Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
Ecotoxicol Environ Saf ; 197: 110570, 2020 Jul 01.
Article in English | MEDLINE | ID: mdl-32311611

ABSTRACT

In recent times, however, due to the emergence of bacterial strains with resistance to conventional antibiotics, silver has again gained attention as an alternative for developing new efficient bactericides, including the use of silver nanoparticles (AgNPs). However, the improper disposal of these items after use may cause toxicological effects on organisms in the environment. To evaluate the potential environmental hazard of nanosilver-coated dressings, the nematode Caenorhabditis elegans was chosen as a test organism. The assays were conducted in 24-well plates that contain four different sizes of coated dressing to obtain different concentrations. L1 and L4 C. elegans larval stages were exposed to these nanosilver concentrations. Dressing cutouts were arranged between two layers of agar for 3 days and Escherichia coli (OP 50 strain) was added as food source for the worms. After the exposure period, growth, reproduction, fertility, silver concentration in the medium and the concentration of reactive oxygen species (ROS) in the worms were evaluated. Scanning and transmission electron microscopy analyses were performed on the coated dressings, as well as analyses of zeta potential, ionic release and antibacterial power in two bacterial strains (Pseudomonas aeruginosa and Staphylococcus aureus). It was verified the antibacterial power of the coated dressing, in both bacteria strains tested. Characterization of the coated dressing indicated heterogeneous nanoparticles, as well as distinct zeta potentials for the medium in water and saline medium (0.9% NaCl). L1 larval worms exposed to nanosilver-coated dressing showed a high ROS concentration and reductions in growth, fertility and reproduction. Worms exposed to the coated dressing during the L4 stage showed almost no response. Overall, the obtained results indicate the potential environmental hazard of nanosilver-coated dressings.


Subject(s)
Bandages , Caenorhabditis elegans/drug effects , Environmental Pollutants/toxicity , Metal Nanoparticles/toxicity , Silver/toxicity , Animals , Anti-Bacterial Agents/chemistry , Anti-Bacterial Agents/toxicity , Bacteria/drug effects , Caenorhabditis elegans/physiology , Environmental Pollutants/chemistry , Larva/drug effects , Larva/physiology , Metal Nanoparticles/chemistry , Reactive Oxygen Species/metabolism , Silver/chemistry
2.
J Ind Microbiol Biotechnol ; 35(9): 1041-6, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18536948

ABSTRACT

An antimicrobial coating was evaluated in this work for its antimicrobial efficacy against common food-borne pathogens. Dodecyl-di(aminoethyl)-glycine, an organic disinfectant, was immobilized in a silicon oxide matrix to generate thin films over surfaces by means of the sol-gel process. Tetraethoxysilane was used as the polymeric precursor. No alteration of optical transparency on the covered surfaces was observed. Topographic images obtained with atomic force microscopy showed a homogeneous film with no additional roughness added by the polymer to the surface. The attenuated total reflectance-Fourier transform infrared spectral data showed the presence of dodecyl-di(aminoethyl)-glycine in the silicon oxide network after a normal cleaning procedure. The antimicrobial efficacy test was performed by exposing coated slides to suspensions of common food-borne pathogens: Escherichia coli, Staphyloccocus aureus, E. coli O157:H7, Salmonella typhi, S. cholerasuiss, Listeria innocua and L. monocytogenes. The coating activity was not only bacteriostatic but also bactericidal. The percent reduction of viable microorganism exposure over 24 h to the coated surface ranged between 99.5%, for the more resistant gram-positive bacteria, and over 99.999%, for most gram-negative bacteria. The silicon matrix itself did not account for any reduction of viable microbial, even more an increase was observed.


Subject(s)
Anti-Infective Agents/pharmacology , Bacteria/drug effects , Disinfectants/pharmacology , Food Microbiology , Gels/pharmacology , Glycine/analogs & derivatives , Surface-Active Agents/pharmacology , Anti-Infective Agents/chemistry , Colony Count, Microbial , Disinfectants/chemistry , Food Industry/methods , Gels/chemistry , Glycine/chemistry , Glycine/pharmacology , Microscopy, Atomic Force , Spectrophotometry, Infrared , Spectrophotometry, Ultraviolet , Surface-Active Agents/chemistry
3.
J Pharm Biomed Anal ; 44(1): 305-8, 2007 May 09.
Article in English | MEDLINE | ID: mdl-17382505

ABSTRACT

A capillary zone electrophoretic (CZE) method has been developed for the determination of impurities (phosphyte and phosphate) in technical-grade ibandronate, which is a potent nitrogen-containing bisphosphonate. Successful separation of the drug from the impurities was achieved using 1mM tetradecyl-trimethyl-ammonium bromide (TTAB) and 5mM potassium chromate (pH 10.0) as background electrolyte with an indirect detection at 254 nm. The optimised method was validated for specificity, precision, linearity and accuracy. The limit of detection (LOD) was 2 microg/mL and the limit of quantification (LOQ) was 7 microg/mL for both phosphyte and phosphate. The developed CZE method used to determine phosphyte and phosphate as bisphosphonates impurities can be used to evaluate the quality of regular production samples of ibandronate.


Subject(s)
Bone Density Conservation Agents/analysis , Diphosphonates/analysis , Drug Contamination , Electrophoresis, Capillary/methods , Chromates/chemistry , Electrophoresis, Capillary/instrumentation , Hydrogen-Ion Concentration , Ibandronic Acid , Phosphates/analysis , Phosphites/analysis , Potassium Compounds/chemistry , Reproducibility of Results , Sensitivity and Specificity , Spectrophotometry, Ultraviolet , Trimethyl Ammonium Compounds/chemistry
4.
J Ind Microbiol Biotechnol ; 33(5): 343-8, 2006 May.
Article in English | MEDLINE | ID: mdl-16341729

ABSTRACT

The antimicrobial compound dodecyl-di(aminoethyl)-glycine was immobilized in a silicon oxide xerogel matrix and used for glass surface coating. Coated glasses were tested for surface antimicrobial activity. The utilization of tetraethoxysilane (TEOS) as a silicon oxide polymer precursor, using the dip-coating process, allowed for the generation of transparent thin films over glass surfaces. Different concentrations of the antimicrobial compound were used to generate the coatings. The presence of dodecyl-di(aminoethyl)-glycine on coated and uncoated slides was analyzed by FT-IR spectra. Coated glass slides were exposed to suspensions of Escherichia coli, Pseudomonas aeruginosa and Staphylococcus aureus for 24 h. Surface contamination was evaluated by the microbial plate count technique. When antimicrobial-coated glasses were compared with antimicrobial-free coated glasses, the former showed greater than 99% reduction of colony-forming units (cfu) for E. coli and P. aeruginosa, when 1% of antimicrobial was present in the coating solution. The same percentage of reduction for S. aureus was achieved when 1.5% of the antimicrobial was present in the coating solution. In a direct inhibition test on agar plates, no inhibitory zone was observed, indicating that the antimicrobial did not diffuse into the media.


Subject(s)
Anti-Infective Agents/pharmacology , Disinfectants/pharmacology , Glass/chemistry , Anti-Infective Agents/chemistry , Disinfectants/chemistry , Dose-Response Relationship, Drug , Escherichia coli/drug effects , Glycine/analogs & derivatives , Glycine/chemistry , Glycine/pharmacology , Pseudomonas aeruginosa/drug effects , Silanes/chemistry , Staphylococcus aureus/drug effects
SELECTION OF CITATIONS
SEARCH DETAIL