms, and prosthesis oversizing ≥16%. To prospectively validate the previously described risk score. METHODS: We prospectively evaluated all patients without pre-existing pacemakers, ICD, or pre-existing indications for pacing undergoing TAVR with the Edwards SAPIEN 3 prosthesis at our institution from March 2019 to December 2020 (n = 661). Patients were scored prospectively; however, results were blinded from clinical decision-making. The primary endpoint was PPM at 30 days after TAVR. Performance of the ERS was evaluated using logistic regression, a calibration curve to prior performance, and receiver operating characteristic (ROC) analysis. RESULTS: A total of 48 patients (7.3%) had PPM after TAVR. A higher ERS predicted an increased likelihood of PPM (OR 2.61, 95% CI: 2.05-3.25 per point, p < 0.001). There was good correlation between observed and expected values on the calibration curve (slope = 1.04, calibration at large = 0.001). The area under the ROC curve was 0.81 (95% CI [0.74-0.88], p < 0.001). CONCLUSIONS: The ERS prospectively predicted the need for PPM in a serial, real-world cohort of patients undergoing TAVR with a balloon-expandable prosthesis, confirming findings previously described in retrospective cohorts. Notably, the prospective performance of the score was comparable with that of the initial cohorts. The risk score could serve as a framework for preprocedural risk stratification for PPM after TAVR.


Aortic Valve Stenosis , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Retrospective Studies , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/methods , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Risk Factors , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
14.
Circ Cardiovasc Interv ; 16(9): e013123, 2023 09.
Article En | MEDLINE | ID: mdl-37577788

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) in patients with a congenital or acquired abnormality resulting in enlarged right ventricular outflow tract (RVOT) is challenging and may preclude treatment with dedicated devices. We describe a technique using a physician-modified endograft to facilitate TPVR. METHODS: Six patients underwent physician-modified endograft-facilitated TPVR for severe symptomatic pulmonary insufficiency with enlarged RVOT. The fenestration was created in a commercially available endograft before implantation, which was then deployed from the dominant branch pulmonary artery into the RVOT, with the fenestration aligned with the ostium of the nondominant pulmonary artery. A covered stent was placed through the fenestration into the nondominant branch pulmonary artery, and a transcatheter heart valve was deployed within the endograft at the level of the original pulmonary valve. RESULTS: Four patients had tetralogy of Fallot, 1 had pulmonary atresia, and 1 had rheumatic valve disease. The RVOT/main pulmonary artery was severely enlarged (diameter, 44.2 [43.5-50.6] mm). All patients had reduced right ventricular (RV) function and dilated RVs (RV end-diastolic volume, 314 [235-316] mL). Successful endograft, covered stent, and transcatheter heart valve deployment were achieved in all cases without stent/valve embolization, vascular complications, or bleeding complications. At 30 days, 1 patient had mild pulmonary insufficiency, while others had none. The RV size measured by echocardiography was significantly reduced after TPVR (RV area, 34.4 [baseline] versus 29.0 [pre-discharge] versus 25.3 [30 days] cm2; P=0.03). During median follow-up of 221.5 (range, 29-652) days, there were no deaths or need for pulmonary valve reintervention. One patient developed severe tricuspid regurgitation due to entrapment of the anterior tricuspid leaflet by the endograft. The patient underwent successful tricuspid replacement and resection of the offending endograft with preservation of the pulmonary valve prosthesis. CONCLUSIONS: Simple fenestration of an off-the-shelf endograft and associated covered stent placement through the fenestration allows TPVR for patients with dysfunctional native or patch-repaired pulmonary valves and RVOT enlargement.


Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Humans , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Cardiac Catheterization , Treatment Outcome , Heart Valve Prosthesis/adverse effects , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/surgery , Stents/adverse effects , Retrospective Studies , Prosthesis Design
16.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1741-1754, 2023 08.
Article En | MEDLINE | ID: mdl-37354176

BACKGROUND: Intramyocardial guidewire navigation is a novel technique that allows free transcatheter movement within ventricular muscle. Guidewire radial depth, between endocardial and epicardial surfaces, is ambiguous by x-ray and echocardiography. OBJECTIVES: The aim of this study was to develop a simple tool, EDEN (Electrocardiographic Radial Depth Navigation), to indicate radial depth during intramyocardial guidewire navigation. Combined with routine imaging, EDEN facilitates a new family of intramyocardial catheter procedures to slice, reshape, pace, and ablate the heart. METHODS: We mapped intramyocardial electrograms of left and right ventricular walls and septum during open- and closed-chest swine procedures (N = 53), including MIRTH (Myocardial Intramural Remodeling by Transvenous Tether) ventriculoplasty. We identified radial depth-dependent features on unipolar electrograms. We developed a machine learning-based classifier to indicate categorical position, and modeled the findings in silico to test understanding of the physiology. RESULTS: EDEN signatures distinguished 5 depth zones throughout left and right ventricular free walls and interventricular septum. Relative ST-segment elevation magnitude best discriminated position and was maximum (40.1 ± 6.5 mV) in the midmyocardium. Subendocardial positions exhibited dominant Q waves with lower-amplitude ST segments (16.8 ± 5.8 mV), whereas subepicardial positions exhibited dominant R waves with lower-amplitude ST segments (15.7 ± 4.8 mV). EDEN was unaffected by pacing-induced left bundle branch block. ST-segment elevation declined over minutes and reappeared after submillimeter guidewire manipulation. Modeling recapitulated EDEN features. The machine learning-based classifier was 97% accurate. EDEN successfully guided MIRTH ventriculoplasty. CONCLUSIONS: EDEN provides a simple and reproducible real-time reflection of categorical guidewire-tip radial depth during intramyocardial guidewire navigation. Used in tandem with x-ray, EDEN enables novel, transcatheter, intramyocardial therapies such as MIRTH, SESAME (Septal Surfing Along Midline Endocardium), and cerclage ventriculoplasty.


Electrocardiography , Myocardium , Animals , Swine , Electrocardiography/methods , Heart , Endocardium , Heart Ventricles/diagnostic imaging
17.
Methodist Debakey Cardiovasc J ; 19(3): 37-49, 2023.
Article En | MEDLINE | ID: mdl-37213881

Transcatheter mitral valve replacement (TMVR) using the SAPIEN platform has been performed in failed bioprosthetic valves (valve-in-valve), surgical annuloplasty rings (valve-in-ring), and native valves with mitral annular calcification (MAC) (valve-in-MAC). Experience over the past decade has identified important challenges and solutions to improve clinical outcomes. In this review, we discuss the indication, trend in utilization, unique challenges, procedural planning, and clinical outcomes of valve-in-valve, valve-in-ring, and valve-in-MAC TMVR.


Calcinosis , Heart Valve Diseases , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Treatment Outcome , Cardiac Catheterization/adverse effects , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/surgery , Calcinosis/diagnostic imaging , Calcinosis/etiology , Calcinosis/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery
19.
J Thorac Cardiovasc Surg ; 166(4): e130-e141, 2023 10.
Article En | MEDLINE | ID: mdl-37086238

BACKGROUND: Leaflet thrombosis after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR) may be caused by blood flow stagnation in the native and neosinus regions. To date, aortic leaflet laceration has been used to mitigate coronary obstruction following TAVR; however, its influence on the fluid mechanics of the native and neosinus regions is poorly understood. This in vitro study compared the flow velocities and flow patterns in the setting of SAVR vs TAVR with and without aortic leaflet lacerations. METHODS: Two valves, (23-mm Perimount and 26-mm SAPIEN 3; Edwards Lifesciences) were studied in a validated mock flow loop under physiologic conditions. Neosinus and native sinus fluid mechanics were quantified using particle image velocimetry in the left and noncoronary cusp, with an increasing number of aortic leaflets lacerated or removed. RESULTS: Across all conditions, SAVR had the highest average sinus and neosinus velocities, and this value was used as a reference to compare against the TAVR conditions. With an increasing number of leaflets lacerated or removed with TAVR, the average sinus and neosinus velocities increased from 25% to 70% of SAVR flow (100%). Diastolic velocities were substantially augmented by leaflet laceration. Also, the shorter frame of the SAVR led to higher flow velocities compared with the longer frame of the TAVR, even after complete leaflet removal. CONCLUSIONS: Leaflet laceration augmented TAVR native and neosinus flow fields, approaching that of SAVR. These findings may have potential clinical implications for the use of single or multiple leaflet lacerations to reduce leaflet thrombosis and thus potentially improve TAVR durability.


Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Lacerations , Thrombosis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Lacerations/complications , Lacerations/surgery , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Thrombosis/etiology , Aortic Valve Stenosis/surgery , Treatment Outcome
20.
JACC Cardiovasc Interv ; 16(4): 371-395, 2023 02 27.
Article En | MEDLINE | ID: mdl-36858658

Transcaval aortic access is a versatile electrosurgical technique for large-bore arterial access through the wall of the abdominal aorta from the adjoining inferior vena cava. Although counterintuitive, its relative safety derives from the recognition that interstitial hydraulic pressure exceeds venous pressure, so arterial bleeding harmlessly decompresses into the nearby caval venous hole. Transcaval access has been performed in thousands of patients for transcatheter aortic valve replacement and endovascular thoracic aneurysm repair and to avoid limb ischemia in percutaneous mechanical circulatory support. Transcaval access may have value compared with transaxillary or subclavian access and with surgical transcarotid access when standard transfemoral access is not optimal. The dissemination of transcaval access and closure techniques has been hampered by the unavailability of commercially marketed devices. This state-of-the-art review details exemplary transcaval technique, patient selection, computed tomographic planning, step-by-step access and closure, management of complications, and procedural troubleshooting in special situations. These contemporary best practices can help operators gain or maintain proficiency.


Aorta, Abdominal , Arteries , Humans , Treatment Outcome , Endovascular Aneurysm Repair , Patient Selection
...