1.
J. bras. nefrol ; 46(2): e20230019, Apr.-June 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1550495

ABSTRACT

ABSTRACT Introduction: Contrast-associated acute kidney injury (CA-AKI) is a deterioration of kidney function that occurs after the administration of a iodinated contrast medium (ICM). Most studies that defined this phenomenon used older ICMs that were more prone of causing CA-AKI. In the past decade, several articles questioned the true incidence of CA-AKI. However, there is still a paucity of a data about the safety of newer ICM. Objective: To assess the incidence of CA-AKI in hospitalized patients that were exposed to computed tomography (CT) with and without ICM. Methods: Prospective cohort study with 1003 patients who underwent CT in a tertiary hospital from December 2020 through March 2021. All inpatients aged > 18 years who had a CT scan during this period were screened for the study. CA-AKI was defined as a relative increase of serum creatinine of ≥ 50% from baseline or an absolute increase of ≥ 0.3 mg/dL within 18 to 48 hours after the CT. Chi-squared test, Kruskal-Wallis test, and linear regression model with restricted cubic splines were used for statistical analyses. Results: The incidence of CA-AKI was 10.1% in the ICM-exposed group and 12.4% in the control group when using the absolute increase criterion. The creatinine variation from baseline was not significantly different between groups. After adjusting for baseline factors, contrast use did not correlate with worse renal function. Conclusion: The rate of CA-AKI is very low, if present at all, with newer ICMs, and excessive caution regarding contrast use is probably unwarranted.


RESUMO Introdução: Lesão renal aguda associada ao contraste (LRA-AC) é uma deterioração da função renal que ocorre após a administração de meio de contraste iodado (MCI). A maioria dos estudos que definiram esse fenômeno utilizaram MCI mais antigos, mais propensos a causar LRA-AC. Na última década, diversos artigos questionaram a verdadeira incidência de LRA-AC. Entretanto, ainda há escassez de dados sobre a segurança dos MCI mais novos. Objetivo: Avaliar a incidência de LRA-AC em pacientes hospitalizados expostos à tomografia computadorizada (TC) com e sem MCI. Métodos: Estudo de coorte prospectivo com 1.003 pacientes submetidos a TC em hospital terciário, de dezembro/2020 a março/2021. Todos os pacientes internados com idade ≥ 18 anos que realizaram TC nesse período foram selecionados. A LRA-AC foi definida como aumento relativo de creatinina sérica de ≥ 50% em relação ao valor basal ou aumento absoluto de ≥ 0,3 mg/dL dentro de 18 a 48 horas após a TC. Utilizamos o teste qui-quadrado, teste de Kruskal-Wallis e modelo de regressão linear com splines cúbicos restritos para análises estatísticas. Resultados: A incidência de LRA-AC foi 10,1% no grupo exposto ao MCI e 12,4% no grupo controle ao usar o critério de aumento absoluto. A variação da creatinina em relação ao valor basal não foi significativamente diferente entre os grupos. Após ajuste para fatores basais, o uso de contraste não se correlacionou com pior função renal. Conclusão: A taxa de LRA-AC é muito baixa, caso exista, com MCIs mais novos, e a cautela excessiva quanto ao uso de contraste provavelmente não se justifica.

2.
J Bras Nefrol ; 46(2): e20230019, 2024.
Article in English, Portuguese | MEDLINE | ID: mdl-37791792

ABSTRACT

INTRODUCTION: Contrast-associated acute kidney injury (CA-AKI) is a deterioration of kidney function that occurs after the administration of a iodinated contrast medium (ICM). Most studies that defined this phenomenon used older ICMs that were more prone of causing CA-AKI. In the past decade, several articles questioned the true incidence of CA-AKI. However, there is still a paucity of a data about the safety of newer ICM. OBJECTIVE: To assess the incidence of CA-AKI in hospitalized patients that were exposed to computed tomography (CT) with and without ICM. METHODS: Prospective cohort study with 1003 patients who underwent CT in a tertiary hospital from December 2020 through March 2021. All inpatients aged > 18 years who had a CT scan during this period were screened for the study. CA-AKI was defined as a relative increase of serum creatinine of ≥ 50% from baseline or an absolute increase of ≥ 0.3 mg/dL within 18 to 48 hours after the CT. Chi-squared test, Kruskal-Wallis test, and linear regression model with restricted cubic splines were used for statistical analyses. RESULTS: The incidence of CA-AKI was 10.1% in the ICM-exposed group and 12.4% in the control group when using the absolute increase criterion. The creatinine variation from baseline was not significantly different between groups. After adjusting for baseline factors, contrast use did not correlate with worse renal function. CONCLUSION: The rate of CA-AKI is very low, if present at all, with newer ICMs, and excessive caution regarding contrast use is probably unwarranted.


Subject(s)
Acute Kidney Injury , Contrast Media , Humans , Prospective Studies , Retrospective Studies , Incidence , Contrast Media/adverse effects , Acute Kidney Injury/chemically induced , Acute Kidney Injury/epidemiology , Creatinine , Risk Factors
3.
Movimento (Porto Alegre) ; 24(3): 1029-1040, jul.-set. 2018.
Article in Portuguese | LILACS | ID: biblio-969289

ABSTRACT

Este ensaio tem por objetivo analisar e debater criticamente o movimento denominado Escola sem Partido, discutindo sua origem, o contexto sociopolítico no qual ele se desenvolve e quais são as teses que o sustentam. Busca traçar um breve olhar pela área de conhecimento da Educação Física, especificamente pelo viés da perspectiva crítico-superadora, e quais são os desdobramentos e as consequências, imediatas e futuras, para o seu ensino e para o trabalho do professor no âmbito da escola pública. Por fim, sugere possibilidades e ações de enfrentamento ao discurso conservador em defesa de uma educação e uma Educação Física crítica em que alunos e alunas sejam sujeitos ativos do processo de ensino-aprendizagem


This essay aims to analyze and critically discuss the movement called "schools without parties", looking into its origin, the socio-political context in which it develops and the arguments that sustain it. It attempts to take a brief look at it through the Physical Education knowledge area, specifically through the critical-overcoming perspective, and see what its immediate and future ramifications and consequences are for PE teaching and PE teachers' work in the public school context. Finally, it suggests possibilities and actions to confront the conservative discourse and advocate critical education and Physical Education in which students are active subjects of the teaching-learning process


Este ensayo tiene por objetivo analizar y debatir críticamente el movimiento denominado "Escuela sin Partido", discutiendo su origen, el contexto sociopolítico en el que se desarrolla y cuáles son las tesis que lo sostienen. Busca lanzar una breve mirada por el área de conocimiento de la Educación Física, específicamente por el sesgo de la perspectiva crítico-superadora, y cuáles son los desdoblamientos y las consecuencias,inmediatas y futuras, para la enseñanza y para el trabajo del profesor en el ámbito de la educación pública. Por último, sugiere posibilidades y acciones de enfrentamiento al discurso conservador en defensa de una educación y de una Educación Física crítica, donde alumnos y alumnas sean sujetos activos del proceso de enseñanza y aprendizaje


Subject(s)
Humans , Physical Education and Training , Public Policy , Teaching , Education
4.
Pensar prát. (Impr.) ; 19(2): 339-349, abr.-jun.2016.
Article in Portuguese | LILACS | ID: biblio-912859

ABSTRACT

Este artigo discute o processo de proletarização docente, mais especificamente no âmbito da Educação Física Escolar. Partindo de uma leitura materialista dialética de educação, foi realizada uma pesquisa de cunho qualitativo com professores da Rede Municipal de Ensino de Porto Alegre, no qual procuramos compreender como os professores organizam seu trabalho pedagógico frente a esse processo, que decorre da aproximação cada vez maior das condições do trabalho docente com as características do trabalho da sociedade capitalista.


This paper discusses the process of teacher proletarianization, more specifically in the context of Physical Education at school. From a dialectical materialist reading of education, it carried out a qualitative research with professors of the Municipal School of Porto Alegre, in which we seek to understand how teachers organize their pedagogical work against this process, which stems from the increasing approximation of teaching conditions to the characteristics of capitalist society work.


En este trabajo se analiza el proceso de proletarización docente, más concretamente en el contexto de la educación física en la escuela. De una lectura dialéctica materialista de la educación, se realizó una investigación cualitativa con los profesores de Escuelas Municipales de Porto Alegre, en el que buscamos comprender cómo los profesores organizan su trabajo pedagógico frente a este proceso, que se deriva de la creciente aproximación de las condiciones de lo trabajo docente a las características del trabajo de la sociedad capitalista.


Subject(s)
Humans , Physical Education and Training , Schools
5.
J Am Coll Cardiol ; 66(19): 2075-2088, 2015 Nov 10.
Article in English | MEDLINE | ID: mdl-26541917

ABSTRACT

BACKGROUND: Cardiac biomarker release signifying myocardial injury post-transcatheter aortic valve replacement (TAVR) is common, yet its clinical impact within a large TAVR cohort receiving differing types of valve and procedural approaches is unknown. OBJECTIVES: This study sought to determine the incidence, clinical impact, and factors associated with cardiac biomarker elevation post TAVR. METHODS: This multicenter study included 1,131 consecutive patients undergoing TAVR with balloon-expandable (58%) or self-expandable (42%) valves. Transfemoral and transapical (TA) approaches were selected in 73.1% and 20.3% of patients, respectively. Creatine kinase-myocardial band (CK-MB) measurements were obtained at baseline and at several time points within the initial 72 h post TAVR. Echocardiography was performed at baseline and at 6- to 12-month follow-up. RESULTS: Overall, 66% of the TAVR population demonstrated some degree of myocardial injury as determined by a rise in CK-MB levels (peak value: 1.6-fold [interquartile range (IQR): 0.9 to 2.8-fold]). A TA approach and major procedural complications were independently associated with higher peak of CK-MB levels (p < 0.01 for all), which translated into impaired systolic left ventricular function at 6 to 12 months post TAVR (p < 0.01). A greater rise in CK-MB levels independently associated with an increased 30-day, late (median of 21 [IQR: 8 to 36] months) overall and cardiovascular mortality (p < 0.001 for all). Any increase in CK-MB levels was associated with poorer clinical outcomes, and there was a stepwise rise in late mortality according to the various degrees of CK-MB increase after TAVR (p < 0.001). CONCLUSIONS: Some degree of myocardial injury was detected in two-thirds of patients post TAVR, especially in those undergoing TA-TAVR or presenting with major procedural complications. A greater rise in CK-MB levels associated with greater acute and late mortality, imparting a negative impact on left ventricular function.


Subject(s)
Aortic Valve Stenosis/surgery , Myocardial Reperfusion Injury/etiology , Registries , Risk Assessment , Transcatheter Aortic Valve Replacement/adverse effects , Aged, 80 and over , Echocardiography , Europe/epidemiology , Female , Follow-Up Studies , Humans , Incidence , Male , Myocardial Reperfusion Injury/diagnosis , Myocardial Reperfusion Injury/epidemiology , North America/epidemiology , Retrospective Studies , South America/epidemiology , Time Factors
6.
Rev. bras. cardiol. invasiva ; 23(4): 238-241, out.-dez. 2015. tab, graf
Article in Portuguese | LILACS | ID: biblio-846502

ABSTRACT

Introdução: A válvula aórtica transcateter de segunda geração LotusTM foi desenhada para proporcionar ao intervencionista o controle completo de sua liberação durante o procedimento. O presente estudo apresenta a experiência inicial e os desfechos hospitalares de pacientes tratados com essa prótese no Brasil. Métodos: Registro observacional, retrospectivo, que incluiu pacientes com estenose aórtica grave sintomáticos, considerados de alto risco cirúrgico, tratados em sete centros.Resultados: Receberam o dispositivo 31 pacientes, sendo 61,3% do sexo feminino, com idade de 82,9 ± 6,9 anos e escore STS de 6,5 ± 4,1%. A área valvar aórtica foi de 0,73 ± 0,18 cm2 e o gradiente médio de 51,7 ± 13,9 mmHg. Todos os procedimentos foram realizados pela via transfemoral, e a pré-dilatação foi necessária em 65% dos casos. A taxa de sucesso do procedimento foi de 96,7%. Não houve complicação vascular com necessidade de intervenção cirúrgica e nem casos de acidente vascular cerebral. O gradiente médio após o procedimento foi de 10,5 ± 5,8 mmHg e não foram observadas regurgitações aórticas de graus moderado/importante. A taxa de implante de marca-passo definitivo foi de 38,7%, e a permanência hospitalar de 8,5 ± 4,8 dias. Conclusões: Na experiência inicial com o implante da válvula aórtica LotusTM, os resultados hospitalares demostraram a segurança e a eficácia do dispositivo, além de ausência de regurgitação aórtica relevante


Background: The second-generation LotusTM transcatheter aortic valve was designed to provide the interventional cardiologist with complete control of its release during the procedure. This study presents the initial experience and in-hospital outcomes of patients treated with this prosthesis in Brazil. Methods: This observational and retrospective study included patients with symptomatic severe aortic stenosis considered at high surgical risk, treated in seven centers. Results: The device was used in 31 patients, 61.3% female, aged 82.9 ± 6.9 years, and with STS score of 6.5 ± 4.1%. The aortic valve area was 0.73 ± 0.18 cm2 and the mean gradient was 51.7 ± 13.9 mmHg. All procedures were performed by the transfemoral access route, and pre-dilation was necessary in 65% of cases. The success rate of the procedure was 96.7%. There were no vascular complications requiring surgical intervention nor cases of stroke. The mean gradient after the procedure was 10.5 ± 5.8 mmHg; no cases of moderate to severe aortic regurgitation were observed. The rate of permanent pacemaker implantation was 38.7%, and mean in-hospital length of stay was 8.5 ± 4.8 days. Conclusions: In the initial experience with the use of the LotusTM aortic valve, in-hospital results demonstrated the safety and efficacy of the device; no cases of significant aortic regurgitation were observed


Subject(s)
Humans , Male , Female , Aged , Aortic Valve/surgery , Prostheses and Implants , Defibrillators, Implantable , Aortic Valve Stenosis/therapy , Bioprosthesis/trends , Risk Factors , Observational Study , Heart Failure/therapy , Heart Valves/surgery , Heart Ventricles/physiopathology
7.
J. Am. Coll. Cardiol ; J. Am. Coll. Cardiol;65(05): 437-448, 2015. ilus
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1063741

ABSTRACT

BACKGROUND Little evidence exists of the burden and predictors of cardiac death after transcatheter aortic valvereplacement (TAVR).OBJECTIVES The purpose of this study was to assess the incidence and predictors of cardiac death from advancedheart failure (HF) and sudden cardiac death (SCD) in a large patient cohort undergoing TAVR.METHODS The study included a total of 3,726 patients who underwent TAVR using balloon (57%) or self-expandable(43%) valves. Causes of death were defined according to the Valve Academic Research Consortium–2.RESULTS At a mean follow-up of 22 18 months, 155 patients had died due to advanced HF (15.2% of total deaths,46.1% of deaths from cardiac causes) and 57 had died due to SCD (5.6% of deaths, 16.9% of cardiac deaths). Baselinecomorbidities (chronic obstructive pulmonary disease, atrial fibrillation, left ventricular ejection fraction #40%, lowermean transaortic gradient, pulmonary artery systolic pressure >60 mm Hg; p 160 ms had a greater SCD risk (HR: 4.78, 95% CI: 1.56 to 14.63; p » 0.006).CONCLUSIONS Advanced HF and SCD accounted for two-thirds of cardiac deaths in patients after TAVR.Potentially modifiable or treatable factors leading to increased risk of mortality for HF and SCD were identified. Future.


Subject(s)
Heart Failure , Death, Sudden , Transcatheter Aortic Valve Replacement
9.
Rev. bras. anestesiol ; Rev. bras. anestesiol;63(3): 279-286, maio-jun. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-675846

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: A estenose aórtica (EA) grave é uma doença prevalente e de grande mortalidade. Nos pacientes idosos com outras comorbidades o implante valvar percutâneo é uma opção. OBJETIVOS: Descrever o manejo anestésico e as complicações com anestesia geral. MÉTODO: Série de casos com seguimento de 30 dias e 24 meses após o implante do dispositivo CoreValve feito no Instituto de Cardiologia/Fundação Universitária de Cardiologia entre dezembro de 2008 e janeiro de 2012. Os pacientes foram submetidos à anestesia geral monitorada com pressão arterial média (PAM), eletrocardiograma (ECG), oximetria, capnografia, ecocardiograma transesofágico, termometria e marcapasso transvenoso. RESULTADOS: Foram submetidos com sucesso ao implante valvular 28 pacientes, com idade média de 82,46 anos, EuroScore médio de 20,98%, classe funcional III/IV. Nove pacientes necessitaram de implante de marcapasso definitivo. No seguimento dos pacientes houve dois óbitos, um no transoperatório por perfuração do VE e um no terceiro dia por causa desconhecida. Em 24 meses um paciente faleceu com diagnóstico de mieloma múltiplo. A técnica anestésica mostrou-se segura. CONCLUSÃO: A experiência inicial com implante valvular aórtico percutâneo sob anestesia geral tem se mostrado segura e eficaz sem complicações anestésicas importantes para esse procedimento.


BACKGROUND AND OBJECTIVE: Aortic stenosis is a highly prevalent and life-threatening disease. In elderly patients with comorbidities, percutaneous valve implantation is an option. The aim of the study was to describe the anesthetic management and complications of general anesthesia. METHOD: Case series with 30-day and 24-month follow-ups after implantation of the CoreValve device performed at the Institute of Cardiology/University Foundation of Cardiology between December 2008 and January 2012. The patients underwent general anesthesia monitored with mean arterial pressure (PAM), electrocardiogram (ECG), pulse oximetry, capnography, transesophageal echocardiography, thermometry, and transvenous pacemaker. RESULTS: Twenty-eight patients, mean age 82.46 years, 20.98% mean EuroSCORE, functional class III/IV, successfully underwent valve implantation. Nine patients required permanent pacemaker implantation. During follow-up, two patients died: one during surgery due to LV perforation and the other on the third day of unknown causes. At 24 months, one patient diagnosed with multiple myeloma died. This anesthetic technique proved to be safe. CONCLUSION: The initial experience with percutaneous aortic valve implantation under general anesthesia has proven to be safe and effective, with no significant anesthetic complications during this procedure.


JUSTIFICATIVA Y OBJETIVOS: La estenosis aórtica (EA) grave es una enfermedad prevalente y de gran mortalidad. En los pacientes ancianos con otras comorbilidades, el implante valvular percutáneo es una opción. OBJETIVOS: Describir el manejo anestésico y las complicaciones con la anestesia general. MÉTODO: Serie de casos con seguimiento de 30 días y 24 meses después del implante del dispositivo CoreValve hecho en el Instituto de Cardiología/Fundación Universitaria de Cardiología entre diciembre de 2008 y enero de 2012. Los pacientes fueron sometidos a la anestesia general monitorizada con una presión arterial promedio (PAP), electrocardiograma (ECG), oximetría, capnografía, ecocardiograma transesofágico, termometría y marcapaso transvenoso. RESULTADOS: Fueron sometidos con éxito al implante valvular 28 pacientes, con una edad promedio de 82,46 años, EuroScore medio de 20,98%, clase funcional III/IV. Nueve pacientes necesitaron implante de marcapaso definitivo. En el seguimiento de los pacientes hubo dos decesos, uno en el transoperatorio por perforación del VI y uno al tercer día por causa desconocida. En 24 meses un paciente falleció con diagnóstico de mieloma múltiple. La técnica anestésica fue segura. CONCLUSIONES: La experiencia inicial con implante valvular aórtico percutáneo bajo anestesia general ha sido segura y eficaz sin complicaciones anestésicas importantes para ese procedimiento.


Subject(s)
Aged , Aged, 80 and over , Child , Female , Humans , Male , Middle Aged , Anesthesia, General/adverse effects , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Longitudinal Studies , Prosthesis Design
10.
Braz J Anesthesiol ; 63(3): 279-86, 2013.
Article in English, Portuguese, Spanish | MEDLINE | ID: mdl-23683452

ABSTRACT

BACKGROUND AND OBJECTIVE: Aortic stenosis is a highly prevalent and life-threatening disease. In elderly patients with comorbidities, percutaneous valve implantation is an option. The aim of the study was to describe the anesthetic management and complications of general anesthesia. METHOD: Case series with 30-day and 24-month follow-ups after implantation of the CoreValve device performed at the Institute of Cardiology/University Foundation of Cardiology between December 2008 and January 2012. The patients underwent general anesthesia monitored with mean arterial pressure (PAM), electrocardiogram (ECG), pulse oximetry, capnography, transesophageal echocardiography, thermometry, and transvenous pacemaker. RESULTS: Twenty-eight patients, mean age 82.46 years, 20.98% mean EuroSCORE, functional class III/IV, successfully underwent valve implantation. Nine patients required permanent pacemaker implantation. During follow-up, two patients died: one during surgery due to LV perforation and the other on the third day of unknown causes. At 24 months, one patient diagnosed with multiple myeloma died. This anesthetic technique proved to be safe. CONCLUSION: The initial experience with percutaneous aortic valve implantation under general anesthesia has proven to be safe and effective, with no significant anesthetic complications during this procedure.


Subject(s)
Anesthesia, General/adverse effects , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/methods , Aged , Aged, 80 and over , Child , Female , Heart Valve Prosthesis , Humans , Longitudinal Studies , Male , Middle Aged , Prosthesis Design
12.
Rev. bras. cardiol. invasiva ; 20(3): 267-273, 2012. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-656090

ABSTRACT

INTRODUÇÃO: A intervenção coronária percutânea (ICP) primária é o principal método de reperfusão em pacientes com infarto do miocárdio com supradesnivelamento do segmento ST (IAMCSST). A trombectomia por aspiração manual tem sido cada vez mais utilizada e possibilita a análise dos trombos aspirados. MÉTODOS: Pacientes consecutivos submetidos a ICP primária foram incluídos no período de dezembro de 2009 a junho de 2011. As características clínicas e laboratoriais e os dados angiográficos foram coletados prospectivamente e incluídos em banco de dados dedicado. A decisão de realizar tromboaspiração ficou a cargo dos operadores. Foram coletadas 112 amostras de trombos, armazenadas em formalina 10%, fixadas em parafina, coradas com hematoxilina-eosina, e analisadas por microscopia óptica. Na avaliação histopatológica, os trombos foram classificados em trombos recentes ou lisados/organizados. RESULTADOS: Foram identificados trombos recentes em 68 pacientes (61%) e trombos lisados/organizados em 44 pacientes (39%). Os pacientes com trombos recentes apresentaram maior infiltração de glóbulos vermelhos (P = 0,03). Não foram identificadas outras diferenças estatisticamente significantes em relação às características clínicas, angiográficas e laboratoriais ou aos desfechos clínicos entre os dois grupos estudados. CONCLUSÕES: Em pacientes com IAMCSST submetidos a ICP primária, dois terços dos trombos aspirados apresentaram características histopatológicas de trombos recentes. Não foram observadas associações significativas entre essas características e aspectos clínicos, laboratoriais e angiográficos nesta amostra contemporânea e representativa do mundo real.


BACKGROUND: Primary percutaneous coronary intervention (primary PCI) is the preferred reperfusion method in patients with ST-segment elevation myocardial infarction (STEMI). Manual aspiration thrombectomy has been increasingly used and enables the analysis of thrombus aspirates. METHODS: Consecutive patients undergoing primary PCI were enrolled from December 2009 to June 2011. Clinical, laboratory and angiographic data were prospectively collected and entered in a dedicated database. The decision to perform thromboaspiration was left to the discretion of the operators. One hundred and twelve samples of thrombi were collected, stored in 10% formalin-fixed paraffin, stained with hematoxylin-eosin and analyzed by light microscopy. On histopathological evaluation, the thrombi were classified as recent thrombi or lysed/organized thrombi. RESULTS: Recent thrombi were identified in 68 patients (61%) and lysed/organized thrombi in 44 patients (39%). Patients with recent thrombi had higher red blood cell infiltration (P = 0.03). There were no other statistically significant differences identified for clinical, angiographic, laboratory or clinical outcomes between the two study groups. CONCLUSIONS: In patients with STEMI undergoing primary PCI, two-thirds of thrombus aspirates showed histopathological features of recent thrombi. There were no significant associations between these characteristics and clinical, laboratory and angiographic data in this contemporary sample representative of the real world.


Subject(s)
Humans , Male , Female , Middle Aged , Angioplasty , Myocardial Infarction/complications , Myocardial Infarction/mortality , Prospective Studies , Coronary Thrombosis/complications , Electrocardiography/methods , Electrocardiography
13.
Rev. bras. cardiol. invasiva ; 19(4): 367-372, dez. 2011. tab, ilus
Article in Portuguese | LILACS | ID: lil-618781

ABSTRACT

Introdução: O implante valvular aórtico percutâneo (IVAP) vem se desenvolvendo rapidamente nos últimos anos. A manipulação da valva aórtica degenerada pode acarretar complicações. O IVAP direto, sem pré-dilatação com balão e com menor manipulação, seria uma alternativa. O objetivo deste estudo é apresentar uma série de 8 casos de IVAP direto com seguimento a médio prazo realizado no Instituto de Cardiologia do Rio Grande do Sul. Métodos: Série de 8 casos com descrição da técnica e resultados imediatos e a médio prazo do implante do dispositivo CoreValveTM sem valvuloplastia com balão. Resultados: No total, 7 pacientes do sexo masculino e 1 do sexo feminino, com média de idade de 76 anos e EuroSCORE logístico variando de 6 a 62, foram submetidos ao implante do dispositivo CoreValveTM. Houve significativa queda dos gradientes entre o ventrículo esquerdo e a aorta. Foram registrados três casos de insucesso do implante, um óbito no período pós-implante imediato e um óbito aos 6 meses, sem relação com o procedimento. No seguimento de um ano, não houve novos casos de implante de marca-passo e eventos embólicos. Conclusões: O IVAP direto sem pré-dilatação com balão mostrou-se uma alternativa potencialmente eficaz. Quando realizado com sucesso, determina melhora dos sintomas, diminuição sustentável do gradiente transvalvar aórtico e aumento da área valvar aórtica. Não está claro, contudo, qual o paciente e qual a condição anatômica ideal para essa abordagem. Estudos adicionais e seguimento mais prolongado ainda são necessários para definir o exato papel e as precisas indicações dessa variação da técnica.


Subject(s)
Humans , Male , Aged , Catheterization , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnosis , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aortic Valve/surgery , Aspirin/administration & dosage , Risk Factors
15.
Rev. bras. cardiol. invasiva ; 19(1): 28-33, mar. 2011.
Article in Portuguese | LILACS | ID: lil-591715

ABSTRACT

Introdução: A estenose aórtica é uma afecção prevalente e com altas taxas de morbidade e mortalidade, sendo atroca valvular cirúrgica a abordagem clássica. Indivíduos idosos e com outras comorbidades apresentam elevadorisco operatório. O implante valvular aórtico percutâneo surge como alternativa à cirurgia padrão. O objetivo deste estudo é apresentar o seguimento de dois anos dos primeiros casos realizados no Sul do Brasil com essa abordagem inédita. Métodos: Série de casos com descrição da técnica e resultados imediatos e a médio prazo do implante do dispositivo CoreValveTM (Medtronic Inc., Minneapolis, EstadosUnidos), que consiste de uma bioprótese de pericárdio porcino montada em stent auto expansível de nitinol, introduzido pela via arterial. Resultados: Foram submetidos ao implante desse dispositivo quatro pacientes do sexo feminino, com idade variando entre 81 anos e 90 anos e EuroSCORE logístico de 20% a 36%. Observou-se significativa queda do gradiente ventrículo esquerdo-aorta, assim como ausência de complicações cardiovasculares maiores, embora duas pacientes tenham necessitado de implante de marca-passo definitivo por distúrbio de condução atrioventricular.No seguimento de dois anos observou-se melhora da classe funcional e manutenção dos gradientes e das áreas valvares aórticas alcançadas no final do procedimentoe diminuição progressiva da massa ventricular esquerda. Conclusões: Esta experiência inicial com implante valvularaórtico percutâneo tem se mostrando segura e efetiva em análise a médio prazo. Estudos com seguimento a longoprazo são necessários para definir o exato papel e precisas indicações dessa nova e promissora técnica.


Background: Aortic stenosis is a prevalent disease with high morbidity and mortality, whose classical approach is surgical valve replacement. Elderly patients and those with other comorbidities present high surgical risk. Transcatheter aortic valve implantation is an effective alternative to standardsurgery. The objective of this study is to report the 2-year follow-up of the first cases performed in Southern Brazil.Methods: Series of cases describing the technique, immediate and medium term results of the CoreValveTM (Medtronic Inc., Minneapolis, USA) device implantation, a porcine pericardialbioprosthesis mounted on a self expanding nitinol stent, delivered via transarterial access. Results: Four female patients, with ages ranging from 81 to 90 years and a logistic EuroSCORE ranging from 20% to 36% were successfully submitted to the implantation of this device. A significantreduction in the left ventricle-aortic gradient, and no major cardiovascular complications were observed, although2 patients required the implantation of a permanent pacemaker due to complete atrioventricular block. Improvementof functional class and maintenance of gradients and aortic valve areas obtained at the end of the procedure,as well as a progressive decrease of left ventricular mass were observed in the 2 year follow-up. Conclusions: Thisearly experience with the CoreValveTM transcatheter aortic valve implantation has proved to be safe and effective in the medium term outcome. Long-term follow-up studies are required to define the exact role and adequate indicationsfor this new and promising technology.


Subject(s)
Humans , Female , Aged , Aged, 80 and over , Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aspirin/administration & dosage , Echocardiography
16.
Rev. bras. cardiol. invasiva ; 18(4): 412-418, dez. 2010. tab
Article in Portuguese | LILACS | ID: lil-582207

ABSTRACT

INTRODUÇÃO: Existem poucos estudos contemporâneos avaliando o implante de stent direto em pacientes com infarto agudo do miocárdio com supradesnivelamento do segmento ST (IAM). Método: Estudo de coorte prospectivo com pacientes consecutivamente atendidos com IAM em um centro de referêncioa em cardiologia entre dezembro de 2009 e janeiro de 2010. Dados clínicos e laboratoriais, características angiográficas e evolução hospitalar foram avaliados. Foram excluídos pacientes com mais de 12 horas de evolução, com menos de 18 anos de idade ou por recusa em participar do estudo. Os pacientes submetidos a implante de stent direto foram comparados àqueles tratados com pré-dilatação. Os dados foram armazenados em banco de dados dedicado e analisados com SPSS 17.0. Resultados: No período de estudo, 98 pacientes foram submetidos a angioplastia primária, dos quais em 33 (34,7 por cento) foi implantado stent direto e em 65 (65,3 por cento) foi realizada pré-dilatação. A média de idade dos 98 pacientes foi de 58,6 +- 10,6 anos e 63 por cento eram do sexo masculino. Os procedimentos com stent direto foram menos frequentes em lesões calcificadas (9 por cento vs. 30 por cento; P + 0,02) e mais frequentes naqueles com TIMI 3 pré-procedimento (41 por cento vs. 18 por cento; P=0,06), sendo a tromboaspiração...


BACKGROUND: There are few contemporary studies assessing direct stenting in patients with acute ST-segment elevation myocardial infarction (AMI). METHOD: Prospective cohort study in consecutive patients with AMI seen at a reference cardiology center from December 2009 to January 2010. Clinical and laboratory data, angiographic characteristics and hospital outcomes were evaluated. Patients with over 12 hours of symptom onset, with less than 18 years of age and those who denied participating in the study were excluded. Patients undergoing direct stenting were compared to those treated with stent with balloon pre-dilatation. Data were entered in a dedicated database and analyzed by SPSS 17.0. RESULTS: During the study period, 98 patients were submitted to primary angioplasty, of which 33 (34.7%) received direct stenting and 65 (65.3%) underwent stent with balloon pre-dilatation. Mean age was 58.6 ± 10.6 years and 63% were men. Direct stenting was less frequent in calcified lesions (9% vs. 30%; P = 0.02) and more frequent in those with TIMI 3 before the procedure (41% vs. 18%; P = 0.06) and thrombus aspiration was more frequently used in these cases (41% vs. 14%; P = 0.003). There was no statistically significant difference for the clinical outcome in both groups of patients. CONCLUSION: Direct stenting was more frequently used in patients with normal flow prior the procedure and in combination with thrombus aspiration and less used in calcified lesions. It was not associated to significant differences in clinical outcome rates.


Subject(s)
Humans , Male , Female , Middle Aged , Angioplasty/methods , Angioplasty , Myocardial Infarction/complications , Stents , Prospective Studies , Risk Factors
17.
Rev. méd. Paraná ; 65(1): 15-19, jan.-jun. 2007. tab, graf
Article in Portuguese | LILACS | ID: lil-500710

ABSTRACT

A aterosclerose contribui significativamente para a taxa de mortalidade e morbidade no mundo ocidental. Os fatores de risco que predispõem à aterosclerose e consequente cardiopatia isquêmica foram identificados por vários estudos prospectivos em grupos definidos da população, mais especificamente o estudo Framingham Heart Study. Objetivos: Avaliar os fatores de risco clínicos e laboratoriais que acometem pacientes idosos e realizar análise associativa dos fatores de risco que acometeram esta população através dos cores de Framingham e a classificação dos indivíduos em baíxo, médio e alto risco para doença arterial coronariana. Material e Métodos: O presente estudo se desenvolveu no Asilo Dom Bosco de Itajaí (SC). A coleta de dados foi realizada na forma de anamnse clínica e anãlise clínica laboratorial para avaliação da glicemia, níveis de colesterol toral e HDL- colesterol. Foram analisados 51 idosos, sendo 19 homens e 32 mulheres com uma média de idade de 83,9 anos. Resultados: Os fatores de risco mais prevalentes observados foram hipertensão arterial sistêmica (HAS) e níveis alterados de colesterol total em ambos os sexos. Mais da metade dos homens, 52% apresentaram alto risco, 37% médio e 11% baixo risco, enquanto nas mulheres os valores encontrados foram 72% baixo e 28% médio risco, não sendo observado alto risco. Conclusão: Apesar da idade avançada ser um fator de risco não modificável, pode-se diminuir o risco cardíaco na população idosa através do controle dos demais fatores, como HAS e colesterol total, que neste estudo, foram determinantes na estratificação de risco da população avaliada.


Subject(s)
Male , Female , Middle Aged , Arteriosclerosis , Risk Factors , Aged
SELECTION OF CITATIONS