Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Phys Condens Matter ; 33(41)2021 Aug 05.
Article in English | MEDLINE | ID: mdl-33662946

ABSTRACT

Magnonics is a budding research field in nanomagnetism and nanoscience that addresses the use of spin waves (magnons) to transmit, store, and process information. The rapid advancements of this field during last one decade in terms of upsurge in research papers, review articles, citations, proposals of devices as well as introduction of new sub-topics prompted us to present the first roadmap on magnonics. This is a collection of 22 sections written by leading experts in this field who review and discuss the current status besides presenting their vision of future perspectives. Today, the principal challenges in applied magnonics are the excitation of sub-100 nm wavelength magnons, their manipulation on the nanoscale and the creation of sub-micrometre devices using low-Gilbert damping magnetic materials and its interconnections to standard electronics. To this end, magnonics offers lower energy consumption, easier integrability and compatibility with CMOS structure, reprogrammability, shorter wavelength, smaller device features, anisotropic properties, negative group velocity, non-reciprocity and efficient tunability by various external stimuli to name a few. Hence, despite being a young research field, magnonics has come a long way since its early inception. This roadmap asserts a milestone for future emerging research directions in magnonics, and hopefully, it will inspire a series of exciting new articles on the same topic in the coming years.

2.
Article in English | MEDLINE | ID: mdl-31093520

ABSTRACT

We investigate the use of Cu1-x Zn x Fe2O4 ferrites (0.60 < x < 0.76) as potential sensors for magnetic- resonance-imaging thermometry. Samples are prepared by a standard ceramic technique. Their structural and magnetic properties are determined using x-ray diffraction, scanning electron microscopy, super-conducting quantum-interference device magnetometry, and Mossbauer and 3-T nuclear-magnetic-resonance spectroscopies. We use the mass magnetization of powdered ferrites and transverse relaxivity r*2 of water protons in Ringer's-solution-based agar gels with embedded micron-sized particles to determine the best composition for magnetic-resonance-imaging (MRI) temperature sensors in the (280-323)-K range. A preclinical 3-T MRI scanner is employed to acquire T*2 weighted temperature-dependent images. The brightness of the MRI images is cross-correlated with the temperature of the phantoms, which allows for a temperature determination with approximately 1°C accuracy. We determine that the composition of 0.65 < x < 0.70 is the most suitable for MRI thermometry near human body temperature.

3.
Nat Commun ; 7: 12415, 2016 08 09.
Article in English | MEDLINE | ID: mdl-27503610

ABSTRACT

Magnetic resonance imaging is an important technique for identifying different types of tissues in a body or spatial information about composite materials. Because temperature is a fundamental parameter reflecting the biological status of the body and individual tissues, it would be helpful to have temperature maps superimposed on spatial maps. Here we show that small ferromagnetic particles with a strong temperature-dependent magnetization, can be used to produce temperature-dependent images in magnetic resonance imaging with an accuracy of about 1 °C. This technique, when further developed, could be used to identify inflammation or tumours, or to obtain spatial maps of temperature in various medical interventional procedures such as hyperthermia and thermal ablation. This method could also be used to determine temperature profiles inside nonmetallic composite materials.

4.
Phys Rev Lett ; 96(1): 017201, 2006 Jan 13.
Article in English | MEDLINE | ID: mdl-16486507

ABSTRACT

We investigate stripe domain formation in nanometer sized Co bars. The magnetic equilibrium states and the magnetic spin wave frequencies are obtained from micromagnetic-like simulations. We find that the lowest frequency standing-wave mode has the same spatial structure as the stripe domains at remanence and it goes soft at the field where the stripe domains emerge. We show, therefore, that the final domain structure at remanence, which is not the configuration with lowest energy, is predicted from a high-field analysis of the frequencies of the standing spin waves.

5.
Phys Rev Lett ; 96(4): 047401, 2006 Feb 03.
Article in English | MEDLINE | ID: mdl-16486893

ABSTRACT

Inelastic light scattering from an array of Permalloy particles driven by a microwave magnetic field is shown to be a coherent phenomenon in which the scattered radiation is observed only at diffraction angles corresponding to the reciprocal lattice of the array. The results are explained in terms of the phase coherence of the inelastically scattered light by each of the particles.

SELECTION OF CITATIONS
SEARCH DETAIL
...