Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 173
Filter
1.
Nanoscale Adv ; 2024 Sep 16.
Article in English | MEDLINE | ID: mdl-39355839

ABSTRACT

Neuroprotection is an important approach for the treatment of spinal cord injury (SCI). Minocycline (MC), a known neuroprotective agent, has been utilized for SCI treatment, but its therapeutic effect is limited by instability and low bioavailability. Herein, we developed an innovative micellar thermosensitive hydrogel (MCPP-M-gel) that encapsulates MC in polyethylene glycol (PEG)-poly(lactide-co-glycolic acid) (PLGA) micelles to enhance its therapeutic efficacy in a rat model of SCI. The micelles were synthesized via the thin-film hydration method and characterized for encapsulation efficiency, particle size, zeta potential, and polydispersity index (PDI). MCPP-M-gel demonstrated favorable physico-mechanical properties and extended MC release over 72 hours in vitro without cytotoxic effects on neural crest-derived ectoderm mesenchymal stem cells (EMSCs). Thereafter, MC, MCPP-M, MCPP-M-gel and a blank micellar thermosensitive gel were injected into the injured site of SCI rats. Histopathological evaluation demonstrated that MCPP-M-gel could promote neuronal regeneration at the injured site of the SC after 28 days. Immunofluorescence techniques revealed that MCPP-M-gel increased the expression of neuronal class III ß-tubulin (Tuj1), myelin basic protein (MBP), growth-associated protein 43 (GAP43), neurofilament protein-200 (NF-200) and nestin as well as reduced glial-fibrillary acidic protein (GFAP) expression in damaged areas of the SC. In conclusion, this study innovatively developed MCPP-M-gel based on a PEG-PLGA copolymer as a biomaterial, laying a solid foundation for further research and application of MCPP-M-gel in SCI models or other neurodegenerative diseases.

2.
Talanta ; 282: 126959, 2024 Sep 25.
Article in English | MEDLINE | ID: mdl-39341062

ABSTRACT

Microcolumn gel immunoassay (MGIA) has the ability to meet the requirements of clinical diagnosis due to its reliable sensitivity and accuracy. However, traditional MGIA exhibits limitations including inadequate portability, low throughput, and extended analysis time. To address these challenges, we combined MGIA with microfluidic technology, demonstrating a centrifugal microfluidic-based microcolumn gel immunoassay (µMGIA) platform for blood typing of clinical samples. Experimental results indicate that the µMGIA platform can simultaneously detect six blood group antigens in five clinical blood samples within 2 min. Notably, it offers comprehensive detection of ABO blood group antigens and Rh blood group antigens with 100 % accuracy, outperforming the traditional slide method. The integration of microfluidic technology with MGIA circumvents the constraints of traditional methods, providing a new avenue for blood typing and immunoanalysis of clinical samples.

3.
Talanta ; 281: 126847, 2024 Sep 12.
Article in English | MEDLINE | ID: mdl-39276576

ABSTRACT

Heparin, a widely studied glycosaminoglycan, plays crucial roles in the regulation of various physiological and pathological processes. Therefore, it's important to develop highly selective and sensitive methods for convenient monitoring of heparin levels in biological systems. We report the design and synthesis of Fe3O4@PDA@MnO2 nanoparticles (FPM-NPs), which exhibit dual enzymatic activities, enabling quantitative detection of heparin. The FPM-NPs feature a unique tri-layer spherical shell structure, possessing both peroxidase-like and oxidase-like activities, and catalyze the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) in the presence or absence of H2O2. Remarkably, upon co-incubated with heparin, the oxidase activity of FPM-NPs decreases, while the peroxidase activity increases. By leveraging these dual enzymatic properties of FPM-NPs, a highly sensitive and specific colorimetric detection of heparin is achieved, with a detection limit reaching 6.51 nM and a good linear response to quantify heparin ranging 10-800 nM. Additionally, the developed FPM-NPs are successfully applied to measure heparin in fetal bovine serum samples. We also extend this detection method to a paper-based chip, enabling portable detection of heparin through grayscale analysis of mobile phone photographs. The multi-nanozyme-based heparin detection approach provides a new perspective for future research on expanding the application of nanocomposite materials in biomedical detection and analysis.

4.
ACS Biomater Sci Eng ; 2024 Sep 03.
Article in English | MEDLINE | ID: mdl-39227180

ABSTRACT

With the accelerating trend of global aging, bone damage caused by orthopedic diseases, such as osteoporosis and fractures, has become a shared international event. Traffic accidents, high-altitude falls, and other incidents are increasing daily, and the demand for bone implant treatment is also growing. Although extensive research has been conducted in the past decade to develop medical implants for bone regeneration and healing of body tissues, due to their low biocompatibility, weak bone integration ability, and high postoperative infection rates, pure titanium alloys, such as Ti-6A1-4V and Ti-6A1-7Nb, although widely used in clinical practice, have poor induction of phosphate deposition and wear resistance, and Ti-Zr alloy exhibits a lack of mechanical stability and processing complexity. In contrast, the Ti-Ni alloy exhibits toxicity and low thermal conductivity. Nonthermal plasma (NTP) has aroused widespread interest in synthesizing and modifying implanted materials. More and more researchers are using plasma to modify target catalysts such as changing the dispersion of active sites, adjusting electronic properties, enhancing metal carrier interactions, and changing their morphology. NTP provides an alternative option for catalysts in the modification processes of oxidation, reduction, etching, coating, and doping, especially for materials that cannot tolerate thermodynamic or thermosensitive reactions. This review will focus on applying NTP technology in bone implant material modification and analyze the overall performance of three common types of bone implant materials, including metals, ceramics, and polymers. The challenges faced by NTP material modification are also discussed.

5.
Anal Chem ; 2024 Sep 13.
Article in English | MEDLINE | ID: mdl-39269278

ABSTRACT

Discs and numerous other consumer products have been developed for point of care testing (POCT) to replace traditional large and expensive biochemical devices in certain scenarios. Herein, we propose a drip-dry strategy (2D strategy) assisted Blu-ray disc (BD) biosensor, termed BDB, for rapid and portable POCT within 30 min with the cost of a single test < $1. The platform utilizes the covered area formed by the deposition of the substance to be measured on the activated BD surface after the evaporation of water and realizes the quantitative detection of the target through the error readout of free disc quality diagnosis software. As a proof of concept, we first demonstrated the feasibility of direct quantitative detection of substances in solution in a single system through the detection of pure proteins avoiding colorimetric reagent used in traditional optical detection. For the complex mixed systems, we then innovatively utilize the principle that soluble targets promote/inhibit the dissolution of insoluble precipitates to achieve specific detection of targets and successfully apply BDB to the indirect quantitative detection of glutathione (GSH) with LOD of 0.447 mM in the range of 2-16 mM and organophosphorus pesticides (OPs) with LOD of 2.122 × 10-7 M in the range of 1.289 × 10-7-1.289 × 10-4 M. The BDB is widely applicable, easy to operate, and less time-consuming, which is anticipated to provide an alternative method for early, on-site detection or screening.

6.
Small ; : e2401848, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38940626

ABSTRACT

For every epidemic outbreak, the prevention and treatments in resource-limited areas are always out of reach. Critical to this is that high accuracy, stability, and more comprehensive analytical techniques always rely on expensive and bulky instruments and large laboratories. Here, a fully integrated and high-throughput microfluidic system is proposed for ultra-multiple point-of-care immunoassay, termed Dac system. Specifically, the Dac system only requires a handheld portable device to automatically recycle repetitive multi-step reactions including on-demand liquid releasing, dispensing, metering, collecting, oscillatory mixing, and discharging. The Dac system performs high-precision enzyme-linked immunosorbent assays for up to 17 samples or targets simultaneously on a single chip. Furthermore, reagent consumption is only 2% compared to conventional ELISA, and microbubble-accelerated reactions shorten the assay time by more than half. As a proof of concept, the multiplexed detections are achieved by detecting at least four infection targets for two samples simultaneously on a singular chip. Furthermore, the barcode-based multi-target results can rapidly distinguish between five similar cases, allowing for accurate therapeutic interventions. Compared to bulky clinical instruments, the accuracy of clinical inflammation classification is 92.38% (n = 105), with a quantitative correlation coefficient of R2 = 0.9838, while the clinical specificity is 100% and the sensitivity is 98.93%.

7.
Small Methods ; : e2400454, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38818744

ABSTRACT

In microbiological research, traditional methods for bacterial screening and antibiotic susceptibility testing are resource-intensive. Microfluidics offers an efficient alternative with rapid results and minimal sample consumption, but the demand for cost-effective, user-friendly platforms persists in communities and hospitals. Inspired by the Magdeburg hemispheres, the strategy adapts to local conditions, leveraging omnipresent atmospheric pressure for self-sealing of Rotation-SlipChip (RSC) equipped with a 3D circular Christmas tree-like microfluidic concentration gradient generator. This innovative approach provides an accessible and adaptable platform for microbiological research and testing in diverse settings. The RSC can avoid leakage concerns during multiple concentration gradient generation, chip-rotating, and final long-term incubation reaction (≥24 h). Furtherly, RSC subtypes adapted to different reactions can be fabricated in less than 15 min with cost less than $1, the result can be read through designated observational windows by naked-eye. Moreover, the RSC demonstrates its capability for evaluating bacterial biomarker activity, enabling the rapid assessment of ß-galactosidase concentration and enzyme activity within 30 min, and the limit of detection can be reduced by 10-fold. It also rapidly determines the minimum antibiotic inhibitory concentration and antibiotic combined medications results within 4 h. Overall, these low-cost and user-friendly RSC make them invaluable tools in determinations at previously impractical environment.

8.
Acta Pharmacol Sin ; 45(8): 1604-1617, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38589689

ABSTRACT

Heart failure with preserved ejection fraction (HFpEF) is closely associated with metabolic derangement. Sodium glucose cotransporter-2 inhibitors (SGLT2i) and glucagon-like peptide-1 receptor agonists (GLP-1RA) exert anti-HFpEF effects, but the underlying mechanisms remain unclear. In this study, we explored the anti-HFpEF effects of empagliflozin and liraglutide and the underlying molecular mechanisms in a mouse model of HFpEF. This model was established by high-fat diet (HFD) feeding plus Nω-nitro-L-arginine methyl ester (L-NAME) treatment. The mice were treated with empagliflozin (20 mg·kg-1·d-1, i.g.) or liraglutide (0.3 mg·kg-1·d-1, i.p.) or their combination for 4 weeks. At the end of the experimental protocol, cardiac function was measured using ultrasound, then mice were euthanized and heart, liver, and kidney tissues were collected. Nuclei were isolated from frozen mouse ventricular tissue for single-nucleus RNA-sequencing (snRNA-seq). We showed that administration of empagliflozin or liraglutide alone or in combination significantly improved diastolic function, ameliorated cardiomyocyte hypertrophy and cardiac fibrosis, as well as exercise tolerance but no synergism was observed in the combination group. Furthermore, empagliflozin and/or liraglutide lowered body weight, improved glucose metabolism, lowered blood pressure, and improved liver and kidney function. After the withdrawal of empagliflozin or liraglutide for 1 week, these beneficial effects tended to diminish. The snRNA-seq analysis revealed a subcluster of myocytes, in which Erbb4 expression was down-regulated under HFpEF conditions, and restored by empagliflozin or liraglutide. Pseudo-time trajectory analysis and cell-to-cell communication studies confirmed that the Erbb4 pathway was a prominent pathway essential for both drug actions. In the HFpEF mouse model, both empagliflozin and liraglutide reversed Erbb4 down-regulation. In rat h9c2 cells, we showed that palmitic acid- or high glucose-induced changes in PKCα and/or ERK1/2 phosphorylation at least in part through Erbb4. Collectively, the single-cell atlas reveals the anti-HFpEF mechanism of empagliflozin and liraglutide, suggesting that Erbb4 pathway represents a new therapeutic target for HFpEF. Effects and mechanisms of action of empagliflozin and liraglutide in HFpEF mice. HFpEF was induced with a high-fat diet and L-NAME for 15 weeks, and treatment with empagliflozin and liraglutide improved the HFpEF phenotype. Single nucleus RNA sequencing (snRNA-seq) was used to reveal the underlying mechanism of action of empagliflozin and liraglutide.


Subject(s)
Benzhydryl Compounds , Glucosides , Heart Failure , Liraglutide , Mice, Inbred C57BL , Signal Transduction , Sodium-Glucose Transporter 2 Inhibitors , Animals , Benzhydryl Compounds/pharmacology , Benzhydryl Compounds/therapeutic use , Glucosides/pharmacology , Glucosides/therapeutic use , Liraglutide/pharmacology , Liraglutide/therapeutic use , Signal Transduction/drug effects , Male , Mice , Heart Failure/drug therapy , Heart Failure/metabolism , Sodium-Glucose Transporter 2 Inhibitors/pharmacology , Sodium-Glucose Transporter 2 Inhibitors/therapeutic use , Diet, High-Fat , Stroke Volume/drug effects , Myocytes, Cardiac/drug effects , Myocytes, Cardiac/metabolism , Disease Models, Animal
9.
Anal Chem ; 96(18): 7145-7154, 2024 05 07.
Article in English | MEDLINE | ID: mdl-38656793

ABSTRACT

Immunoassays serve as powerful diagnostic tools for early disease screening, process monitoring, and precision treatment. However, the current methods are limited by high costs, prolonged processing times (>2 h), and operational complexities that hinder their widespread application in point-of-care testing. Here, we propose a novel centrifugo-pneumatic reciprocating flowing coupled with spatial confinement strategy, termed PRCM, for ultrafast multiplexed immunoassay of pathogens on a centrifugal microfluidic platform. Each chip consists of four replicated units; each unit allows simultaneous detection of three targets, thereby facilitating high-throughput parallel analysis of multiple targets. The PRCM platform enables sequential execution of critical steps such as solution mixing, reaction, and drainage by coordinating inherent parameters, including motor rotation speed, rotation direction, and acceleration/deceleration. By integrating centrifugal-mediated pneumatic reciprocating flow with spatial confinement strategies, we significantly reduce the duration of immune binding from 30 to 5 min, enabling completion of the entire testing process within 20 min. As proof of concept, we conducted a simultaneous comparative test on- and off-the-microfluidics using 12 negative and positive clinical samples. The outcomes yielded 100% accuracy in detecting the presence or absence of the SARS-CoV-2 virus, thus highlighting the potential of our PRCM system for multiplexed point-of-care immunoassays.


Subject(s)
COVID-19 , Centrifugation , SARS-CoV-2 , Immunoassay/methods , Immunoassay/instrumentation , SARS-CoV-2/isolation & purification , Centrifugation/instrumentation , COVID-19/diagnosis , COVID-19/virology , Humans , Microfluidic Analytical Techniques/instrumentation , Lab-On-A-Chip Devices
10.
Phys Chem Chem Phys ; 26(12): 9665-9674, 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38470042

ABSTRACT

Vacancy defects are commonly present in crystals of energetic materials, and significantly influence the structural stability and decomposition mechanisms. However, there is a lack of profound understanding regarding the introduction of vacancy defects in energetic ionic salt, dihydroxylammonium 5,5'-bitetrazole-1,1'-dioxide (TKX-50). Due to the 1 : 2 ratio of anions to cations, TKX-50 possesses a more complex distribution of vacancy defects compared to traditional energetic materials. Based on the density functional theory method, the relatively favorable thermodynamic formation of vacancy defect distributions was revealed. The noncovalent interactions within the system, as well as the planarity of the anions, were investigated to understand the structural stability of TKX-50. Through ab initio molecular dynamics simulations, we discovered that vacancy defects can expedite the proton transfer during the initial decomposition stage of TKX-50 and affect the pathways of proton transfer. In the subsequent decomposition process, introduction of vacancy defects in the TKX-50 crystal leads to an earlier onset of ring-opening reactions and accelerates the appearance of decomposition products. The findings have the potential to provide insights into modeling vacancy defects in energetic ionic salts and reveal the impact of such defects on the structural stability and decomposition mechanisms of these materials.

11.
Nat Chem ; 16(7): 1101-1112, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38499848

ABSTRACT

Phase separation inside mammalian cells regulates the formation of the biomolecular condensates that are related to gene expression, signalling, development and disease. However, a large population of endogenous condensates and their candidate phase-separating proteins have yet to be discovered in a quantitative and high-throughput manner. Here we demonstrate that endogenously expressed biomolecular condensates can be identified across a cell's proteome by sorting proteins across varying oligomeric states. We employ volumetric compression to modulate the concentrations of intracellular proteins and the degree of crowdedness, which are physical regulators of cellular biomolecular condensates. The changes in degree of the partition of proteins into condensates or phase separation led to varying oligomeric states of the proteins, which can be detected by coupling density gradient ultracentrifugation and quantitative mass spectrometry. In total, we identified 1,518 endogenous condensate proteins, of which 538 have not been reported before. Furthermore, we demonstrate that our strategy can identify condensate proteins that respond to specific biological processes.


Subject(s)
Biomolecular Condensates , Proteome , Proteome/metabolism , Proteome/chemistry , Humans , Biomolecular Condensates/chemistry , Biomolecular Condensates/metabolism , High-Throughput Screening Assays , Mass Spectrometry , HeLa Cells , Proteomics/methods
12.
Biosens Bioelectron ; 255: 116240, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38554576

ABSTRACT

Public health events caused by pathogens have imposed significant economic and societal burdens. However, conventional methods still face challenges including complex operations, the need for trained operators, and sophisticated instruments. Here, we proposed a fully integrated and automated centrifugal microfluidic chip, also termed IACMC, for point-of-care multiplexed molecular diagnostics by harnessing the advantages of active and passive valves. The IACMC incorporates multiple essential components including a pneumatic balance module for sequential release of multiple reagents, a pneumatic centrifugation-assisted module for on-demand solution release, an on-chip silicon membrane module for nucleic acid extraction, a Coriolis force-mediated fluid switching module, and an amplification module. Numerical simulation and visual validation were employed to iterate and optimize the chip's structure. Upon sample loading, the chip automatically executes the entire process of bacterial sample lysis, nucleic acid capture, elution quantification, and isothermal LAMP amplification. By optimizing crucial parameters including centrifugation speed, direction of rotation, and silicone membrane thickness, the chip achieves exceptional sensitivity (twenty-five Salmonella or forty Escherichia coli) and specificity in detecting Escherichia coli and Salmonella within 40 min. The development of IACMC will drive advancements in centrifugal microfluidics for point-of-care testing and holds potential for broader applications in precision medicine including high-throughput biochemical analysis immune diagnostics, and drug susceptibility testing.


Subject(s)
Biosensing Techniques , Mycobacterium tuberculosis , Nucleic Acids , Microfluidics , Point-of-Care Systems , Microbial Sensitivity Tests , Pathology, Molecular , Nucleic Acid Amplification Techniques/methods , Point-of-Care Testing , Nucleic Acids/analysis , Escherichia coli , Lab-On-A-Chip Devices
13.
Analyst ; 149(4): 1250-1261, 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-38225883

ABSTRACT

Exosomal microRNAs (miRNAs) play a pivotal role in intercellular communication, regulating gene expression in target cells, and hold significant promise as cancer biomarkers for early detection and screening. However, achieving precise and viable detection of exosomal miRNAs remains a challenge. This paper proposes an all-in-one detection strategy for breast cancer-derived exosomal miRNA-21 on a pen-based paper chip (PPC). The PPC is constructed using a modified automatic pen and lateral flow assay (LFA), which results in a cost-effective fabrication process. The user only needs to add the sample and trigger the top of the self-contained PPC after a period of time to complete the entire detection process. To enhance the sensitivity of exosomal miRNA testing, an enzyme-free catalyzed hairpin assembly (CHA) is further introduced, enabling highly sensitive detection of miRNA-21 with a limit of detection (LOD) of 25 fmol. Additionally, the detection of miRNAs in differentially-expressed cells and clinical samples has also been successfully achieved with high specificity. Overall, the proposed PPC provides an effective tool for detecting early cancer, monitoring diseases, and establishing point of care testing (POCT).


Subject(s)
Biosensing Techniques , Breast Neoplasms , Exosomes , MicroRNAs , Humans , Female , MicroRNAs/genetics , Breast Neoplasms/diagnosis , Breast Neoplasms/genetics , Biosensing Techniques/methods , Limit of Detection , Exosomes/genetics
14.
Talanta ; 269: 125398, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-37979508

ABSTRACT

Due to the ever-increasing challenge of emerging and reemerging infections on global health, the development of POCT tools has been propelled. However, conventional point-of-care testing methods suffer from several limitations, including cumbersome operation, long detection times, and low accuracy, which hamper their widespread application. Compared to traditional disease diagnostic equipment, mobile health platforms offer several advantages, including portability, ease of operation, and automated analysis of detection results through recognition algorithms. Consequently, they hold great promise for the future. Here, we developed a smartphone-based centrifugal mHealth platform implementing daisy-shaped quick response chip for hematocrit measurement. The centrifugal microfluidic chip is combined with a smartphone through a back-clip-on mobile phone adapter whose control circuit is designed with low power consumption to enable the platform to operate without requiring a high-power source that is inconvenient to carry, thereby achieving the goal of portability. Concurrently, we designed a quick response chip featuring a unique hollow daisy structure that is in line with the properties of hematocrit detection. The distinctive configuration of the chip enables adequate centrifugal force to be supplied for hematocrit detection. Additionally, our customized quick response code recognition algorithm is able to recognize this chip, facilitating non-experts in performing hematocrit intelligent recognition with their smartphones.


Subject(s)
Smartphone , Telemedicine , Hematocrit , Equipment Design , Microfluidics
15.
Small ; : e2310206, 2023 Dec 12.
Article in English | MEDLINE | ID: mdl-38085133

ABSTRACT

Point-of-care testing (POCT) is experiencing a groundbreaking transformation with microfluidic chips, which offer precise fluid control and manipulation at the microscale. Nevertheless, chip design or operation for existing platforms is rather cumbersome, with some even heavily depending on external drivers or devices, impeding their broader utilization. This study develops a unique programmable gravity self-driven microfluidic chip (PGSMC) capable of simultaneous multi-reagent sequential release, multi-target analysis, and multi-chip operation. All necessary reagents are introduced in a single step, and the process is initiated simply by flipping the PGSMC vertically, eliminating the need for additional steps or devices. Additionally, it demonstrates successful immunoassays in less than 60 min for antinuclear antibodies testing, compared to more than 120 min by traditional methods. Assessment using 25 clinically diagnosed cases showcases remarkable sensitivity (96%), specificity (100%), and accuracy (99%). These outcomes underscored its potential as a promising platform for POCT with high accuracy, speed, and reliability, highlighting its capability for automated fluid control.

16.
Anal Chem ; 95(33): 12521-12531, 2023 08 22.
Article in English | MEDLINE | ID: mdl-37556853

ABSTRACT

There remains an unmet need for a fully integrated microfluidic platform that can automatically perform multistep and multireagent immunoassays. Here, we proposed a novel online dual-active valve-based centrifugal microfluidic chip, termed DAVM, for fully automatic point-of-care immunoassay. Practically, the puncture valve, one of the dual active valves, is capable of achieving precise, on-demand, sequential release of prestored reagents, while the other valve-reversible active valve enables controlled retention and drainage of the reaction solutions. Thereby, our technology mitigates the challenges of hydrophilic/hydrophobic modifications and unstable valve control performance commonly observed in passive valve controls. As a proof of concept, the indirect enzymatic immunoblotting technique was employed on DAVM for fully automated immunological analysis of eight targets, yielding outcomes within an hour. Furthermore, we conducted a comparative analysis of 28 clinical samples with autoimmune diseases. According to 224 clinical data, the sample testing concordance rate between DAVM and the traditional instrument was 82%, with a target compliance rate of 97%. Therefore, our DAVM system has powerful potential for fully automated immunoassays.


Subject(s)
Microfluidic Analytical Techniques , Microfluidics , Point-of-Care Systems , Lab-On-A-Chip Devices , Immunoassay/methods , Immunoblotting
17.
J Biochem Mol Toxicol ; 37(12): e23508, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37623816

ABSTRACT

Wogonin (5,7-dihydroxy-8-methoxyflavone), a natural flavonoid compound in herbal plants, can suppress growth in hepatocellular carcinoma (HCC). However, the microRNA (miRNA) expression profiles that are influenced by wogonin have not been thoroughly described. To explore the novel miRNAs and the biological mechanism underlying the effect of wogonin on HCC cells. The effect of wogonin on Huh7 cell growth was assessed both in vitro and in vivo. The expression profiles of miRNAs were obtained by small RNA sequencing. Luciferase reporter experiment and bioinformatics analysis were conducted to determine whether tyrosine 3-monooxygenase/tryptophan 5-monooxygenase activation protein zeta (YWHAZ) can bind to miR-27b-5p. Effects of the ectopic expression of YWHAZ and miR-27b-5p on Huh7 cells proliferation and apoptosis were evaluated. Furthermore, the cell cycle, apoptosis and multiple signaling pathway-related molecules were detected by Western blot analysis. Wogonin substantially inhibited the growth of Huh7 cells both in vitro and in vivo. Seventy miRNAs exhibited greater than twofold changes in wogonin-treated cells. Upregulation of miR-27b-5p inhibited Huh7 cell proliferation, and the anticancer effect of wogonin was reversed after miR-27b-5p knockdown. miR-27b-5p directly targeted YWHAZ in HCC cells. The proliferation-inhibiting effect of miR-27b-5p was revoked by YWHAZ overexpression. Meanwhile, inhibition of HCC growth was achieved by downregulating YWHAZ. Wogonin exerted antitumor activity through multiple signaling molecules, such as focal adhesion kinase, protein kinase B, mammalian target of rapamycin and molecules related to apoptosis and cell cycle by upregulating miR-27b-5p and downregulating YWHAZ. Our findings suggest that miR-27b-5p/YWHAZ axis contributes to the inhibitory effect of wogonin in HCC by targeting related genes and multiple signaling pathways.


Subject(s)
Carcinoma, Hepatocellular , Liver Neoplasms , MicroRNAs , Humans , Carcinoma, Hepatocellular/drug therapy , Carcinoma, Hepatocellular/genetics , Carcinoma, Hepatocellular/metabolism , Liver Neoplasms/drug therapy , Liver Neoplasms/genetics , Liver Neoplasms/metabolism , Cell Line, Tumor , MicroRNAs/genetics , MicroRNAs/metabolism , Cell Proliferation/genetics , Gene Expression Regulation, Neoplastic , Cell Movement/genetics , 14-3-3 Proteins/genetics , 14-3-3 Proteins/metabolism
18.
Nat Commun ; 14(1): 1341, 2023 03 11.
Article in English | MEDLINE | ID: mdl-36906581

ABSTRACT

The frequent outbreak of global infectious diseases has prompted the development of rapid and effective diagnostic tools for the early screening of potential patients in point-of-care testing scenarios. With advances in mobile computing power and microfluidic technology, the smartphone-based mobile health platform has drawn significant attention from researchers developing point-of-care testing devices that integrate microfluidic optical detection with artificial intelligence analysis. In this article, we summarize recent progress in these mobile health platforms, including the aspects of microfluidic chips, imaging modalities, supporting components, and the development of software algorithms. We document the application of mobile health platforms in terms of the detection objects, including molecules, viruses, cells, and parasites. Finally, we discuss the prospects for future development of mobile health platforms.


Subject(s)
Microfluidics , Smartphone , Humans , Artificial Intelligence , Point-of-Care Testing , Software
19.
Talanta ; 258: 124466, 2023 Jun 01.
Article in English | MEDLINE | ID: mdl-36963148

ABSTRACT

This paper proposed a hand-powered centrifugal micropipette-tip strategy, termed HCM, for all-in-one immunoassay combined with a distance-based readout for portable quantitative detection of SARS-CoV-2. The target SARS-CoV-2 virus antigen triggers the binding of multiple monoclonal antibody-coated red latex nanobeads, forming larger complexes. Following incubation and centrifugation, the formed aggregated complexes settle at the bottom of the tip, while free red nanobeads remain suspended in the solution. The HCM enables sensitive (1 ng/mL) and reliable quantification of SARS-CoV-2 within 25 min. With the advantages of free washing, free fabrication, free instrument, and without the optical device, the proposed low-cost and easy-to-use HCM immunoassay shows great potential for quantitative POC diagnostics for SARS-CoV-2.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , Immunoassay
20.
Anal Chem ; 95(14): 6145-6155, 2023 04 11.
Article in English | MEDLINE | ID: mdl-36996249

ABSTRACT

Low-cost, rapid, and accurate acquisition of minimum inhibitory concentrations (MICs) is key to limiting the development of antimicrobial resistance (AMR). Until now, conventional antibiotic susceptibility testing (AST) methods are typically time-consuming, high-cost, and labor-intensive, making them difficult to accomplish this task. Herein, an electricity-free, portable, and robust handyfuge microfluidic chip was developed for on-site AST, termed handyfuge-AST. With simply handheld centrifugation, the bacterial-antibiotic mixtures with accurate antibiotic concentration gradients could be generated in less than 5 min. The accurate MIC values of single antibiotics (including ampicillin, kanamycin, and chloramphenicol) or their combinations against Escherichia coli could be obtained within 5 h. To further meet the growing demands of point-of-care testing, we upgraded our handyfuge-AST with a pH-based colorimetric strategy, enabling naked eye recognition or intelligent recognition with a homemade mobile app. Through a comparative study of 60 clinical data (10 clinical samples corresponding to six commonly used antibiotics), the accurate MICs by handyfuge-AST with 100% categorical agreements were achieved compared to clinical standard methods (area under curves, AUCs = 1.00). The handyfuge-AST could be used as a low-cost, portable, and robust point-of-care device to rapidly obtain accurate MIC values, which significantly limit the progress of AMR.


Subject(s)
Anti-Bacterial Agents , Microfluidics , Microfluidics/methods , Anti-Bacterial Agents/pharmacology , Microbial Sensitivity Tests , Escherichia coli , Ampicillin
SELECTION OF CITATIONS
SEARCH DETAIL