Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Braz Oral Res ; 25(6): 492-9, 2011.
Article in English | MEDLINE | ID: mdl-22147228

ABSTRACT

Cordless retraction paste material for gingival retraction in implant dentistry has recently become of interest to the clinician. However, few studies have been conducted on the use of retraction pastes and their possible interaction with implant surfaces. This in vitro study evaluated the effect of a cordless retraction paste material, Expasyl® (Acteon), on TiUnite® (Nobel Biocare) implant surfaces. Three areas of the fixtures were evaluated before and after contact with the retraction paste using scanning electron microscopy to evaluate changes in surface topography and energy-dispersive spectroscopy to identify any surface chemistry modifications. Alteration of the initial surface after exposure to Expasyl® was identified, with the implant collar showing the most changes.


Subject(s)
Dental Implants , Dental Impression Materials/chemistry , Dental Impression Technique/instrumentation , Gingival Retraction Techniques/instrumentation , Analysis of Variance , Humans , Materials Testing , Microscopy, Electron, Scanning , Spectrometry, X-Ray Emission , Surface Properties , Time Factors , Titanium/chemistry
2.
Braz. oral res ; 25(6): 492-499, Nov.-Dec. 2011. ilus, graf
Article in English | LILACS | ID: lil-608016

ABSTRACT

Cordless retraction paste material for gingival retraction in implant dentistry has recently become of interest to the clinician. However, few studies have been conducted on the use of retraction pastes and their possible interaction with implant surfaces. This in vitro study evaluated the effect of a cordless retraction paste material, Expasyl® (Acteon), on TiUnite® (Nobel Biocare) implant surfaces. Three areas of the fixtures were evaluated before and after contact with the retraction paste using scanning electron microscopy to evaluate changes in surface topography and energy-dispersive spectroscopy to identify any surface chemistry modifications. Alteration of the initial surface after exposure to Expasyl® was identified, with the implant collar showing the most changes.


Subject(s)
Humans , Dental Implants , Dental Impression Materials/chemistry , Dental Impression Technique/instrumentation , Gingival Retraction Techniques/instrumentation , Analysis of Variance , Materials Testing , Microscopy, Electron, Scanning , Spectrometry, X-Ray Emission , Surface Properties , Time Factors , Titanium/chemistry
3.
Rev. paul. pediatr ; 27(2): 204-210, jun. 2009.
Article in Portuguese | LILACS | ID: lil-518195

ABSTRACT

OBJETIVO:Descrever peculiaridades da circulação mesentérica neonatal e caracterizar fatores de suscetibilidade ao desenvolvimento de doenças gastrintestinais e alterações do fluxo sanguíneo da artéria mesentérica superior por meio da dopplerfluxometria. FONTES DE DADOS: Livros-textos e publicações indexadas no Medline e SciELO nos últimos 20 anos, utilizando-se as palavras chaves: "mesenteric artery", "superior mesenteric artery", "newborn intestinal circulation", "necrotizing enterocolitis", "doppler flow velocimetry". SÍNTESE DOS DADOS: Alterações do fluxo sanguíneo mesentérico são um dos fatores predisponentes da enterocolite necrosante, doença neonatal de alta morbimortalidade que acomete principalmente prematuros. A circulação mesentérica é peculiar no período neonatal tanto em relação ao seu estado basal, quanto à sua resposta frente a estímulos fisiológicos. Variações da irrigação mesentérica podem ser inerentes à própria fase de desenvolvimento vascular intestinal do recém-nascido pré-termo, com possíveis agravos de fatores perinatais como: insuficiência placentária, asfixia, infecção, cateterismo umbilical, drogas (indometacina e cafeína), fototerapia, alimentação artificial e progressão rápida da dieta. A dopplerfluxometria permite o estudo da irrigação de órgãos-alvo e pode quantificar o fluxo sanguíneo, a resistência vascular e predizer situações de risco para doenças do trato gastrintestinal no período neonatal. CONCLUSÕES: O recém-nascido apresenta peculiaridades de irrigação sanguínea gastrintestinal. A dopplerfluxometria da artéria mesentérica superior é um método não invasivo que determina as condições circulatórias no território intestinal.


OBJECTIVE:To describe peculiarities of the neonatal mesenteric circulation and to characterize the susceptibility factors to the development of gastrointestinal illnesses and alterations of the superior mesenteric artery flow by the Doppler ultrasound method. DATA SOURCES: Textbooks and publications listed in Medline and SciELO from the last 20 years were searched using the key-words: "mesenteric artery", "intestinal superior mesenteric artery", "newborn circulation", "necrotizing enterocolitis", and "Doppler flow velocimetry". DATA SYNTHESIS: Alterations in the mesenteric flow are predisposing factors for necrotizing enterocolitis, which is a neonatal illness with high morbidity and mortality that occurs mainly in premature infants. The mesenteric circulation is peculiar at the neonatal period regarding its baseline status as well as its response from physiological stimulation. Mesenteric irrigation varies according to the proper phase of intestinal vascular development. Mesenteric irrigation can be damaged by perinatal factors, such as placental insufficiency, asphyxia, infection, umbilical catheters, drugs (indomethacin and caffeine), phototherapy, artificial feeding and fast diet progression. Doppler flow velocimetry allows the study of gut irrigations and may quantify blood flow and vascular resistance. The exam can predict risk situations for gastrointestinal illnesses during the neonatal period. CONCLUSIONS: The newborn infant presents peculiarities on gastrointestinal blood circulation. Superior mesenteric artery Doppler ultrasound provides non-invasive measures of the intestinal circulatory conditions.


Subject(s)
Humans , Infant, Newborn , Mesenteric Artery, Superior , Splanchnic Circulation , Enterocolitis, Necrotizing
4.
Rev Hosp Clin Fac Med Sao Paulo ; 59(3): 104-12, 2004 Jun.
Article in English | MEDLINE | ID: mdl-15286829

ABSTRACT

OBJECTIVE: To evaluate the effects of 2 different doses of exogenous surfactant on pulmonary mechanics and on the regularity of pulmonary parenchyma inflation in newborn rabbits. METHOD: Newborn rabbits were submitted to tracheostomy and randomized into 4 study groups: the Control group did not receive any material inside the trachea; the MEC group was instilled with meconium, without surfactant treatment; the S100 and S200 groups were instilled with meconium and were treated with 100 and 200 mg/kg of exogenous surfactant (produced by Instituto Butantan) respectively. Animals from the 4 groups were mechanically ventilated during a 25-minute period. Dynamic compliance, ventilatory pressure, tidal volume, and maximum lung volume (P-V curve) were evaluated. Histological analysis was conducted using the mean linear intercept (Lm), and the lung tissue distortion index (SDI) was derived from the standard deviation of the means of the Lm. One-way analysis of variance was used with a = 0.05. RESULTS: After 25 minutes of ventilation, dynamic compliance (mL/cm H2O.kg) was 0.87 +/- 0.07 (Control); 0.49 +/- 0.04 (MEC*); 0.67 +/- 0.06 (S100); and 0.67 +/- 0.08 (S200), and ventilatory pressure (cm H2O) was 9.0 +/- 0.9 (Control); 16.5 +/- 1.7 (MEC*); 12.4 +/- 1.1 (S100); and 12.1 +/- 1.5 (S200). Both treated groups had lower Lm values and more homogeneity in the lung parenchyma compared to the MEC group: SDI = 7.5 +/- 1.9 (Control); 11.3 +/- 2.5 (MEC*), 5.8 +/- 1.9 (S100); and 6.7 +/- 1.7 (S200) (*P < 0.05 versus all the other groups). CONCLUSIONS: Animals treated with surfactant showed significant improvement in pulmonary mechanics and more regularity of the lung parenchyma in comparison to untreated animals. There was no difference in results after treatment with either of the doses used.


Subject(s)
Lung Compliance/drug effects , Meconium Aspiration Syndrome/drug therapy , Pulmonary Gas Exchange/drug effects , Pulmonary Surfactants/administration & dosage , Respiratory Mechanics/drug effects , Animals , Animals, Newborn , Disease Models, Animal , Female , Humans , Infant, Newborn , Male , Rabbits , Respiration, Artificial , Time Factors
5.
Rev. Hosp. Clin. Fac. Med. Univ. Säo Paulo ; 59(3): 104-112, June 2004. tab, graf
Article in English | LILACS | ID: lil-363368

ABSTRACT

OBJETIVO: Avaliar os efeitos de duas diferentes doses de surfactante exógeno sobre a mecânica pulmonar e sobre a regularidade da expansão do parênquima pulmonar em coelhos recém-nascidos. MÉTODO: Coelhos recém-nascidos foram traqueostomizados e randomizados em quatro grupos de estudo: grupo-Controle, sem aspiração de mecônio; grupo MEC, com aspiração de mecônio e sem tratamento com surfactante exógeno; grupos S100 e S200, ambos com aspiração de mecônio e tratados respectivamente com 100 e 200 mg/kg de surfactante exógeno (produzido e fornecido pelo Instituto Butantan). Os animais dos 4 grupos foram ventilados por 25 minutos. A mecânica pulmonar foi avaliada a partir dos valores de complacência dinâmica, pressão ventilatória, volume-corrente e volume pulmonar máximo (curva P-V). A análise histológica foi feita calculando-se o diâmetro alveolar médio (Lm) e o índice de distorção através do desvio padrão do Lm. Utilizou-se ANOVA One Way com a = 0,05. RESULTADOS: Após 25 minutos de ventilação, os valores de complacência dinâmica (ml/cm H2O.kg) foram: 0,87± 0,07 (Controle); 0,49±0,04 (MEC*); 0,67±0,06 (S100) e 0,67±0,08 (S200) e de pressão ventilatória (cm H2O): 9,0± 0,9 (Controle); 16,5±1,7 (MEC*); 12,4±1,1 (S100) e 12,1±1,5 (S200). Ambos os grupos tratados tiveram padrão de expansão do parênquima mais homogêneo em relação aos animais não tratados: índice de distorção de 7,5± 1,9 (Controle); 11,3±2,5 (MEC*); 5,8±1,9 (S100) e 6,7±1,7 (S200) (*p < 0,05 vs outros grupos). CONCLUSÕES: Animais tratados com surfactante mostraram melhora significativa da mecânica pulmonar e maior homogeneidade do padrão de expansão pulmonar comparados ao grupo não tratado. Não houve influência das doses de surfactante utilizadas.


Subject(s)
Animals , Female , Humans , Infant, Newborn , Male , Rabbits , Lung Compliance/drug effects , Meconium Aspiration Syndrome/drug therapy , Pulmonary Gas Exchange/drug effects , Pulmonary Surfactants/administration & dosage , Respiratory Mechanics/drug effects , Animals, Newborn , Disease Models, Animal , Respiration, Artificial , Time Factors
6.
Pediatria (Säo Paulo) ; 17(4): 174-90, 1995. tab
Article in Portuguese | LILACS | ID: lil-186903

ABSTRACT

A anemia da prematuridade é uma entidade clínica frequentemente encontrada em berçários de alto risco. O aumento da sua incidência é decorrente da melhoria nos cuidados neonatais com consequente aumento da sobrevida dos recém-nascidos pré-termo (RN-PT) e de muito baixo peso. A sua apresentaçäo e/ou manifestaçöes clínicas, muitas vezes, levam a internaçöes prolongadas com tratamentos onerosos, cuja eficácia ainda é discutida. Com o enfoque na fisiopatologia da anemia da prematuridade, é apresentada uma revisäo da literatura recente sobre este assunto, as propostas de tratamento e, particularmente, a respeito do novo tratamento utilizando-se a eritropoetina recombinante humana (rhEPO). Discute-se, com detalhes, a sua indicaçäo, baseada em todos os estudos clínicos realizados com o uso da rhEPO na anemia da prematuridade até o momento


Subject(s)
Humans , Anemia/physiopathology , Erythropoiesis , Infant, Premature , Anemia/therapy , Erythropoietin/administration & dosage , Gestational Age , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL