Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Bone Joint J ; 101-B(5): 540-546, 2019 05.
Article in English | MEDLINE | ID: mdl-31039002

ABSTRACT

AIMS: Cardiac magnetic resonance (CMR) was used to assess whether cardiac function or tissue composition was affected in patients with well-functioning metal-on-metal hip resurfacing arthroplasties (MoMHRA) when compared with a group of controls, and to assess if metal ion levels correlated with any of the functional or structural parameters studied. PATIENTS AND METHODS: In all, 30 participants with no significant cardiac history were enrolled: 20 patients with well-functioning MoMHRA at mean follow-up of 8.3 years post-procedure (ten unilateral, ten bilateral; 17 men, three women) and a case-matched control group of ten non-MoM total hip arthroplasty patients (six men, four women). The mean age of the whole cohort (study group and controls) at the time of surgery was 50.6 years (41.0 to 64.0). Serum levels of cobalt and chromium were measured, and all patients underwent CMR imaging, including cine, T2* measurements, T1 and T2 mapping, late gadolinium enhancement, and strain measurements. RESULTS: None of the MoMHRA patients showed clinically significant cardiac functional abnormality. The MoMHRA patients had larger indexed right and left end diastolic volumes (left ventricular (LV): 74 ml/m2vs 67 ml/m2, p = 0.045; right ventricular: 80 ml/m2vs 71 ml/m2, p = 0.02). There was a small decrease in T2 time in the MoMHRA patients (median 49 ms vs 54 ms; p = 0.0003). Higher metal ion levels were associated with larger LV volumes and with shorter T2 time. CONCLUSION: Although cardiac function is not clinically adversely affected in patients with well-functioning MoMHRA, modern imaging is able to demonstrate subtle changes in structure and function of the heart. As these changes correlate with systemic ion measurements, they may be consequences of wear debris deposition. Longer, longitudinal studies are necessary to determine whether cardiac function will become affected. Cite this article: Bone Joint J 2019;101-B:540-546.


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Heart/diagnostic imaging , Hip Joint/surgery , Hip Prosthesis/adverse effects , Magnetic Resonance Imaging, Cine/methods , Metal-on-Metal Joint Prostheses/adverse effects , Adult , Aged , Case-Control Studies , Chromium/blood , Cobalt/blood , Female , Heart/physiopathology , Hip Joint/diagnostic imaging , Humans , Male , Middle Aged , Postoperative Complications/diagnostic imaging , Postoperative Complications/etiology
2.
Bone Joint J ; 100-B(10): 1280-1288, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30295537

ABSTRACT

AIMS: This study aims to: determine the difference in pelvic position that occurs between surgery and radiographic, supine, postoperative assessment; examine how the difference in pelvic position influences subsequent component orientation; and establish whether differences in pelvic position, and thereafter component orientation, exist between total hip arthroplasties (THAs) performed in the supine versus the lateral decubitus positions. PATIENTS AND METHODS: The intra- and postoperative anteroposterior pelvic radiographs of 321 THAs were included; 167 were performed with the patient supine using the anterior approach and 154 were performed with the patient in the lateral decubitus using the posterior approach. The inclination and anteversion of the acetabular component was measured and the difference (Δ) between the intra- and postoperative radiographs was determined. The target zone was inclination/anteversion of 40°/20° (± 10°). Changes in the tilt, rotation, and obliquity of the pelvis on the intra- and postoperative radiographs were calculated from Δinclination/anteversion using the Levenberg-Marquardt algorithm. RESULTS: The mean postoperative inclination/anteversion was 40° (± 8°)/23° (± 9°) with Δinclination and/or Δanteversion > ± 10° in 74 (21%). Intraoperatively, the pelvis was anteriorly tilted by a mean of 4° (± 10°), internally rotated by a mean of 1° (± 10°) and adducted by a mean of 1° (± 5°). Having Δinclination and/or Δanteversion > ± 10° was associated with a 3.5 odds ratio of having the acetabular component outside the target zone. A greater proportion of THAs that were undertaken with the patient in the lateral decubitus position had Δinclination and/or Δanteversion > ± 10° (35.3%, 54/153) compared with those in the supine position (4.8%, 8/167; p < 0.001). A greater number of acetabular components were within the target zone in THAs undertaken with the patient in the supine position (72%, 120/167), compared with those in the lateral decubitus position (44%, 67/153; p < 0.001). Intraoperatively, the pelvis was more anteriorly tilted (p < 0.001) and more internally rotated (p = 0.04) when the patient was in the lateral decubitus position. CONCLUSION: The pelvic position is more reliable when the patient is in the supine position, leading to more consistent orientation of the acetabular component. Significant differences in pelvic tilt and rotation are seen with the patient in the lateral decubitus position. Cite this article: Bone Joint J 2018;100-B:1280-8.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Bone Anteversion/prevention & control , Patient Positioning/methods , Pelvic Bones/physiopathology , Postoperative Complications/prevention & control , Supine Position , Acetabulum , Aged , Arthroplasty, Replacement, Hip/instrumentation , Bone Anteversion/diagnostic imaging , Bone Anteversion/etiology , Female , Hip Prosthesis , Humans , Male , Middle Aged , Outcome Assessment, Health Care , Pelvic Bones/diagnostic imaging , Postoperative Complications/diagnostic imaging , Radiography , Retrospective Studies
3.
Bone Joint J ; 99-B(3): 303-309, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28249968

ABSTRACT

AIMS: Joint-preserving surgery of the hip (JPSH) has evolved considerably and now includes a number of procedures, including arthroscopy, surgical dislocation, and redirectional osteotomies of the femur and acetabulum. There are a number of different factors which lead to failure of JPSH. Consequently, it is of interest to assess the various modes of failure in order to continue to identify best practice and the indications for these procedures. PATIENTS AND METHODS: Using a retrospective observational study design, we reviewed 1013 patients who had undergone JPSH by a single surgeon between 2005 and 2015. There were 509 men and 504 women with a mean age of 39 years (16 to 78). Of the 1013 operations, 783 were arthroscopies, 122 surgical dislocations, and 108 peri-acetabular osteotomies (PAO). We analysed the overall failure rates and modes of failure. Re-operations were categorised into four groups: Mode 1 was arthritis progression or organ failure leading to total hip arthroplasty (THA); Mode 2 was an Incorrect diagnosis/procedure; Mode 3 resulted from malcorrection of femur (type A), acetabulum (type B), or labrum (type C) and Mode 4 resulted from an unintended consequence of the initial surgical intervention. RESULTS: At a mean follow-up of 2.5 years, there had been 104 re-operations (10.2%) with a mean patient age of 35.5 years (17 to 64). There were 64 Mode 1 failures (6.3%) at a mean of 3.2 years following JPSH with a mean patient age of 46.8 years (18 to 64). There were 17 Mode 2 failures (1.7%) at a mean of 2.2 years post-JPSH with a mean patient age of 28.9 years (17 to 42) (2% scopes; 1% surgical dislocations). There were 19 Mode 3 failures (1.9%) at a mean of 2.0 years post-JPSH, with a mean patient age of 29.9 years (18 to 51) (2% scopes; 2% surgical dislocations; 5% PAO). There were 4 Mode 4 failures (0.4%) at a mean of 1.8 years post-JPSH with a mean patient age of 31.5 years (15 to 43). Using the modified Dindo-Clavien classification system, the overall complication rate among JPSHs was 4.2%. CONCLUSION: While defining the overall re-operation and complication rates, it is important to define the safety and effectiveness of JPSH. Standardisation of the modes of failure may help identify the best practice. Application of these modes to large clinical series, such as registries, will assist in further establishing how to improve the efficacy of JPSH. Cite this article: Bone Joint J 2017;99-B:303-9.


Subject(s)
Acetabulum/surgery , Osteoarthritis, Hip/surgery , Adolescent , Adult , Aged , Arthroplasty, Replacement, Hip , Arthroscopy/adverse effects , Arthroscopy/methods , Disease Progression , Female , Femur/surgery , Humans , Male , Middle Aged , Osteotomy/adverse effects , Osteotomy/methods , Reoperation/adverse effects , Reoperation/methods , Reoperation/statistics & numerical data , Retrospective Studies , Risk Factors , Treatment Failure , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL