Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
Anal Sci ; 40(4): 599-607, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38190076

ABSTRACT

Vitamin D3 (VD3) is the main form of vitamin D and an essential nutrient for maintaining human life. Currently, traditional methods for detecting 25-hydroxyvitamin D3(25(OH)D3) are complex and expensive. In this study, we constructed an accurate, sensitive, simple, and cost-effective label-free biosensor based on an aptamer for the detection of 25(OH)D3. The aptamer-modified sulfhydryl adopted self-assembly as a way to stably immobilize at the glassy carbon electrode (GCE) surface modified by gold nanoparticles (AuNPs). Upon 25(OH)D3 binding to the aptamer, the complexes inhibit electron transfer at the electrode surface, leading to reduced [Fe(CN)6]3-/4- redox peak current. Consequently, the quantity of 25(OH)D3 that interacts with the electrode-bound aptamer correlates with the observed electric current response values. The Aptamer/AuNPs/GCE aptasensor achieved direct and highly sensitive detection of 25(OH)D3 over a wide concentration range (1.0-1000 nM), with a limit of detection of 1.0 nM. At the same time, other molecules with a similar structure, such as 25(OH)D2, Vitamin D3, and Vitamin D2, had lower response interference than 25(OH)D3. Therefore, this biosensor has great potential to become a portable diagnostic device for 25(OH)D3.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Metal Nanoparticles , Humans , Metal Nanoparticles/chemistry , Gold/chemistry , Calcifediol , Aptamers, Nucleotide/chemistry , Carbon/chemistry , Electrodes , Biosensing Techniques/methods , Vitamin D , Electrochemical Techniques/methods , Limit of Detection
2.
Curr Drug Metab ; 24(2): 139-147, 2023.
Article in English | MEDLINE | ID: mdl-37038713

ABSTRACT

BACKGROUND: Methotrexate (MTX) is a common folic acid antagonist in clinical medicine, easily inducing a common adverse side effect of liver and kidney injury. It has been found that the expression of Folylpolyglutamate Synthetase (FPGS) and gamma-Glutamyl Hydrolase (GGH) may be closely related to that of related proteins to affect the intracellular metabolism of MTX. OBJECTIVE: The relationship between FPGS/GGH and MTXPGs accumulation in liver and kidney cells was explored by adjusting the expression of FPGS and GGH in cells using UPLC-MS/MS quantitative technology. METHOD: Based on UPLC-MS/MS quantitative techniques, the relationship between MTXPGs accumulation and FPGS/GGH in hepatocytes and embryonic kidney cells was explored by adjusting the expression of FPGS and GGH, and the effect of FPGS/GGH on the intracellular toxicity of MTX was comprehensively analyzed. RESULT: The results showed that the difference in methotrexate polyglutamates (MTXPGs) accumulation in liver and kidney cells was related to the difference in FPGS and GGH expression. The expression of FPGS interacted with that of GGH. These results suggest that the protein abundance ratio of FPGS to GGH (FPGS/GGH) has more potential to be used as a predictor of MTX efficacy than the FPGS or GGH single protein index. This can effectively avoid liver and kidney damage caused by MTX and guides the rational use of drugs in MTX. CONCLUSION: The results prove that there is a positive correlation between the FPGS/GGH and the accumulation of MTXPGS in liver and kidney cells. Summarily, the FPGS/GGH is expected to be a predictor for MTXPGs accumulation and provides an effective method to evaluate the toxicity caused by MTX.


Subject(s)
Methotrexate , gamma-Glutamyl Hydrolase , Humans , Methotrexate/therapeutic use , gamma-Glutamyl Hydrolase/metabolism , Chromatography, Liquid , Tandem Mass Spectrometry , Hepatocytes/metabolism , Kidney/metabolism
3.
Anal Methods ; 15(12): 1546-1552, 2023 03 23.
Article in English | MEDLINE | ID: mdl-36883443

ABSTRACT

Testosterone is a steroid hormone that plays an indispensable role in the normal metabolism of organisms. However, exogenous testosterone, even as low as nmol L-1, will harm the human body due to accumulation. In this study, we developed an unlabeled fluorescent sensor for testosterone based on SYBR Green I. SYBR Green I is a fluorescent dye that can be embedded into the G-quadruplex of the testosterone aptamer T5. The fluorescence quenching effect is utilized to achieve quantitative detection, which occurs by the competition between testosterone and SYBR Green I for the T5 aptamer binding sites. In this work, we optimized the detection conditions to make the fluorescent sensor more sensitive and verify the specificity, linear range, and detection ability in the buffer and real water samples. The sensor's LOD and LOQ values were 0.27 nmol L-1 and 0.91 nmol L-1, respectively, while the detection range was linear from 0.91 nmol L-1 to 2000 nmol L-1. According to the results, the sensor shows high specificity and good performance even in real sample detection such as tap water and river water, providing an alternative method for the quantitative detection of testosterone in the environment, which is more convenient and efficient.


Subject(s)
Oligonucleotides , Testosterone , Humans , Oligonucleotides/chemistry , Benzothiazoles , Testosterone Congeners , Water
4.
Anal Methods ; 13(38): 4442-4451, 2021 10 08.
Article in English | MEDLINE | ID: mdl-34490875

ABSTRACT

As an essential biochemical indicator in the fields of pregnancy and oncology, human chorionic gonadotropin (HCG) can be evaluated using colloidal gold immunochromatographic paper and quantified using a biochemical analyzer based on the principle of the antibody sandwich method. In view of the inaccuracy of the former and the complication of the latter, this study constructed an accurate, sensitive and simple unlabeled biosensor based on peptide aptamer CGGGPPLRINRHILTR for HCG detection. Molecular Operating Environment (MOE) was used to simulate the aptamer and protein docking, and western blot (WB) was used to verify the binding effect and ratio. The peptide aptamer was characterized and was then reduced with tris-(2-carboxyethyl)-phosphine hydrochloride (TCEP). After electrochemical deposition of chloroauric acid on the screen-printed electrode (SPE), the aptamer was self-assembled on the electrode surface under optimal conditions. The active site of the electrode surface was blocked with 6-mercapto-1-hexanol (MCH) and BSA. The electrochemical impedance spectrum (EIS) was used to quantify HCG in the matrix. Showing a good linear relationship in the range of 5-1500 mIU mL-1, with a detection limit of 1 mIU mL-1, the biosensor remained stable at room temperature for 14 days. Because of its small size, stability, sensitivity and accuracy, this biosensor has great potential to become a portable diagnostic device for HCG.


Subject(s)
Aptamers, Nucleotide , Aptamers, Peptide , Biosensing Techniques , Chorionic Gonadotropin , Electrodes , Female , Humans , Pregnancy
SELECTION OF CITATIONS
SEARCH DETAIL