Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters











Database
Language
Publication year range
1.
Cureus ; 16(2): e54160, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38357406

ABSTRACT

Ventriculoperitoneal (VP) shunts are catheters inserted to drain excess cerebrospinal fluid (CSF) when there is an obstruction in the normal outflow or a decreased absorption of the fluid leading to hydrocephalus. Recognised complications of placement of the distal catheter are malposition, obstruction, pseudocysts and infection. Here, we present a case of a 23-year-old female with acute pancreatitis following the placement of a VP shunt in the lesser sac. The patient originally had a VP shunt placed in infancy for congenital hydrocephalus with one revision at four years old. She presented with a three-day history of worsening epigastric pain with an associated lipase of 3030 (10-60IU), CRP 157 (<5mg/L) and normal liver function tests. A CT scan showed acute pancreatitis with an associated collection within the lesser sac extending to the greater omentum. This was due to the malposition of the VP shunt after a recent revision surgery. It was managed with a diagnostic laparoscopy, washout and shunt externalisation. This is an atypical presentation of acute pancreatitis secondary to a VP shunt. A high index of suspicion is needed for diagnosis. Management of both pancreatitis and VP shunt complications need to be considered.

2.
J Endourol ; 35(6): 903-907, 2021 06.
Article in English | MEDLINE | ID: mdl-27981862

ABSTRACT

Introduction: A novel single-use flexible ureteroscope promises the optical characteristics and maneuverability of a reusable fourth-generation flexible ureteroscope. In this study, the LithoVue Single-Use Digital flexible ureteroscope was directly compared with contemporary reusable flexible ureteroscopes, with regard to optics, deflection, and irrigation flow. Methods: Three flexible ureteroscopes such as the LithoVue (Single Use; Boston Scientific), Flex-Xc (Karl Storz, Germany), and Cobra (Richard Wolf, Germany) were assessed in vitro for image resolution, distortion, color representation, grayscale imaging, field of view, and depth of field. Ureteroscope deflection was tested with an empty channel followed by placement of a 200 µm laser fiber and a 1.9F wire basket, a 2.0F nanoelectric pulse lithotripsy (NPL) probe, and a 2.4F NPL probe. Ureteroscope irrigation flow was measured using normal saline at 100 cm, with an empty channel followed by a 200 µm laser fiber, a 1.9F wire basket and a 2.0F NPL probe. Results: The LithoVue showed the largest field of view, with excellent resolution, image distortion, and depth of field. No substantial difference was demonstrated in color reproducibility or in the discernment of grayscales between ureteroscopes. The LithoVue maintained full deflection ability with all instruments in the working channel, although the Flex-Xc and Cobra ureteroscopes showed loss of deflection ranging from 2° to 27°, depending on the instrument placed. With an empty channel, the LithoVue showed an absolute flow rate similar to the Flex-Xc ureteroscope (p = 0.003). It maintained better flow with instruments in the channel than the Flex-Xc ureteroscope. The Cobra ureteroscope has a separate 3.3F instrument channel, keeping flow rates the same with instrument insertion. Conclusion: The LithoVue Single-Use Digital ureteroscope has comparable optical capabilities, deflection, and flow, making it a viable alternative to standard reusable fourth-generation flexible digital and fiberoptic ureteroscopes.


Subject(s)
Ureteroscopes , Ureteroscopy , Equipment Design , Germany , Reproducibility of Results
4.
J Infect Chemother ; 23(12): 830-832, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28803865

ABSTRACT

Ureaplasma urealyticum is a urogenital commensal and often associated with localised infection. With the advent of monoclonal immunosuppressive therapy and improved diagnostic methods, reports of non-urogenital infections are accumulating. We report a rare case of U. urealyticum necrotizing soft tissue infection and left hip septic arthritis in a hypogammaglobulinaemic patient. Consideration of this organism as an etiological agent, and potential early use of nucleic-acid diagnostic investigation with empiric therapy including activity against Ureaplasma in this patient population may be warranted.


Subject(s)
Arthritis, Infectious/diagnosis , Arthritis, Infectious/microbiology , Soft Tissue Infections/diagnosis , Soft Tissue Infections/microbiology , Ureaplasma Infections/diagnosis , Ureaplasma Infections/microbiology , Ureaplasma urealyticum/isolation & purification , Agammaglobulinemia , Antineoplastic Agents/adverse effects , Antineoplastic Agents/therapeutic use , Female , Hip , Humans , Lymphoma, Mantle-Cell/complications , Lymphoma, Mantle-Cell/drug therapy , Middle Aged , Necrosis , Pelvis , Polymerase Chain Reaction , Ureaplasma urealyticum/genetics
5.
J Endourol ; 31(7): 623-629, 2017 07.
Article in English | MEDLINE | ID: mdl-28401803

ABSTRACT

The prevalence of urinary stones in the United States has been described as 1 in 11 persons reporting a history of stones. Imaging plays a crucial role in diagnosis, management, and follow-up for these patients and imaging technology over the last 100 years has advanced as the disease prevalence has increased. CT remains the gold standard for imaging urolithiasis and changes in this technology, with the addition of multidetector CT and dual-energy CT, as well as the changes in utilization of CT, have decreased the radiation dose encountered by patients and allowed for improved stone detection. The use of digital tomography has been introduced for follow-up of recurrent stone formers offering the potential to lower radiation exposure over the course of a patient's lifelong treatment. However, there is still a demand for improved imaging techniques to detect smaller stones and stones in larger patients at lower radiation doses as well as the continued need for the judicious use of all imaging modalities for healthcare cost containment and patient safety.


Subject(s)
Tomography, X-Ray Computed/methods , Urolithiasis/diagnostic imaging , Fluoroscopy/methods , Fluoroscopy/trends , Humans , Radiation Exposure/prevention & control , Radiography, Abdominal/methods , Radiography, Abdominal/trends , Tomography, X-Ray Computed/trends
7.
J Endourol ; 30(11): 1150-1154, 2016 11.
Article in English | MEDLINE | ID: mdl-27736195

ABSTRACT

INTRODUCTION: The Nanopulse Lithotripter (NPL; Lithotech Medical, Israel) is a novel intracorporeal device that uses a nanosecond duration electrical discharge through a reusable flexible coaxial probe to endoscopically fragment urinary stones. This device was compared with a holmium laser lithotripsy (HoL) with regard to stone fragmentation efficiency (SFE) and its impact on flexible ureteroscope (URS) deflection and flow of irrigation. METHODS: Using a custom bench model, a 6 mm BegoStone cylindrical phantom (mixture 5:2) was confined under 0.9% saline atop sequential mesh sieves. The SFE of two NPL probe sizes (2.0F, 3.6F) and two HoL fibers (200, 365 µm) was evaluated using concordant settings of 1 J and 5 Hz. URS deflection and irrigation flow with NPL probes in the working channel were tested in five new fourth generation flexible URS and compared with other adjunct endourologic instruments. RESULTS: The 2.0F NPL showed improved SFE compared with the 200 µm laser (86 mg/min vs 52 mg/min, p = 0.014) as did the 3.6F NPL vs the 365 µm laser (173 mg/min vs 80 mg/min, p = 0.05). The NPL created more 1 to 2 mm fragments; the laser created more dust. URS deflection reduced by 3.75° with the 2.0 NPL probe. URS irrigation flow reduced from 36.5 to 6.3 mL/min with the 2.0F NPL probe. CONCLUSION: NPL shows improved SFE compared with HoL. Flow with the 2.0F probe is akin to a stone basket. NPL offers an effective alternative to HoL.


Subject(s)
Lasers, Solid-State/therapeutic use , Lithotripsy, Laser/instrumentation , Urinary Calculi/therapy , Endoscopy/methods , Equipment Design , Holmium , Humans , Lithotripsy, Laser/methods , Phantoms, Imaging , Ureteroscopes , Ureteroscopy/methods , Urolithiasis/therapy
8.
J Clin Microbiol ; 48(11): 3852-8, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20739493

ABSTRACT

Rapid and effective methods for the isolation of Clostridium difficile from stool samples are desirable to obtain isolates for typing or to facilitate accurate diagnosis of C. difficile-associated diarrhea. We report on the evaluation of a prototype chromogenic medium (ID C. difficile prototype [IDCd]) for isolation of C. difficile. The chromogenic medium was compared using (i) 368 untreated stool samples that were also inoculated onto CLO medium, (ii) 339 stool samples that were subjected to alcohol shock and also inoculated onto five distinct selective agars, and (iii) standardized suspensions of 10 C. difficile ribotypes (untreated and alcohol treated) that were also inoculated onto five distinct selective agars. Two hundred thirty-six isolates of C. difficile were recovered from 368 untreated stool samples, and all but 1 of these strains (99.6%) were recovered on IDCd within 24 h, whereas 74.6% of isolates were recovered on CLO medium after 48 h. Of 339 alcohol-treated stool samples cultured onto IDCd and five other selective agars, C. difficile was recovered from 218 samples using a combination of all media. The use of IDCd allowed recovery of 96.3% of isolates within 24 h, whereas 51 to 83% of isolates were recovered within 24 h using the five other media. Finally, when they were challenged with pure cultures, all 10 ribotypes of C. difficile generated higher colony counts on IDCd irrespective of alcohol pretreatment or duration of incubation. We conclude that IDCd is an effective medium for isolation of C. difficile from stool samples within 24 h.


Subject(s)
Bacteriological Techniques/methods , Clostridioides difficile/isolation & purification , Culture Media/chemistry , Enterocolitis, Pseudomembranous/diagnosis , Chromogenic Compounds/metabolism , Enterocolitis, Pseudomembranous/microbiology , Humans , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL