Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 182
Filter
1.
Ear Hear ; 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38915137

ABSTRACT

OBJECTIVES: A wide variety of intraoperative tests are available in cochlear implantation. However, no consensus exists on which tests constitute the minimum necessary battery. We assembled an international panel of clinical experts to develop, refine, and vote upon a set of core consensus statements. DESIGN: A literature review was used to identify intraoperative tests currently used in the field and draft a set of provisional statements. For statement evaluation and refinement, we used a modified Delphi consensus panel structure. Multiple interactive rounds of voting, evaluation, and feedback were conducted to achieve convergence. RESULTS: Twenty-nine provisional statements were included in the original draft. In the first voting round, consensus was reached on 15 statements. Of the 14 statements that did not reach consensus, 12 were revised based on feedback provided by the expert practitioners, and 2 were eliminated. In the second voting round, 10 of the 12 revised statements reached a consensus. The two statements which did not achieve consensus were further revised and subjected to a third voting round. However, both statements failed to achieve consensus in the third round. In addition, during the final revision, one more statement was decided to be deleted due to overlap with another modified statement. CONCLUSIONS: A final core set of 24 consensus statements was generated, covering wide areas of intraoperative testing during CI surgery. These statements may provide utility as evidence-based guidelines to improve quality and achieve uniformity of surgical practice.

2.
Sensors (Basel) ; 24(11)2024 May 22.
Article in English | MEDLINE | ID: mdl-38894099

ABSTRACT

Cochlear implants are crucial for addressing severe-to-profound hearing loss, with the success of the procedure requiring careful electrode placement. This scoping review synthesizes the findings from 125 studies examining the factors influencing insertion forces (IFs) and intracochlear pressure (IP), which are crucial for optimizing implantation techniques and enhancing patient outcomes. The review highlights the impact of variables, including insertion depth, speed, and the use of robotic assistance on IFs and IP. Results indicate that higher insertion speeds generally increase IFs and IP in artificial models, a pattern not consistently observed in cadaveric studies due to variations in methodology and sample size. The study also explores the observed minimal impact of robotic assistance on reducing IFs compared to manual methods. Importantly, this review underscores the need for a standardized approach in cochlear implant research to address inconsistencies and improve clinical practices aimed at preserving hearing during implantation.


Subject(s)
Cochlear Implantation , Cochlear Implants , Humans , Cochlear Implantation/methods , Pressure , Cochlea/surgery , Cochlea/physiology , Robotic Surgical Procedures/methods , Robotics/methods , Hearing Loss/surgery , Hearing Loss/physiopathology
3.
Laryngoscope Investig Otolaryngol ; 9(3): e1263, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38855776

ABSTRACT

Objectives: To establish audiological and other outcomes following cochlear implantation in humans and animals with eluting electrodes. Methods: Systematic review and narrative synthesis. Databases searched (April 2023): MEDLINE, EMBASE, CENTRAL, ClinicalTrials.gov, and Web of Science. Studies reporting outcomes in either humans or animals following cochlear implantation with a drug-eluting electrode were included. No limits were placed on language or year of publication. Risk of bias assessment was performed on all included studies using either the Brazzelli or Systematic Review Centre for Laboratory animal Experimentation (SYRCLE) assessment tools. The review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 statement. Results: Searches identified 146 abstracts and 108 full texts. Of these, 18 studies met the inclusion criteria, reporting outcomes in 523 animals (17 studies) and 24 humans (1 study). Eluting electrodes included dexamethasone (16 studies), aracytine (1 study), nicotinamide adenine dinucleotide (1 study), the growth factors insulin-like growth factor 1 (IGF1) and hepatocyte growth factor (HGF) (1 study), and neurotrophin-3 (1 study). All included studies compare outcomes following implantation with an eluting electrode with a control non-eluting electrode. In the majority of studies, audiological outcomes (e.g., auditory brainstem response threshold) were superior following implantation with an eluting electrode compared with a standard electrode. Most studies which investigated post-implantation impedance reported lower impedance following implantation with an eluting electrode. The influence of eluting electrodes on other reported outcomes (including post-implantation cochlear fibrosis and the survival of hair cells and spiral ganglion neurons) was more varied across the included studies. Conclusions: Eluting electrodes have shown promise in animal studies in preserving residual hearing following cochlear implantation and in reducing impedance, though data from human studies remain lacking. Further in-human studies will be required to determine the clinical usefulness of drug-eluting cochlear implants as a future treatment for sensorineural hearing loss.

4.
Sci Adv ; 10(26): eado9576, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38924408

ABSTRACT

Lip language recognition urgently needs wearable and easy-to-use interfaces for interference-free and high-fidelity lip-reading acquisition and to develop accompanying data-efficient decoder-modeling methods. Existing solutions suffer from unreliable lip reading, are data hungry, and exhibit poor generalization. Here, we propose a wearable lip language decoding technology that enables interference-free and high-fidelity acquisition of lip movements and data-efficient recognition of fluent lip language based on wearable motion capture and continuous lip speech movement reconstruction. The method allows us to artificially generate any wanted continuous speech datasets from a very limited corpus of word samples from users. By using these artificial datasets to train the decoder, we achieve an average accuracy of 92.0% across individuals (n = 7) for actual continuous and fluent lip speech recognition for 93 English sentences, even observing no training burn on users because all training datasets are artificially generated. Our method greatly minimizes users' training/learning load and presents a data-efficient and easy-to-use paradigm for lip language recognition.


Subject(s)
Speech , Wearable Electronic Devices , Humans , Language , Lip/physiology , Movement , Male , Female , Adult , Lipreading , Motion Capture
5.
PLoS Med ; 21(4): e1004296, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38573882

ABSTRACT

BACKGROUND: Patients with severe-to-profound hearing loss may benefit from management with cochlear implants. These patients need a referral to a cochlear implant team for further assessment and possible surgery. The referral pathway may result in varied access to hearing healthcare. This study aimed to explore referral patterns and whether there were any socioeconomic or ethnic associations with the likelihood of referral. The primary outcome was to determine factors influencing referral for implant assessment. The secondary outcome was to identify factors impacting whether healthcare professionals had discussed the option of referral. METHODS AND FINDINGS: A multicentre multidisciplinary observational study was conducted in secondary care Otolaryngology and Audiology units in Great Britain. Adults fulfilling NICE (2019) audiometric criteria for implant assessment were identified over a 6-month period between 1 July and 31 December 2021. Patient- and site-specific characteristics were extracted. Multivariable binary logistic regression was employed to compare a range of factors influencing the likelihood of implant discussion and referral including patient-specific (demographics, past medical history, and degree of hearing loss) and site-specific factors (cochlear implant champion and whether the hospital performed implants). Hospitals across all 4 devolved nations of the UK were invited to participate, with data submitted from 36 urban hospitals across England, Scotland, and Wales. Nine hospitals (25%) conducted cochlear implant assessments. The majority of patients lived in England (n = 5,587, 86.2%); the rest lived in Wales (n = 419, 6.5%) and Scotland (n = 233, 3.6%). The mean patient age was 72 ± 19 years (mean ± standard deviation); 54% were male, and 75·3% of participants were white, 6·3% were Asian, 1·5% were black, 0·05% were mixed, and 4·6% were self-defined as a different ethnicity. Of 6,482 submitted patients meeting pure tone audiometric thresholds for cochlear implantation, 311 already had a cochlear implant. Of the remaining 6,171, 35.7% were informed they were eligible for an implant, but only 9.7% were referred for assessment. When adjusted for site- and patient-specific factors, stand-out findings included that adults were less likely to be referred if they lived in more deprived area decile within Indices of Multiple Deprivation (4th (odds ratio (OR): 2·19; 95% confidence interval (CI): [1·31, 3·66]; p = 0·002), 5th (2·02; [1·21, 3·38]; p = 0·05), 6th (2·32; [1·41, 3·83]; p = 0.05), and 8th (2·07; [1·25, 3·42]; p = 0·004)), lived in London (0·40; [0·29, 0·57]; p < 0·001), were male (females 1·52; [1·27, 1·81]; p < 0·001), or were older (0·97; [0·96, 0·97]; p < 0·001). They were less likely to be informed of their potential eligibility if they lived in more deprived areas (4th (1·99; [1·49, 2·66]; p < 0·001), 5th (1·75; [1·31, 2·33], p < 0·001), 6th (1·85; [1·39, 2·45]; p < 0·001), 7th (1·66; [1·25, 2·21]; p < 0·001), and 8th (1·74; [1·31, 2·31]; p < 0·001) deciles), the North of England or London (North 0·74; [0·62, 0·89]; p = 0·001; London 0·44; [0·35, 0·56]; p < 0·001), were of Asian or black ethnic backgrounds compared to white patients (Asian 0·58; [0·43, 0·79]; p < 0·001; black 0·56; [0·34, 0·92]; p = 0·021), were male (females 1·46; [1·31, 1·62]; p < 0·001), or were older (0·98; [0·98, 0·98]; p < 0·001). The study methodology was limited by its observational nature, reliance on accurate documentation of the referring service, and potential underrepresentation of certain demographic groups. CONCLUSIONS: The majority of adults meeting pure tone audiometric threshold criteria for cochlear implantation are currently not appropriately referred for assessment. There is scope to target underrepresented patient groups to improve referral rates. Future research should engage stakeholders to explore the reasons behind the disparities. Implementing straightforward measures, such as educational initiatives and automated pop-up tools for immediate identification, can help streamline the referral process.


Subject(s)
Cochlear Implantation , Cochlear Implants , Hearing Loss, Sensorineural , Hearing Loss , Adult , Female , Humans , Male , Middle Aged , Aged , Aged, 80 and over , Hearing Loss, Sensorineural/surgery , Hearing Loss/surgery , Educational Status
6.
Nat Mater ; 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38671159

ABSTRACT

Electrode arrays that interface with peripheral nerves are used in the diagnosis and treatment of neurological disorders; however, they require complex placement surgeries that carry a high risk of nerve injury. Here we leverage recent advances in soft robotic actuators and flexible electronics to develop highly conformable nerve cuffs that combine electrochemically driven conducting-polymer-based soft actuators with low-impedance microelectrodes. Driven with applied voltages as small as a few hundreds of millivolts, these cuffs allow active grasping or wrapping around delicate nerves. We validate this technology using in vivo rat models, showing that the cuffs form and maintain a self-closing and reliable bioelectronic interface with the sciatic nerve of rats without the use of surgical sutures or glues. This seamless integration of soft electrochemical actuators with neurotechnology offers a path towards minimally invasive intraoperative monitoring of nerve activity and high-quality bioelectronic interfaces.

7.
PLoS One ; 19(3): e0299597, 2024.
Article in English | MEDLINE | ID: mdl-38452034

ABSTRACT

BACKGROUND: Extrusion of electrodes outside the cochlea and tip fold overs may lead to suboptimal outcomes in cochlear implant (CI) recipients. Intraoperative measures such as Trans-Impedance Matrix (TIM) measurements may enable clinicians to identify electrode malposition and direct surgeons to correctly place the electrode array during surgery. OBJECTIVES: To assess the current literature on the effectiveness of TIM measurements in identifying extracochlear electrodes and tip fold overs. METHODS: A scoping review of studies on TIM-based measurements were carried out using the Databases-Medline/PubMed, AMED, EMBASE, CINAHL and the Cochrane Library following PRISMA guidelines. Eleven full texts articles met the inclusion criteria. Only human studies pertaining to TIM as a tool used in CI were included in the review. Further, patient characteristics, electrode design, and TIM measurement outcomes were reported. RESULTS: TIM measurements were available for 550 implanted ears with the subjects age ranged between 9 months to 89 years. Abnormal TIM measurements were reported for 6.55% (36). Tip fold over was detected in 3.64% (20) of the cases, extracochlear electrodes in 1.45% (8), and 1.45% (8) were reported as buckling. Slim-modiolar electrode array designs were more common (54.71%) than pre-curved (23.34%) or lateral wall (21.95%) electrode array. Abnormal cochlear anatomy was reported for five ears (0.89%), with normal cochlear anatomy for all other patients. CONCLUSION: TIM measurement is a promising tool for the intraoperative detection of electrode malposition. TIM measurement has a potential to replace intraoperative imaging in future. Though, TIM measurement is in its early stages of clinical utility, intuitive normative data sets coupled with standardised criteria for detection of abnormal electrode positioning would enhance its sensitivity.


Subject(s)
Cochlear Implantation , Cochlear Implants , Humans , Cochlea/surgery , Cochlear Implantation/methods , Electric Impedance , Electrodes, Implanted , Treatment Outcome
8.
PLoS One ; 19(2): e0290480, 2024.
Article in English | MEDLINE | ID: mdl-38422002

ABSTRACT

Idiopathic sudden sensorineural hearing loss (ISSNHL) is the rapid onset of reduced hearing due to loss of function of the inner ear or hearing nerve of unknown aetiology. Evidence supports improved hearing recovery with early steroid treatment, via oral, intravenous, intratympanic or a combination of routes. The STARFISH trial aims to identify the most clinically and cost-effective route of administration of steroids as first-line treatment for ISSNHL. STARFISH is a pragmatic, multicentre, assessor-blinded, three-arm intervention, superiority randomised controlled trial (1:1:1) with an internal pilot (ISRCTN10535105, IRAS 1004878). 525 participants with ISSNHL will be recruited from approximately 75 UK Ear, Nose and Throat units. STARFISH will recruit adults with sensorineural hearing loss averaging 30dBHL or greater across three contiguous frequencies (confirmed via pure tone audiogram), with onset over a ≤3-day period, within four weeks of randomisation. Participants will be randomised to 1) oral prednisolone 1mg/Kg/day up to 60mg/day for 7 days; 2) intratympanic dexamethasone: three intratympanic injections 3.3mg/ml or 3.8mg/ml spaced 7±2 days apart; or 3) combined oral and intratympanic steroids. The primary outcome will be absolute improvement in pure tone audiogram average at 12-weeks following randomisation (0.5, 1.0, 2.0 and 4.0kHz). Secondary outcomes at 6 and 12 weeks will include: Speech, Spatial and Qualities of hearing scale, high frequency pure tone average thresholds (4.0, 6.0 and 8.0kHz), Arthur Boothroyd speech test, Vestibular Rehabilitation Benefit Questionnaire, Tinnitus Functional Index, adverse events and optional weekly online speech and pure tone hearing tests. A health economic assessment will be performed, and presented in terms of incremental cost effectiveness ratios, and cost per quality-adjusted life-year. Primary analyses will be by intention-to-treat. Oral prednisolone will be the reference. For the primary outcome, the difference between group means and 97.5% confidence intervals at each time-point will be estimated via a repeated measures mixed-effects linear regression model.


Subject(s)
Ear, Inner , Hearing Loss, Sensorineural , Adult , Humans , Audiometry, Pure-Tone , Hearing , Hearing Loss, Sensorineural/drug therapy , Multicenter Studies as Topic , Prednisolone/therapeutic use , Randomized Controlled Trials as Topic
9.
Laryngoscope ; 134(6): 2864-2870, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38214403

ABSTRACT

OBJECTIVE: Pure tone audiometry (PTA) is the gold standard for hearing assessment. However, it requires access to specialized equipment. Smartphone audiometry applications (apps) have been developed to perform automated threshold audiometry and could allow patients to perform self-administered screening or monitoring. This study aimed to assess the validity and feasibility of patients using apps to self-assess hearing thresholds at home, with comparison to PTA. METHODS: A multi-center, prospective randomized study was conducted amongst patients undergoing PTA in clinics. Participants were randomly allocated to one of four publicly-available apps designed to measure pure tone thresholds. Participants used an app once in optimal sound-treated conditions and a further three times at home. Ear-specific frequency-specific thresholds and pure tone average were compared using Pearson correlation coefficient. The percentage of app hearing tests with results within ±10 dB of PTA was calculated. Patient acceptability was assessed via an online survey. RESULTS: One hundred thirty-nine participants submitted data. The results of two at-home automated smartphone apps correlated strongly/very strongly with PTA average and their frequency-specific median was within ±10 dB accuracy. Smartphone audiometry performed in sound-treated and home conditions were very strongly correlated. The apps were rated as easy/very easy to use by 90% of participants and 90% would be happy/very happy to use an app to monitor their hearing. CONCLUSION: Judicious use of self-performed smartphone audiometry was both valid and feasible for two of four apps. It could provide frequency-specific threshold estimates at home, potentially allowing assessments of patients remotely or monitoring of fluctuating hearing loss. LEVEL OF EVIDENCE: 2 Laryngoscope, 134:2864-2870, 2024.


Subject(s)
Audiometry, Pure-Tone , Mobile Applications , Smartphone , Adult , Aged , Female , Humans , Male , Middle Aged , Young Adult , Audiometry, Pure-Tone/instrumentation , Audiometry, Pure-Tone/methods , Auditory Threshold/physiology , Feasibility Studies , Hearing Loss/diagnosis , Prospective Studies , Reproducibility of Results
10.
Clin Otolaryngol ; 49(1): 41-61, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37885344

ABSTRACT

OBJECTIVES: To assess outcomes associated with photobiomodulation therapy (PBMT) for hearing loss in human and animal studies. DESIGN: Systematic review and narrative synthesis in accordance with PRISMA guidelines. SETTING: Data bases searched: MEDLINE, EMBASE, CENTRAL, ClinicalTrials.gov and Web of Science. No limits were placed on language or year of publication. Review conducted in accordance with the PRISMA 2020 statement. PARTICIPANTS: All human and animal subjects treated with PBMT for hearing loss. MAIN OUTCOME MEASURES: Pre- and post-PBMT audio metric outcomes. RESULTS: Searches identified 122 abstracts and 49 full text articles. Of these, 17 studies met the inclusion criteria, reporting outcomes in 327 animals (11 studies), 30 humans (1 study), and 40 animal specimens (5 studies). PBMT parameters included 6 different wavelengths: 908 nm (1 study), 810 nm (1 study), 532 & 635 nm (1 study), 830 nm (3 studies), 808 nm (11 studies). The duration ranged from 4 to 60 minutes in a session, and the follow-up ranged from 5-28 days. Outcomes improved significantly when wavelengths within the range of 800-830 nm were used, and with greater duration of PBMT exposure. Included studies predominantly consisted of non-randomized controlled trials (10 studies). CONCLUSIONS: Hearing outcomes following PBMT appear to be superior to no PBMT for subjects with hearing loss, although higher level evidence is required to verify this. PBMT enables concentrated, focused delivery of light therapy to the inner ear through a non-invasive manner with minimal side effects. As a result of heterogeneity in reporting PBMT parameters and outcomes across the included studies, direct comparison is challenging.


Subject(s)
Hearing Loss , Low-Level Light Therapy , Animals , Humans , Hearing , Hearing Loss/radiotherapy
11.
Eur Arch Otorhinolaryngol ; 281(3): 1115-1129, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37930386

ABSTRACT

PURPOSE: This study is a systematic review of the literature which seeks to evaluate auditory and quality of life (QOL) outcomes of cochlear implantation in patients with Usher syndrome. METHODS: Systematic review of studies indexed in Medline via PubMed, Ovid EMBASE, Web of Science, CENTRAL and clinicaltrials.gov was performed up to March 9th 2022, conducted in accordance with the PRISMA statement. Patient demographics, comorbidity, details of cochlear implantation, auditory, and QOL outcomes were extracted and summarized. RESULTS: 33 studies reported over 217 cochlear implants in 187 patients with Usher syndrome, comprising subtypes 1 (56 patients), 2 (9 patients), 3 (23 patients), and not specified (99 patients). Auditory outcomes included improved sound detection, speech perception, and speech intelligibility. QOL outcomes were reported for 75 patients, with benefit reported in the majority. CONCLUSIONS: Many patients with Usher syndrome develop improved auditory outcomes after cochlear implantation with early implantation being an important factor.


Subject(s)
Cochlear Implantation , Cochlear Implants , Speech Perception , Usher Syndromes , Humans , Usher Syndromes/surgery , Quality of Life , Treatment Outcome
12.
J Laryngol Otol ; : 1-22, 2023 Nov 23.
Article in English | MEDLINE | ID: mdl-37994052

ABSTRACT

OBJECTIVE: To establish outcomes following photobiomodulation therapy for tinnitus in humans and animal studies. METHODS: A systematic review and narrative synthesis was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. The databases searched were: Medline, Embase, Cochrane Central Register of Controlled Trials ('Central'), ClinicalTrials.gov and Web of Science including the Web of Science Core collection. There were no limits on language or year of publication. RESULTS: The searches identified 194 abstracts and 61 full texts. Twenty-eight studies met the inclusion criteria, reporting outcomes in 1483 humans (26 studies) and 34 animals (2 studies). Photobiomodulation therapy parameters included 10 different wavelengths, and duration ranged from 9 seconds to 30 minutes per session. Follow up ranged from 7 days to 6 months. CONCLUSION: Tinnitus outcomes following photobiomodulation therapy are generally positive and superior to no photobiomodulation therapy; however, evidence of long-term therapeutic benefit is deficient. Photobiomodulation therapy enables concentrated, focused delivery of light therapy to the inner ear through a non-invasive manner, with minimal side effects.

13.
Otol Neurotol ; 44(10): e730-e738, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-37889939

ABSTRACT

OBJECTIVE: To determine if there is a difference in hearing outcomes or stimulation levels between Advanced Bionics straight and precurved arrays. STUDY DESIGN: Retrospective chart review across three implant centers. SETTING: Tertiary centers for cochlear and auditory brainstem implantation. PATIENTS: One hundred fifteen pediatric and 205 adult cochlear implants (CIs) were reviewed. All patients were implanted under the National Institute for Health and Care Excellence 2009 guidelines with a HiRes Ultra SlimJ or Mid-Scala electrode array. MAIN OUTCOME MEASURES: Hearing preservation after implantation, as well as CI-only listening scores for Bamford-Kowal-Bench sentences were compared 1 year after implantation. Stimulation levels for threshold and comfort levels were also compared 1 year after implantation. RESULTS: Hearing preservation was significantly better with the SlimJ compared with the Mid-Scala electrode array. Bamford-Kowal-Bench outcomes were not significantly different between the two arrays in any listening condition. Stimulation levels were not different between arrays but did vary across electrode contacts. At least one electrode was deactivated in 33% of implants but was more common for the SlimJ device. CONCLUSION: Modern straight and precurved arrays from Advanced Bionics did not differ in hearing performance or current requirements. Although hearing preservation was possible with both devices, the SlimJ array would still be the preferred electrode in cases where hearing preservation was a priority. Unfortunately, the SlimJ device was also prone to poor sound perception on basal electrodes. Further investigation is needed to determine if deactivated electrodes are associated with electrode position/migration, and if programming changes are needed to optimize the use of these high-frequency channels.


Subject(s)
Cochlear Implantation , Cochlear Implants , Adult , Humans , Child , Retrospective Studies , Bionics , Cochlea/surgery
14.
Otol Neurotol ; 44(9): 881-889, 2023 10 01.
Article in English | MEDLINE | ID: mdl-37621122

ABSTRACT

HYPOTHESIS: There are clinically relevant differences in scalae anatomy and spiral ganglion neuron (SGN) quantity between incomplete partition type II (IP-II) and normal cochleae. BACKGROUND: IP-II is a commonly implanted cochlear malformation. Detailed knowledge of intracochlear three-dimensional (3D) morphology may assist with cochlear implant (CI) electrode selection/design and enable optimization of audiologic programming based on SGN maps. METHODS: IP-II (n = 11) human temporal bone histological specimens were identified from the National Institute on Deafness and Other Communication Disorders National Temporal Bone Registry and digitized. The cochlear duct, scalae, and surgically relevant anatomy were reconstructed in 3D. A machine learning algorithm was applied to map the location and number of SGNs. RESULTS: 3D scalae morphology of the basal turn was normal. Scala tympani (ST) remained isolated for 540 degrees before fusing with scala vestibuli. Mean ST volume reduced below 1 mm 2 after the first 340 degrees. Scala media was a distinct endolymphatic compartment throughout; mean ± standard deviation cochlear duct length was 28 ± 3 mm. SGNs were reduced compared with age-matched norms (mean, 48%; range, 5-90%). In some cases, SGNs failed to ascend Rosenthal's canal, remaining in an abnormal basalward modiolar location. Two forms of IP-II were seen: type A and type B. A majority (98-100%) of SGNs were located in the basal modiolus in type B IP-II, compared with 76 to 85% in type A. CONCLUSION: Hallmark features of IP-II cochleae include the following: 1) fusion of the ST and scala vestibuli at a mean of 540 degrees, 2) highly variable and overall reduced SGN quantity compared with normative controls, and 3) abnormal SGN distribution with cell bodies failing to ascend Rosenthal's canal.


Subject(s)
Cochlea , Cochlear Implants , Humans , Cochlea/diagnostic imaging , Scala Tympani , Scala Vestibuli , Cochlear Duct
15.
Laryngoscope Investig Otolaryngol ; 8(4): 1094-1107, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37621295

ABSTRACT

Objective: This systematic review aims to establish the expected hearing and speech outcomes following cochlear implantation (CI) in patients with profound congenital deafness secondary to Waardenburg syndrome (WS). Methods: A systematic review of the literature and narrative synthesis was performed in accordance with the PRISMA statement. Databases searched: Medline, Pubmed, Embase, Web of Science, Cochrane Collection, and ClinicalTrials.gov. No limits were placed on language or year of publication. Results: Searches identified 186 abstracts and full texts. Of these, 16 studies met inclusion criteria reporting outcomes in 179 patients and at least 194 implants. Hearing outcomes of those receiving cochlear implantation were generally good. Five studies included genetic analysis of one or more of the participants. A total of 11 peri/post-operative complications were reported. The methodological quality of included studies was modest, mainly comprising noncontrolled case series with small cohort size. All studies were OCEBM grade III-IV. Conclusion: Cochlear implantation in congenitally deafened children with Waardenburg Syndrome is a well-established intervention as a method of auditory rehabilitation. Due to the uncommon nature of the condition, there is a lack of large-scale high-quality studies examining the use of cochlear implantation in this patient group. However, overall outcomes following implantation are positive with the majority of patients demonstrating improved audiometry, speech perception and speech intelligibility supporting its use in appropriately selected cases.

16.
Adv Sci (Weinh) ; 10(29): e2301756, 2023 10.
Article in English | MEDLINE | ID: mdl-37485646

ABSTRACT

Astrocytes are diverse brain cells that form large networks communicating via gap junctions and chemical transmitters. Despite recent advances, the functions of astrocytic networks in information processing in the brain are not fully understood. In culture, brain slices, and in vivo, astrocytes, and neurons grow in tight association, making it challenging to establish whether signals that spread within astrocytic networks communicate with neuronal groups at distant sites, or whether astrocytes solely respond to their local environments. A multi-electrode array (MEA)-based device called AstroMEA is designed to separate neuronal and astrocytic networks, thus allowing to study the transfer of chemical and/or electrical signals transmitted via astrocytic networks capable of changing neuronal electrical behavior. AstroMEA demonstrates that cortical astrocytic networks can induce a significant upregulation in the firing frequency of neurons in response to a theta-burst charge-balanced biphasic current stimulation (5 pulses of 100 Hz × 10 with 200 ms intervals, 2 s total duration) of a separate neuronal-astrocytic group in the absence of direct neuronal contact. This result corroborates the view of astrocytic networks as a parallel mechanism of signal transmission in the brain that is separate from the neuronal connectome. Translationally, it highlights the importance of astrocytic network protection as a treatment target.


Subject(s)
Astrocytes , Gap Junctions , Gap Junctions/physiology , Neurons , Brain
17.
Otol Neurotol ; 44(7): 627-635, 2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37317518

ABSTRACT

OBJECTIVE: The objective of this study is to determine the rate of postoperative meningitis after cochlear implantation in those with inner ear malformations (IEMs) via meta-analysis. DATA SOURCES: Medline, EMBASE, and the Cochrane Library. METHODS: This study was reported following the preferred reporting items for systematic reviews and meta-analyses (PRISMA) checklist. Proportion meta-analysis was conducted through an inverse variance random-effect model based on arcsin transformation and presented as forest plots. Quality assessment of the included studies was performed through the National Institutes of Health Quality Assessment Tool. RESULTS: Overall, 38 of 2966 studies met the inclusion criteria and were included in the analysis. There were 10 cases of meningitis after cochlear implantation in 1300 malformed ears. The overall rate of meningitis after cochlear implantation in IEMs was 0.12% (95% confidence interval, 0.006-0.380%; I2 = 0%). Cases occurred in incomplete partition (n = 5), Mondini deformity (n = 2), common cavity (n = 2), and enlarged internal auditory canal (n = 1). Six of 10 cases of postoperative meningitis occurred with an intraoperative cerebrospinal fluid leak. CONCLUSION: In those with IEMs, the risk of meningitis after cochlear implantation is very low.


Subject(s)
Cochlear Implantation , Cochlear Implants , Ear, Inner , Meningitis , Humans , Cochlear Implantation/adverse effects , Cochlear Implants/adverse effects , Ear, Inner/surgery , Treatment Outcome , Retrospective Studies , Meningitis/epidemiology , Meningitis/etiology
18.
Adv Healthc Mater ; 12(24): e2300732, 2023 09.
Article in English | MEDLINE | ID: mdl-37310792

ABSTRACT

Cochlear implants are a life-changing technology for those with severe sensorineural hearing loss, partially restoring hearing through direct electrical stimulation of the auditory nerve. However, they are known to elicit an immune response resulting in fibrotic tissue formation in the cochlea that is linked to residual hearing loss and suboptimal outcomes. Intracochlear fibrosis is difficult to track without postmortem histology, and no specific electrical marker for fibrosis exists. In this study, a tissue-engineered model of cochlear fibrosis is developed following implant placement to examine the electrical characteristics associated with fibrotic tissue formation around electrodes. The model is characterized using electrochemical impedance spectroscopy and an increase in the resistance and a decrease in capacitance of the tissue using a representative circuit are found. This result informs a new marker of fibrosis progression over time that is extractable from voltage waveform responses, which can be directly measured in cochlear implant patients. This marker is tested in a small sample size of recently implanted cochlear implant patients, showing a significant increase over two postoperative timepoints. Using this system, complex impedance is demonstrated as a marker of fibrosis progression that is directly measurable from cochlear implants to enable real-time tracking of fibrosis formation in patients, creating opportunities for earlier treatment intervention to improve cochlear implant efficacy.


Subject(s)
Cochlear Implantation , Cochlear Implants , Humans , Electric Impedance , Cochlea/physiology , Cochlear Implantation/adverse effects , Fibrosis
19.
Clin Otolaryngol ; 48(4): 638-647, 2023 07.
Article in English | MEDLINE | ID: mdl-37051731

ABSTRACT

OBJECTIVES: To estimate the prevalence of, and risk factors associated with electrode migration (EM) in cochlear implant (CI) recipients. DESIGN: Historical cohort study of all CIs performed between 1 January 2018 and 1 August 2021 in a single tertiary adult and paediatric CI centre in the UK. MAIN OUTCOME MEASURES: The primary aim is to determine the prevalence of electrode migration, comparing intraoperative surgeon report and examination of a routine plain radiograph performed 2 weeks after surgery. EM is defined as the detection of movement of two or more electrodes out of the cochlea from the time of surgery. Multivariate analysis was performed to investigate preoperative and intraoperative risk factors that might predispose to migration. RESULTS: Four hundred and sixty-five patients, having 516 distinct surgeries, with 628 implants were analysed. EM occurred following 11.5% of implant operations. Pre-existing cochlear abnormality was an independent associated risk factor for EM (OR: 3.40 ⟨1.20-9.62⟩ p = .021). Demographics, surgical technique, usage of a precurved electrode, CSF leak, surgeon seniority and intraoperative telemetry did not influence risk of migration. There were 5 implants (0.8%) which migrated later than 2 weeks, with a median date of imaging diagnosis (x-ray or CT scan) of 263 days ⟨IQR:198⟩, for which head injury was a common precipitating factor. There were differences in the risk of migration between different lateral wall electrodes. CONCLUSION: EM in the early postoperative period is a common occurrence and is more likely in implant recipients with obstructed or malformed cochleae.


Subject(s)
Cochlear Implantation , Cochlear Implants , Child , Adult , Humans , Cochlear Implantation/methods , Cohort Studies , Electrodes, Implanted , Retrospective Studies , Cochlear Implants/adverse effects , Postoperative Period
SELECTION OF CITATIONS
SEARCH DETAIL
...