Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 69
Filter
1.
J Stroke Cerebrovasc Dis ; 33(11): 107958, 2024 Aug 17.
Article in English | MEDLINE | ID: mdl-39159904

ABSTRACT

OBJECTIVE: Perioperative Large Vessel Occlusions (LVOs) occurring during and following surgery are of immense clinical importance. As such, we aim to present risk factors and test if the Society of Thoracic Surgery (STS) mortality and stroke risk scores can be used to assess operative risk. METHODS: Using data containing 7 index cardiac operations at a single tertiary referral center from 2010 to 2022, logistic and multivariate regression analysis was performed to identify factors that correlate to higher operative LVO and stroke rate. Odds ratios and confidence intervals were also obtained to test if the STS-Predicted Risk of Mortality (PROM) and -Predicted Risk of Stroke (PROS) scores were positively correlated to operative LVO and stroke rate. RESULTS: Multivariate modeling showed primary risk factors for an operative LVO were diabetes (OR: 1.727 [95 % CI: 1.060-2.815]), intracranial or extracranial carotid stenosis (OR: 3.661 [95 % CI: 2.126-6.305]), and heart failure as defined by NYHA class (Class 4, OR: 3.951 [95 % CI: 2.092-7.461]; compared to Class 1). As the STS-PROM increased, the relative rate of LVO occurrence increased (very high risk, OR: 6.576 [95 % CI: 2.92-14.812], high risk, OR: 2.667 [1.125-6.322], medium risk, OR: 2.858 [1.594-5.125]; all compared to low risk). STS-PROS quartiles showed a similar relation with LVO risk (quartile 4, OR: 7.768 [95 % CI: 2.740-22.027], quartile 3, OR: 5.249 [1.800-15.306], quartile 2, OR:2.980 [0.960-9.248]; all compared to quartile 1). CONCLUSIONS: Patients with diabetes, carotid disease and heart failure are at high risk for operative LVO. Both STS-PROM and -PROS can be useful metrics for preoperative measuring of LVO risks.

2.
Clin Neurophysiol ; 164: 40-46, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38848665

ABSTRACT

OBJECTIVE: To determine the utility of electroencephalography (EEG) in predicting postoperative delirium (POD) in patients who underwent cardiovascular surgeries with EEG monitoring. METHODS: A total of 1161 patients who underwent cardiovascular surgeries with EEG monitoring were included in the study, and their data were retrospectively reviewed. POD assessment was done utilizing Intensive Care Delirium Screening Checklist (ICDSC). Patients with a score of > 4 on ICDSC were diagnosed with POD. RESULTS: Of 1161 patients, 131 patients had EEG changes and 56 (42.74%) of 131 patients experienced POD. Of 1030 patients without EEG changes, 219 (21.26%) experienced POD. EEG showed specificity of 91.5% and negative predictive value of 78.7% in detecting POD. On multivariable analysis, EEG changes showed a strong association with POD (ORadj 1.97 CI (1.30-2.99), p = 0.001) with persistent EEG changes showing even a higher risk of developing POD (ORadj 2.65 (1.43-4.92), p = 0.002). CONCLUSION: EEG change has specificity of 91.5% emphasizing the need for its implementation as a diagnostic tool for predicting POD. Patients with POD are two times more likely to experience significant EEG changes, especially persistent EEG changes when undergoing cardiovascular surgeries. SIGNIFICANCE: Intraoperative EEG can detect POD, and EEG changes based therapeutic interventions can mitigate POD.


Subject(s)
Delirium , Electroencephalography , Humans , Male , Female , Electroencephalography/methods , Middle Aged , Aged , Retrospective Studies , Delirium/diagnosis , Delirium/physiopathology , Delirium/etiology , Postoperative Complications/diagnosis , Postoperative Complications/physiopathology , Postoperative Complications/etiology , Cardiovascular Surgical Procedures/adverse effects , Intraoperative Neurophysiological Monitoring/methods , Predictive Value of Tests , Adult
3.
Clin Neurophysiol ; 161: 69-79, 2024 May.
Article in English | MEDLINE | ID: mdl-38452426

ABSTRACT

OBJECTIVE: To evaluate the diagnostic accuracy of intraoperative neurophysiological monitoring (IONM) during endovascular treatment (EVT) of ruptured intracranial aneurysms (rIA). METHODS: IONM and clinical data from 323 patients who underwent EVT for rIA from 2014-2019 were retrospectively reviewed. Significant IONM changes and outcomes were evaluated based on visual review of data and clinical documentation. RESULTS: Of the 323 patients undergoing EVT, significant IONM changes were noted in 30 patients (9.29%) and 46 (14.24%) experienced postprocedural neurological deficits (PPND). 22 out of 30 (73.33%) patients who had significant IONM changes experienced PPND. Univariable analysis showed changes in somatosensory evoked potential (SSEP) and electroencephalogram (EEG) were associated with PPND (p-values: <0.001 and <0.001, retrospectively). Multivariable analysis showed that IONM changes were significantly associated with PPND (Odd ratio (OR) 20.18 (95%CI:7.40-55.03, p-value: <0.001)). Simultaneous changes in both IONM modalities had specificity of 98.9% (95% CI: 97.1%-99.7%). While sensitivity when either modality had a change was 47.8% (95% CI: 33.9%-62.0%) to predict PPND. CONCLUSIONS: Significant IONM changes during EVT for rIA are associated with an increased risk of PPND. SIGNIFICANCE: IONM can be used confidently as a real time neurophysiological diagnostic guide for impending neurological deficits during EVT treatment of rIA.


Subject(s)
Aneurysm, Ruptured , Brain Ischemia , Electroencephalography , Endovascular Procedures , Evoked Potentials, Somatosensory , Intracranial Aneurysm , Intraoperative Neurophysiological Monitoring , Humans , Male , Female , Middle Aged , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Aneurysm, Ruptured/surgery , Aneurysm, Ruptured/physiopathology , Intracranial Aneurysm/surgery , Intracranial Aneurysm/physiopathology , Intraoperative Neurophysiological Monitoring/methods , Brain Ischemia/diagnosis , Brain Ischemia/physiopathology , Retrospective Studies , Evoked Potentials, Somatosensory/physiology , Aged , Adult , Electroencephalography/methods
4.
J Cardiovasc Dev Dis ; 11(1)2024 Jan 17.
Article in English | MEDLINE | ID: mdl-38248897

ABSTRACT

Perioperative transient ischemic attacks (PTIAs) are associated with significantly increased rates of postoperative complications such as low cardiac output, atrial fibrillation, and significantly higher mortality in cardiac procedures. The current literature on PTIAs is sparse and understudied. Therefore, we aim to understand the effects of PTIA on hospital utilization, readmission, and morbidity. Using data on all the cardiac procedures at the University of Pittsburgh Medical Center from 2011 to 2019, fine and gray analysis was performed to identify whether PTIAs and covariables correlate with increased hospital utilization, stroke, all-cause readmission, Major Adverse Cardiac and Cerebrovascular Events (MACCE), MI, and all-cause mortality. Logistic regression for longer hospitalization showed that PTIA (HR: 2.199 [95% CI: 1.416-3.416] increased utilization rates. Fine and gray modeling indicated that PTIA (HR: 1.444 [95% CI: 1.096-1.902], p < 0.01) increased the rates of follow-up all-cause readmission. However, PTIA (HR: 1.643 [95% CI: 0.913-2.956] was not statistically significant for stroke readmission modeling. Multivariate modeling for MACCE events within 30 days of surgery (HR: 0.524 [95% CI: 0.171-1.605], p > 0.25) and anytime during the follow-up period (HR: 1.116 [95% CI: 0.825-1.509], p > 0.45) showed no significant correlation with PTIA. As a result of PTIA's significant burden on the healthcare system due to increased utilization, it is critical to better define and recognize PTIA for timely management to improve perioperative outcomes.

5.
J Neurosurg ; 140(6): 1584-1590, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38157534

ABSTRACT

OBJECTIVE: Recovery of abducens nerve palsy (ANP) after endoscopic endonasal skull base surgery (ESBS) has been shown to be potentially predicted by postoperative ophthalmological examination. Triggered electromyography (t-EMG) and free-run electromyography (f-EMG) activity provide an intraoperative assessment of abducens nerve function, but associations with long-term ANP outcomes have not been explored. The objective of this study was to describe intraoperative abducens EMG characteristics and determine whether these electrophysiological profiles are associated with immediately postoperative and long-term ANP outcomes after ESBS. METHODS: The authors conducted a 5-year (2011-2016) retrospective case-control study of patients who underwent ESBS in whom the abducens nerve was stimulated (t-EMG). Electrophysiological metrics were compared between patients with a new postoperative ANP (cases) and those without ANP (controls). Pathologies included chordoma, pituitary adenoma, meningioma, cholesterol granuloma, and chondrosarcoma. Electrophysiological data included the presence of abnormal f-EMG activity, t-EMG stimulation voltage, stimulation threshold, evoked compound muscle action potential (CMAP) amplitude, onset latency, peak latency, and CMAP duration at various stages of the dissection. Controls were selected such that pathologies were similarly distributed between cases and controls. RESULTS: Fifty-six patients were included, 26 with new postoperative ANP and 30 controls without ANP. Abnormal f-EMG activity (28.0% vs 3.3%, p = 0.02) and lack of response to stimulation (27% vs 0%, p = 0.006) were more frequent in patients with immediately postoperative ANP than in controls. Patients with immediately postoperative ANP also had a lower median CMAP amplitude (35.0 vs 71.2 µV, p = 0.02) and longer onset latency (5.2 vs 2.8 msec, p = 0.04). Comparing patients with transient versus persistent ANP on follow-up, those with persistent ANP tended to have a lower CMAP amplitude (12.8 vs 57 µV, p = 0.07) and higher likelihood of not responding to stimulation at the end of the case (45.5% vs 7.1%, p = 0.06). Abnormal f-EMG was not associated with long-term ANP outcomes. CONCLUSIONS: The presence of f-EMG activity, lack of CMAP response to stimulation, decreased CMAP amplitude, and increased CMAP onset latency were associated with immediately postoperative ANP. Long-term ANP outcomes may be associated with t-EMG parameters, including whether the nerve is able to be stimulated once identified and CMAP amplitude. Future prospective studies may be designed to standardize abducens nerve electrophysiological monitoring protocols to further refine operative and prognostic utility.


Subject(s)
Abducens Nerve Diseases , Electromyography , Postoperative Complications , Skull Base , Humans , Retrospective Studies , Male , Abducens Nerve Diseases/etiology , Abducens Nerve Diseases/physiopathology , Female , Middle Aged , Case-Control Studies , Adult , Aged , Skull Base/surgery , Postoperative Complications/etiology , Skull Base Neoplasms/surgery
6.
Global Spine J ; : 21925682231219224, 2023 Dec 04.
Article in English | MEDLINE | ID: mdl-38047537

ABSTRACT

STUDY DESIGN: Systematic Review and Meta-analysis. OBJECTIVE: The purpose of this study was to evaluate whether transcranial motor evoked potential (TcMEP) alarms can predict postoperative neurologic complications in patients undergoing cervical spine decompression surgery. METHODS: A meta-analysis of the literature was performed using PubMed, Web of Science, and Embase to retrieve published reports on intraoperative TcMEP monitoring for patients undergoing cervical spine decompression surgery. The sensitivity, specificity, and diagnostic odds ratio (DOR), of overall, reversible, and irreversible TcMEP changes for predicting postoperative neurological deficit were calculated. A subgroup analysis was performed to compare anterior vs posterior approaches. RESULTS: Nineteen studies consisting of 4608 patients were analyzed. The overall incidence of postoperative neurological deficits was 2.58% (119/4608). Overall TcMEP changes had a sensitivity of 56%, specificity of 94%, and DOR of 19.26 for predicting deficit. Reversible and irreversible changes had sensitivities of 16% and 49%, specificities of 95% and 98%, and DORs of 3.54 and 71.74, respectively. In anterior procedures, TcMEP changes had a DOR of 17.57, sensitivity of 49%, and specificity of 94%. In posterior procedures, TcMEP changes had a DOR of 21.01, sensitivity of 55%, and specificity of 94%. CONCLUSION: TcMEP monitoring has high specificity but low sensitivity for predicting postoperative neurological deficit in cervical spine decompression surgery. Patients with new postoperative neurological deficits were 19 times more likely to have experienced intraoperative TcMEP changes than those without new deficits, with irreversible TcMEP changes indicating a much higher risk of deficit than reversible TcMEP changes.

7.
Eur Spine J ; 32(10): 3321-3332, 2023 10.
Article in English | MEDLINE | ID: mdl-37626247

ABSTRACT

PURPOSE: The primary aim of this study was to evaluate whether TcMEP alarms can predict the occurrence of postoperative neurological deficit in patients undergoing lumbar spine surgery. The secondary aim was to determine whether the various types of TcMEP alarms including transient and persistent changes portend varying degrees of injury risk. METHODS: This was a systematic review and meta-analysis of the literature from PubMed, Web of Science, and Embase regarding outcomes of transcranial motor-evoked potential (TcMEP) monitoring during lumbar decompression and fusion surgery. The sensitivity, specificity, and diagnostic odds ratio (DOR) of TcMEP alarms for predicting postoperative deficit were calculated and presented with forest plots and a summary receiver operating characteristic curve. RESULTS: Eight studies were included, consisting of 4923 patients. The incidence of postoperative neurological deficit was 0.73% (36/4923). The incidence of deficits in patients with significant TcMEP changes was 11.79% (27/229), while the incidence in those without changes was 0.19% (9/4694). All TcMEP alarms had a pooled sensitivity and specificity of 63 and 95% with a DOR of 34.92 (95% CI 7.95-153.42). Transient and persistent changes had sensitivities of 29% and 47%, specificities of 96% and 98%, and DORs of 8.04 and 66.06, respectively. CONCLUSION: TcMEP monitoring has high specificity but low sensitivity for predicting postoperative neurological deficit in lumbar decompression and fusion surgery. Patients who awoke with new postoperative deficits were 35 times more likely to have experienced TcMEP changes intraoperatively, with persistent changes indicating higher risk of deficit than transient changes. LEVEL OF EVIDENCE II: Diagnostic Systematic Review.


Subject(s)
Evoked Potentials, Motor , Intraoperative Neurophysiological Monitoring , Humans , Evoked Potentials, Motor/physiology , Neurosurgical Procedures , Sensitivity and Specificity , Lumbosacral Region , Decompression
8.
J Neurosurg ; 139(3): 864-872, 2023 09 01.
Article in English | MEDLINE | ID: mdl-36840739

ABSTRACT

OBJECTIVE: A reluctance to monitor extraocular cranial nerve (EOCN) function has restricted skull base surgery worldwide. Spontaneous and triggered electromyography (EMG) monitoring can be recorded intraoperatively to identify and assess potential cranial nerve injury. Determining the conductive function of EOCNs requires the collection of clear, reliable, and repeatable compound muscle action potentials (CMAPs) secondary to stimulation. EOCN EMG needle electrodes can, although infrequently, cause ocular morbidity including hematoma, edema, and scleral laceration. The aim of this study was to ascertain if minimally invasive 7-mm superficial needle electrodes would record CMAPs as well as standard 13-mm intraorbital electrodes. METHODS: Conventionally, the authors have monitored EOCN function with intraorbital placement of paired 13-mm needle electrodes into three extraocular muscles: medial rectus, superior oblique, and lateral rectus. A prospective case-control study was performed using shorter (7-mm) needle electrodes. A single minimally invasive electrode was placed superficially near each extraocular muscle and coupled with a common reference. CMAPs were recorded from the minimally invasive electrodes and compared with CMAPs recorded from the paired intraorbital electrodes. The presence or absence of CMAPs was analyzed and compared among EMG recording techniques. RESULTS: A total of 429 CMAPs were analyzed from 71 EOCNs in 25 patients. The experimental setup yielded 167 true-positive (39%), 106 false-positive (25%), 17 false-negative (4%), and 139 true-negative (32%) responses. These values were used to calculate the sensitivity (91%), specificity (57%), positive predictive value (61%), and negative predictive value (89%). EOCN electrodes were placed in 82 total eyes in 58 patients (CMAPs were obtained in 25 patients). Twenty-six eyes showed some degree of edema, bruising, or bleeding, which was transient and self-resolving. Three eyes in different patients had complications from needle placement or extraction including conjunctival hemorrhage, periorbital ecchymosis, and corneal abrasion, ptosis, and upper eyelid edema. CONCLUSIONS: Because of artifact contamination, 106 false-positive responses (25%), and 17 false-negative responses (4%), the minimally invasive EMG technique cannot reliably record CMAP responses intraoperatively as well as the intraorbital technique. Less-invasive techniques can lead to an inaccurate EOCN assessment and potential postoperative morbidity. EOCN palsies can be debilitating and lifelong; therefore, the benefits of preserving EOCN function outweigh the potential risks of morbidity from electrode placement. EMG monitoring with intraorbital electrodes remains the most reliable method of intraoperative EOCN assessment.


Subject(s)
Cranial Nerves , Oculomotor Muscles , Humans , Electromyography/methods , Case-Control Studies , Electrodes , Oculomotor Muscles/surgery , Oculomotor Muscles/innervation , Oculomotor Muscles/physiology
9.
J Clin Neurophysiol ; 40(2): 180-186, 2023 Feb 01.
Article in English | MEDLINE | ID: mdl-34510090

ABSTRACT

INTRODUCTION: This study aimed to determine the ability of multimodality intraoperative neurophysiologic monitoring, including somatosensory evoked potentials (SSEP) and EEG, to predict perioperative clinical stroke and stroke-related mortality after open-heart surgery in high-risk patients. METHODS: The records of all consecutive patients who underwent coronary artery bypass grafting, and cardiac valve repair/replacement with high risk for stroke who underwent both SSEP and EEG recording at the University of Pittsburgh Medical Center between 2009 and 2015 were reviewed. Sensitivity and specificity of these modalities to predict in-hospital clinical strokes and stroke-related mortality were calculated. RESULTS: A total of 531 patients underwent open cardiac procedures monitored using SSEP and EEG. One hundred thirty-one patients (24.67%) experienced significant changes in either modality. Fourteen patients (2.64%) suffered clinical strokes within 24 hours after surgery, and eight patients (1.50%) died during their hospitalization. The incidence of in-hospital clinical stroke and stroke-related mortality among patients who experienced a significant change in monitoring compared with those with no significant change was 11.45% versus 1.75%. The sensitivity and specificity of significant changes in either SSEP or EEG to predict in-hospital major stroke and stroke-related mortality were 0.93 and 0.77, respectively. CONCLUSIONS: Intraoperative neurophysiologic monitoring with SSEP and EEG has high sensitivity and specificity in predicting perioperative stroke and stroke-related mortality after open cardiac procedures. These results support the benefits of multimodality neuromonitoring during cardiac surgery.


Subject(s)
Cardiac Surgical Procedures , Intraoperative Neurophysiological Monitoring , Stroke , Humans , Intraoperative Neurophysiological Monitoring/methods , Evoked Potentials, Somatosensory/physiology , Stroke/diagnosis , Stroke/etiology , Sensitivity and Specificity , Cardiac Surgical Procedures/adverse effects , Retrospective Studies
10.
J Thorac Cardiovasc Surg ; 165(6): 1971-1981.e2, 2023 06.
Article in English | MEDLINE | ID: mdl-34384591

ABSTRACT

OBJECTIVE: To evaluate the ability of intraoperative neurophysiologic monitoring (IONM) during aortic arch reconstruction with hypothermic circulatory arrest (HCA) to predict early (<48 hours) adverse neurologic events (ANE; stroke or transient ischemic attack) and operative mortality. METHODS: This was an observational study of aortic arch surgeries requiring HCA from 2010 to 2018. Patients were monitored with electroencephalogram (EEG) and somatosensory evoked potentials (SSEP). Baseline characteristics and postoperative outcomes were compared according to presence or absence of IONM changes, which were defined as any acute variation in SSEP or EEG, compared with baseline. Multivariable logistic regression analysis was used to assess the association of IONM changes with operative mortality and early ANE. RESULTS: A total of 563 patients underwent aortic arch reconstruction with HCA and IONM. Of these, 119 (21.1%) patients had an IONM change, whereas 444 (78.9%) did not. Patients with IONM changes had increased operative mortality (22.7% vs 4.3%) and increased early ANE (10.9% vs 2.9%). In multivariable analysis, SSEP changes were correlated with early ANE (odds ratio [OR], 4.68; 95% confidence interval [CI], 1.51-14.56; P = .008), whereas EEG changes were not (P = .532). Permanent SSEP changes were correlated with early ANE (OR, 4.56; 95% CI, 1.51-13.77; P = .007), whereas temperature-related SSEP changes were not (P = .997). Finally, any IONM change (either SSEP or EEG) was correlated with operative mortality (OR, 5.82; 95% CI, 2.72-12.49; P < .001). CONCLUSIONS: Abnormal IONM events during aortic arch reconstruction with HCA portend worse neurologic outcomes and operative mortality and have a negative predictive value of 97.1%. SSEP might be more sensitive than EEG for predicting early ANE, especially when SSEP changes are permanent.


Subject(s)
Intraoperative Neurophysiological Monitoring , Stroke , Humans , Aorta, Thoracic/surgery , Retrospective Studies , Stroke/etiology , Predictive Value of Tests , Perfusion/adverse effects , Cerebrovascular Circulation
11.
J Am Coll Emerg Physicians Open ; 3(4): e12760, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35865130

ABSTRACT

Objectives: There has been controversy over whether ketamine affects intracranial pressure (ICP) in children. Transcranial Doppler ultrasound (TCD) is a validated technique used to assess ICP changes noninvasively. Gosling pulsatility index (PI) directly correlates with ICP changes. The objective of this study was to quantify PI changes as a surrogate marker for ICP changes in previously healthy children receiving intravenous ketamine for procedural sedation. Methods: We performed a prospective, observational study of patients 5-18 years old who underwent sedation with intravenous ketamine as monotherapy. ICP changes were assessed by surrogate PI at baseline, immediately after ketamine administration, and every 5 minutes until completion of the procedure. The primary outcome measure was PI change after ketamine administration compared to baseline (denoted ΔPI). Results: We enrolled 15 participants. Mean age was 9.9 ± 3.4 years. Most participants underwent sedation for fracture reduction (87%). Mean initial ketamine dose was 1.4 ± 0.3 mg/kg. PI decreased at all time points after ketamine administration. Mean ΔPI at sedation onset was -0.23 (95% confidence interval [CI] = -0.30 to -0.15), at 5 minutes was -0.23 (95% CI = -0.28 to -0.18), at 10 minutes was -0.14 (95% CI = -0.21 to -0.08), at 15 minutes was -0.18 (95% CI = -0.25 to -0.12), and at 20 minutes was -0.19 (95% CI = -0.26 to -0.12). Using a clinically relevant threshold of ΔPI set at +1 (+8 cm H2O), no elevation in ICP, based on the PI surrogate marker, was demonstrated with 95% confidence at all time points after ketamine administration. Conclusions: Ketamine did not significantly increase PI, which was used as a surrogate marker for ICP in this sample of previously healthy children. This pilot study demonstrates a model for evaluating ICP changes noninvasively in the emergency department.

12.
Clin Neurophysiol ; 139: 43-48, 2022 07.
Article in English | MEDLINE | ID: mdl-35525076

ABSTRACT

OBJECTIVE: We examined significant intraoperative neurophysiologic monitoring (IONM) changes and perioperative stroke as independent risk factors of long-term cardiovascular-related mortality in patients who have undergone carotid endarterectomy (CEA). METHODS: Records of patients who underwent CEA with IONM at the University of Pittsburgh Medical Center between January 1, 2009 and December 31, 2019 were analyzed retrospectively. Cardiovascular-related mortality was compared between the significant IONM change group and no IONM change group and between the perioperative stroke group and no perioperative stroke group. RESULTS: Our final cohort consisted of 2,090 patients. Patients with significant IONM changes showed nearly twice the rate of cardiovascular-related mortality up to 10 years post-CEA (hazard ratio (HR) = 1.98; 95% confidence interval (CI) [1.20 - 3.26]). Patients with perioperative stroke were four times more likely than patients without perioperative stroke to experience cardiovascular-related mortality (HR = 4.09; 95% CI [2.13 - 7.86]). CONCLUSIONS: Among CEA patients who underwent CEA and who experienced significant IONM changes or perioperative stroke, we observed long-term increased and sustained risk of cardiovascular-related mortality. SIGNIFICANCE: Significant IONM changes are valuable in predicting the risk of long-term outcomes following CEA.


Subject(s)
Carotid Stenosis , Endarterectomy, Carotid , Intraoperative Neurophysiological Monitoring , Stroke , Carotid Stenosis/surgery , Endarterectomy, Carotid/adverse effects , Humans , Retrospective Studies , Risk Factors , Stroke/etiology , Treatment Outcome
13.
Neurodiagn J ; 62(1): 6-25, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35061974

ABSTRACT

A misconception in the field of intraoperative neurophysiological monitoring (IONM) is that continuous, multi-nerve (four-limb), interleaved somatosensory evoked potential (SSEP) stimulation, while advantageous, is not universally utilized due to variety of misunderstandings regarding this approach to SSEP stimulation. This article addresses the rationale for this misconception. We find that continuous, multi-nerve, interleaved SSEP stimulation is superior to all other stimulation paradigms in most operative scenarios, allowing the fastest acquisition of SSEPs at low stimulation repetition rates, which generate the highest amplitude cortical responses.


Subject(s)
Evoked Potentials, Somatosensory , Intraoperative Neurophysiological Monitoring , Evoked Potentials, Motor/physiology , Evoked Potentials, Somatosensory/physiology , Humans , Intraoperative Neurophysiological Monitoring/methods , Intraoperative Neurophysiological Monitoring/standards , Neurosurgical Procedures , Retrospective Studies
14.
Global Spine J ; 12(5): 1003-1011, 2022 Jun.
Article in English | MEDLINE | ID: mdl-34013769

ABSTRACT

STUDY DESIGN: Systematic review and meta-analysis. OBJECTIVES: Malposition of pedicle screws during instrumentation in the lumbar spine is associated with complications secondary to spinal cord or nerve root injury. Intraoperative triggered electromyographic monitoring (t-EMG) may be used during instrumentation for early detection of malposition. The association between lumbar pedicle screws stimulated at low EMG thresholds and postoperative neurological deficits, however, remains unknown. The purpose of this study is to assess whether a low threshold t-EMG response to lumbar pedicle screw stimulation can serve as a predictive tool for postoperative neurological deficit. METHODS: The present study is a meta-analysis of the literature from PubMed, Web of Science, and Embase identifying prospective/retrospective studies with outcomes of patients who underwent lumbar spinal fusion with t-EMG testing. RESULTS: The total study cohort consisted of 2,236 patients and the total postoperative neurological deficit rate was 3.04%. 10.78% of the patients incurred at least 1 pedicle screw that was stimulated below the respective EMG alarm threshold intraoperatively. The incidence of postoperative neurological deficits in patients with a lumbar pedicle screw stimulated below EMG alarm threshold during placement was 13.28%, while only 1.80% in the patients without. The pooled DOR was 10.14. Sensitivity was 49% while specificity was 88%. CONCLUSIONS: Electrically activated lumbar pedicle screws resulting in low t-EMG alarm thresholds are highly specific but weakly sensitive for new postoperative neurological deficits. Patients with new postoperative neurological deficits after lumbar spine surgery were 10 times more likely to have had a lumbar pedicle screw stimulated at a low EMG threshold.

15.
J Neurol Surg B Skull Base ; 82(Suppl 3): e342-e348, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34306959

ABSTRACT

Objective This study proposes to present reference parameters for trigeminal (V) and facial (VII) cranial nerves (CNs)-triggered electromyography (tEMG) during endoscopic endonasal approach (EEA) skull base surgeries to allow more precise and accurate mapping of these CNs. Study Design We retrospectively reviewed EEA procedures performed at the University of Pittsburgh Medical Center between 2009 and 2015. tEMG recorded in response to stimulation of CN V and VII was analyzed. Analysis of tEMG waveforms included latencies and amplitudes. Medical records were reviewed to determine the presence of perioperative neurologic deficits. Results A total of 28 patients were included. tEMG from 34 CNs (22 V and 12 VII) were analyzed. For CN V, the average onset latency was 2.9 ± 1.1 ms and peak-to-peak amplitude was 525 ± 436.94 µV ( n = 22). For CN VII, the average onset latency and peak-to-peak amplitude were 5.1 ± 1.43 ms and 315 ± 352.58 µV for the orbicularis oculi distribution ( n = 09), 5.9 ± 0.67 ms and 517 ± 489.07 µV on orbicularis oris ( n = 08), and 5.3 ± 0.98 ms 303.1 ± 215.3 µV on mentalis ( n = 07), respectively. Conclusion Our data support the notion that onset latency may be a feasible parameter in the differentiation between the CN V and VII during the crosstalk phenomenon in EEA surgeries but the particularities of this type of procedure should be taken into consideration. A prospective analysis with a larger data set is necessary.

16.
Spine (Phila Pa 1976) ; 46(24): E1343-E1352, 2021 Dec 15.
Article in English | MEDLINE | ID: mdl-33958542

ABSTRACT

STUDY DESIGN: This study is a meta-analysis of prospective and retrospective studies identified in PubMed, Web of Science, and Embase with outcomes of patients who received intraoperative somatosensory-evoked potential (SSEP) monitoring during lumbar spine surgery. OBJECTIVE: The objective of this study is to determine the diagnostic accuracy of intraoperative lower extremity SSEP changes for predicting postoperative neurological deficit. As a secondary analysis, we evaluated three subtypes of intraoperative SSEP changes: reversible, irreversible, and total signal loss. SUMMARY OF BACKGROUND DATA: Lumbar decompression and fusion surgery can treat lumbar spinal stenosis and spondylolisthesis but carry a risk for nerve root injury. Published neurophysiological monitoring guidelines provide no conclusive evidence for the clinical utility of intraoperative SSEP monitoring during lumbar spine surgery. METHODS: A systematic review was conducted to identify studies with outcomes of patients who underwent lumbar spine surgeries with intraoperative SSEP monitoring. The sensitivity, specificity, and diagnostic odds ratio (DOR) were calculated and presented with forest plots and a summary receiver operating characteristic curve. RESULTS: The study cohort consisted of 5607 patients. All significant intraoperative SSEP changes had a sensitivity of 44% and specificity of 97% with a DOR of 22.13 (95% CI, 11.30-43.34). Reversible and irreversible SSEP changes had sensitivities of 28% and 33% and specificities of 97% and 97%, respectively. The DORs for reversible and irreversible SSEP changes were 13.93 (95% CI, 4.60-40.44) and 57.84 (95% CI, 15.95-209.84), respectively. Total loss of SSEPs had a sensitivity of 9% and specificity of 99% with a DOR of 23.91 (95% CI, 7.18-79.65). CONCLUSION: SSEP changes during lumbar spine surgery are highly specific but moderately sensitive for new postoperative neurological deficits. Patients who had postoperative neurological deficit were 22 times more likely to have exhibited intraoperative SSEP changes.Level of Evidence: 2.


Subject(s)
Evoked Potentials, Somatosensory , Intraoperative Neurophysiological Monitoring , Humans , Monitoring, Intraoperative , Neurosurgical Procedures , Prospective Studies , Retrospective Studies
17.
World Neurosurg ; 151: e250-e256, 2021 07.
Article in English | MEDLINE | ID: mdl-33872842

ABSTRACT

OBJECTIVE: Previous studies have shown that pedicle screw stimulation thresholds ≤6-8 mA yield a high diagnostic accuracy of detecting misplaced screws. Our objective was to determine the optimal "low" stimulation threshold to predict new postoperative neurologic deficits and identify additional risk factors associated with deficits. METHODS: We included patients with complete pedicle screw stimulation testing who underwent posterior lumbar spinal fusion surgeries from 2010-2012. We calculated the diagnostic accuracy of pedicle screw responses of ≤4 mA, ≤6 mA, ≤8 mA, ≤10 mA, ≤12 mA, and ≤20 mA to predict new postoperative lower-extremity (LE) neurologic deficits. We used multivariate modeling to determine the best logistic regression model to predict LE deficits and identify additional risk factors. Statistics software packages used were Python3.8.5, NumPy 1.19.1, Pandas 1.1.1, and SPSS26. RESULTS: We studied 1179 patients who underwent 8584 pedicle screw stimulations with somatosensory evoked potential and free-run electromyographic monitoring for posterior lumbar spinal fusion. Twenty-five (2.1%) patients had new LE neurologic deficits. A stimulation threshold of ≤8 mA had a sensitivity/specificity of 32%/90% and a diagnostic odds ratio/area under the curve of 4.34 [95% confidence interval: 1.83, 10.27]/0.61 [0.49, 0.74] in predicting postoperative deficit. Multivariate analysis showed that patients who had pedicle screws with stimulation thresholds ≤8 mA are 3.15 [1.26, 7.83]× more likely to have postoperative LE deficits while patients who have undergone a revision lumbar spinal fusion surgery are 3.64 [1.38, 9.61]× more likely. CONCLUSIONS: Our results show that low thresholds are indicative of not only screw proximity to the nerve but also an increased likelihood of postoperative neurologic deficit. Thresholds ≤8 mA prove to be the optimal "low" threshold to help guide a correctly positioned pedicle screw placement and detect postoperative deficits.


Subject(s)
Lumbar Vertebrae/surgery , Pedicle Screws/adverse effects , Postoperative Complications/diagnosis , Spinal Fusion/adverse effects , Aged , Electric Stimulation/methods , Female , Humans , Male , Middle Aged , Postoperative Complications/etiology , Postoperative Period , Sensitivity and Specificity
18.
Spine J ; 21(4): 555-570, 2021 04.
Article in English | MEDLINE | ID: mdl-33460808

ABSTRACT

BACKGROUND CONTEXT: Cervical decompression and fusion surgery remains a mainstay of treatment for a variety of cervical pathologies. Potential intraoperative injury to the spinal cord and nerve roots poses nontrivial risk for consequent postoperative neurologic deficits. Although neuromonitoring with intraoperative somatosensory evoked potentials (SSEPs) is often used in cervical spine surgery, its therapeutic value remains controversial. PURPOSE: The purpose of the present study was to evaluate whether significant SSEP changes can predict postoperative neurologic complications in cervical spine surgery. A subgroup analysis was performed to compare the predictive power of SSEP changes in both anterior and posterior approaches. STUDY DESIGN: The present study was a meta-analysis of the literature from PubMed, Web of Science, and Embase to identify prospective/retrospective studies with outcomes of patients who underwent cervical spine surgeries with intraoperative SSEP monitoring. PATIENT SAMPLE: The total cohort consisted of 7,747 patients who underwent cervical spine surgery with intraoperative SSEP monitoring. METHODS: Inclusion criteria for study selection were as follows: (1) prospective or retrospective cohort studies, (2) studies conducted in patients undergoing elective cervical spine surgery not due to aneurysm, tumor, or trauma with intraoperative SSEP monitoring, (3) studies that reported postoperative neurologic outcomes, (4) studies conducted with a sample size ≥20 patients, (5) studies with only adult patients ≥18 years of age, (6) studies published in English, (7) studies inclusive of an abstract. OUTCOME MEASURES: The sensitivity, specificity, diagnostic odds ratio (DOR), and likelihood ratios of overall SSEP changes, reversible SSEP changes, irreversible SSEP changes, and SSEP loss for predicting postoperative neurological deficit were calculated. RESULTS: The total rate of postoperative neurological deficits was 2.50% (194/7,747) and the total rate of SSEP changes was 7.36% (570/7,747). The incidence of postoperative neurological deficit in patients with intraoperative SSEP changes was 16.49% (94/570) while only 1.39% (100/7,177) in patients without. All significant intraoperative SSEP changes had a sensitivity of 46.0% and specificity of 96.7% with a DOR of 27.32. Reversible and irreversible SSEP changes had sensitivities of 17.7% and 37.1% and specificities of 97.5% and 99.5%, respectively. The DORs for reversible and irreversible SSEP changes were 9.01 and 167.90, respectively. SSEP loss had a DOR of 51.39, sensitivity of 17.3% and specificity 99.6%. In anterior procedures, SSEP changes had a DOR of 9.60, sensitivity of 34.2%, and specificity of 94.7%. In posterior procedures, SSEP changes had a DOR of 13.27, sensitivity of 42.6%, and specificity of 94.0%. CONCLUSIONS: SSEP monitoring is highly specific but weakly sensitive for postoperative neurological deficit following cervical spine surgery. The analysis found that patients with new postoperative neurological deficits were nearly 27 times more likely to have had significant intraoperative SSEP change. Loss of SSEP signals and irreversible SSEP changes seem to indicate a much higher risk of injury than reversible SSEP changes.


Subject(s)
Evoked Potentials, Somatosensory , Intraoperative Neurophysiological Monitoring , Adult , Cervical Vertebrae/surgery , Evoked Potentials, Motor , Humans , Prospective Studies , Retrospective Studies
19.
World Neurosurg ; 148: e43-e57, 2021 04.
Article in English | MEDLINE | ID: mdl-33301995

ABSTRACT

OBJECTIVE: In the present study, we investigated the role of intraoperative neuromonitoring (IONM) in internal carotid artery (ICA) injury during endoscopic endonasal skull base surgery (EESBS). METHODS: The study group included all 13 patients who had experienced an ICA injury during EESBS with IONM from 2004 to 2017. The medical records were reviewed for the perioperative data. The IONM reports were reviewed to evaluate the baseline somatosensory evoked potentials (SSEP), electroencephalography (EEG), and brainstem auditory evoked potentials (BAEP) and their significant changes related to ICA injury and/or the subsequent surgical/endovascular interventions. RESULTS: All 13 patients had undergone SSEP and 7 patients had BAEP monitoring during surgery. EEG was added during emergent angiography following the surgery for 5 patients. Two patients showed significant SSEP changes, and one showed significant SSEP and EEG changes, indicating cerebral hypoperfusion. Of these 3 patients, patient 1 had experienced irreversible SSEP loss with postoperative stroke. Patients 2 and 3 had SSEP and/or EEG changes that had recovered to baseline after interventions without postoperative deficits. Despite ICA injury, 10 patients showed no significant SSEP and/or EEG changes, and all 7 patients with BAEP monitoring showed no significant BAEP changes, indicating adequate cerebral and brainstem perfusion, respectively. The injured ICA was sacrificed in 4 patients, of whom 3 showed stable SSEP and 1 had experienced irreversible SSEP loss. IONM correlated with the postoperative neurologic examination findings in all cases, adequately predicting the neurologic outcomes after ICA injury. CONCLUSION: SSEP and EEG monitoring can accurately detect cerebral hypoperfusion and provide real-time feedback during surgery. SSEP and EEG changes predicted for neurologic outcomes and guide surgical decisions regarding the preservation or sacrifice of the ICA. Comprehensive multimodality monitoring according to the surgical risks can serve to detect and guide the management of ICA injury in EESBS.


Subject(s)
Carotid Artery Injuries/diagnosis , Carotid Artery, Internal , Intraoperative Complications/diagnosis , Intraoperative Neurophysiological Monitoring/methods , Neuroendoscopy/adverse effects , Skull Base/surgery , Adult , Aged , Aged, 80 and over , Carotid Artery Injuries/etiology , Carotid Artery Injuries/physiopathology , Carotid Artery, Internal/physiopathology , Child , Electroencephalography/methods , Evoked Potentials, Auditory/physiology , Evoked Potentials, Somatosensory/physiology , Female , Humans , Intraoperative Complications/etiology , Intraoperative Complications/physiopathology , Male , Middle Aged , Nasal Cavity/surgery
20.
Spine (Phila Pa 1976) ; 46(2): E139-E145, 2021 Jan 15.
Article in English | MEDLINE | ID: mdl-33347093

ABSTRACT

STUDY DESIGN: Retrospective observational study. OBJECTIVE: It has been shown that pedicle screw stimulation thresholds less than or equal to 8 mA yield a very high diagnostic accuracy of detecting misplaced screws in spinal surgery. In our study, we determined clinical implications of low stimulation thresholds. SUMMARY OF BACKGROUND DATA: Posterior lumbar spinal fusions (PSF), using pedicle screws, are performed to treat many spinal pathologies, but misplaced pedicle screws can result in new postoperative neurological deficits. METHODS: Patients with pedicle screw stimulation testing who underwent PSF between 2010 and 2012 at the University of Pittsburgh Medical Center (UPMC) were included in the study. We evaluated the sensitivity, specificity, and diagnostic odds ratio (DOR) to determine how effectively low pedicle screw responses predict new postoperative lower extremity neurological deficits. RESULTS: One thousand one hundred seventy nine eligible patients underwent 8584 pedicle screw stimulations with lower extremity somatosensory evoked potentials (LE SSEP) monitoring for lumbar fusion surgery. One hundred twenty one of these patients had 187 pedicle screws with a stimulation response at a threshold less than or equal to 8 mA. Smoking had a significant correlation to pedicle screw stimulation less than or equal to 8 mA (P = 0.012). A threshold of less than or equal to 8 mA had a sensitivity/specificity of 0.32/0.90 with DOR of 4.34 [1.83, 10.27] and an area under the ROC curve (AUC) of 0.61 [0.49, 0.74]. Patients with screw thresholds less than or equal to 8 mA and abnormal baselines had a DOR of 9.8 [95% CI: 2.13-45.17] and an AUC of 0.73 [95% CI: 0.50-0.95]. CONCLUSION: Patients with pedicle screw stimulation thresholds less than or equal to 8 mA are 4.34 times more likely to have neurological clinical manifestations. Smoking and LE deficits were shown to be significantly correlated with pedicle screw stimulation thresholds less than or equal to 8 mA. Low stimulation thresholds result in a high specificity of 90%. Pedicle screw stimulation less than or equal to 8 mA can serve as an accurate rule in test for postoperative neurological deficit, warranting reevaluation of screw placement and/or replacement intraoperatively.Level of Evidence: 3.


Subject(s)
Lumbosacral Region/surgery , Pedicle Screws , Spinal Fusion/methods , Adolescent , Adult , Aged , Aged, 80 and over , Electromyography , Female , Humans , Lower Extremity , Lumbar Vertebrae/surgery , Male , Middle Aged , Postoperative Period , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL