Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
Food Microbiol ; 36(2): 416-25, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24010624

ABSTRACT

A flow cytometric method (RAPID-B™) with detection sensitivity of one viable cell of Escherichia coli serotype O157:H7 in fresh spinach (Spinacia oleracea) was developed and evaluated. The major impediment to achieving this performance was mistaking autofluorescing spinach particles for tagged target cells. Following a 5 h non-selective enrichment, artificially inoculated samples were photobleached, using phloxine B as a photosensitizer. Samples were centrifuged at high speed to concentrate target cells, then gradient centrifuged to separate them from matrix debris. In external laboratory experiments, RAPID-B and the reference method both correctly detected E. coli O157:H7 at inoculations of ca. 15 cells. In a follow-up study, after 4 cell inoculations of positives and 6 h enrichment, RAPID-B correctly identified 92% of 25 samples. The RAPID-B method limit of detection (LOD) was one cell in 25 g. It proved superior to the reference method (which incorporated real time-PCR, selective enrichment, and culture plating elements) in accuracy and speed.


Subject(s)
Eosine I Bluish/pharmacology , Escherichia coli O157/chemistry , Escherichia coli O157/isolation & purification , Flow Cytometry/methods , Photosensitizing Agents/pharmacology , Spinacia oleracea/microbiology , Consumer Product Safety , Escherichia coli O157/drug effects , Escherichia coli O157/radiation effects , Flow Cytometry/instrumentation , Food Contamination/analysis , Photobleaching
3.
Astrobiology ; 9(8): 745-58, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19845446

ABSTRACT

It has been widely understood for many years that an essential component of a Mars Sample Return mission is a Sample Receiving Facility (SRF). The purpose of such a facility would be to take delivery of the flight hardware that lands on Earth, open the spacecraft and extract the sample container and samples, and conduct an agreed-upon test protocol, while ensuring strict containment and contamination control of the samples while in the SRF. Any samples that are found to be non-hazardous (or are rendered non-hazardous by sterilization) would then be transferred to long-term curation. Although the general concept of an SRF is relatively straightforward, there has been considerable discussion about implementation planning. The Mars Exploration Program carried out an analysis of the attributes of an SRF to establish its scope, including minimum size and functionality, budgetary requirements (capital cost, operating costs, cost profile), and development schedule. The approach was to arrange for three independent design studies, each led by an architectural design firm, and compare the results. While there were many design elements in common identified by each study team, there were significant differences in the way human operators were to interact with the systems. In aggregate, the design studies provided insight into the attributes of a future SRF and the complex factors to consider for future programmatic planning.


Subject(s)
Equipment Design , Extraterrestrial Environment , Mars , Space Flight , Spacecraft , Containment of Biohazards , Exobiology , Humans
4.
J Food Prot ; 66(3): 441-5, 2003 Mar.
Article in English | MEDLINE | ID: mdl-12636298

ABSTRACT

Phosphatidylinositol-specific phospholipase C (PI-PLC) activity is a potential virulence factor and is exhibited only by the Listeria species Listeria monocytogenes and Listeria ivanovii. A chromogenic substrate for the direct detection of PI-PLC activity is available in a new medium (BCM L. monocytogenes plating agar). The use of a chromogenic substrate offers a mechanism with which to directly screen for L. monocytogenes and L. ivanovii other than the esculin used in Oxford (OXF) and Palcam (PAL) agars, which screen for all Listeria species. The specificity levels of BCM plating agar and of BCM confirmation and rhamnose agars were evaluated with 107 Listeria and 10 Bacillus species isolates. In addition, BCM L. monocytogenes plating agar was compared with standard Listeria selective agars (OXF and PAL agars) with regard to the recovery of L. monocytogenes from 2,000 food and environmental samples obtained from eight participating laboratories. A Listeria species was isolated from at least one of the agars in 209 analyses, and L. monocytogenes was isolated in 135 of these analyses. In 27 of the analyses in which L. monocytogenes was isolated, one or more of the selective differential agars used failed to isolate L. monocytogenes, and therefore the results of these analyses were discrepant. Relative to a reference method involving the use of all three agars (OXF, PAL, and BCM agars), the OXF-BCM, PAL-BCM, and OXF-PAL combinations had sensitivities of 99.3, 99.2, and 90.2%, respectively. In statistical analyses of the different combinations of agars, the OXF-BCM and BCM-PAL combinations were found to be superior to the OXF-PAL combination for the detection of L. monocytogenes.


Subject(s)
Agar , Listeria monocytogenes/isolation & purification , Type C Phospholipases/analysis , Chromogenic Compounds , Colony Count, Microbial , Food Microbiology , Indicators and Reagents , Listeria monocytogenes/enzymology , Phosphatidylinositol Diacylglycerol-Lyase , Phosphoinositide Phospholipase C , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL