Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Low Temp Phys ; 209(3-4): 464-472, 2022.
Article in English | MEDLINE | ID: mdl-36439908

ABSTRACT

We present Monte Carlo simulations of radiative transfer within the absorbers of X-ray microcalorimeters, utilizing a numerical model for the photon propagation and photon absorption process within the absorber structure. In our model, we include effects of Compton scattering off bound electrons and fluorescence. Scattered or fluorescence photons as well as Auger and photoelectrons escaping the absorber can result in partial energy depositions. By implementing a simplified description of the physical processes compared to existing comprehensive particle transport software frameworks, our model aims to provide representative results at a small computational effort. This approach makes it possible to use our model for quick assessments, parametric studies, and application in other Monte Carlo-based instrument simulators like SIXTE, a software package for X-ray astronomical instrumentation. To study the impact of the energy loss effects on the spectral response of a microcalorimeter, we apply our model to the sensors of the cryogenic X-ray spectrometer X-IFU onboard the future Athena X-ray observatory.

2.
Article in English | MEDLINE | ID: mdl-35273463

ABSTRACT

Abstract: A key requirement for the correct interpretation of high-resolution X-ray spectra is that transition energies are known with high accuracy and precision. We investigate the K-shell features of Ne , CO 2 , and SF 6 gases, by measuring their photo ion-yield spectra at the BESSY II synchrotron facility simultaneously with the 1s-np fluorescence emission of He-like ions produced in the Polar-X EBIT. Accurate ab initio calculations of transitions in these ions provide the basis of the calibration. While the CO 2 result agrees well with previous measurements, the SF 6 spectrum appears shifted by ∼ 0.5 eV, about twice the uncertainty of the earlier results. Our result for Ne shows a large departure from earlier results, but may suffer from larger systematic effects than our other measurements. The molecular spectra agree well with our results of time-dependent density functional theory. We find that the statistical uncertainty allows calibrations in the desired range of 1-10 meV, however, systematic contributions still limit the uncertainty to ∼ 40-100 meV, mainly due to the temporal stability of the monochromator energy scale. Combining our absolute calibration technique with a relative energy calibration technique such as photoelectron energy spectroscopy will be necessary to realize its full potential of achieving uncertainties as low as 1-10 meV.

3.
Phys Rev Lett ; 125(24): 243001, 2020 Dec 11.
Article in English | MEDLINE | ID: mdl-33412031

ABSTRACT

We demonstrate a widely applicable technique to absolutely calibrate the energy scale of x-ray spectra with experimentally well-known and accurately calculable transitions of highly charged ions, allowing us to measure the K-shell Rydberg spectrum of molecular O_{2} with 8 meV uncertainty. We reveal a systematic ∼450 meV shift from previous literature values, and settle an extraordinary discrepancy between astrophysical and laboratory measurements of neutral atomic oxygen, the latter being calibrated against the aforementioned O_{2} literature values. Because of the widespread use of such, now deprecated, references, our method impacts on many branches of x-ray absorption spectroscopy. Moreover, it potentially reduces absolute uncertainties there to below the meV level.

4.
Gesundheitswesen ; 78(S 01): e128-e134, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27441824

ABSTRACT

The aim of the study: was to determine how far general practice teams are prepared to relieve family caregivers of palliative patients from their caregiving burden, the support they actually offer, and where they identify needs for improvement. Method: Focus groups and interviews on the issues of identification and support of family caregivers were conducted with practice teams (general practitioners, GPs, and medical assistants, MAs) and the results qualitatively analyzed. Results: 21 participants (14 GPs, 7 MAs) from 13 practices identified burdened family caregivers, thereupon offered support and provided contact details to local consultation services. They suggested to family caregivers that they should use their social network to create room for meeting their own needs. Conclusions: Practice teams use a multitude of individualized and unsystematic approaches to support family caregivers. In further studies within the framework of this project, systematic approaches will be identified and tried out.

SELECTION OF CITATIONS
SEARCH DETAIL