Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
2.
J Infect Dis ; 228(8): 1066-1070, 2023 10 18.
Article in English | MEDLINE | ID: mdl-37353225

ABSTRACT

We evaluated the performance of rapid antigen (RAg) and antibody (RAb) microfluidic diagnostics with serial sampling of 71 participants at 6 visits over 2 months following severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. Rapid tests showed strong agreement with laboratory references (κAg = 81.0%; κAb = 87.8%). RAg showed substantial concordance to both virus growth in culture and PCR positivity 0-5 days since symptom onset (κAg-culture = 60.1% and κAg-PCR = 87.1%). PCR concordance to virus growth in culture was similar (κPCR-culture = 70.0%), although agreement between RAg and culture was better overall (κAg-culture = 45.5% vs κPCR-culture = 10.0%). Rapid antigen and antibody testing by microfluidic immunofluorescence platform are highly accurate for characterization of acute infection.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , COVID-19/diagnosis , COVID-19 Testing , Clinical Laboratory Techniques , Microfluidics , Sensitivity and Specificity , Antibodies , Polymerase Chain Reaction
3.
Microbiol Spectr ; 11(3): e0373122, 2023 06 15.
Article in English | MEDLINE | ID: mdl-37166329

ABSTRACT

Rapid diagnostic tests (RDTs) that detect antigen indicative of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection can help in making quick health care decisions and regularly monitoring groups at risk of infection. With many RDT products entering the market, it is important to rapidly evaluate their relative performance. Comparison of clinical evaluation study results is challenged by protocol design variations and study populations. Laboratory assays were developed to quantify nucleocapsid (N) and spike (S) SARS-CoV-2 antigens. Quantification of the two antigens in nasal eluates confirmed higher abundance of N than S antigen. The median concentration of N antigen was 10 times greater than S per genome equivalent. The N antigen assay was used in combination with quantitative reverse transcription (RT)-PCR to qualify a panel composed of recombinant antigens, inactivated virus, and clinical specimen pools. This benchmarking panel was applied to evaluate the analytical performance of the SD Biosensor Standard Q COVID-19 antigen (Ag) test, Abbott Panbio COVID-19 Ag rapid test, Abbott BinaxNOW COVID-19 Ag test, and the LumiraDx SARS-CoV-2 Ag test. The four tests displayed different sensitivities toward the different panel members, but all performed best with the clinical specimen pool. The concentration for a 90% probability of detection across the four tests ranged from 21 to 102 pg/mL of N antigen in the extracted sample. Benchmarking panels provide a quick way to verify the baseline performance of a diagnostic and enable direct comparisons between diagnostic tests. IMPORTANCE This study reports the results for severe acute respiratory syndrome coronavirus-2 (SARS-COV-2) nucleocapsid (N) and spike (S) antigen quantification assays and their performance against clinical reverse transcription (RT)-PCR results, thus describing an open-access quantification method for two important SARS-CoV-2 protein analytes. Characterized N antigen panels were used to evaluate the limits of detection of four different rapid tests for SARS-CoV-2 against multiple sources of nucleocapsid antigen, demonstrating proof-of-concept materials and methodology to evaluate SARS-CoV-2 rapid antigen detection tests. Quantification of N antigen was used to characterize the relationship between viral count and antigen concentration among clinical samples and panel members of both clinical sample and viral culture origin. This contributes to a deeper understanding of protein antigen and molecular analytes and presents analytical methods complementary to clinical evaluation for characterizing the performance of both laboratory-based and point-of-care rapid diagnostics for SARS-CoV-2.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , SARS-CoV-2 , Indicators and Reagents , Benchmarking , Diagnostic Tests, Routine , COVID-19 Testing
4.
J Clin Virol ; 161: 105420, 2023 04.
Article in English | MEDLINE | ID: mdl-36913789

ABSTRACT

BACKGROUND: Guidelines for SARS-CoV-2 have relied on limited data on duration of viral infectiousness and correlation with COVID-19 symptoms and diagnostic testing. METHODS: We enrolled ambulatory adults with acute SARS-CoV-2 infection and performed serial measurements of COVID-19 symptoms, nasal swab viral RNA, nucleocapsid (N) and spike (S) antigens, and replication-competent SARS-CoV-2 by viral growth in culture. We determined average time from symptom onset to a first negative test result and estimated risk of infectiousness, as defined by positive viral growth in culture. RESULTS: Among 95 adults, median [interquartile range] time from symptom onset to first negative test result was 9 [5] days, 13 [6] days, 11 [4] days, and >19 days for S antigen, N antigen, culture growth, and viral RNA by RT-PCR, respectively. Beyond two weeks, virus growth and N antigen titers were rarely positive, while viral RNA remained detectable among half (26/51) of participants tested 21-30 days after symptom onset. Between 6-10 days from symptom onset, N antigen was strongly associated with culture positivity (relative risk=7.61, 95% CI: 3.01-19.22), whereas neither viral RNA nor symptoms were associated with culture positivity. During the 14 days following symptom onset, the presence of N antigen remained strongly associated (adjusted relative risk=7.66, 95% CI: 3.96-14.82) with culture positivity, regardless of COVID-19 symptoms. CONCLUSIONS: Most adults have replication-competent SARS-CoV-2 for 10-14 after symptom onset. N antigen testing is a strong predictor of viral infectiousness and may be a more suitable biomarker, rather than absence of symptoms or viral RNA, to discontinue isolation within two weeks from symptom onset.


Subject(s)
COVID-19 , Adult , Humans , COVID-19/diagnosis , SARS-CoV-2 , Longitudinal Studies , Diagnostic Techniques and Procedures , RNA, Viral , COVID-19 Testing
5.
PLoS One ; 17(9): e0274415, 2022.
Article in English | MEDLINE | ID: mdl-36178936

ABSTRACT

Lipoarabinomannan (LAM), a component of the Mycobacterium tuberculosis (MTB) cell wall, is detectable in the urine of MTB infected patients with active tuberculosis (TB). LAM-specific antibodies (Igs) have been developed by a variety of traditional and recombinant methods for potential use in a rapid diagnostic test (RDT). We evaluated the analytical performance of the TB LAM Igs to identify pairs that offer superior performance over existing urine LAM tests. We assessed 25 new and 4 existing Igs in a matrixed format using a multiplex electrochemiluminescence-based liquid immunoassay. A total of 841 paired Ig combinations were challenged with in vitro cultured LAM (cLAM) derived from MTB strains representing diverse phylogenetic lineages, alongside urinary LAM (uLAM) from the urine of adults with active pulmonary TB. Analytical sensitivity of down-selected Ig pairs was determined using MTB Aoyama-B cLAM, while diagnostic accuracy was determined using clinical samples. When testing cLAM, the reactivity of Ig pairs was similar across MTB lineages 1-4 but lineage 5:6 had significantly more reactivity among Ig pairs. Overall, 41 Ig pairs had a strong binding affinity to cLAM, as compared to the reference pair of S4-20/A194-01, and 28 Ig pairs therein exhibited a strong affinity for both cLAM and uLAM. Retrospective testing on clinical urine specimens demonstrated varying sensitivities (12-80%) and specificities (14-100%). The five top pairs had a similar analytical limit of detection to the reference pair but in four instances, the sensitivity and specificity with clinical uLAM samples was poor. Overall, epitopes presented by uLAM are different from cLAM, which may affect antibody performance when testing uLAM in patient samples. Several new Ig pairs had similar ranges of high sensitivity to cLAM but overall, there were no new candidate Ig pairs identified in this round of screening with increased performance with uLAM as compared to an existing optimal pair.


Subject(s)
HIV Infections , Mycobacterium tuberculosis , Tuberculosis, Lymph Node , Adult , Diagnostic Tests, Routine/methods , Epitopes , HIV Infections/diagnosis , Humans , Lipopolysaccharides , Phylogeny , Retrospective Studies , Sensitivity and Specificity
6.
Int J Infect Dis ; 117: 287-294, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35149246

ABSTRACT

OBJECTIVES: This study assesses and compares the performance of different swab types and specimen collection sites for SARS-CoV-2 testing, to reference standard real-time reverse transcriptase-polymerase chain reaction (RT-PCR) and viral culture. METHODS: Symptomatic adults with COVID-19 who visited routine COVID-19 testing sites used spun polyester and FLOQSwabs to self-collect specimens from the anterior nares and tongue. We evaluated the self-collected specimen from anterior nares and tongue swabs for the nucleocapsid (N) or spike (S) antigen of SARS-CoV-2 by RT-PCR and then compared these results with results from RT-PCR and viral cultures from nurse-collected nasopharyngeal swabs. RESULTS: Diagnostic sensitivity was highest for RT-PCR testing conducted using specimens from the anterior nares collected on FLOQSwabs (84%; 95% CI 68-94%) and spun polyester swabs (82%; 95% CI 66-92%), compared to RT-PCR tests conducted using specimens from nasopharyngeal swabs. Relative to viral culture from nasopharyngeal swabs, diagnostic sensitivities were higher for RT-PCR and antigen testing of anterior nares swabs (91-100%) than that of tongue swabs (18-81%). Antigen testing of anterior nares swabs had higher sensitivities against viral culture (91%) than against nasopharyngeal RT-PCR (38-70%). All investigational tests had high specificity compared with nasopharyngeal RT-PCR. Spun polyester swabs are equally effective as FLOQSwabs for anterior nasal RT-PCR testing. CONCLUSIONS: We found that anterior nares specimens were more sensitive than tongue swab specimens or antigen testing for detecting SARS-CoV-2 by RT-PCR. Thus, self-collected anterior nares specimens may represent an alternative method for diagnostic SARS-CoV-2 testing in some settings.


Subject(s)
COVID-19 , Nucleic Acids , Adult , COVID-19/diagnosis , COVID-19 Testing , Humans , Nasopharynx , Nucleocapsid/genetics , Polymerase Chain Reaction , SARS-CoV-2/genetics , Sensitivity and Specificity , Specimen Handling/methods , Tongue
7.
Anal Bioanal Chem ; 414(8): 2607-2618, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35091761

ABSTRACT

The lateral flow assay (LFA) is one of the most popular technologies on the point-of-care diagnostics market due to its low cost and ease of use, with applications ranging from pregnancy to environmental toxins to infectious disease. While the use of these tests is relatively straightforward, significant development time and effort are required to create tests that are both sensitive and specific. Workflows to guide the LFA development process exist but moving from target selection to an LFA that is ready for field testing can be labor intensive, resource heavy, and time consuming. To reduce the cost and the duration of the LFA development process, we introduce a novel development platform centered on the flexibility, speed, and throughput of an automated robotic liquid handling system. The system comprises LFA-specific hardware and software that enable large optimization experiments with discrete and continuous variables such as antibody pair selection or reagent concentration. Initial validation of the platform was demonstrated during development of a malaria LFA but was readily expanded to encompass development of SARS-CoV-2 and Mycobacterium tuberculosis LFAs. The validity of the platform, where optimization experiments are run directly on LFAs rather than in solution, was based on a direct comparison between the robotic system and a more traditional ELISA-like method. By minimizing hands-on time, maximizing experiment size, and enabling improved reproducibility, the robotic system improved the quality and quantity of LFA assay development efforts.


Subject(s)
COVID-19/diagnosis , Immunoassay/instrumentation , Malaria/diagnosis , Point-of-Care Testing , Tuberculosis/diagnosis , COVID-19 Serological Testing/economics , COVID-19 Serological Testing/instrumentation , Equipment Design , Humans , Immunoassay/economics , Mycobacterium tuberculosis/isolation & purification , Plasmodium/isolation & purification , Point-of-Care Testing/economics , Reproducibility of Results , SARS-CoV-2/isolation & purification , Sensitivity and Specificity , Time Factors
8.
PLoS Negl Trop Dis ; 15(9): e0009782, 2021 09.
Article in English | MEDLINE | ID: mdl-34516554

ABSTRACT

BACKGROUND: Soil-transmitted helminths (STHs) are parasitic nematodes that inhabit the human intestine. They affect more than 1.5 billion people worldwide, causing physical and cognitive impairment in children. The global strategy to control STH infection includes periodic mass drug administration (MDA) based on the results of diagnostic testing among populations at risk, but the current microscopy method for detecting infection has diminished sensitivity as the intensity of infection decreases. Thus, improved diagnostic tools are needed to support decision-making for STH control programs. METHODOLOGY: We developed a nucleic acid amplification test based on recombinase polymerase amplification (RPA) technology to detect STH in stool. We designed primers and probes for each of the four STH species, optimized the assay, and then verified its performance using clinical stool samples. PRINCIPAL FINDINGS: Each RPA assay was as sensitive as a real-time polymerase chain reaction (PCR) assay in detecting copies of cloned target DNA sequences. The RPA assay amplified the target in DNA extracted from human stool samples that were positive for STH based on the Kato-Katz method, with no cross-reactivity of the non-target genomic DNA. When tested with clinical stool samples from patients with infections of light, moderate, and heavy intensity, the RPA assays demonstrated performance comparable to that of real-time PCR, with better results than Kato-Katz. This new rapid, sensitive and field-deployable method for detecting STH infections can help STH control programs achieve their goals. CONCLUSIONS: Semi-quantitation of target by RPA assay is possible and is comparable to real-time PCR. With proper instrumentation, RPA assays can provide robust, semi-quantification of STH DNA targets as an alternative field-deployable indicator to counts of helminth eggs for assessing infection intensity.


Subject(s)
Feces/parasitology , Helminthiasis/diagnosis , Nucleic Acid Amplification Techniques/standards , Recombinases/metabolism , Soil/parasitology , DNA, Helminth/genetics , Helminthiasis/parasitology , Helminthiasis/transmission , Humans , Recombinases/chemistry , Reproducibility of Results , Sensitivity and Specificity
9.
ACS Omega ; 6(31): 20139-20148, 2021 Aug 10.
Article in English | MEDLINE | ID: mdl-34373846

ABSTRACT

Severe acute respiratory coronavirus-2 (SARS-CoV-2) is a novel viral pathogen and therefore a challenge to accurately diagnose infection. Asymptomatic cases are common and so it is difficult to accurately identify infected cases to support surveillance and case detection. Diagnostic test developers are working to meet the global demand for accurate and rapid diagnostic tests to support disease management. However, the focus of many of these has been on molecular diagnostic tests, and more recently serologic tests, for use in primarily high-income countries. Low- and middle-income countries typically have very limited access to molecular diagnostic testing due to fewer resources. Serologic testing is an inappropriate surrogate as the early stages of infection are not detected and misdiagnosis will promote continued transmission. Detection of infection via direct antigen testing may allow for earlier diagnosis provided such a method is sensitive. Leading SARS-CoV-2 biomarkers include spike protein, nucleocapsid protein, envelope protein, and membrane protein. This research focuses on antibodies to SARS-CoV-2 spike protein due to the number of monoclonal antibodies that have been developed for therapeutic research but also have potential diagnostic value. In this study, we assessed the performance of antibodies to the spike glycoprotein, acquired from both commercial and private groups in multiplexed liquid immunoassays, with concurrent testing via a half-strip lateral flow assays (LFA) to indicate antibodies with potential in LFA development. These processes allow for the selection of pairs of high-affinity antispike antibodies that are suitable for liquid immunoassays and LFA, some of which with sensitivity into the low picogram range with the liquid immunoassay formats with no cross-reactivity to other coronavirus S antigens. Discrepancies in optimal ranking were observed with the top pairs used in the liquid and LFA formats. These findings can support the development of SARS-CoV-2 LFAs and diagnostic tools.

10.
PLoS Negl Trop Dis ; 14(9): e0008711, 2020 09.
Article in English | MEDLINE | ID: mdl-32997666

ABSTRACT

Environmental enteric dysfunction (EED) is an intestinal disorder common among children in low-resource settings and is associated with increased risk of growth stunting, cognitive deficits, and reduced oral vaccine immunogenicity. The Micronutrient and EED Assessment Tool (MEEDAT) is a multiplexed immunoassay that measures biomarkers previously associated with child growth faltering and/or oral vaccine immunogenicity: intestinal fatty acid-binding protein (I-FABP), soluble CD14 (sCD14), insulin-like growth factor 1 (IGF-1), and fibroblast growth factor 21 (FGF21). MEEDAT also measures systemic inflammation (α1-acid glycoprotein, C-reactive protein), ferritin, soluble transferrin receptor, retinol binding protein 4, thyroglobulin, and Plasmodium falciparum antigenemia (histidine-rich protein 2). The performance of MEEDAT was compared with commercially available enzyme-linked immunosorbent assays (ELISAs) using 300 specimens from Malian infant clinical trial participants. Regression methods were used to test if MEEDAT biomarkers were associated with seroconversion to meningococcal A conjugate vaccine (MenAV), yellow fever vaccine (YFV), and pentavalent rotavirus vaccine (PRV) after 28 days, or with growth faltering over 12 weeks. The Pearson correlations between the MEEDAT and ELISA results were 0.97, 0.86, 0.80, and 0.97 for serum I-FABP, sCD14, IGF-1, and FGF21, respectively. There were significant associations between I-FABP concentration and the probability of PRV IgG seroconversion and between IGF-1 concentration and the probability of YFV seroconversion. In multivariable models neither association remained significant, however there was a significant negative association between AGP concentration and YFV seroconversion. GLP-2 and sCD14 concentrations were significantly negatively associated with 12-week change in weight-for-age z-score and weight-for-height z-score in multivariable models. MEEDAT performed well in comparison to commercially-available ELISAs for the measurement of four analytes for EED and growth hormone resistance. Adoption of MEEDAT in low-resource settings could help accelerate the identification of interventions that prevent or treat child stunting and interventions that boost the immunogenicity of child vaccinations.


Subject(s)
Immunogenicity, Vaccine/immunology , Intestinal Diseases/immunology , Micronutrients/immunology , Vaccines/immunology , Yellow Fever Vaccine/immunology , Yellow Fever/immunology , Yellow Fever/prevention & control , Biomarkers/blood , Double-Blind Method , Enzyme-Linked Immunosorbent Assay , Fatty Acid-Binding Proteins , Female , Ferritins/blood , Fibroblast Growth Factors/blood , Humans , Infant , Inflammation , Insulin-Like Growth Factor I/metabolism , Intestine, Small , Lipopolysaccharide Receptors , Male , Mali , Retinol-Binding Proteins, Plasma , Risk Factors , Vaccination
11.
PLoS Negl Trop Dis ; 14(6): e0008231, 2020 06.
Article in English | MEDLINE | ID: mdl-32544158

ABSTRACT

BACKGROUND: Nucleic acid amplification tests (NAATs) are increasingly being used as diagnostic tools for soil-transmitted helminths (STHs; Ascaris lumbricoides, Trichuris trichiura, Necator americanus, Ancylostoma duodenale and A. ceylanicum), Strongyloides stercoralis and Schistosoma in human stool. Currently, there is a large diversity of NAATs being applied, but an external quality assessment scheme (EQAS) for these diagnostics is lacking. An EQAS involves a blinded process where test results reported by a laboratory are compared to those reported by reference or expert laboratories, allowing for an objective assessment of the diagnostic performance of a laboratory. In the current study, we piloted an international EQAS for these helminths (i) to investigate the feasibility of designing and delivering an EQAS; (ii) to assess the diagnostic performance of laboratories; and (iii) to gain insights into the different NAAT protocols used. METHODS AND PRINCIPAL FINDINGS: A panel of twelve stool samples and eight DNA samples was validated by six expert laboratories for the presence of six helminths (Ascaris, Trichuris, N. americanus, Ancylostoma, Strongyloides and Schistosoma). Subsequently this panel was sent to 15 globally dispersed laboratories. We found a high degree of diversity among the different DNA extraction and NAAT protocols. Although most laboratories performed well, we could clearly identify the laboratories that were poorly performing. CONCLUSIONS/SIGNIFICANCE: We showed the technical feasibility of an international EQAS for the NAAT of STHs, Strongyloides and Schistosoma. In addition, we documented that there are clear benefits for participating laboratories, as they can confirm and/or improve the diagnostic performance of their NAATs. Further research should aim to identify factors that explain poor performance of NAATs.


Subject(s)
Helminthiasis/diagnosis , Laboratory Proficiency Testing/organization & administration , Molecular Diagnostic Techniques/methods , Nucleic Acid Amplification Techniques/methods , Adolescent , Animals , Child , Feces/parasitology , Female , Helminths/classification , Helminths/genetics , Helminths/isolation & purification , Humans , Male , Molecular Diagnostic Techniques/standards , Nucleic Acid Amplification Techniques/standards , Pilot Projects
12.
PLoS One ; 14(4): e0215756, 2019.
Article in English | MEDLINE | ID: mdl-31009510

ABSTRACT

Nucleic acid amplification technologies (NAATs) are high-performance tools for rapidly and accurately detecting infectious agents. They are widely used in high-income countries to diagnose disease and improve patient care. The complexities associated with test methods, reagents, equipment, quality control and assurance require dedicated laboratories with trained staff, which can exclude their use in low-resource and decentralized healthcare settings. For certain diseases, fully integrated NAAT devices and assays are available for use in environmentally-controlled clinics or emergency rooms where relatively untrained staff can perform testing. However, decentralized settings in many low- and middle-income countries with large burdens of infectious disease are challenged by extreme environments, poor infrastructure, few trained staff and limited financial resources. Therefore, there is an urgent need for low-cost, integrated NAAT tools specifically designed for use in low-resource settings (LRS). Two essential components of integrated NAAT tools are: 1) efficient nucleic acid extraction technologies for diverse and complex sample types; and 2) robust and sensitive nucleic acid amplification and detection technologies. In prior work we reported the performance and workflow capacity for the nucleic acid extraction component. In the current study we evaluated performance of eight novel nucleic acid amplification and detection technologies from seven developers using blinded panels of RNA and/or DNA from three pathogens to assess both diagnostic accuracy and suitability as an essential component for low-cost NAAT in LRS. In this exercise, we noted significant differences in performance among these technologies and identified those most promising for potential further development.


Subject(s)
Communicable Diseases/diagnosis , Nucleic Acid Amplification Techniques/methods , Nucleic Acids/genetics , Point-of-Care Systems/economics , Chlamydia/genetics , Communicable Diseases/microbiology , Communicable Diseases/virology , Cost-Benefit Analysis , HIV-1/genetics , Health Resources/economics , Humans , Neisseria gonorrhoeae/genetics , Nucleic Acid Amplification Techniques/instrumentation , Reproducibility of Results , Zika Virus/genetics
13.
PLoS Negl Trop Dis ; 10(12): e0004985, 2016 12.
Article in English | MEDLINE | ID: mdl-28005900

ABSTRACT

Global efforts to address schistosomiasis and soil-transmitted helminthiases (STH) include deworming programs for school-aged children that are made possible by large-scale drug donations. Decisions on these mass drug administration (MDA) programs currently rely on microscopic examination of clinical specimens to determine the presence of parasite eggs. However, microscopy-based methods are not sensitive to the low-intensity infections that characterize populations that have undergone MDA. Thus, there has been increasing recognition within the schistosomiasis and STH communities of the need for improved diagnostic tools to support late-stage control program decisions, such as when to stop or reduce MDA. Failure to adequately address the need for new diagnostics could jeopardize achievement of the 2020 London Declaration goals. In this report, we assess diagnostic needs and landscape potential solutions and determine appropriate strategies to improve diagnostic testing to support control and elimination programs. Based upon literature reviews and previous input from experts in the schistosomiasis and STH communities, we prioritized two diagnostic use cases for further exploration: to inform MDA-stopping decisions and post-MDA surveillance. To this end, PATH has refined target product profiles (TPPs) for schistosomiasis and STH diagnostics that are applicable to these use cases. We evaluated the limitations of current diagnostic methods with regards to these use cases and identified candidate biomarkers and diagnostics with potential application as new tools. Based on this analysis, there is a need to develop antigen-detecting rapid diagnostic tests (RDTs) with simplified, field-deployable sample preparation for schistosomiasis. Additionally, there is a need for diagnostic tests that are more sensitive than the current methods for STH, which may include either a field-deployable molecular test or a simple, low-cost, rapid antigen-detecting test.


Subject(s)
Diagnostic Tests, Routine/methods , Diagnostic Tests, Routine/standards , Helminthiasis/diagnosis , Helminthiasis/parasitology , Medical Laboratory Personnel , Schistosomiasis/diagnosis , Schistosomiasis/parasitology , Soil/parasitology , Biomarkers , Child , Diagnostic Tests, Routine/economics , Diagnostic Tests, Routine/trends , Feces , Female , Helminthiasis/epidemiology , Helminthiasis/transmission , Humans , Infection Control/economics , Infection Control/methods , Infection Control/standards , Infection Control/statistics & numerical data , London , Male , Parasite Load , Prevalence , Preventive Health Services/methods , Preventive Health Services/statistics & numerical data , Schistosomiasis/epidemiology , Schistosomiasis/prevention & control
14.
J Virol Methods ; 171(1): 176-82, 2011 Jan.
Article in English | MEDLINE | ID: mdl-21029747

ABSTRACT

In view of the need to develop a simple and rapid method to screen for antiviral therapeutic agents, a fluorescence resonance energy transfer (FRET)-based reporter system consisting of engineered mammalian cells expressing a cyan fluorescent protein-yellow fluorescent protein (CFP-YFP) pair linked by a short peptide containing the cleavage site of viral protease 2A (2A(pro)) was developed. By detecting the 2A(pro) produced early during the virus infection cycle, the CFP-YFP pair effectively identifies infectious coxsackievirus B3 (CVB3), a picornavirus that causes viral myocarditis in humans. The reporter system was used to screen a library of 2000 drugs and natural products for potential antiviral compounds. The reporter cells were treated with the test compounds, challenged with CVB3, and then examined using a fluorometer at 24h post-infection. Sixty-four compounds, mostly therapeutic drugs, antimicrobial compounds and compounds with unknown functions, caused at least 50% inhibition of 2A(pro) activity. Three known antiviral compounds, cosmosiin, ribavirin and baicalein, were also identified in the screening. The developed method is an effective strategy for rapid screening, and identifies compounds that inhibit CVB3 2A(pro). This method should be a valuable aid in the antiviral drug discovery effort.


Subject(s)
Antiviral Agents/pharmacology , Drug Evaluation, Preclinical/methods , Enterovirus B, Human/drug effects , Fluorescence Resonance Energy Transfer , Fluorometry/methods , Animals , Bacterial Proteins/genetics , Bacterial Proteins/metabolism , Cell Line , Genes, Reporter , Green Fluorescent Proteins/genetics , Green Fluorescent Proteins/metabolism , Humans , Hydrolysis , Luminescent Proteins/genetics , Luminescent Proteins/metabolism , Peptide Hydrolases/metabolism , Recombinant Fusion Proteins/genetics , Recombinant Fusion Proteins/metabolism , Viral Proteins/metabolism
15.
Appl Environ Microbiol ; 76(2): 584-8, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19933336

ABSTRACT

The rapid and effective detection of virus infection is critical for clinical management and prevention of disease spread during an outbreak. Several methods have been developed for this purpose, of which classical serological and viral nucleic acid detection are the most common. We describe an alternative approach that utilizes engineered cells expressing fluorescent proteins undergoing fluorescence resonance energy transfer (FRET) upon cleavage by the viral 2A protease (2A(pro)) as an indication of infection. Quantification of the infectious-virus titers was resolved by using flow cytometry, and utility was demonstrated for the detection of poliovirus 1 (PV1) infection. Engineered buffalo green monkey kidney (BGMK) cells expressing the cyan fluorescent protein (CFP)-yellow fluorescent protein (YFP) substrate linked by a cleavage recognition site for PV1 2A(pro) were infected with different titers of PV1. After incubation at various time points, cells were harvested, washed, and subjected to flow cytometry analysis. The number of infected cells was determined by counting the number of cells with an increased CFP-to-YFP ratio. As early as 5 h postinfection, a significant number of infected cells (3%) was detected by flow cytometry, and cells infected with only 1 PFU were detected after 12 h postinfection. When applied to an environmental water sample spiked with PV1, the flow cytometry-based assay provided a level of sensitivity similar to that of the plaque assay for detecting and quantifying infectious virus particles. This approach, therefore, is more rapid than plaque assays and can be used to detect other viruses that frequently do not form clear plaques on cell cultures.


Subject(s)
Flow Cytometry/methods , Fluorescence Resonance Energy Transfer/methods , Poliovirus/isolation & purification , Animals , Cell Line , Chlorocebus aethiops , Water Microbiology
SELECTION OF CITATIONS
SEARCH DETAIL
...