Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters











Database
Language
Publication year range
1.
Global Spine J ; : 21925682241270100, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39091072

ABSTRACT

STUDY DESIGN: Systematic Review. OBJECTIVES: To evaluate which cervical deformity correction technique between anterior cervical discectomy and fusion (ACDF) and anterior cervical corpectomy and fusion (ACCF) produces better clinical, radiographic, and operative outcomes. METHODS: We conducted a meta-analysis comparing studies involving ACDF and ACCF. Adult patients with either original or previously treated cervical spine deformities were included. Two independent reviewers categorized extracted data into clinical, radiographic, and operative outcomes, including complications. Clinical assessments included patient-reported outcomes; radiographic evaluations examined C2-C7 Cobb angle, T1 slope, T1-CL, C2-7 SVA, and graft stability. Surgical measures included surgery duration, blood loss, hospital stay, and complications. RESULTS: 26 studies (25727 patients) met inclusion criteria and were extracted. Of these, 14 studies (19077 patients) with low risk of bias were included in meta-analysis. ACDF and ACCF similarly improve clinical outcomes in terms of JOA and NDI, but ACDF is significantly better at achieving lower VAS neck scores. ACDF is also more advantageous for improving cervical lordosis and minimizing the incidence of graft complications. While there is no significant difference between approaches for most surgical complications, ACDF is favorable for reducing operative time, intraoperative blood loss, and length of hospital stay. CONCLUSIONS: While both techniques benefit cervical deformity patients, when both techniques are feasible, ACDF may be superior with respect to VAS neck scores, cervical lordosis, graft complications and certain perioperative outcomes. Further studies are recommended to address outcome variability and refine surgical approach selection.

2.
Spine J ; 2024 Aug 22.
Article in English | MEDLINE | ID: mdl-39173914

ABSTRACT

BACKGROUND: The accurate and safe positioning of cervical pedicle screws is crucial. While augmented reality (AR) use in spine surgery has previously demonstrated clinical utility in the thoracolumbar spine, its technical feasibility in the cervical spine remains less explored. PURPOSE: The objective of this study was to assess the precision and safety of AR-assisted pedicle screw placement in the cervical spine. STUDY DESIGN: In this experimental study, 5 cadaveric cervical spine models were instrumented from C3 to C7 by 5 different spine surgeons. The navigation accuracy and clinical screw accuracy were evaluated. METHODS: Postprocedural CT scans were evaluated for clinical accuracy by 2 independent neuroradiologists using the Gertzbein-Robbins scale. Technical precision was assessed by calculating the angular trajectory (°) and linear screw tip (mm) deviations in the axial and sagittal planes from the virtual pedicle screw position as recorded by the AR-guided platform during the procedure compared to the actual pedicle screw position derived from postprocedural imaging. RESULTS: A total of forty-one pedicle screws were placed in 5 cervical cadavers, with each of the 5 surgeons navigating at least 7 screws. Gertzbein-Robbins grade of A or B was achieved in 100% of cases. The mean values for tip and trajectory errors in the axial and sagittal planes between the virtual versus actual position of the screws was less than 3 mm and 30°, respectively (p<.05). None of the cervical screws violated the cortex by more than 2 mm or displaced neurovascular structures. CONCLUSIONS: AR-assisted cervical pedicle screw placement in cadavers demonstrated clinical accuracy comparable to existing literature values for image-guided navigation methods for the cervical spine. CLINICAL SIGNIFICANCE: This study provides technical and clinical accuracy data that supports clinical trialing of AR-assisted subaxial cervical pedicle screw placement.

3.
Oper Neurosurg (Hagerstown) ; 27(3): 316-321, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38531089

ABSTRACT

BACKGROUND AND OBJECTIVE: There are many surgical approaches for execution of a thoracic corpectomy. In cases of challenging deformity, traditional posterior approaches might not be sufficient to complete the resection of the vertebral body. In this technical note, we describe indications and technique for a transdural multilevel high thoracic corpectomy. METHODS: A 25-year-old man with a history of neurofibromatosis type 1 presented with instrumentation failure after a previous T1-T12 posterior spinal fusion, extensive laminectomy, and tumor resection. The patient presented with progressive back pain, had broad dural ectasia, and a progressive kyphotic rotational and anteriorly translated spinal deformity. To resect the medial-most aspect of the vertebral body, a bilateral extracavitary approach was attempted, but was found insufficient. A transdural approach was subsequently performed. A left paramedian durotomy was made, followed by generous arachnoid dissection, bilateral dentate ligament division, and T4 rootlet sacrifice to mobilize the spinal cord. A ventral durotomy was then made and the ventral dura was reflected over the spinal cord to protect it while drilling. The corpectomy was then completed. The ventral and dorsal durotomies were closed primarily and reinforced with fibrin glue and fibrin sealant patch. The corpectomy defect was filled with nonstructural autograft. RESULTS: The focal kyphosis was corrected with a combination of rod contouring, compression, and in situ bending. During the surgery, the patient had stable neuromonitoring data, and postoperatively had no neurological deficits. On follow-up until 1 year, the patient presented with no signs of cerebrospinal spinal leaks, no motor or sensory deficits, minimal incisional pain, and significantly improved posture. CONCLUSION: Complex high thoracic (T3-5) ventral pathology inaccessible via a bilateral extracavitary approach may be accessed via a transdural approach as opposed to an anterior/lateral transthoracic approach that requires mobilization of cardiovascular structures or scapula.


Subject(s)
Thoracic Vertebrae , Humans , Male , Adult , Thoracic Vertebrae/surgery , Thoracic Vertebrae/diagnostic imaging , Plastic Surgery Procedures/methods , Dura Mater/surgery , Spinal Fusion/methods , Laminectomy/methods , Neurofibromatosis 1/surgery , Neurofibromatosis 1/complications
4.
Medicina (Kaunas) ; 60(2)2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38399619

ABSTRACT

Background and Objectives: Advances in virtual reality (VR), augmented reality (AR), and mixed reality (MR) technologies have resulted in their increased application across many medical specialties. VR's main application has been for teaching and preparatory roles, while AR has been mostly used as a surgical adjunct. The objective of this study is to discuss the various applications and prospects for VR, AR, and MR specifically as they relate to spine surgery. Materials and Methods: A systematic review was conducted to examine the current applications of VR, AR, and MR with a focus on spine surgery. A literature search of two electronic databases (PubMed and Scopus) was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). The study quality was assessed using the MERSQI score for educational research studies, QUACS for cadaveric studies, and the JBI critical appraisal tools for clinical studies. Results: A total of 228 articles were identified in the primary literature review. Following title/abstract screening and full-text review, 46 articles were included in the review. These articles comprised nine studies performed in artificial models, nine cadaveric studies, four clinical case studies, nineteen clinical case series, one clinical case-control study, and four clinical parallel control studies. Teaching applications utilizing holographic overlays are the most intensively studied aspect of AR/VR; the most simulated surgical procedure is pedicle screw placement. Conclusions: VR provides a reproducible and robust medium for surgical training through surgical simulations and for patient education through various platforms. Existing AR/MR platforms enhance the accuracy and precision of spine surgeries and show promise as a surgical adjunct.


Subject(s)
Augmented Reality , Spine , Virtual Reality , Humans , Patient Education as Topic/methods , Spine/surgery
5.
Medicina (Kaunas) ; 60(2)2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38399568

ABSTRACT

Background and Objectives: Augmented reality head-mounted display (AR-HMD) is a novel technology that provides surgeons with a real-time CT-guided 3-dimensional recapitulation of a patient's spinal anatomy. In this case series, we explore the use of AR-HMD alongside more traditional robotic assistance in surgical spine trauma cases to determine their effect on operative costs and perioperative outcomes. Materials and Methods: We retrospectively reviewed trauma patients who underwent pedicle screw placement surgery guided by AR-HMD or robotic-assisted platforms at an academic tertiary care center between 1 January 2021 and 31 December 2022. Outcome distributions were compared using the Mann-Whitney U test. Results: The AR cohort (n = 9) had a mean age of 66 years, BMI of 29.4 kg/m2, Charlson Comorbidity Index (CCI) of 4.1, and Surgical Invasiveness Index (SII) of 8.8. In total, 77 pedicle screws were placed in this cohort. Intra-operatively, there was a mean blood loss of 378 mL, 0.78 units transfused, 398 min spent in the operating room, and a 20-day LOS. The robotic cohort (n = 13) had a mean age of 56 years, BMI of 27.1 kg/m2, CCI of 3.8, and SII of 14.2. In total, 128 pedicle screws were placed in this cohort. Intra-operatively, there was a mean blood loss of 432 mL, 0.46 units transfused units used, 331 min spent in the operating room, and a 10.4-day LOS. No significant difference was found between the two cohorts in any outcome metrics. Conclusions: Although the need to address urgent spinal conditions poses a significant challenge to the implementation of innovative technologies in spine surgery, this study represents an initial effort to show that AR-HMD can yield comparable outcomes to traditional robotic surgical techniques. Moreover, it highlights the potential for AR-HMD to be readily integrated into Level 1 trauma centers without requiring extensive modifications or adjustments.


Subject(s)
Augmented Reality , Spinal Fusion , Surgery, Computer-Assisted , Humans , Aged , Middle Aged , Surgery, Computer-Assisted/methods , Retrospective Studies , Fluoroscopy/methods , Spinal Fusion/methods
6.
Cell Growth Differ ; 13(9): 409-20, 2002 Sep.
Article in English | MEDLINE | ID: mdl-12354750

ABSTRACT

The D-group cyclins play a key role in the progression of cells through the G(1) phase of the cell cycle. Treatment of MCF-7 breast cancer cells with the cyclopentenone prostaglandin 15-deoxy-Delta(12,14)-PGJ(2) (15d-PGJ(2)) results in rapid down-regulation of cyclin D1 protein expression and growth arrest in the G(0)/G(1) phase of the cell cycle. 15d-PGJ(2) also down-regulates the expression of cyclin D1 mRNA; however, this effect is delayed relative to the effect on cyclin D1 protein levels, suggesting that the regulation of cyclin D1 occurs at least partly at the level of translation or protein turnover. Treatment of MCF-7 cells with 15d-PGJ(2) leads to a rapid increase in the phosphorylation of protein synthesis initiation factor eukaryotic initiation factor 2alpha (eIF-2alpha) and a shift of cyclin D1 mRNA from the polysome-associated to free mRNA fraction, indicating that 15d-PGJ(2) inhibits the initiation of cyclin D1 mRNA translation. The selective rapid decrease in cyclin D1 protein accumulation is facilitated by its rapid turnover (t(1/2) = 34 min) after inhibition of cyclin D1 protein synthesis. The half-life of cyclin D1 protein is not significantly altered in cells treated with 15d-PGJ(2). Treatment of cells with 15d-PGJ(2) results in strong induction of heat shock protein 70 (HSP70) gene expression, suggesting that 15d-PGJ(2) might activate protein kinase R (PKR), an eIF-2alpha kinase shown previously to be responsive to agents that induce stress. 15d-PGJ(2) strongly stimulates eIF-2alpha phosphorylation and down-regulates cyclin D1 expression in a cell line derived from wild-type mouse embryo fibroblasts but has an attenuated effect in PKR-null cells, providing evidence that PKR is involved in mediating the effect of 15d-PGJ(2) on eIF-2alpha phosphorylation and cyclin D1 expression. In summary, treatment of MCF-7 cells with 15d-PGJ(2) results in increased phosphorylation of eIF-2alpha and inhibition of cyclin D1 mRNA translation initiation. At later time points, repression of cyclin D1 mRNA expression may also contribute to the decrease in cyclin D1 protein.


Subject(s)
Cyclin D1/physiology , Protein Biosynthesis , Blotting, Northern , Blotting, Western , Cyclin D1/metabolism , Dose-Response Relationship, Drug , Down-Regulation , Flow Cytometry , Humans , Immunologic Factors/pharmacology , Models, Chemical , Phosphorylation , Polyribosomes/metabolism , Prostaglandin D2/analogs & derivatives , Prostaglandin D2/pharmacology , RNA, Messenger/metabolism , Time Factors , Tumor Cells, Cultured
SELECTION OF CITATIONS
SEARCH DETAIL