J Chromatogr B Analyt Technol Biomed Life Sci ; 852(1-2): 450-8, 2007 Jun 01.
Article in English | MEDLINE | ID: mdl-17369000

ABSTRACT

We describe the development and validation of a method for the simultaneous quantification of 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), 3-hydroxy-4-methoxymethamphetamine (HMMA), 3-hydroxy-4-methoxyamphetamine (HMA), 3,4-methylenedioxyethylamphetamine (MDEA), methamphetamine (MAMP) and amphetamine (AMP) in sweat. Drugs were eluted from PharmChek sweat patches with sodium acetate buffer, extracted with disk solid phase extraction and analyzed using GC/MS-EI with selected ion monitoring. Limits of quantification (LOQ) for MDMA, MDEA, MAMP and AMP were 2.5 ng/patch, and 5 ng/patch for MDA, HMA and HMMA. This fully validated procedure was more sensitive than previously published analytical methods and permitted the simultaneous analysis of multiple amphetamine analogs in human sweat.


Subject(s)
Amphetamines/analysis , Sweat/chemistry , Gas Chromatography-Mass Spectrometry , Humans , Reproducibility of Results , Sensitivity and Specificity