Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 16(11): e0260066, 2021.
Article in English | MEDLINE | ID: mdl-34793550

ABSTRACT

We compared lesion-based sensitivity of dual-time-point FDG-PET/CT, bone scintigraphy (BS), and low-dose CT (LDCT) for detection of various types of bone metastases in patients with metastatic breast cancer. Prospectively, we included 18 patients with recurrent breast cancer who underwent dual-time-point FDG-PET/CT with LDCT and BS within a median time interval of three days. A total of 488 bone lesions were detected on any of the modalities and were categorized by the LDCT into osteolytic, osteosclerotic, mixed morphologic, and CT-negative lesions. Lesion-based sensitivity was 98.2% (95.4-99.3) and 98.8% (96.8-99.5) for early and delayed FDG-PET/CT, respectively, compared with 79.9% (51.1-93.8) for LDCT, 76.0% (36.3-94.6) for BS, and 98.6% (95.4-99.6) for the combined BS+LDCT. BS detected only 51.2% of osteolytic lesions which was significantly lower than other metastatic types. SUVs were significantly higher for all lesion types on delayed scans than on early scans (P<0.0001). Osteolytic and mixed-type lesions had higher SUVs than osteosclerotic and CT-negative metastases at both time-points. FDG-PET/CT had significantly higher lesion-based sensitivity than LDCT and BS, while a combination of the two yielded sensitivity comparable to that of FDG-PET/CT. Therefore, FDG-PET/CT could be considered as a sensitive one-stop-shop in case of clinical suspicion of bone metastases in breast cancer patients.


Subject(s)
Neoplasm Metastasis/diagnostic imaging , Neoplasm Recurrence, Local/diagnostic imaging , Bone Neoplasms/diagnostic imaging , Bone and Bones/cytology , Bone and Bones/diagnostic imaging , Breast/cytology , Breast Neoplasms/complications , Breast Neoplasms/diagnostic imaging , Diagnostic Tests, Routine/methods , Female , Fluorodeoxyglucose F18 , Humans , Positron Emission Tomography Computed Tomography/methods , Positron-Emission Tomography/methods , Radionuclide Imaging/methods , Sensitivity and Specificity , Tomography, X-Ray Computed/methods
2.
Diagnostics (Basel) ; 10(12)2020 Nov 28.
Article in English | MEDLINE | ID: mdl-33260766

ABSTRACT

The purpose was to investigate the interrater agreement of FDG-PET/CT and bone scintigraphy for diagnosing bone recurrence in breast cancer patients. A total of 100 women with suspected recurrence of breast cancer underwent planar whole-body bone scintigraphy with [99mTc]DPD and FDG-PET/CT. Scans were evaluated independently by experienced nuclear medicine physicians and the results for one modality were blinded to the other. Images were visually interpreted using a 4-point assessment scale (0 = no metastases, 1 = probably no metastases, 2 = probably metastases, 3 = definite metastases). Out of 100 women, 22 (22%) were verified with distant recurrence, 18 of these had bone involvement. The proportions of agreement between readers were 93% (86.3-96.6) for bone recurrence with FDG-PET/CT and 47% (37.5-56.7) for bone recurrence with planar bone scintigraphy. The strengths of agreement between readers for diagnosing bone recurrence was 'almost perfect' with FDG-PET/CT and was 'fair' with planar bone scintigraphy according to Cohen's kappa value of 0.82 (0.70-0.95) and 0.28 (0.18-0.39), respectively. Interrater agreement yielded improved reproducibility with FDG-PET/CT versus with bone scintigraphy when diagnosing recurrence with bone metastasis in this patient cohort.

3.
BMC Med Imaging ; 18(1): 11, 2018 05 09.
Article in English | MEDLINE | ID: mdl-29743027

ABSTRACT

BACKGROUND: Several studies have shown the advantage of delayed-time-point imaging with 18F-FDG-PET/CT to distinguish malignant from benign uptake. This may be relevant in cancer diseases with low metabolism, such as breast cancer. We aimed at examining the change in SUV from 1 h (1h) to 3 h (3h) time-point imaging in local and distant lesions in patients with recurrent breast cancer. Furthermore, we investigated the effect of partial volume correction in the different types of metastases, using semi-automatic quantitative software (ROVER™). METHODS: One-hundred and two patients with suspected breast cancer recurrence underwent whole-body PET/CT scans 1h and 3h after FDG injection. Semi-quantitative standardised uptake values (SUVmax, SUVmean) and partial volume corrected SUVmean (cSUVmean), were estimated in malignant lesions, and as reference in healthy liver tissue. The change in quantitative measures from 1h to 3h was calculated, and SUVmean was compared to cSUVmean. Metastases were verified by biopsy. RESULTS: Of the 102 included patients, 41 had verified recurrent disease with in median 15 lesions (range 1-70) amounting to a total of 337 malignant lesions included in the analysis. SUVmax of malignant lesions increased from 6.4 ± 3.4 [0.9-19.7] (mean ± SD, min and max) at 1h to 8.1 ± 4.4 [0.7-29.7] at 3h. SUVmax in breast, lung, lymph node and bone lesions increased significantly (p < 0.0001) between 1h and 3h by on average 25, 40, 33, and 27%, respectively. A similar pattern was observed with (uncorrected) SUVmean. Partial volume correction increased SUVmean significantly, by 63 and 71% at 1h and 3h imaging, respectively. The highest impact was in breast lesions at 3h, where cSUVmean increased by 87% compared to SUVmean. CONCLUSION: SUVs increased from 1h to 3h in malignant lesions, SUVs of distant recurrence were in general about twice as high as those of local recurrence. Partial volume correction caused significant increases in these values. However, it is questionable, if these relatively modest quantitative advances of 3h imaging are sufficient to warrant delayed imaging in this patient group. TRIAL REGISTRATION: ClinicalTrails.gov NCT01552655 . Registered 28 February 2012, partly retrospectively registered.


Subject(s)
Breast Neoplasms/diagnostic imaging , Fluorodeoxyglucose F18/administration & dosage , Neoplasm Metastasis/diagnostic imaging , Neoplasm Recurrence, Local/diagnostic imaging , Aged , Breast Neoplasms/metabolism , Diagnosis, Differential , Female , Humans , Middle Aged , Neoplasm Recurrence, Local/metabolism , Positron Emission Tomography Computed Tomography/methods , Retrospective Studies , Time Factors , Whole Body Imaging/methods
4.
J Clin Oncol ; 34(16): 1889-97, 2016 06 01.
Article in English | MEDLINE | ID: mdl-27001573

ABSTRACT

PURPOSE: To prospectively investigate the diagnostic accuracy of [(18)F]fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) with dual-time-point imaging, contrast-enhanced CT (ceCT), and bone scintigraphy (BS) in patients with suspected breast cancer recurrence. PATIENTS AND METHODS: One hundred women with suspected recurrence of breast cancer underwent 1-hour and 3-hour FDG-PET/CT, ceCT, and BS within approximately 10 days. The study was powered to estimate the precision of the individual imaging tests. Images were visually interpreted using a four-point assessment scale, and readers were blinded to other test results. The reference standard was biopsy along with treatment decisions and clinical follow-up (median, 17 months). RESULTS: FDG-PET/CT resulted in no false negatives and fewer false positives than the other imaging techniques. Accuracy of results were similar for 1-hour and 3-hour FDG-PET/CT. For distant recurrence, the area under the receiver operating curve was 0.99 (95% CI, 0.97 to 1) for FDG-PET/CT, 0.84 (95% CI, 0.73 to 0.94) for ceCT, and 0.86 (95% CI, 0.77 to 0.94) for the combined ceCT+BS. Of 100 patients, 22 (22%) were verified with distant recurrence, and 18 of these had bone involvement. Nineteen patients (19%) had local recurrence only. In exploratory analyses, diagnostic accuracy of FDG-PET/CT was better than ceCT alone or ceCT combined with BS in diagnosing distant, bone, and local recurrence, shown by a greater area under the receiver operating curve and higher sensitivity, specificity, and superior likelihood ratios. CONCLUSION: FDG-PET/CT was accurate in diagnosing recurrence in breast cancer patients. It allowed for distant recurrence to be correctly ruled out and resulted in only a small number of false-positive cases. Exploratory findings suggest that FDG-PET/CT has greater accuracy than conventional imaging technologies in this patient group.


Subject(s)
Bone and Bones/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Fluorodeoxyglucose F18 , Neoplasm Recurrence, Local/diagnostic imaging , Positron Emission Tomography Computed Tomography/methods , Tomography, X-Ray Computed/methods , Contrast Media , Female , Humans , Prospective Studies , Radiographic Image Enhancement
SELECTION OF CITATIONS
SEARCH DETAIL
...