ABSTRACT
Stereotactic body radiation therapy is a novel treatment option for refractory ventricular tachycardia. We present a case of ventricular tachycardia, with epicardial origin located in large inferior infarct scar, that recurred despite treatment with multiple antiarrhythmic drugs, catheter ablation, and cardiac sympathetic denervation. Stereotactic body radiation therapy safely and effectively terminated the arrhythmia. (Level of Difficulty: Advanced.).
ABSTRACT
OBJECTIVES: This study investigates the correlation of occlusive wedge pressure (WP) with direct left atrial (LA) pressure in patients with severe mitral regurgitation (MR) undergoing transcatheter mitral valve repair (TMVr) with MitraClip. BACKGROUND: There is interest in acquiring objective hemodynamic parameters for intraprocedural guidance in patients undergoing MitraClip. METHODS: The study included 94 patients with severe MR at prohibitive surgical risk who underwent MitraClip at the University of California Davis Medical Center between 2014 and 2016. RESULTS: An average of 1.8 ± 0.7 clips were used to achieve MR grade of 2+ or less in 99% of patients. Correlation analysis of all (n = 236) pre-clip, inter-clip, and final-clip WP and LA pressures yielded a Pearson's R (r) of 0.85 and 0.79 for mean WP vs mean LA and WP V vs LA V, respectively. Median LA V to mean LA ratio (LAV:mLA) was 1.75 (IQR 1.5-1.9). 79% (n = 74) of patients had LAV:mLA ratio ≥ 1.5 with associated WP V vs LA V correlation (r) of 0.83. In patients with LAV:mLA ratio < 1.5, the correlation (r) was 0.69. Baseline characteristics were not significantly different between patients with LAV:mLA ratio ≥ 1.5 and patients with LAV:mLA ratio < 1.5. Post-procedure, median LA V: mean LA ratio decreased from 1.75 to 1.4, P = 0.0001. CONCLUSIONS: Correlation between WP and direct LA pressure in patients with severe MR undergoing Mitraclip is modest. Caution is advised when using WP to approximate LA pressure intraprocedurally, especially in patients with baseline low LAV:mLA ratios.
Subject(s)
Atrial Function, Left , Atrial Pressure , Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Monitoring, Intraoperative , Pulmonary Wedge Pressure , Aged , Aged, 80 and over , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Female , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Humans , Male , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Prosthesis Design , Registries , Retrospective Studies , Severity of Illness Index , Time Factors , Treatment OutcomeABSTRACT
Late type III endoleaks result from complete or partial separation of endograft device components. Component separation repressurizes the aortic sac and may result in aortic rupture. We report 4 cases of late type III endoleaks after initial successful endovascular aneurysm repair for abdominal aortic aneurysm. Our cases include 3 aortic cuff separations and 1 iliac limb separation. The average time before graft separation was 3.25 years with an average aneurysm size at re-presentation of 8.2 cm. Management of these complex cases will be discussed, the literature reviewed, and recommendations for treatment offered.